ANALYSIS OF FLAT PLATE PHOTOVOLTAIC-THERMAL (PVT) MODELS

Size: px
Start display at page:

Download "ANALYSIS OF FLAT PLATE PHOTOVOLTAIC-THERMAL (PVT) MODELS"

Transcription

1 ANALYSIS OF FLAT PLATE PHOTOVOLTAIC-THERMAL (PVT) MODELS J. Bilbao and A. B. Sproul School of Photovoltaic and Renewable Energy Engineering University of New South Wales Kensington, NSW 52, Australia ABSTRACT In this work the performance of four PVT water models were compared: the default TRNSYS PVT model Type50, a modified version of the same model (Type50-C), a new model (Type850) developed using analytical solutions and the empirical relation presented by Akhtar and Mullick [11] to calculate the cover temperature in flat plate collectors, and a double iteration numerical model. A detailed analysis and comparison between all four models was carried out to identify specific errors, and Type50 and Type850 were also compared based on the annual thermal and electrical yields of a PVT residential system using TMY2 data. Results show that errors from some models can be as high as 6 under specific conditions, and close to 1 for annual yield figures. Key words: Photovoltaic-Thermal, PVT, Modeling, 1. INTRODUCTION Within TRNSYS 16, the default model for PVT systems simulations is Type50, which is based on the Florschuetz [1] model to simulate the performance of PVT water systems. In essence, it is an extension of the Hottel-Whillier [2] model for flat plate collectors. Type50 also incorporates the empirical expression for heat losses developed by Klein [3] in conjunction with the convection loss coefficient suggested by McAdams [4]. This is more or less the standard Duffie and Beckman approach [5] which has been widely used for the last 30 years. Today, more accurate models and empirical expressions exist. Charalambous et al [6] was the first to present a review of the literature available for PVT systems, covering existing analytical and numerical models, simulations and experimental work. Later, Zondag presented a complete review [7] of PVT technology, including models developed. In summary, most of the early work on PVTs developed analytical models based on the Hottel-Whillier [2] model for flat plate collectors. According to Charalambous Florschuetz modified the Hottel Willier analytical model for flat plate collectors so all existing expressions and information available in the literature (such as the collector efficiency factor, F and the heat removal factor, F r ) still apply. Bergene and Løvvik [8] found that their model (a more detailed version of the Hottel-Willier model) was able to predict PVT system efficiencies well, but they could not compare their results to experimental data as system parameters were missing in the available literature. Sandnes and Rekstad [9] found a good level of agreement with their experimental results. Zondag et al [10] developed and compared four numerical models, a 3D dynamical model, and 3D, 2D and 1D static models. He found that all the models simulate the PVT system efficiency within 5% error of the experimental data, and that the 1D model, based on Hottel Whillier and Klein equations, was well suited for annual yield studies, mainly for its computational speed. Although, annual yield figures for a domestic PVT system were reported, they were obtained by using the 1D model, and no comparison with the more accurate numerical models was carried out. It could be concluded from the literature that Klein s equation gives a reasonable approximation for steady state models, with an adequate agreement with experimental 1

2 data. However, Klein s equation has not been tested against annual yield results using experimental data or other models. Moreover, according to Akhtar and Mullick [11], Klein s equation can produce errors of up to 1 in the estimation of the top losses of a flat plate collector for high plate temperatures, and around 5% for low plate temperatures. In the same publication, Akhtar and Mullick propose a new experimental relation to estimate the cover temperature of a flat plate hot water system, in replacement of Klein s equation. The objective of this work was to check the results of different PVT models for collectors with and without a cover. The analysis is focused on heat transfer from the top surfaces of the collector, and therefore is relevant not just for PVT water models but also PVT air. Particular attention was paid to the performance of the standard model included in TRNSYS, Type50 (and therefore Florschuetz and Klein approach), against more accurate models, like the developed Type850. Section two of this paper will describe in detail all the models used in the work. In section three, the results of several simulations between the models are presented, including in-depth comparisons. Finally, in section four, several conclusions and recommendations are provided. The nomenclature is presented in section five. 2. DESCRIPTION OF PVT MODELS USED A total of four PVT models were used in this work: 1) a numerical model using a double iteration solving method of the heat transfer equations; 2) a numerical model, with a single iteration process, where the cover temperature is calculated using the relations developed by Akhtar and Mullick (Type850); 3) Type50 model (part of the standard TRNSYS software package); 4) a modified version of Type50, in which F is calculated for each simulation (called Type50-C). All of the above models were implemented in Excel. These models can generate quick steady state results under particular conditions, and are used for detailed comparison between the models, but are not suited for year long simulations. In order to study the effects of the approximations made in Type50 on an annual yield basis, model number 2, called Type850 from now onwards (work of the authors), was also implemented in TRNSYS, due to its simplicity and good accuracy when compared to the double iteration numerical model (model number 1). 2.1 Double iteration numerical model (implemented in Excel) As its name implies, in this numerical model a double iteration is required to calculate all the heat transfer equations for the case of the PVT collector with cover. First, the initial cover and absorber plate temperatures are set: for the cover temperature the ambient temperature plus one degree is used, and 100 C is used for the plate temperature, which is close to the stagnation temperature. With T p and T c, the Nusselt number of the air in the cavity is estimated using Buchberg [12] relation, in order to calculate the convection losses between both surfaces. Also, from Cooper [13] the relations from the Tables of Thermal Properties of Gases, U.S. Department of Commerce, were used to model the property of the air in the cavity between the plate and cover, according to the average temperature of both surfaces. Then all the convective and radiative losses are calculated and combined as per equation 1, in order to estimate the total losses of the PVT module. (1) [( ) ( ) ] where U rpc and U cpc are the radiative and convective losses between the plate and the cover, U rcs and U w are the radiative and convection losses of the top cover, and U BE is the back and edge losses, constant during the simulation. Then, the thermal efficiency factors are calculated, starting by F, using the equation for collectors with square channels: (2) where h f is the total thermal conductance between the plate and the fluid. F r is calculated using the standard equation in [5]. Then the electrical and thermal useful energy rates per unit of area are calculated using: (3) [ ( )] (4) ( ( )) Notice that for the thermal energy output, the absorbed solar energy is corrected using the electrical energy produced by the PV cells. The mean plate temperature and the cover temperature are calculated using an energy balance approach: (5) In the following sections all the models will be described in more detail. (6) ( ) ( ) ( ) 2

3 From this point onwards, the new values of T p or T c can be used to recalculate all the equations until the chosen variables converge. Then the same process can be used with the other variable until it converges. This double iteration process will have to be repeated until the error in both variables is small. If done manually it can be a lengthy process, but in excel the solver routine can be used, and solutions are found automatically. For the case of the PVT collector without a cover, there is no need to estimate the cover temperature and a single iteration approach is enough to accurately calculate all the heat losses. The simulation starts with an initial estimation of the plate temperature. Then, the total losses (U L ) are calculated by adding the radiation (U rcs ) and convection (U w ) losses from the top of the panel, plus the back and edge losses (U BE ). Once the losses are calculated, the same equations used for the collector with a cover (Eqs. 2, 3, 4, and 5) are used to calculate F, F r, Q e, Q u, and T p, but the cover temperature is replaced by the plate temperature when required. 2.2 Single iteration model, TYPE850 (implemented in Excel and TRNSYS) In this model, the empirical relations developed by Akhtar and Mullick [11] to estimate the cover temperature of Flat Plate Solar Collectors were used. One of the strengths of these empirical relations is that they allow for the use of the Sky Temperature, and therefore, the correct calculation of the radiation losses. The algorithm and equations used in this model are exactly the same as in the double iteration model, except for the use of the cover temperature equations. This allows having one less unknown variable and therefore, only a single iteration process can be used. This iteration allows for the selfcorrection of the thermal energy output (eq. 4) and U L, so there is no need to use Florschuetz s proposed adjustment for PVT panels. This also allows the use of Akhtar and Mullick equations without the need of any modifications. For the case of the PVT collector without a cover, the algorithm and equations are the same as for the first model. 2.3 Standard PVT model, Type50 (implemented in Excel, existing in TRNSYS) As explained above, Type50 is a very close implementation of Florschuetz [1] work. Type50 has four modes of operation for flat plate collectors, and other modes for concentrating collectors not reviewed in this paper. In this work, MODE 2 will be used because it proved to be more stable than the others. However, in MODE 2 the angular dependence of the cover transmisivity is considered constant (unlike MODE4 which includes the incident angle modifiers, but was unable to converge), so adjustments were introduced to the solar irradiance data to take into account the angle of incidence to make a fair comparison with the rest of the models. Type 50 also uses a single iteration approach to solve the heat transfer equations, thanks to the use of Klein s equation to estimate the top cover losses. Some key Type50 model details and differences with the original Florschuetz work are: - The algorithm runs for three iterations (controlled by an internal counter) for each time step, after which the program exits the simulation with whatever values are achieved. - Equations for the calculation of F were not implemented in Type50, as F is a given parameter to the model and remains constant through the whole simulation. - The mean fluid temperature is approximated as the average of the inlet and outlet temperature, which is different to the true analytical value. - The cell temperature is calculated at the end of each time step and is used only for output purposes and not as part of the internal calculations. - The thermal losses are calculated using the empirical equation developed by Klein [3], which does not take into account the sky temperature - In the implementation of Klein s equation in Type50, the mean water temperature is used instead of the mean plate temperature. In the Excel implementation of this model, the three iterations limit was not used, and the algorithm runs until the values converge. 2.4 Modified Standard PVT model, Type50-C (implemented in Excel) This type uses the same equations as Type50, but F is calculated using equation 2 for each simulation. This allows an accurate value of the efficiency factor to be calculated depending on the calculated heat losses. Although this is certainly an improvement over Type50, it also makes the model more susceptive to the possible errors introduced in the calculation of the top losses by Klein s equation. 3. RESULTS In the first three parts of this section, all the models using empirical equations (models 2 to 4) are compared in detail against the double iteration numerical model (model 1), studying for example the impact of the simplifications made 3

4 Tamb ( C) Tamb ( C) in Type50, particularly, the use of the constant F coefficient. For the purpose of these comparisons, the Excel implementations of the models were used, with the parameters at design conditions, shown in Table 1. TABLE 1: PARAMETERS AT DESIGN CONDITIONS FOR THE CALCULATION OF F Value Value Parameter No Cover Cover Description H Solar Radiation (W/m 2 ) V w 2 2 Wind velocity (m/s) T in Inlet Temperature ( C) T amb Amb. Temperature ( C) B Panel Tilt (degrees) ε p Collector Plate Emissivity ε g Glass cover Emissivity α Effective Absorptance τ Total Transmittance η r Cell Eff. at Ref. Temp. β r Cell Temp. Coef. (1/K) ů Mass Flowrate (Kg/s.m 2 ) h f Plate to Fluid (W/m 2.C) U L Total Losses (W/m 2.C) F Collector Eff. Factor In part 3.4 of this section, Type50 and Type850 are compared on an annual basis, using a simulation of a residential hot water system in TRNSYS. 3.1 Effects of F simplification F was calculated at the design conditions (see Table 1) and kept constant in Type50, but it was calculated for each simulation in Type50-C. The value of F r was compared for both models to quantify the errors of the simplification, because is directly proportional to the useful thermal energy Q u. Results for different combinations of ambient temperature, inlet temperature and wind velocity are shown in Figure 1 and Figure 2 respectively, for both type of collectors (with and without a cover). For the panel without a cover, changes in the wind speed have an important impact in the calculation of F r, so the changes in the inlet and ambient temperatures are dwarfed in comparison. This is a logical result, because convection losses are dominant in a coverless panel. When the panel operates close to the design conditions, the errors are small and less than 5%, but at high wind speeds errors can escalate up to 3. The problem of Klein s equation for coverless panels as implemented in Type50, is the use of the mean fluid temperature instead of the correct mean plate temperature. The effects of a constant F are less pronounced in PVT modules with a cover, as the maximum a) F r percentage error (T amb = T sky = C, N = 0) % % 24-5% % -15%--1 -%--15% 18-25%--% % -35% Wind Velocity (m/s) b) F r percentage error (T amb = T sky = C, N = 1) %-3% 45 1%-2% -1% 40-1%- 35-2%--1% 30-3%--2% 25-4%--3% -5%--4% 15-6%--5% Wind Velocity (m/s) Fig. 1: F r percentage error for fixed ambient temperature a) F r percentage error (T in = C, N = 0) % % 24-5% % -15%--1 -%--15% 18-25%--% % -35% Wind Velocity (m/s) b) F r percentage error (T in = C, N = 1) % % 0.5% % -0.5% % -1.5% % % % Wind Velocity (m/s) Fig. 2: F r percentage error for fixed inlet temperature. 4

5 (W/m2) (W/m2) error is kept below 6%. In this case, the inlet temperature is shown to have an equally important effect to the wind velocity. The results suggest that the effects of using a fixed F are reasonable for a PVT system with a cover. 3.2 Comparison of Type50, 50-C, and 850 against Model 1 Klein s equation is close to the correct calculation of top losses when ambient temperature is similar to sky temperature (cloudy sky), so Type50 should perform well under these conditions. However, PVT panels have high emissivity unlike solar hot water collectors that usually have selective surfaces so it s expected that changes in the sky temperature will produce noticeable effects in the performance of the models even for panels with covers. The model using Akhtar and Mullick equations was also included. Figure 3 shows the errors for q u and Figure 4 for U L, for PVT panels with (N=1) and without (N=0) cover. For this set of simulations all the parameters were kept at the design conditions (best case scenario for Type50), except for the inlet temperature. From Figure 3 and Figure 4 we can conclude that: - The levels of error for Type50-C are close to zero for cloudy sky conditions, and independent of wind velocity and inlet temperature. In clear sky conditions, the errors are limited to 50 W/m 2. - Type50 does not perform well in the calculation of q u, resulting in errors above 150 W/m 2, for clear and cloudy skies. The use of a fixed F has an undesirable large impact in this case. - In the calculation of U L, both models, Type50 and Type50-C, have considerable errors except for the panel without a cover and cloudy skies. In all other cases, the errors are significant - Because the thermal losses are underestimated, the useful thermal energy for both models, Type50 and Type50-C, were overestimated, although the corrected model has consistently smaller errors. - The model using Akhtar and Mullick equations does remarkably well, with errors well below 5% for U L and under 1 to 2 W/m 2 for q u, which is a big improvement over Type50. The correction factor proposed by Florschuetz [1] can account for up to 5% of difference in the calculation of U L. When using iterative methods, the extra correction leads to a under prediction of U L and over prediction of the useful thermal output. The results show that the biggest limitation of Type50 is the implementation of Klein s equation, as even Type50-C, using correct F values can produce errors as high as 7% at the design conditions, and up to 17% in the worst cases. 3.3 Performance under stagnation It s important to study no flow conditions in a PVT system, more than in a normal flat plate collector, because the temperatures reached in the plate affect the electric performance. Therefore, it is imperative for a PVT model to estimate as accurately as possible the stagnation temperatures % -% -25% -3-35% -4-45% -5-55% a) q u absolute error (Wv=2m/s, Ta= C, N=0) Type50-C, Ts=Ta Type50, Ts=Ta Type50-C, Ts=Ta-18 Type50, Ts=Ta-18 b) q u absolute error (Wv=2m/s, Ta= C, N=1) A&M, Ts=Ta Type50-C, Ts=Ta Type50, Ts=Ta A&M, Ts=Ta-18 Type50-C, Ts=Ta-18 Type50, Ts=Ta-18 Fig. 3: q u absolute error compared to numerical model. 5% -5% a) U L percentage error (Wv=2m/s, Ta= C, N=0) Type50-C, Ts=Ta Type50, Ts=Ta Type50-C, Ts=Ta-18 Type50, Ts=Ta-18 b) U L percentage error (Wv=2m/s, Ta= C, N=1) 5% -5% -1-15% -% -25% -3-35% -4-45% -5-55% A&M, Ts=Ta Type50-C, Ts=Ta Type50, Ts=Ta A&M, Ts=Ta-18 Type50-C, Ts=Ta-18 Type50, Ts=Ta-18 Fig. 4: U L percentage error compared to numerical model. 5

6 (W/m2) (W/m2) a) q e absolut error (Wv=2m/s, Ta= C, N=0) connected to a 300 liter electric boosted hot water tank, with a set point of 60 C. The electric output of the PV array is assumed to be always at the maximum power point, and no losses in the inverter or cables have been incorporated. For both models a PVT panel of 1.28m 2 was used, with an electrical efficiency of 14% at STC. The size and the electrical efficiency of the PVT panel are similar to commercially available PV panels Type50, Ts=Ta Type50, Ts=Ta b) q e absolute error (Wv=2m/s, Ta= C, N=1) -5% -1-15% -% -25% -3 a) Q aux percentage error (18 panels) A&M, Ts=Ta Type50, Ts=Ta A&M, Ts=Ta-18 Type50, Ts=Ta-18 Fig. 5: q e absolute error compared to numerical model in stagnation conditions. Depending on the size of the system, and its operation and controls, it is probable that a PVT system will spend several hours in stagnation during summer. Figure 5 shows the results for the error in the calculation of the electric output per unit of area, for different wind, inlet temperature (needed for the calculation T mf and of U L in Klein s equation), and sky temperature under stagnation. As can be seen, Type50 tends to underestimate the electrical output under stagnation conditions; which will suggest an overestimation in the plate temperatures. This agrees with the results reported by the ECN [14]. Errors in the collector without a cover are generally small. For the collector with a cover, errors are more important and close to 1 under design conditions or around 7 (W/m2). The model using Akhtar and Mullick equations again performs well. 3.4 Annual Yields Comparison in TRNSYS In this section, the thermal and electrical annual yield of a residential PVT system located in Sydney, Australia, are presented. The system was simulated using TRNSYS, with two different PVT models: Type50, and Type 850. The simulation models the energy requirements of a standard four person residence in the Sydney climate. The annual hot water energy consumption is estimated to be 2,709 kwh, or 7.4 kwh/day, and the annual electric energy usage is estimated as 8,249 kwh, or 22.6 kwh/day (total daily energy consumption of 30kWh); figures derived from DEWHA and IPART reports [15-16]. The PVT system is -35% Flow Rate (Kg/s.m2) Sydney - No Cover Melbourne - No Cover Sydney - With Cover Melbourne - With Cover 6% 4% 2% -2% -4% -6% -8% b) Q pv percentage error (18 panels) Flow Rate (Kg/s.m2) Sydney - No Cover Melbourne - No Cover Sydney - With Cover Melbourne - With Cover 6% 4% 2% -2% -4% -6% -8% c) Q net percenatge error (18 panels) Flow Rate (Kg/s.m2) Sydney - No Cover Melbourne - No Cover Sydney - With Cover Melbourne - With Cover Fig. 6: annual yield percentage error for different parameters and climates, Type50 against Type850. A system of 3,240Wp comprised of 18 panels was chosen to simulate a typical system, similar to what would be installed on a house rooftop. Two scenarios were used, systems with and without a cover. All the parameters are kept equal between both models and scenarios. Results of the errors between Type 50 and Type 850 are presented in Figure 6: auxiliary energy (Q aux ), the electrical energy (Q pv ), pump energy (Q pump ), and the net energy (Q net ) defined as Q net = (Q load - Q aux ) + Q pv - Q pump. 6

7 The results show that Type50 is consistently over predicting the thermal output, and therefore, the auxiliary energy required is under predicted with respect to Type 850. Errors for the annual amount of required auxiliary energy are around 15% for panels with cover and 6% for panels without a cover. On the electrical output, Type50 with a cover under predicts the annual yield by 7% and over predicts the panel without a cover by 3%, i.e., Type50 with cover runs hotter than Type850, and Type50 without a cover runs cooler. The energy required by the pump is in direct relation of the amount of hours that the thermal system was working. In this scenario, Type50 with and without a cover runs the pump 7% and % longer time frames, respectively. Some findings might seem contradictory, but in reality, they reflect how a PVT system performance changes depending on the size of the system, its operation, and in particular, if it was carried out as an individual unit or as part of a system. This reaffirms the point that PVT systems performance and design should be always analyzed in the context of an application. 4. CONCLUSIONS From the specific analysis of Type50, we can summarize the shortcomings of the model as: - The value of F is assumed as a constant parameter, independent of the changes in the total losses U L which depends on ambient conditions (wind speed, ambient temperature) and fluid temperature. Errors of up to 1 are expected when maintaining F constant. - Sky temperature is not used for the calculation of radiation losses. This is particularly important in PVT systems, compared to hot water collectors, because PV panels have high emissivity. - The model implements the original equation of Klein [3] using T mf instead of T p. This leads to more errors and instabilities when T mf < T amb. For PVT systems with small areas, this is not an uncommon scenario (Akhtar and Mullick equation has the same problem when T p < T amb, less often). - The model uses Florschuetz s correction factor for U L to account for the electrical output of the system. However, it is considered that this correction factor should not be used. - As a result, Type50 calculation of U L can produce errors of up to 6 in the worst cases. - Although 3 iterations should be enough for the model to converge most of the times, there is no guarantee that moderate errors could not be happening in some time steps. From the annual yield analysis we can conclude that: - Even though the errors are in general smaller than in the specific analysis, some serious differences are still present, specifically regarding the thermal output and its effect in the auxiliary power, with maximum errors of 16% for Sydney climate and 32% for Melbourne climate. - Type50 underestimates the thermal losses of the panel and therefore the model overestimates the thermal output. This results in the controller running the pump more hours during the year, which leads to large errors in the calculations of the annual energy required by the pump system. - PV electric energy output errors are of the order of ±5%, which can be considered acceptable. - As for any summary of data, the annual yield gives an average of the errors, possibly masking large differences in the operation of the system in a day to day basis. In conclusion, it appears clear that Type50 offers several limitations where high levels of accuracy are required. Although the electrical output accuracy is worrying at a model level, the errors in the annual yield case are acceptable. The errors on the thermal output can be above 1, which introduces a higher level of uncertainty in the design of a system. On the other hand, the work proposed by Akhtar and Mullick [7] proved to be exceptionally accurate when compared to the complete numerical solution. Finally, it is recommended that system analyses with whole year simulations (using TMY2 data or similar) should be used to study the performance of PVT systems and to compare different models. 5. NOMENCLATURE B tilt angle of panel F collector efficiency factor F r collector heat removal factor H total solar radiation incident on collector N number of covers q u useful thermal energy collection rate per unit area q e useful electrical energy collection rate per unit area S absorbed solar radiation per unit area T a ambient temperature T c cover temperature T in inlet temperature T p mean plate temperature T r PV reference temperature T s sky temperature h f thermal conductance between absorber and fluid U BE bottom and edges heat loss coefficient U L overall heat loss coefficient U cpc convection heat loss coefficient among plate and cover U rcs radiation heat loss coefficient between cover and sky U rpc radiation heat loss coefficient between plate and cover U w convection heat loss coefficient due to wind speed ů mass flow rate V w wind velocity α effective absorptance of collector absorber 7

8 β r σ ε g ε p η r τ temperature coefficient of solar cell Stefan Boltzmann constant glass emissivity absorber plate emissivity cell efficiency at reference temperature transmittance of collector glass cover (16) IPART, Residential energy and water use in Sydney, the Blue Mountains and Illawarra Results from the 06 household survey, Independent Pricing and Regulatory Tribunal of New South Wales, REFERENCES (1) Florschuetz, L. W., Extension of the Hottel-Whillier model to the analysis of combined photovoltaic/thermal flat plate collectors, Solar Energy 22(4): 361-6, 1979 (2) Hottel, H. C., Whillier, W., Evaluation of flat-plate solar collector performance, Proceedings Of the Conference on the use of Solar Energy, University of Arizona, Vol II: , 1958 (3) Klein, S.A., Calculation of flat-plate collector loss coefficients, Solar Energy 17: 79-80, 1975 (4) McAdams, W.C., Heat Transmission (3 rd Edn), McGraw-Hill, 1954 (5) Duffie, J.A. and Beckman W.A., Solar Engineering of Thermal Processes (3 rd Edn), Wiley, 06 (6) Charalambous, et al., Photovoltaic thermal (PV/T) collectors: A review, Applied Thermal Engineering 27(2-3): , 07 (7) Zondag, H. A., Flat-plate PV-Thermal collectors and systems: A review, Renewable and Sustainable Energy Reviews 12(4): , 08 (8) Bergene, T. and O. M. Løvvik., Model calculations on a flat-plate solar heat collector with integrated solar cells, Solar Energy 55(6): , 1995 (9) Sandnes, B. and J. Rekstad., A photovoltaic/thermal (PV/T) collector with a polymer absorber plate. Experimental study and analytical model, Solar Energy 72(1): 63-73, 02 (10) Zondag, H. A., de Vries, D. W., et al., The thermal and electrical yield of a PV-thermal collector, Solar Energy 72(2): , 02 (11) Akhtar, N. and Mullick, S. C., Approximate Method For Computation of Glass Cover Temperature and Top Heat-Loss Coefficient of Solar Collectors with Single Glazing, Solar Energy 66(5): , 1999 (12) Buchberg, H., Catton, I., Edwards, D.K., Natural Convection in Enclosed Spaces - A Review of Application to Solar Energy Collection, Journal of Heat Transfer 98(2): , 1976 (13) Cooper, P.I., The Effect of Inclination on the Heat Loss From Flat-Plate Solar Collectors, Solar Energy 27(5):413-4, 1981 (14) PVT performance measurement guidelines, PV Catapult, ECN and ISFH, 05 (15) DEWHA, Energy Use in the Australian Residential Sector 1986, Department of the Environment, Water, Heritage and the Arts, 09 8

Simplified Collector Performance Model

Simplified Collector Performance Model Simplified Collector Performance Model Prediction of the thermal output of various solar collectors: The quantity of thermal energy produced by any solar collector can be described by the energy balance

More information

Performance Assessment of PV/T Air Collector by Using CFD

Performance Assessment of PV/T Air Collector by Using CFD Performance Assessment of /T Air Collector by Using CFD Wang, Z. Department of Built Environment, University of Nottingham (email: laxzw4@nottingham.ac.uk) Abstract Photovoltaic-thermal (/T) collector,

More information

Thermal Analysis of a Flat-Plate Solar Collectors in Parallel and Series Connections Huseyin Gunerhan

Thermal Analysis of a Flat-Plate Solar Collectors in Parallel and Series Connections Huseyin Gunerhan Thermal Analysis of a Flat-Plate Solar Collectors in Parallel and Series Connections Huseyin Gunerhan Department of Mechanical Engineering, Faculty of Engineering Ege University, 35100 Bornova, Izmir,

More information

Optimization of the Air Gap Spacing In a Solar Water Heater with Double Glass Cover

Optimization of the Air Gap Spacing In a Solar Water Heater with Double Glass Cover Optimization of the Air Gap Spacing In a Solar Water Heater with Double Glass Cover ABSTRACT M. AL-Khaffajy 1 and R. Mossad 2 Faculty of Engineering and Surveying, University of Southern Queensland, QLD

More information

Performance of contact and non-contact type hybrid photovoltaic-thermal (PV-T) collectors

Performance of contact and non-contact type hybrid photovoltaic-thermal (PV-T) collectors Performance of contact and non-contact type hybrid photovoltaic-thermal (PV-T) collectors S. Khandelwal, K. S. Reddy and S. Srinivasa Murthy (corresponding author) Department of Mechanical Engineering

More information

Natural convective heat transfer in trapezoidal enclosure of box-type solar cooker

Natural convective heat transfer in trapezoidal enclosure of box-type solar cooker Natural convective heat transfer in trapezoidal enclosure of box-type solar cooker Subodh Kumar * Centre for Energy Studies, Indian Institute of Technology, Hauz Khas, New Delhi 110016, India Received

More information

EFFECT OF OPERATING PARAMETERS ON THE PERFORMANCE OF THE HYBRID SOLAR PVT COLLECTOR UNDER DIFFERENT WEATHER CONDITION

EFFECT OF OPERATING PARAMETERS ON THE PERFORMANCE OF THE HYBRID SOLAR PVT COLLECTOR UNDER DIFFERENT WEATHER CONDITION International Journal of Science, Environment and Technology, Vol. 3, No 4, 2014, 1563 1570 ISSN 2278-3687 (O) EFFECT OF OPERATING PARAMETERS ON THE PERFORMANCE OF THE HYBRID SOLAR PVT COLLECTOR UNDER

More information

Construction and performance analysis of a three dimensional compound parabolic concentrator for a spherical absorber

Construction and performance analysis of a three dimensional compound parabolic concentrator for a spherical absorber 558 Journal of Scientific & Industrial Research J SCI IND RES VOL 66 JULY 2007 Vol. 66, July 2007, pp. 558-564 Construction and performance analysis of a three dimensional compound parabolic concentrator

More information

Theoretical Analysis of Overall Heat Loss Coefficient in a Flat Plate Solar Collector with an In-Built Energy Storage Using a Phase Change Material

Theoretical Analysis of Overall Heat Loss Coefficient in a Flat Plate Solar Collector with an In-Built Energy Storage Using a Phase Change Material Theoretical Analysis of Overall Heat Loss Coefficient in a Flat Plate Solar Collector with an In-Built Energy Storage Using a Phase Change Material R. Sivakumar and V. Sivaramakrishnan Abstract Flat Plate

More information

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY [Rabadiya, 1(7): Sep., 2012] ISSN: 2277-9655 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Effect of Wind Velocity At different Yaw Angle On Top Loss Coefficient Of Solar Flat

More information

DETAILED MODELING OF SOLAR FLAT-PLATE COLLECTORS WITH DESIGN TOOL KOLEKTOR 2.2

DETAILED MODELING OF SOLAR FLAT-PLATE COLLECTORS WITH DESIGN TOOL KOLEKTOR 2.2 1 2 3 4 5 6 7 8 9 10 DETAILED MODELING OF SOLAR FLAT-PLATE COLLECTORS WITH DESIGN TOOL KOLEKTOR 2.2 ABSTRACT Tomas Matuska, Vladimir Zmrhal, and Juliane Metzger Department of Environmental Engineering,

More information

CFD ANALYSIS OF HEAT TRANSFER AND FLUID FLOW IN FLAT PLATE NATURAL CONVECTION SOLAR AIR HEATER

CFD ANALYSIS OF HEAT TRANSFER AND FLUID FLOW IN FLAT PLATE NATURAL CONVECTION SOLAR AIR HEATER CFD ANALYSIS OF HEAT TRANSFER AND FLUID FLOW IN FLAT PLATE NATURAL CONVECTION SOLAR AIR HEATER Demiss Alemu Amibe, Alemu Tiruneh Department of Mechanical Engineering Addis Ababa Institute of Technology,

More information

UNIT FOUR SOLAR COLLECTORS

UNIT FOUR SOLAR COLLECTORS ME 476 Solar Energy UNIT FOUR SOLAR COLLECTORS Flat Plate Collectors Outline 2 What are flat plate collectors? Types of flat plate collectors Applications of flat plate collectors Materials of construction

More information

Modelling Results of Covered PVT Collectors regarding Low-E Coatings and F

Modelling Results of Covered PVT Collectors regarding Low-E Coatings and F Aix-les-Bains (France), 16-19 September 214 Modelling Results of Covered PVT Collectors regarding Low-E Coatings and F Manuel Lämmle, Thomas Kroyer, Stefan Fortuin and Michael Hermann Fraunhofer Institute

More information

Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR. 5.1 Thermal Model of Solar Collector System

Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR. 5.1 Thermal Model of Solar Collector System Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR This chapter deals with analytical method of finding out the collector outlet working fluid temperature. A dynamic model of the solar collector

More information

not for commercial-scale installations. Thus, there is a need to study the effects of snow on

not for commercial-scale installations. Thus, there is a need to study the effects of snow on 1. Problem Statement There is a great deal of uncertainty regarding the effects of snow depth on energy production from large-scale photovoltaic (PV) solar installations. The solar energy industry claims

More information

NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS

NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS THERMAL SCIENCE, Year 2011, Vol. 15, No. 2, pp. 457-465 457 NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS by Vukman V. BAKI] *, Goran S. @IVKOVI], and Milada L. PEZO Laboratory

More information

Comparison of PV Cell Temperature Estimation by Different Thermal Power Exchange Calculation Methods

Comparison of PV Cell Temperature Estimation by Different Thermal Power Exchange Calculation Methods European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ International Conference on Renewable Energies and Power Quality (ICREPQ 1 Santiago de Compostela (Spain,

More information

Parametric Effect on Performance Enhancement of Offset Finned Absorber Solar Air Heater

Parametric Effect on Performance Enhancement of Offset Finned Absorber Solar Air Heater Parametric Effect on Performance Enhancement of Offset Finned Absorber Solar Air Heater Er. Vivek Garg Gateway Institute of Engineering and Technology, Sonipat Mechanical Engineering Department Dr. Shalini

More information

OPTIMIZATION of the GEOMETRY & MATERIAL of SOLAR WATER HEATERS.

OPTIMIZATION of the GEOMETRY & MATERIAL of SOLAR WATER HEATERS. OPTIMIZATION of the GEOMETRY & MATERIAL of SOLAR WATER HEATERS. FLAT PLATE COLLECTORS ABSORBER PLATES OPTIMIZATION OF GEOMETRY SELECTIVE SURFACES METHODS OF TESTING TO DETERMINE THE THERMAL PERFORMANCE

More information

ADVANCED ROOF COATINGS: MATERIALS AND THEIR APPLICATIONS

ADVANCED ROOF COATINGS: MATERIALS AND THEIR APPLICATIONS ADVANCED ROOF COATINGS: MATERIALS AND THEIR APPLICATIONS Abstract J.M. Bell 1 and G.B. Smith 2 The use of low emittance and high solar reflectance coatings is widespread in window glazings, wall and roof

More information

Vertical Mantle Heat Exchangers for Solar Water Heaters

Vertical Mantle Heat Exchangers for Solar Water Heaters for Solar Water Heaters Y.C., G.L. Morrison and M. Behnia School of Mechanical and Manufacturing Engineering The University of New South Wales Sydney 2052 AUSTRALIA E-mail: yens@student.unsw.edu.au Abstract

More information

ME 476 Solar Energy UNIT TWO THERMAL RADIATION

ME 476 Solar Energy UNIT TWO THERMAL RADIATION ME 476 Solar Energy UNIT TWO THERMAL RADIATION Unit Outline 2 Electromagnetic radiation Thermal radiation Blackbody radiation Radiation emitted from a real surface Irradiance Kirchhoff s Law Diffuse and

More information

Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures

Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures Peer Reviewed Paper Piratheepan Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures Abstract M Piratheepan 1, T N Anderson 1, S Saiful 1 1 Auckland University of

More information

HEAT LOSS CHARACTERISTICS OF A ROOF INTEGRATED SOLAR MICRO-CONCENTRATING COLLECTOR

HEAT LOSS CHARACTERISTICS OF A ROOF INTEGRATED SOLAR MICRO-CONCENTRATING COLLECTOR 5 th International Conference on Energy Sustainability ASME August 7-10, 2011, Grand Hyatt Washington, Washington DC, USA ESFuelCell2011-54254 HEAT LOSS CHARACTERISTICS OF A ROOF INTEGRATED SOLAR MICRO-CONCENTRATING

More information

Improved energy management method for auxiliary electrical energy saving in a passive-solar-heated residence

Improved energy management method for auxiliary electrical energy saving in a passive-solar-heated residence Energy and Buildings 34 (2002) 699 703 Improved energy management method for auxiliary electrical energy saving in a passive-solar-heated residence G.C. Bakos Department of Electrical Engineering and Electronics,

More information

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: , ICAER 2011 AN EXPERIMENTAL AND COMPUTATIONAL INVESTIGATION OF HEAT LOSSES FROM THE CAVITY RECEIVER USED IN LINEAR FRESNEL REFLECTOR SOLAR THERMAL SYSTEM Sudhansu S. Sahoo* a, Shinu M. Varghese b, Ashwin

More information

Solar Flat Plate Thermal Collector

Solar Flat Plate Thermal Collector Solar Flat Plate Thermal Collector INTRODUCTION: Solar heater is one of the simplest and basic technologies in the solar energy field. Collector is the heart of any solar heating system. It absorbs and

More information

EFFECT OF INTERNAL LONG WAVE RADIATION AND CONVECTION ON FENESTRATION SIMULATION

EFFECT OF INTERNAL LONG WAVE RADIATION AND CONVECTION ON FENESTRATION SIMULATION EFFECT OF INTERNAL LONG WAVE RADIATION AND CONVECTION ON FENESTRATION SIMULATION Adelqui Fissore Sch. University of Concepción Mechanical Engineering Department Concepción - Chile ABSTRACT This paper presents

More information

Experimental Investigation of the Effect of Forced Convection on Solar Thermal Collector Efficiency

Experimental Investigation of the Effect of Forced Convection on Solar Thermal Collector Efficiency Research article Experimental Investigation of the Effect of Forced Convection on Solar Thermal Collector Efficiency Kevin R. Anderson, Raymond Faull, Charles Lowry, Thomas Tran California State Polytechnic

More information

HEAT TRANSFER ENHANCEMENT OF SOLAR FLAT PLATE COLLECTOR BY USING V CORRUGATED FINS AND VARIOUS PARAMETERS

HEAT TRANSFER ENHANCEMENT OF SOLAR FLAT PLATE COLLECTOR BY USING V CORRUGATED FINS AND VARIOUS PARAMETERS HEAT TRANSFER ENHANCEMENT OF SOLAR FLAT PLATE COLLECTOR BY USING V CORRUGATED FINS AND VARIOUS PARAMETERS Manoj S. Chaudhari 1, Mahesh Jagadale 2 1,2 Department of Mechanical Engineering, SPP University,

More information

Numerical Analysis of Heat Transfer Performance of Flat Plate Solar Collectors

Numerical Analysis of Heat Transfer Performance of Flat Plate Solar Collectors Avestia Publishing Journal of Fluid Flow, Heat and Mass Transfer Volume 1, Year 2014 ISSN: 2368-6111 DOI: 10.11159/jffhmt.2014.006 Numerical Analysis of Heat Transfer Performance of Flat Plate Solar Collectors

More information

Design strategy for Low e windows with effective insulation

Design strategy for Low e windows with effective insulation Design strategy for Low e windows with effective insulation Michael P.C. Watts, Impattern Solutions, www.impattern.com Keywords; insulating windows. low emission glass, ABSTRACT Optimal window glass assemblies

More information

Development and Validation of Flat-Plate Collector Testing Procedures

Development and Validation of Flat-Plate Collector Testing Procedures Development and Validation of Flat-Plate Collector Testing Procedures Report for March, 2007 Focus on Energy (FOE) supports solar thermal systems that displace conventional fuels by offering cash-back

More information

A parametric study on the thermal performance of cross-corrugated solar air collectors

A parametric study on the thermal performance of cross-corrugated solar air collectors Applied hermal Engineering 26 (26) 143 153 www.elsevier.com/locate/thermeng A parametric study on the thermal performance of cross-corrugated solar air collectors Wenxian Lin a,b, *, Wenfeng Gao a, ao

More information

Heat Transfer Enhancement of Solar Flat Plate Collector by Using V Corrugated Fins and Various Parameters

Heat Transfer Enhancement of Solar Flat Plate Collector by Using V Corrugated Fins and Various Parameters International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Heat

More information

Research Article Study on Effect of Number of Transparent Covers and Refractive Index on Performance of Solar Water Heater

Research Article Study on Effect of Number of Transparent Covers and Refractive Index on Performance of Solar Water Heater Renewable Energy Volume 14, Article ID 757618, 11 pages http://dx.doi.org/1.1155/14/757618 Research Article Study on Effect of Number of Transparent Covers and Refractive Index on Performance of Solar

More information

A dynamic model of hybrid photovoltaic/thermal panel

A dynamic model of hybrid photovoltaic/thermal panel November 5-7, 2009 - Sousse Tunisia A dynamic model of hybrid photovoltaic/thermal panel Majed Ben Ammar, Mohsen Ben Ammar,2 and Maher Chaabene Unité de Commande de Machines et Réseaux de Puissance (CMERP,

More information

SIMULATION OF FRAME CAVITY HEAT TRANSFER USING BISCO v10w

SIMULATION OF FRAME CAVITY HEAT TRANSFER USING BISCO v10w PHYSIBEL SIMULATION OF FRAME CAVITY HEAT TRANSFER USING BISCO v10w Introduction In construction elements such as window frames and bricks, the heat transfer through air cavities is often a quite important

More information

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 ISSN 0976 6340 (Print) ISSN 0976 6359 (Online) Volume

More information

THERMAL DYNAMIC BEHAVIOR OF SINGLE COMPONENT: EXPERIMENTAL ANALYSIS AND NUMERICAL MODELING

THERMAL DYNAMIC BEHAVIOR OF SINGLE COMPONENT: EXPERIMENTAL ANALYSIS AND NUMERICAL MODELING U.P.B. Sci. Bull., Series C, Vol. 74, Iss. 1, 2012 ISSN 1454-234x THERMAL DYNAMIC BEHAVIOR OF SINGLE COMPONENT: EXPERIMENTAL ANALYSIS AND NUMERICAL MODELING Paolo BAGGIO 1, Alessandro PRADA 2 In the present

More information

Simulation Application for Optimization of Solar Collector Array

Simulation Application for Optimization of Solar Collector Array RESEARCH ARTICLE OPEN ACCESS Simulation Application for Optimization of Solar Collector Array Igor Shesho*, Done Tashevski** *(Department of Thermal Engineering, Faculty of Mechanical Engineering, "Ss.

More information

Liquid-Air Transpired Solar Collector: Model Development and Sensitivity Analysis

Liquid-Air Transpired Solar Collector: Model Development and Sensitivity Analysis 2 JAN 24 Liquid-Air Transpired Solar Collector: Model Development and Sensitivity Analysis Abdul Qadir Graduate Student, Masdar Institute of Science and Technology Abu Dhabi, United Arab Emirates Peter

More information

THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE

THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE Thamer Khalif Salem Mechanical Engineering, College of Engineering, Tikrit University, IRAQ. thamer_khalif@yahoo.com

More information

THE SIMPLIFIED CALCULUS OF THE FLAT PLATE SOLAR COLLECTOR

THE SIMPLIFIED CALCULUS OF THE FLAT PLATE SOLAR COLLECTOR Annals of the University of Craiova, lectrical ngineering series, No. 30, 006 TH SIMPLIFID CALCULUS OF TH FLAT PLAT SOLAR COLLCTOR Andrei Ştefan JRCAN Student - University of Craiova, Faculty of lectric

More information

Analysis of a Plate Heat Pipe Solar Collector

Analysis of a Plate Heat Pipe Solar Collector SET 2004 - International Conference on Sustainable Energy Technologies Nottingham, UK, 28-30 June 2004 Page 1 of 5 Analysis of a Plate Heat Pipe Solar Collector Jorge Facão and Armando C Oliveira Faculty

More information

Deposited on: 01 September 2011

Deposited on: 01 September 2011 Wilson, M.J. and Paul, M.C. (2011) Effect of mounting geometry on convection occurring under a photovoltaic panel and the corresponding efficiency using CFD. Solar Energy, 85 (10). pp. 2540-2550. ISSN

More information

Enerpool v Swimming Pool Simulation Simulation File: C:\ENERPOOL\SANDA.EPL Run on: Fri Feb 07 19:27:

Enerpool v Swimming Pool Simulation Simulation File: C:\ENERPOOL\SANDA.EPL Run on: Fri Feb 07 19:27: Enerpool v. 2.1.6 - Swimming Pool Simulation Simulation File: C:\ENERPOOL\SANDA.EPL Run on: Fri Feb 07 19:27:43 2003 POOL CONFIGURATION: - Solar Collector - No Heat Exchanger - Auxiliary Heater - Weather

More information

PLEASE SCROLL DOWN FOR ARTICLE

PLEASE SCROLL DOWN FOR ARTICLE This article was downloaded by:[james Cook University] On: 14 November 2007 Access Details: [subscription number 780011387] Publisher: Taylor & Francis Informa Ltd Registered in England and Wales Registered

More information

StudyOn The Thermal Performance Of Flat Plate Solar Air Collectors With Dust Deposition On The Transparent Covers

StudyOn The Thermal Performance Of Flat Plate Solar Air Collectors With Dust Deposition On The Transparent Covers StudyOn The Thermal Performance Of Flat Plate Solar Air Collectors With Dust Deposition On The Transparent Covers J.Deng 1,M.Yang 2,X.D.Yang 1,*,P.S.Wang 1 1 Department of Building Science, Tsinghua University,

More information

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 6, Issue 11, May 2017

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 6, Issue 11, May 2017 Experimental Investigation and Fabrication of Serpentine Flat-Plate Collector to predict the Performance Srinivas Prasad Sanaka 1, P.K.Bharadwaj 2, BLVS Gupta 3 1 Professor, 2 Student, 3 Assistant Professor

More information

Development and Validation of Flat-Plate Collector Testing Procedures

Development and Validation of Flat-Plate Collector Testing Procedures Development and Validation of Flat-Plate Collector Testing Procedures Report for February, 2007 Focus on Energy (FOE) supports solar thermal systems that displace conventional fuels by offering cash-back

More information

Basic information about developed Calculator for solar / wind hybrid power supply

Basic information about developed Calculator for solar / wind hybrid power supply Basic information about developed Calculator for solar / wind hybrid power supply It simulates behavior of the system for off grid power supply (components: solar panels, wind generator, batteries and

More information

Analysis of the thermal heating of poly-si and a-si photovoltaic cell by means of Fem

Analysis of the thermal heating of poly-si and a-si photovoltaic cell by means of Fem European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ) International Conference on Renewable Energies and Power Quality (ICREPQ 10) Granada (Spain), 23th

More information

Applied Energy 84 (2007) Analytical and experimental studies on the thermal performance of cross-corrugated and flat-plate solar air heaters

Applied Energy 84 (2007) Analytical and experimental studies on the thermal performance of cross-corrugated and flat-plate solar air heaters Applied Energy 84 (2007) 425 44 APPLED ENERGY www.elsevier.com/locate/apenergy Analytical and experimental studies on the thermal performance of cross-corrugated and flat-plate solar air heaters Wenfeng

More information

THERMAL PERFORMANCE OPTIMIZATION OF A FLAT PLATE SOLAR WATER HEATER COLLECTOR USING MATLAB

THERMAL PERFORMANCE OPTIMIZATION OF A FLAT PLATE SOLAR WATER HEATER COLLECTOR USING MATLAB THERMAL PERFORMANCE OPTIMIZATION OF A FLAT PLATE SOLAR WATER HEATER COLLECTOR USING MATLAB 1 H.VETTRIVEL, 2 P.MATHIAZHAGAN 1,2 Assistant professor, Mechanical department, Manalula Vinayakar institute of

More information

A Typical Meteorological Year for Energy Simulations in Hamilton, New Zealand

A Typical Meteorological Year for Energy Simulations in Hamilton, New Zealand Anderson T N, Duke M & Carson J K 26, A Typical Meteorological Year for Energy Simulations in Hamilton, New Zealand IPENZ engineering trenz 27-3 A Typical Meteorological Year for Energy Simulations in

More information

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS Mark Luther 1, Timothy Anderson 2, and Tim Brain 3 1 School of Architecture and Building, Deakin University, Geelong, Australia 2 School

More information

Thermal resistance model for CSP central receivers

Thermal resistance model for CSP central receivers Thermal resistance model for CSP central receivers O. A. J. de Meyer, F. Dinter, and S. Govender Citation: AIP Conference Proceedings 1734, 030010 (2016); doi: 10.1063/1.4949062 View online: http://dx.doi.org/10.1063/1.4949062

More information

Chapter 2 Available Solar Radiation

Chapter 2 Available Solar Radiation Chapter 2 Available Solar Radiation DEFINITIONS Figure shows the primary radiation fluxes on a surface at or near the ground that are important in connection with solar thermal processes. DEFINITIONS It

More information

Reading Problems , 15-33, 15-49, 15-50, 15-77, 15-79, 15-86, ,

Reading Problems , 15-33, 15-49, 15-50, 15-77, 15-79, 15-86, , Radiation Heat Transfer Reading Problems 15-1 15-7 15-27, 15-33, 15-49, 15-50, 15-77, 15-79, 15-86, 15-106, 15-107 Introduction The following figure shows the relatively narrow band occupied by thermal

More information

Dynamic thermal simulation of a solar chimney with PV modules

Dynamic thermal simulation of a solar chimney with PV modules International Conerence Passive and Low Energy Cooling 89 Dynamic thermal simulation o a solar chimney with PV modules J. Martí-Herrero and M.R. Heras-Celemin Energetic Eiciency in Building, CIEMAT, Madrid,

More information

International Journal of Advanced Engineering Technology E-ISSN

International Journal of Advanced Engineering Technology E-ISSN Research Article EFFECT OF ROUGHNESS ELEMENT PITCH ON HEAT TRANSFER AND FRICTION CHARACTERISTICS OF ARTIFICIALLY ROUGHENED SOLAR AIR HEATER DUCT Aman Soi*, Ranjit Singh, Brij Bhushan Address for Correspondence

More information

Determination of Optimum Fixed and Adjustable Tilt Angles for Solar Collectors by Using Typical Meteorological Year data for Turkey

Determination of Optimum Fixed and Adjustable Tilt Angles for Solar Collectors by Using Typical Meteorological Year data for Turkey Determination of Optimum Fixed and Adjustable Tilt Angles for Solar Collectors by Using Typical Meteorological Year data for Turkey Yohannes Berhane Gebremedhen* *Department of Agricultural Machinery Ankara

More information

Solar Radiation and Solar Programs. Training Consulting Engineering Publications GSES P/L

Solar Radiation and Solar Programs. Training Consulting Engineering Publications GSES P/L Solar Radiation and Solar Programs Training Consulting Engineering Publications SOLAR RADIATION Purposes of Solar Radiation Software Successful project planning and solar plant implementation starts by

More information

Effects of Nanofluids Thermo-Physical Properties on the Heat Transfer and 1 st law of Thermodynamic in a Serpentine PVT System

Effects of Nanofluids Thermo-Physical Properties on the Heat Transfer and 1 st law of Thermodynamic in a Serpentine PVT System Effects of Nanofluids Thermo-Physical Properties on the Heat Transfer and 1 st law of Thermodynamic in a Serpentine PVT System Seyed Reza Maadi Ferdowsi University of Mashhad reza_maadi@mail.um.ac.ir Mohammad

More information

Thermal conversion of solar radiation. c =

Thermal conversion of solar radiation. c = Thermal conversion of solar radiation The conversion of solar radiation into thermal energy happens in nature by absorption in earth surface, planetary ocean and vegetation Solar collectors are utilized

More information

Simulation of a concentrating PV/thermal collector using TRNSYS

Simulation of a concentrating PV/thermal collector using TRNSYS Simulation o a concentrating PV/ermal lector using TRNSYS Abstract Centre or Sustainable Energy Systems Australian National University Canberra 0200 ACT AUSTRALIA Telephone: +61 02 6125 3976 Facsimile:

More information

Scholars Research Library

Scholars Research Library Available online at www.scholarsresearchlibrary.com Archives of Physics Research, 2013, 4 (2):4-13 (http://scholarsresearchlibrary.com/archive.html) ISSN : 0976-0970 CODEN (USA): APRRC7 Experimental investigations

More information

Durability Analysis on Solar Energy Converters containing Polymeric Materials

Durability Analysis on Solar Energy Converters containing Polymeric Materials Excerpt from the Proceedings of the COMSOL Conference 008 Hannover Durability Analysis on Solar Energy Converters containing Polymeric Materials Jochen Wirth*, Steffen Jack, Michael Köhl and Karl-Anders

More information

Paper No. : 04 Paper Title: Unit Operations in Food Processing Module-07: Heat Transfer 3: Heat Radiation

Paper No. : 04 Paper Title: Unit Operations in Food Processing Module-07: Heat Transfer 3: Heat Radiation Paper No. : 04 Paper Title: Unit Operations in Food Processing Module-07: Heat Transfer 3: Heat Radiation 7.1 Introduction Radiation heat transfer is the transfer of heat energy in the form of electromagnetic

More information

USEFUL WASTE HEAT OF VENTILATED PV-MODULES: PHYSICAL MODELLING AND VALIDATION RESULTS. Lucerne, Switzerland. to

USEFUL WASTE HEAT OF VENTILATED PV-MODULES: PHYSICAL MODELLING AND VALIDATION RESULTS. Lucerne, Switzerland.  to USEFUL WASTE HEAT OF VENTILATED PV-MODULES: PHYSICAL MODELLING AND VALIDATION RESULTS Sven Kropf 1, Alfred Moser 1, and Gerhard Zweifel 2 1 Institute for Building Technology, ETH, Zürich, Switzerland 2

More information

Heat Transfer: A Practical Approach - Yunus A Cengel Assignment 11 Fall 2003 Tuesday, November 18, 2003 Chapter 11, Problem 49

Heat Transfer: A Practical Approach - Yunus A Cengel Assignment 11 Fall 2003 Tuesday, November 18, 2003 Chapter 11, Problem 49 Heat Transer: A Practical Approach - Yunus A Cengel Assignment Fall 00 Tuesday, November 8, 00 Chapter, Problem 9 The variation o the spectral transmissivity o a 0.6- cm-thick glass window is as given

More information

Research Article Improving the Electrical Parameters of a Photovoltaic Panel by Means of an Induced or Forced Air Stream

Research Article Improving the Electrical Parameters of a Photovoltaic Panel by Means of an Induced or Forced Air Stream International Photoenergy Volume 2, Article ID 83968, 1 pages http://dx.doi.org/1.15/2/83968 Research Article Improving the Electrical Parameters of a Photovoltaic Panel by Means of an Induced or Forced

More information

Experimental study on heat losses from external type receiver of a solar parabolic dish collector

Experimental study on heat losses from external type receiver of a solar parabolic dish collector IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Experimental study on heat losses from external type receiver of a solar parabolic dish collector To cite this article: V Thirunavukkarasu

More information

The Electrodynamics of a Pair of PV Modules with Connected Building Resistance

The Electrodynamics of a Pair of PV Modules with Connected Building Resistance Proc. of the 3rd IASME/WSEAS Int. Conf. on Energy, Environment, Ecosystems and Sustainable Development, Agios Nikolaos, Greece, July 24-26, 2007 563 he Electrodynamics of a Pair of s with Connected Building

More information

Solar water heating. Chapter Introduction

Solar water heating. Chapter Introduction Chapter 5 Solar water heating 5.1 Introduction An obvious use of solar energy is for heating air and water. Dwellings in cold climates need heated air for comfort, and in all countries hot water is used

More information

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions Available online at www.sciencedirect.com Solar Energy 84 (2010) 1382 1396 www.elsevier.com/locate/solener Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors

More information

The influence of PV coverage ratio on thermal and electrical performance of photovoltaic-trombe wall

The influence of PV coverage ratio on thermal and electrical performance of photovoltaic-trombe wall Renewable Energy ] (]]]]) ]]] ]]] Technical Note The influence of PV coverage ratio on thermal and electrical performance of photovoltaic-trombe wall Bin Jiang a,, Jie Ji b, Hua Yi b a Faculty of Urban

More information

Heat Loss from Cavity Receiver for Solar Micro- Concentrating Collector

Heat Loss from Cavity Receiver for Solar Micro- Concentrating Collector Heat Loss from Cavity Receiver for Solar Micro- Concentrating Collector Tanzeen Sultana 1, Graham L Morrison 1, Andrew Tanner 2, Mikal Greaves 2, Peter Le Lievre 2 and Gary Rosengarten 1 1 School of Mechanical

More information

Performance Investigation of Cavity Absorber for Parabolic Dish Solar Concentrator

Performance Investigation of Cavity Absorber for Parabolic Dish Solar Concentrator Volume 117 No. 7 217, 345-358 ISSN: 1311-88 (printed version); ISSN: 1314-3395 (on-line version) url: http://www.ijpam.eu ijpam.eu Performance Investigation of Cavity Absorber for Parabolic Dish Solar

More information

ELEC9712 High Voltage Systems. 1.2 Heat transfer from electrical equipment

ELEC9712 High Voltage Systems. 1.2 Heat transfer from electrical equipment ELEC9712 High Voltage Systems 1.2 Heat transfer from electrical equipment The basic equation governing heat transfer in an item of electrical equipment is the following incremental balance equation, with

More information

Double-Skin Facade in Low-Latitude: Study on the Absorptance, Reflectance, and Transmittance of Direct Solar Radiation

Double-Skin Facade in Low-Latitude: Study on the Absorptance, Reflectance, and Transmittance of Direct Solar Radiation ouble-skin Facade in Low-Latitude: Study on the Absorptance, Reflectance, and Transmittance of irect Solar Radiation G-LO 011 Rosady Mulyadi epartment of Architecture Faculty of Engineering Hasanuddin

More information

The energy performance of an airflow window

The energy performance of an airflow window The energy performance of an airflow window B.(Bram) Kersten / id.nr. 0667606 University of Technology Eindhoven, department of Architecture Building and Planning, unit Building Physics and Systems. 10-08-2011

More information

Load Adapted Solar Thermal Combisystems Optical Analysis and Systems Optimization

Load Adapted Solar Thermal Combisystems Optical Analysis and Systems Optimization Load Adapted Solar Thermal Combisystems Optical Analysis and Systems Optimization LICENTIATE THESIS SVANTE NORDLANDER December 2004 Department of Engineering Sciences Uppsala University ISSN 0346-8887,

More information

Collector test according to EN ,2:2002

Collector test according to EN ,2:2002 Test Report: KTB Nr. 2003-18-b-en Collector test according to EN 12975-1,2:2002 for: RM Solar Ltd Brand Name: S-Class Responsible for Testing: Dipl.-Ing. (FH) A. Schäfer Date: 17th July 2006 Address: Fraunhofer-Institute

More information

Australian Solar Cooling Interest Group (ausscig) Conference 2013

Australian Solar Cooling Interest Group (ausscig) Conference 2013 Autralian Solar Cooling Interet Group (auscig) Conference 1 Timothy Anderon1,Mike Duke, and Jame Caron 1 School of Engineering, Auckland Univerity of Technology School of Engineering, Univerity of Waikato

More information

Small size single-axis PV trackers: control strategies and system layout for energy optimization

Small size single-axis PV trackers: control strategies and system layout for energy optimization Available online at www.sciencedirect.com ScienceDirect Energy Procedia 82 (2015 ) 737 743 ATI 2015-70th Conference of the ATI Engineering Association Small size single-axis PV trackers: control strategies

More information

Feasibility study of one axis three positions tracking solar PV with low concentration ratio reflector

Feasibility study of one axis three positions tracking solar PV with low concentration ratio reflector Energy Conversion and Management 48 (27) 1273 128 www.elsevier.com/locate/enconman Feasibility study of one axis three positions tracking solar PV with low concentration ratio reflector B.J. Huang *, F.S.

More information

Chapter 1 INTRODUCTION AND BASIC CONCEPTS

Chapter 1 INTRODUCTION AND BASIC CONCEPTS Heat and Mass Transfer: Fundamentals & Applications 5th Edition in SI Units Yunus A. Çengel, Afshin J. Ghajar McGraw-Hill, 2015 Chapter 1 INTRODUCTION AND BASIC CONCEPTS Mehmet Kanoglu University of Gaziantep

More information

Design and Heat Loss Calculations from Double Effect Type Solar Still Integrated with LFPC

Design and Heat Loss Calculations from Double Effect Type Solar Still Integrated with LFPC International Journal of Emerging Engineering Research and Technology Volume 2, Issue 6, September 2014, PP 108-116 ISSN 2349-4395 (Print) & ISSN 2349-4409 (Online) Design and Heat Loss Calculations from

More information

A CFD Analysis Of A Solar Air Heater Having Triangular Rib Roughness On The Absorber Plate

A CFD Analysis Of A Solar Air Heater Having Triangular Rib Roughness On The Absorber Plate International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol.5, No.2, pp 964-971, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in

More information

Winter Night. Thermos 6mm Outdoors # #

Winter Night. Thermos 6mm Outdoors # # February 26, 2016 By Gagnon, Stephan stephan@thermosrn.ca Thermos 3mm à 6mm vs Climaguard 80/70 Make-up Name Make-up Icon Transmittance Reflectance U-Value Visible (τ v %) (τ e %) Visible ρ v % out ρ v

More information

ISESCO Science and Technology Vision

ISESCO Science and Technology Vision ISESCO Science and Technology Vision Volume 6 - Number 10 - November 2010 (39-54) Abstract is important to state Itthat Jordan, with global radiation of 2080 kwh/m 2 and more than 300 sunny days a year,

More information

The Peak Flux Constraints on Bladed Receiver Performance in High- Temperature Molten Salt Concentrating Solar Power Systems

The Peak Flux Constraints on Bladed Receiver Performance in High- Temperature Molten Salt Concentrating Solar Power Systems The Peak Flux Constraints on Bladed Receiver Performance in High- Temperature Molten Salt Concentrating Solar Power Systems Ye Wang, John Pye Solar Thermal Group, Research School of Engineering, The Australian

More information

PERFORMANCE EVALUATION OF REFLECTIVE COATINGS ON ROOFTOP UNITS

PERFORMANCE EVALUATION OF REFLECTIVE COATINGS ON ROOFTOP UNITS PERFORMANCE EVALUATION OF REFLECTIVE COATINGS ON ROOFTOP UNITS Report on DRAFT Prepared for: California Energy Commission 1516 9th Street Sacramento, CA 95814 Prepared by: Design & Engineering Services

More information

Energy yield I Unit 10

Energy yield I Unit 10 Energy yield I Unit 10 Marcus Rennhofer marcus.rennhofer@ait.ac.at Content Energy Yield Environmental parameters Irradiance Annual energy yield Generator quality measures Losses of energy Modelling Types

More information

Research Article Design and Modelling of Water Chilling Production System by the Combined Effects of Evaporation and Night Sky Radiation

Research Article Design and Modelling of Water Chilling Production System by the Combined Effects of Evaporation and Night Sky Radiation Renewable Energy, Article ID 624502, 8 pages http://dx.doi.org/10.1155/2014/624502 Research Article Design and Modelling of Water Chilling Production System by the Combined Effects of Evaporation and Night

More information

COMBINATION OF TAGUCHI METHOD AND ARTIFICIAL INTELLIGENCE TECHNIQUES FOR THE OPTIMAL DESIGN OF FLAT-PLATE COLLECTORS

COMBINATION OF TAGUCHI METHOD AND ARTIFICIAL INTELLIGENCE TECHNIQUES FOR THE OPTIMAL DESIGN OF FLAT-PLATE COLLECTORS COMBINATION OF TAGUCHI METHOD AND ARTIFICIAL INTELLIGENCE TECHNIQUES FOR THE OPTIMAL DESIGN OF FLAT-PLATE COLLECTORS Soteris A. Kalogirou Cyprus University of Technology, P. O. Box 509, 60, Limassol, Cyprus

More information

CAE 331/513 Building Science Fall 2016

CAE 331/513 Building Science Fall 2016 CAE 331/513 Building Science Fall 2016 Week 3: September 8, 2016 Heat transfer in buildings: Finish radiation, then solar radiation and windows Advancing energy, environmental, and sustainability research

More information