IES INDOOR REPORT PHOTOMETRIC FILENAME : RDISE24-LED48FRDMV35.IES. DESCRIPTION INFORMATION (From Photometric File)
|
|
- Rolf Payne
- 6 years ago
- Views:
Transcription
1 DESCRIPTION INFORMATION (From Photometric File) IESNA:LM [TEST] LLIA [TESTLAB] LightLab International Allentown, LLC [MANUFAC] Mobern Lighting Co., 8200 Stayton Drive, Jessup, MD 20794, USA [LUMCAT] RDISE24-LED48FRDMV35 [LUMINAIRE] Catalog Number: RDISE24-LED48FRDMV35 [MORE] Recess mounted, white formed steel 2x4 housing, white enamel internal reflector [MORE] with frosted acrylic enclosure. 64 white LEDs, four Universal Lighting [MORE] Technologies Everline M10CC835D32N2S boards with 32 LEDs each. One Universal [MORE] Lighting Technologies Everline D10CC55UNVTZ-C LED driver set to 860mA. [MORE] 120.0Vac, 60.0Hz, 0.40A, 48.0W, 0.995PF, 7.55%THD(i) [OTHER] Absolute test - lamp lumens value set to -1 [MORE] NA conventions used for C0 plane alignment and C-plane rotation direction. [MORE] The sample was tested at a distance of 9.5m. [MORE] This IES file was extrapolated from RDISE24-LED32FRDMV30. [DATE] This file created: Wednesday, January 4, :38 PM [ISSUEDATE] Wednesday, January 4, :38 PM CHARACTERISTICS Lumens Per Lamp N.A. (absolute) Total Lamp Lumens N.A. (absolute) Luminaire Lumens 5859 Total Luminaire Efficiency N.A. Luminaire Efficacy Rating (LER) 122 Total Luminaire Watts 48 Ballast Factor 1.00 CIE Type Direct Spacing Criterion (0-180) 1.22 Spacing Criterion (90-270) 1.30 Spacing Criterion (Diagonal) 1.38 Basic Luminous Shape Rectangular Luminous Length (0-180) 1.19 m Luminous Width (90-270) 0.58 m Luminous Height 0.00 m Page 1
2 LUMINANCE DATA (cd/sq.m) Angle In Average Average Average Degrees 0-Deg 45-Deg 90-Deg Page 2
3 CANDELA TABULATION Page 3
4 CANDELA TABULATION - (Cont.) Page 4
5 CANDELA TABULATION - (Cont.) Page 5
6 CANDELA TABULATION - (Cont.) Page 6
7 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A N.A Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone Lumens Page 7
8 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC RW Page 8
9 POLAR GRAPH Maximum Candela = Located At Horizontal Angle = 45, Vertical Angle =.5 # 1 - Vertical Plane Through Horizontal Angles (45-225) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (.5) (Through Max. Cd.) Page 9
IES INDOOR REPORT PHOTOMETRIC FILENAME : PFXC-CW-0-277E5-35WH-1.IES. DESCRIPTION INFORMATION (From Photometric File)
DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] 3610-2.0 [ECN] 3658 [TESTLAB] Tempo LLC [ISSUEDATE] 10/29/2018 9:53:53 AM [MANUFAC] Tempo LLC [LUMCAT] pfxc-cw-0-277e5-35wh-1 [LUMINAIRE]
More informationIES INDOOR REPORT PHOTOMETRIC FILENAME : C6R-LL-00-UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File)
DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] 1008 [UL TEST] 11750395.01 [ECN] 3056 [TESTLAB] UL Verification Services Inc. [ISSUEDATE] 5/4/2017 [MANUFAC] Tempo LLC [LUMCAT] C6R-LL-00-UNVE5-35-LG
More informationIES INDOOR REPORT PHOTOMETRIC FILENAME : SSLED4830-XX.IES. DESCRIPTION INFORMATION (From Photometric File)
DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] 11890707.03 [TESTLAB] UL Verification Services Inc. [ISSUEDATE] 8/15/2017 [MANUFAC] Lamar Lighting Co Inc [LUMCAT] SSLED4830-XX [LUMINAIRE]
More informationAdaptive architectural lighting systems IES Report
Adaptive architectural lighting systems IES Report BoxRail 107 107-BX-X-4-48-X-X-X-X-X-X-Z-HO-35-S2-X-BL-X The performance data in black text is confirmed through third party testing (see the following
More informationLED Flat Panel 1X4. Solas Ray Lighting 1524 Jackson Street Anderson, Indiana
LED Flat Panel 1X4 Photometric Filename: FP14-036-40-AC-U-D.IES Photometric Filename: FP14-036-40-AC-U-D.IES Descriptive Information (From Photometric File) IESNA:LM-63-2002 [TEST] 1 [TESTLAB] EVERFINE
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MANUFACTURE NAME 8165 E. KAISER BLVD, ANAHEIM, CA 92808
Test #: S01130101 Date: 1/1/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: S01130101 LUMINAIRE CATALOG NUMBER Report Prepared
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L04144701 Date: 4/21/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L04144701 WPW-1C-120 Report Prepared For: EiKO
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L06124406 Date: 7/11/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L06124406 MLFP22E4535 Report Prepared For: MAXLITE
More informationCalibration Due Date Chroma Programmable AC Source 61604
Test #: L09123902 Date: 9/18/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L09123902 ECO5-JP-3-35F Report Prepared For: BARTCO
More informationNumber Eight Lighting Company. 804/J2-WD-25/DIM WD with FS-P-1-WH trim
Report No: L121706467 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706467 Issue Date: 1/16/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L07121001 Date: 7/6/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L07121001 EDR-36NB-80-T5R-UNV-XXX-XX Report Prepared
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.
Report No: L031603401 Date: 3/15/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L0031603401 Report Prepared For: Osram Sylvania, Inc. Model
More informationNumber Eight Lighting Company MPT2-HI-R-6-BK/40/DIM1-M-1000
Report No: L121706547 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706547 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More informationNumber Eight Lighting Company MPT2-HI-R-6-BK/25/DIM1-M-1400
Report No: L121706549 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706549 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L011501402 Date: 1/14/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L011501402 Report Prepared For: Primus Lighting Inc. 3570
More informationMaxlite Jersey Blvd Rancho Cucamonga, CA Electrical and Photometric tests as required by the IESNA test standards.
Test #: L02144405 Date: 2/21/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L02144405 LSU2406U2050 / DV50 Report Prepared
More informationIES ROAD REPORT PHOTOMETRIC FILENAME : L IES. DESCRIPTIVE INFORMATION (From Photometric File)
DESCRIPTIVE INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L061805905 [TESTLAB] LIGHT LABORATORY, INC. (www.lightlaboratory.com) [ISSUEDATE] 7/6/2018 [MANUFAC] USTE, dba Vista Professional
More informationIES ROAD REPORT PHOTOMETRIC FILENAME : L IES. DESCRIPTIVE INFORMATION (From Photometric File)
DESCRIPTIVE INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L061805903 [TESTLAB] LIGHT LABORATORY, INC. (www.lightlaboratory.com) [ISSUEDATE] 7/5/2018 [MANUFAC] USTE, dba Vista Professional
More informationMaximum Candela from 80 to <90 Degrees Vertical (63.9% Luminaire Lumens) Cutoff Classification (deprecated)
DESCRIPTIVE INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L061805901 [TESTLAB] LIGHT LABORATORY, INC. (www.lightlaboratory.com) [ISSUEDATE] 7/5/2018 [MANUFAC] USTE, dba Vista Professional
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L041608003 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608003 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L041608103 Date: 4/28/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608103 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationGM LIGHTING 9830 W 190th St, Torrance, CA 90503
Report No: L041609202 Date: 5/3/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041609202 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationSuxess Inc., dba LUX Dynamics LED-LHB-2-UNV HO LADC
Report No: L031601802R02 Date: 5/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L031601802R02 Suxess Inc.,
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L091503801 Date: 9/16/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091503801 Report Prepared For: LEDCONN 301 Thor Place Model
More informationIES ROAD REPORT PHOTOMETRIC FILENAME : KU899-9LED.IES. DESCRIPTIVE INFORMATION (From Photometric File)
DESCRIPTIVE INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L02143701 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 02/20/2014 [MANUFAC] TMS LIGHTING [LUMINAIRE] KURAC LED SCONCE [LUMCAT] KU899-9LED
More informationIES ROAD REPORT PHOTOMETRIC FILENAME : LB-AL IES. DESCRIPTIVE INFORMATION (From Photometric File)
DESCRIPTIVE INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] [TESTLAB] Standard-Tech Co. Ltd [TESTDATE] 2015-06-23 [ISSUEDATE] 2015-06-23 21:57:22 [NEARFIELD] [LAMPPOSITION] 0,0 [OTHER] EVERFINE
More informationReport of Test LLIA A
Report of Test LLIA000795-001A Catalog Number: GTSOL112-G2-HO-BR-NL Two Mean Well HLG-240H-C2100B LED drivers 120.0Vac, 60.00Hz, 2.811A, 335.1W, 0.994PF, 5.5%THD(i) Total Light Output Luminaire Power Luminous
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE SPJ Lighting 2107 Chino Ave. South El Monte, CA.
Report No: L051503301 Date: 5/21/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051503301 Report Prepared For: SPJ Lighting 2107 Chino Ave.
More informationReport of Test LLIA
Report of Test LLIA55- Catalog Number: X One eldoled SOLOdriver 56/S, 5mA/May x25, LED driver 2.Vac, 6.Hz,.837A, 2.98W,.952PF, 5.44%THD(i) Total Light Output Luminaire Power Luminous Efficacy Performance
More informationBeachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI
Report No: L061507804R01 Date: 3/27/2018 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061507804R01 Report Prepared For: Beachside Lighting 905
More informationBeachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI
Report No: L061507814 Date: 7/24/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061507814 Report Prepared For: Beachside Lighting 905 Kalanianaole
More informationReport of Test LLIA A
Report of Test LLIA000998-002A Catalog Number: ML5WL-D-HO-ASY-K40-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 720mA. Total Light Output Luminaire Power Luminous Efficacy
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320
Report No: L051602710 Date: 5/24/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L051602710 HK Lighting Group
More informationReport of Test LLIA
Report of Test LLIA000792-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 9457 lm 78.6 W 120.3 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL 34135,
More informationReport of Test LLIA A
Report of Test LLIA000998-001A Catalog Number: ML3WL-D-HO-ASY-K35-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 600mA. Total Light Output Luminaire Power Luminous Efficacy
More informationReport of Test LLIA
Report of Test LLIA000792-003 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 8616 lm 70.3 W 122.6 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL 34135,
More informationReport of Test LLIA
Report of Test LLIA000795-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 35087 lm 296.1 W 118.5 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL
More informationLightLab I N T E R N A T I O N A L
Report of Test LLI-14188-20D Performance Summary Total Light Output 310 lm Min Power Factor 0.46 @ 277 V Luminaire Power 9.79 W Max THD(i)* 30.4 % @ 277 V Luminous Efficacy 31.7 lm/w SC along*, across*
More informationReport of Test LLIA
eport of Test LLIA000858-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 14313 lm 107.5 W 133.1 lm/w PEPAED FO : Topaz Lighting Corp, 925 Waverly Avenue, Holtsville, NY 11742,
More informationReport of Test LLIA
eport of Test LLIA001007-002 Catalog Number: F-AL/150/50K/S3 Total Light Output Luminaire Power Luminous Efficacy BUG ating 18778 lm 145.4 W 129.1 lm/w B3-U2-G3 Performance Summary Power Factor THD(i)
More informationReport of Test LLIA R02*
eport of Test LLIA001007-001-02* *This test report supersedes test report LLIA001007-001-01 Catalog Number: F-AL/0/50K/S3 Total Light Output Luminaire Power Luminous Efficacy BUG ating 37571 lm 296.4 W
More informationCERTIFIED TEST REPORT No
Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY ANGLE MEAN CP LUMENS
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
2.2.5 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 10 foot mounting height. REPORT NUMBER: RAB00701 ISSUE DATE: 02/04/15 PAGE: 1 OF 8 CATALOG NUMBER: VXLED26NDG / VXBRLED26NDG LUMINAIRE:
More informationLightLab I N T E R N A T I O N A L
Report of Test 13232-2 Performance Summary Total Light Output Luminaire Power Luminous Efficacy 3287 lm 35.6 W 92.3 lm/w PREPARED FOR : Ecolite Manufacturing, 9919 East Montgomery, Spokane, WA 99206. Page
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number 71622 UPC Number 60198671622 Description LED Ultra Thin Recessed Canopy Fixture 40W Voltage: 120/208/240/277 Shown with optional recessed mounting Bezel/Trim Cat# 71620 QPL ID # P29AE57D
More informationLED Volumetric Luminaires
LED Volumetric Luminaires Limitless Options for the following applications: When appearance is most important, TCP s LED Volumetric Luminaires turn any location into something truly exceptional. The precision-formed
More informationPHONE: (303) FAX: (303) WEBSITE:
REPORT NUMBER: ITL71484 PAGE: 1 OF 7 CATALOG NUMBER: LFLED5 / LFLED5BR / LFLED5MBR (FLOOD SERIES) LUMINAIRE: CAST METAL HOUSING, CAST METAL CIRCUIT BOARD MOUNTING BASE, ONE CIRCUIT BOARD WITH ONE LED,
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 15 foot mounting height. REPORT NUMBER: RAB01308 ISSUE DATE: 10/21/15 PAGE: 1 OF 9 DATE SAMPLE TESTED: 10/21/15 CATALOG NUMBER: HAZXLED42FDG
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0013 E-WP6L03CZ Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:
More informationLightLab I N T E R N A T I O N A L
Report of Test LL18297 Performance Summary Emergency Classification Luminous flux 89.6 lm Luminaire Power 1.05 W C0 D10 Luminous Efficacy 85.6 lm/w PREPARED FOR : Atom Lighting Ltd., Arundel, QLD 4214.
More informationLightLab I N T E R N A T I O N A L
Report of Test LL18299 Performance Summary Emergency Classification Luminous flux 87.6 lm Luminaire Power 1.14 W C0 D10 Luminous Efficacy 76.9 lm/w PREPARED FOR : Atom Lighting Ltd., Arundel, QLD 4214.
More informationChecked X.CAO
REPORT NUMBER: RAB02141 PAGE: 1 OF 7 CATALOG NUMBER: PIP30/D10 LUMINAIRE: ONE-PIECE CAST METAL HOUSING WITH PAINTED BRONZE FINISH, LED AND DRIVER COMPARTMENT SEPARATED BY FINNED HEAT SINK, ONE WHITE CIRCUIT
More informationNVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.
LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K
More informationChecked X.CAO
REPORT NUMBER: RAB02143 PAGE: 1 OF 7 CATALOG NUMBER: PIP15/D10 LUMINAIRE: ONE-PIECE CAST METAL HOUSING WITH PAINTED BRONZE FINISH, LED AND DRIVER COMPARTMENT SEPARATED BY FINNED HEAT SINK, ONE WHITE CIRCUIT
More informationGeometrical diameter, height = m = m. Geometrical diameter, height = m = m CIE code =
flux Product Description MBS0 GLOSS 36D Status = Released Measurement code = LVC0706 Measurement date = 007-07-0 Origin Brand = Philips Family name = Mini Fixed Family code = FUGATO Main application =
More informationLighting Sciences
Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY OUTPUT BEAM SIDE LUMENS
More informationPhotometric Report. 42 Partners Limited 21 Woden Road Wolverhampton WV10 0AU UK
42 Partners Limited 21 Woden Road Wolverhampton WV10 0AU UK www.42partners.com 42@42partners.com T +44 (0) 1902 453650 F +44 (0) 8721 153400 Registered in England: Company Number 3021552 VAT Registration
More informationNVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )
LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement
More informationStandard-Tech Co. Ltd Testing Center
Test Datasheet Test Location: [ ] 1. B802, No.11 Caipin Road, Guangzhou Science City, Guangzhou, [ ] Guangdong, China 2. R108, 1 st Floor No.69 GuangPu West Road, Guangzhou Science City, Guangzhou, Guangdong,
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08073-001A S-DL6-63L-27K w_s-dl6t-w-ss-c Date: 05/09/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationLM-79 Report TEST REPORT NO. L523A
LM-79 Report TEST REPORT NO. L523A Test Result Summary Luminaire Manufacturer Pioneer Engineering Inc. Luminaire Model Number S ST-0246-5L-5K-120 Input Voltage RMS (V) 120.03 Input Current RMS (A) 0.28
More informationHotel Hallway Analysis
Date: Operator: Blacksburg, VA 260 Telephone 5.553.6171 Table of contents Hotel Hallway Analysis Project Cover 1 Table of contents 2 ZUMTOBEL STAFF LIGHTING S5D7108 7108RC S5; S5D; SPEC-5; FORMED STEE...
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
2.02.05 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 12 foot mounting height..01.005.002 REPORT NUMBER: RAB02670 ISSUE DATE: 11/08/16 PAGE: 1 OF 9 DATE SAMPLE TESTED: 11/08/16 CATALOG
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08048-001A S-DL4-15L-27K w_s-dl4t-w-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08047-001A S-DL6-11L-40K w_s-dl6t-m-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08044-001A S-DL4-11L-27K w_s-dl4t-w-ss-c Date: 04/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationLM-79 Report TEST REPORT NO.M037D
LM-79 Report TEST REPORT NO.M037D Test Result Summary Luminaire Manufacturer Luminaire Model Number Input Voltage RMS (V) 120.0 Input Current RMS (A) 0.231 Input Power (W) 27.47 Light Output (lm) 3524
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL08049-001A S-DL6-15L-27K w_s-dl6t-w-ss-c Date: 04/13/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08078-001B S-DL8-75L-27K w_s-dl8t-w-ss-c Date: 05/10/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationVerification Services Test Report
Customer Company & Address ARTEMIDE S.P.A. Via Bergamo 18 20010 Pregnana Milanese (MI) Manufacturer: Artemide S.P.A. Country of Origin: Italy Country of Export: N/A Product Category: TOLOMEO LED TAVOLO
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 577- Report Number: Model: PL87-1A S-DL8-5L-27K w_s-dl8t-w-ss-c Date: 5/9/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08050-001A S-DL4-15L-40K w_s-dl4t-m-ss-c Date: 05/1/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationNVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A
LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:
More informationNVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A
LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08058-001B S-DL4-34L-40K w_s-dl4t-m-ss-c Date: 05/3/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 1 5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 8 foot mounting height. 7 3/4 1 3/4 3 1/8.02 0 3 1/2.01.005
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL08597-001A ZR24M-40L-35K-10V-FD Date: 6/21/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side INDEPENDENT TESTING LABORATORIES, INC. 2 1 0 1.05.1 1.5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 20 foot
More informationNVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)
LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor
More informationNVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD
LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD
LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
2.005.01.02 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 16 foot mounting height..002 REPORT NUMBER: RAB01042 ISSUE DATE: 07/15/15 PAGE: 1 OF 8 DATE SAMPLE TESTED: 07/15/15 CATALOG NUMBER:
More informationNVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)
LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor
More informationLED Entryway Light RoHS
72508 LED Entryway Light RoHS QPL ID # PSMN8JUU Model: 72508 Input Voltage 120-277 VAC 60HZ Input Current 0.5A Max @120V Input Power 25W Power Factor PF 0.95 OVERALL LAMP PARAMETERS Luminance 3,121 LM
More informationNVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada
LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada Four-Foot Linear Replacement Lamps Model name(s): IR-T8-15W4FT16503500K IR-T8-15W4FT16504000K IR-T8-15W4FT16505000K
More informationCat# LED High Bay
Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 577- Report Number: Model: PL843-1A S-CT-MFB-5L-36D-3K-xx Date: 5/26/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tammy
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL07190-001A FP22-34L-40K-10V Date: 12/18/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: CESTL-2013-0154 BXSPRA*2FG-U** Date: 6/19/2013 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tim Henning Cree, Inc 4600
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL04023-001 CXBAxxM40K8 CXBA16N Date: 7/27/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers Cree,
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL04150-001 BXSPCxx3MEE40K-xxxxxx or Date: 8/8/2014 XSPCxx3MEE40K-xxxxxx Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL04091-001 BXSPCxx4MEE30K-xxxxxx or XSPCxx4MEE30Kxxxxxx Date: 8/5/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation
More informationLighting Sciences
Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 IESNA CUTOFF CLASSIFICATION: NON-CUTOFF 3 1/2" 7"
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code - Report Number: Model: PL-A HXB-A-UV-L-M-K-UL-xx-xxxx Date: // Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationNVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)
LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-13W-ID(X,
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL09635-001A LS8-100L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL08392-001B S-DL8-A-42L-27K-M w_s-dl8t-a-ss-c Date: 06/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL09633-001A LS4-50L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationLM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1
LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL03375-001 CPY250-A-xx-D-C-UL-xx-40K or Date: 03/24/2014 BXCCAxD04-UW7 or XCCAxD04-UW7 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation