1 REPORT NUMBER: ITL71484 PAGE: 1 OF 7 CATALOG NUMBER: LFLED5 / LFLED5BR / LFLED5MBR (FLOOD SERIES) LUMINAIRE: CAST METAL HOUSING, CAST METAL CIRCUIT BOARD MOUNTING BASE, ONE CIRCUIT BOARD WITH ONE LED, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH, BLACK RUBBER REFLECTOR MOUNTING COLLAR, CLEAR FLAT MICRO-PRISMATIC GLASS LENS IN CAST WHITE PAINTED METAL LENS FRAME. LENS PRISMS OUT. LAMP: ONE WHITE MULTI-CHIP LIGHT EMITTING DIODE (LED) CONTAINING LEDS ARRANGED IN AN ARRAY OF 3 LINEAR VERTICAL ROWS, LEDS AIMED AT THE HORIZON. TOTAL INPUT WATTS = 5.11 AT 12 VOLTS LED DRIVER: LINKCOM BPHE005C401 NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE LED DRIVER. LED DRIVER INFORMATION PROVIDED BY CLIENT. TEST PROCEDURE: IESNA LM TEST DISTANCE = FEET FLOODLIGHT CHARACTERISTICS IES TYPE 4H X 4V MAXIMUM CANDLEPOWER 570. AT H, -1 V HORIZONTAL BEAM ANGLE (50%) 43.8 deg VERTICAL BEAM ANGLE (50%) 43.9 deg HORIZONTAL FIELD ANGLE (10%) 64.5 deg VERTICAL FIELD ANGLE (10%) 63.6 deg BEAM LUMENS (% FIXTURE) 208. ( 69.5 % ) FIELD LUMENS (% FIXTURE) 276. ( 92.5 % ) TOTAL LUMENS (% FIXTURE) 299. (10 % ) EFFICACY = 58.5 Lm/W Checked Approved 2 B HYRE R BEATTIE Lighting Engineer 2 1/2 AXIAL CANDLEPOWER DEG HORIZ. DEG VERT ALL CANDELA AND LUMEN VALUES IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY.

2 REPORT NUMBER: ITL71484 PAGE: 2 OF 7 CANDELA TABULATION AVERAGE OF RIGHT AND LEFT SIDES BEAM EDGE = FIELD EDGE = 285. CP = 50% OF MAX 57. CP = 10% OF MAX

3 REPORT NUMBER: ITL71484 PAGE: 3 OF 7 CANDELA TABULATION - FIELD ONLY AVERAGE OF RIGHT AND LEFT SIDES BEAM EDGE = FIELD EDGE = 285. CP = 50% OF MAX 57. CP = 10% OF MAX

4 REPORT NUMBER: ITL71484 PAGE: 4 OF 7 LUMEN TABULATION AVERAGE OF RIGHT AND LEFT SIDES TOTAL LUMEN TOTAL THIS PAGE = 149.4

5 REPORT NUMBER: ITL71484 PAGE: 5 OF 7 LUMEN TABULATION - FIELD ONLY AVERAGE OF RIGHT AND LEFT SIDES TOTAL LUMEN TOTAL THIS PAGE = 138.2

6 REPORT NUMBER: ITL71484 PAGE: 6 OF 7 ISOCANDELA CURVES AVERAGE OF RIGHT AND LEFT SIDES (= 50% MAX) (= 10% MAX)

7 REPORT NUMBER: ITL71484 PAGE: 7 OF 7 ADDRESS: 170 LUDLOW AVE NORTHVALE, NJ THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

8 REPORT NUMBER: ITL71490 Page 1 of 4 DATE: 01/23/12 CATALOG NUMBER: LFLED5 / LFLED5BR / LFLED5MBR (FLOOD SERIES) ADDRESS: LUMINAIRE: LAMP: DRIVER: ORIENTATION IN SPHERE: NOTE: 170 LUDLOW AVE NORTHVALE, NJ CAST METAL HOUSING, CAST METAL CIRCUIT BOARD MOUNTING BASE, ONE CIRCUIT BOARD WITH ONE LED, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH, BLACK RUBBER REFLECTOR MOUNTING COLLAR, CLEAR FLAT MICRO-PRISMATIC GLASS LENS IN CAST WHITE PAINTED METAL LENS FRAME. LENS PRISMS OUT. ONE WHITE MULTI-CHIP LIGHT EMITTING DIODE (LED) CONTAINING LEDS ARRANGED IN AN ARRAY OF 3 LINEAR VERTICAL ROWS, LEDS AIMED AT THE HORIZON. LINKCOM BPHE005C401 AIMED AT HORIZON DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE LED DRIVER. LED DRIVER INFORMATION PROVIDED BY CLIENT. Calibration Due: INSTRUMENTS: Kikusui PCR500L AC Power Source N/A Yokogawa WT210 Digital Power Meter #4 04/04/12 Optronic Laboratories OL770 Spectroradiometer 03/24/12 ITL 1.5 meter Diameter Integrating Sphere, 4PI Geometry 03/24/12 OBJECT OF TEST: PROCEDURE: RESULTS: Measure the Absolute Flux in lumens*, Total Radiant Flux*, Spectral Power Distribution (SPD), Correlated Color Temperature (CCT), Color Rendering Indices (CRIa,1-14), Chromaticity Coordinates (x,y; u v ), ANSI C Duv, and electrical data including Power Factor (PF) and Total Harmonic Distortion (THD) to the test sample. Report Off-State Power. The test sample was provided by the customer and had an unknown number of burn hours. The test sample was mounted inside the integrating sphere and allowed to stabilize. After stabilization occurred, measurements were taken. In order to measure mean performance, multiple data sets were recorded and averaged. Readings were taken with the test sample operating at 120VAC input in a 25 +/-1 degree Celsius free air ambient and in accordance with IESNA LM All data are traceable to the National Institute of Standards and Technology. Off-State Power was reported with no voltage applied to the sample. (continued subsequent pages) THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT. Checked Approved T BERGER N GULLY Lighting Engineer

9 REPORT NUMBER: ITL71490 Page 4 of 4 DATE: 01/23/12 CATALOG NUMBER: LFLED5 / LFLED5BR / LFLED5MBR (FLOOD SERIES) CIE Chromaticity Diagram

10 REPORT NUMBER: ITL71490 Page 2 of 4 DATE: 01/23/12 CATALOG NUMBER: LFLED5 / LFLED5BR / LFLED5MBR (FLOOD SERIES) RESULTS: PHOTOMETRIC Total Integrated Flux (lumens) * SPECTRORADIOMETRIC Observer Chromaticity Ordinate x Chromaticity Ordinate y Observer Chromaticity Ordinate u Chromaticity Ordinate v Correlated Color Temp CCT (K) Color Rendering Index (CRIa) Color Rendering Index 1 (Light greyish red) Color Rendering Index 2 (Dark greyish yellow) Color Rendering Index 3 (Strong yellowish green) Color Rendering Index 4 (Moderate yellowish green) Color Rendering Index 5 (Light bluish green) Color Rendering Index 6 (Light blue) Color Rendering Index 7 (Light violet) Color Rendering Index 8 (Light reddish purple) Color Rendering Index 9 (Strong red) Color Rendering Index 10 (Strong yellow) Color Rendering Index 11 (Strong green) Color Rendering Index 12 (Strong blue) Color Rendering Index 13 (Light yellowish pink (skin)) Color Rendering Index 14 (Moderate olive green (leaf)) ANSI C Duv Total Radiant Flux (milliwatts) CIE degree CIE degree *NOTE: ELECTRICAL FOR SPECTRORADIOMETRIC TEST Input Voltage (Volts AC ) Input Current (Amps AC ) Input Power (Watts) Input Power Factor (%) Input Current THD (%) Input Voltage THD (%) Off-State Power (Watts) Proper calibration of integrating spheres for measuring total flux output of non-directional samples will produce reliable, repeatable results within the calibration tolerances of the equipment used. However, measurement of test samples with significant self absorption and/or directional output, even when these effects are compensated for, are likely to have a greater variation in results compared to the flux output calculated from a goniophotometric exploration since these artifacts do not affect the goniophotometric results.

11 THE LIGHT CENTER OF THE INDUSTRY SINCE LONGHORN ROAD, BOULDER, CO USA REPORT NUMBER: ITL71490 Page 3 of 4 DATE: 01/23/12 CATALOG NUMBER: LFLED5 / LFLED5BR / LFLED5MBR (FLOOD SERIES) RESULTS: Wavelength mw per nm Wavelength mw per nm Wavelength mw per nm Output vs. Wavelength 6.6 Output (mw/nm) Wavelength (nm)

Checked X.CAO

Checked X.CAO REPORT NUMBER: RAB02141 PAGE: 1 OF 7 CATALOG NUMBER: PIP30/D10 LUMINAIRE: ONE-PIECE CAST METAL HOUSING WITH PAINTED BRONZE FINISH, LED AND DRIVER COMPARTMENT SEPARATED BY FINNED HEAT SINK, ONE WHITE CIRCUIT

More information

Checked X.CAO

Checked X.CAO REPORT NUMBER: RAB02143 PAGE: 1 OF 7 CATALOG NUMBER: PIP15/D10 LUMINAIRE: ONE-PIECE CAST METAL HOUSING WITH PAINTED BRONZE FINISH, LED AND DRIVER COMPARTMENT SEPARATED BY FINNED HEAT SINK, ONE WHITE CIRCUIT

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 1 5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 8 foot mounting height. 7 3/4 1 3/4 3 1/8.02 0 3 1/2.01.005

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Transverse Distance in Units of Mounting Heights Street Side House Side INDEPENDENT TESTING LABORATORIES, INC. 2 1 0 1.05.1 1.5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 20 foot

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2.02.05 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 12 foot mounting height..01.005.002 REPORT NUMBER: RAB02670 ISSUE DATE: 11/08/16 PAGE: 1 OF 9 DATE SAMPLE TESTED: 11/08/16 CATALOG

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2.2.5 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 10 foot mounting height. REPORT NUMBER: RAB00701 ISSUE DATE: 02/04/15 PAGE: 1 OF 8 CATALOG NUMBER: VXLED26NDG / VXBRLED26NDG LUMINAIRE:

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 15 foot mounting height. REPORT NUMBER: RAB01308 ISSUE DATE: 10/21/15 PAGE: 1 OF 9 DATE SAMPLE TESTED: 10/21/15 CATALOG NUMBER: HAZXLED42FDG

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2.005.01.02 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 16 foot mounting height..002 REPORT NUMBER: RAB01042 ISSUE DATE: 07/15/15 PAGE: 1 OF 8 DATE SAMPLE TESTED: 07/15/15 CATALOG NUMBER:

More information

LM-79 Report TEST REPORT NO. L523A

LM-79 Report TEST REPORT NO. L523A LM-79 Report TEST REPORT NO. L523A Test Result Summary Luminaire Manufacturer Pioneer Engineering Inc. Luminaire Model Number S ST-0246-5L-5K-120 Input Voltage RMS (V) 120.03 Input Current RMS (A) 0.28

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: RESTL-2013-0012 E-HL6S11CSZ Date: 11/08/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Joshua Krohn Cree,

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0008 E-GL4S03C2K Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

LM-79 Report TEST REPORT NO.M037D

LM-79 Report TEST REPORT NO.M037D LM-79 Report TEST REPORT NO.M037D Test Result Summary Luminaire Manufacturer Luminaire Model Number Input Voltage RMS (V) 120.0 Input Current RMS (A) 0.231 Input Power (W) 27.47 Light Output (lm) 3524

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06411-001A CPY250-A-xx-F-D-UL-40K-xxxx or BXCCAxA17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05591-001B CPY250AxxFB-UL40Kxxxx / BXCCAxA13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03375-001 CPY250-A-xx-D-C-UL-xx-40K or Date: 03/24/2014 BXCCAxD04-UW7 or XCCAxD04-UW7 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0013 E-WP6L03CZ Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06410-001A CPY250-A-xx-D-D-UL-40K-xxxx or BXCCAxD17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

Morris Products 53 Carey Road, Queensbury, NY 12804

Morris Products 53 Carey Road, Queensbury, NY 12804 Catalog Number 71622 UPC Number 60198671622 Description LED Ultra Thin Recessed Canopy Fixture 40W Voltage: 120/208/240/277 Shown with optional recessed mounting Bezel/Trim Cat# 71620 QPL ID # P29AE57D

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05642-001B CPY250AxxDB-UL40Kxxxx / BXCCAxD13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04023-001 CXBAxxM40K8 CXBA16N Date: 7/27/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers Cree,

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B/N FLS20U45B/N FLS20U50B/N FLS20U40W/N FLS20U45W/N

More information

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B FLS20U45B FLS20U50B FLS20U40W FLS20U45W FLS20U50W

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS40U40B FLS40U45B FLS40U50B FLS40U40W FLS40U45W FLS40U50W

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl5s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Dec.05,2016 Review By: Manager: Tommy Liang Note:

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl4s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Mar. 01,2017 Review By: Manager: Tommy Liang

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For MaxLite Inc 10 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x146,

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0031 BXSPWA02MC-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0032 BXSPWA03MG-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL04091-001 BXSPCxx4MEE30K-xxxxxx or XSPCxx4MEE30Kxxxxxx Date: 8/5/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04150-001 BXSPCxx3MEE40K-xxxxxx or Date: 8/8/2014 XSPCxx3MEE40K-xxxxxx Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: ) LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10604-001A CPY250-B-xx-F-A-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) LM-79-08 Test Report For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) 7 F, Jinchangda Industrial Park,zhangkengjing,GuanLan, Baoao,Shenzhen,Guangdong,China 2x2 Luminaires for Ambient Lighting of Interior

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10609-001A CPY250-B-xx-F-F-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Maxlite Jersey Blvd Rancho Cucamonga, CA Electrical and Photometric tests as required by the IESNA test standards.

Maxlite Jersey Blvd Rancho Cucamonga, CA Electrical and Photometric tests as required by the IESNA test standards. Test #: L02144405 Date: 2/21/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L02144405 LSU2406U2050 / DV50 Report Prepared

More information

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 ZOHO Series LED Flood Light Model name(s): BLTFLD50W5K Representative (Tested)

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07860-001B BXSPR-HO-xx-5SH-60W-40K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08073-001A S-DL6-63L-27K w_s-dl6t-w-ss-c Date: 05/09/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

LED Entryway Light RoHS

LED Entryway Light RoHS 72508 LED Entryway Light RoHS QPL ID # PSMN8JUU Model: 72508 Input Voltage 120-277 VAC 60HZ Input Current 0.5A Max @120V Input Power 25W Power Factor PF 0.95 OVERALL LAMP PARAMETERS Luminance 3,121 LM

More information

Cat# LED High Bay

Cat# LED High Bay Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03402-001 BXOSQAxx4MES40K Date: 04/15/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Brandon Bitner Cree,

More information

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es) LM-79-08 Test Report For LED Wav es,inc (Brand Name: LED Wav es) 4100 1st Ave,The Esquire Building,Brooklyn, NY 11232 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): SL2-2X2-40W-11

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL843-1A S-CT-MFB-5L-36D-3K-xx Date: 5/26/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tammy

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07611-001A BXSPR-HO-HT-3ME-60W-57K-UL Date: 04/08/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07609-001B BXSPR-HO-HT-3ME-60W-30K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08049-001A S-DL6-15L-27K w_s-dl6t-w-ss-c Date: 04/13/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada Four-Foot Linear Replacement Lamps Model name(s): IR-T8-15W4FT16503500K IR-T8-15W4FT16504000K IR-T8-15W4FT16505000K

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08048-001A S-DL4-15L-27K w_s-dl4t-w-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08047-001A S-DL6-11L-40K w_s-dl6t-m-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08044-001A S-DL4-11L-27K w_s-dl4t-w-ss-c Date: 04/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL87-1A S-DL8-5L-27K w_s-dl8t-w-ss-c Date: 5/9/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08270-001A BXSPR-HO-HT-3ME-60W-57K-UL w/ XA-SPR3BLS Date: 05/07/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08050-001A S-DL4-15L-40K w_s-dl4t-m-ss-c Date: 05/1/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08078-001B S-DL8-75L-27K w_s-dl8t-w-ss-c Date: 05/10/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Report No.: GZE150726-B LM-79-08 Test Report For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Four-Foot Linear Replacement Lamps Model name(s): IGTTU-1501850F-4BC

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08058-001B S-DL4-34L-40K w_s-dl4t-m-ss-c Date: 05/3/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09294-001A ARE-EDG-3M-xx-06-E-UL-xx-700-xxxx Date: 09/14/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09285-001 ARE-EDG-5M-xx-06-E-UL-xx-700-xxxx-40K Date: 09/13/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08391-001A S-DL8-A-34L-27K-M w_s-dl8t-a-ss-c Date: 05/26/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08381-001A S-DL4-A-42L-35K-M w_s-dl4t-a-ss-c Date: 05/24/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08388-001A S-DL6-A-42L-27K-M w_s-dl6t-a-ss-c Date: 05/19/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions. Report No: L031603401 Date: 3/15/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L0031603401 Report Prepared For: Osram Sylvania, Inc. Model

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: CESTL-2013-0154 BXSPRA*2FG-U** Date: 6/19/2013 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tim Henning Cree, Inc 4600

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08392-001B S-DL8-A-42L-27K-M w_s-dl8t-a-ss-c Date: 06/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04395-001 BXSPRBxx3MEA30K-xxxxxx or XSPRBxx3MEA30K-xxxxxx Date: 9/09/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W LM-79-08 Test Report For MaxLite Inc. 12 York Ave West Caldwell NJ 07006, USA LED Commercial Down lights Model: RR82540W Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-22W-ID(X,Clear)

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT8N20-A Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08254-001A S-DL4-A-42L-40K-W w_s-dl4t-a-ssc Date: 04/27/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10023-003B ARE-EDG-2MB-xx-06-E-UL-xx-525-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL06803-001A BPAR30S-0803040C-12DE26-1C100 Date: 9/26/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-13W-ID(X,

More information

Report No.: HZ p. (Lumens) Stabilization Time CRI (K)

Report No.: HZ p. (Lumens) Stabilization Time CRI (K) Test Summary Sample Tested: ML2LA23LTRBNI827 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 73.6 1737.0 23.61 0.9872 CCT Stabilization Time CRI (K) (Light & Power)

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL06982-001A BPAR30L-0803025C-12DE26-1C100 Date: 10/6/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10142-001B FLD-EDG-SN-xx-06-E-UL-xx-700-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05401-001 RULHT2MEC40K-12xxx Date: 02/11/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Bernard Krauska

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6 LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-6 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9 LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-9 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000795-001A Catalog Number: GTSOL112-G2-HO-BR-NL Two Mean Well HLG-240H-C2100B LED drivers 120.0Vac, 60.00Hz, 2.811A, 335.1W, 0.994PF, 5.5%THD(i) Total Light Output Luminaire Power Luminous

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09245-001A SPAR38-1503025TD-12DE26-1 Date: 9/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For DONGBU LIGHTEC CO. LTD 14, Saneop-ro 104beon-gil, Ojeong-gu, Bucheon-si, Gyeongg-do, Korea

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL07190-001A FP22-34L-40K-10V Date: 12/18/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS 71400A GAS STATION Canopy Luminaire Wet Locations Use QPL ID # PL9D2UU8ZA41 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T March 26, 2012 Title: TEMPO 21 Report Prepared for: Sviazinvest, OJSC Prepared by: Cree Durham Technology Center (DTC) Ticket Number: 10806-T Co NVLAP lab code 500070-0 The accreditation of the Cree Durham

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08597-001A ZR24M-40L-35K-10V-FD Date: 6/21/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02 Report No: L041608003 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608003 Report Prepared For: GM LIGHTING 9830 W 190th St,

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000998-002A Catalog Number: ML5WL-D-HO-ASY-K40-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 720mA. Total Light Output Luminaire Power Luminous Efficacy

More information

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02 Report No: L041608103 Date: 4/28/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608103 Report Prepared For: GM LIGHTING 9830 W 190th St,

More information