Photometric Report. 42 Partners Limited 21 Woden Road Wolverhampton WV10 0AU UK

Size: px
Start display at page:

Download "Photometric Report. 42 Partners Limited 21 Woden Road Wolverhampton WV10 0AU UK"

Transcription

1 42 Partners Limited 21 Woden Road Wolverhampton WV10 0AU UK T +44 (0) F +44 (0) Registered in England: Company Number VAT Registration Number: GB Photometric Report

2 Photometric Report Pictures Luminaire information Report basis Polar Curves HV Distribution Curves Principal Axes Intensities Light Output Ratios & CIBSE TM5 Results Luminous intensities Zonal Flux Calculations Beam Distribution Analysis Luminance calculations VDT Luminance table CIBSE TM10 Glare Index Results CIE Glare Limiting (Soellnor) Diagram Comments Quick Design Table

3

4

5

6 Luminaire physical characteristics Overall Dimensions Length 595mm Width 105mm Height 105mm Visible Dimensions when installed Length 595mm Width 105mm Height 0mm Luminous Dimensions Length 580mm Width 580mm Height 0 0mm Height 90 0mm Height 180 0mm Height 270 0mm Luminous Areas Base m 2 Sides 0m 2 ( 0 /180 azimuth) Ends 0m 2 (90 /270 azimuth)

7 Report Basis All measurements taken in accordance with EN13032 / IES-NA-LM-79. Source tests were performed with the luminaire in a horizontal, panel down orientation with the panel removed. Luminaire tests were performed with the luminaire in a horizontal, panel down orientation. The photometric centre of the luminaire was taken as the geometric centre of the front face of the luminaire. The photometric nadir was taken to be perpendicular to the front face of the luminaire. The luminaire has been treated as though it is rotationally symmetric. The lumen output, light output ratio (LORL) and power consumption of the luminaire were determined at 25 C after 100 hours pre-conditioning. The LED cluster was treated as an integral part of the luminaire.

8 Electrical input & Photometric output characteristics Sample Voltage Current Power Power VA Output % of Efficacy (V) (ma) Factor (W) (lm) Nominal (lm/w) Luminaire ,575 59% 64.2 Source Total ,737 85% 92.8 Electrical characteristics at 25 C Source Nominal 230V 154.8mA 1.00PF 35.6W 35.6VA Luminaire 230V 181.1mA 0.96PF 40.1W 41.7VA Source Total 230V 182.0mA 0.96PF 40.3W 41.9VA Measured Electrical characteristics relative to Source Nominal Luminaire Current 117% Power 113% VA 117% Source Total Current 118% Power 113% VA 118% Lumen Output figures used in this report (lumens) Nominal Source Total Output 4,400 Measured Luminaire Output 2,575 Measured Source Total Output 3,738 Measured Lumen Output characteristics relative to Source Nominal Total Luminaire 59% Source Total 85% Measured luminous efficacy at 25 C Luminaire 64.2 lm/w Source Total 92.8 lm/w

9 The light output ratio of the luminaire was measured as at 25 C. This is the ratio of the output of the luminaire to the output of the luminaire with the cover removed. The measured lumen output of the luminaire was 2,575 lumens at 25 C. This figure can be related to the total nominal lumen output of the sources quoted by the manufacturer of 4,400 (2 * 2,200 ) lumens, to give a nominal light output ratio of The total measured lumen output of the sources (the luminaire with the cover removed) was 3,738 lumens at 25 C. This figure can be related to the total nominal lumen output of the sources quoted by the manufacturer of 4,400 (2 * 2,200 ) lumens, to give a nominal BLF of For lighting design calculations: A light output ratio of 1 should be used in conjunction with the measured lumen output of the luminaire of 2,575 lumens. or The nominal light output ratio of should be used in conjunction with the nominal lumen output of the sources of 4,400 (2 * 2,200 ) lumens. or The measured light output ratio of should be used in conjunction with the total measured lumen output of the sources of 3,738 (2 * 3,737 ) lumens. or The measured light output ratio of should be used in conjunction with the nominal lumen output of the sources of 4,400 (2 * 2,200 ) lumens and the nominal BLF of This report is based on the following parameters: The Light Output Ratio is the nominal value of The source output is the nominal value of 2,200 lumens. There are 2 sources in the luminaire.

10 Average Principal Axes Luminous Intensities (cd/klm)

11 Average Principal Axes Luminous Intensities (cd)

12 Average Principal Axes Luminous Intensities (cd/klm)

13 Average Principal Axes Luminous Intensities (cd)

14 Average Luminous Intensities (cd/klm) Angle All planes

15 Average Luminous Intensities (cd) Angle All planes

16 Light Output Ratios Up 0.00 Down 0.59 Total 0.59 Spacing to Height Ratios SHR NOM 1.25 SHR MAX 1.47 Utilisation Factors UF(F) Standard Presentation SHR NOM = 1.25 Room Reflectances Room Index C W F BZ Class CIE Flux code 47 / 79 / 95 / 100 / 59 CIE Room Index CIE DRR CIE class 5 / 5 / 5 / 5 / 5 / 5 / 5 / 5 / 5 / 5 / 5 / 5 Flux Fraction Ratio 0.00 DIN Class 0.59 A Calculated in accordance with CIBSE Technical Memorandum No In accordance with TM5, this UF table is valid for values of SHR from 0.5 below SHR NOM to 0.5 above SHR NOM. SHR MAX is a separate limitation. Reflectances given in the UF table are the effective reflectances of the ceiling cavity, walls and floor cavity, and must be determined for the actual room in which the luminaire will be used. UF(F),UF(W), and UF(C) for 0% reflectance of the room surfaces are equivalent to DF(F),DF(W) and DF(C) respectively.

17 Averaged Luminous Intensities (Cd/Klm) Elevation( ) Azimuth( )

18 Non averaged Luminous Intensities (Cd/Klm) Elevation( ) Azimuth( ) Elevation( ) Azimuth( )

19 Non averaged Luminous Intensities (Cd/Klm) Elevation( ) Azimuth( ) Elevation( ) Azimuth( )

20 Averaged Luminous Intensities (Cd) Elevation( ) Azimuth( )

21 Non averaged Luminous Intensities (Cd) Elevation( ) Azimuth( ) Elevation( ) Azimuth( )

22 Non averaged Luminous Intensities (Cd) Elevation( ) Azimuth( ) Elevation( ) Azimuth( )

23 Zonal Flux Calculations Angles Individual Cumulative % 0.8% % 3.3% % 7.3% % 12.7% % 19.3% % 26.9% % 35.3% % 44.2% % 53.2% % 62.2% % 70.7% % 78.5% % 85.3% % 91.0% % 95.2% % 98.1% % 99.6% % 100.0%

24 Beam Distribution Analysis Average All Planes Analysis according to Beam Centre / Beam Peak 50% of Beam Peak at 0.0 is a Half Peak Beam Angle of 56.8 (57 nominal) giving a Beam Width of (114 nominal). 10% of Beam Peak at 0.0 is a One Tenth Peak Spread Angle of 81.1 (81 nominal) giving a Beam Spread of (162 nominal).

25 Averaged Luminance Values (cd/m 2 ) Elevation( ) Azimuth( )

26 Non averaged Luminance Values (cd/m 2 ) Elevation( ) Azimuth( )

27 Averaged Luminance Values (cd/m 2 /klm) Elevation( ) Azimuth( )

28 Non averaged Luminance Values (cd/m 2 /klm) Elevation( ) Azimuth( )

29 Maximum Non averaged Luminance Values (cd/m 2 ) Elevation( ) Maximum Azimuth Angle

30 VDT Luminance Information BS EN (2002) / CIBSE LG7 (2005) / CIBSE LG3 (2001) Permitted Usage according to Limiting Use permitted at Screen Type and Luminance Limit Angle luminance Luminance Limit (cd/m 2 ) Angle( ) Screen Type III (No screen treatment) 200 NO NO used with some negative polarity software Screen Type I and II (Good or moderate screen treatment) 500 NO NO used with some negative polarity software Screen Type III (No screen treatment) 1000 NO NO used with only positive polarity software Screen Type I and II (Good or moderate screen treatment) 1500 NO NO used with only positive polarity software VDT Luminance Information BS EN (2011) / CIBSE LG7 (2012) Permitted Usage according to Limiting Use permitted at Screen Type and Luminance Limit Angle luminance Luminance Limit (cd/m 2 ) Angle( ) Medium luminance screen ( L <= 200 cdm 2 ) Case B NO negative polarity and/or higher requirements Medium luminance screen ( L <= 200 cdm 2 ) Case A NO positive polarity and normal requirements High luminance screen ( L > 200 cd/m2 ) Case B NO negative polarity and/or higher requirements High luminance screen ( L > 200 cd/m2 ) Case A YES positive polarity and normal requirements

31 Uncorrected Glare Indices Reflectance of Ceiling Wall Floor Cavity Room dimension X Y Viewed All Planes 2H 2H H H H H H H 2H H H H H H H 4H H H H H 4H H H Calculated in accordance with CIBSE Technical Memorandum No

32 CIE Glare Limiting (Soellnor) Diagram Glare Quality Service values of illuminance Rating Class 1.15 A < B < C < D < E <300 a b c d e f g h L (cd/m 2 )

33 Comments It is recommended that point to point calculations are used when designing lighting schemes in order to accurately predict uniformity. Data files in various formats are available to allow easy transfer of this data to a computer. Please enquire for details.

34 Quick Design Table Based on: reflectances of Ceiling = 0.5 Wall = 0.5 Floor = 0.2 Room Index = 2.00 lamp output = 2200 lumens ballast lumen factor = 1.00 To achieve an Illuminance of 100 lux Surface Area (m 2 ) No. of luminaires

UNIVERSITY OF HONG KONG Faculty of Engineering M.Sc.(Eng) in Building Services Engineering MEBS6002 LIGHTING ENGINEERING

UNIVERSITY OF HONG KONG Faculty of Engineering M.Sc.(Eng) in Building Services Engineering MEBS6002 LIGHTING ENGINEERING The following table for rule 2 specifies recommended shielding angles for cut-off type luminaires. Some manufacturers in UK provide data for the CIE method in a graphical form. The degree of glare is assessed

More information

Chartered Institute of Building Service Engineers (CIBSE) code for interior lighting design

Chartered Institute of Building Service Engineers (CIBSE) code for interior lighting design Chartered Institute of Building Service Engineers (CIBSE) code for interior lighting design The maintenance factor gives an estimate of how lighting conditions will deteriorate through everyday use. Dust

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL15785 Performance Summary Luminous flux 540 lm Bare Lamp Power 7.76W SHR Nominal 0.75 SHR Maximum 0.79 PREPARED FOR : Indice Ecotech Pty. Ltd., Richmond, VIC 3121. Page 1 of 7 Performance

More information

Efficiency 82.31% Coordinate system CG Roads Total Flux lm. Maximum value cd/klm Position C=10.00 G=55.00 Sym.

Efficiency 82.31% Coordinate system CG Roads Total Flux lm. Maximum value cd/klm Position C=10.00 G=55.00 Sym. Maximum value 80.31 cd/klm Position C=10.00 G=55.00 Sym. on planes 270-90 Rectangular Luminaire Length 770 mm Width 370 mm Height 205 mm Rectangular Luminous Area Length 290 mm Width 230 mm Height 0 mm

More information

: Office. Project number : Customer : SLP UK Ltd Processed by : RH Date : Project description:

: Office. Project number : Customer : SLP UK Ltd Processed by : RH Date : Project description: Office Customer : SLP UK Ltd Processed by : RH Project description: The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000792-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 9457 lm 78.6 W 120.3 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL 34135,

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000792-003 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 8616 lm 70.3 W 122.6 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL 34135,

More information

SUPPLE Table lamp. Material Aluminium Steel Polycarbonate. Finish White lacquered Transparent IP20 ±180º 1 TECHNICAL CHARACTERISTICS

SUPPLE Table lamp. Material Aluminium Steel Polycarbonate. Finish White lacquered Transparent IP20 ±180º 1 TECHNICAL CHARACTERISTICS SUPPLE Table lamp Designer: Josep Patsí 10-4415-78-M2 V0 Finish White lacquered Transparent Material Aluminium Steel Polycarbonate IP20 ±180º 1 TECHNICAL CHARACTERISTICS Light source Light source: LED

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000795-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 35087 lm 296.1 W 118.5 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL

More information

Geometrical diameter, height = m = m. Geometrical diameter, height = m = m CIE code =

Geometrical diameter, height = m = m. Geometrical diameter, height = m = m CIE code = flux Product Description MBS0 GLOSS 36D Status = Released Measurement code = LVC0706 Measurement date = 007-07-0 Origin Brand = Philips Family name = Mini Fixed Family code = FUGATO Main application =

More information

TECHNICAL CHARACTERISTICS. IK Protection degrees: Total power consumption (W): 1.7W. Warranty (Years): 2. Option to extend the guarantee (Years): 5

TECHNICAL CHARACTERISTICS. IK Protection degrees: Total power consumption (W): 1.7W. Warranty (Years): 2. Option to extend the guarantee (Years): 5 OUT XENA 55-9424-4-T2 TECHNICAL CHARACTERISTICS Type: IP Protection degrees: IK Protection degrees: Light source 1: UPLIGHT RECESSED IP67 IK10 12 x LED 1W Neutral white - 4000K 128 lm (N) Total power consumption

More information

TECHNICAL CHARACTERISTICS. IK Protection degrees: Total power consumption (W): 0.9W. Warranty (Years): 2. Option to extend the guarantee (Years): 5

TECHNICAL CHARACTERISTICS. IK Protection degrees: Total power consumption (W): 0.9W. Warranty (Years): 2. Option to extend the guarantee (Years): 5 OUT XENA 55-9424-4-MV1 TECHNICAL CHARACTERISTICS Type: IP Protection degrees: IK Protection degrees: Light source 1: UPLIGHT RECESSED IP67 IK10 12 x LED 1W Neutral white - 4000K 128 lm (N) Total power

More information

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R-LL-00-UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R-LL-00-UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File) DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] 1008 [UL TEST] 11750395.01 [ECN] 3056 [TESTLAB] UL Verification Services Inc. [ISSUEDATE] 5/4/2017 [MANUFAC] Tempo LLC [LUMCAT] C6R-LL-00-UNVE5-35-LG

More information

CA-37. GEA Downlight recessed. Description Ceiling-Eecessed for outdoor use.

CA-37. GEA Downlight recessed. Description Ceiling-Eecessed for outdoor use. 159665CA37 V0 GEA Downlight recessed Description CeilingEecessed for outdoor use. For downlighting. Adjustable light source. Structure material: Stainless steel AISI316. Structure finish: Polished. Diffuser

More information

Gear included: Yes, electronic Output (W): 19W. Voltage / Frequency:

Gear included: Yes, electronic Output (W): 19W. Voltage / Frequency: 1-2936-S2-M1 V0 TOLEDO Ceiling fixture Description Recessed light fitting for indoor use. For downlighting. Timeless design. Super slim. High performance W/effective lumens. Optimum priceperformance. High

More information

TECHNICAL CHARACTERISTICS. IK Protection degrees: Total power consumption (W): 0.9W. Warranty (Years): 2. Option to extend the guarantee (Years): 5

TECHNICAL CHARACTERISTICS. IK Protection degrees: Total power consumption (W): 0.9W. Warranty (Years): 2. Option to extend the guarantee (Years): 5 OUT XENA 55-943-34-M3V1 TECHNICAL CHARACTERISTICS Type: IP Protection degrees: IK Protection degrees: Light source 1: UPLIGHT RECESSED IP67 IK 1 x LED 1W Neutral white - 4000K 18 lm (N) Total power consumption

More information

DIALux simulation for indoor tennis court 300lux

DIALux simulation for indoor tennis court 300lux 2 indoor tennis courts Lamps mounted at 7M height 300lux at 1M above gound 8pcs lamps per court Partner for Contact: Order No.: Company: Customer No.: Date: Operator: Mr. Sander Revelman Table of contents

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: ) LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement

More information

REPORT NO. Projection Lighting Date of Issue: 12/10/11 (Life) Issue G. Description: LED Luminaire Status at: 11/10/11

REPORT NO. Projection Lighting Date of Issue: 12/10/11 (Life) Issue G. Description: LED Luminaire Status at: 11/10/11 T e s t R e p o r t REPORT NO. Projection Lighting Date of Issue: 12/10/11 (Life) Issue G Description: LED Luminaire Status at: 11/10/11 Type/Model: Alpha LED Date Received: 24/06/09 (35,000 hrs) Condition

More information

Report of Test LLIA

Report of Test LLIA eport of Test LLIA000858-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 14313 lm 107.5 W 133.1 lm/w PEPAED FO : Topaz Lighting Corp, 925 Waverly Avenue, Holtsville, NY 11742,

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000795-001A Catalog Number: GTSOL112-G2-HO-BR-NL Two Mean Well HLG-240H-C2100B LED drivers 120.0Vac, 60.00Hz, 2.811A, 335.1W, 0.994PF, 5.5%THD(i) Total Light Output Luminaire Power Luminous

More information

Hotel Hallway Analysis

Hotel Hallway Analysis Date: Operator: Blacksburg, VA 260 Telephone 5.553.6171 Table of contents Hotel Hallway Analysis Project Cover 1 Table of contents 2 ZUMTOBEL STAFF LIGHTING S5D7108 7108RC S5; S5D; SPEC-5; FORMED STEE...

More information

IES INDOOR REPORT PHOTOMETRIC FILENAME : SSLED4830-XX.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : SSLED4830-XX.IES. DESCRIPTION INFORMATION (From Photometric File) DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] 11890707.03 [TESTLAB] UL Verification Services Inc. [ISSUEDATE] 8/15/2017 [MANUFAC] Lamar Lighting Co Inc [LUMCAT] SSLED4830-XX [LUMINAIRE]

More information

Lighting Sciences

Lighting Sciences Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY OUTPUT BEAM SIDE LUMENS

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000998-002A Catalog Number: ML5WL-D-HO-ASY-K40-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 720mA. Total Light Output Luminaire Power Luminous Efficacy

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Report No.: GZE150726-B LM-79-08 Test Report For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Four-Foot Linear Replacement Lamps Model name(s): IGTTU-1501850F-4BC

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B/N FLS20U45B/N FLS20U50B/N FLS20U40W/N FLS20U45W/N

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000998-001A Catalog Number: ML3WL-D-HO-ASY-K35-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 600mA. Total Light Output Luminaire Power Luminous Efficacy

More information

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL18297 Performance Summary Emergency Classification Luminous flux 89.6 lm Luminaire Power 1.05 W C0 D10 Luminous Efficacy 85.6 lm/w PREPARED FOR : Atom Lighting Ltd., Arundel, QLD 4214.

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL18299 Performance Summary Emergency Classification Luminous flux 87.6 lm Luminaire Power 1.14 W C0 D10 Luminous Efficacy 76.9 lm/w PREPARED FOR : Atom Lighting Ltd., Arundel, QLD 4214.

More information

Photometric Laboratory Measurement report G001

Photometric Laboratory Measurement report G001 Name and address of customer Chargui Kerkennah 3070 Sfax Result: Light distribution curve [cd] Description of device under test ( DUT ) Art.No.YZDL732B Type of luminaire/lamp Side-entry street luminaire

More information

IP23 15º ±15º 100. This item requires gear. It is not Output (W): 2,2W. included.

IP23 15º ±15º 100. This item requires gear. It is not Output (W): 2,2W. included. DN0511S200 V0 LEO Downlight recessed Description Signal for indoor use. For downlighting. Lenses allow optimum control of illumination with minimal residual halo. Adjustable light source. Structure material:

More information

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) LM-79-08 Test Report For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) 7 F, Jinchangda Industrial Park,zhangkengjing,GuanLan, Baoao,Shenzhen,Guangdong,China 2x2 Luminaires for Ambient Lighting of Interior

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl5s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Dec.05,2016 Review By: Manager: Tommy Liang Note:

More information

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada Four-Foot Linear Replacement Lamps Model name(s): IR-T8-15W4FT16503500K IR-T8-15W4FT16504000K IR-T8-15W4FT16505000K

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B FLS20U45B FLS20U50B FLS20U40W FLS20U45W FLS20U50W

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS40U40B FLS40U45B FLS40U50B FLS40U40W FLS40U45W FLS40U50W

More information

IES INDOOR REPORT PHOTOMETRIC FILENAME : PFXC-CW-0-277E5-35WH-1.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : PFXC-CW-0-277E5-35WH-1.IES. DESCRIPTION INFORMATION (From Photometric File) DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] 3610-2.0 [ECN] 3658 [TESTLAB] Tempo LLC [ISSUEDATE] 10/29/2018 9:53:53 AM [MANUFAC] Tempo LLC [LUMCAT] pfxc-cw-0-277e5-35wh-1 [LUMINAIRE]

More information

M1 INVISIBLE Beacon

M1 INVISIBLE Beacon 55-9-05-M1 INVISIBLE Beacon V0 Designer: Francesc Vilaró Description Bollard for outdoor use. For downlighting. Suitable for installation in marine environments. The optical module can easily be rotated

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl4s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Mar. 01,2017 Review By: Manager: Tommy Liang

More information

Cat# LED High Bay

Cat# LED High Bay Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W

More information

NHÀ THI ĐẤU ĐA NĂNG - ĐẠI HỌC TÂY NGUYÊN

NHÀ THI ĐẤU ĐA NĂNG - ĐẠI HỌC TÂY NGUYÊN THIẾT KẾ CHIẾU SÁNG NHÀ THI ĐẤU ĐA NĂNG SỬ DỤNG ĐÈN LED POTECH Partner for Contact: Mr. KHÔI Order No.: PT-022 Company: TRƯỜNG ĐẠI HỌC TÂY NGUYÊN Customer No.: 005 Date: Operator: BUI CONG CUONG Table

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA55- Catalog Number: X One eldoled SOLOdriver 56/S, 5mA/May x25, LED driver 2.Vac, 6.Hz,.837A, 2.98W,.952PF, 5.44%THD(i) Total Light Output Luminaire Power Luminous Efficacy Performance

More information

GEA Technopolymer Recessed

GEA Technopolymer Recessed 55-9567-Z5-37 V0 GEA Technopolymer Recessed Finish Urban grey Tempered Material Technopolymer Glass IP67 IK08 2 TECHNICAL CHARACTERISTICS Light source Lampholder: x GU Output (W): max. 50W Lamp maximum

More information

Morris Products 53 Carey Road, Queensbury, NY 12804

Morris Products 53 Carey Road, Queensbury, NY 12804 Catalog Number 71622 UPC Number 60198671622 Description LED Ultra Thin Recessed Canopy Fixture 40W Voltage: 120/208/240/277 Shown with optional recessed mounting Bezel/Trim Cat# 71620 QPL ID # P29AE57D

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LLI-14188-20D Performance Summary Total Light Output 310 lm Min Power Factor 0.46 @ 277 V Luminaire Power 9.79 W Max THD(i)* 30.4 % @ 277 V Luminous Efficacy 31.7 lm/w SC along*, across*

More information

LED Entryway Light RoHS

LED Entryway Light RoHS 72508 LED Entryway Light RoHS QPL ID # PSMN8JUU Model: 72508 Input Voltage 120-277 VAC 60HZ Input Current 0.5A Max @120V Input Power 25W Power Factor PF 0.95 OVERALL LAMP PARAMETERS Luminance 3,121 LM

More information

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es) LM-79-08 Test Report For LED Wav es,inc (Brand Name: LED Wav es) 4100 1st Ave,The Esquire Building,Brooklyn, NY 11232 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): SL2-2X2-40W-11

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS 71400A GAS STATION Canopy Luminaire Wet Locations Use QPL ID # PL9D2UU8ZA41 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power

More information

V1 CURL Wall fixture

V1 CURL Wall fixture 0-17-14-14 V1 CURL Wall fixture Description Wall light for indoor use. For uplighting and downlighting. Design by C. Santolaria and lex & Manel Lluscà. Minimalist design. vailable options for regulating

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-22W-ID(X,Clear)

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-13W-ID(X,

More information

LED STREET LIGHT SLIP FITTER MOUNT

LED STREET LIGHT SLIP FITTER MOUNT WARRANTY PART NO: GT-S-G07-CT3A1-BRPAM40 PART NO: GT-S-G07-CT3A1-BRPAM57 DESCRIPTION These lights are the top of the line in quality and price. These fixture are easy to installation and operate and are

More information

Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 (0)

Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 (0) Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 (0) 1727 83 66 11 spheretest@aurora.eu.com www.aurora.eu.com Customer: Product code: Customer: Product code: Test Date: Product 08/12/2015 description:

More information

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 ZOHO Series LED Flood Light Model name(s): BLTFLD50W5K Representative (Tested)

More information

PrevaLED COIN 50 COB G1

PrevaLED COIN 50 COB G1 PrevaLED COIN 50 COB G1 LED modules with integrated optics and heat sink Areas of application _ Retail outlets _ Shop lighting _ Restaurants _ Hospitality _ Museums, galleries Product benefits _ Compact

More information

Number Eight Lighting Company MPT2-HI-R-6-BK/40/DIM1-M-1000

Number Eight Lighting Company MPT2-HI-R-6-BK/40/DIM1-M-1000 Report No: L121706547 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706547 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

Number Eight Lighting Company MPT2-HI-R-6-BK/25/DIM1-M-1400

Number Eight Lighting Company MPT2-HI-R-6-BK/25/DIM1-M-1400 Report No: L121706549 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706549 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

Lab Notes. How to Select the Best Luminaire For Interior Lighting

Lab Notes. How to Select the Best Luminaire For Interior Lighting Lab Notes Issue 12 How to Select the Best Luminaire For Interior Lighting 1.00 Introduction : Lab Note Issue 3 How to Read a Photometric Report, Section 4.3 discusses the various Light Technical Parameters

More information

LED Flat Panel 1X4. Solas Ray Lighting 1524 Jackson Street Anderson, Indiana

LED Flat Panel 1X4. Solas Ray Lighting 1524 Jackson Street Anderson, Indiana LED Flat Panel 1X4 Photometric Filename: FP14-036-40-AC-U-D.IES Photometric Filename: FP14-036-40-AC-U-D.IES Descriptive Information (From Photometric File) IESNA:LM-63-2002 [TEST] 1 [TESTLAB] EVERFINE

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test 13232-2 Performance Summary Total Light Output Luminaire Power Luminous Efficacy 3287 lm 35.6 W 92.3 lm/w PREPARED FOR : Ecolite Manufacturing, 9919 East Montgomery, Spokane, WA 99206. Page

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

Report of Test LLIA R02*

Report of Test LLIA R02* eport of Test LLIA001007-001-02* *This test report supersedes test report LLIA001007-001-01 Catalog Number: F-AL/0/50K/S3 Total Light Output Luminaire Power Luminous Efficacy BUG ating 37571 lm 296.4 W

More information

IES INDOOR REPORT PHOTOMETRIC FILENAME : RDISE24-LED48FRDMV35.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : RDISE24-LED48FRDMV35.IES. DESCRIPTION INFORMATION (From Photometric File) DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] LLIA000653-006 [TESTLAB] LightLab International Allentown, LLC [MANUFAC] Mobern Lighting Co., 8200 Stayton Drive, Jessup, MD 20794,

More information

Standard-Tech Co. Ltd Testing Center

Standard-Tech Co. Ltd Testing Center Test Datasheet Test Location: [ ] 1. B802, No.11 Caipin Road, Guangzhou Science City, Guangzhou, [ ] Guangdong, China 2. R108, 1 st Floor No.69 GuangPu West Road, Guangzhou Science City, Guangzhou, Guangdong,

More information

Mesopic Photometry for SSL. Teresa Goodman Metrology for SSL Meeting 24 th April 2013

Mesopic Photometry for SSL. Teresa Goodman Metrology for SSL Meeting 24 th April 2013 Mesopic Photometry for SSL Teresa Goodman Metrology for SSL Meeting 24 th April 2013 Outline Brief overview of CIE system for mesopic photometry Relevance of mesopic photometry for SSL Is mesopic photometry

More information

Number Eight Lighting Company. 804/J2-WD-25/DIM WD with FS-P-1-WH trim

Number Eight Lighting Company. 804/J2-WD-25/DIM WD with FS-P-1-WH trim Report No: L121706467 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706467 Issue Date: 1/16/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount.   EPA Rating 2. Cat# 71893 380W LED FlatPanel Slipfitter Mount OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output

More information

CERTIFIED TEST REPORT No

CERTIFIED TEST REPORT No Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY ANGLE MEAN CP LUMENS

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For MaxLite Inc 10 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x146,

More information

Adaptive architectural lighting systems IES Report

Adaptive architectural lighting systems IES Report Adaptive architectural lighting systems IES Report BoxRail 107 107-BX-X-4-48-X-X-X-X-X-X-Z-HO-35-S2-X-BL-X The performance data in black text is confirmed through third party testing (see the following

More information

Liedaga iela, Tūja. Partner for Contact: Order No.: Company: Customer No.: Date: Operator: Ilona Kozare

Liedaga iela, Tūja. Partner for Contact: Order No.: Company: Customer No.: Date: Operator: Ilona Kozare Partner for Contact: Order No.: Company: Customer No.: Date: Operator: Ilona Kozare Table of contents Project Cover 1 Table of contents 2 Luminaire parts list 3 VIZULO MINIMARTIN 45W MRS 045 730 L22 A024

More information

V0 AFRODITA Tecto

V0 AFRODITA Tecto 159563437 V AFRODITA Tecto Descrição Tecto de uso exterior para iluminar para baixo. Fonte de luz orientável. Material estrutura: Alumínio extrudido. Acabamento estrutura: Cinza. Material difusor: Vidro.

More information

Lighting fundamentals

Lighting fundamentals Lighting fundamentals About light and photometrics Generation of light Human vision Black body Colour Basic principles of lighting Light sources Light Vision Colour What is light? Light is electromagnetic

More information

Muzeja iela, Ainaži. Partner for Contact: Order No.: Company: Customer No.: Date: Operator: Ilona Kozare

Muzeja iela, Ainaži. Partner for Contact: Order No.: Company: Customer No.: Date: Operator: Ilona Kozare Partner for Contact: Order No.: Company: Customer No.: Date: Operator: Ilona Kozare Table of contents Muzeja iela, Ainaži Project Cover 1 Table of contents 2 Luminaire parts list 3 VIZULO STORK 46 W ME

More information

Report of Test LLIA

Report of Test LLIA eport of Test LLIA001007-002 Catalog Number: F-AL/150/50K/S3 Total Light Output Luminaire Power Luminous Efficacy BUG ating 18778 lm 145.4 W 129.1 lm/w B3-U2-G3 Performance Summary Power Factor THD(i)

More information

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013 industry hall Customer : Processed by : Siteco Light Consulting Project description: spatial geometry (L*W*H): 54,00m*21,00m*9m reflection values (C*W*F): 70*50*20 maintenance factor: 0,67 user surface

More information

PrevaLED COIN 50 DC COB G1

PrevaLED COIN 50 DC COB G1 PrevaLED COIN 50 DC COB G1 LED modules with integrated optics and heat sink Areas of application _ Retail outlets _ Shop lighting _ Restaurants _ Hospitality _ Museums, galleries Product benefits _ Compact

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272,

More information

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T March 26, 2012 Title: TEMPO 21 Report Prepared for: Sviazinvest, OJSC Prepared by: Cree Durham Technology Center (DTC) Ticket Number: 10806-T Co NVLAP lab code 500070-0 The accreditation of the Cree Durham

More information

The Control of Glare by the AS1680 Systems

The Control of Glare by the AS1680 Systems Lab Notes Issue The Control of Glare by the AS1680 Systems 8 1.00 Introduction : This Lab Note is one of several which discusses the matter of glare in the workplace. They have been issued as a series

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For DONGBU LIGHTEC CO. LTD 14, Saneop-ro 104beon-gil, Ojeong-gu, Bucheon-si, Gyeongg-do, Korea

More information

The official directions are written in Chinese, this English edition is for your reference only -1-

The official directions are written in Chinese, this English edition is for your reference only -1- Refer to: R128 00-S2 74.1 Effective Date and Scope: 74.1.1 Effective date from 2017/1/1, the new types of LED replaceable light sources and from 2019/1/1 the all types of LED replaceable light sources

More information

LED Volumetric Luminaires

LED Volumetric Luminaires LED Volumetric Luminaires Limitless Options for the following applications: When appearance is most important, TCP s LED Volumetric Luminaires turn any location into something truly exceptional. The precision-formed

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L06124406 Date: 7/11/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L06124406 MLFP22E4535 Report Prepared For: MAXLITE

More information

Project 1. Partner for Contact: Order No.: Company: Customer No.: Date: Operator:

Project 1. Partner for Contact: Order No.: Company: Customer No.: Date: Operator: Partner for Contact: Order No.: Company: Customer No.: Date: : / Luminaire parts list 20 Pieces LOSON LIGHT 1000W-25D Article No.: Luminous flux (Luminaire): 126857 lm Luminous flux (Lamps): 126861 lm

More information

OFFICE: open plan office

OFFICE: open plan office OFFICE: open plan office Customer : Processed by : Light Consulting (GI S PJS LC) Project description: spatial geometry (L*W*H):,15m*13,5m*,m reflection values (C*W*F): 7*5* maintenance factor:, user surface

More information

SOCCER FIELDS LEVELS FOR UEFA COMPETITIONS ELITE LEVEL A LEVELS : A-B-C-D

SOCCER FIELDS LEVELS FOR UEFA COMPETITIONS ELITE LEVEL A LEVELS : A-B-C-D SOCCER FIELDS LEVELS FOR UEFA COMPETITIONS ELITE LEVEL A LEVELS : A-B-C-D SPORT-LED SPECIAL LIGHTING EQUIPMENT Soccer Field for UEFA competitions Example Soccer Fields UNIFORMITY > 0.90 from > 800 lux

More information

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50 IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp. 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: HBUF-150W-50 Report Type: Test Engineer: Electrical and Photometric tests

More information

Powerful, ultra-slim circular lamps

Powerful, ultra-slim circular lamps Powerful, ultra-slim circular lamps T5 Circular Philips T5 Circular lamps are ultra-slim with improved color rendering, higher efficacy, and longer life.t5 HO circular lamps offer extraordinary light output.

More information

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50 IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: HBUF-100W-50 Report Type: Test Engineer: Electrical and Photometric tests

More information