1 March 26, 2012 Title: TEMPO 21 Report Prepared for: Sviazinvest, OJSC Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

2 Co NVLAP lab code The accreditation of the Cree Durham Technology Center by NVLAP (NVLAP lab code ) to satisfy the requirements of ISO/IEC 17025:2005 and IES LM is presently in progress. This report contains data sets that are not covered by NVLAP accreditation. The measurement data sets contained in this report are related only to the items tested. This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government. This report was generated for: Sviazinvest, OJSC This report was generated by: The Cree Durham Technology Center 4600 Silicon Dr Durham, NC of 41

3 TEMPO 21 Checklist Thermal Solder Point Temperature Measurement Thermal Imaging With IR Camera Electrical Driver Efficiency Transient Analysis Power Analysis (PF, THD) n/a Dimmer Compatibility Test Dielectric Breakdown (Hi-pot) Vf/Current Balancing (Parallel Arrays Only) Mechanical Qualitative Construction Analysis Chemical compatibility Analysis X-ray of Printed Circuit Board Photometric and Optical Luminous Flux Radiant Flux Chromaticity (CRI, CCT, x-y, u -v, duv) Spectral Power Distribution (Visible Range) Illuminance (ft-cd or lux) Luminaire Efficacy (lm/w) Optical Efficiency Component Binning and Color Point Evaluation n/a Review Against ENERGY STAR criteria TM-21 Lifetime estimate 3 of 41

4 EXECUTIVE SUMMARY The Sviazinvest Street Light Model DKU 01-45x uses 45 Xlamp XM-L LEDs. The luminaire produces lumens with a 5226K CCT while consuming 193.7W of power. With an optical efficiency of nearly 90% the luminaire delivers 81 lm/w. Cree Services' TEMPO21 Evaluation process is a thorough multi-point evaluation and analysis of a customer s lighting product. Cree Application Engineering personnel perform a battery of thermal, electrical, mechanical and photometric tests and provide a comprehensive report that includes all relevant data to necessary to confirm the performance of the product. In addition to this standard set of tests, products will also be reviewed against appropriate ENERGY STAR criteria, TM-21 LED Lifetime estimates, and LM-79 conformant tests where applicable. Table 1 below provides a quick summary of the test data. Additional detailed test results are covered in the following pages. Criteria Result Total Luminous Flux (lm) Power (W) Tsp and Tj ( C)¹ 64.3 / 74 Power Factor Lumens per Watt (LPW) 81 Optical Efficiency (%) 90 Driver Efficiency (%) 88 CCT (K) 5226 CRI (Ra) 81 Chromaticity (x-coord) Chromaticity (y-coord) LED Lumen Maintenance² Projected L₇₀(6K) : 362,000 Reported L₇₀(6K) : 36,300 ENERGY STAR Not Applicable Table 1: Summary of Test Results ¹ Measured at ambient temperature of 21.5ºC. ² Per IES TM of 41

5 Incoming Inspection All samples are subjected to a visual, physical inspection to ensure that the product was not damaged during shipping. Two samples were received and were packaged in individual cardboard boxes as shown in Figures 1and 2. No physical damage or other problems were observed. The samples were powered on and appeared to be operating normally as shown in Figure 3. As received pictures Figure 1: As-Received Picture #1 5 of 41

6 Figure 2: As-Received Picture #2 Figure 3: As-Received Picture #3 6 of 41

7 Photometric Testing Photometric testing includes measurements of luminous flux, radiant flux, chromaticity, correlated color temperature (CCT) and color rendering index (CRI). Luminaire evaluation was performed at Cree s photometric testing lab in Durham, NC. A 2-meter Labsphere integrating sphere Model CSLMS-7660 using the 4 geometry method and spectrometer MC-9801:3683 is used to conduct the test. Testing is performed per Cree standard photometric testing protocols, which follow IES LM-79-08¹ and includes procedures such as: absorption correction using a NIST traceable lamp and ensuring the emission plane of the device under test is co-linear with the sphere s sensor baffle. The sample is powered using a Chroma AC Power Source and a Xitron 2801 Power Analyzer is used to measure power. Figure 4: Sample in 2m Integrating Sphere ³ IES LM-79-08, Electrical and Photometric Measurements of Solid State Lighting Products 7 of 41

8 Tests Date Ambient Temp. ( C) Input Voltage (Volts AC) Frequency (Hz) Luminous Flux, Radiant Flux, Chromaticity, Color Rendering, Spectral Power Distribution, Luminaire Efficacy 01-Mar Table 2: Photometric Test Conditions 8 of 41

9 Luminous Flux, Radiant Flux Radiant flux is a measure of the total power of electromagnetic radiation emitted from the luminaire or lamp, while luminous flux is a measurement that is weighted based on human visual perception and measured results are presented in Table 3. Measurements are recorded once per minute over a sufficient period of time to allow the sample to reach thermal equilibrium. In the case of this luminaire, it took approximately 1.5 hours to stabilize as shown in Chart 1. Parameter Stable Data Radiant Flux (Watts) Photopic luminous flux (lumens) Table 3: Luminaire Radiometric and Photometric Output Chart 1: Luminous Flux Plotted Versus Time 9 of 41

10 Luminaire Chromaticity and Color Rendering Parameter Stable Data x coordinate y coordinate u' coordinate v' coordinate Correlated Color Temperature 5226 Delta uv Table 4: Measured Chromaticity and Correlated Color Temperature (CCT) Data Chart 2: Plot of x-y Coordinates on ANSI C78.377A Diagram 10 of 41

11 Chart 3: Correlated Color Temperature vs. Time Color Rendering Index (CRI) Value Average (RA) 81 CRI (R1) 79 CRI (R2) 88 CRI (R3) 91 CRI (R4) 78 CRI (R5) 79 CRI (R6) 81 CRI (R7) 87 CRI (R8) 67 CRI (R9) 6 CRI (R10) 68 CRI (R11) 75 CRI (R12) 55 CRI (R13) 82 CRI (R14) 95 Table 5: Measured Color Rendering Index 11 of 41

12 Luminaire Spectral Distribution Parameter Stable Data Peak Wavelength (nm) 456 Dominant Wavelength (nm) 565 Table 6: Peak and Dominant Wavelength Chart 4: Measured Spectral Power Distribution 12 of 41

13 nm mw/nm nm mw/nm nm mw/nm nm mw/nm Overall Luminaire Efficacy Table 7: SPD Numerical Data The overall luminaire efficacy, also referred to as wall plug efficiency, is a metric of how well the luminaire or lamp converts electrical energy into photons. The input power was measured at an input voltage of 230VAC. Efficacy (At steady state) = Lumens / Total input Power = /193.7 = 81 lm/w 13 of 41

14 Component Binning and Color Point Evaluation A total of 10 LEDs were measured at the binning current of 700 ma. Based on the measured data, the lamps are from the T5 (260 lm min. +/-7%) flux bin and 3B chromaticity bin. Chart 5: Measured Data Plotted on Cree Binning Chart Board/Lamp CCx CCy Lum Flux Table 8: Measured Component Data 14 of 41

15 Illuminance The sample was measured on a type C goniophotometer as shown in Figure 5 and illuminance measurements were calculated from the IES-63 electronic file using Photometrics Pro software. The results of the calculations are shown in Charts 6 and 7. Figure 5: Sample Mounted on Type C Goniophotometer Chart 6: Cone of Light Diagram 15 of 41

16 Chart 7: Isofootcandle Plot 16 of 41

17 Optical Efficiency Calculation The optical system for this luminaire consists of a glass cover and two different types of individual lens that fits over each LED as shown in Figure 6. The sample was tested with and without optics and the results are shown below in Table 9. Using this data, the optical efficiency can be calculated. The initial lumen values were used to avoid any effects due to thermal differences with the optics removed. Figure 6: Optical Components Condition Radiant Flux (Watts) Luminous Flux (lumens) % Loss (overall) With Optics % Glass Removed % No Optics Table 9: Measured Optical Efficiency Optical Efficiency = lumens with optic / lumens without = 16756/18599 = 90.1% 17 of 41

18 Electrical Testing Driver Efficiency Driver efficiency is calculated by dividing the electrical output power supplied to the LEDs by the total input power to the luminaire or lamp. The output power to the LEDs is the sum of the product of the forward voltage and current for each LED. The input power was measured at an input voltage of 230VAC. Driver Efficiency = LED power / Total input power Driver Efficiency = (Vf*If) / Pin Driver Efficiency =(26.7 * ) / Driver Efficiency =87.9 % Power Factor and Harmonic Distortion Power factor is an important metric for LED driver performance, and in the case of street lighting, utility companies may require that luminaires have power factor greater than some specified value. In general the closer the value is to 1, the better the performance. For this luminaire, the power factor is Total harmonic distortion (THD) is defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency. Harmonic currents are a concern because they can produce problems such as noise interference and overheating of electrical distribution system wiring. The total current harmonic distortion (athd) was measured to be less than 10%. Figure 7: Picture of LED driver 18 of 41

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08392-001B S-DL8-A-42L-27K-M w_s-dl8t-a-ss-c Date: 06/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL06803-001A BPAR30S-0803040C-12DE26-1C100 Date: 9/26/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL06982-001A BPAR30L-0803025C-12DE26-1C100 Date: 10/6/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL04091-001 BXSPCxx4MEE30K-xxxxxx or XSPCxx4MEE30Kxxxxxx Date: 8/5/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04150-001 BXSPCxx3MEE40K-xxxxxx or Date: 8/8/2014 XSPCxx3MEE40K-xxxxxx Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code - Report Number: Model: PL-A HXB-A-UV-L-M-K-UL-xx-xxxx Date: // Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08391-001A S-DL8-A-34L-27K-M w_s-dl8t-a-ss-c Date: 05/26/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08381-001A S-DL4-A-42L-35K-M w_s-dl4t-a-ss-c Date: 05/24/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08388-001A S-DL6-A-42L-27K-M w_s-dl6t-a-ss-c Date: 05/19/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08597-001A ZR24M-40L-35K-10V-FD Date: 6/21/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08073-001A S-DL6-63L-27K w_s-dl6t-w-ss-c Date: 05/09/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09635-001A LS8-100L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09633-001A LS4-50L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL07190-001A FP22-34L-40K-10V Date: 12/18/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04023-001 CXBAxxM40K8 CXBA16N Date: 7/27/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers Cree,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08254-001A S-DL4-A-42L-40K-W w_s-dl4t-a-ssc Date: 04/27/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08049-001A S-DL6-15L-27K w_s-dl6t-w-ss-c Date: 04/13/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10277-002B RUL-HT-2ME-C-30K-12-UF-N Date: 02/27/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08050-001A S-DL4-15L-40K w_s-dl4t-m-ss-c Date: 05/1/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL87-1A S-DL8-5L-27K w_s-dl8t-w-ss-c Date: 5/9/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08048-001A S-DL4-15L-27K w_s-dl4t-w-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08047-001A S-DL6-11L-40K w_s-dl6t-m-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08044-001A S-DL4-11L-27K w_s-dl4t-w-ss-c Date: 04/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08078-001B S-DL8-75L-27K w_s-dl8t-w-ss-c Date: 05/10/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08058-001B S-DL4-34L-40K w_s-dl4t-m-ss-c Date: 05/3/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09259-001A OSQ-HO-A-xx-15D-40L-40K-UL Date: 09/26/16 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Chris Strom Cree,

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0013 E-WP6L03CZ Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL843-1A S-CT-MFB-5L-36D-3K-xx Date: 5/26/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tammy

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03402-001 BXOSQAxx4MES40K Date: 04/15/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Brandon Bitner Cree,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: CESTL-2013-0154 BXSPRA*2FG-U** Date: 6/19/2013 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tim Henning Cree, Inc 4600

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09234-001A ZR24M-50L-40K-10V-FD Date: 9/8/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10710-001A OSQ-HO-A-xx-5SH-50L-50K-UL Date: 05/31/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Gerry Thornton

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09255-002A OSQ-HO-A-xx-3ME-40L-40K-UL w/osq-ho-blsf Date: 09/09/16 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL11180-001A OSQ-HO-A-NM-3ME-65L-40K-UL-BZ Date: 08/10/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08473-001A SA21-16027MDFD-12DE26-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09245-001A SPAR38-1503025TD-12DE26-1 Date: 9/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0031 BXSPWA02MC-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0032 BXSPWA03MG-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09300-001A ARE-EHO-3M-xx-12-E-UL-xx-1000-xxxx Date: 09/16/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09299-001A ARE-EHO-AF-xx-12-E-UL-xx-1000-xxxx-40K Date: 09/15/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03375-001 CPY250-A-xx-D-C-UL-xx-40K or Date: 03/24/2014 BXCCAxD04-UW7 or XCCAxD04-UW7 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09294-001A ARE-EDG-3M-xx-06-E-UL-xx-700-xxxx Date: 09/14/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09285-001 ARE-EDG-5M-xx-06-E-UL-xx-700-xxxx-40K Date: 09/13/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

TEMPO 24 Report. Howard Lighting Products. Cree Durham Technology Center (DTC) T. Title: Prepared for: Prepared by: Ticket Number:

TEMPO 24 Report. Howard Lighting Products. Cree Durham Technology Center (DTC) T. Title: Prepared for: Prepared by: Ticket Number: September 29, 2014 Revised October 13, 2014 (Rev 1) Title: TEMPO 24 Report Prepared for: Howard Lighting Products Prepared by: Cree Durham Technology Center (DTC) Contents TEMPO 24 Checklist... 4 Executive

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: RESTL-2013-0012 E-HL6S11CSZ Date: 11/08/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Joshua Krohn Cree,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: Product ID: CESTL-2013-0019 STR-LWY-5M-HT-06-E-UL-XX-700-40K-XXX or BXSL0506E-UD7 PL01041-001 Date: 2/05/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08367-001A SB13-02427MDCH-12GE12-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08368-001A SB13-03427MDCH-12GE12-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: Product ID: CESTL-2013-0028 STR-LWY-4M-HT-06-E-UL-XX-700-40K-XXX or BXSL0406E-UD7 PL01059-001 Date: 2/06/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: Product ID: CESTL-2013-0025 STR-LWY-2M-HT-06-E-UL-XX-700-40K-XXX or BXSL0206E-UD7 PL01056-001 Date: 2/06/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl4s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Mar. 01,2017 Review By: Manager: Tommy Liang

More information

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06410-001A CPY250-A-xx-D-D-UL-40K-xxxx or BXCCAxD17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07860-001B BXSPR-HO-xx-5SH-60W-40K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04395-001 BXSPRBxx3MEA30K-xxxxxx or XSPRBxx3MEA30K-xxxxxx Date: 9/09/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10604-001A CPY250-B-xx-F-A-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06411-001A CPY250-A-xx-F-D-UL-40K-xxxx or BXCCAxA17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl5s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Dec.05,2016 Review By: Manager: Tommy Liang Note:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07611-001A BXSPR-HO-HT-3ME-60W-57K-UL Date: 04/08/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07609-001B BXSPR-HO-HT-3ME-60W-30K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05401-001 RULHT2MEC40K-12xxx Date: 02/11/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Bernard Krauska

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05591-001B CPY250AxxFB-UL40Kxxxx / BXCCAxA13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Checked X.CAO

Checked X.CAO REPORT NUMBER: RAB02141 PAGE: 1 OF 7 CATALOG NUMBER: PIP30/D10 LUMINAIRE: ONE-PIECE CAST METAL HOUSING WITH PAINTED BRONZE FINISH, LED AND DRIVER COMPARTMENT SEPARATED BY FINNED HEAT SINK, ONE WHITE CIRCUIT

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10023-003B ARE-EDG-2MB-xx-06-E-UL-xx-525-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2.02.05 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 12 foot mounting height..01.005.002 REPORT NUMBER: RAB02670 ISSUE DATE: 11/08/16 PAGE: 1 OF 9 DATE SAMPLE TESTED: 11/08/16 CATALOG

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08270-001A BXSPR-HO-HT-3ME-60W-57K-UL w/ XA-SPR3BLS Date: 05/07/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Checked X.CAO

Checked X.CAO REPORT NUMBER: RAB02143 PAGE: 1 OF 7 CATALOG NUMBER: PIP15/D10 LUMINAIRE: ONE-PIECE CAST METAL HOUSING WITH PAINTED BRONZE FINISH, LED AND DRIVER COMPARTMENT SEPARATED BY FINNED HEAT SINK, ONE WHITE CIRCUIT

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10609-001A CPY250-B-xx-F-F-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2.2.5 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 10 foot mounting height. REPORT NUMBER: RAB00701 ISSUE DATE: 02/04/15 PAGE: 1 OF 8 CATALOG NUMBER: VXLED26NDG / VXBRLED26NDG LUMINAIRE:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05642-001B CPY250AxxDB-UL40Kxxxx / BXCCAxD13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0008 E-GL4S03C2K Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10142-001B FLD-EDG-SN-xx-06-E-UL-xx-700-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Transverse Distance in Units of Mounting Heights Street Side House Side INDEPENDENT TESTING LABORATORIES, INC. 2 1 0 1.05.1 1.5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 20 foot

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT8N20-A Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 1 5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 8 foot mounting height. 7 3/4 1 3/4 3 1/8.02 0 3 1/2.01.005

More information

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063 Report No.: EED35I000235-1 Page 1 of 12 Customer : Revolution Lighting Technologies Address : 4139 Guardian Street, Simi Valley, CA93063 Description of the submitted sample(s): Sample Name : LED TUBE Model/Type

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6 LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-6 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9 LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-9 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For MaxLite Inc 10 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x146,

More information

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 ZOHO Series LED Flood Light Model name(s): BLTFLD50W5K Representative (Tested)

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER ALA TO ISO/IEC 170:00. REPORT 800 COMMERCENTRE DRIVE, LAKE FOREST, CA 90 Project No. G10171817 Date: August, 01 REPORT NO. 10171817LAX-00 TEST OF ONE GARAUGE LUMINAIRE

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K

More information

LM-79 Report TEST REPORT NO.M037D

LM-79 Report TEST REPORT NO.M037D LM-79 Report TEST REPORT NO.M037D Test Result Summary Luminaire Manufacturer Luminaire Model Number Input Voltage RMS (V) 120.0 Input Current RMS (A) 0.231 Input Power (W) 27.47 Light Output (lm) 3524

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G100896445 Date: September 26, 2012 REPORT NO. 100896445CRT-001 TEST OF ONE LED

More information

Cat# LED High Bay

Cat# LED High Bay Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W

More information

PHONE: (303) FAX: (303) WEBSITE:

PHONE: (303) FAX: (303) WEBSITE: REPORT NUMBER: ITL71484 PAGE: 1 OF 7 CATALOG NUMBER: LFLED5 / LFLED5BR / LFLED5MBR (FLOOD SERIES) LUMINAIRE: CAST METAL HOUSING, CAST METAL CIRCUIT BOARD MOUNTING BASE, ONE CIRCUIT BOARD WITH ONE LED,

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B/N FLS20U45B/N FLS20U50B/N FLS20U40W/N FLS20U45W/N

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2.005.01.02 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 16 foot mounting height..002 REPORT NUMBER: RAB01042 ISSUE DATE: 07/15/15 PAGE: 1 OF 8 DATE SAMPLE TESTED: 07/15/15 CATALOG NUMBER:

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: ) LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight Page 2 of 14 Report No.: 68.184.15.296.01 Test sample... : Type of test object... : LED Downlight LED Downlight Trade mark... : Model and/or type reference... : EF150-26W-840 Rating(s)... : 220-240V~;

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For DONGBU LIGHTEC CO. LTD 14, Saneop-ro 104beon-gil, Ojeong-gu, Bucheon-si, Gyeongg-do, Korea

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B FLS20U45B FLS20U50B FLS20U40W FLS20U45W FLS20U50W

More information

Report No.: HZ p. (Lumens) Stabilization Time CRI (K)

Report No.: HZ p. (Lumens) Stabilization Time CRI (K) Test Summary Sample Tested: ML2LA23LTRBNI827 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 73.6 1737.0 23.61 0.9872 CCT Stabilization Time CRI (K) (Light & Power)

More information

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount.   EPA Rating 2. Cat# 71893 380W LED FlatPanel Slipfitter Mount OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output

More information