Development of an On-the Analyzer (OSA) for Measuring Soil Chemical Properties
|
|
- Aileen Pearson
- 5 years ago
- Views:
Transcription
1 2 th International Conference on Precision Agriculture (Sacramento, California, USA) Development of an On-the the-spot Analyzer (OSA) for Measuring Soil Chemical Properties Proximal Soil Sensing Proximal Soil Sensing (PSS) is a set of technologies developed to measure the physical, chemical and biological properties of soil when placing the sensor in contact with, or at a proximal distance (less than 2 m) to, the soil being characterized Viacheslav I. Adamchuk Nandkishor M. Dhawale Frederic Rene-Laforest Bioresource Engineering McGill University July 22, 204 Advances in Agronomy 3: Sensor Fusion Soil ph Soil Reflectance Soil ECa Topography Lab data Electrochemical Sensors Automated Soil Testing Potentiometry using Ion-Selective Electrodes (ISEs) Ion-Selective Field Effect Transistors (ISFETs) Shank Soil cutters Purdue University (West Lafayette, Indiana) Coring tube Mixing ISFET Electrode Ion activity Soil ph (H + ) Potassium (K + ) Nitrate (NO 3- ) Sodium (Na + ) ~0 g soil core Add 20 ml DI H 2 O Cleaning Water jet Sample collection for calibration
2 Soil/Buffer ph Mapping On-the-Go Soil preparation and analysis unit The University of Sydney (Sydney, Australia) JTI (Uppsala, Sweden) Soil ph Mapping On-the-Go Waived sampling disc Purdue University (West Lafayette, Indiana) Soil ph Distance from the West End, m Veris MSP Veris MSP3 An apparent electrical conductivity mapping unit comprised of 6 coulters that provide two depths of investigation A soil ph mapping unit that includes a soil sampling mechanism with two ion-selective electrodes and a cleaning water supply system Example Soil ph Mapping Antimony Electrode Directed Soil Sampling Soil ph Maps of a Kansas Field Sandy and stony soils Soil ph Antimony Electrodes R 2 = 0.99 SE = 0.23 UNL (Lincoln, Nebraska) 2006 On-the-Go Mapping Conventional ha Grid Sampling Soil ph Glass Electrodes
3 Integrated Direct Soil Measurement Integrated Agitated Soil Measurement UNL (Lincoln, Nebraska) 7. R 2 = 0.93 (0.96 means) RMSE (Precision) = 0.2 ph Reg. SE (Accuracy) = 0.6 ph Motor-Stirrer Measured ph ph Ion-selective Electrodes (ISE) 7. Reference ph Measured soluble potassium, mg/kg 0 pk R 2 = 0.2 (0.62 means) RMSE (Precision) = 0.3 pk Reg. SE (Accuracy) = 0. pk 0 00 Reference soluble potassium (AAS), mg/kg Measured nitrate-nitrogen, mg/kg 00 R 2 = 0.3 (0.6 means) RMSE (Precision) = 0.9 pno3 Reg. SE (Accuracy) = 0.2 pno3 0 pno 3 0 Reference nitrate-nitrogen (CR), mg/kg Agitation Chamber and Stirrer Soil Sampler ASM - Laboratory Test Portable Probe Reference tests: Soil ph - glass ion-selective electrode - RMSE = 0.0 ph Soluble potassium - atomic adsorption spectroscopy (AAS) - RMSE = 0.0 pk - Residual nitrate - cadmium reduction (CR) - RMSE = 0.02 pno 3 Measured ph R2 = 0.98 (0.99 means) RMSE (Precision) = 0.08 ph Reg. SE (Accuracy) = 0.09 ph ph Reference ph 00 0 Measured soluble potassium, mg/kg R 2 = 0.9 (0.98 means) RMSE (Precision) = 0.0 pk Reg. SE (Accuracy) = 0.03 pk 0 pk 0 00 Measured nitrate-nitrogen, mg/kg pno 3 R 2 = 0.48 (0.67 means) RMSE (Precision) = 0.3 pno3 Reg. SE (Accuracy) = 0. pno3 0 Reference soluble potassium (AAS), mg/kg Reference nitrate-nitrogen (CR), mg/kg On-the-Spot Nitrate Sensing Veris ph Detector 3 Rep Immediately Available Nitrate-N, mg/kg Rep 2 Rep 3 Avg R 2 = 0.8 Plot ID 4 Macdonald Farm (McGill) 20 Mineral nitrogen (Lab), mg/kg Nitrate activity (ISE), mg/kg One ph ISE electrode
4 Semi-Automatic Soil Sampling Point Measurements Temporal monitoring Soil profiling On-the-Spot Soil Analysis In situ measurement Predefined depth near soil surface Preconditioned surface Sensor integration Autonomous operation Vehicle versatility Low cost Linear actuators Support frame On-the-Spot Analyzer (OSA) ISEs Water jet nozzles Protecting disc Limit switches Cutting blade Hitch insert Soil preparation mechanism Electric Motor GPS receiver Speed controller DC motor OSA Prototype Custom LabView interface Magnetic reed switches Limit switch Water tank V cable Heavy duty linear motor ISE Relay driver GND cable High speed linear motor Sensor deployment mechanism USB 626 2V car battery Water pump V V OSA Control Two ph, a K, and an NO 3, ion-selective electrodes Potentiometer analog input from linear motors Relay Solenoid valve Soil preparation mechanism Standard hitch System control
5 Preliminary Field Testing OSA Field Operation 8 Soil ph (Laboratory) 7 6 R 2 = Soil ph (Field) MIR Spectroscopy In situ Microscopy Diffuse Reflectance Variable Filter Array Mid-Infrared (MIR) spectroscopy nm or nm OSA Highlights The system was designed in such a way that it can be operated from the standard hitch of a pickup, an allterrain vehicle, or another platform. Measurement locations and density can be either predefined or adjusted in real time to respond to the quality and variability of the measurements already obtained at a given site. The low destruction approach makes this method applicable to specialty and perennial crop environments. E:mail: viacheslav.adamchuk@mcgill.ca
Automated On-the. the-spot Analysis of Physical, Chemical and Biological Soil Properties. Sensor Fusion. Electrochemical Sensors
The 4 th Global Workshop on Proximal Soil Sensing (Hangzhou, China) Automated On-the the-spot Analysis of Physical, Chemical and Biological Soil Properties Viacheslav Adamchuk Bharath Sudarsan Nandkishor
More informationthe-go Soil Sensing Technology
Agricultural Machinery Conference May, 006 On-the the-go Soil Sensing Technology Viacheslav I. Adamchuk iological Systems Engineering University of Nebraska - Lincoln Agenda Family of on-the-go soil sensors
More informationProblem Statement. Case Studies on the Accuracy of Soil ph and Lime Requirement Maps. Automated Soil Testing. Direct Soil Measurement.
The th ECPA (Prague, Czech Republic) July 13, 2011 Case Studies on the Accuracy of Soil and Lime Requirement s Viacheslav I. Adamchuk Bioresource Engineering, McGill University Allison K. Jonjak,, Charlie
More informationthe-go Proximal Soil Sensing for Agriculture
AGRI-SENSING 2011 (Haifa, Israel) On-the the-go Proximal Soil Sensing for Agriculture Viacheslav I. Adamchuk Department of Bioresource Engineering McGill University Problem Statement The assessment of
More informationDevelopment of On-the Soil Sensor Systems
First Global Workshop on High Resolution Digital Soil Sensing and Mapping (Sydney, Australia) February 6, 00 Development of On-the the-go Soil Sensor Systems Viacheslav I. Adamchuk Problem Statement The
More informationUsing Ion-Selective Electrodes to Map Soil Properties
Using Ion-Selective Electrodes to Map Soil Properties Viacheslav Adamchuk Biological Systems Engineering University of Nebraska - Lincoln AETC Conference February 1, 3 Outline Conventional methods of soil
More informationQuantifying the Value of Precise Soil Mapping
Quantifying the Value of Precise Soil Mapping White Paper Contents: Summary Points Introduction Field Scanning Cost/Benefit Analysis Conclusions References Summary Points: Research shows that soil properties
More informationVacuum Kelvin Force Probe Research Richard Williams August 1st 2008
Vacuum Kelvin Force Probe Research Richard Williams August 1st 2008 Introduction Kelvin Force Probe Microscopy is an analytical method to measure the contact potential difference between a reference material
More informationINTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY
INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK SOIL NITROGEN DETECTION USING NEAR INFRARED SPECTROSCOPY SNEHA J. BANSOD Department
More informationwater proof water proof Tap water, pure water application Precious, trace amount sample 3-in-1 Plastic Electrode D
ELECTRODE LINE UP electrode just got Touer! Enhanced durability of the glass membrane makes it four times stronger than the conventional Tou electrode. Response glass NEW The patented silver ion trap technology
More informationVisible-near infrared spectroscopy to assess soil contaminated with cobalt
Available online at www.sciencedirect.com Procedia Engineering 35 (2012 ) 245 253 International Meeting of Electrical Engineering Research ENIINVIE 2012 Visible-near infrared spectroscopy to assess soil
More informationMICROFLUIDIC ANALYSER FOR ph IN WATER AND WASTEWATER
Proceedings of the 13 th International Conference on Environmental Science and Technology Athens, Greece, 5-7 September 2013 MICROFLUIDIC ANALYSER FOR ph IN WATER AND WASTEWATER J. CLEARY, D. COGAN, T.
More informationBackground. Analysis of Sensor Array for Measuring Soil Resistance Forces. Field Test. Previous Design. Objectives
Analysis of Sensor Array for Measuring Soil Resistance Forces Viacheslav Adamchuk Mark Morgan Hartono Sumali Agricultural and Biological Engineering Purdue University Setemer 999 Background Soil comaction
More informationWATER QUALITY ANALYZERS SENSOR TECHNOLOGY. Customer Registration System. Dimesional Outlines Unit: mm(in) ORP ION. Conductivity.
Dimesional Outlines Unit: mm(in) F-50 Series / DS-50 Series 374(14.7) D-50 Series / ES-51 / OM-51 179(7.0) 80(3.1) 40(1.6) 230(9.1) 339(13.3) 170(6.7) CE marking compliant 68(2.7) 30 (1.2) Customer Registration
More informationPetrochemical. Transformer Oil Gas Analysis - TOGA
Petrochemical Transformer Oil Gas Analysis - TOGA www.dps-instruments.com The DPS TOGA GC Systems are designed to analyze oil from electrical insulation materials that may have decomposed under thermal,
More informationPOTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA. Background
POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA Background In this experiment, students will familiarize themselves with potentiometric titration, practice using the first derivative to find the equivalence
More informationTitration of a strong acid with a strong base with Cobra4
Titration of a strong acid with a strong base with Cobra4 TEC Related topics Strong and weak acids and bases, ph value, titration curves, equivalence point, potentiometry. Principle Hydrochloric acid is
More informationAutomatic titrators, TitroMatic
112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator
More informationSimplified Analysis for Soil Samples with Compact Water Quality Meter <LAQUAtwin>
Feature Article Simplified Analysis for Soil Samples with Compact Water Quality Meter Measurement of exchangeable calcium ion and potassium ion in soil Keiko KUWAMOTO Exchangeable calcium ion
More informationExercise 2-4. Titration of a Buffer Solution EXERCISE OBJECTIVES
Exercise 2-4 Titration of a Buffer Solution EXERCISE OBJECTIVES To define the terms buffer solution and buffer capacity; To titrate a buffer solution with a weak acid solution; To plot a graph using the
More informationF- Cl- Br- I- CN- S2- NO3-
Middle of the 60 s First ISE for fluoride Na+ K+ Ag+ Ca2+ NH + 4 Cu2+ Pb2+ F- Cl- Br- I- CN- S2- NO3- Environment Food industry and agriculture Medecine, pharmaceutical, cosmetics Power plants Fluoride
More informationREVIEW OF OPTOELECTRONIC DETECTION METHODS FOR THE ANALYSIS OF SOIL NUTRIENTS Akshay Sankpal 1, Krishna K. Warhade 2 1
REVIEW OF OPTOELECTRONIC DETECTION METHODS FOR THE ANALYSIS OF SOIL NUTRIENTS Akshay Sankpal 1, Krishna K. Warhade 2 1 M.E. student at Department of Electronics & Telecommunication, MITCOE, Pune, India
More informationNitrate and ph sensors for deployment in a global ocean observing array: simple sensors that operate for years without recalibration
Nitrate and ph sensors for deployment in a global ocean observing array: simple sensors that operate for years without recalibration Ken Johnson Monterey Bay Aquarium Research Institute Moss Landing, CA
More informationGuide to ph Analysis.
Guide to ph Analysis. XX Why Contents ph Matters Table of Contents Why ph Matters pg 4 What You Need pg 6 How to Measure pg 14 Slope and offset pg 18 Checklist pg 20 Best Practices pg 21 2 Guide to ph
More informationAnion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM
IC Application Work AW CH6-1048-012011 Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM Branch: Chemical industry; Water, wastewater, environmental protection,
More informationBuffer Preparation. Learning Objectives:
Proteomics Buffer Preparation Buffer Preparation Maintaining the optimum ph during the biological sample processing is to maintain the proper functional and structural aspects of the sample. It is important
More informationSupporting Information for: Potentiometric Sensing Array for Monitoring Aquatic Systems
Electronic Supplementary Material (ESI) for Environmental Science: Processes & Impacts. This journal is The Royal Society of Chemistry 2015 Supporting Information for: Potentiometric Sensing Array for
More information1225 Lab # 11 Fluoride Speciation and Analysis by Flow Injection using Ion-Selective Electrode: Measurement of Total Fluoride in Water
1225 Lab # 11 Fluoride Speciation and Analysis by Flow Injection using Ion-Selective Electrode: Measurement of Total Fluoride in Water Introduction Fluoride is recognized world- wide to help build stronger
More informationMultimodal probe based on ISFET electrochemical microsensors for in-situ monitoring of soil nutrients in agriculture
Multimodal probe based on ISFET electrochemical microsensors for in-situ monitoring of soil nutrients in agriculture Matthieu Joly, Laurent Mazenq, Maurane Marlet, Pierre Temple-Boyer, Céline Durieu, Jérôme
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationOur Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.
The Drop Counter sensor is an optical sensor that accurately records the number of drops of titrant added during a titration. The Drop Counter sensor software can automatically convert the number of drops
More informationPRECISION AGRICULTURE APPLICATIONS OF AN ON-THE-GO SOIL REFLECTANCE SENSOR ABSTRACT
PRECISION AGRICULTURE APPLICATIONS OF AN ON-THE-GO SOIL REFLECTANCE SENSOR C.D. Christy, P. Drummond, E. Lund Veris Technologies Salina, Kansas ABSTRACT This work demonstrates the utility of an on-the-go
More informationApplication Bulletin
No. 292e Application Bulletin Of interest to: Plating industry, semiconductor industry, automotive industry, aeronautic industry, electroless nickel plating, hypophosphite, alkalinity P 9, 10 Determination
More informationVacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular
Vacuum Technology Vacuum Pumps Two general classes exist: Gas transfer physical removal of matter Mechanical, diffusion, turbomolecular Adsorption entrapment of matter Cryo, sublimation, ion Mechanical
More informationChallenges of Transport Phenomena in Research and Education. Miniaturized and Integrated Sensors and Microsystems
Challenges of Transport Phenomena in Research and Education Miniaturized and Integrated Sensors and Microsystems Jane P. Chang Chemical and Biomolecular Engineering Department University of California,
More informationMagnetic Property Measurement System
Magnetic Property Measurement System Product Description Quantum Design's MPMS 3 represents the culmination of more than 3 years of development and design in the world of SQUID Magnetometry. Providing
More informationLCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) ,
LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) 777-5232, info@labconserv.com www.labconserv.com What is Acidity and Alkalinity? What does ph mean? How do we measure ph? How
More informationICP-OES Application Note Number 35
ICP-OES Application Note Number 35 Rapid measurement of major, minor and trace levels in soils using the Varian 730-ES Vincent Calderon Varian, Inc. Introduction As part of the global strategy for sustainable
More informationDATA COLLECTION AND ANALYSIS METHODS FOR DATA FROM FIELD EXPERIMENTS
DATA COLLECTION AND ANALYSIS METHODS FOR DATA FROM FIELD EXPERIMENTS S. Shibusawa and C. Haché Faculty of Agriculture, Tokyo University of Agriculture and Technology, Japan Keywords: Field experiments,
More informationatomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive
Chapter 9: End-of-Chapter Solutions 1. The following comparison provides general trends, but both atomic absorption spectroscopy (AAS) and atomic absorption spectroscopy (AES) will have analyte-specific
More informationThermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant
Thermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant Approved ASTM Method for Fluoride in Drinking Water and Wastewater Analyze free fluoride ions
More informationph Probe ReallyEasyData com
ph Probe 9200001 Uses Whether you re monitoring ph for chemistry, physical science, life science, or earth science activity, this ph meter offers accurate readings in a convenient format. Use the RED ph
More informationThe solution for all of your
The solution for all of your nanoparticle sizing and zeta potential needs. DelsaNano Series Blood Banking Capillary Electrophoresis Cell Analysis Centrifugation Genomics Lab Automation Lab Tools Particle
More informationPYCKO SCIENTIFIC LIMITED
PYCKO SCIENTIFIC LIMITED 31 London Road, Grantham, NG31 6EX Telephone 01476 401992 bill@pycko.co.uk www.pycko.co.uk Your Alternative To The Obvious RayMon10 TM Detect, measure, identify and analyse radionuclides
More informationFig. Electrochemical Cell/ Potentiometric Titration
Fig. Electrochemical Cell/ Potentiometric Titration The accurate, precise and effective potentiometric measurements can be made with the help of the following two types of electrodes namely : REFERENCE
More informationPOTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA
POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA Introduction In this experiment, students will familiarize themselves with potentiometric titration, practice using the first derivative to find the equivalence
More informationJAPAN QUALITY. Automated Clinical Analyzer
JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability
More informationSCANNING-PROBE TECHNIQUES OR APPARATUS; APPLICATIONS OF SCANNING-PROBE TECHNIQUES, e.g. SCANNING PROBE MICROSCOPY [SPM]
G01Q SCANNING-PROBE TECHNIQUES OR APPARATUS; APPLICATIONS OF SCANNING-PROBE TECHNIQUES, e.g. SCANNING PROBE MICROSCOPY [SPM] Scanning probes, i.e. devices having at least a tip of nanometre sized dimensions
More informationDEPARTMENT OF ELECTRONICS AND INSTRUMENTATION ENGINEERING SRM NAGAR, KATTANKULATHUR-603203 EI 2302 ANALYTICAL INSTRUMENTS QUESTION BANK UNIT I COLORIMETRY AND SPECTROPHOTOMETRY Part A 1. State Lambert
More informationMETHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)
METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE) 1.0 SCOPE AND APPLICATION 1.1 This automated method is applicable to ground water, drinking and surface waters, and domestic and industrial wastes
More informationSCIENCE WITH DIRECTED AERIAL DR. ALEXEY PANKINE GLOBAL AEROSPACE CORPORATION SAILING THE PLANETS
: SCIENCE WITH DIRECTED AERIAL ROBOT EXPLORERS (DARE) DR. ALEXEY PANKINE GLOBAL AEROSPACE CORPORATION 1 NEW ARCHITECTURE FOR PLANETARY EXPLORATION KEY ELEMENTS: Long-Duration Planetary Balloon Platforms
More informationDHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual
DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual WD1063 Rev B Revised 02/23/15 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131
More informationELECTROCHEMICAL SENSORS FOR SOIL NUTRIENT DETECTION: OPPORTUNITY AND CHALLENGE
ELECTROCHEMICAL SENSORS FOR SOIL NUTRIENT DETECTION: OPPORTUNITY AND CHALLENGE Jianhan Lin, Maohua Wang *, Miao Zhang, Yane Zhang, Li Chen Key Laboratory of Modern Precision Agriculture System Integration,
More informationUltra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES
Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES Application note Geochemistry, metals, mining Authors John Cauduro Agilent Technologies, Mulgrave, Australia Introduction
More informationIon-Chamber Survey Meter OD-02
Ion-Chamber Survey Meter OD-02 Dose and dose rate meter for measuring the ambient dose equivalent H*(10) and dose rate equivalent dh*(10)/dt as well as the directional dose equivalent H (0,07) and dose
More informationJAPAN QUALITY. Automated Clinical Analyzer
JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More information110 Lowell Rd Hudson, NH USA Tel:
110 Lowell Rd Hudson, NH 03051 USA Tel: 603-886-8400 www.teledyneleemanlabs.com Product Descriptions and Offerings Teledyne Leeman Labs is a leading innovator of analytical instrumentation for elemental
More informationSAILING THE PLANETS: PLANETARY EXPLORATION FROM GUIDED BALLOONS. 7 th Annual Meeting of the NASA Institute for Advanced Concepts
SAILING THE PLANETS: PLANETARY EXPLORATION FROM GUIDED BALLOONS 7 th Annual Meeting of the NASA Institute for Advanced Concepts DR. ALEXEY PANKINE GLOBAL AEROSPACE CORPORATION SAILING THE PLANETS 1 MARS
More informationDevelopment of Ion-Selective Electrode Fabrication Process Based-on Drop-On- Demand Printing Technique
Development of Ion-Selective Electrode Fabrication Process Based-on Drop-On- Demand Printing Technique Juthapan Wannasai, Kunchorn Sarawong and Mana Saedan* Automation and Applied Modeling Laboratory Department
More informationRAPID AND LOW-COST DETERMINATION OF HEAVY METALS IN SOIL USING AN X-RAY PORTABLE INSTRUMENT
Scientific Papers, UASVM Bucharest, Series A, Vol. LIV, 2011, ISSN 1222-5339 RAPID AND LOW-COST DETERMINATION OF HEAVY METALS IN SOIL USING AN X-RAY PORTABLE INSTRUMENT MIHAELA ULMANU*, ILDIKO ANGER*,
More informationMobile coulometer for water determination anywhere you want
899 Coulometer Mobile coulometer for water determination anywhere you want Extremely small & compact Maximum flexibility due to independent power supply Automatic start of titration 899 Coulometer the
More informationNanotechnology Sensors
ESILAB PACK : 1 Ion + ph Nanotechnology Sensors email : contact@water-kits.fr This revolutionary technology based on carbon nanotubes hugely simplifies the potentiometric measurements. Measurement & calibration
More informationph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m
s ph electrodes are constructed from a special composition which senses the hydrogen ion concentration. This is typically composed of alkali metal ions. The alkali metal ions of the and the hydrogen ions
More informationMULTICHANNEL NADIR SPECTROMETER FOR THEMATICALLY ORIENTED REMOTE SENSING INVESTIGATIONS
S E S 2 5 Scientific Conference SPACE, ECOLOGY, SAFETY with International Participation 1 13 June 25, Varna, Bulgaria MULTICHANNEL NADIR SPECTROMETER FOR THEMATICALLY ORIENTED REMOTE SENSING INVESTIGATIONS
More informationLow Cost Weather Stations for Developing Countries (Kenya)
Low Cost Weather Stations for Developing Countries (Kenya) Charles Mwangi Kenya Space Agency 7 th UNSPIDER Conference 23th-25th October 2017 Prepared with support of: Martin Steinson/Paul Kucera - UCAR/NCAR
More informationDevelopment of multi-functional measurement devices for vadose zone characterization
Development of multi-functional measurement devices for vadose zone characterization Jan Hopmans University of California, Davis, CA, USA Yasushi Mori Shimane University, Japan Annette Pia Mortensen Geological
More informationWATER QUALITY ANALYZERS SENSOR TECHNOLOGY ORP ION. Conductivity. Temperature. Resistivity SALT
WATER QUALITY ANALYZERS ORP SENSOR TECHNOLOGY Conductivity DO Temperature Resistivity WaterQuality(E)出力用 10.6.24 9:12 PM ページ1 ELECTRODE LINE UP NEW Sleeve 6367-10D Precious, trace amount sample 3-in-1
More informationExp. #2-4 : Measurement of Characteristics of Magnetic Fields by Using Single Coils and a Computer Interface
PAGE 1/17 Exp. #2-4 : Measurement of Characteristics of Magnetic Fields by Using Single Coils and a Computer Interface Student ID Major Name Team No. Experiment Lecturer Student's Mentioned Items Experiment
More informationTex-620-J, Determining Chloride and Sulfate Contents in Soil
Contents in Soil Contents: Section 1 Overview...2 Section 2 Sample Preparation...3 Section 3 Ion Chromatography Method...5 Section 4 Wet Chemical Method...9 Section 5 Archived Versions...15 Texas Department
More informationElectrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about
Electrochemistry LEC 06 What you can learn about Galvanic cell Types of electrodes Nernst equation Potentiometry Principle and tasks The cell voltage and the Galvani voltage of the electrodes of an galvanic
More informationTHE VERSATILE VSP2: A TOOL FOR ADIABATIC THERMAL ANALYSIS AND VENT SIZING APPLICATIONS
THE VERSATILE VSP2: A TOOL FOR ADIABATIC THERMAL ANALYSIS AND VENT SIZING APPLICATIONS Charles F. Askonas, Dr. James P. Burelbach, and Dr. Joseph C. Leung Fauske and Associates, Inc. 16W070 W. 83 rd Street
More informationAssessing Mixing Sensitivities for Scale-up. Matthew Jörgensen Atlanta, 10/20/2014
Assessing Mixing Sensitivities for Scale-up Matthew Jörgensen Atlanta, 10/20/2014 Nalas: Solutions that Scale! Engineering Services Broad range of services & capabilities supporting chemical process development
More informationOdor Detection and Analysis using GC/SAW znose
Complimentary Copy Odor Detection and Analysis using GC/SAW znose Edward J. Staples Electronic Sensor Technology 1077 Business Center Circle Newbury Park, California 91320 Ph. 1-805-480-1994 FAX 1-805-480-1984
More informationION SELECTIVE ELECTRODES FOR SOLUBLE SALT MEASUREMENTS ON ICY WORLDS
ION SELECTIVE ELECTRODES FOR SOLUBLE SALT MEASUREMENTS ON ICY WORLDS A. C. Noell, E. A. Oberlin, A. M. Fisher, R. C. Quinn, A. J. Ricco, R. E. Gold and S. P. Kounaves Jet Propulsion Laboratory, California
More informationSOPHAS - Speeding up the process of discovery and optimisation
SOPHAS Automated System For Any Synthesis Application SOPHAS - Speeding up the process of discovery and optimisation The SOPHAS system is an automatic system for synthesis and sample preparation that comprises
More informationNON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)
Gas Chromatography NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25) The Non-Methane Organic Compounds (NMOC) Analyzer is a gas chromatograph configured for analyzing gaseous samples for total organic
More informationUniversity of Kentucky College of Agriculture Division of Regulatory Services
University of Kentucky College of Agriculture Division of Regulatory Services Comparison of Manual and Automatic Titrametric Analysis of Potassium in Fertilizer using AOACI Method 958.02 C. Wayne Ingram,
More informationCHLORINE THEORY & MEASUREMENT
CHLORINE THEORY & MEASUREMENT Introduction Chlorine, dissolved in liquid, is one of the most effective and economical germ-killers for the treatment of water to make it potable or safe to drink. Chlorine's
More informationApplication Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer
Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer Updated July 2017 Introduction: Alkalinity refers to the acid-neutralizing or buffering capacity of a solution.
More informationProduct Descriptions and Offerings
Product Descriptions and Offerings Teledyne Leeman Labs is a leading innovator of analytical instrumentation for elemental analysis. Laboratories in industries ranging from environmental science, oil and
More informationThe Basic Research for the New Compass System Using Latest MEMS
International Journal on Marine Navigation and Safety of Sea Transportation Volume 4 Number 3 September 21 The Basic Research for the New Compass System Using Latest MEMS G. Fukuda Graduate Student in
More informationMETHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE
METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE 1.0 SCOPE AND APPLICATION 1.1 This method can be used for measuring total solubilized nitrate in drinking
More informationChapter Four. Experimental
Chapter Four 4.1 Materials N,N-Diethyl monoethanolamine (purity 98%) used in all experiments was purchased from Spectrochem Pvt. Ltd., Mumbai. N-Ethyl monoethanolamine, N-(- aminoethyl)ethanolamine, diethanolamine,
More informationEXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00
NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 2008 (12041002) (X-Paper) 09:00 12:00 EXEMPLAR This question paper consists of 7 pages. EXEMPLAR -2- NC(V) TIME: 3 HOURS
More informationWash Water Sanitizers and their Measurement Verification of Validation. Presented by: Karan Khurana Pulse Instruments
Wash Water Sanitizers and their Measurement Verification of Validation Presented by: Karan Khurana Pulse Instruments Irrigation, Pre Cooling & Packing Process Applications Process Stability Specification:
More informationSTANDARD OPERATING PROCEDURE (SOP) FOR ESTIMATION OF DIETARY INTAKE OF SODIUM (DIS) IN 24 HOUR URINE USING ELECTROLYTE ANALYZER
STANDARD OPERATING PROCEDURE (SOP) FOR ESTIMATION OF DIETARY INTAKE OF SODIUM (DIS) IN 24 HOUR URINE USING ELECTROLYTE ANALYZER Estimation of Dietary Intake of Sodium (DIS) in 24h Urine on electrolyte
More information2d-Laser Cantilever Anemometer
2d-Laser Cantilever Anemometer Introduction Measuring principle Calibration Design Comparative measurement Contact: Jaroslaw Puczylowski University of Oldenburg jaroslaw.puczylowski@forwind.de Introduction
More informationI n t h e a i r, o n l a n d,
I n t h e a i r, o n l a n d, a n d u n d e r t h e s e a. W e a r e p a s s i o n a t e a b o u t o u r h y d r a u l i c s. L e t u s s u r p r i s e y o u! During its fifty years of experience in the
More informationthe foundation of any business starts here
the foundation of any business starts here TABLE OF CONTENT The Company... 3 Electric Motors... 4 Gearboxes... 5 Automation Products... 6 Electric Components... 9 Pneumatics... 12 Hydraulics... 13 Handling
More informationExercise 2-2. Titration of a Strong Acid EXERCISE OBJECTIVES
Exercise 2-2 Titration of a Strong Acid EXERCISE OBJECTIVES To describe the effect of a ph variation on a chemical indicator; To titrate water containing a strong base solution with a strong acid solution;
More informationRS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers
RS DYNAMICS ECOPROBE 5 Portable IR/PID Gas Analyzer PID + IR PID and IR Analyzers General ECOPROBE 5 has two autonomous analyzers in one case. The combination of analyzers provides a set of data designed
More informationcalorimeter heat flow calorimetry, power compensation calorimetry
calorimeter heat flow calorimetry, power compensation calorimetry Atlas simply does it all What is the Atlas Reaction Calorimeter? The Atlas Reaction Calorimeter accurately measures the power and enthalpy
More informationThermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations
Thermo Scientific Orion Star T900 Series Laboratory Titrators Potentiometric titrators for performing automated ph, redox, or ion titrations Thermo Scientific Orion Star T900 Series Titrators Automate
More informationLABOTRON EXTRACTION & SYNTHESIS 2450 MHz
LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out
More informationUsing Conductivity to Find an Equivalence Point
Experiment 25 PRE LAB DISCUSSION In this experiment, you will monitor conductivity during the reaction between sulfuric acid, and barium hydroxide in order to determine the equivalence point. From this
More informationAnalysis of cations and anions by Ion- Selective Electrodes (ISEs)
Analysis of cations and anions by Ion- Selective Electrodes (ISEs) Purpose: The purpose of this assignment is to introduce potentiometric measurements of ionic species by ion selective electrodes (ISEs)
More informationDevelopment and proof for monitoring technique of sub-seabed CCS
Development and proof for monitoring technique of sub-seabed CCS Kimonori Shitashima IEAGHG 2 nd Combined Meeting of the Modelling and Monitoring Networks 6-8 July 2016, Edinburgh Detection/monitoring
More informationConcise laboratory catalogue
2008 Concise laboratory catalogue Portable and bench-top instruments for ph, EC, ISE, DO and C measurements. Simple and advanced models covering from routine measurements to maximum requirements in investigation.
More informationLab #6: CARBOXYLIC ACIDS LAB
lab Lab #6: CARBOXYLIC ACIDS LAB Name PART I: Preparation of Carboxylic Acids (a) Oxidation of an Aldehyde by Oxygen from the Air: Benzaldehyde is an aromatic aldehyde with a familiar odor. On a clean,
More information