GT-40/GT-40S Multipurpose Gamma-Ray Spectrometer Ancestors: GS-256 by Geofyzika Brno 1975 GR-256 by Exploranium Canada 1977 GR-320 by Exploranium
|
|
- Rosanna Flynn
- 5 years ago
- Views:
Transcription
1 GT-40/GT-40S Multipurpose Gamma-Ray Spectrometer Ancestors: GS-256 by Geofyzika Brno 1975 GR-256 by Exploranium Canada 1977 GR-320 by Exploranium Canada
2 What is common on the current market Handheld Spectrometer for Gamma-Ray NaI/Tl 3x3 or 2x2 BGO Battery powered Methods for NORM Radionuclides Assay 1024 channels analyser (MCA) 2
3 What is new Single unit with detector and all electronic build in one case Fully digital spectrometer Spectra free of differential nonlinearity 1: Full spectra linearization during conversion; Energy calibration 3 kev / channel Proportional gain compensation on backstage using natural BG spectral pattern Color trans reflective display the more light the better readability Powerful CPU with embedded Linux TCP/IP WLAN GPS build in the unit Voice recorder 3
4 What is unique Math methods for advanced ASSAY evaluation of activities using least square fitting of spectral shape Very high sensitivity and dynamic range and minimal components crosstalk (20 Bq/kg Cs-137 on 400 ppm U) High Accuracy Multiple measurement calibrations - Methods Removable lead collimator GT-40S Easy integration in automated processes (Sample changers, position control etc.) 4
5 Why GT-40 / GT-40S One unit for plenty of application All in one powerful computer and gamma-ray detector Sensitive search Data Recorder with new Browser Worldwide access via internet remote maintenance Easy remote operation Team work with other GT-40S Applications NORM Field Spectroscopy - Man-made contamination - Core logging - Construction Building Materials control - Easy Lab Unit - Remote station - Industry 5
6 NORM in Geo ASSAY of K, U and Th in various geometries (infinite area, intrusions in outcrops, boreholes, caves Combination of K, U, Th assay with surface contamination measurement (Cs-137 or other nuclides in Bq/m 2 Chernobyl, Fukushima) Determination of ratio between U and Ra User adjustable formula for traditional Values and units e.g. eu, eth, K/U.. Applications Exploration - Mineralogy - Petrophysics - Mining - Building industry 6
7 Man-made contamination/environment Targeting of Radioactive Sources Nuclide Identification including Categories and Intensities Activity evaluation in various units (Bq, Ci, volume, mass or area activities) Long term monitoring in predefined tasks for permanent surveillance Applications Cleaning of contaminated areas or technologies - Waste water management - Long term local background monitoring - Waste deposits - Land contamination Screening - Traceing methods 7
8 Core logging Adaptable in variety of shieldings Internal collimator for higher resolution Calibrations for different core diameters K, U, Th response API, Total or Dose Rate Automated depth control for faster measurement Applications - Stratigraphy - Mineralogy - Oil and Gas - Mining 8
9 Construction Building Materials Certification Activity Index, Gamma Index, Radon Index Buildings sanitation Applications Sick Houses monitoring Raw Material Certification Construction Materials Defectoscopy Exploatation strategy 9
10 Lab Applications and Experimental Lab Kit (GT-40 with desktop shielding and calibration set) for High sensitivity measurement Short measuring times Minimal Operation costs (No liquid nitrogen) Up six different Radioelements analyse and activity evaluation in mixtures per method Capable to identify over 150 gamma ray emitting nuclides Evaluation algorithm certified Suits for routine measurements Applications -Food contamination -Health physics contamination control -Construction material (Slag, Dust) -Metal products -Experiments or Studies based on Monitoring -of radioactive Markers 10
11 Remote monitoring stations Long term spectral analysis Sensitive dose rate monitors Pre warning points Remote movable receptors in Wi-Fi or GSM network Applications - External Monitoring of Nuclear Power plants or facilities - Long term monitoring of deposits - Monitors for illicit traficking 11
12 Industrial Applications Control of processing using tracers Leakage monitoring Slag, scum monitoring Quality check of materials on entry Product monitoring and certification Applications - Metalurgy - Rafineries - Chemistry - Pipelines 12
13 GT-40 Working Modes Scintillometer Profile recording x scale synchronised with actual time Advanced profile browser - Rewind and zoom function - Browse function accessible any time without interrupting current recording (Search function switched on backstage) Static of Float Background level for Alarms Dose rate and Dose Indication Acoustic indication of Exposure rate 13
14 GT-40 Working Modes Gamma Ray Spectrometer Full Digital, sampling frequency 40 MHz Energy range 15 kev 3 MeV Pileup rejector proportional pulse shape control Spectrum linearization, high throughput Advanced Gain shift compensation (operation range 15 kev 3.5 MeV) Comfortable spectrum browser Y scaling, moving cursor and zooming ASSAY results screen preliminary results update every 30 seconds Nuclide Identification screen list of peaks found and amplitudes 14
15 GT-40 Working Modes Gamma Ray Spectrometer for Core Measurement Core identification interface with automated depth counter for faster processing Editable formula for API or other units 15
16 GT-40 methods Maximum 6 components (elements) Space for 6 selectable methods (calibrations) Methods upgradeable from PC database incl cal. spectra User customized calibrations w/o sw change requirement 16
17 GT-40 methods Virtual Components Gate to using special formulas API AI Activity Index GI Gamma Index User Defined 17
18 GT-40 methods Calibration spectra archived in the unit. Automated recalibration prior every measurement allows changing measurement circumstances any time. For example re selection of analysed parts of spectra ROI. Elements can be analysed from whole spectrum or its parts ROIs (signal to noise ratio). 18
19 GT-40 methods New Measurement Methods can be assembled from archived spectra. Each Method setup is exportable to a PC => simple unit re calibration from PC database. Number of components in a method can be changed any time (ADD componet or REMOVE) 19
20 MCA performance Uniformity of spectra of two different units = key to team work of multiple units 20
21 Concentration [kbq/m2] Detection performance Least Detectable Activities of Cs 137 and Cs 134 in soil in kbq/m 2 for various measurement times GT-40 Least Detection Concentrations 1,00 0,90 0,89 0,80 0,70 0,60 0,50 0,46 0,51 0,40 Cs-137 0,40 0,30 0,20 0,27 0,21 0,28 0,15 0,23 0,12 Cs-134 0,10 0, Measuring time [s] 21
22 Communication Maintenance Worldwide access to the unit via internet. Comfortable SW upgrade Performance check and service Implementation of new measurement methods Remote operation measurement and monitoring Cooperation with the other devices Direct control of sample changers, pumps or valves 22
23 Spectrum Browser Movable Cursor for inspection of each channel Zoom function for detailed look Y Axis scalable 23
24 Joystick operation Five buttons directions UP, DOWN, LEFT and RIGHT. OK as ENTER Menu interface with simple navigation - expected buttons are illuminated 24
25 Software Solution SQL DATABASE for data and logs in the unit Build in Browser for Results, Spectra and Logs Support for instruments setup Remote Control Tool Plug in ready Detailed Logs for diagnostic 25
26 Where you can find us Since 2006 we manufactured and distributed 6000 instruments deployed overall the world. Our biggest customers are in Canada, Australia and Brazil. Instruments work in polar areas as well as in tropical forests in Africa. Our units helps in driest deserts in Saudi and Australia. You can find them 1500 m below surface or flying m on planes. We are proud we are helping you. GEORADIS s.r.o. Novomoravanska Brno Czech Republic Europe Georadis s.r.o
IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications
fire IdentiFINDER Digital Hand Held Spectrometer & The world s smallest spectrometer and dose rate meter designed for portable applications. safety security identifinder - CH (yellow) CZT and neutron detector
More informationQuantumMCA QuantumNaI QuantumGe QuantumGold
QuantumMCA QuantumNaI QuantumGe QuantumGold Berkeley Nucleonics Corporation (San Rafael, CA) and Princeton Gamma Tech (Princeton, NJ) have partnered to offer gamma spectroscopy with either germanium or
More informationM E E T I n s t r u m e n t s G.m.b.H.
T a m a r i s k e n g a s s e 1 0 2 / 1 3 / 5 A - 1 2 2 0 V i e n n a, A U S T R I A T e l : + 4 3 1 2 8 5 4 5 7 2, F a x : + 4 3 1 2 8 3 6 4 2 9 E - m a i l : office@mateval.com www.mateval.com Portable
More informationCharacterization of Large Structures & Components
Structures & Components KEY BENEFITS Key Drivers: Lack of good knowledge about the position, the identification and the radiological specification of contamination on or inside large components. Significant
More informationGEOPHYSICAL GAMMA-RAY SPECTROMETER
CZECH REPUBLIC GEOPHYSICAL GAMMA-RAY SPECTROMETER GRM-260 Operating Manual Version 2.0 Brno, October 2001 Contents Technical specifications 3 1. Theory 4 2. Operating Instructions 7 2.1. GRM-260 Preparation
More informationIntroduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48
Introduction to Environmental Measurement Techniques 2016 Radioactivity Dana Pittauer (dpittauer@marum.de) 1of 48 Introduction Radioisotopes are of interest in environmental physics for several reasons:
More informationPYCKO SCIENTIFIC LIMITED
PYCKO SCIENTIFIC LIMITED 31 London Road, Grantham, NG31 6EX Telephone 01476 401992 bill@pycko.co.uk www.pycko.co.uk Your Alternative To The Obvious RayMon10 TM Detect, measure, identify and analyse radionuclides
More informationɣ-radiochromatography
nuclear instruments Kapitel_y_Graphy.indd 1 19.08.09 10:27 n u c l e a r i n s t r u m e n t s Index HPLC-detectors TLC-detectors GABI* analog output GABI* digital output to PC minigita*, 1 trace scanner
More informationRenewed whole-body counting chamber in STUK
Renewed whole-body counting chamber in STUK Seminar DTU Nutech, Roskilde, Denmark Tiina Torvela, Tero Karhunen, Maarit Muikku Environmental Radiation Surveillance and Emergency Preparedness Whole-body
More informationFRAM V5.2. Plutonium and Uranium Isotopic Analysis Software
V5.2 Plutonium and Uranium Isotopic Analysis Software Advanced Isotopic Ratio Analysis Software for HPGe Gamma-Ray Spectra Analyzes Pu, and a wide variety of heterogeneous samples containing Pu, Am, U,
More information1 of :32
Home Page Products Price List Links & PDFs DISCONTINUED: SEE GAMMA-RAD Gamma Ray & X-Ray Spectroscopy System Hand-Held, High Efficiency NaI(Tl) Detector The GAMMA-8000 is a powerful, portable instrument
More information1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer
1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer PerkinElmer LAS (UK) Ltd, Chalfont Rd, Seer Green, Beaconsfield, Bucks HP9 2FX tel: 0800 896046 www.perkinelmer.com John Davies January
More informationRadioactive Waste Management
International Journal of Research in Engineering and Science (IJRES) ISSN (Online): 2320-9364, ISSN (Print): 2320-9356 Volume 4 Issue 6 ǁ June. 2016 ǁ PP.67-71 Asma Osman Ibrahim Osman 1, Hamid Mohamed
More informationWiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher
Wiper Gold Edition Premium Wipe Test Counter Setting the bar higher Software - Simplicity, Re-defined Load your wipe into the well and press the button. Your wipe is counted and automatically converted
More informationPINS3-CF. Portable Chemical and Explosive Identification System
Portable Chemical and Explosive Identification System Portable Isotopic Neutron Spectroscopy System for the Identification of Chemical Warfare Agents, Explosives, and Toxic Industrial Chemicals without
More informationGamma-Spectrum Generator
1st Advanced Training Course ITCM with NUCLEONICA, Karlsruhe, Germany, 22-24 April, 2009 1 Gamma-Spectrum Generator A.N. Berlizov ITU - Institute for Transuranium Elements Karlsruhe - Germany http://itu.jrc.ec.europa.eu/
More informationRADEAGLET. Lightweight Handheld Radioisotope Identification Device
RADEAGLET Lightweight Handheld Radioisotope Identification Device Weighing Only 900 grams, the RADEAGLET is the Lightest HH-RIID in the world! The Perfect Instrument for First Responders Who Need to Wear
More informationISOCS / LabSOCS. Calibration software for Gamma Spectroscopy
ISOCS / LabSOCS Calibration software for Gamma Spectroscopy Counts Setup Hardware Peak Shaping Parameters Rise Time Flat Top Pole-zero Number of Channels Signal Gain Setting up a detector for measurement
More informationLATE PHASE OF NUCLEAR ACCIDENT IN AGRICULTURE WEAKNESSES IN DECISION MAKING DUE TO LACK OF DATA, KNOWLEDGE AND SKILL AND POSSIBLE INNOVATION
IAEA expert meeting on Radiation Protection after Fukushima Accident, Vienna 17-21 Feb 2014 LATE PHASE OF NUCLEAR ACCIDENT IN AGRICULTURE WEAKNESSES IN DECISION MAKING DUE TO LACK OF DATA, KNOWLEDGE AND
More informationQuality Assurance. Purity control. Polycrystalline Ingots
Quality Assurance Purity control Polycrystalline Ingots 1 Gamma Spectrometry Nuclide Identification Detection of Impurity Traces 1.1 Nuclides Notation: Atomic Mass Atomic Number Element Neutron Atomic
More informationApplied Nuclear Science Educational, Training & Simulation Systems
WWW.NATS-USA.COM Applied Nuclear Science Educational, Training & Simulation Systems North American Technical Services Bridging Technology with the Latest in Radiation Detection Systems The Center For Innovative
More informationINSTRUMENTAL NEUTRON ACTIVATION ANALYSIS (INAA)
Instrumental neutron activation analysis (INAA) is used to determine the concentration of trace and major elements in a variety of matrices. A sample is subjected to a neutron flux and radioactive nuclides
More informationPractical Solutions to Radioactive Waste Characterization
Practical Solutions to Radioactive Waste Characterization Ronald Keyser, Timothy Twomey EG&G ORTEC Richard Hagenauer Lockheed Martin Energy Systems, Oak Ridge, TN Abstract The movement or storage of containers
More informationWiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher
Wiper Gold Edition Premium Wipe Test Counter This product is available through: JRT Associates 5 Nepperhan Avenue, Suite 2B Elmsford, NY 10523 800-221-0111 Setting the bar higher Software - Simplicity,
More informationDose Reconstruction Methods and Source Term Assessment using Data from Monitoring Networks and Mobile Teams A German Approach
Dose Reconstruction Methods and Source Term Assessment using Data from Monitoring Networks and Mobile Teams A German Approach M. Bleher, U. Stöhlker, F. Gering Federal Office for Radiation Protection (BfS),
More informationIntroduction to Fourier Transform Infrared Spectroscopy
molecular spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Part of Thermo Fisher Scientific Introduction What is FT-IR? FT-IR stands for Fourier Transform InfraRed, the preferred method
More informationDistance from the face of the detector to the surface of the item being measured.
ORTEC Using the ORTEC ISO-CART and ISOTOPIC This guide is designed to assist the user of an ISO-CART /ISOTOPIC system in performing accurate nondestructive measurements of radioactive items in various
More informationPINS3-CW. Portable Chemical Identification System
Portable Chemical Identification System Portable Isotopic Neutron Spectroscopy System for the Identification of Chemical Warfare Agents, and Toxic Industrial Chemicals without the need for Liquid Nitrogen.
More informationNUCL 3000/5030 Laboratory 2 Fall 2013
Lab #2: Passive Gamma Spec Measurements in Decoding Natural Radioactivity in SLC Area Objectives a. Learn basics of gamma spectroscopy b. Learn the equipment in Counting stations #4, #5 and #8 c. Apply
More information4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.
EXPERIMENT 2.1 GAMMA ENERGY CALIBRATION 1- Turn the power supply on to 900 V. Turn the NIM crate on to power the amplifiers. Turn the Oscilloscope on to check the gamma pulses. The main amplifier should
More informationWhite Paper - SkyTEM Multi Geophysical Airborne Surveys
White Paper - SkyTEM Multi Geophysical Airborne Surveys (TDEM / Magnetic and Gamma-Ray Spectrometry) Tomas Grand Han Limburg Bill Brown SkyTEM Surveys Medusa BV SkyTEM Surveys Denmark The Netherlands Denmark
More informationCZT Gamma Spectrometry Applied to the In-situ Characterisation of Radioactive Contaminations
CZT Gamma Spectrometry Applied to the In-situ Characterisation of Radioactive Contaminations Alain Rocher (EDF/DPN; e-mail : alain.rocher@edf.fr) Leon Piotrowski (EDF/R&D; e-mail : leon.piotrowski@edf.fr)
More informationAcoustics and Ionising Radiation Formulation and Strategy. 13 November 2008 Alan DuSautoy
Acoustics and Ionising Radiation Formulation and Strategy 13 November 2008 Alan DuSautoy Contents What is the future of Programme Formulation? What is Rolling Formulation? Programme Overview Roadmaps Future
More informationTECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL
NUCLE A R FORENSIC S INTERN ATION A L TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL This document was designed
More informationMobile Unit for Site Characterization: Results of a Demonstration Event
Mobile Unit for Site Characterization: Results of a Demonstration Event Román Padilla Alvarez Nuclear Spectrometry and Applications Laboratory Department of Nuclear Sciences and Applications, Horst Monken
More informationA Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 49, NO. 3, JUNE 2002 1547 A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate Wanno Lee, Gyuseong Cho, and Ho
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More informationPreparation of Standard Source as a Petri Dish for Plant by Using
Preparation of Standard Source as a Petri Dish for Plant by Using 152 Eu Element Khalid H. AL-Ubaidi 1 Salam K. AL-Nasri 2 Auday T. AL-Bayati 1* 1.Department of Physics, College of Education / Ibn Al-
More informationAUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING
ABSTRACT AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING J. Rynes, K.M.F. Biegalski, P. Donohoe, and S. Biegalski Veridian Pacific-Sierra Research
More informationCapeSym, Inc. Radiation Detection Solutions
ScintiClear Plug & Play Developer Kit ScintiClear Developer Kit Our developer kit is a plug-and-play high energy resolution gamma spectrometer ready to measure in less than 30 minutes after the box is
More informationThe Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine!
The Multi-Wiper HE High Energy Nuclear Medicine Well Counter The first multi-well counters designed specifically for Nuclear Medicine! * Comprehensive wipe testing with concise report in DPM * Available
More informationß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output.
www.raytest.com Choose your application of ß + RADIATION chromatography stand alone software controlled chemical purity HPLC PET GABI 2x2 Nal (Tl) 0 1V output PET GABI 2x2 Nal (Tl) Gina-PCcontrolled TLC
More informationWM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA
The Underwater Spectrometric System Based on CZT Detector for Survey of the Bottom of MR Reactor Pool 13461 Victor Potapov, Alexey Safronov, Oleg Ivanov, Sergey Smirnov, Vyacheslav Stepanov National Research
More informationWM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA
Testing and Performance Validation of a Sensitive Gamma Ray Camera Designed for Radiation Detection and Decommissioning Measurements in Nuclear Facilities- 13044 John A. Mason*, Richard Creed**, Marc R.
More informationWM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA
Determination of Components of Fuel Matrix in Water and in Bottom Slimes in the MR Reactor Ponds in NRC Kurchatov Institute 14038 Alexey Stepanov *, Iurii Simirskii *, Ilya Semin *, Anatoly Volkovich *
More informationInvestigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC
Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC A. Specification Whole body counting method is used to detect the gamma rays emitted by radio nuclides,
More informationDependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution
Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution Chikkappa Udagani Abstract: This paper presents the precise method to estimate the dependence of linear and mass
More informationGeneral Overview of Radiation Detection and Equipment
www.inl.gov INL/MIS-11-22727 General Overview of Radiation Detection and Equipment International Nuclear Safeguards Policy and Information Analysis Course Monterey Institute of International Studies June
More information"Neutron Flux Distribution"
TECHNICAL UNIVERSITY DRESDEN Institute of Power Engineering Training Reactor Reactor Training Course Experiment "Neutron Flux Distribution" Instruction for Experiment Neutron Flux Distribution Content:
More informationSCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION
SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION OBJECTIVE The primary objective of this experiment is to use an NaI(Tl) detector, photomultiplier tube and multichannel analyzer software system
More informationEM 27/SUN Series. Innovation with Integrity. For Atmospheric Measurements FT-IR
EM 27/SUN Series For Atmospheric Measurements Innovation with Integrity FT-IR The new EM27/SUN Series spectrometers represent FT-IR Remote Sensing analyzers dedicated for atmospheric measurements. They
More informationRADEAGLE. Next Generation Radioisotope Identification Device. Detection and Identification: Fast, Accurate and Easy
RADEAGLE Next Generation Radioisotope Identification Device Detection and Identification: Fast, Accurate and Easy RADEAGLE RADEAGLE is a state-of-the-art handheld, radioisotope identification device (RIID)
More informationRMCC CANBERRA Latest developments
RMCC -2015 CANBERRA Latest developments Daniel Obrecht International Sales Manager CANBERRA Worldwide Presence 50 years in business Over 1,000 employees 7 industrial sites Canada Sweden Germany Belgium
More informationIDENTIFICATION AND QUANTIFICATION OF RADIONUCLIDES IN HISTORICAL WASTE AT ANSTO
IDENTIFICATION AND QUANTIFICATION OF RADIONUCLIDES IN HISTORICAL WASTE AT ANSTO McOrist G D., Bowles C.J., Fernando K. and Wong R. Australian Nuclear Science and Technology Organisation Australia Abstract
More informationFoodScreen Radiological Food Screening System
Features Rapid screening of processed or raw food products for key 131I, 134 Cs and 137 Cs nuclides Clear, immediate indication if any nuclide-specific maximum permissible concentrations are exceeded Transportable
More informationResearch Gamma Counter
Research Gamma Counter Multi-Detector Gamma Counters High performance gamma counters for RIA and research applications Complete data reduction for all RIA, IRMA, Radio and Research assays Selectable dual
More informationEmpowering water/wastewater network management with GIS
Empowering water/wastewater network management with GIS Ioannis Kavouras_GIS Manager Surveying Engineer, MSc, MBA The Company responsible for fresh water distribution & sanitation serving 1.500.000 citizens
More informationHEROICA: a test facility for the characterization of BEGe detectors for the GERDA experiment
Physikalisches Institut Kepler Center for Astro and Particle Physics : a test facility for the characterization of BEGe detectors for the GERDA experiment Raphael Falkenstein for the GERDA collaboration
More information7 th International Summer School 2015, JRC Ispra: Operational Issues in Radioactive Waste Management and Nuclear Decommissioning
7 th International Summer School 2015, JRC Ispra: Operational Issues in Radioactive Waste Management and Nuclear Decommissioning Nucleonica: Nuclear Applications for Radioactive Waste Management and Decommissioning
More informationMAPPING OF DOSE-RATE OF GAMMA-IRRADIATION BY 137 Cs OVER THE EARTH SURFACE FOR THE TERRITORY OF RUSSIA
MAPPING OF DOSE-RATE OF GAMMA-IRRADIATION BY 137 Cs OVER THE EARTH SURFACE FOR THE TERRITORY OF RUSSIA Yu.A.Izrael, E.V.Kvasnikova, I.M.Nazarov, A.N.Pegoev, E.D.Stukin Institute of Global Climate and Ecology,
More informationGAMMA RAY SPECTROSCOPY
GAMMA RAY SPECTROSCOPY Gamma Ray Spectroscopy 1 In this experiment you will use a sodium iodide (NaI) detector along with a multichannel analyzer (MCA) to measure gamma ray energies from energy level transitions
More information8 th International Summer School 2016, JRC Ispra on Nuclear Decommissioning and Waste Management
8 th International Summer School 2016, JRC Ispra on Nuclear Decommissioning and Waste Management Nucleonica: Nuclear Applications for Radioactive Waste Management and Decommissioning cloud based nuclear
More informationDetection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR
Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR Ensuring ultimate cleanliness for maximum adhesion Application Note Author John Seelenbinder Agilent Technologies,
More informationWM 07 Conference, February 25 March 01, 2007, Tucson, AZ
Design and Construction of a High Energy X-Ray R&D Facility, and the Development and Optimization of Real Time Radioisotopic Characterization of Remote Handled Waste at MeV Energies. S. Halliwell, V.J.Technologies
More informationA gamma-gamma coincidence spectrometer for nuclear attribution and safeguard applications
IAEA-CN-184/174 A gamma-gamma coincidence spectrometer for nuclear attribution and safeguard applications Weihua Zhang, Jing Yi, Pawel Mekarski and Kurt Ungar Radiation Protection Bureau of Health Canada,
More informationShielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis
Shielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis The shielded γ-ray spectrometer of Dr. Westmeier GmbH employs a NaI(Tl) or other scintillation detector with good resolution inside
More informationREX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219
REX Evaluation Guide American Micro Detection Systems Inc. 2800 March Lane, Suite 200 Stockton, CA 95219 I. INTRODUCTION REX (Real-time Elemental X-ray Fluorescence System) is the only instrument capable
More informationEnergy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples
Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples Mashaba, Machel. 1*, Kotze, Deon. 2, Tshivhase, Victor.M. 1, Faanhof, Arnaud. 1, 2 1
More informationEuropean Project Metrology for Radioactive Waste Management
European Project Metrology for Radioactive Waste Management Petr Kovar Czech Metrology Institute Okruzni 31 638 00, Brno, Czech republic pkovar@cmi.cz Jiri Suran Czech Metrology Institute Okruzni 31 638
More informationMSCL-S: MULTI-SENSOR CORE LOGGER NON-DESTRUCTIVE CONTINUOUS CORE SCANNING FOR INDUSTRY & RESEARCH
MSCL-S: MULTI-SENSOR CORE LOGGER NON-DESTRUCTIVE CONTINUOUS CORE SCANNING FOR INDUSTRY & RESEARCH IF CORE S WORTH TAKING, IT S WORTH LOGGING AUTOMATED & FLEXIBLE CORE LOGGING & SCANNING The Geotek Standard
More informationIAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES
IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES V. MAIOROV, A. CIURAPINSKI, W. RAAB and V. JANSTA Safeguards Analytical Laboratory, International Atomic Energy
More informationXA TERRESTRIAL GAMMA DOSE RATE MAPS, THEIR COMPILATION AND VERIFICATION RADIOMETRIC MAP OF THE CZECH REPUBLIC
TERRESTRIAL GAMMA DOSE RATE MAPS, THEIR COMPILATION AND VERIFICATION RADIOMETRIC MAP OF THE CZECH REPUBLIC XA9745936 M. MATOLIN Faculty of Science, Charles University, Prague, Czech Republic Abstract Maps
More informationAnalysis of natural radioactivity and artificial radionuclides in soil samples in the Najran region of Saudi Arabia
Safety and Security Engineering V 675 Analysis of natural radioactivity and artificial radionuclides in soil samples in the Najran region of Saudi Arabia A. Al-Zahrany & K. S. Al-Mogabes Institute of Atomic
More informationRinghals AB. Routines for whole body counting at Ringhals NPP
Routines for whole body counting at Ringhals NPP Structure Equipment - Quick Scan - Whole body counter Marie Carlson M.Sc. Radiology and Dosimetry Radiation Physicist and deputy RP Controller Routines
More informationInvestigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL
Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL A. Specification Gamma-spectrometry method is used to identify and determine the activity concentration
More informationRADIATION MONITORING NETWORKS and some results from the reactor accident in Fukushima
RADIATION MONITORING NETWORKS and some results from the reactor accident in Fukushima Sixth Annual Workshop on Radiation Measurement Cross Calibration Project June 13-15, 2011 Middle East Scientific Institute
More informationLS6500 Scintillation Counting Systems
LS6500 Scintillation Counting Systems Agenda LS6500 Concepts and Design H# Plus - The Basis of Advanced Technology Low Level Counting Alpha/Beta Discrimination LS6500 Concepts Give reproducible results
More informationEnvironmental Applications
Environmental Applications Gamma ray Spectrometry Paul Nolan University of Liverpool Gamma ray spectrometry of environmental samples is a standard technique Germanium detector Programs available for spectrum
More informationSLAC Radioanalysis Laboratory
SLAC Radioanalysis Laboratory Henry Brogonia Dosimetry and Radiological Protection Group (DREP) DOE Environmental Radiation Protection Program Review (July 23-24, 2007) Radioanalysis Laboratory Mission
More information28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING
DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING W. Hennig 1, H. Tan 1, A. Fallu-Labruyere 1, W. K. Warburton 1, J. I. McIntyre 2, A. Gleyzer 3 XIA, LLC 1, Pacific Northwest National Laboratory
More informationRADIATION PROTECTION
DEPARTMENT OF NUCLEAR TECHNOLOGY, FACULTY OF ENGINEERING CHULALONGKORN UNIVERSITY PHAYATHAI ROAD, BANGKOK 10330, THAILAND TEL: (662) 218-6772, (662) 218-6784. FAX: (662) 218-6770 E-mail: fnegbr@eng.chula.ac.th
More informationIEC Tritium Standard
detect and identify IEC 62303 Tritium Standard Dr. Alfred Klett Berthold Technologies, Bad Wildbad, Germany 21 st Annual Air Monitoring Users Group (AMUG) Meeting Palace Station Hotel, Las Vegas, Nevada,
More informationInformation about the effects of the reactor disaster in Fukushima on the worldwide networked
We make radiation measureable! Information about the effects of the reactor disaster in Fukushima on the worldwide networked economy Detect radiation in a reliable way www.sea-duelmen.de The reactor disaster
More informationBOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION
BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION
More informationAdvanced Gamma Spectroscopy
Nuclear Division Scientech Advanced Gamma Spectroscopy Spin and Parity of ground state 18 Sb124 20.2 m IT 26.0, e γ 10.9D,e 5+ 1.6m IT 10.9,e β 1.2,... γ 602.7,645.8 498.4,... 3 60.20 d β.61, 2.301, γ
More informationPulsar. Delivering NMR to your benchtop
Pulsar NMR Delivering NMR to your benchtop Pulsar TM NMR for your laboratory The Pulsar TM NMR spectrometer from Oxford Instruments delivers affordable, high performance NMR spectroscopy into the laboratory
More informationApplied Nuclear Science Educational, Training & Simulation Systems
WWW.NATS-USA.COM Applied Nuclear Science Educational, Training & Simulation Systems North American Technical Services Bridging Technology With The Latest in Radiation Detection Systems & Training Solutions
More informationOn-line XRF analysis of multiple elements in liquid process streams C-QUAND
An ideal tool for multiple element analysis using on-line XRF technology, from low ppm to percentage levels C-QUAND On-line XRF analysis of multiple elements in liquid process streams Introduction The
More informationInteractive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools
10th Nuclear Science Training Course with NUCLEONICA, Cesme, Turkey, 8-10 October, 2008 1 Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools A.N. Berlizov ITU - Institute for Transuranium
More informationORTEC was founded in 1960 by researchers from Oak Ridge National Labs to commercialize charged particle detectors
DAVIDE SACCHI 1 ORTEC Overview ORTEC was founded in 1960 by researchers from Oak Ridge National Labs to commercialize charged particle detectors Headquarters: Oak Ridge, TN with global sales and service
More informationOXEA - Online Elemental Analyzer
02 25 08 OXEA - Online Elemental Analyzer OXEA (Online X-ray Elemental Analyzer) is based on the X-ray fluorescence technology (XRF) which is well known in the laboratory field. With the aid of a patented
More informationInternational Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN
316 Effective atomic number of composite materials by Compton scattering - nondestructive evaluation method Kiran K U a, Ravindraswami K b, Eshwarappa K M a and Somashekarappa H M c* a Government Science
More informationDesign and production of Scintillation Detectors
Design and production of Scintillation Detectors Components for nuclear radiation detectors Fields of application: * Medicine * Industry * Science * Security Scintillation Detectors : Instruments using
More informationNew happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist
New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist Genie-2000 Latest Features Cascade Summing Correction LACE (Line Activity Consistency Evaluator) Interactive Nuclide
More informationTerrestrial gamma dose rates along one of the coastal highways in Sri Lanka
Sri Lankan Journal of Physics, Vol. 2 (21) 1-6 Institute of Physics - Sri Lanka Terrestrial gamma dose rates along one of the coastal highways in Sri Lanka C.S. Sumithrarachchi and R. Hewamanna * Department
More informationD501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect
Microscanner D-Series The Only Certified Accurate Surface Instruments in the World A MUST FOR ISO 9001 ISO 9002 ISO 9003 TRACEABILITY PROGRAMS Common Surface Measurement Errors D501 and D501-RS Microscanner
More informationAlpha-Energies of different sources with Multi Channel Analyzer
Physical Structure of Matter Radioactivity Alpha-Energies of different sources with Multi Channel Analyzer What you can learn about Decay series Radioactive equilibrium Isotopic properties Decay energy
More informationFinnigan LCQ Advantage MAX
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer
More informationA Digital Method for Dead Time Compensation in Nuclear Spectroscopy
A Digital Method for Dead Time Compensation in Nuclear Spectroscopy Keyser, Ronald M., Gedcke, Dale A., Upp, Daniel L., Twomey, Timothy R., and Bingham, Russell D. ORTEC, PerkinElmer Instruments, Inc.
More information