GT-40/GT-40S Multipurpose Gamma-Ray Spectrometer Ancestors: GS-256 by Geofyzika Brno 1975 GR-256 by Exploranium Canada 1977 GR-320 by Exploranium

Size: px
Start display at page:

Download "GT-40/GT-40S Multipurpose Gamma-Ray Spectrometer Ancestors: GS-256 by Geofyzika Brno 1975 GR-256 by Exploranium Canada 1977 GR-320 by Exploranium"

Transcription

1 GT-40/GT-40S Multipurpose Gamma-Ray Spectrometer Ancestors: GS-256 by Geofyzika Brno 1975 GR-256 by Exploranium Canada 1977 GR-320 by Exploranium Canada

2 What is common on the current market Handheld Spectrometer for Gamma-Ray NaI/Tl 3x3 or 2x2 BGO Battery powered Methods for NORM Radionuclides Assay 1024 channels analyser (MCA) 2

3 What is new Single unit with detector and all electronic build in one case Fully digital spectrometer Spectra free of differential nonlinearity 1: Full spectra linearization during conversion; Energy calibration 3 kev / channel Proportional gain compensation on backstage using natural BG spectral pattern Color trans reflective display the more light the better readability Powerful CPU with embedded Linux TCP/IP WLAN GPS build in the unit Voice recorder 3

4 What is unique Math methods for advanced ASSAY evaluation of activities using least square fitting of spectral shape Very high sensitivity and dynamic range and minimal components crosstalk (20 Bq/kg Cs-137 on 400 ppm U) High Accuracy Multiple measurement calibrations - Methods Removable lead collimator GT-40S Easy integration in automated processes (Sample changers, position control etc.) 4

5 Why GT-40 / GT-40S One unit for plenty of application All in one powerful computer and gamma-ray detector Sensitive search Data Recorder with new Browser Worldwide access via internet remote maintenance Easy remote operation Team work with other GT-40S Applications NORM Field Spectroscopy - Man-made contamination - Core logging - Construction Building Materials control - Easy Lab Unit - Remote station - Industry 5

6 NORM in Geo ASSAY of K, U and Th in various geometries (infinite area, intrusions in outcrops, boreholes, caves Combination of K, U, Th assay with surface contamination measurement (Cs-137 or other nuclides in Bq/m 2 Chernobyl, Fukushima) Determination of ratio between U and Ra User adjustable formula for traditional Values and units e.g. eu, eth, K/U.. Applications Exploration - Mineralogy - Petrophysics - Mining - Building industry 6

7 Man-made contamination/environment Targeting of Radioactive Sources Nuclide Identification including Categories and Intensities Activity evaluation in various units (Bq, Ci, volume, mass or area activities) Long term monitoring in predefined tasks for permanent surveillance Applications Cleaning of contaminated areas or technologies - Waste water management - Long term local background monitoring - Waste deposits - Land contamination Screening - Traceing methods 7

8 Core logging Adaptable in variety of shieldings Internal collimator for higher resolution Calibrations for different core diameters K, U, Th response API, Total or Dose Rate Automated depth control for faster measurement Applications - Stratigraphy - Mineralogy - Oil and Gas - Mining 8

9 Construction Building Materials Certification Activity Index, Gamma Index, Radon Index Buildings sanitation Applications Sick Houses monitoring Raw Material Certification Construction Materials Defectoscopy Exploatation strategy 9

10 Lab Applications and Experimental Lab Kit (GT-40 with desktop shielding and calibration set) for High sensitivity measurement Short measuring times Minimal Operation costs (No liquid nitrogen) Up six different Radioelements analyse and activity evaluation in mixtures per method Capable to identify over 150 gamma ray emitting nuclides Evaluation algorithm certified Suits for routine measurements Applications -Food contamination -Health physics contamination control -Construction material (Slag, Dust) -Metal products -Experiments or Studies based on Monitoring -of radioactive Markers 10

11 Remote monitoring stations Long term spectral analysis Sensitive dose rate monitors Pre warning points Remote movable receptors in Wi-Fi or GSM network Applications - External Monitoring of Nuclear Power plants or facilities - Long term monitoring of deposits - Monitors for illicit traficking 11

12 Industrial Applications Control of processing using tracers Leakage monitoring Slag, scum monitoring Quality check of materials on entry Product monitoring and certification Applications - Metalurgy - Rafineries - Chemistry - Pipelines 12

13 GT-40 Working Modes Scintillometer Profile recording x scale synchronised with actual time Advanced profile browser - Rewind and zoom function - Browse function accessible any time without interrupting current recording (Search function switched on backstage) Static of Float Background level for Alarms Dose rate and Dose Indication Acoustic indication of Exposure rate 13

14 GT-40 Working Modes Gamma Ray Spectrometer Full Digital, sampling frequency 40 MHz Energy range 15 kev 3 MeV Pileup rejector proportional pulse shape control Spectrum linearization, high throughput Advanced Gain shift compensation (operation range 15 kev 3.5 MeV) Comfortable spectrum browser Y scaling, moving cursor and zooming ASSAY results screen preliminary results update every 30 seconds Nuclide Identification screen list of peaks found and amplitudes 14

15 GT-40 Working Modes Gamma Ray Spectrometer for Core Measurement Core identification interface with automated depth counter for faster processing Editable formula for API or other units 15

16 GT-40 methods Maximum 6 components (elements) Space for 6 selectable methods (calibrations) Methods upgradeable from PC database incl cal. spectra User customized calibrations w/o sw change requirement 16

17 GT-40 methods Virtual Components Gate to using special formulas API AI Activity Index GI Gamma Index User Defined 17

18 GT-40 methods Calibration spectra archived in the unit. Automated recalibration prior every measurement allows changing measurement circumstances any time. For example re selection of analysed parts of spectra ROI. Elements can be analysed from whole spectrum or its parts ROIs (signal to noise ratio). 18

19 GT-40 methods New Measurement Methods can be assembled from archived spectra. Each Method setup is exportable to a PC => simple unit re calibration from PC database. Number of components in a method can be changed any time (ADD componet or REMOVE) 19

20 MCA performance Uniformity of spectra of two different units = key to team work of multiple units 20

21 Concentration [kbq/m2] Detection performance Least Detectable Activities of Cs 137 and Cs 134 in soil in kbq/m 2 for various measurement times GT-40 Least Detection Concentrations 1,00 0,90 0,89 0,80 0,70 0,60 0,50 0,46 0,51 0,40 Cs-137 0,40 0,30 0,20 0,27 0,21 0,28 0,15 0,23 0,12 Cs-134 0,10 0, Measuring time [s] 21

22 Communication Maintenance Worldwide access to the unit via internet. Comfortable SW upgrade Performance check and service Implementation of new measurement methods Remote operation measurement and monitoring Cooperation with the other devices Direct control of sample changers, pumps or valves 22

23 Spectrum Browser Movable Cursor for inspection of each channel Zoom function for detailed look Y Axis scalable 23

24 Joystick operation Five buttons directions UP, DOWN, LEFT and RIGHT. OK as ENTER Menu interface with simple navigation - expected buttons are illuminated 24

25 Software Solution SQL DATABASE for data and logs in the unit Build in Browser for Results, Spectra and Logs Support for instruments setup Remote Control Tool Plug in ready Detailed Logs for diagnostic 25

26 Where you can find us Since 2006 we manufactured and distributed 6000 instruments deployed overall the world. Our biggest customers are in Canada, Australia and Brazil. Instruments work in polar areas as well as in tropical forests in Africa. Our units helps in driest deserts in Saudi and Australia. You can find them 1500 m below surface or flying m on planes. We are proud we are helping you. GEORADIS s.r.o. Novomoravanska Brno Czech Republic Europe Georadis s.r.o

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications fire IdentiFINDER Digital Hand Held Spectrometer & The world s smallest spectrometer and dose rate meter designed for portable applications. safety security identifinder - CH (yellow) CZT and neutron detector

More information

QuantumMCA QuantumNaI QuantumGe QuantumGold

QuantumMCA QuantumNaI QuantumGe QuantumGold QuantumMCA QuantumNaI QuantumGe QuantumGold Berkeley Nucleonics Corporation (San Rafael, CA) and Princeton Gamma Tech (Princeton, NJ) have partnered to offer gamma spectroscopy with either germanium or

More information

M E E T I n s t r u m e n t s G.m.b.H.

M E E T I n s t r u m e n t s G.m.b.H. T a m a r i s k e n g a s s e 1 0 2 / 1 3 / 5 A - 1 2 2 0 V i e n n a, A U S T R I A T e l : + 4 3 1 2 8 5 4 5 7 2, F a x : + 4 3 1 2 8 3 6 4 2 9 E - m a i l : office@mateval.com www.mateval.com Portable

More information

Characterization of Large Structures & Components

Characterization of Large Structures & Components Structures & Components KEY BENEFITS Key Drivers: Lack of good knowledge about the position, the identification and the radiological specification of contamination on or inside large components. Significant

More information

GEOPHYSICAL GAMMA-RAY SPECTROMETER

GEOPHYSICAL GAMMA-RAY SPECTROMETER CZECH REPUBLIC GEOPHYSICAL GAMMA-RAY SPECTROMETER GRM-260 Operating Manual Version 2.0 Brno, October 2001 Contents Technical specifications 3 1. Theory 4 2. Operating Instructions 7 2.1. GRM-260 Preparation

More information

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48 Introduction to Environmental Measurement Techniques 2016 Radioactivity Dana Pittauer (dpittauer@marum.de) 1of 48 Introduction Radioisotopes are of interest in environmental physics for several reasons:

More information

PYCKO SCIENTIFIC LIMITED

PYCKO SCIENTIFIC LIMITED PYCKO SCIENTIFIC LIMITED 31 London Road, Grantham, NG31 6EX Telephone 01476 401992 bill@pycko.co.uk www.pycko.co.uk Your Alternative To The Obvious RayMon10 TM Detect, measure, identify and analyse radionuclides

More information

ɣ-radiochromatography

ɣ-radiochromatography nuclear instruments Kapitel_y_Graphy.indd 1 19.08.09 10:27 n u c l e a r i n s t r u m e n t s Index HPLC-detectors TLC-detectors GABI* analog output GABI* digital output to PC minigita*, 1 trace scanner

More information

Renewed whole-body counting chamber in STUK

Renewed whole-body counting chamber in STUK Renewed whole-body counting chamber in STUK Seminar DTU Nutech, Roskilde, Denmark Tiina Torvela, Tero Karhunen, Maarit Muikku Environmental Radiation Surveillance and Emergency Preparedness Whole-body

More information

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software V5.2 Plutonium and Uranium Isotopic Analysis Software Advanced Isotopic Ratio Analysis Software for HPGe Gamma-Ray Spectra Analyzes Pu, and a wide variety of heterogeneous samples containing Pu, Am, U,

More information

1 of :32

1 of :32 Home Page Products Price List Links & PDFs DISCONTINUED: SEE GAMMA-RAD Gamma Ray & X-Ray Spectroscopy System Hand-Held, High Efficiency NaI(Tl) Detector The GAMMA-8000 is a powerful, portable instrument

More information

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer 1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer PerkinElmer LAS (UK) Ltd, Chalfont Rd, Seer Green, Beaconsfield, Bucks HP9 2FX tel: 0800 896046 www.perkinelmer.com John Davies January

More information

Radioactive Waste Management

Radioactive Waste Management International Journal of Research in Engineering and Science (IJRES) ISSN (Online): 2320-9364, ISSN (Print): 2320-9356 Volume 4 Issue 6 ǁ June. 2016 ǁ PP.67-71 Asma Osman Ibrahim Osman 1, Hamid Mohamed

More information

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher Wiper Gold Edition Premium Wipe Test Counter Setting the bar higher Software - Simplicity, Re-defined Load your wipe into the well and press the button. Your wipe is counted and automatically converted

More information

PINS3-CF. Portable Chemical and Explosive Identification System

PINS3-CF. Portable Chemical and Explosive Identification System Portable Chemical and Explosive Identification System Portable Isotopic Neutron Spectroscopy System for the Identification of Chemical Warfare Agents, Explosives, and Toxic Industrial Chemicals without

More information

Gamma-Spectrum Generator

Gamma-Spectrum Generator 1st Advanced Training Course ITCM with NUCLEONICA, Karlsruhe, Germany, 22-24 April, 2009 1 Gamma-Spectrum Generator A.N. Berlizov ITU - Institute for Transuranium Elements Karlsruhe - Germany http://itu.jrc.ec.europa.eu/

More information

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

RADEAGLET. Lightweight Handheld Radioisotope Identification Device RADEAGLET Lightweight Handheld Radioisotope Identification Device Weighing Only 900 grams, the RADEAGLET is the Lightest HH-RIID in the world! The Perfect Instrument for First Responders Who Need to Wear

More information

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy ISOCS / LabSOCS Calibration software for Gamma Spectroscopy Counts Setup Hardware Peak Shaping Parameters Rise Time Flat Top Pole-zero Number of Channels Signal Gain Setting up a detector for measurement

More information

LATE PHASE OF NUCLEAR ACCIDENT IN AGRICULTURE WEAKNESSES IN DECISION MAKING DUE TO LACK OF DATA, KNOWLEDGE AND SKILL AND POSSIBLE INNOVATION

LATE PHASE OF NUCLEAR ACCIDENT IN AGRICULTURE WEAKNESSES IN DECISION MAKING DUE TO LACK OF DATA, KNOWLEDGE AND SKILL AND POSSIBLE INNOVATION IAEA expert meeting on Radiation Protection after Fukushima Accident, Vienna 17-21 Feb 2014 LATE PHASE OF NUCLEAR ACCIDENT IN AGRICULTURE WEAKNESSES IN DECISION MAKING DUE TO LACK OF DATA, KNOWLEDGE AND

More information

Quality Assurance. Purity control. Polycrystalline Ingots

Quality Assurance. Purity control. Polycrystalline Ingots Quality Assurance Purity control Polycrystalline Ingots 1 Gamma Spectrometry Nuclide Identification Detection of Impurity Traces 1.1 Nuclides Notation: Atomic Mass Atomic Number Element Neutron Atomic

More information

Applied Nuclear Science Educational, Training & Simulation Systems

Applied Nuclear Science Educational, Training & Simulation Systems WWW.NATS-USA.COM Applied Nuclear Science Educational, Training & Simulation Systems North American Technical Services Bridging Technology with the Latest in Radiation Detection Systems The Center For Innovative

More information

INSTRUMENTAL NEUTRON ACTIVATION ANALYSIS (INAA)

INSTRUMENTAL NEUTRON ACTIVATION ANALYSIS (INAA) Instrumental neutron activation analysis (INAA) is used to determine the concentration of trace and major elements in a variety of matrices. A sample is subjected to a neutron flux and radioactive nuclides

More information

Practical Solutions to Radioactive Waste Characterization

Practical Solutions to Radioactive Waste Characterization Practical Solutions to Radioactive Waste Characterization Ronald Keyser, Timothy Twomey EG&G ORTEC Richard Hagenauer Lockheed Martin Energy Systems, Oak Ridge, TN Abstract The movement or storage of containers

More information

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher Wiper Gold Edition Premium Wipe Test Counter This product is available through: JRT Associates 5 Nepperhan Avenue, Suite 2B Elmsford, NY 10523 800-221-0111 Setting the bar higher Software - Simplicity,

More information

Dose Reconstruction Methods and Source Term Assessment using Data from Monitoring Networks and Mobile Teams A German Approach

Dose Reconstruction Methods and Source Term Assessment using Data from Monitoring Networks and Mobile Teams A German Approach Dose Reconstruction Methods and Source Term Assessment using Data from Monitoring Networks and Mobile Teams A German Approach M. Bleher, U. Stöhlker, F. Gering Federal Office for Radiation Protection (BfS),

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy molecular spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Part of Thermo Fisher Scientific Introduction What is FT-IR? FT-IR stands for Fourier Transform InfraRed, the preferred method

More information

Distance from the face of the detector to the surface of the item being measured.

Distance from the face of the detector to the surface of the item being measured. ORTEC Using the ORTEC ISO-CART and ISOTOPIC This guide is designed to assist the user of an ISO-CART /ISOTOPIC system in performing accurate nondestructive measurements of radioactive items in various

More information

PINS3-CW. Portable Chemical Identification System

PINS3-CW. Portable Chemical Identification System Portable Chemical Identification System Portable Isotopic Neutron Spectroscopy System for the Identification of Chemical Warfare Agents, and Toxic Industrial Chemicals without the need for Liquid Nitrogen.

More information

NUCL 3000/5030 Laboratory 2 Fall 2013

NUCL 3000/5030 Laboratory 2 Fall 2013 Lab #2: Passive Gamma Spec Measurements in Decoding Natural Radioactivity in SLC Area Objectives a. Learn basics of gamma spectroscopy b. Learn the equipment in Counting stations #4, #5 and #8 c. Apply

More information

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values. EXPERIMENT 2.1 GAMMA ENERGY CALIBRATION 1- Turn the power supply on to 900 V. Turn the NIM crate on to power the amplifiers. Turn the Oscilloscope on to check the gamma pulses. The main amplifier should

More information

White Paper - SkyTEM Multi Geophysical Airborne Surveys

White Paper - SkyTEM Multi Geophysical Airborne Surveys White Paper - SkyTEM Multi Geophysical Airborne Surveys (TDEM / Magnetic and Gamma-Ray Spectrometry) Tomas Grand Han Limburg Bill Brown SkyTEM Surveys Medusa BV SkyTEM Surveys Denmark The Netherlands Denmark

More information

CZT Gamma Spectrometry Applied to the In-situ Characterisation of Radioactive Contaminations

CZT Gamma Spectrometry Applied to the In-situ Characterisation of Radioactive Contaminations CZT Gamma Spectrometry Applied to the In-situ Characterisation of Radioactive Contaminations Alain Rocher (EDF/DPN; e-mail : alain.rocher@edf.fr) Leon Piotrowski (EDF/R&D; e-mail : leon.piotrowski@edf.fr)

More information

Acoustics and Ionising Radiation Formulation and Strategy. 13 November 2008 Alan DuSautoy

Acoustics and Ionising Radiation Formulation and Strategy. 13 November 2008 Alan DuSautoy Acoustics and Ionising Radiation Formulation and Strategy 13 November 2008 Alan DuSautoy Contents What is the future of Programme Formulation? What is Rolling Formulation? Programme Overview Roadmaps Future

More information

TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL

TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL NUCLE A R FORENSIC S INTERN ATION A L TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL This document was designed

More information

Mobile Unit for Site Characterization: Results of a Demonstration Event

Mobile Unit for Site Characterization: Results of a Demonstration Event Mobile Unit for Site Characterization: Results of a Demonstration Event Román Padilla Alvarez Nuclear Spectrometry and Applications Laboratory Department of Nuclear Sciences and Applications, Horst Monken

More information

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 49, NO. 3, JUNE 2002 1547 A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate Wanno Lee, Gyuseong Cho, and Ho

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Preparation of Standard Source as a Petri Dish for Plant by Using

Preparation of Standard Source as a Petri Dish for Plant by Using Preparation of Standard Source as a Petri Dish for Plant by Using 152 Eu Element Khalid H. AL-Ubaidi 1 Salam K. AL-Nasri 2 Auday T. AL-Bayati 1* 1.Department of Physics, College of Education / Ibn Al-

More information

AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING

AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING ABSTRACT AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING J. Rynes, K.M.F. Biegalski, P. Donohoe, and S. Biegalski Veridian Pacific-Sierra Research

More information

CapeSym, Inc. Radiation Detection Solutions

CapeSym, Inc. Radiation Detection Solutions ScintiClear Plug & Play Developer Kit ScintiClear Developer Kit Our developer kit is a plug-and-play high energy resolution gamma spectrometer ready to measure in less than 30 minutes after the box is

More information

The Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine!

The Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine! The Multi-Wiper HE High Energy Nuclear Medicine Well Counter The first multi-well counters designed specifically for Nuclear Medicine! * Comprehensive wipe testing with concise report in DPM * Available

More information

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output.

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output. www.raytest.com Choose your application of ß + RADIATION chromatography stand alone software controlled chemical purity HPLC PET GABI 2x2 Nal (Tl) 0 1V output PET GABI 2x2 Nal (Tl) Gina-PCcontrolled TLC

More information

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA The Underwater Spectrometric System Based on CZT Detector for Survey of the Bottom of MR Reactor Pool 13461 Victor Potapov, Alexey Safronov, Oleg Ivanov, Sergey Smirnov, Vyacheslav Stepanov National Research

More information

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA Testing and Performance Validation of a Sensitive Gamma Ray Camera Designed for Radiation Detection and Decommissioning Measurements in Nuclear Facilities- 13044 John A. Mason*, Richard Creed**, Marc R.

More information

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA Determination of Components of Fuel Matrix in Water and in Bottom Slimes in the MR Reactor Ponds in NRC Kurchatov Institute 14038 Alexey Stepanov *, Iurii Simirskii *, Ilya Semin *, Anatoly Volkovich *

More information

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC A. Specification Whole body counting method is used to detect the gamma rays emitted by radio nuclides,

More information

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution Chikkappa Udagani Abstract: This paper presents the precise method to estimate the dependence of linear and mass

More information

General Overview of Radiation Detection and Equipment

General Overview of Radiation Detection and Equipment www.inl.gov INL/MIS-11-22727 General Overview of Radiation Detection and Equipment International Nuclear Safeguards Policy and Information Analysis Course Monterey Institute of International Studies June

More information

"Neutron Flux Distribution"

Neutron Flux Distribution TECHNICAL UNIVERSITY DRESDEN Institute of Power Engineering Training Reactor Reactor Training Course Experiment "Neutron Flux Distribution" Instruction for Experiment Neutron Flux Distribution Content:

More information

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION OBJECTIVE The primary objective of this experiment is to use an NaI(Tl) detector, photomultiplier tube and multichannel analyzer software system

More information

EM 27/SUN Series. Innovation with Integrity. For Atmospheric Measurements FT-IR

EM 27/SUN Series. Innovation with Integrity. For Atmospheric Measurements FT-IR EM 27/SUN Series For Atmospheric Measurements Innovation with Integrity FT-IR The new EM27/SUN Series spectrometers represent FT-IR Remote Sensing analyzers dedicated for atmospheric measurements. They

More information

RADEAGLE. Next Generation Radioisotope Identification Device. Detection and Identification: Fast, Accurate and Easy

RADEAGLE. Next Generation Radioisotope Identification Device. Detection and Identification: Fast, Accurate and Easy RADEAGLE Next Generation Radioisotope Identification Device Detection and Identification: Fast, Accurate and Easy RADEAGLE RADEAGLE is a state-of-the-art handheld, radioisotope identification device (RIID)

More information

RMCC CANBERRA Latest developments

RMCC CANBERRA Latest developments RMCC -2015 CANBERRA Latest developments Daniel Obrecht International Sales Manager CANBERRA Worldwide Presence 50 years in business Over 1,000 employees 7 industrial sites Canada Sweden Germany Belgium

More information

IDENTIFICATION AND QUANTIFICATION OF RADIONUCLIDES IN HISTORICAL WASTE AT ANSTO

IDENTIFICATION AND QUANTIFICATION OF RADIONUCLIDES IN HISTORICAL WASTE AT ANSTO IDENTIFICATION AND QUANTIFICATION OF RADIONUCLIDES IN HISTORICAL WASTE AT ANSTO McOrist G D., Bowles C.J., Fernando K. and Wong R. Australian Nuclear Science and Technology Organisation Australia Abstract

More information

FoodScreen Radiological Food Screening System

FoodScreen Radiological Food Screening System Features Rapid screening of processed or raw food products for key 131I, 134 Cs and 137 Cs nuclides Clear, immediate indication if any nuclide-specific maximum permissible concentrations are exceeded Transportable

More information

Research Gamma Counter

Research Gamma Counter Research Gamma Counter Multi-Detector Gamma Counters High performance gamma counters for RIA and research applications Complete data reduction for all RIA, IRMA, Radio and Research assays Selectable dual

More information

Empowering water/wastewater network management with GIS

Empowering water/wastewater network management with GIS Empowering water/wastewater network management with GIS Ioannis Kavouras_GIS Manager Surveying Engineer, MSc, MBA The Company responsible for fresh water distribution & sanitation serving 1.500.000 citizens

More information

HEROICA: a test facility for the characterization of BEGe detectors for the GERDA experiment

HEROICA: a test facility for the characterization of BEGe detectors for the GERDA experiment Physikalisches Institut Kepler Center for Astro and Particle Physics : a test facility for the characterization of BEGe detectors for the GERDA experiment Raphael Falkenstein for the GERDA collaboration

More information

7 th International Summer School 2015, JRC Ispra: Operational Issues in Radioactive Waste Management and Nuclear Decommissioning

7 th International Summer School 2015, JRC Ispra: Operational Issues in Radioactive Waste Management and Nuclear Decommissioning 7 th International Summer School 2015, JRC Ispra: Operational Issues in Radioactive Waste Management and Nuclear Decommissioning Nucleonica: Nuclear Applications for Radioactive Waste Management and Decommissioning

More information

MAPPING OF DOSE-RATE OF GAMMA-IRRADIATION BY 137 Cs OVER THE EARTH SURFACE FOR THE TERRITORY OF RUSSIA

MAPPING OF DOSE-RATE OF GAMMA-IRRADIATION BY 137 Cs OVER THE EARTH SURFACE FOR THE TERRITORY OF RUSSIA MAPPING OF DOSE-RATE OF GAMMA-IRRADIATION BY 137 Cs OVER THE EARTH SURFACE FOR THE TERRITORY OF RUSSIA Yu.A.Izrael, E.V.Kvasnikova, I.M.Nazarov, A.N.Pegoev, E.D.Stukin Institute of Global Climate and Ecology,

More information

GAMMA RAY SPECTROSCOPY

GAMMA RAY SPECTROSCOPY GAMMA RAY SPECTROSCOPY Gamma Ray Spectroscopy 1 In this experiment you will use a sodium iodide (NaI) detector along with a multichannel analyzer (MCA) to measure gamma ray energies from energy level transitions

More information

8 th International Summer School 2016, JRC Ispra on Nuclear Decommissioning and Waste Management

8 th International Summer School 2016, JRC Ispra on Nuclear Decommissioning and Waste Management 8 th International Summer School 2016, JRC Ispra on Nuclear Decommissioning and Waste Management Nucleonica: Nuclear Applications for Radioactive Waste Management and Decommissioning cloud based nuclear

More information

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR Ensuring ultimate cleanliness for maximum adhesion Application Note Author John Seelenbinder Agilent Technologies,

More information

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ Design and Construction of a High Energy X-Ray R&D Facility, and the Development and Optimization of Real Time Radioisotopic Characterization of Remote Handled Waste at MeV Energies. S. Halliwell, V.J.Technologies

More information

A gamma-gamma coincidence spectrometer for nuclear attribution and safeguard applications

A gamma-gamma coincidence spectrometer for nuclear attribution and safeguard applications IAEA-CN-184/174 A gamma-gamma coincidence spectrometer for nuclear attribution and safeguard applications Weihua Zhang, Jing Yi, Pawel Mekarski and Kurt Ungar Radiation Protection Bureau of Health Canada,

More information

Shielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis

Shielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis Shielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis The shielded γ-ray spectrometer of Dr. Westmeier GmbH employs a NaI(Tl) or other scintillation detector with good resolution inside

More information

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219 REX Evaluation Guide American Micro Detection Systems Inc. 2800 March Lane, Suite 200 Stockton, CA 95219 I. INTRODUCTION REX (Real-time Elemental X-ray Fluorescence System) is the only instrument capable

More information

Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples

Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples Mashaba, Machel. 1*, Kotze, Deon. 2, Tshivhase, Victor.M. 1, Faanhof, Arnaud. 1, 2 1

More information

European Project Metrology for Radioactive Waste Management

European Project Metrology for Radioactive Waste Management European Project Metrology for Radioactive Waste Management Petr Kovar Czech Metrology Institute Okruzni 31 638 00, Brno, Czech republic pkovar@cmi.cz Jiri Suran Czech Metrology Institute Okruzni 31 638

More information

MSCL-S: MULTI-SENSOR CORE LOGGER NON-DESTRUCTIVE CONTINUOUS CORE SCANNING FOR INDUSTRY & RESEARCH

MSCL-S: MULTI-SENSOR CORE LOGGER NON-DESTRUCTIVE CONTINUOUS CORE SCANNING FOR INDUSTRY & RESEARCH MSCL-S: MULTI-SENSOR CORE LOGGER NON-DESTRUCTIVE CONTINUOUS CORE SCANNING FOR INDUSTRY & RESEARCH IF CORE S WORTH TAKING, IT S WORTH LOGGING AUTOMATED & FLEXIBLE CORE LOGGING & SCANNING The Geotek Standard

More information

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES V. MAIOROV, A. CIURAPINSKI, W. RAAB and V. JANSTA Safeguards Analytical Laboratory, International Atomic Energy

More information

XA TERRESTRIAL GAMMA DOSE RATE MAPS, THEIR COMPILATION AND VERIFICATION RADIOMETRIC MAP OF THE CZECH REPUBLIC

XA TERRESTRIAL GAMMA DOSE RATE MAPS, THEIR COMPILATION AND VERIFICATION RADIOMETRIC MAP OF THE CZECH REPUBLIC TERRESTRIAL GAMMA DOSE RATE MAPS, THEIR COMPILATION AND VERIFICATION RADIOMETRIC MAP OF THE CZECH REPUBLIC XA9745936 M. MATOLIN Faculty of Science, Charles University, Prague, Czech Republic Abstract Maps

More information

Analysis of natural radioactivity and artificial radionuclides in soil samples in the Najran region of Saudi Arabia

Analysis of natural radioactivity and artificial radionuclides in soil samples in the Najran region of Saudi Arabia Safety and Security Engineering V 675 Analysis of natural radioactivity and artificial radionuclides in soil samples in the Najran region of Saudi Arabia A. Al-Zahrany & K. S. Al-Mogabes Institute of Atomic

More information

Ringhals AB. Routines for whole body counting at Ringhals NPP

Ringhals AB. Routines for whole body counting at Ringhals NPP Routines for whole body counting at Ringhals NPP Structure Equipment - Quick Scan - Whole body counter Marie Carlson M.Sc. Radiology and Dosimetry Radiation Physicist and deputy RP Controller Routines

More information

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL A. Specification Gamma-spectrometry method is used to identify and determine the activity concentration

More information

RADIATION MONITORING NETWORKS and some results from the reactor accident in Fukushima

RADIATION MONITORING NETWORKS and some results from the reactor accident in Fukushima RADIATION MONITORING NETWORKS and some results from the reactor accident in Fukushima Sixth Annual Workshop on Radiation Measurement Cross Calibration Project June 13-15, 2011 Middle East Scientific Institute

More information

LS6500 Scintillation Counting Systems

LS6500 Scintillation Counting Systems LS6500 Scintillation Counting Systems Agenda LS6500 Concepts and Design H# Plus - The Basis of Advanced Technology Low Level Counting Alpha/Beta Discrimination LS6500 Concepts Give reproducible results

More information

Environmental Applications

Environmental Applications Environmental Applications Gamma ray Spectrometry Paul Nolan University of Liverpool Gamma ray spectrometry of environmental samples is a standard technique Germanium detector Programs available for spectrum

More information

SLAC Radioanalysis Laboratory

SLAC Radioanalysis Laboratory SLAC Radioanalysis Laboratory Henry Brogonia Dosimetry and Radiological Protection Group (DREP) DOE Environmental Radiation Protection Program Review (July 23-24, 2007) Radioanalysis Laboratory Mission

More information

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING W. Hennig 1, H. Tan 1, A. Fallu-Labruyere 1, W. K. Warburton 1, J. I. McIntyre 2, A. Gleyzer 3 XIA, LLC 1, Pacific Northwest National Laboratory

More information

RADIATION PROTECTION

RADIATION PROTECTION DEPARTMENT OF NUCLEAR TECHNOLOGY, FACULTY OF ENGINEERING CHULALONGKORN UNIVERSITY PHAYATHAI ROAD, BANGKOK 10330, THAILAND TEL: (662) 218-6772, (662) 218-6784. FAX: (662) 218-6770 E-mail: fnegbr@eng.chula.ac.th

More information

IEC Tritium Standard

IEC Tritium Standard detect and identify IEC 62303 Tritium Standard Dr. Alfred Klett Berthold Technologies, Bad Wildbad, Germany 21 st Annual Air Monitoring Users Group (AMUG) Meeting Palace Station Hotel, Las Vegas, Nevada,

More information

Information about the effects of the reactor disaster in Fukushima on the worldwide networked

Information about the effects of the reactor disaster in Fukushima on the worldwide networked We make radiation measureable! Information about the effects of the reactor disaster in Fukushima on the worldwide networked economy Detect radiation in a reliable way www.sea-duelmen.de The reactor disaster

More information

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION

More information

Advanced Gamma Spectroscopy

Advanced Gamma Spectroscopy Nuclear Division Scientech Advanced Gamma Spectroscopy Spin and Parity of ground state 18 Sb124 20.2 m IT 26.0, e γ 10.9D,e 5+ 1.6m IT 10.9,e β 1.2,... γ 602.7,645.8 498.4,... 3 60.20 d β.61, 2.301, γ

More information

Pulsar. Delivering NMR to your benchtop

Pulsar. Delivering NMR to your benchtop Pulsar NMR Delivering NMR to your benchtop Pulsar TM NMR for your laboratory The Pulsar TM NMR spectrometer from Oxford Instruments delivers affordable, high performance NMR spectroscopy into the laboratory

More information

Applied Nuclear Science Educational, Training & Simulation Systems

Applied Nuclear Science Educational, Training & Simulation Systems WWW.NATS-USA.COM Applied Nuclear Science Educational, Training & Simulation Systems North American Technical Services Bridging Technology With The Latest in Radiation Detection Systems & Training Solutions

More information

On-line XRF analysis of multiple elements in liquid process streams C-QUAND

On-line XRF analysis of multiple elements in liquid process streams C-QUAND An ideal tool for multiple element analysis using on-line XRF technology, from low ppm to percentage levels C-QUAND On-line XRF analysis of multiple elements in liquid process streams Introduction The

More information

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools 10th Nuclear Science Training Course with NUCLEONICA, Cesme, Turkey, 8-10 October, 2008 1 Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools A.N. Berlizov ITU - Institute for Transuranium

More information

ORTEC was founded in 1960 by researchers from Oak Ridge National Labs to commercialize charged particle detectors

ORTEC was founded in 1960 by researchers from Oak Ridge National Labs to commercialize charged particle detectors DAVIDE SACCHI 1 ORTEC Overview ORTEC was founded in 1960 by researchers from Oak Ridge National Labs to commercialize charged particle detectors Headquarters: Oak Ridge, TN with global sales and service

More information

OXEA - Online Elemental Analyzer

OXEA - Online Elemental Analyzer 02 25 08 OXEA - Online Elemental Analyzer OXEA (Online X-ray Elemental Analyzer) is based on the X-ray fluorescence technology (XRF) which is well known in the laboratory field. With the aid of a patented

More information

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN 316 Effective atomic number of composite materials by Compton scattering - nondestructive evaluation method Kiran K U a, Ravindraswami K b, Eshwarappa K M a and Somashekarappa H M c* a Government Science

More information

Design and production of Scintillation Detectors

Design and production of Scintillation Detectors Design and production of Scintillation Detectors Components for nuclear radiation detectors Fields of application: * Medicine * Industry * Science * Security Scintillation Detectors : Instruments using

More information

New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist

New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist Genie-2000 Latest Features Cascade Summing Correction LACE (Line Activity Consistency Evaluator) Interactive Nuclide

More information

Terrestrial gamma dose rates along one of the coastal highways in Sri Lanka

Terrestrial gamma dose rates along one of the coastal highways in Sri Lanka Sri Lankan Journal of Physics, Vol. 2 (21) 1-6 Institute of Physics - Sri Lanka Terrestrial gamma dose rates along one of the coastal highways in Sri Lanka C.S. Sumithrarachchi and R. Hewamanna * Department

More information

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect Microscanner D-Series The Only Certified Accurate Surface Instruments in the World A MUST FOR ISO 9001 ISO 9002 ISO 9003 TRACEABILITY PROGRAMS Common Surface Measurement Errors D501 and D501-RS Microscanner

More information

Alpha-Energies of different sources with Multi Channel Analyzer

Alpha-Energies of different sources with Multi Channel Analyzer Physical Structure of Matter Radioactivity Alpha-Energies of different sources with Multi Channel Analyzer What you can learn about Decay series Radioactive equilibrium Isotopic properties Decay energy

More information

Finnigan LCQ Advantage MAX

Finnigan LCQ Advantage MAX www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer

More information

A Digital Method for Dead Time Compensation in Nuclear Spectroscopy

A Digital Method for Dead Time Compensation in Nuclear Spectroscopy A Digital Method for Dead Time Compensation in Nuclear Spectroscopy Keyser, Ronald M., Gedcke, Dale A., Upp, Daniel L., Twomey, Timothy R., and Bingham, Russell D. ORTEC, PerkinElmer Instruments, Inc.

More information