1 Design and production of Scintillation Detectors Components for nuclear radiation detectors Fields of application: * Medicine * Industry * Science * Security
2 Scintillation Detectors : Instruments using inorganic scintillation crystals or organic scintillators (plastics/ liquids) Radiation + Crystal -> Light -> Electrical signal SCIONIX : Designs and manufactures scintillation detectors and - probes for application in Medicine, Science, Security and Industry Emphasis is on dedicated instruments, often custom made.
3 History of SCIONIX - Expertise of former HARSHAW personnel has been the basis of SCIONIX Holland HARSHAW HOLLAND active in above field SINCE 1960's HARSHAW crystal products sold to Saint Gobain Holland plant closed SCIONIX Holland founded using experience and know-how in manufacture of detectors in Holland. Over the last 20 years the SCIONIX name has been established in the scintillation detection community.
4 Scintillation crystal is important component * Inorganic synthetic crystal * Grown from solution or melt in furnace * diameters from 1 cm to 75 cm diameter * (depending on material and application) Examples of Materials used : NaI(Tl), CsI(Tl), CsI(Na), CaF 2 (Eu), 6-LiI(Eu), BGO, CdWO 4, YAP:Ce, PWO, LaCl 3, CeBr 3 ; each type different characteristics. NaI(Tl) These materials in rough form (ingots, blocks) procured by SCIONIX from a large number of outside suppliers for cutting, polishing, encapsulation or further processing. CsI(Tl) CdWO4
5 Product Range - Encapsulated scintillation crystals with optical windows - Scintillation detectors equiped with light readout devices (Photomultiplier Tube, photodiode or eq.) - Scintillation probes with front-end electronics - Detectors with HV supply and advanced hybrid electronics (own development) SCIONIX DOES NOT supply : - Complete Health Physics Instrumentation systems - Monitors or digital processing electronics 65 % of products are manufactured for OEM customers
6
7 Some Milestones : 1993 CHARISSA Array (Univ. Birmingham) kg NaI(Tl) detector system supplied to INFN FRASCATI 1996 SCIONIX become the main supplier to the IAEA Nuclear Safe guard inspectors 1997 Large ORNL Anti-Compton suppression Array delivered CsI(Tl) elements (3 tons) to the CHIMERA experiment delivered ( > 3 tons) scintillation element array for Integral (ESA) satellite supplied Large BaF2 crystal ball ( 500 kg) at LANL supplied by SCIONIX.
8 BGO shields project for security applications (LLNL) 2003 SCIONIX becomes contract partner for CMS project with CERN in cooperation with BTCP 2004 SCIONIX key supplier for most important hand-held instrumentation companies 2005 Developments in neutron detectors with 6-Li crystals leads to new generation of instruments for security applications (border control) 2006 New generation of liquid scintillator cells for neutron / gamma detection 2008 More emphasis on security applications, smaller designs 2009 Development of devices with advanced crystals and readout 2012 CeBr 3 detectors, High flash point liquids SrI 2 (Eu), CLYC KEYWORDS - Flexibility - Expert Customer support - Solution provided - Dedicated applications - Business partnership
9 Capabilities Manufacturing - Cutting and processing of various scintillation materials - Dry room area of < 3 % RH for manufacturing of large assemblies (gamma cameras) - Encapsulation facilities for hygroscopic scintillation crystals - Manufacturing facilities for metal housings and other hardware.
10 Quality control and testing - Characterization of scintillation materials - Advanced measurements on scintillators and light detection techniques - Climate chamber for environmental tests and temperature cycling - Vibration and shock equipment at external facility - Computer controlled X-Y translation tables for homogeneity tests of large area detectors. - Full range of nuclear radiation detection instrumentation - Low background chamber with HPGe detector for material characterization.
11 Sales and marketing - SCIONIX products are often sold via a world-wide agent/distributor network. Some countries are handled direct. - Technical support is usually offered directly from the factory Some products that contain SCIONIX scintillation detectors - Hand held Nuclide Identification instruments - Density measurement equipment on dredging ships - Afterloading equipment for radiotherapy (brachytherapy) - Regional perfusion equipment - Intra-operative probes - Bone densitometers - Gamma cameras - X-ray diffraction equipment
12 Examples of Products in several Ranges Open window crystal assemblies CsI(Tl) pixels NaI(Tl) C-Styles CsI(Tl) BaF2
13 Detectors with PMT Standard B-styles OFHC NaI(Tl) Well detector Hexagonal BaF2 detector BGO Well det.
14 Detectors with advanced electronics Pen-type detector Stabilised probes with HV and dedicated amplifiers Challenges : - Low power - X-proof sometimes - Rugged
15 Detectors with semiconductor readout Heavy ion detector and identification Challenges : Noise, compactness
16 Security Applications : - dirty bombs - Special Nuclear materials (WGPu, HEU) Neutron detection Challenges : - Better and faster indentification - Neutron gamma discrimination - Better energy resolution - Compact, robust
17 Large inorganic scintillation detectors 4 x4 x16 detectors with Portal monitors Integrated HV supply 2 x4 x16 NaI(Tl) detector
18 Underwater Shipping Container Personal dosimeter
19 Medical Applications Safety in afterloading devices (high dose rates) Gamma camera crystals Bone densitometry Challenges : - High rates - Energy resolution
20 Scrap Monitoring Sometimes metal scrap is contamined with Cs-137 or Co-60 from radio therapy devices Organic scintillators are often used but these are not nuclide specific Challenges : Energy resolution needed, cost
21 Recent sensor developments to achieve our goals : 1. Better crystals (more Light output, better proportionality) 2. Better PMTs (higher QE better statistics) 3. Alternative readout methods (silicon PMTs, Silicon drift detectors) Developments are going fast and it is mandatory to explore the opportunities these new materials and sensors offer. Direct connection of detectors to USB
22 CeBr x 25.4 mm 137-Cs counts per Channel Energy (arb. units) CeBr kev Fast decay (15 ns) Density 5.2 g / cc Brighter scintillators Higher QE PMTs Silicon Photomultipliers Arrays of self Quenched APDs in geiger mode. - Large gains - Possible inexpensive - Higher QE than PMTs
23 Close cooperation with the end user on technical level is very important for a successful project
Unit 2. Instrumentation. Experts Teaching from Practical Experience
Unit 2 Instrumentation Experts Teaching from Practical Experience Gas-Filled Detectors Gas-filled detectors measure the charge released when radiation interacts with the gas Three types: Ion Chambers,
More informationSCINTILLATION DETECTORS AND PM TUBES
SCINTILLATION DETECTORS AND PM TUBES General Characteristics Introduction Luminescence Light emission without heat generation Scintillation Luminescence by radiation Scintillation detector Radiation detector
More informationIntroduction to Radiation Monitoring
Introduction to Radiation Monitoring Iain Darby Honorary Research Fellow, University of Glasgow iain.darby@glasgow.ac.uk https://at.linkedin.com/in/idarby https://www.facebook.com/iain.darby.662 Outline
More informationIdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications
fire IdentiFINDER Digital Hand Held Spectrometer & The world s smallest spectrometer and dose rate meter designed for portable applications. safety security identifinder - CH (yellow) CZT and neutron detector
More informationRADEAGLE. Next Generation Radioisotope Identification Device. Detection and Identification: Fast, Accurate and Easy
RADEAGLE Next Generation Radioisotope Identification Device Detection and Identification: Fast, Accurate and Easy RADEAGLE RADEAGLE is a state-of-the-art handheld, radioisotope identification device (RIID)
More informationRADEAGLET. Lightweight Handheld Radioisotope Identification Device
RADEAGLET Lightweight Handheld Radioisotope Identification Device Weighing Only 900 grams, the RADEAGLET is the Lightest HH-RIID in the world! The Perfect Instrument for First Responders Who Need to Wear
More informationDetector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples
Aim of this tal Detector technology WMIC Educational Program Nuclear Imaging World Molecular Imaging Congress, Dublin, Ireland, Sep 5-8, 202 You can now the name of a bird in all the languages of the world,
More information1 of :32
Home Page Products Price List Links & PDFs DISCONTINUED: SEE GAMMA-RAD Gamma Ray & X-Ray Spectroscopy System Hand-Held, High Efficiency NaI(Tl) Detector The GAMMA-8000 is a powerful, portable instrument
More informationNew Scintillators for the Border Monitoring Equipment
New Scintillators for the Border Monitoring Equipment M. Moszynski a a Soltan Institute for Nuclear Studies, PL 05-400 Otwock-Swierk, Poland Performance of new scintillators characterized by a high energy
More information05 - Scintillation detectors
05 - Scintillation detectors Jaroslav Adam Czech Technical University in Prague Version 2 Jaroslav Adam (CTU, Prague) DPD_05, Scintillation detectors Version 2 1 / 39 Scintillation detector principles
More informationLawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory
Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory Title Labr3:Ce scintillators for gamma ray spectroscopy Permalink https://escholarship.org/uc/item/38f0c7zv Authors Shah, K.S.
More informationModular Survey Spectrometer and Compton Imager
1 Modular Survey Spectrometer and Compton Imager Audrey MacLeod Ionizing Radiation Standards Measurement Science and Standards National Research Council Canada On behalf of the SCoTSS collaboration (Silicon
More informationRadiation Detection and Measurement
Radiation Detection and Measurement Third Edition Glenn F. Knoll Professor of Nuclear Engineering and Radiological Sciences University of Michigan Ann Arbor, Michigan John Wiley & Sons, Inc. New York/Chichester/Weinheim/Brisbane/Toronto/Singapore
More informationA new scintillator detector for nuclear physics experiments: the CLYC scintillator
A new scintillator detector for nuclear physics experiments: the CLYC scintillator Franco Camera 1 and Agnese Giaz 2 1 Università di Milano and INFN sezione di Milano 2 INFN sezione di Milano (current
More informationContents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung
Contents Marcel MiGLiERiNi Nuclear Medicine, Radiology and Their Metrological Aspects. Radiation in Medicine. Dosimetry 4. Diagnostics & Therapy 5. Accelerators in Medicine 6. Therapy Planning 7. Nuclear
More informationRadiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors
Radiation Detectors 1 How do we detect ionizing radiation? Indirectly, by its effects as it traverses matter? What are these effects? Ionization and excitation of the atoms and molecules Heat 2 Types of
More informationRadiation Detection and Measurement
Radiation Detection and Measurement Fourth Edition Glenn F. Knoll Professor Emeritus of Nuclear Engineering and Radiological Sciences University of Michigan Ann Arbor, Michigan WILEY John Wiley & Sons,
More informationRadionuclide Imaging MII Detection of Nuclear Emission
Radionuclide Imaging MII 3073 Detection of Nuclear Emission Nuclear radiation detectors Detectors that are commonly used in nuclear medicine: 1. Gas-filled detectors 2. Scintillation detectors 3. Semiconductor
More informationRADIATION DETECTION AND MEASUREMENT
RADIATION DETECTION AND MEASUREMENT SECOND EDITION GLENN F. KNOLL Professor of Nuclear Engineering The University of Michigan Ann Arbor, Michigan WILEY JOHN WILEY & SONS New York Chichester Brisbane Toronto
More informationRadiation Detection and Measurement
Radiation Detection and Measurement June 2008 Tom Lewellen Tkldog@u.washington.edu Types of radiation relevant to Nuclear Medicine Particle Symbol Mass (MeV/c 2 ) Charge Electron e-,! - 0.511-1 Positron
More informationChapter 4 Scintillation Detectors
Med Phys 4RA3, 4RB3/6R03 Radioisotopes and Radiation Methodology 4-1 4.1. Basic principle of the scintillator Chapter 4 Scintillation Detectors Scintillator Light sensor Ionizing radiation Light (visible,
More informationDual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT
Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT Dr. Andrea Fabbri, University of Rome Roma Tre I.N.F.N. (National Institue of Nuclear Physics) γ-ray imaging with scintillator and PSPMT γ-ray
More informationSCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator
88 The 1 st NPRU Academic Conference SCI-O11 Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator P. Limkitjaroenporn and W.Chewpraditkul Radiation Physics Laboratory,
More informationGamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector
Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector C. Fiorini, member, IEEE, A. Gola, M. Zanchi, A. Longoni, P. Lechner, H. Soltau, L. Strüder Abstract In this work
More informationCompton suppression spectrometry
Compton suppression spectrometry In gamma ray spectrometry performed with High-purity Germanium detectors (HpGe), the detection of low intensity gamma ray lines is complicated by the presence of Compton
More informationScintillation Detectors
Scintillation Detectors J.L. Tain Jose.Luis.Tain@ific.uv.es http://ific.uv.es/gamma/ Instituto de Física Corpuscular C.S.I.C - Univ. Valencia Scintillation detector: SCINTILLATION MATERIAL LIGHT-GUIDE
More informationMeasurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search
Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search Hanwool Joo on behalf of the KIMS-NaI collaboration Department of Physics and Astronomy, 1 Gwanak-ro, Gwanak-gu, Seoul
More informationNon-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277
Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277 D. Nakazawa and F. Bronson Canberra Industries Inc., 800 Research Parkway, Meriden, CT, 06450, USA. ABSTRACT
More information28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING
DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING W. Hennig 1, H. Tan 1, A. Fallu-Labruyere 1, W. K. Warburton 1, J. I. McIntyre 2, A. Gleyzer 3 XIA, LLC 1, Pacific Northwest National Laboratory
More informationRadiation Detection. 15 th Annual OSC Readiness Training Program.
Radiation Detection 15 th Annual OSC Readiness Training Program www.oscreadiness.org GM Detectors 15 th Annual OSC Readiness Training Program www.oscreadiness.org 1 A closer look 15 th Annual OSC Readiness
More informationWiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher
Wiper Gold Edition Premium Wipe Test Counter Setting the bar higher Software - Simplicity, Re-defined Load your wipe into the well and press the button. Your wipe is counted and automatically converted
More informationThe SpecMAT project: An array of gamma-ray detectors around an active gas target
The SpecMAT project: An array of gamma-ray detectors around an active gas target J. A. Swartz (KU Leuven- IKS) ATTPC workshop Michigan State University 19/05/2015 Contents 1. The SpecMAT Project 2. Scintillators
More informationA NEW GENERATION OF GAMMA-RAY TELESCOPE
A NEW GENERATION OF GAMMA-RAY TELESCOPE Aleksandar GOSTOJIĆ CSNSM, Orsay, France 11 th Russbach School on Nuclear Astrophysics, March 2014. Introduction: Gamma-ray instruments GROUND BASED: ENERGY HIGHER
More informationarxiv: v2 [physics.ins-det] 8 Feb 2013
Preprint typeset in JINST style - HYPER VERSION arxiv:1302.0278v2 [physics.ins-det] 8 Feb 2013 Investigation of gamma ray detection performance of thin LFS scintillator with MAPD readout E.Guliyev a, F.Ahmadov
More informationFast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner
Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner J.E. Eberhardt, A.J. McEwan, D. Milinkovic, V. Sharp, * and J.R. Tickner CSIRO Minerals, Private Mail Bag 5, Menai NSW 2234 Australia
More informationPrecision Crystal Calorimeters in High Energy Physics: Past, Present and Future
June 5, 2006 1 International Conference on Calorimetry in Particle Physics, Chicago, USA Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future Ren-Yuan Zhu California Institute
More informationRadioactivity. Lecture 6 Detectors and Instrumentation
Radioactivity Lecture 6 Detectors and Instrumentation The human organs Neither humans nor animals have an organ for detecting radiation from radioactive decay! We can not hear it, smell it, feel it or
More informationGeneral Overview of Radiation Detection and Equipment
www.inl.gov INL/MIS-11-22727 General Overview of Radiation Detection and Equipment International Nuclear Safeguards Policy and Information Analysis Course Monterey Institute of International Studies June
More informationPrecision Crystal Calorimetry in High Energy Physics
Precision Crystal Calorimetry in High Energy Physics Ren Yuan Zhu California Institute of Technology August 13, 2008 Hard X Ray, Gamma Ray, and Neutron Detector Physics X, SPIE 2008, San Diego Why Crystal
More informationIEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST 2008 2425 Optical and Scintillation Properties of Inorganic Scintillators in High Energy Physics Rihua Mao, Member, IEEE, Liyuan Zhang, Member,
More informationV. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber
CYRIC Annual Report 2001 V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber Kawata N. Baba M. Kato M.*, Miura T.**, and Yamadera A.***, Cyclotron and Radioisotope Center, Tohoku
More informationStudies of Hadron Calorimeter
Studies of Hadron Calorimeter Zhigang Wang Institute of High Energy Physics 2012.10.17 in IHEP Outline 1,The Dark Matter Calorimeter 2,The Hadron Calorimeter(HCAL) 3, Summary 1,Dark Matter Calorimeter
More informationFactors Affecting Detector Performance Goals and Alternative Photo-detectors
XENON Experiment - SAGENAP Factors Affecting Detector Performance Goals and Alternative Photo-detectors Department of Physics Brown University Source at http://gaitskell.brown.edu Gaitskell Review WIMP
More information29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies
CHARACTERIZATION OF PHOSWICH WELL DETECTORS FOR RADIOXENON MONITORING Wolfgang Hennig 1, Hui Tan 1, William K. Warburton 1, Anthony Fallu-Labruyere 1, Konstantin Sabourov 1, Justin I. McIntyre 2, Matthew
More informationRecent advances and future perspectives of gamma imagers for scintimammography
3rd International Conference on Imaging Technologies in Biomedical Sciences: ITBS2005 Innovation in Nuclear and Radiological Imaging: From Basic Research to Clinical Application Milos Conference Center,
More informationPolaris 3-D CdZnTe (CZT) Gamma-Ray Imaging Spectrometers
Polaris 3-D CdZnTe (CZT) Gamma-Ray Imaging Spectrometers Zhong He ISOE-ALARA Symposium, January 12, 2015 Acknowledgements: DOD, DOE and DHS John M. Palms Outstanding Innovation Began in early 1960s Thank
More informationChapter 6: Basic radiation detectors
Chapter 6: Basic radiation detectors Set of 60 slides based on the chapter authored by C.W.E. VAN EIJK Faculty of Applied Sciences, Delft University of Technology, Delft, Netherlands of the publication
More informationCVD Diamond History Introduction to DDL Properties of Diamond DDL Proprietary Contact Technology Detector Applications BDD Sensors
Diamond Detectors CVD Diamond History Introduction to DDL Properties of Diamond DDL Proprietary Contact Technology Detector Applications BDD Sensors Kevin Oliver CEO Alex Brown Sales & Marketing 20 May,
More informationUltra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals
Ultra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals Roberto Pani INFN and Sapienza - University of Rome, Italy On behalf of ECORAD Collaboration Cinti
More informationChemical Engineering 412
Chemical Engineering 412 Introductory Nuclear Engineering Lecture 26 Radiation Detection & Measurement II Spiritual Thought 2 I would not hold the position in the Church I hold today had I not followed
More informationOPPORTUNITY TO JOIN IEEE AND NPSS
OPPORTUNITY TO JOIN IEEE AND NPSS If you are NOT an IEEE Member, IEEE & NPSS offers you a FREE: Half-year membership in IEEE (value= ~$80)* Half-year membership in NPSS (value= ~$13)* Half-year subscription
More informationCOMPARISON OF PERSONNEL RADIATION MONITORING DOSIMETERS DESIGNED FOR MEDICAL FIELD
COMPARISON OF PERSONNEL RADIATION MONITORING DOSIMETERS DESIGNED FOR MEDICAL FIELD Kirill SKOVORODKO, Birute GRICIENE, Milda PETKELYTE Radiation Protection Division, Vilnius University Hospital Santaros
More informationFissile material experiments at the Device Assembly Facility
Fissile material experiments at the Device Assembly Facility CVT Workshop October 20, 2016 Michael Hamel 1, Pete Chapman 2, Michael Streicher 1 1 University of Michigan 2 North Carolina State University
More informationScintillation Detectors
Radiation Measurement Systems Scintillation Detectors Ho Kyung Kim Pusan National University Scintillation detector = scintillator + light sensor Scintillators Inorganic alkali halide crystals Best light
More informationRadiation Protection & Radiation Therapy
Radiation Protection & Radiation Therapy For Medical Students Professor of Medical Physics Radiation Units Activity Number disintegrations per second (Curie, Becquerel) Exposure (Roentgen, C/kg) Absorbed
More informationDetector R&D in KAPAC
Detector R&D in KAPAC Hiroyasu Tajima Stanford Linear Accelerator Center Kavli Institute for Particle Astrophysics and Cosmology Outline Compton Camera SOI detector Scintillator Polarimeter Cherenkov Camera
More informationCapeSym, Inc. Radiation Detection Solutions
ScintiClear Plug & Play Developer Kit ScintiClear Developer Kit Our developer kit is a plug-and-play high energy resolution gamma spectrometer ready to measure in less than 30 minutes after the box is
More informationA Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring
A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring 1 Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education Department of Engineering
More informationISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.
PIXEL 2000 International Workshop on Semiconductor Pixel Detectors for Particles and X-Rays Genova - Porto Antico - Magazzini del Cotone (Sala Libeccio) June 5-8, 2000 ISPA-Tubes with YAP:Ce Active Windows
More informationLight yield non-proportionality and intrinsic energy resolution of doped CsI scintillators
NUKLEONIKA 2008;53(2):51 56 ORIGINAL PAPER Light yield non-proportionality and intrinsic energy resolution of doped CsI scintillators Weerapong Chewpraditkul, Lukasz Swiderski, Marek Moszynski Abstract.
More informationɣ-radiochromatography
nuclear instruments Kapitel_y_Graphy.indd 1 19.08.09 10:27 n u c l e a r i n s t r u m e n t s Index HPLC-detectors TLC-detectors GABI* analog output GABI* digital output to PC minigita*, 1 trace scanner
More informationPrecision Crystal Calorimeters in High Energy Physics: Past, Present and Future
April 4, 2006 1 International Symposium on Detector Development, SLAC, USA Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future Ren-Yuan Zhu California Institute of Technology
More informationTECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL
NUCLE A R FORENSIC S INTERN ATION A L TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL This document was designed
More informationReliability and Traceability in Radiation Calibration
Reliability and Traceability in Calibration Sadao Nakashima Teruo Ebato 1. Introduction Fuji Electric has a successful history of delivering radiation measuring equipment used in the controlled areas of
More informationAlpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce
Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce F.C.L. Crespi 1,2, F.Camera 1,2, N. Blasi 2, A.Bracco 1,2, S. Brambilla 2, B. Million 2, R. Nicolini 1,2, L.Pellegri 1, S. Riboldi
More informationRadiation Dose, Biology & Risk
ENGG 167 MEDICAL IMAGING Lecture 2: Sept. 27 Radiation Dosimetry & Risk References: The Essential Physics of Medical Imaging, Bushberg et al, 2 nd ed. Radiation Detection and Measurement, Knoll, 2 nd Ed.
More informationLarge Size LYSO Crystals for Future High Energy Physics Experiments
Large Size LYSO Crystals for Future High Energy Physics Experiments Jianming Chen, Liyuan Zhang, Ren-Yuan Zhu California Institute of Technology October 18, 2004 IEEE NSS04, Rome 1 Scintillating Crystals
More informationNon-proportionality of organic scintillators and BGO
Winston-Salem June 4, 2007 Non-proportionality of organic scintillators and BGO A. Nassalski, M. Moszyński, A. Syntfeld-Każuch, Ł. Świderski, T. Szczęśniak. The Soltan Institute for Nuclear Studies, PL
More informationQuality Assurance. Purity control. Polycrystalline Ingots
Quality Assurance Purity control Polycrystalline Ingots 1 Gamma Spectrometry Nuclide Identification Detection of Impurity Traces 1.1 Nuclides Notation: Atomic Mass Atomic Number Element Neutron Atomic
More informationCompton Camera. Compton Camera
Diagnostic Imaging II Student Project Compton Camera Ting-Tung Chang Introduction The Compton camera operates by exploiting the Compton Effect. It uses the kinematics of Compton scattering to contract
More informationIPNDV Working Group 3: Technical Challenges and Solutions Nuclear Material (3) Technology Data Sheet
Nuclear Material (NM) Technology Name: Gamma-Ray Imaging Physical Principle/Methodology of Technology: Gamma-ray imaging provides the location and shape information of gamma-ray emitting radionuclides.
More informationPulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging
Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging P A O L O B E N N A T I I N F N R O M A T R E E D E M O M P H D S C H O O L, R O M A T R E U N I V E R S I T Y P
More informationGM Pancake Probe Victoreen Model D
Radiation Safety RS GM Pancake Probe Victoreen Model 489-110D! All purpose GM Pancake Probe detects alpha, beta, gamma, and x-ray radiations! Used in nuclear medicine, diagnostic x-ray, and geological
More informationDetectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors
1 Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors C. Fiorini, A. Longoni, F. Perotti, C. Labanti, E. Rossi, P. Lechner,
More informationLarge volume LaBr 3 :Ce detectors and HECTOR +
Large volume LaBr 3 :Ce detectors and HECTOR + F. Camera University of Milano INFN sez. of Milano Outline: - Recent results in R&D with large volume 3.5 x8 LaBr 3 :Ce - Scientific Activity in Milano with
More informationDetector R&D at KIPAC. Hiro Tajima Kavli InStitute of Particle Astrophysics and Cosmology
Detector R&D at KIPAC Hiro Tajima Kavli InStitute of Particle Astrophysics and Cosmology Detector R&D Overview Si detector ASIC Integration GLAST GeV Gamma-ray Observatory ASIC DAQ Next generation X-ray
More informationDevelopment of a 3D-Imaging Calorimeter in LaBr 3 for Gamma-Ray Space Astronomy
Development of a 3D-Imaging Calorimeter in LaBr 3 for Gamma-Ray Space Astronomy Aleksandar GOSTOJIĆ CSNSM, Orsay, France 7 th New Developmeants In Photodetection, Tours, France, 2014 Introduction: Gamma-ray
More informationMEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah
MEDICAL EQUIPMENT: NUCLEAR MEDICINE Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook Introduction to Medical Imaging: Physics, Engineering and Clinical Applications, by Nadine Barrie Smith
More informationEEE4106Z Radiation Interactions & Detection
EEE4106Z Radiation Interactions & Detection 2. Radiation Detection Dr. Steve Peterson 5.14 RW James Department of Physics University of Cape Town steve.peterson@uct.ac.za May 06, 2015 EEE4106Z :: Radiation
More informationApplied Nuclear Science Educational, Training & Simulation Systems
WWW.NATS-USA.COM Applied Nuclear Science Educational, Training & Simulation Systems North American Technical Services Bridging Technology with the Latest in Radiation Detection Systems The Center For Innovative
More informationHigh-Sensitivity Gamma-Ray Imaging With Double Sided Strip Detectors
High-Sensitivity Gamma-Ray Imaging With Double Sided Strip Detectors Thomas Niedermayr, Morgan Burks, Lucian Mihailescu, Karl Nelson, David Lange, John Valentine, Kai Vetter Lawrence Livermore National
More informationSurvey of the performance of scintillation materials at low temperatures
Survey of the performance of scintillation materials at low temperatures Biswas Sharma University of Tennessee, Knoxville 4/5/2017 Particle Physics and Astro-Cosmology Seminar 1 Motivation Versatility
More informationPerformance of the Gamma-ray Imaging Detector with Micro-TPC
Performance of the Gamma-ray Imaging Detector with Micro-TPC Cosmic-Ray Group Dept. of Physics, Graduate School of Science, Kyoto University R.Orito Orito,H.Kubo,K.,H.Kubo,K.Miuchi,T.Nagayoshi, A.Takada,A.Takeda,T.Tanimori
More informationChapter Seven (Nuclear Detectors)
Al-Mustansiriyah University College of Science Physics Department Fourth Grade Nuclear Physics Dr. Ali A. Ridha Chapter Seven (Nuclear Detectors) Ionizing radiation is rarely detected directly. Instead,
More informationMeasurement of Tritium in Helium
detect and identify Measurement of Tritium in Helium Dr. Alfred Klett Berthold Technologies, Bad Wildbad, Germany 22 nd Annual Air Monitoring Users Group (AMUG) Meeting Palace Station Hotel, Las Vegas,
More informationWM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA
Experimental Comparison between High Purity Germanium and Scintillator Detectors for Determining Burnup, Cooling Time and Decay Heat of Used Nuclear Fuel - 14488 Peter Jansson *, Sophie Grape *, Stephen
More informationMeasurement of 39 Ar in Underground Argon for Dark Matter Experiments
Measurement of 39 Ar in Underground Argon for Dark Matter Experiments Jingke Xu Princeton University June 7 th, 2013 1 Evidences for Dark Matter Rotation Curve Gravitational Lensing CMB Power Spectrum
More informationSample Spectroscopy System Hardware
Semiconductor Detectors vs. Scintillator+PMT Detectors Semiconductors are emerging technology - Scint.PMT systems relatively unchanged in 50 years. NaI(Tl) excellent for single-photon, new scintillation
More informationMeasuring Radiation: An Introductory Discussion
Measuring Radiation: An Introductory Discussion What is radiation? How is it detected? How does it interact with matter? How is a radiation detector designed for my application? Saint-Gobain Crystals CRYSTALS
More informationNew perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors
New perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors Jean-Marc Dinten, Jean-Louis Amans, Loïck Verger, Olivier Peyret CEA-LETI, MINATEC, Recherche
More informationDETECTORS. I. Charged Particle Detectors
DETECTORS I. Charged Particle Detectors A. Scintillators B. Gas Detectors 1. Ionization Chambers 2. Proportional Counters 3. Avalanche detectors 4. Geiger-Muller counters 5. Spark detectors C. Solid State
More informationNGN PhD Studentship Proposal
NGN PhD Studentship Proposal Note that proposals will be assessed against both the quality of the scientific content and of the proposed training experience. Proposed supervisors (lead first) Dr Laura
More informationApplication of Nuclear Physics
Application of Nuclear Physics Frontier of gamma-ray spectroscopy 0.1 IR visible light UV soft X-ray X-ray hard X-ray gamma-ray 1 10 100 1e3 1e4 1e5 1e6 energy [ev] Photoelectric effect e - Compton scattering
More informationAlpha particle scintillation detector based on micro pixel avalanche photodiode and LYSO crystal
Alpha particle scintillation detector based on micro pixel avalanche photodiode and LYSO crystal G.S. Ahmadov, F.I. Ahmadov Institute of Radiation Problems of ANAS, Baku, Azerbaijan C. Granja, S. Pospíšil
More informationDirect WIMP Detection in Double-Phase Xenon TPCs
Outline PMTs in the XENON dark matter experiment XENON100 and the weekly gain calibration XENON1T and candidates for the light sensors Tests of Hamamatsu R11410 2 Direct WIMP Detection in Double-Phase
More information2010 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies
DESIGN AND MODELING OF A COMPTON-SUPPRESSED PHOSWICH DETECTOR FOR RADIOXENON MONITORING Abi T. Farsoni and David M. Hamby Oregon State University Sponsored by the National Nuclear Security Administration
More informationDesign of a Lanthanum Bromide Detector for TOF PET
Design of a Lanthanum Bromide Detector for TOF PET A. Kuhn, S. Surti, Member, IEEE, J. S. Karp, Senior Member, IEEE, P. S. Raby, K. S. Shah, A. E. Perkins, Member, IEEE, G. Muehllehner, Fellow Member,
More informationThe NaI:Tl and CsI:Tl crystals for effective detection of X-rays and low energy charged particles
The NaI:Tl and CsI:Tl crystals for effective detection of X-rays and low energy charged particles Alexander M. Kudin Institute for Scintillation Materials NAS of Ukraine National University of Civil Protection
More informationCompton Camera with PositionSensitive Silicon Detectors
University of Ljubljana Faculty of mathematics and physics Andrej Studen Compton Camera with PositionSensitive Silicon Detectors Doctoral thesis Supervisor: Professor Marko Mikuž Outline: Motivation Basic
More informationProspects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET
Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET, 28-Feb-2012, ICTR-PHE, Geneva, Switzerland 1 Time-of-flight PET Colon cancer, left upper quadrant peritoneal node
More information