CATALOG OR PART NUMBER SX SX18 4 SX20 5 SX20 SAMPLE SX20-4 SX SX21 5 SX21 SAMPLE SX22 5 SX22 SAMPLE SX23 5 SX23 SAMPLE SX24 5 SX24 SAMPLE
|
|
- Nora McCormick
- 5 years ago
- Views:
Transcription
1 MANUFACTURER PRODUCT NAME CATALOG OR PART NUMBER Amersham BCS NBCS104 Amersham BCS NA NBCS204 Beckman Ready Safe Scintiverse BD Cocktail ScintiSafe Econo ScintiSafe Econo ScintiSafe Econo R ScintiSafe 30% ScintiSafe Gel SX SX18 4 SX20 5 SX20 SAMPLE SX20-4 SX SX21 5 SX21 SAMPLE SX22 5 SX22 SAMPLE SX23 5 SX23 SAMPLE SX24 5 SX24 SAMPLE USES RECOMMENDED BY MANUFACTURER Designed for counting a wide variety of aqueous, inorganic, and organic samples at high capacities. Efficient counting of nonaqueous Multipurpose with high counting efficiency. Universal cocktail for aqueous, non-aqueous, and emulsion counting systems. Best at ambient temperatures for aqueous samples, dilute salt and buffer solutions, acids and bases, density gradients. As for ScintiSafe Econo 1, but performs well above and below ambient temperatures. 100% organic samples, dry filters, as an alternative to Toluene/PPO. High efficiency for swipe tests, dilute salt and buffer solutions, tritium counting. Suspension particle counting, TLC scrapings, soil samples, density gradients, biological
2 ScintiSafe Plus 50% SX25 5 SX25 SAMPLE Large volumes of aqueous sample, miniaturization, strong alkaline samples, wet filter counting for receptor binding assays. ICN EcoLume Aqueous and organic samples such as deionized water, phosphate buffered saline, PBS with gelatin or BSA, sucrose gradients, salt solution, 0.1N HCl, 0.1 N NaOH, etc. ICN EcoLite(+) Exceptional water and salt holding characteristics, and for difficult to count RIA samples, basic samples, phosphate buffers, and biological fluids. High H-3 and C-14 counting efficiencies. Gelling cocktail with ICN Universol ES physical characteristics of "triton and toluene" type cocktails. One-step counting of ICN CytoScint ES filters, TLC scrapings, and samples solublized in hyamine hydroxide. ICN BetaMax ES Beta particle counting in non-aqueous samples, samples dried on solid supports, and organic samples extracted from aqueous mixtures. National Diagnostics Ecoscint LS-271 Aqueous and nonaqueous
3 National Diagnostics Ecoscint A National Diagnostics Ecoscint O National Diagnostics Ecoscint H National Diagnostics Uniscint BD National Diagnostics Monoflow 5 Ultima Gold LS-273 LS-274 LS-275 LS-276 LS High efficiency for aqueous samples, resistance to photo- and chemiluminescence, biological samples, acrylamide gel slices. Non-aqueous samples, lower background, improved quench resistance compared with non biodegradable solutions. High efficiency for aqueous sample volumes under 10% of total sample volume, resistance to photo- and chemiluminescence, biological samples, acrylamide gel slices. Accommodates high salt and buffer samples, nongelling, suitable for use in on-line HPLC flow detectors. Nontoxic, biodegradable scintillator for flow detectors (ratios of 3:1). Very high counting efficiency, high capacity, for aqueous or nonaqueous samples, high quench resistance. Ultima Gold XR Extended range of sample holding capacity, high quench resistance, high counting efficiency.
4 Ultima Gold LLT (4 x 2.5 liters) High water capacity, high counting efficiency, very low background levels, for bioassay of urine, high heavy metal sample capacity. Ultima Gold MV Fast and easy sample mixing, high counting efficiency, ideal for counting small volumes, vortexing and counting wet glass fiber filters. Ultima Gold F Ultima Gold AB High counting efficiencies for dried filters, filter mats and organic samples, alpha and beta LSC counting. Excellent alpha/beta discrimination, excellent for strong mineral acids, high quench resistance, high sample capacity. Opti-Fluor Multi-purpose cocktail, low photo and chemiluminescence. Opti-Fluor O Poly-Fluor Ultima-Flo M (20 liters) Non-aqueous organic Economical sample counting. Multi-Purpose flow cocktail, high counting efficiency, low viscosity, non-gelling. / Ultima-Flo AF Specifically formulated for ammonium formate, high counting efficiency, low viscosity, non-gelling.
5 Research Products Bio-Safe II Aqueous solutions, salt/buffer solutions, biological materials, organic solutions, wet filters. Research Products Bio-Safe NA Highest efficiency when counting organic miscible samples and dry filters. Research Products Econo-Safe Wallac OptiScint HiSafe II Wallac OptiPhase HiSafe Wallac OptiPhase HiSafe General purpose cocktail for aqueous and nonaqueous Suitable for all organic General purpose cocktail with a moderate to high sample holding capacity for a wide range of aqueous and nonaqueous solutes. Capable of handling a broad range of solutes, very high level of sample acceptance particularly for high ionic strength solutes. Wallac OptiPhase Hi-Load No description available Wallac OptiPhase SuperMix Wallac OptiPhase TriSafe Wallac Betaplate Scint For use with microtitration plates. High solute uptake and low background, ideal for extended counting times. For samples harvested or spotted onto filter membranes.
Radioactive Waste Requirements
Radioactive Waste Requirements October 2013 Office of Environment, Health & Safety TABLE OF CONTENTS UC Berkeley,... 2 1.0 General Information, Requirements and Precautions... 3 1.1 Radioactive Waste Records/Request
More informationProper Segregation and Disposal of Low-Level Radioactive Waste Procedures
Proper Segregation and Disposal of Low-Level Radioactive Waste Procedures Manual Applies To: University of Michigan personnel preparing low-level radioactive waste for collection. Table of Contents Table
More informationBasics of a/b Discrimination for Liquid Scintillation Counting
application Note Liquid Scintillation Basics of a/b Discrimination for Liquid Scintillation Counting Author Ronald Edler, PhD and Chuck Passo PerkinElmer, Inc. 940 Winter Street Waltham, MA USA Introduction
More informationRadio-HPLC Flow Cells
Radio-HPLC Flow Cells Innovative Technology Expands the Limits of Radio-HPLC Detection The Most Versatile Flow Cells Packard s Radiomatic TM flow scintillation analyzers and flow cells have been integrated
More informationTECHNETIUM-99 IN WATER
Analytical Procedure TECHNETIUM-99 IN WATER (TEVA DISC METHOD) 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in water. 1.2. This method does not address all aspects
More informationPhase stability and lithium loading capacity in a liquid scintillation cocktail
Phase stability and lithium loading capacity in a liquid scintillation cocktail Denis E. Bergeron, H. Pieter Mumm, Mark Tyra Physical Measurement Laboratory, National Institute of Standards and Technology,
More informationTECHNETIUM-99 IN SOIL
Analytical Procedure TECHNETIUM-99 IN SOIL 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in soil. 1.2. This method does not address all aspects of safety, quality
More informationCOMPARATIVE STUDY BETWEEN EXTERNAL STANDARD METHOD AND INTERNAL STANDARD METHOD FOR LOW-LEVEL TRITIUM MEASUREMENTS
International Conference Nuclear Energy in Central Europe 2001 Hoteli Bernardin, Portorož, Slovenia, September 10-13, 2001 www: http://www.drustvo-js.si/port2001/ e-mail: PORT2001@ijs.si tel.:+ 386 1 588
More informationA New Measurement Method For Tritium Rapid Detection by LSC. IM.CAEP Xu Qinghua
A New Measurement Method For Tritium Rapid Detection by LSC IM.CAEP Xu Qinghua xuqinghuawork@sina.com Outline Background Results and discussion Materials and methods Background FOM value for channel Sample
More informationTECHNETIUM-99 IN WATER
Analytical Procedure TECHNETIUM-99 IN WATER (WITH VACUUM BOX SYSTEM) 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in water. 1.2. This method does not address all
More informationAcronyms, Abbreviations, and Symbols Foreword to the First Edition Foreword to the Second Edition Preface to the First Edition Preface to the Second
Contributors p. xxix Acronyms, Abbreviations, and Symbols p. xxxi Foreword to the First Edition p. xliii Foreword to the Second Edition p. xlv Preface to the First Edition p. xlvii Preface to the Second
More informationLIQUID SCINTILLATION COUNTERS. {Beta Counters}
LIQUID SCINTILLATION COUNTERS {Beta Counters} We offer a range of Alpha, Beta & Gama counters, from Hidex Oy, Finland to meet your specific Liquid Scintillation counting requirements. Triathler LSC Sense
More informationEffect of liquid scintillating cocktail volume on 3 H and 14 C measurement parameters using a Quantulus spectrometer
NUKLEONIKA 2010;55(2):155 161 ORIGINAL PAPER Effect of liquid scintillating cocktail volume on 3 H and 14 C measurement parameters using a Quantulus spectrometer Andrzej Komosa, Katarzyna Ślepecka Abstract.
More informationValidation of detection efficiency of alpha particles in commercial liquid scintillation counters
Validation of detection efficiency of alpha particles in commercial liquid scintillation counters Liquid Scintillation Users' Forum 14th October 2008 Andy Pearce Radionuclide and Neutron Metrology Group
More informationPractical Approaches using TDCR Measurements and Alpha/Beta Separation
Practical Approaches using TDCR Measurements and Alpha/Beta Separation Jost Eikenberg, Maya Jäggi, Andreas Brand Division for Radiation Protection and Safety Paul Scherrer Institute, CH-5232 Villigen Overview
More informationMethod Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples
Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction
More informationPRACTICAL 3 ph AND BUFFERS
PRACTICAL 3 ph AND BUFFERS ph and Buffers Structure 3.1 Introduction 3.2 ph and Buffers: Basic Concept 3.2.1 ph 3.2.2 Buffers and Buffer Solutions 3.3 Methods for Determining ph Experiment 1: Measurement
More informationHigh Performance Liquid Scintillation Analyzers. For Any Research, Discovery or Environmental Application Challenging Your Lab
High Performance Liquid Scintillation Analyzers For Any Research, Discovery or Environmental Application Challenging Your Lab For over 50 years, PerkinElmer top LSA instruments Research and environmental
More informationDETERMINATION OF BETA EMITTERS IN MATERIALS FROM RESEARCH REACTOR DECOMISSIONING
DETERMINATION OF BETA EMITTERS IN MATERIALS FROM RESEARCH REACTOR DECOMISSIONING Andreas Vesely 1 Herbert Trombitas Helmut Lindauer Nuclear Engineering Seibersdorf, 2444 Seibersdorf, Austria. ABSTRACT.
More informationNICKEL-63/59 IN WATER
Analytical Procedure NICKEL-63/59 IN WATER 1. SCOPE 1.1. This is a method for the separation and measurement of nickel- 63/59 in water samples. 1.2. This method does not address all aspects of safety,
More informationIvanaJakonić 1, Nataša Todorović 2, JovanaNikolov 2, Ines KrajcarBronić 3, BranislavaTenjović 4, MiroslavVesković 2
Optimization of low-levellevel LS counter Quantulus 1220 for tritium determination in water samples IvanaJakonić 1, Nataša Todorović 2, JovanaNikolov 2, Ines KrajcarBronić 3, BranislavaTenjović 4, MiroslavVesković
More information10/16/17 ACIDS AND BASES, DEFINED WATER IS AMPHOTERIC OUTLINE. 9.1 Properties of Acids and Bases. 9.2 ph. 9.3 Buffers
ACIDS AND BASES, DEFINED A hydrogen atom contains a proton and an electron, thus a hydrogen ion (H + ) is a proton: Acids: Proton (H + ) transfer between molecules is the basis of acid/base chemistry Ø
More informationHidex 300 SL Automatic TDCR Liquid Scintillation Counter
Hidex 300 SL Automatic TDCR Liquid Scintillation Counter The new dimension of versatility Our mission is to help your lab become more effective and make your work a pleasure by providing user-friendly
More informationPreparation of Tritium Labeled Compounds and Their Scintillation Proximity Assays
Preparation of Tritium Labeled Compounds and Their Scintillation Proximity Assays Michael P. O'Malley*, Yui S. Tang, and Nadine M. Gan PerkinElmer Health Sciences, Inc. * Main author: e-mail Mike.O Malley@Perkinelmer.com
More information1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer
1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer PerkinElmer LAS (UK) Ltd, Chalfont Rd, Seer Green, Beaconsfield, Bucks HP9 2FX tel: 0800 896046 www.perkinelmer.com John Davies January
More informationDetermination of 210 Pb and 210 Po in Water Samples
1 Determination of 210 Pb and 210 Po in Water Samples Marin Ayranov 1, Zornitza Tosheva 2, Antoine Kies 2 1 Institute for Nuclear Research and Nuclear Energy, 72 Tzarigradsko chaussee, BG-1784 Sofia, Bulgaria
More informationWater - HW. PSI Chemistry
Water - HW PSI Chemistry Name 1) In a single molecule of water, the two hydrogen atoms are bonded to a single oxygen atom by A) hydrogen bonds. B) nonpolar covalent bonds. C) polar covalent bonds. D) ionic
More informationRADIOLOGICAL CHARACTERIZATION Laboratory Procedures
RADIOLOGICAL CHARACTERIZATION Laboratory Procedures LORNA JEAN H. PALAD Health Physics Research Unit Philippine Nuclear Research Institute Commonwealth Avenue, Quezon city Philippines 3-7 December 2007
More informationParaquat ELISA Kit. Catalog Number KA assays Version: 17. Intended for research use only.
Paraquat ELISA Kit Catalog Number KA1424 96 assays Version: 17 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Background... 3 Principle of the Assay... 3 General Information...
More informationSCINTILLATION SYSTEMS CATALOG
BR-8127A SCINTILLATION SYSTEMS CATALOG LS 6000 Series Supplies and Accessories Ready Safe 1.4016.64InIglatmlocilmli.mos4etro BECKMAN REady Ca,SER PROCA 8 RE01E1 ID: RECEPTOR 4 Dt;. 07; tine: 15.8 " ates:
More informationTechnical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use
Technical data and operating instructions Vivaspin 4 Vivaspin 4 10K device for in vitro diagnostic use 85030-516-16 85030-516-16 Vivaspin 4 ml Introduction Storage conditions shelf life Vivaspin 4 ultrafiltration
More informationSolutions. Experiment 11. Various Types of Solutions. Solution: A homogenous mixture consisting of ions or molecules
Solutions Solution: A homogenous mixture consisting of ions or molecules -Assignment: Ch 15 Questions & Problems : 5, (15b,d), (17a, c), 19, 21, 23, 27, (33b,c), 39, (43c,d),45b, 47, (49b,d), (55a,b),
More informationProPac WCX-10 Columns
ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,
More informationMake a mixture of a weak acid and its conjugate base (as the SALT) Make a mixture of a weak base and its conjugate acid (as the SALT)
175 BUFFERS - resist ph change caused by either the addition of strong acid/base OR by dilution Made in one of two ways: Make a mixture of a weak acid and its conjugate base (as the SALT) Make a mixture
More information5. What is the name of the phase transition that occurs when a solid is converted directly into a gas (without going through the liquid phase)?
1. If the volume of a confined gas is doubled while the temperature remains constant, what change (if any) would be observed in the pressure? a. It would be half as large. b. It would double. c. It would
More informationParticle Characterization Laboratories, Inc.
Analytical services Particle size analysis Dynamic Light Scattering Static Light Scattering Sedimentation Diffraction Zeta Potential Analysis Single Point Titration Isoelectric point determination Aqueous
More informationProtease Inhibitor Cocktail A (1 tablet / 7 10 ml, Roche Cat# ) Protease inhibitor Cocktail B (0.5ml per 250ml, Calbiochem Cat# )
Protocol for Western Blotting Tissue/Cell Sample Preparation Lysis Buffer 1 (ph8.0) o 50mM Tris-Cl o 150mM NaCl o 1% v/v NP40 o protease inhibitor cocktail A/B Lysis Buffer 2 (RIPA) (ph 8.0) o 50mM Tris-Cl
More informationScintillation Proximity Assay on the TopCount Microplate Scintillation Counter
TCA-004 Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter Abstract Scintillation Proximity Assay (SPA) is a technique for performing binding assays without separation of bound
More informationIDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC
A. IDENTIFICATION BY TLC 1. SCOPE AND FIELD OF APPLICATION The method describes the identification of hydroquinone in cosmetic products. 2. PRINCIPLE Hydroquinone is identified by thin layer chromatography
More informationGeochemical dating of a Swiss freshwater limestone cave using 230 Th/ 234 U ingrow and 226 Ra-excess decay chronometry
Geochemical dating of a Swiss freshwater limestone cave using Th/ 234 U ingrow and Ra-excess decay chronometry Jost Eikenberg, Maya Jäggi Division for Radiation Protection and Safety Paul Scherrer Institute,
More informationMultiplexing immunoassay with SERS
Multiplexing immunoassay with SERS Neelam Kumarswami 24th Feb 29 5 4 3 42_421_44 42_421_47 42_421_47(2) 42_44_47 44_47_42(2) 421_44_47 421_44_47(2) Intensity 2 1 6 8 1 12 14 16 18 Aim of the project Robust,
More informationEnzymatic Assay of PROTEIN KINASE C
PRINCIPLE: Histone +? 32 P-ATP Protein Kinase > [ 32 P]-Phosphorylated Histone + ADP Abbreviations used:? 32 P-ATP = Adenosine 5'-Triphosphate? 32 P-labelled ADP = Adenosine 5'-Diphosphate CONDITIONS:
More informationSOLUTIONS CHAPTER 13
SOLUTIONS CHAPTER 13 SOLUTIONS Solutions, also known as homogeneous mixtures, are composed of two components: solute and solvent. In a sugar-water solution, water acts as a solvent (dissolving medium);
More informationCellufine Butyl Cellufine Phenyl
Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet Introduction For purification of proteins and macromolecules Hydrophobic Interaction Chromatography (HIC)
More informationQuickZyme Hydroxyproline Assay
QuickZyme Hydroxyproline Assay December 2015 This package insert must be read in its entirety before using this product. FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. Introduction Dysregulation
More informationHidex LSCs. LSC 2013 Barcelona
4.9.2013 1 4.9.2013 2 Hidex LSCs LSC 2013 Barcelona On Sunday March 24th Hidex is celebrating 20 years in the liquid scintillation counting community. Method to validate beef needed? Contents Hidex 300
More informationDiquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation
EPA Method 549.2 Revision 1.0 Determination of Diquat and Paraquat in Drinking Water by Liquid-Solid Extraction and High Performance Liquid Chromatography with Ultraviolet Detection* UCT Products: ENVIRO-CLEAN
More informationTRITIUM DETERMINATION IN WATER
TRITIUM DETERMINATION IN WATER Ricardo M. Gavini 1 Autoridad Regulatoria Nuclear, Av. del Libertador 8250, 1429, Buenos Aires, Argentina. Abstract. An analytical procedure for the determination of tritium
More informationNCERT. [H O] Since water is in large excess, its concentration can be assumed to be constant and combining it with K provides a new constant K w
UNIT-5 PH AND PH CHANGE IN AQUEOUS SOLUTIONS YOU have already performed experiments on dynamic equilibrium between unionised salt and the ions produced by it on dissolving in a solvent. In this unit we
More information11. Introduction to Acids, Bases, ph, and Buffers
11. Introduction to Acids, Bases, ph, and Buffers What you will accomplish in this experiment You ll use an acid-base indicating paper to: Determine the acidity or basicity of some common household substances
More informationLIQUID SCINTILLATION
LIQUID SCINTILLATION - MEASURING PROCEDURES, NEW DEVELOPMENTS - DGFS e.v. German Society for Liquid Scintillation Spectrometry Karlsruhe Institute of Technology, 2015 Karlsruhe MOEBIUS Siegurd ERAT Stephan
More informationProper&es of Water. Lesson Overview. Lesson Overview. 2.2 Properties of Water
Lesson Overview Proper&es of Water Lesson Overview 2.2 Properties of Water THINK ABOUT IT Looking back at Earth from space, an astronaut called it the blue planet, referring to the oceans of water that
More informationCounting Solutions LSC Technical Tips from PerkinElmer
Counting Solutions LSC Technical Tips from PerkinElmer Introduction The advance of the nuclear industry in all its forms coupled with growing concerns for possible environmental contamination has led to
More informationApplication Note. An Optimum Solution for the Automatic Control of Cutting Oils
An Optimum Solution for the Automatic Control of Cutting Oils Cutting oils are widely used in many mechanical machining processes such as cutting and grinding. The chemical and physical parameters of the
More informationSero: p30 Crossover Electrophoresis for Semen
Safety Principle Equipment and supplies SAFETY WARNING Electrophoretic procedures have electrical hazards associated with them. Therefore, at minimum, the presence of two analysts is required during these
More informationTaKaRa BCA Protein Assay Kit
Cat. # T9300A For Research Use TaKaRa BCA Protein Assay Kit Product Manual Table of Contents I. Description... 3 II. Components... 3 III. Storage... 3 IV. Materials Required by not Provided... 3 V. Precautions
More informationLiquid Scintillation at NPL: Practical Applications
2003 LS User s Forum Liquid Scintillation at NPL: Practical Applications Andy Pearce CAIR, NPL 2 nd April 2003 Introduction Overview of applications Current projects Neutron-activated thioacetamide discs
More informationGross Alpha-Gross Beta Analysis in Water by Liquid Scintillation Counting (LSC)
Gross Alpha-Gross Beta Analysis in Water by Liquid Scintillation Counting (LSC) Bob Read, Ph.D. Director, Environmental Chemistry Laboratory Tennessee Department of Health Division of Laboratory Services
More informationDetermination of H-3 and C-14 in the frame of decommissioning projects at the Paul Scherrer Institute
Determination of H-3 and C-14 in the frame of decommissioning projects at the Paul Scherrer Institute Jost Eikenberg, Maya Jäggi, Max Rüthi Paul Scherrer Institute, CH-5232 Villigen, Switzerland Content
More informationNuclear Engineering Seibersdorf GmbH
Nuclear Engineering Seibersdorf GmbH Use of Cerenkov Counting for the Determination of 90 Sr in a Radwaste Treatment Facility Andreas Vesely Herbert Trombitas Helmut Lindauer LSC 2010 1 NES as Part of
More informationMixtures. Chapters 12/13: Solutions and Colligative Properties. Types of Solutions. Suspensions. The Tyndall Effect: Colloid
Mixtures Chapters 12/13: Solutions and Colligative Properties Solution - a homogeneous mixture of two or more substances in a single phase Soluble - capable of being dissolved Solutions - 2 Parts Solvent
More information6. Extraction. A. Background. (a) (b) (c) Figure 1. Mixing of Solvents
6. Extraction A. Background Extraction is a frequently used technique to selectively transfer a compound of interested from one solvent to another. Extraction is based on solubility characteristics of
More informationMicrodetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats
Application Note 24 Microdetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats INTRODUCTION Most spectrophotometric
More informationLiquid Chromatography
Liquid Chromatography 1. Introduction and Column Packing Material 2. Retention Mechanisms in Liquid Chromatography 3. Method Development 4. Column Preparation 5. General Instrumental aspects 6. Detectors
More informationLS6500 Scintillation Counting Systems
LS6500 Scintillation Counting Systems Agenda LS6500 Concepts and Design H# Plus - The Basis of Advanced Technology Low Level Counting Alpha/Beta Discrimination LS6500 Concepts Give reproducible results
More informationApplication Note. Abstract. Introduction. Experimental
Application Note Alpha/Beta ABA-004 Quantitation of Transuranium Elements in High Activity Waste (HAW) Using Alpha/Beta Liquid Scintillation Counting and Extractive Scintillators by Jim Floeckher Abstract
More informationTime-Resolved Liquid Scintillation Counting
CHAPTER 44 Time-Resolved Liquid Scintillation Counting Norbert Roessler, Robert J. Valenta, and Stat van Cauter ABSTRACT A comparison is made between standard, two-tube coincidence liquid scintillation
More informationNitric Oxide Synthase Ultrasensitive Colorimetric Assay
Package Insert Nitric Oxide Synthase Ultrasensitive Colorimetric Assay 96 Wells For Research Use Only v. 2.0 09.20.17 Eagle Biosciences, Inc. 20A NW Blvd., Suite 112, Nashua, NH 03063 Phone: 866-419-2019
More informationShodex TM ODP2 HP series columns
HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series
More informationIntroduction to biochemical practicals. Vladimíra Kvasnicová
Introduction to biochemical practicals Vladimíra Kvasnicová arrangement of practicals laboratory safety regulations laboratory equipment dealing with automatic pipette instructions: http://vyuka.lf3.cuni.cz/
More informationNitric Oxide Synthase Colorimetric Non-enzymatic Assay
Package Insert Nitric Oxide Synthase Colorimetric Non-enzymatic Assay 96 Wells For Research Use Only v. 1.0 Eagle Biosciences, Inc. 20A NW Blvd., Suite 112, Nashua, NH 03063 Phone: 866-419-2019 Fax: 617-419-1110
More information1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter
1/5 Specification Hidex 300 SL-SLL 100-240V AC and 24 V DC. Features Model (425-020) Super Low Level (SLL) Automatic TDCR Liquid Scintillation Counter with Guard Detector and Low Level PMTs General Description
More informationCation Exchange HPLC Columns
Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb
More informationINDBOND 3000 Dry Strength Resin for Paper
INDBOND 3000 Dry Strength Resin for Paper INDBOND 3000 Dry Strength Resins are specially formulated polymers designed for better paper making and to improve strength characteristics like burst factor,
More informationRESULTS YOU CAN COUNT ON
RESULTS YOU CAN COUNT ON Liquid Scintillation Counting Principle and the Application in Biological Research 1 2009 PerkinElmer liquid scintillation counting β particle Tri-Carb family of liquid scintillation
More informationNECi Nitrate Kits FAQs
Why use enzymes? Enzymes are catalysts that drive complex biological reactions. They happen to be excellent reagents for analytical chemistry because they are reliable, accurate, sensitive, selective,
More informationGlossary of Common Laboratory Terms
Accuracy A measure of how close a measured value is to the true value. Assessed by means of percent recovery of spikes and standards. Aerobic Atmospheric or dissolved oxygen is available. Aliquot A measured
More informationThe Isosorbide Mononitrate Extended-Release Tablets Revision Bulletin supersedes the currently official monograph.
Isosorbide Mononitrate Extended-Release Tablets Type of Posting Revision Bulletin Posting Date 5 Oct 2018 Official Date 8 Oct 2018 Expert Committee Chemical Medicines Monographs 2 Reason for Revision Compliance
More informationMethod Development with ZirChrom's Ion Exchange Phases
For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than
More informationPHYSICAL CONSTANTS: MELTING POINTS, BOILING POINTS, DENSITY
CRYSTALLIZATION: PURIFICATION OF SOLIDS ANSWERS TO PROBLEMS: 1. (a) (b) (c) (d) A plot similar to line A in Figure 5.1 on page 559 will be obtained. The line will be slightly curved. All of the substance
More informationChapter 17: Additional Aspects of Aqueous equilibria. Common-ion effect
Chapter 17: Additional Aspects of Aqueous equilibria Learning goals and key skills: Describe the common ion effect. Explain how a buffer functions. Calculate the ph of a buffer solution. Calculate the
More information11,12-EET/DHET ELISA kit
11,12-EET/DHET ELISA kit Catalog Number: DH5/DH15/DH25 Store at -20 C. FOR RESEARCH USE ONLY V.0522010 Introduction It is well known that arachidonic acid (AA) will be converted to EET by P 450 arachidonic
More informationNANO 243/CENG 207 Course Use Only
L12: Drug Loading & Quantification May 15, 2018 1. Drug loading techniques 1.1 Physical approaches Nanprecipitation Single emulsion Double emulsion Encapsulation Remote loading 1.2 Chemical approaches
More informationWe need to find the new concentrations of the species in this buffer system. Remember that we also DILUTED the solution by adding 5.0 ml of the HCl.
164 Take 100. ml of the previous buffer (0.05 M tris / 0.075 M tris-hcl), and add 5.0 ml of.10 M HCl. What is the ph of the mixture? The HCl reacts with the tris base, converting it to tris-hcl We need
More informationFormation of a salt (ionic compound): Neutralization reaction. molecular. Full ionic. Eliminate spect ions to yield net ionic
Formation of a salt (ionic compound): Neutralization reaction molecular Full ionic Eliminate spect ions to yield net ionic Hydrolysis/ reaction with water Anions of Weak Acids Consider the weak acid HF
More informationNon-Interfering Protein Assay Kit Cat. No
Visit our interactive pathways at /pathways User Protocol 488250 Rev. 5 January 2006 RFH Page 1 of 1 Non-Interfering Protein Assay Kit Cat. No. 488250 Note that this user protocol is not lot-specific and
More informationSupporting Online Material. On-Chip Dielectrophoretic Co-Assembly of Live Cells and. Particles into Responsive Biomaterials
Supporting Online Material On-Chip Dielectrophoretic Co-Assembly of Live Cells and Particles into esponsive Biomaterials Shalini Gupta, ossitza G. Alargova, Peter K. Kilpatrick and Orlin D. Velev* Description
More informationExperiment 8 - Double Displacement Reactions
Experiment 8 - Double Displacement Reactions A double displacement reaction involves two ionic compounds that are dissolved in water. In a double displacement reaction, it appears as though the ions are
More informationA solution is a homogeneous mixture of two or more substances.
UNIT (5) SOLUTIONS A solution is a homogeneous mixture of two or more substances. 5.1 Terminology Solute and Solvent A simple solution has two components, a solute, and a solvent. The substance in smaller
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More information(A) Effect of I-EPI-002, EPI-002 or enzalutamide on dexamethasone (DEX, 10 nm)
Supplemental Figure Legends Supplemental Figure 1. (A) Effect of I-EPI-002, EPI-002 or enzalutamide on dexamethasone (DEX, 10 nm) induced GR transcriptional activity in LNCaP cells that were transiently
More information6. Extraction. A. Background. (a) (b) (c) Figure 1. Mixing of Solvents
6. Extraction A. Background Extraction is a frequently used technique to selectively transfer a compound of interested from one solvent to another. Extraction is based on solubility characteristics of
More informationHPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia
HPLC Columns MANUAL HILICpak VT-50 2D Shodex HPLC Columns Europe, Middle East, Africa, Russia For technical support please use contact details shown below: SHOWA DENKO EUROPE GmbH Shodex Business Konrad-Zuse-Platz
More informationTIME-RESOLVED LIQUID SCINTILLATION COUNTING
[RADOCARBON, VOL 32, No. 3, 1990, P 381-386] TME-RESOLVED LQUD SCNTLLATON COUNTNG MCHAEL KESSLER Packard nstrument Company, One State Street, Meriden, Connecticut 06450 ABSTRACT. Historically, scientists
More informationAgilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent
More information1. Which substance will conduct the current in the solid state? 1. Diamond 2.Graphite 3.Iodine 4.Sodium chloride.
CHAPTER :SOLIDS 1. Which substance will conduct the current in the solid state? 1. Diamond 2.Graphite 3.Iodine 4.Sodium chloride. 2. Molten sodium chloride conducts electricity due to the presence of ions:
More informationBuffers Keep the Balance
Buffers Keep the Balance Introduction A buffer protects against rapid changes in ph when acids or bases are added to something. Every living cell and your blood contains natural buffer systems to protect
More informationCounting Solutions LSC Technical Tips from Packard
Counting Solutions LSC Technical Tips from Packard CS-004 (07/04/96) Introduction Environmental Sample Preparation for LSC By: J. Thomson & D.A. Burns The advance of the nuclear industry in all its forms
More informationAnalysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography
Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens
More information