Radio-HPLC Flow Cells

Size: px
Start display at page:

Download "Radio-HPLC Flow Cells"

Transcription

1 Radio-HPLC Flow Cells

2 Innovative Technology Expands the Limits of Radio-HPLC Detection The Most Versatile Flow Cells Packard s Radiomatic TM flow scintillation analyzers and flow cells have been integrated into research laboratories worldwide for the analysis of biological samples separated by liquid chromatography. Whether used for the metabolic profiling in drug metabolism and toxicology studies or for radiochemical purity and environmental fate studies, Radiomatic detectors have proven their ability to quantitate low level radiolabeled metabolites. The technological advances such as multichannel full spectrum analysis (MCA), time-resolved liquid scintillation counting (TR-LSC) technology, and an innovative flow cell design provide up to a 300% increase in sensitivity. Packard s flow cells are an integral part of the flow scintillation analyzer. They provide exceptional system performance to meet your analytical requirements. A variety of flow cell sizes and cell types are available to fit your application: High sensitivity and high efficiency. Reduction of radioactive waste and recovery of a portion or all of your sample. Analysis of samples labeled with low and high energy gamma emitters. Micro-volume or in-line mass spectrometry analysis. Radiopharmaceutical purity validation. TR-LSC Flow Cell Special flow cell windows made of a scintillating material form the basis to distinguish beta from background events. All Packard Quick Change flow cells are interchangeable within the same instrument. Therefore, only one Radiomatic flow scintillation analyzer needs to be purchased. A Radiomatic will change the way you conduct your radio- HPLC studies. Now, you can quantitate samples directly and be confident with your DPM results because they correlate exactly with the results on your liquid scintillation counter.

3 Choose the Flow Cell that Meets Your Needs Homogeneous Heterogeneous High Performance Gamma PET Homogeneous flow cells with volumes from 100 µl to 5000 µl provide the lowest backgrounds, highest signalto-noise ratio, and highest sensitivity of all flow detection schemes. The liquid scintillation cocktail such as Packard s Ultima-Flo TM environmentally safe cocktail is mixed with the column eluate in ratios as low as 1:1 without compromising performance. Exclusive Packard MCA technology eliminates interference due to background, chemiluminescence, and the effects of chemical quenching by spectral stripping. Micro-volume flow cells with volumes from 3 µl to 99 µl for homogeneous detection applications can be used for super fluid critical chromatography (SFC) and mass spectrometry. Heterogeneous flow cells with volumes from 50 µl to 300 µl are packed with fine grains of solid scintillating material within the coiled Teflon tubing of the flow cell. Heterogeneous detection eliminates consumable costs, reduces waste, and, because the sample is not mixed with liquid cocktails, allows total sample recovery. High performance flow cells with volumes of approximately 35 µl, 100 µl, 200 µl and 400 µl offer heterogeneous detection for applications that require high back pressure and high flow rates. These flow cells withstand pressures of up to 2000 psi. The unique packed cartridge design makes cartridge replacement easy. This may be necessary if the scintillating material becomes contaminated. Gamma flow cells for low and high energy gamma emitters are ideally suited for the high performance flow scintillation analysis of samples labeled with low and high energy gamma emitting nuclides. The Gamma-C flow cell is ideal for low energies below 70 kev such as 125 I and 109 Cd with counting efficiency better than 85% for 125 I. The Gamma-B flow cell is suited for mid to high energy nuclides above 70 kev such as 99m Tc, 131 I, and 201 Tl. Since the scintillator is in the window, there is no need for liquid cocktail, thus eliminating cocktail consumption and reducing waste generation. The PET flow cell is especially suited for the analysis of radiolabeled pharmaceuticals and their metabolites in Positron Emission Tomography (PET) applications. This flow cell provides PET centers with selective, highly sensitive detection of positron emitters such as 11 C, 13 N, 15 O, and 18 F. A unique flow cell design incorporates optically isolated bismuth germanate (BGO) scintillating windows resulting in signal-to-noise ratios unmatched by any other PET flow cell. Teflon is a registered trademark of E.I. Dupont Company.

4 Homogeneous Counting For High Sensitivity and High Efficiency Homogeneous methods provide the lowest backgrounds, highest sensitivity, highest efficiency and the best MDA for all isotopes. The homogeneous flow cell consists of Teflon tubing which is coiled between two scintillating windows. Teflon tubing is chosen because of its inertness and transparency characteristics to maximize light output yielding the highest counting efficiency. The scintillating windows form the basis of TR-LSC to achieve unprecedented low backgrounds and the highest signal-to-noise ratio. With homogeneous techniques, the column eluate is mixed with the liquid scintillation cocktail and passed through the flow cell. Homogeneous techniques are preferred to heterogeneous techniques for low energy isotopes such as 3 H and molecules with high molecular weight. Chemical quenching that may be introduced by homogeneous counting of eluates, such as solvent gradients, peptides, proteins, lipids, saccharides, and phenolic compounds, can be minimized by characterizing the sample. Display and analyze radiolabeled samples using Spectrum Analysis to accurately set energy windows and optimize counting conditions. Quench correction curves are automatically generated to obtain the most accurate DPM results. A 1024 channel MCA allows characterization of the sample to eliminate contributions including background and luminescence and to minimize effects of chemical quenching. Integrated Flow Path Reduces Cocktail Consumption and Minimizes Waste Generation Unlike other radio-hplc detectors, Radiomatic flow scintillation analyzers feature a built-in flow control system. An integrated cocktail pump delivers precise and accurate flow rates from 0.4 ml per minute to 20 ml per minute. The cocktail pump can be programmed to be activated only on demand. When you require sample recovery, simply program the electronic stream splitter to send any portion from 0%, 2% to 98%, and 100% to a fraction collector while the remainder is directed to the flow cell for counting. There is more. A waste management system separates cold waste from hot waste, dramatically reducing the volume of radioactive waste. The integrated flow control system also features a pressure sensor and flow diverter to monitor overpressure conditions. Flow is diverted away from the flow cell into the waste container.

5 Heterogeneous Detection Reduces Waste and Recovers Sample Packard s proprietary SolarScint TM cocktail provides superb resolution without the memory effects of many other packed scintillators. For applications that require total sample recovery, Packard offers a wide range of heterogeneous flow cells. Now, you can reduce radioactive waste with cocktail free counting for a wide range of applications. Your Choice of Solid Scintillators Choose from a variety of solid scintillators compatible with many applications. Particle sizes vary from 35 µm to 250 µm. Small particle sizes mean maximum light output and high counting efficiency. Choose from cerium activated lithium glass, cerium doped yttrium silicate, and a new advanced proprietary scintillator, SolarScint. SolarScint: A New Advanced Scintillator The inertness of SolarScint means compounds with complex matrices will not adsorb to the scintillating particles. No peak broadening, no contamination, and no memory effects. SolarScint is TR-LSC compatible resulting in low backgrounds and high signal-to-noise ratio. With small particle sizes of 35 µm to 60 µm, efficiency is better than 65% for 14 C. High Performance Flow Cells for Normal and Micro-Volume Applications Packard s high performance flow cells are packed with scintillating particles for normal HPLC and micro-volume HPLC. For mass spectrometry applications where peak resolution and minimizing dead volume are important, this specially constructed flow cell provides less than 1 µl dead volume. In addition, the glass cartridges are replaceable. All packed scintillator flow cells, whether in Teflon tubing or glass cartridges, will eventually become contaminated. Replacing cartridges is more cost effective than replacing the entire flow cell. Packard also offers Calcium Fluoride solid scintillator cells through special order.

6 Gamma Flow Cells with the Performance of a Discrete Gamma Counter Packard s Gamma-C and Gamma-B flow cells are ideally suited for high performance flow scintillation analysis of samples labeled with low and high energy gamma emitters. The exclusive design of the gamma flow cells with special scintillating windows Gamma-C, Gamma-B, and provides high PET flow cells counting efficiency, without the expenditure of cocktail. The Gamma-B flow cell for mid to high energy gamma emitters such as 111 In, 22 Na, and 99m Tc use special BGO scintillating windows. The high specific gravity of the Gamma-B flow cell nears and sometimes exceeds the performance of a discrete gamma counter using a 3 inch NaI detector. The Gamma-C flow cell incorporates europium doped calcium fluoride scintillating windows to yield better than 85% efficiency for 125 I and other soft gamma emitters. Packard s unique use of the multichannel analyzer allows an accurate spectra of the sample to be displayed and analyzed. Background and other interferences are eliminated. Use Spectrum Analysis to characterize the 99m Tc labeled sample. Accurately set a counting window from 10 to 85 kev to surround the photo peak and double-photon artifact.

7 PET and Specialty Flow Cells Expand Radio-HPLC Applications Packard s unique PET flow cell design optically isolates the BGO windows to increase the signal-to-noise ratio. PET Flow Cell The exclusive design of the PET flow cell is especially suited for the analysis of radiolabeled pharmaceuticals and their metabolites in PET applications. The PET flow cell incorporates optically isolated BGO windows resulting in superior signal-to-noise ratios. The high density and thickness of the BGO windows allow the 511 kev gamma rays to be more efficiently converted to photons. Packard s exclusive multichannel analyzer allows you to accurately set energy windows around the photo peak. The combination of MCA and the PET flow cell: 32 P Flow Cell For applications with high energy beta emitters such as 32 P, a Cerenkov flow cell provides high performance counting. For Cerenkov counting, efficiencies greater than 35% and backgrounds of only 1 to 2 CPM can be achieved. This flow cell utilizes cocktail free counting and requires high specific activity. This flow cell is ideal for preparative HPLC. Eliminates all crosstalk. Reduces background to CPM. Delivers superior signal-to-noise ratio. Rejects external radiation.

8 Worldwide Chemical and Technical Support for Any Application The Ultima-Flo family of environmentally safer cocktails. Packard s Flow Scintillation Analyzer Application Bibliography Recognizes Researchers Worldwide Packard s Radiomatic systems are the most cited radio- HPLC systems worldwide. Our current bibliography, available on request, cites over 1400 articles in open scientific literature describing results of research conducted using Radiomatic flow scintillation analyzers. Topics include chemical synthesis, drug metabolism, toxicology, other pharmaceutical studies, and agricultural/ industrial quality control. Packard Instrument Company 800 Research Parkway Meriden, CT U.S.A. Tel: Toll Free: Customer Support: Fax: Web site: webmaster@packardinstrument.com Packard International Offices: Australia +(61) ; Austria +(43) ; Belgium +(32) ; Canada (Main Office) +(1) ; Central Europe +(43) ; Denmark +(45) ; France +(33) ; Germany +(49) ; Italy +(39) ; Japan +(81) ; Netherlands +(31) ; Russia +(7095) ; Switzerland +(41) ; United Kingdom +(44) M3671 8/00 Printed in U.S.A. Safer Flow Detection Cocktails Packard's biodegradable cocktails for use in flow scintillation analyzers, the Ultima-Flo TM family, were developed to address the concerns of environmental safety. These environmentally safer cocktails satisfy all of the applications covered by the original, classical solvent based Flo-Scint cocktails. The high loading capacity of the Ultima-Flo cocktails means less cocktail required, longer residence times and higher sensitivity. Each cocktail has low viscosity and nongelling properties even at high sample loads ensuring trouble free counting and lower back pressures. Ultima-Flo cocktails resist quench, providing higher counting efficiencies and more counts per peak. Features High sample load capacity High counting efficiency and quench resistance Low viscosity Nongelling Compatible with TR-LSC technology Biodegradable High flash-point of approximately 140 C The Ultima-Flo Family Ultima-Flo M For multipurpose applications Ultima-Flo AF For Ammonium Formate gradients Ultima-Flo AP For Ammonium Phosphate gradients and multipurpose applications Finding New Ways to Provide a Quality Solution Packard s team of sales, service, and support personnel are ready to assist you. We strive for customer satisfaction by understanding applications and providing the best instrumentation and technologies to help our customers achieve their goals. Packard s products are designed and manufactured under an ISO 9001 certified system. They are designed, built, and tested in conformance with appropriate CSA, FCC, and IEC standards. Radiomatic, SolarScint, Ultima-Flo are trademarks or registered trademarks of Packard BioScience or its subsidiaries in the United States and/or other countries. 2000, Packard BioScience Company. All rights reserved.

Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter

Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter TCA-004 Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter Abstract Scintillation Proximity Assay (SPA) is a technique for performing binding assays without separation of bound

More information

Gamma Analyst Performance Characteristics (MDAs)

Gamma Analyst Performance Characteristics (MDAs) Application Note Gamma Analyst Performance Characteristics (MDAs) Introduction With so much attention being given to environmental issues, the process of sample characterization is challenging today s

More information

The detection of low energy, beta-emitting radionuclides can be

The detection of low energy, beta-emitting radionuclides can be RADIOACTIVE FLOW DETECTORS LIQUID OR SOLID SCINTILLATORS? Andrew R. Reich, Radiornatic Instruments & Chemical Co., Inc., Tampa, Florida 33611, U.S.A. The detection of low energy, beta-emitting radionuclides

More information

Application Note. Abstract. Introduction. Experimental

Application Note. Abstract. Introduction. Experimental Application Note Alpha/Beta ABA-004 Quantitation of Transuranium Elements in High Activity Waste (HAW) Using Alpha/Beta Liquid Scintillation Counting and Extractive Scintillators by Jim Floeckher Abstract

More information

FlowStar LB 513 HERM LB 500

FlowStar LB 513 HERM LB 500 detect and identify FlowStar LB 513 HERM LB 500 Radioactivity flow detectors for HPLC 2-Year Factory Warranty on all Berthold Instruments. FlowStar LB 513 Radioactivity flow detector for HPLC Flow monitoring

More information

LIQUID SCINTILLATION COUNTERS. {Beta Counters}

LIQUID SCINTILLATION COUNTERS. {Beta Counters} LIQUID SCINTILLATION COUNTERS {Beta Counters} We offer a range of Alpha, Beta & Gama counters, from Hidex Oy, Finland to meet your specific Liquid Scintillation counting requirements. Triathler LSC Sense

More information

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter 1/5 Specification Hidex 300 SL-SLL 100-240V AC and 24 V DC. Features Model (425-020) Super Low Level (SLL) Automatic TDCR Liquid Scintillation Counter with Guard Detector and Low Level PMTs General Description

More information

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer 1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer PerkinElmer LAS (UK) Ltd, Chalfont Rd, Seer Green, Beaconsfield, Bucks HP9 2FX tel: 0800 896046 www.perkinelmer.com John Davies January

More information

TECHNETIUM-99 IN WATER

TECHNETIUM-99 IN WATER Analytical Procedure TECHNETIUM-99 IN WATER (WITH VACUUM BOX SYSTEM) 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in water. 1.2. This method does not address all

More information

2100TR Liquid Scintillation Counter

2100TR Liquid Scintillation Counter 2100TR Liquid Scintillation Counter Description The Tri-Carb 2100TR liquid scintillation counter is computer-controlled, bench top liquid scintillation analyzer for detecting small amounts of alpha, beta

More information

TECHNETIUM-99 IN SOIL

TECHNETIUM-99 IN SOIL Analytical Procedure TECHNETIUM-99 IN SOIL 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in soil. 1.2. This method does not address all aspects of safety, quality

More information

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance

More information

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS Daniel Kutscher, 1 Jörg Bettmer, 2 Torsten Lindemann, 1 Shona McSheehy-Ducos, 1 Lothar Rottmann 1 1 Thermo Fisher Scientific, Germany 2

More information

TECHNETIUM-99 IN WATER

TECHNETIUM-99 IN WATER Analytical Procedure TECHNETIUM-99 IN WATER (TEVA DISC METHOD) 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in water. 1.2. This method does not address all aspects

More information

Hidex 300 SL Automatic TDCR Liquid Scintillation Counter

Hidex 300 SL Automatic TDCR Liquid Scintillation Counter Hidex 300 SL Automatic TDCR Liquid Scintillation Counter The new dimension of versatility Our mission is to help your lab become more effective and make your work a pleasure by providing user-friendly

More information

ISO INTERNATIONAL STANDARD. Measurement of radioactivity in the environment Soil Part 5: Measurement of strontium 90

ISO INTERNATIONAL STANDARD. Measurement of radioactivity in the environment Soil Part 5: Measurement of strontium 90 INTERNATIONAL STANDARD ISO 18589-5 First edition 2009-03-01 Measurement of radioactivity in the environment Soil Part 5: Measurement of strontium 90 Mesurage de la radioactivité dans l'environnement Sol

More information

FLASH CHROMATOGRAPHY

FLASH CHROMATOGRAPHY Turnkey Laboratories Solutions FLASH CHROMATOGRAPHY FC 3065 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES Analytical Technologies Limited An ISO 9001 Certified Company

More information

RESULTS YOU CAN COUNT ON

RESULTS YOU CAN COUNT ON RESULTS YOU CAN COUNT ON Liquid Scintillation Counting Principle and the Application in Biological Research 1 2009 PerkinElmer liquid scintillation counting β particle Tri-Carb family of liquid scintillation

More information

DETERMINING FUNDAMENTAL PARAMETERS OF A SINGLE-PHOTOTUBE LIQUID SCINTILLATION COUNTER

DETERMINING FUNDAMENTAL PARAMETERS OF A SINGLE-PHOTOTUBE LIQUID SCINTILLATION COUNTER DETERMINING FUNDAMENTAL PARAMETERS OF A SINGLE-PHOTOTUBE LIQUID SCINTILLATION COUNTER Pall Theodórsson Science Institute, University of Iceland, Dunhaga 3, IS-107 Reykjavík, Iceland. Email: pth@raunvis.hi.is.

More information

MetWorks Metabolite Identification Software

MetWorks Metabolite Identification Software m a s s s p e c t r o m e t r y MetWorks Metabolite Identification Software Enabling Confident Analysis of Metabolism Data Part of Thermo Fisher Scientific MetWorks Software for the Confident Analysis

More information

Time-Resolved Liquid Scintillation Counting

Time-Resolved Liquid Scintillation Counting CHAPTER 44 Time-Resolved Liquid Scintillation Counting Norbert Roessler, Robert J. Valenta, and Stat van Cauter ABSTRACT A comparison is made between standard, two-tube coincidence liquid scintillation

More information

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery Metabolite Stability Screening and Hotspot Metabolite Identification by Combining High-Resolution, Accurate-Mass Nonselective and Selective Fragmentation Tim Stratton, Caroline Ding, Yingying Huang, Dan

More information

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems Yan Liu, Zhongqing Lu, and Chris Pohl; Thermo Fisher Scientific, Sunnyvale, CA USA Overview

More information

Working Copy. P /ru /,6. 8-tt tt. EffectiveDate: I ^, Operation and Calibration of the Tri-Carb Liquid Sclntillation Counter QAM-RI.106.

Working Copy. P /ru /,6. 8-tt tt. EffectiveDate: I ^, Operation and Calibration of the Tri-Carb Liquid Sclntillation Counter QAM-RI.106. QAM-RI.106 Operation and Calibration of the Tri-Carb Liquid Sclntillation Counter Revision: 0 Laboratory Man ager/lqao/rso Date Date EffectiveDate: I ^, P /ru /,6 8-tt tt Renewal Date: lnitials: Texas

More information

Basics of a/b Discrimination for Liquid Scintillation Counting

Basics of a/b Discrimination for Liquid Scintillation Counting application Note Liquid Scintillation Basics of a/b Discrimination for Liquid Scintillation Counting Author Ronald Edler, PhD and Chuck Passo PerkinElmer, Inc. 940 Winter Street Waltham, MA USA Introduction

More information

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic

More information

FLOWSTAR² LB 514. Radio detector for HPLC. 2-Year Factory Warranty on all Berthold Instruments. detect and identify

FLOWSTAR² LB 514. Radio detector for HPLC. 2-Year Factory Warranty on all Berthold Instruments. detect and identify FLOWSTAR² LB 514 Radio detector for HPLC 2-Year Factory Warranty on all Berthold Instruments. FLOWSTAR² Maximum flexibility, outstanding sensitivity With over 50 years of experience Berthold Technologies

More information

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use Shih-Tse Jason Lai, Jia Wang, Brad Hart, Kristine Van Natta, Marta Kozak, Jorge Valdivia, Haibo Wang,

More information

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,

More information

COMPARATIVE STUDY BETWEEN EXTERNAL STANDARD METHOD AND INTERNAL STANDARD METHOD FOR LOW-LEVEL TRITIUM MEASUREMENTS

COMPARATIVE STUDY BETWEEN EXTERNAL STANDARD METHOD AND INTERNAL STANDARD METHOD FOR LOW-LEVEL TRITIUM MEASUREMENTS International Conference Nuclear Energy in Central Europe 2001 Hoteli Bernardin, Portorož, Slovenia, September 10-13, 2001 www: http://www.drustvo-js.si/port2001/ e-mail: PORT2001@ijs.si tel.:+ 386 1 588

More information

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography Yan Liu, Zhongqing Lu, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA USA Overview Purpose: In this work, new high-pressure

More information

of mass spectrometry

of mass spectrometry Thermo Scientific 253 Ultra High resolution isotope ratio MS Discover a new world of mass spectrometry Paleoclimatology Atmospheric science Biogeochemistry Petrology Discover the isotopic anatomy of molecules

More information

TIME-RESOLVED LIQUID SCINTILLATION COUNTING

TIME-RESOLVED LIQUID SCINTILLATION COUNTING [RADOCARBON, VOL 32, No. 3, 1990, P 381-386] TME-RESOLVED LQUD SCNTLLATON COUNTNG MCHAEL KESSLER Packard nstrument Company, One State Street, Meriden, Connecticut 06450 ABSTRACT. Historically, scientists

More information

High Performance Liquid Scintillation Analyzers. For Any Research, Discovery or Environmental Application Challenging Your Lab

High Performance Liquid Scintillation Analyzers. For Any Research, Discovery or Environmental Application Challenging Your Lab High Performance Liquid Scintillation Analyzers For Any Research, Discovery or Environmental Application Challenging Your Lab For over 50 years, PerkinElmer top LSA instruments Research and environmental

More information

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution

More information

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher Wiper Gold Edition Premium Wipe Test Counter Setting the bar higher Software - Simplicity, Re-defined Load your wipe into the well and press the button. Your wipe is counted and automatically converted

More information

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer m a s s s p e c t r o m e t r y Finnigan TC/EA High Temperature Conversion Elemental Analyzer Analyze Detect Measure Control Finnigan TC/EA High Temperature Conversion Elemental Analyzer Finnigan TC/EA

More information

CATALOG OR PART NUMBER SX SX18 4 SX20 5 SX20 SAMPLE SX20-4 SX SX21 5 SX21 SAMPLE SX22 5 SX22 SAMPLE SX23 5 SX23 SAMPLE SX24 5 SX24 SAMPLE

CATALOG OR PART NUMBER SX SX18 4 SX20 5 SX20 SAMPLE SX20-4 SX SX21 5 SX21 SAMPLE SX22 5 SX22 SAMPLE SX23 5 SX23 SAMPLE SX24 5 SX24 SAMPLE MANUFACTURER PRODUCT NAME CATALOG OR PART NUMBER Amersham BCS NBCS104 Amersham BCS NA NBCS204 Beckman Ready Safe Scintiverse BD Cocktail 60803 ScintiSafe Econo 1 45345 ScintiSafe Econo 2 45346 ScintiSafe

More information

The Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine!

The Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine! The Multi-Wiper HE High Energy Nuclear Medicine Well Counter The first multi-well counters designed specifically for Nuclear Medicine! * Comprehensive wipe testing with concise report in DPM * Available

More information

ISO Water quality Strontium 90 and strontium 89 Test methods using liquid scintillation counting or proportional counting

ISO Water quality Strontium 90 and strontium 89 Test methods using liquid scintillation counting or proportional counting INTERNATIONAL STANDARD ISO 13160 First edition 2012-07-15 Water quality Strontium 90 and strontium 89 Test methods using liquid scintillation counting or proportional counting Qualité de l eau Strontium

More information

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Trace Cations in Power Plant Waters Containing Morpholine Application Note 8 Determination of Trace Cations in Power Plant Waters Containing Morpholine INTRODUCTION Morpholine and ammonium are used as additives in power plant waters. Morpholine acts as a corrosion

More information

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry O. Scheibner, 1 P. van Baar, 2 F. Wode, 2 U. Dünnbier, 2 K. Akervik, 3 J. Humphries, 3 M. Bromirski 1

More information

Applied Nuclear Science Educational, Training & Simulation Systems

Applied Nuclear Science Educational, Training & Simulation Systems WWW.NATS-USA.COM Applied Nuclear Science Educational, Training & Simulation Systems North American Technical Services Bridging Technology with the Latest in Radiation Detection Systems The Center For Innovative

More information

Acronyms, Abbreviations, and Symbols Foreword to the First Edition Foreword to the Second Edition Preface to the First Edition Preface to the Second

Acronyms, Abbreviations, and Symbols Foreword to the First Edition Foreword to the Second Edition Preface to the First Edition Preface to the Second Contributors p. xxix Acronyms, Abbreviations, and Symbols p. xxxi Foreword to the First Edition p. xliii Foreword to the Second Edition p. xlv Preface to the First Edition p. xlvii Preface to the Second

More information

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION A purpose-built collection of the best-inclass components for forensic toxicology Whether you re challenged to present reliable and secure forensic sample

More information

columns IonPac SCS 1 Silica Cation Separator

columns IonPac SCS 1 Silica Cation Separator columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly

More information

IN QUALITATIVE ANALYSIS,

IN QUALITATIVE ANALYSIS, IN QUALITATIVE ANALYSIS, YOU VE ALWAYS HAD TO CHOOSE BETWEEN ACCURACY AND THROUGHPUT. NOW THERE S NO REASON TO ever have to. WATERS QUALITATIVE ANALYSIS solutions Waters ACQUITY UPLC System with the Waters

More information

Quality Assurance. Purity control. Polycrystalline Ingots

Quality Assurance. Purity control. Polycrystalline Ingots Quality Assurance Purity control Polycrystalline Ingots 1 Gamma Spectrometry Nuclide Identification Detection of Impurity Traces 1.1 Nuclides Notation: Atomic Mass Atomic Number Element Neutron Atomic

More information

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher Wiper Gold Edition Premium Wipe Test Counter This product is available through: JRT Associates 5 Nepperhan Avenue, Suite 2B Elmsford, NY 10523 800-221-0111 Setting the bar higher Software - Simplicity,

More information

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput Yi Zhang 1, Zhiqi Hao 1, Markus Kellmann 2 and Andreas FR. Huhmer

More information

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis Thermo Scientific Pesticide Explorer Collection Start-to-finish workflows for pesticide analysis Comprehensive Pesticide Analysis Solutions Pesticide Explorer Collection Selection table Lab Profile Routine

More information

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS Thermo Scientific ConFlo IV Universal Interface Continuous Flow Interface Isotope Ratio MS 3 ConFlo IV Universal Interface for Continuous Flow Isotope Ratio MS The development of Continuous Flow carrier

More information

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)

More information

Contamination Monitoring Radiation Safety Orientation Open Source Booklet 4 (June 1, 2018)

Contamination Monitoring Radiation Safety Orientation Open Source Booklet 4 (June 1, 2018) Contamination Monitoring Radiation Safety Orientation Open Source Booklet 4 (June 1, 2018) For more information, refer to the Radiation Safety Manual, 2017, RSP-3, Section 10 and the Quick Step Guide for

More information

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output.

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output. www.raytest.com Choose your application of ß + RADIATION chromatography stand alone software controlled chemical purity HPLC PET GABI 2x2 Nal (Tl) 0 1V output PET GABI 2x2 Nal (Tl) Gina-PCcontrolled TLC

More information

NICKEL-63/59 IN WATER

NICKEL-63/59 IN WATER Analytical Procedure NICKEL-63/59 IN WATER 1. SCOPE 1.1. This is a method for the separation and measurement of nickel- 63/59 in water samples. 1.2. This method does not address all aspects of safety,

More information

GAMMA RAY SPECTROSCOPY

GAMMA RAY SPECTROSCOPY GAMMA RAY SPECTROSCOPY Gamma Ray Spectroscopy 1 In this experiment you will use a sodium iodide (NaI) detector along with a multichannel analyzer (MCA) to measure gamma ray energies from energy level transitions

More information

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM Application Note: 320 Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM Key Words Metabolism Study Structure Elucidation Metabolite ID Mass Frontier Chromatography

More information

Institute of Isotopes Co., Ltd.

Institute of Isotopes Co., Ltd. Carbon-14 Labelled PESTICIDES Institute of Isotopes Co., Ltd. Konkoly Thege M. u. 29-33., Budapest, 1121 HUNGARY Tel.: +36 1 392 2577, +36 1 395 9081 Fax: +36 1 395 9247, +36 1 392 2575 commerce@izotop.hu

More information

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience. Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience. Pure Consumables More focus on your application The Pure consumable portfolio offers an unrivaled range of products

More information

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS Jason Lai, Jia Wang, Brad Hart, Pavel Aronov, Kristine Van Natta, Marta Kozak, Jorge Valdivia, Andy Jacobs, Haibo

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

Depth Distribution of H-3, C-14 and Co-60 in Decommissioning of the Biological Shielding Concrete of KRR-2

Depth Distribution of H-3, C-14 and Co-60 in Decommissioning of the Biological Shielding Concrete of KRR-2 Depth Distribution of H-3, C-14 and Co-60 in Decommissioning of the Biological Shielding Concrete of KRR-2 S.B. Hong, H.R. Kim, K.H. Chung, K.H. Chung, J.H. Park Korea Atomic Energy Research Institute

More information

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide Supported Liquid Extraction (SLE) Guide and FAQ s User Guide What is SLE? Supported Liquid Extraction (SLE) is an extraction technique that separates out compounds based on their affinity for one solvent

More information

ɣ-radiochromatography

ɣ-radiochromatography nuclear instruments Kapitel_y_Graphy.indd 1 19.08.09 10:27 n u c l e a r i n s t r u m e n t s Index HPLC-detectors TLC-detectors GABI* analog output GABI* digital output to PC minigita*, 1 trace scanner

More information

DI 3500 Discrete Aoalvzer

DI 3500 Discrete Aoalvzer DI 3500 Discrete Aoalvzer Automated Chemistry and Ion Analysis ':t O+Analytical:!, A World ofsolutions. - Discrete Analysis Efficient Microscale Chemistry Increasingly laboratories are being challenged

More information

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization Thermo Scientific K-Alpha + XPS Spectrometer Fast, powerful and accessible chemical analysis for surface and thin film characterization X-ray Photoelectron Spectroscopy Quantitative, chemical identification

More information

1.1. This is a method for the separation and measurement of 228 Ra in water via its beta emitting 228 Ac daughter.

1.1. This is a method for the separation and measurement of 228 Ra in water via its beta emitting 228 Ac daughter. Analytical Procedure RADIUM-228 IN WATER (WITH VACUUM BOX SYSTEM) 1. SCOPE 1.1. This is a method for the separation and measurement of 228 Ra in water via its beta emitting 228 Ac daughter. 1.2. This method

More information

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer Reiko Kiyonami, Mary Blackburn, Andreas FR Hühme: Thermo Fisher

More information

Hidex LSCs. LSC 2013 Barcelona

Hidex LSCs. LSC 2013 Barcelona 4.9.2013 1 4.9.2013 2 Hidex LSCs LSC 2013 Barcelona On Sunday March 24th Hidex is celebrating 20 years in the liquid scintillation counting community. Method to validate beef needed? Contents Hidex 300

More information

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry Olaf Scheibner, 1 Patrizia van Baar, 2 Florian Wode, 2 Uwe Dünnbier, 2 Kristi Akervik, 3 Jamie Humphrie,

More information

Unit 2. Instrumentation. Experts Teaching from Practical Experience

Unit 2. Instrumentation. Experts Teaching from Practical Experience Unit 2 Instrumentation Experts Teaching from Practical Experience Gas-Filled Detectors Gas-filled detectors measure the charge released when radiation interacts with the gas Three types: Ion Chambers,

More information

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer Defining quality standards for the analysis of solid samples Redefine your quality standards for the elemental analysis of solid samples

More information

[ Care and Use Manual ]

[ Care and Use Manual ] Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Application Note EPA Method 535 EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS API 3200 LC/MS/MS System Overview Described here is the

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Introduction What is FTIR? FTIR stands for Fourier transform infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR

More information

Calibration & Use of a Capintec CAPTUS 3000 Portable Thyroid Uptake System for Iodine-125 Bioassay Measurements Todd W.

Calibration & Use of a Capintec CAPTUS 3000 Portable Thyroid Uptake System for Iodine-125 Bioassay Measurements Todd W. Calibration & Use of a Capintec CAPTUS 3000 Portable Thyroid Uptake System for Iodine-125 Bioassay Measurements Todd W. Baker, MSPH, CHP Photo image area measures 2 H x 6.93 W and can be masked by a collage

More information

1 of 16 1/28/2014 2:35 PM. Search

1 of 16 1/28/2014 2:35 PM. Search 1 of 16 1/28/2014 2:35 PM Home Product Menu Geiger Counters Motion Control Servo Motor Index Biofeedback Devices Speech Recognition Servobotics PIC Microcontroller Holography Nitinol Products Electronic

More information

Multi-element process analyzer

Multi-element process analyzer Multi-element process analyzer Elemental analysis by X-ray fluorescence Compact multi-element process analyzer for liquid streams or f ixed position web applications Featuring advanced third generation

More information

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System Application Update 55 Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free System Introduction Hydrogen peroxide is an essential chemical in the fabrication

More information

SLAC Radioanalysis Laboratory

SLAC Radioanalysis Laboratory SLAC Radioanalysis Laboratory Henry Brogonia Dosimetry and Radiological Protection Group (DREP) DOE Environmental Radiation Protection Program Review (July 23-24, 2007) Radioanalysis Laboratory Mission

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy molecular spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Part of Thermo Fisher Scientific Introduction What is FT-IR? FT-IR stands for Fourier Transform InfraRed, the preferred method

More information

Automation of the radiochemical procedures for the sequential separation of radionuclides

Automation of the radiochemical procedures for the sequential separation of radionuclides LSC2017 - An International Conference on Advances in Liquid Scintillation Spectrometry, Copenhagen Denmark, 1 5 May 2017 Automation of the radiochemical procedures for the sequential separation of radionuclides

More information

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9. HICHROM Chromatography Columns and Supplies SAMPLE PREPARATION Solid Extraction - SOLA & HyperSep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 930 3660

More information

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection Terri Christison, Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA Overview

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 11704 First edition 2010-07-01 Water quality Measurement of gross alpha and beta activity concentration in non-saline water Liquid scintillation counting method Qualité de l'eau

More information

Radiation Detection and Measurement

Radiation Detection and Measurement Radiation Detection and Measurement June 2008 Tom Lewellen Tkldog@u.washington.edu Types of radiation relevant to Nuclear Medicine Particle Symbol Mass (MeV/c 2 ) Charge Electron e-,! - 0.511-1 Positron

More information

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD) The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD) Basically all compounds which are less volatile than the mobile phase can be detected. Detection is based on a Universal property of

More information

(CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM)

(CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM) Analytical Procedure RADIUM IN WATER (CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM) 1. SCOPE 1.1. This is a method for separation and measurement of radium-226 and radium-228 in water. This method

More information

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis Tim Stratton 1, Yingying Huang 1, Katianna Pihakari 1, Ian Acworth 2, and Michael Weber 2 1 Thermo Fisher Scientific,

More information

Laird Thermal Systems Application Note. Precise Temperature Control for Medical Analytical, Diagnostic and Instrumentation Equipment

Laird Thermal Systems Application Note. Precise Temperature Control for Medical Analytical, Diagnostic and Instrumentation Equipment Laird Thermal Systems Application Note Precise Temperature Control for Medical Analytical, Diagnostic and Instrumentation Equipment Contents Overview...3 Thermal Management Techniques...3 Application Examples...3

More information

ENHANCING SOLID-PHASE DISK EXTRACTION PERFORMANCE WITH DESIGN OF EXPERIMENTS

ENHANCING SOLID-PHASE DISK EXTRACTION PERFORMANCE WITH DESIGN OF EXPERIMENTS ENHANCING SOLID-PHASE DISK EXTRACTION PERFORMANCE WITH DESIGN OF EXPERIMENTS BY CRAIG A. PERMAN Product Development Specialist 3M Company Filtration Products Laboratory Building 60-1W-17 St. Paul, MN 55144

More information

HPLC Column Material - Bulk Ware

HPLC Column Material - Bulk Ware HPLC Column Material - Bulk Ware Constantly growing demands on separation efficiency and availability of solid phase material for packing HPLC columns and column packing stations have motivated us to provide

More information

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany Generic Method Approach for Pharmaceutical Drug Discovery and Development using Reversed-Phase Hydrophilic Interaction Liquid Chromatography with Universal Charged Aerosol Detection Frank Steiner, Michael

More information

ISO Water quality Determination of carbon 14 activity Liquid scintillation counting method

ISO Water quality Determination of carbon 14 activity Liquid scintillation counting method INTERNATIONAL STANDARD ISO 13162 First edition 2011-11-01 Water quality Determination of carbon 14 activity Liquid scintillation counting method Qualité de l eau Détermination de l activité volumique du

More information

Hidex Liquid Scintillation Counters

Hidex Liquid Scintillation Counters Hidex Liquid Scintillation Counters The new dimension of versatility Our mission is to help your lab become more effective and make your work a pleasure by providing user-friendly instruments with ultimate

More information

Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples

Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples Mashaba, Machel. 1*, Kotze, Deon. 2, Tshivhase, Victor.M. 1, Faanhof, Arnaud. 1, 2 1

More information

columns IonPac AS18 Anion-Exchange Columns

columns IonPac AS18 Anion-Exchange Columns columns IonPac AS Anion-Exchange Columns The IonPac AS is a hydroxideselective anion-exchange column designed for the determination of inorganic anions and low-molecularweight organic acids including fluoride,

More information

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Mass Spectral Studies of Polypropylene Chromatographic Well Plates Mass Spectral Studies of Polypropylene Chromatographic Well Plates Brian King, Thermo Fisher Scientific, Runcorn, Cheshire, UK Detlev Lennartz, Thermo Fisher Scientific, Langerwehe, Germany White Paper

More information

Monitoring Protein PEGylation with Ion Exchange Chromatography

Monitoring Protein PEGylation with Ion Exchange Chromatography Monitoring Protein PEGylation with Ion Exchange Chromatography Peter Yu, Deanna Hurum, Jinyuan (Leo) Wang, 2 Terry Zhang, 2 and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA; 2 Thermo Fisher Scientific,

More information