1 Background studies for the EDELWEISS dark matter experiment arxiv: v1 [physics.ins-det] 15 May 2013 The EDELWEISS Collaboration, E. Armengaud a, C. Augier b, A. Benoît c, A. Benoît b, L. Bergé d, T. Bergmann e, J. Blümer f,g, A. Broniatowski d, V. Brudanin i, B. Censier b, M. Chapellier d, F. Charlieux b, F. Couedo d, P. Coulter k, G.A. Cox f, M. De Jesus b, J. Domange d,a, A.-A. Drilien d, L. Dumoulin d, K. Eitel g, D. Filosofov i, N. Fourches a, J. Gascon b, G. Gerbier a, M. Gros a, S. Henry k, S. Hervé a, G. Heuermann f, N. Holtzer d, A. Juillard b, M. Kleifges e, H. Kluck f, V. Kozlov g, H. Kraus k, V.A. Kudryavtsev l,, H. Le Sueur d, P. Loaiza j,, S. Marnieros d, A. Menshikov e, X-F. Navick a, C. Nones a, E. Olivieri d, P. Pari h, B. Paul a, O. Rigaut d, M. Robinson l, S. Rozov i, V. Sanglard b, B. Schmidt f, S. Scorza b,1, B. Siebenborn g, S. Semikh i, D. Tcherniakhovski e, A.S. Torrento-Coello a, L. Vagneron b, R.J. Walker a,f, M. Weber e, E. Yakushev i, X. Zhang k a CEA, Centre d Etudes Saclay, IRFU, Gif-Sur-Yvette Cedex, France b IPNL, Université de Lyon, Université Lyon 1, CNRS/IN2P3, 4 rue E. Fermi Villeurbanne cedex, France c CNRS-Néel, 25 Avenue des Martyrs, Grenoble cedex 9, France d CSNSM, Université Paris-Sud, IN2P3-CNRS, bat 108, Orsay, France e Karlsruhe Institute of Technology, Institut für Prozessdatenverarbeitung und Elektronik, Karlsruhe, Germany Abstract f Karlsruhe Institute of Technology, Institut für Experimentelle Kernphysik, Karlsruhe, Germany g Karlsruhe Institute of Technology, Institut für Kernphysik, Karlsruhe, Germany h CEA, Centre d Etudes Saclay, IRAMIS, Gif-Sur-Yvette Cedex, France i Laboratory of Nuclear Problems, JINR, Joliot-Curie 6, Dubna, Moscow region, Russia j Laboratoire Souterrain de Modane, CEA-CNRS, 1125 route de Bardonnèche, Modane, France k University of Oxford, Department of Physics, Keble Road, Oxford OX1 3RH, UK l Department of Physics and Astronomy, University of Sheffield, Hounsfield Road, Sheffield S3 7RH, UK The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg days of effective exposure. A cross-section of pb is excluded at 90% C. L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few 10 9 pb. We present here the study of gamma and neutron background coming from radioactive decays in the set-up and shielding materials. We have carried out Monte Carlo simulations for the completed EDELWEISS-II setup with GEANT4 and normalised the expected background rates to the measured radioactivity levels (or their upper limits) of all materials and components. The expected gamma-ray event rate in EDELWEISS- II at kev agrees with the observed rate of 82 events/kg/day within the uncertainties in the measured concentrations. The calculated neutron rate from radioactivity of events (90% C. L.) at kev in the EDELWEISS-II data together with the expected upper limit on the misidentified gamma-ray events ( 0.9), surface betas ( 0.3), and muon-induced neutrons ( 0.7), do not contradict 5 observed events in nuclear recoil band. We have then extended the simulation framework to the EDELWEISS-III configuration with 800 g crystals, better material purity and additional neutron shielding inside the cryostat. The gamma-ray and neutron backgrounds in 24 kg fiducial mass of EDELWEISS-III have been calculated as events/kg/day and events per year, respectively. The results of the background studies performed in the present work have helped to select better purity components and improve shielding in EDELWEISS-III to further reduce the expected Corresponding authors: v.kudryavtsev@sheffield.ac.uk, ploaiza@lsm.in2p3.fr 1 Present address: Department of Physics, Southern Methodist University, Dallas, TX 75275, USA Preprint submitted to Elsevier August 11, 2016
2 rate of background events in the next phase of the experiment. Keywords: Dark matter; WIMPs; Background radiation; Radioactivity; The EDELWEISS experiment PACS: d; Ly; s; e. 2
3 1. Introduction The reduction and discrimination of the background is one of the most important tasks in any dark matter experiment as the signal rate expected from WIMPs is extremely low. EDELWEISS-II is a direct dark matter search experiment based on Ge bolometers. The combined measurement of the ionisation and heat in a particle interaction allows the rejection of the gamma background at the level of (3±1) 10 5 [1]. Interleaved electrode design, recently developed by the collaboration [2], enables an efficient rejection ( [3]) of near-surface interactions. Using 10 detectors representing a total mass of 4 kg and with a total effective exposure of 384 kg days, EDELWEISS-II has recently published its final WIMP search result [1]. A cross-section of 4.4 x 10 8 pb has been excluded at 90% C. L. for a WIMP mass of 85 GeV/c 2. To reach the sensitivity to WIMP-nucleon cross-section significantly below 10 8 pb in the next phase of the experiment, the background has to be further reduced. The sources of background are neutrons, gamma-rays and surface beta contaminants. Neutrons may be induced by cosmic-ray muons or generated by the decay of the natural radioactive elements present in the cavern walls and in the set-up components. Details on the muon-induced neutron studies using the EDELWEISS-II setup are given in Ref. [4], an additional liquid scintillator detector dedicated to the measurement of muon-induced neutrons is described in Ref. [5]. Gamma-rays and beta contaminants are produced by the radioactivity in the construction materials. Surface events induced by surface contaminants are discriminated using the interleaved electrodes. Ref. [1] gives details on the surface event background. We present in this paper studies of the gamma-ray and neutron background coming from radioactive decays in the set-up and shielding of EDELWEISS-II and EDELWEISS-III. Extensive Monte Carlo simulations have been performed and combined with radiopurity measurements of all materials. These background studies have been used for optimisation of the configuration of the next stage WIMP search experiment at Modane EDELWEISS-III. 2. Experimental set-up and simulations EDELWEISS-II is located in the Laboratoire Souterrain de Modane (LSM) where the rock overburden of 4800 m w.e. reduces the cosmic muon flux down to about 5 muons/m 2 /day [4]. The environmental gamma-ray flux below 4 MeV is dominated by natural radioactivity in the rock and concrete. The uranium, thorium and potassium concentrations have been reported in [6]: 0.84± 0.2 ppm and 1.9 ± 0.2 ppm of 238 U, 2.45± 0.2 ppm and 1.4 ± 0.2 ppm of 232 Th, 230±30 Bq/kg and 77.3±13 Bq/kg of K in the rock and concrete, respectively. The neutron flux above 1 MeV is about 10 6 n/cm 2 /s [7]. The radon level in the laboratory is 20 Bq/m 3 thanks to a ventilation system renewing the entire laboratory volume 1.5 times per hour. Further reduction of the radon level (down to 20 mbq/m 3 ) inside the shielding is achieved by the radon trap facility. EDELWEISS-II uses cryogenic germanium detectors installed in the 10 mk chamber of a dilution refrigerator specially designed for the experiment. Each detector is enclosed in an individual casing made of electrolytic copper of type CuC2 as termed by the manufacturer and characterised by high purity(99.99% pure) and concentration of oxygen limited to 5 ppm. The radiopurity of this copper has been measured at LNGS (Italy) using gamma-spectrometry [8] and the results are shown in Table 1. Only teflon (PTFE) is used to hold the detectors inside the casings in a design specially developed to obtain the lowest possible radioactive background [9]. The detectors are arranged on disks supported by three vertical bars. The disks and the vertical bars are themselves supported by a thick plate at 10 mk and surrounded by a 10 mk thermal screen. The 10 mk plate also plays the role of shielding the Ge crystals from the radioactivity beneath the plate. The 10 mk plate and the 10 mk thermal screen will be referred to hereafter as the 10 mk chamber. The disks, the bars and the 10 mk chamber are made of electrolytic copper of type CuC1 (with oxygen concentration less than 1 ppm and purity of 99.95%). The radiopurity of CuC1 copper has been measured at LSM. The results of the measurements are shown in Table 1. To simulate the response of the detectors to various types of particles, the complete set-up has been implemented in the GEANT4 package [10] as shown in Figure 1. 3
4 Figure 1: (Color online) The GEANT4 geometry of the EDELWEISS-II set-up. Left : 1 germanium detectors with casings, 2 copper disks supporting Ge detectors (10 mk), 3 support bars for the copper disks (10 mk), 4 10 mk thermal screen, 5 10 mk thick plate supporting inner detector components, 6 internal roman lead shielding, 7 1K thermal screen, 8 4.2K thermal screen, 9 40K thermal screen, K thermal screen, K vacuum chamber, 12 stainless steel liquid He reservoir, 13 stainless steel can. The outer lead shielding including modern and roman lead, is shown in grey. The outer polyethylene shielding and the muon veto are not shown. Right: zoom of the central part showing the germanium detectors with casings (dark yellow and grey) stacked on the copper disks (blue), the vertical support bars (dark yellow), the 10 mk thick plate (dark yellow) and, at the bottom, part of the internal roman lead shielding (grey). Below the 10 mk plate, at 1K, 14 cm of roman lead shields the detectors from the gamma-rays induced by the radioactivity in the cold electronics, the dilution unit and other cryogenic parts. The dilution unit components are made of copper, stainless steel and silver. Four thermal screens at 1K, 4.2K, 40K, 100K and the vacuum chamber at 300K, all made of copper which has not been specially selected for its ultra-low radioactivity, complete the cryostat. Hereafter the thermal screens from 1K to 100K and the vacuum chamber at 300K will be referred to as screens 7 to 11 according to the numbering in Figure 1. EDELWEISS-II uses coaxial cables from the detectors to room temperature. Resistors together with electrical connectors are installed at the 1K stage below the lead shielding. Cold JFETs are positioned at the 100K stage. The electronics to bias the JFETs, the DACs to bias the detectors, the final amplification, the anti-aliasing filter and the digitisation are all integrated in a single room-temperature module, called bolometer box, which is attached to the stainless steel can (see Figure 1 for details of the set-up, bolometer boxes are not shown). An 18 cm thick outer layer of modern lead shields the cryostat against ambient gamma-ray background. A 2 cm thick inner roman lead layer has been cast directly on the modern lead. An outer 50 cm thick polyethylene shielding protects the detector against ambient neutrons. The lead and polyethylene shielding is mounted on a mild steel structure with rails allowing the opening of the two halves of the shielding structure. In addition an 100 m 2 plastic scintillator active muon veto surrounds the polyethylene [5]. All materials used in the construction have been measured to assess their radioactive contaminations. Table 1 shows a selection of the results. The CuC2 copper of the detector casings was purchased in 2006 and stored in LSM since then. A few samples of this copper have been exposed to cosmic rays for a few days during their transportation from LSM to LNGS for accurate measurements of radiopurity. Decay rates of cosmogenic isotopes (see Table 1) agree with the assumption of a few day activation. 4
5 Table 1: Radioactive contaminations in materials of the EDELWEISS-II set-up and shielding. All contaminations have been assessed by gamma-ray spectrometry, except for 238 U and 232 Th in lead and mild steel which have been measured by mass spectrometry, and 238 U and 232 Th in polyethylene measured by neutron activation. The radioactivity quoted for the dilution unit is based on measurement of individual components. Component/ Mass Radioactivity in materials (mbq/kg or mbq/unit ) Material (kg) 226 Ra 228 Th 60 Co 40 K Other radionuclides Detector holders/ptfe 0.02 <7 <5 <20 < Pb<80 Electrodes/Al < ± ± ± Al: 0.38± Detector casings/ < U< 1.4, 235 U< 0.9 CuC2 copper a ±0.015 ±0.016 ± Mn: 0.024±0.010 b Disks, bars, 10 mk chamber/ 90 <1 <0.7 <1 < Pb:180±140 CuC1 copper Screens 7 to 11/copper 320 <3 <2 <2 <25 Dilution unit 1 <20 <20 <20 < Ag:331 ±32 1K connectors ± ±138 < ± U:1994±204 Coaxial cables ±7 <6 <8 120 ± Pb<110 Bolometer boxes 50 units 331±17 235±13-340± U:134 ± (warm electronics) 210 Pb :1019±56 Roman lead shield 120 <0.3 <0.3 - < Pb<120 Modern lead shield <3 < Pb: (24±1) U< 0.01 ppb Polyethylene shield ±1 <2 <3 16±2 238 U:1 ppb, 232 Th:0.1 ppb Mild steel support U< 0.01 ppb 232 Th< 0.01 ppb a CuC2 copper has been measured at LNGS with the GeMPI detector [8]. b The activities of short-lived cosmogenic isotopes in CuC2 copper correspond to (10±2) days of exposure. 3. Gamma background The Monte Carlo simulation was based on the GEANT4 code with the Low Energy Electromagnetic Interactions physics list. Cross-sections are determined from evaluated data (EPDL97, EEDL and EADL, stopping power data, binding energy based on data of Scofield) [12]. The particle generator uses the GEANT Radioactivity Decay generator (GRDM), which was designed to handle all kinds of decays (α, β, β +, EC), the emission of the associated particles and energy distribution, the following de-excitation of the nucleus (γ, internal conversion) and the accompanying X-rays and Auger electrons [12]. The GRDM generator takes into account the total energy loss occurring due to the cascade gamma emission. All emitted particles were followed in GEANT4 and energy depositions in the crystals were stored. Energy depositions occurring in the same crystal within the time window of 50 ms were summed together giving a single event. In a subsequent analysis the fiducial events have been defined in the same way as in real data and the fiducial volume cut was applied to the simulated events. The decays of 226 Ra, 228 Ra, 60 Co, 40 K, 54 Mn and 210 Pb were simulated in the detector casings, the disks supporting the Ge detectors, the bars supporting the disks, the 10 mk chamber, the cryostat screens 7 to 11, the dilution unit (as a block for simplicity), 1K connectors, the coaxial cables and the lead shielding (see Figure 1). To simplify the simulation task 228 Ra was assumed to be in equilibrium 5
6 with 228 Th. In addition, the cosmogenically induced isotopes 68 Ge and 65 Zn in germanium crystals were considered and their activities were chosen to match the measured intensities of the lines at around 10 kev. PTFE crystal holders, aluminium electrodes and other small parts located close to the crystals have too small mass to give a measurable contribution to the gamma-ray background but their contribution to the neutron background may be enhanced due to high (α,n) cross-sections, in particular on aluminium and fluorine (see Section 4). The coaxial cables, the dilution unit and 1K connectors (Table 1) are located below the 14 cm thick lead plate and their contribution was found to be negligible compared to that of the cryostat screens 7 to 11 despite higher radioactivity levels. The gamma-ray background from bolometer boxes (warm electronics) was not simulated as they were located behind lead. The contribution from 210 Bi in the modern lead shielding is negligible but the energetic gammas of about 2.6 MeV from 228 Th decay chain may reach the detectors, as shown in Table 2. The background from rock and concrete was shown to be suppressed by several ordersof magnitude due to the lead shielding around the cryostat. As only upper limits were obtained in the radioactivity measurements for CuC1 copper and the copper of the screens 7 to 11, a χ 2 minimisation with 10 free parameters was used to determine those contaminations. The 10 free parameters were: 226 Ra and 228 Ra in CuC1 copper (disks, bars and 10 mk chamber), 226 Ra and 228 Ra in copper of the screens 7 to 11 and 226 Ra and 228 Ra contamination at 300K (not shown in Table 1) which could be due to unaccounted radioactivity in cryogenic pipes, electronics, radon or uncontrolled impurities on the 300K vacuum chamber (6 parameters in total); cosmogenic 60 Co and 54 Mn in CuC1 and copper of the screens 7 to 11 (assumed to be the same), 40 K in CuC1 and copper of the screens 7 to 11 (assumed to be the same) and 210 Pb on the surface of the detector casings. The radiopurity measurements reported in Table 1 for CuC2 copper were used to calculate the gamma contributions from CuC2 copper parts. The upper limits for other copper parts were taken as upper bounds for the fitting procedure. counts/3kev kev Th 352 kev 226 Ra 511 kev kev Th kev Ra 1173 kev kev Co kev K data Edelweiss-II MC (Fit 1) kev Th counts/1kev kev Pb data Edelweiss-II MC (Fit 1) Ionization energy [kev] Ionization energy [kev] Figure 2: The background ionisation energy spectrum in the fiducial volume of the EDELWEISS-II detectors from measured data (black line) and Monte Carlo simulation (red line) for 185 kg days. The full energy range of kev is shown on the left and the relevant range for WIMP search ( kev) is shown on the right. Figure 2 shows the gamma-background in the fiducial volume of the EDELWEISS-II detectors compared to the GEANT4 simulation results. The data were collected with the EDELWEISS-II set-up containing 15 germanium detectors of the type described in Ref. [11] with a total exposure of 310 kg days. After a cut on the fiducial volume, data with an exposure of 185 kg days were compared to the simulations. No multiplicity cuts have been applied, i.e. coincident pulses between detectors were included. Multiple-hit events contribute about 30% to the background rate in data and simulations and their rejection does not change the results presented here. Some characteristic peaks are observed in the kev region: 60 Co peaks at 1173 and 1332 kev, 40 K at 1460 kev, 238 kev and 2614 kev from 228 Th (the peaks are linked here to the sub-chain starting with the closest long-lived parent isotope rather than to the gamma-ray emitter). On the right plot of Figure 2 the 46 kev peak from 210 Pb can be seen. The contributions to the gamma background in the low-energy region are presented in Table 2 for two fitting results, corresponding to the minimum and maximum contributions of the thermal cryostat screens. The primary source of gamma background is connected to the U/Th 6
7 Material Table 2: Ionisation event rate in events/kg/day in fiducial volume obtained from simulations. Gamma event rate (events/kg/day) at kev Fit 1 Fit Ra 228 Ra ( 228 Th) 60 Co 40 K Other Total (%) Total (%) radionuclides Ge crystals Ge: (2) 1.6 (2) Detector casings/cuc2 copper Pb: (17) 14 (18) Disks, bars, 10 mk chamber/ Co: (12) 13.5 (17) CuC1 copper 54 Mn: 2.3 Screens 7 to 11/copper Co: (40) 17 (22) 54 Mn: 0.3 Pollution 300K (see text) (27) 29 (37) Modern lead shield (3) 4 (5) Total MC Total data daughters and 60 Co in copper screens 7 to 11 and 10 mk copper parts, which contribute between 39% and 52% to the total gamma-background. The second most important source (between 27% and 37%) is 226 Ra and 228 Ra decays in some detector parts at 300K which must be introduced to match the data. This source (marked as Pollution 300K in Table 2) might be due to radioactivity in cryogenic pipes, bolometer boxes, uncontrolled impurities on the 300K screen or radon still present in the air in the gap between the cryostat and the lead shielding, in spite of the flushing of radon depleted air. The third most important gamma background source is the 210 Pb surface pollution at the level of the detector casings or on the detector s surface (17%). 4. Neutron background The Monte Carlo simulation used the GEANT4 High Precision (HP) model for neutrons with energies below 20 MeV. Elastic and inelastic scattering, capture and fission were included. To check the accuracy of the model, simulations of neutrons from Am-Be source placed inside the Pb shielding on the top of the cryostat, were compared to the measured rate and energy spectrum of nuclear recoils. The source has a neutron intensity of 21 ± 4 neutrons/s and the estimated dead time of the DAQ was 30±10%. The data were collected for about 90 hours and the typical number of detected events above 20 kev after all cuts was about 2000 per crystal giving a statistical error of about 2%. Similar statistics was accumulated in simulations. Figure 3 shows the energy spectrum of nuclear recoils observed from the neutron source and obtained in the simulations. Data have not been corrected for the dead time on this plot so lie below the simulated histogram but the overall shape of the spectra are in good agreement. The ratio of measured-to-simulated event rates above 20 kev after all cuts, corrected for the dead time and averaged over all crystals, was found to be 1.20±0.23, where the error, given at 68% C. L. is dominated by a 19% uncertainty in the source intensity. Statistical and dead time uncertainties are also included. The ratio is consistent with 1 within errors, proving the validity of the geometrical model of the detector and neutron physics in GEANT4. The deviation of the average ratio from 1 may serve as an estimate of the uncertainty of the evaluated neutron rate if the source of background neutrons is located inside the polyethylene shielding. Further tests of the simulation model were done with a strong neutron source giving about neutrons/s, positioned outside the polyethylene and lead shielding. 50 cm of polyethylene should attenuate the fast neutron flux by 5-6 orders of magnitude. The neutron source was placed at several 7
8 Number of events E R, kev Figure 3: Energy spectra of neutrons from the Am-Be source used in the detector calibration. Black histogram data from calibration run with the neutron source; red histogram spectrum obtained in the simulations of neutrons from this source. Data have not been corrected for the detector dead time of DAQ for this particular run which has been found to be 30 ±10%. positions around the shielding to check the shielding model and neutron transport in GEANT4. The thickness of the shielding was not exactly the same for different source positions, the difference being as much as 5 cm of polyethylene. Also some small holes in the shielding are unavoidable due to pipes, readout cables, support structure etc, so special attention was paid to neutrons which could squeeze through these holes inside the shielding. To check the effect of the holes, the neutron source was also positioned close to the existing holes with pipes, cables and support beams. A difference up to a factor of 50 was observed in the data collected with different source positions and similar effect has also been found in the Monte Carlo simulations. For all source positions the rate of detected events after all cuts was found to be in agreement with the simulated rate within a factor of three with a typical uncertainty of 20% for the measurements and simulations. Bearing in mind the challenge of building precise geometry of all shielding and detector components in GEANT4, the agreement between the measured and simulated rate within a factor of three can be considered as reasonably good. This is quite a small difference on a scale of the overall attenuation of the neutron flux by the polyethylene of 5-6 orders of magnitude (depending on the exact thickness of the shielding and neutron energy). A factor of three difference in the neutron rate (if being due to neutron attenuation in polyethylene) corresponds to a thickness of 5 cm of polyethylene. For half of the source positions tested, the difference between the measured and simulated rates does not exceed 50%. The difference of 50% in neutron flux attenuation by 50 cm of polyethylene was found between GEANT4 and MCNPX [14] showing a good agreement between the two codes on an overall scale of 10 6 for the neutron flux attenuation. To estimate the event rate due to neutrons in the EDELWEISS-II experiment, we considered the following materials/components as potential sources of neutrons: cavern walls (rock and concrete), lead (shielding), polyethylene (shielding), copper (cryostat and internal parts), stainless and mild steel (support structure), cables, connectors, electronic parts and other components. The results of the simulations are summarised in Table 3. Neutron spectra were generated using SOURCES4A [13] 8
9 s -1 cm -3 ] -1 Neutron yield [ neutrons MeV Stainless Steel 1 ppb U + 1 ppb Th 1 ppb U - spontaneous fission 1 ppb U - (alpha,n) reactions 1 ppb Th Energy [MeV] Figure 4: Energy spectra of neutrons originated in U and Th decay chains in stainless steel. 1 ppb of U and Th were assumed in the calculations and resulting event spectra were later normalised to the measured concentrations. Contributions from different channels ( 238 U spontaneous fission and (α,n) reactions) from the two decay chains are shown separately, together with the total spectrum. assuming secular equilibrium in the uranium (U) and thorium (Th) decay chains. Further details about neutron production with SOURCES4A for underground experiments can be found in Ref. [15, 16]. Figure 4 shows the energy spectra of neutrons from U/Th decays in stainless steel generated by SOURCES4A. When calculating the neutron-induced event rate, the same cuts have been applied as to the real data: recoil energy threshold of 20 kev, ionisation energy threshold of 3 kev, 90% acceptance in the nuclear recoil band, multiple hit and surface events have been rejected (multiple hit events have been included on the plots). Apart from the mild steel, the radiopurity of different materials was taken from measurements of decay rates with Ge gamma-spectrometers or from mass-spectrometry data on U and Th concentrations. For mild steel we used the same U/Th concentrations as from the stainless steel. Note that even with 5 times higher concentrations of U/Th, the contribution of mild steel components will not exceed 0.2 events for the data reported in Ref. [1]. The measurements of the concentrations of U, Th and K (potassium) in the Modane rock and concrete (rock: 0.84±0.2 ppm U and 2.45±0.2 ppm Th, concrete: 1.9±0.2 ppm U and 1.4±0.2 ppm Th), used in the present work, were initially reported in Ref. [6]. The measurements of the neutron flux at LSM [6] require higher values for U/Th (the normalisation requires an additional factor of 2.3 [7]) than measured in the rock/concrete due to a possible non-uniformity in U/Th abundances or rock composition. The uncertainties in the U/Th concentration, in the neutron transport through polyethylene and additional normalisation factor for the neutron flux lead to a large uncertainty(about a factor of 4.7) in the neutron event rate from the cavern walls. The upper limit on the neutron event rate from the walls is given in Table 3 taking into account this possible error. Since most measurements of U/Th concentrations resulted in upper limits (given at 90% C. L.), normalisation of our simulation results gave upper limits on the neutron-induced event rate in EDELWEISS- II. This gives a significant contribution to the uncertainty in the neutron background event rate. The uncertainty of the neutron flux and spectra calculations using SOURCES4A has been discussed in 9
10 Table 3: Number of background events due to neutrons in EDELWEISS-II in the run detailed in [1]. The column Material refers to the material in each source which contributes most to neutron production. The column Composition gives the chemical composition of the source used to calculate neutron spectra with the abundance of elements (by the number of atoms, not mass) given in brackets. Only elements with the abundance greater than 1% are shown (with the accuracy of 1%). The composition of the mild steel was not known so that of the stainless steel was used instead as giving slightly higher neutron flux than other possible compositions. Neutron yield (columns 4 and 5) is shown as the number of neutrons per gram of material per second per ppb of U and Th concentration. The same cuts as for data have been applied to the simulated events. Source Material Composition (abundance %) Neutron yield in n/g/s/ppb Neutron events U Th (384 kg days) Hall walls Rock H (17), C (8), O (53), Mg (1), <0.01 Al (3), Si (4), Ca (13), Fe (1) Hall walls Concrete H (19), C (11), O (52), <0.1 Mg (1), Si (2), Ca (15) Shielding Polyethylene H (67), C (33) <0.01 Shielding Lead Pb (100) <0.08 Support Stainless steel Cr (17), Mn (0.02), Fe (69), <0.01 Ni (12) Support Mild steel as above <0.04 Warm electronics PCB H (22), B (2), C (19), N (6), ±0.5 O (35), Mg (1), Al (4), Si (8), Ca (3) 1K connectors Aluminium Al (100) ±0.2 Thermal screens, Copper Cu (100) <0.1 crystal supports Coaxial cables PTFE C (33), F (67) <0.5 Crystal holders PTFE C (33), F (67) <0.01 Electrodes Aluminium Al (100) <0.01 Total <3.1 [15, 17] and found to be 20-30% by comparing calculations with different cross-sections for (α, n) reactions and transition probabilities to excited states. The uncertainty due to the neutron transport and geometry model should not exceed 20% (as follows from the agreement between simulations and data with a neutron source positioned within the shielding). The upper limits shown in Table 3 take into account all these uncertainties. The total rate shown in the last row is the sum of all upper limits and is not strictly the upper limit on the total event rate. Bearing in mind that some of the radioactivity measurements gave positive signals, we can also estimate that the lower limit on the nuclear recoil rate is 1.0 events in data reported in Ref. [1]. The neutron background is potentially dominated by neutrons from materials inside the shields, especially cables and electronics. Figure 5 shows an example scatter plot of ionisation yield (ratio of ionisation energy to recoil energy normalised to this ratio for electron recoils) versus recoil energy for simulated nuclear recoils from neutrons originated in the uranium decay chain from contamination in the steel support structure around the main copper vessels neutrons were sampled using the spectrum from SOURCES4A which corresponds to about years of live time for the uranium decay rate of 5 mbq/kg (assuming secular equilibrium). Only events in the fiducial volume of the detectors are shown on the scatter plot. Ionisation yield, Q, has been calculated using the relation Q = 0.16(E rec (kev)) 0.18, where E rec (kev) is the recoil energy. This relation has been proven to be valid for EDELWEISS detectors [11, 18]. To conclude, the neutron rate from radioactivity has been calculated as events (90% C. L.) at kev in the EDELWEISS-II data run if the same cuts are applied to both data and simulations. Muon-induced neutrons are expected to contribute 0.7 events [4]. 5. Expected background in EDELWEISS-III The next stage of the EDELWEISS experiment, EDELWEISS-III is currently under construction at LSM. It will contain 40 Ge detectors (800 g each) with improved configuration of electrodes and higher fraction of fiducial mass per crystal (about 600 g) making the total fiducial mass about 24 kg [19]. Larger target mass requires better purity of materials close to the detectors and additional neutron shielding to reduce the expected background and achieve the projected sensitivity of a few
11 Ionisation Yield % Gammas 90% Neutrons Ionisation Threshold EDELWEISS-II simulations E R, kev Figure 5: Ionisation yield (ratio of ionisation to phonons normalised to this ratio for electron recoils) versus recoil energy for simulated nuclear recoils in EDELWEISS-II from neutrons originated in the uranium decay chain from contamination in the steel support structure around the main copper vessels. Blue curves show the average and the edges of the band which contains 90% of nuclear recoils in one of the crystals as calculated from the experimental resolutions, that were also included in the simulations [1]. Green curves show the band which contains 90% of electron recoils. They appear on the plot because of neutron inelastic scattering and capture resulting in gamma-ray production. The pink curve shows the 3 kev software threshold for ionisation, applied as in real data. Statistics corresponds to about years of live time for the uranium decay rate of 5 mbq/kg. pb. Materials and components which could contribute significantly to the gamma-ray or neutron background rate in EDELWEISS-II are being replaced by their counterparts with better radiopurity, for instance the cryostat screens 7 to 11 and other copper parts at 10 mk (disks supporting the Ge detectors, vertical bars and 10 mk chamber) are made of ultra radiopure NOSV copper [20]. Radioactivity measurements of most new components were done at LSM using low-background gammaray spectrometry. Extensive simulations of gamma-rays and neutrons were carried out for a geometry of EDELWEISS-III with additional neutron shielding and the results were normalised to the measured concentrations of radioactive isotopes. The results of the measurements and simulations are shown in Table 4. For some components, such as cables and connectors, various parts were screened separately using a HPGe detector. We present in Table 4 the data for the parts which contribute the most to the background rate. The uncertainties in the radioactivity levels are given at 90% C. L.. Some measurements gave only upper limits leading to large uncertainties in the expected background rates. Neutron event rates were calculated assuming secular equilibrium in the U/Th decay chains except for 210 Pb sub-chain. The neutron rate is also affected by a large uncertainty in the chemical composition of the component or its part which may contribute to the background. Since a significant fraction of neutrons may come from (α,n) reactions, exact knowledge of the chemical composition of the material is crucial in the estimate of the neutron event rate. However, in some cases, for instance electronics parts, it is not known precisely which particular part is contaminated the most and hence, it is difficult to predict the expected rate of events with high accuracy. We emphasise that we try to avoid placing materials containing elements with high cross-section of (α,n) reactions (low energy threshold), for example fluorine, close to the crystals. As can be seen from Table 4, a large contamination of printed 11
12 Number of events E R, kev Figure 6: Simulated energy spectrum of nuclear recoils in EDELWEISS-III detectors from neutrons originated in the uranium decay chain from contamination in the inner polyethylene shielding. Recoil energy has been calculated as energy deposited in a single crystal and events with all hit multiplicities have been included. Statistics corresponds to about years of live time. circuit boards (PCBs) used in electronics (rows 8 and 9 in Table 4) could compromise the sensitivity of the experiment if crystals were not shielded from their radioactivity by a 14 cm thick lead plate and 10 cm of additional polyethylene shielding. An example nuclear recoil energy spectrum for neutron events from radioactivity (uranium decay chain) in the inner polyethylene shielding and hit multiplicity distribution are shown in Figures 6 and 7, respectively. Multiplicity has been defined as the number of hits in different crystals where at least one hit was in the region of interest: recoil energy kev, ionisation energy > 3 kev, ionisation yield and hit location is within the fiducial volume; other hits have only been required to have an energy higher than 10 kev % of events are single hit events with this selection. Energy spectrum is plotted for all events with any multiplicity. Recoil energy has been calculated as energy deposited in a single crystal. Statistics corresponds to about years of live time. In addition to the components specified in Table 4 we expect to have less than 0.3 neutrons per year from components which were present already in EDELWEISS-II, such as lead shielding, mild and stainless steel support structure etc, bringing the total expected neutron rate to about events per year of running. Decreasing the software energy threshold down to 15 kev will increase the expected neutron rate by 15 20%. By comparing Tables 2 and 4 we can see that the improvement in the background event rate induced by gamma-rays as measured per unit mass and unit exposure time, will be up to a factor of 6. Even in the worst possible scenario of all contaminations being close to the 90% C. L. upper limits (a factor of 2 improvement in gamma-induced event rate), we expect that better performance of the new fiducial inter-digitized (FID) detectors compared to the old type ID detectors will allow us to reach the projected sensitivity of a few 10 9 pb to WIMP-nucleon cross-section. 12
13 13 Table 4: Radioactive contaminations in materials of the EDELWEISS-III set-up. All contaminations have been assessed by gamma-ray spectrometry at LSM, except for NOSV copper of thermal screens that have been taken from the measurements reported in [20]. The last two columns give the expected gamma-induced background in events/kg/day at kev and neutron-induced background in a year of running in 24 kg of fiducial mass. For 15 kev threshold the gamma background will change by less than 3% whereas the neutron background will increase by about 15 20%. The first 5 rows with data show the materials positioned close to the crystals so crystals are directly exposed to the radiation from these components. The next 3 rows show the materials below the lead plate and polyethylene beneath the detectors. A small gamma rate from warm electronics is due to the additional lead which shields the crystals from the gamma radiation. The gamma-induced rate is given for all events within the fiducial volume without excluding coincidences between different crystals. For neutron-induced rate the coincidences were excluded assuming the threshold for a second hit of 10 kev (35-40% of events are single hit events with this selection). Component Material Mass Radioactivity in materials (mbq/kg) Gammas Neutrons (kg) 226 Ra 228 Th 210 Pb 40 K 60 Co (kg days) 1 Events/year Cables Apical, Cu ±15 <50 346± ±126 < Connectors Delrin, brass ±20 < ± ±220 < Screws Brass ±1.3 <3 <100 <40 <3 <1 <0.003 Screens, support Cu 500 <0.016 <0.012 <0.11 <0.018 <7 <0.01 Shielding CH ± ±0.07 <3 <1 < Connectors Al, resin ±9 158±6 743±48 129±33 < Cables PTFE 1 <35 <28 190±40 440±110 <19 <1 <0.1 Cold electronics PCB ± ± ± ±1200 < Warm electronics PCB ± ± ± ± < Total Decay rates for warm electronics are given for the whole set (not in mbq/kg).
14 Number of events Event multiplicity Figure 7: Hit multiplicity distribution for nuclear recoils in EDELWEISS-III detectors from neutrons originated in the uranium decay chain from contamination in the inner polyethylene shielding. Statistics corresponds to about years of live time. See text for details. Since single nuclear recoil events from neutrons cannot be rejected by any discrimination technique, special measures have been taken in the new design to reduce possible background from neutrons, specifically, an additional polyethylene shielding will be installed in EDELWEISS-III. Our simulations (see Table 4) show that this shielding will suppress the neutron background by more than an order of magnitude (per unit target mass) compared to the EDELWEISS-II setup. The neutron background givenin Table 4correspondstothe rateper unit mass and exposureof( ) 10 4 events/kg/day in EDELWEISS-III comparedto ( ) 10 3 events/kg/dayin EDELWEISS-II. An improvement by at least an order of magnitude will allow us to achieve the projected sensitivity with about 3000 kg days of statistics with EDELWEISS-III. 6. Conclusions An extensive study of the gamma and neutron background in the EDELWEISS experiment has been performed, based on Monte Carlo simulations combined with radiopurity data. The primary source of gamma background in EDELWEISS-II is the copper from the cryostat screens and 10 mk parts. The neutron background is potentially dominated by neutrons produced by α-n reactions in materials inside the shields, in particular cables and electronics. The calculated neutron rate from radioactivity of events (90% C. L.) at keVin the EDELWEISS-IIdata run togetherwith the expected upper limit on the misidentified gamma-ray events ( 0.9), surface betas ( 0.3) [1], and muoninduced neutrons ( 0.7) [4], do not contradict 5 observed events in nuclear recoil band [1]. The background studies performed in the present work have contributed to the design of the next stage of the experiment, EDELWEISS-III. New cryostat screens and 10 mk parts will be built from ultrapure copper and an inner polyethylene shielding against neutrons from materials inside the external shielding will be installed. The expected gamma-ray and neutron induced background rates from 14
15 radioactivity in EDELWEISS-III at kev are events/kg/day and events in 40 detectors per year, respectively. With these improvements and the projected increase by an order of magnitude of the detector mass, the goal is to soon probe the range of spin-independent WIMP-nucleon cross-sections down to a few 10 9 pb. Acknowledgments The help of the technical staff of the Laboratoire Souterrain de Modane is gratefully acknowledged. Matthias Laubenstein has kindly measured the copper of type CuC2 using the GeMPI detector at the Laboratori Nazionale de Gran Sasso, LNGS, developed by the Max-Planck-Institut fuer Kernphysik (MPIK) in Heidelberg. The EDELWEISS project is supported in part by the Agence Nationale pour la Recherche (France) under contract ANR-10-BLAN , the Russian Foundation for Basic Research (Russia) and the Science and Technology Facilities Council (UK, grants ST/I003371/1, ST/I00338X/1, ST/J000671/1, ST/J000663/1, ST/K003186/1, ST/K006444/1, ST/K003151/1). Background studies for dark matter search are funded in part by the German ministry of science and education (BMBF) within the Verbundforschung Astroteilchenphysik grant 05A11VK2. References [1] E. Armengaud et al. (The EDELWEISS Collaboration). Phys. Lett. B, 702, 329 (2011). [2] A. Broniatowski et al. J. Low Temp. Phys., 151, 830 (2008). [3] A. Broniatowski et al. (The EDELWEISS Collaboration). Physics Letters B, 681, 305 (2009). [4] B. Schmidt et al. (The EDELWEISS Collaboration). Astroparticle Physics, 44, 28 (2013). [5] V. Yu. Kozlov et al. Astroparticle Phys., 34, 97 (2010). [6] V. Chazal et al. Astroparticle Phys., 9, 163 (1998). [7] S. Fiorucci et al. (The EDELWEISS Collaboration). Astroparticle Phys., 28, 143 (2007). [8] G. Heusser, M. Laubenstein and H. Neder. Radionuclides in the Environment: International Conference on Isotopes in Environmental Studies (Aquatic Forum 2004, October, Monaco), ed. by P. Povinec, J. A. Sanchez-Cabeza, Radioactivity in the environment, (2006). [9] X.-F. Navick et al. Nucl. Instrum. & Meth. A, 444, 361 (2000). [10] S. Agostinelli et al. Nucl. Instrum. & Meth. A, 506, 250 (2003). [11] O. Martineau et al. (The EDELWEISS Collaboration). Nucl. Instrum. & Meth. A, 530, 426 (2004). [12] [13] W. B. Wilson et al. SOURCES4A, Techical Report LA MS, Los Alamos (1999). [14] R. Lemrani et al. Nucl. Instrum. & Meth. A, 560, 454 (2006). [15] V. Tomasello, V. A. Kudryavtsev, M. Robinson. Nucl. Instrum. & Meth. A, 595, 431 (2008). [16] V. Tomasello, M. Robinson, V. A. Kudryavtsev. Astroparticle Phys, 34, 70 (2010). [17] M. J. Carson et al. Astroparticle Phys, 21, 667 (2004). [18] P. D. Stefano et al. Astropart. Phys., 14, 329 (2001). [19] E. Armengaud (for the EDELWEISS Collaboration). Talk at the 12th International Conference on Topics in Astroparticle and Underground Physics (TAUP2011, Munich, 5-9 September 2011); [20] M. Laubenstein et al. Applied Radiation and Isotopes, 61, 167 (2004). 15
Edelweiss-II : status and first results A new generation of background-free bolometers for WIMP search
Edelweiss-II : status and first results A new generation of background-free bolometers for WIMP search From EDWI to EDW II New ID detectors Some current results Outlook G. Gerbier CEA Saclay, IRFU, France
More informationBackground simulations and shielding calculations
Background simulations and shielding calculations Vitaly A. Kudryavtsev University of Sheffield Contributions from many others Outline Note 1: results are relevant to many experiments and techniques (mainly
More informationLow energy neutron propagation in MCNPX and GEANT4
Low energy neutron propagation in and R. Lemrani a M. Robinson b V. A. Kudryavtsev b M. De Jesus c G. Gerbier a N. J. C. Spooner b arxiv:hep-ex/06030 v1 17 Jan 2006 a DAPNIA-SPP, CEA-Saclay, Gif-Sur-Yvette,
More informationLatest results of EDELWEISS II
Latest results of EDELWEISS II Ana Torrentó CEA/IRFU/SPP Saclay Rencontres de Moriond 2011 «EW and Unified Theories» WIMP search Motivated by the «WIMP miracle» Very small rate of WIMPnucleus scattering
More informationThe EDELWEISS DM search Phase II to Phase III
The EDELWEISS DM search Phase II to Phase III Adam Cox Karlsruhe Institute for Technology (KIT) on behalf of the EDELWEISS Collaboration CEA, Saclay (IRFU and IRAMIS) IPNL (CNRS/IN2P3 and Université de
More informationNeutron- and muoninduced. underground physics experiments. L. Pandola, V. Tomasello and V. Kudryavtsev. for the JRA1 and N3 simulation groups
Neutron- and muoninduced background in underground physics experiments L. Pandola, V. Tomasello and V. Kudryavtsev for the JRA1 and N3 simulation groups ILIAS 4 th Annual Meeting, Chambery, 2007 ILIAS
More informationStatus of the EDELWEISS Dark Matter search
Status of the EDELWEISS Dark Matter search KIT Institute Centre for Particle Nuclear and Physics Astroparticle Physics KIT University of the State of Baden-Wuerttemberg and National Research Center of
More informationDirekte Suche nach Dark Matter
Direkte Suche nach Dark Matter WIMP über elastische Streuung an Kernen HDMS Ge 10% energy Ionization Ge, Si Edelweiss, CDMS liquid Xe Zeplin-2, US-Xenon NaI, liqu.xe Target Light 1% energy fastest no surface
More informationNeutron background in underground particle astrophysics experiments
Neutron background in underground particle astrophysics experiments V. A. Kudryavtsev Department of Physics and Astronomy University of Sheffield for ILIAS and the UK Dark Matter Collaboration LRT2006-01/10/2006
More informationBackgrounds and Sensitivity Expectations for XENON100
Backgrounds and Sensitivity Expectations for XENON100 IDM08, Stockholm, August 19, 2008 Laura Baudis University of Zurich For the XENON100 Collaboration LNGS collaboration meeting, Oct. 2007 1 ??? The
More informationNeutron background in large-scale xenon detectors for dark matter searches
Astroparticle Physics xxx (2004) xxx xxx www.elsevier.com/locate/astropart Neutron background in large-scale xenon detectors for dark matter searches M.J. Carson, J.C. Davies, E. Daw, R.J. Hollingworth,
More informationarxiv: v1 [physics.ins-det] 26 May 2015
GeMSE: A new Low-Background Facility for Meteorite and Material Screening arxiv:1505.07015v1 [physics.ins-det] 26 May 2015 M. v. Sivers 1, B. A. Hofmann 2,3, A. V. Rosén 2, and M. Schumann 1 1 Albert Einstein
More informationarxiv:astro-ph/ v1 24 Jun 2004
LATEST RESULTS OF THE EDELWEISS EXPERIMENT arxiv:astro-ph/46537v 24 Jun 24 V. SANGLARD for the Edelweiss collaboration Institut de Physique Nucléaire de Lyon, 4 rue Enrico Fermi, 69622 Villeurbanne, France
More informationarxiv: v1 [hep-ex] 15 Dec 2009
The expected background spectrum in NaI dark matter detectors and the DAMA result V. A. Kudryavtsev 1, M. Robinson, N. J. C. Spooner Department of Physics and Astronomy, University of Sheffield, Sheffield,
More informationThe XENON Dark Matter Project: Status of the XENON100 Phase. Elena Aprile Columbia University
The XENON Dark Matter Project: Status of the XENON100 Phase Elena Aprile Columbia University 8th UCLA Symposium Marina del Rey, Feb 22, 2008 The XENON Dark Matter Phased Program Detect WIMPS through their
More informationResults from 730 kg days of the CRESST-II Dark Matter Search
Results from 730 kg days of the CRESST-II Dark Matter Search Federica Petricca on behalf of the CRESST collaboration: Max-Planck-Institut für Physik, München TU München University of Oxford Universität
More informationIdentification of backgrounds in the EDELWEISS-I dark matter search experiment
Identification of backgrounds in the EDELWEISS-I dark matter search experiment S. Fiorucci, Alain Benoit, L. Berge, J. Blumer, A. Broniatowski, B. Censier, A. Chantelauze, M. Chapellier, G. Chardin, S.
More informationStudies of the XENON100 Electromagnetic Background
Studies of the XENON100 Electromagnetic Background Daniel Mayani Physik-Institut University of Zurich PhD Seminar PSI, August 26-27, 2015 Searching for elusive particles The main challenge for experiments
More informationThe XENON100 Dark Matter Experiment
The XENON0 Dark Matter Experiment Marc Schumann 1, Eirini Tziaferi 2 for the XENON0 collaboration 1 Rice University, 60 Main St., Houston TX, USA 2 University of Zürich, Winterthurerstr. 190, Zürich, Switzerland
More informationBackground Modeling and Materials Screening for the LUX and LZ Detectors. David Malling Brown University LUX Collaboration AARM Meeting February 2011
Background Modeling and Materials Screening for the LUX and LZ Detectors David Malling Brown University LUX Collaboration AARM Meeting February 2011 1 Summary LUX screening program limits background contributions
More informationNEUTRON BACKGROUND STUDIES FOR THE EDELWEISS WIMP SEARCH
NEUTRON BACKGROUND STUDIES FOR THE EDELWEISS WIMP SEARCH G. CHARDIN AND G. GERBIER FOR THE EDELWEISS COLLABORATION DSM/DAPNIA/SPP, CEA/Saclay. F-91191 Gif-sur-Yvette Cedex, France E-mail: gabriel.chardin@cea.fr
More informationThe XENON100 Dark Matter Experiment at LNGS: Status and Sensitivity
The XENON100 Dark Matter Experiment at LNGS: Status and Sensitivity Elena Aprile (on behalf of the XENON Collaboration) Columbia University,Physics Department, New York,NY, USA E-mail: age@astro.columbia.edu
More informationUCLA Dark Matter 2014 Symposium. Origins and Distributions of the Backgrounds. 15 min
S. Fiorucci Brown University UCLA Dark Matter 2014 Symposium Origins and Distributions of the Backgrounds 15 min What is a signal for LUX? Nuclear recoil Single scatter Signal Low energy, typically < 25
More informationStatus of the GERDA experiment
Status of the GERDA experiment Hardy Simgen Max-Planck-Institute for Nuclear Physics Heidelberg The GERDA experiment Next generation 76 Ge double beta decay experiment at Gran Sasso. Basic idea: Operation
More informationBackground optimization for a new spherical gas detector for very light WIMP detection
Background optimization for a new spherical gas detector for very light WIMP detection a, I. Giomataris b, G. Gerbier b, J. Derré b, M. Gros b, P. Magnier b, D. Jourde b, E.Bougamont b, X-F. Navick b,
More informationTechnical Specifications and Requirements on Direct detection for Dark Matter Searches
Technical Specifications and Requirements on Direct detection for Dark Matter Searches Jin Li THU/IHEP Symposium of the Sino-German GDT Cooperation 04/08/2013 Tübingen Outline Introduction Direct detection
More informationDARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS
DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update María Luisa Sarsa (Universidad de Zaragoza) On behalf of ANAIS & ROSEBUD Collaborations OUTLINE ANAIS INTRODUCTION AND EXPERIMENTAL GOALS
More informationThe Search for Dark Matter with the XENON Experiment
The Search for Dark Matter with the XENON Experiment Elena Aprile Columbia University Paris TPC Workshop December 19, 2008 World Wide Dark Matter Searches Yangyang KIMS Homestake LUX SNOLAB DEAP/CLEAN
More information- The CONUS Experiment - COherent elastic NeUtrino nucleus Scattering
- The CONUS Experiment - COherent elastic NeUtrino nucleus Scattering C. Buck, J. Hakenmüller, G. Heusser, M. Lindner, W. Maneschg, T. Rink, H. Strecker, T. Schierhuber and V. Wagner Max-Planck-Institut
More informationLooking for WIMPs with EDELWEISS. Results and status of EDW I Prospects for EDW II + DAMA /LIBRA: brief status/future
Looking for WIMPs with EDELWEISS Results and status of EDW I Prospects for EDW II + DAMA /LIBRA: brief status/future G. Gerbier CEA/Saclay/DAPNIA G. Gerbier NESS 2002 1 The Edelweiss Collaboration CEA-
More informationBackground Characterization and Rejection in the LZ Detector. David Malling Brown University IDM 2012 July 25, 2012
Background Characterization and Rejection in the LZ Detector David Malling Brown University IDM 2012 July 25, 2012 LZ Construction 2 Background Sources Ti cryostats 1500 kg
More informationXENONNT AND BEYOND. Hardy Simgen. WIN 2015 MPIK Heidelberg. Max-Planck-Institut für Kernphysik Heidelberg
XENONNT AND BEYOND Hardy Simgen Max-Planck-Institut für Kernphysik Heidelberg WIN 2015 MPIK Heidelberg THE XENON PROGRAM FOR DIRECT DARK MATTER SEARCH 1 THE PRESENT: XENON1T! LXe TPC under construction
More informationSTATUS OF THE EDELWEISS EXPERIMENT
Ó³ Ÿ. 2001. º3[106] Particles and Nuclei, Letters. 2001. No.3[106] Š 539.12 STATUS OF THE EDELWEISS EXPERIMENT M.Stern Institut de Physique Nucleaire de Lyon and Universite Claude Bernard, Lyon-1, IN2P3-CNRS,
More informationBackground Studies for the XENON100 Experiment. Alexander Kish Physics Institute, University of Zürich Doktorandenseminar August 30, 2010 UZH
Background Studies for the XENON100 Experiment Alexander Kish Physics Institute, University of Zürich Doktorandenseminar August 30, 2010 UZH The XENON dark matter search program Target Volume 62 kg Total
More informationNeutron background studies for
Neutron background studies for Edelweiss programs Introducing ETNomSiQ working group - Past measurements - Monte Carlo studies - Program of measurements and protections for EDELW II G. Gerbier CEA/Saclay,
More informationThe GERmanium Detector Array
The GERmanium Detector Array n n ν=v p e - e - p Outline: Exp. issues of 0νββ-decay of 76 Ge Concept of GERDA Status of the experiment Summary and conclusions Kevin Kröninger (Max-Planck-Institut für Physik,
More informationDark matter search with the SABRE experiment
Dark matter search with the SABRE experiment Giulia D Imperio* for the SABRE collaboration *INFN Roma 1 25-07-2017 TAUP 2017 Sudbury, Canada 1 Dark matter detection through annual modulation WIMP is one
More informationDesign, Construction, Operation, and Simulation of a Radioactivity Assay Chamber
Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber Wesley Ketchum and Abe Reddy EWI Group, UW REU 2006 Outline Neutrino Physics Background Double Beta Decay and the Majorana
More informationGamma background measurements in the Boulby Underground Laboratory
J Radioanal Nucl Chem (2013) 298:1483 1489 DOI 10.1007/s10967-013-2540-9 Gamma background measurements in the Boulby Underground Laboratory Dariusz Malczewski Jan Kisiel Jerzy Dorda Received: 1 March 2013
More informationThe 46g BGO bolometer
Nature, 3 The g BGO bolometer 1 Photograph of the heat [g BGO] and light [Ge; =5 mm] bolometers: see Fig. 1c for description Current events: Amplification gains: 8, (heat channel) &, (light channel). The
More informationPoS(EPS-HEP2017)074. Darkside Status and Prospects. Charles Jeff Martoff Temple University
Temple University E-mail: cmartoff@gmail.com The DarkSide Dark Matter Search Program is a direct-detection search for dark matter using a Liquid Argon Time Projection Chamber. The detector is designed
More informationDirect Dark Matter and Axion Detection with CUORE
Direct Dark Matter and Axion Detection with CUORE Marco Vignati University of Rome La Sapienza & INFN Rome on behalf of the CUORE collaboration Panic 11, July 5, MIT 988 TeO crystals Ton scale bolometric
More informationScintillating bolometers for the LUCIFER project. Luca Pattavina INFN-Laboratori Nazionali del Gran Sasso
Scintillating bolometers for the LUCIFER project Luca Pattavina INFN-Laboratori Nazionali del Gran Sasso luca.pattavina@lngs.infn.it 1 Outline - Scintillating bolometers - basics - potential - The LUCIFER
More informationSearch for low-mass WIMPs with Spherical Detectors : NEWS-LSM and NEWS-SNO
Search for low-mass WIMPs with Spherical Detectors : NEWS-LSM and NEWS-SNO G. Gerbier 1 for the NEWS collaboration 2, 1 Queen s University, Physics Department, Kingston, Canada 2 New Experiments With Spheres
More informationThe EDELWEISS III Experiment Status
Quentin ARNAUD for the Edelweiss Collaboration The EDELWEISS III Experiment Status Les Rencontres de Moriond 2014 Cosmology Session 27/03/2014 Dark Matter Search Evidences for Dark Matter Galaxy Clusters
More informationarxiv:astro-ph/ v3 26 May 2005
LYCEN 25-5 Final results of the EDELWEISS-I dark matter search with cryogenic heat-and-ionization Ge detectors V. Sanglard,, A. Benoit, 2 L. Bergé, 3 J. Blümer, 4,5 A. Broniatowski, 3 B. Censier, 3 arxiv:astro-ph/53265v3
More informationarxiv: v1 [astro-ph.co] 28 Feb 2013
Muon-induced background in the EDELWEISS dark matter search arxiv:132.7112v1 [astro-ph.co] 28 Feb 213 The EDELWEISS collaboration, B. Schmidt, a), E. Armengaud b), C. Augier c), A. Benoit d), L. Bergé
More informationDOUBLE BETA DECAY OF 106 Cd - EXPERIMENT TGV (Telescope Germanium Vertical) EXPERIMENT SPT (Silicon Pixel Telescope)
DOUBLE BETA DECAY OF 106 Cd - EXPERIMENT TGV (Telescope Germanium Vertical) EXPERIMENT SPT (Silicon Pixel Telescope) I. Štekl (IEAP CTU in Prague) on behalf of TGV collaboration CSNSM Orsay, France CU
More informationSchool of Mathematics and Physics, Fujian University of Technology, Fuzhou , China
Evaluation of the neutron background in cryogenic Germanium target for WIMP direct detection when using a reactor neutrino detector as a neutron veto system arxiv:1205.0428v4 [astro-ph.im] 3 Dec 2015 Ye
More informationMeasurement of 39 Ar in Underground Argon for Dark Matter Experiments
Measurement of 39 Ar in Underground Argon for Dark Matter Experiments Jingke Xu Princeton University June 7 th, 2013 1 Evidences for Dark Matter Rotation Curve Gravitational Lensing CMB Power Spectrum
More informationInvestigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay
11 November 1999 Ž. Physics Letters B 467 1999 132 136 Investigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay N.J.T. Smith a, P.F.
More informationEsperimenti bolometrici al Gran Sasso: CUORE e CRESST
Esperimenti bolometrici al Gran Sasso: CUORE e CRESST Marco Vignati 24 Ottobre 2011 0νDBD in Theory Nuclear process: (A,Z) (A,Z+2) + 2 e - Can only happen if lepton number is not conserved. The decay probability
More informationCryogenic Dark Matter Search in Europe
Cryogenic Dark Matter Search in Europe Wolfgang Rau Queen s University Kingston, Canada Introduction W. Rau 2 Search for nuclear recoils (NR) from WIMP interactions. Background mostly electron recoils
More informationCosmogenic and primordial radioisotopes in copper bricks shortly exposed to cosmic rays
Journal of Physics: Conference Series PAPER OPEN ACCESS Cosmogenic and primordial radioisotopes in copper bricks shortly exposed to cosmic rays To cite this article: I Coarasa et al 216 J. Phys.: Conf.
More informationBackground and sensitivity predictions for XENON1T
Background and sensitivity predictions for XENON1T Marco Selvi INFN - Sezione di Bologna (on behalf of the XENON collaboration) Feb 19 th 016, UCLA Dark Matter 016 1 Outline Description of the detector;
More informationStudy well-shaped germanium detectors for lowbackground
Journal of Physics: Conference Series PAPER OPEN ACCESS Study well-shaped germanium detectors for lowbackground counting To cite this article: W-Z Wei et al 2015 J. Phys.: Conf. Ser. 606 012019 View the
More informationFirst tests of the big volume ultra low background gamma spectrometer
First tests of the big volume ultra low background gamma spectrometer N. Todorović,, D. MrđaM rđa,, I. Bikit, M. Vesković,, S. Forkapić,, J. Slivka Departman za fiziku, PMF, Novi Sad 1. Introduction Even
More informationD. Medvedev GEMMA and vgen Nalchik, June 6, Investigation of neutrino properties with Ge detectors on KNPP
D. Medvedev GEMMA and vgen Nalchik, June 6, 2017 ν Investigation of neutrino properties with Ge detectors on KNPP Kalininskaya Nuclear Power Plant (KNPP) GEMMA vgen DANSS Udomlya, ~ 280 km to the North
More informationDARWIN: dark matter WIMP search with noble liquids
DARWIN: dark matter WIMP search with noble liquids Physik Institut, University of Zurich E-mail: laura.baudis@physik.uzh.ch DARWIN (DARk matter WImp search with Noble liquids) is an R&D and design study
More informationCosmogenic background for the GERDA experiment. Luciano Pandola INFN, Laboratori del Gran Sasso, Italy
Cosmogenic background for the GERDA experiment Luciano Pandola INFN, Laboratori del Gran Sasso, Italy Cosmogenic Activity and Background Workshop, Berkeley April 15 th, 2011 GERDA experiment at LNGS The
More informationNeutrinoless double beta decay with CUPID-Mo
Neutrinoless double beta decay with CUPID-Mo Pia Loaiza ANDES workshop, Sao Paulo, 4-6 August 2018 Two neutrino double beta decay Certain isotopes are forbidden from decaying through standard beta decay
More informationRivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso
Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso 1 RADIOCHEMICAL Integrated in energy and time CHERENKOV Less than 0.01% of the solar neutrino flux is been measured in
More informationRecent results from the UK Dark Matter Search at Boulby Mine.
Recent results from the UK Dark Matter Search at Boulby Mine. Nigel Smith Rutherford Appleton Laboratory on behalf of the UK Dark Matter Collaboration (Imperial College, Sheffield, RAL) NaI scintillation
More informationSimulations and other stuff
Simulations and other stuff Vitaly A. Kudryavtsev University of Sheffield Contributions from many others Outline Muon generators: MUSIC, MUSUN. Neutrons from muons. Neutrons from radioactivity. Some notes
More informationDarkSide-50: performance and results from the first atmospheric argon run
DarkSide-50: performance and results from the first atmospheric argon run Yann Guardincerri on behalf of the DarkSide Collaboration August 27th, 2014 1 / 21 DarkSide Direct detection search for WIMP dark
More informationThe next generation dark matter hunter: XENON1T status and perspective
The next generation dark matter hunter: XENON1T status and perspective A. Rizzo a on behalf of the XENON Collaboration Department of Astrophysics, Columbia University in the City of New York, USA Abstract.
More informationThe SciCryo Project and Cryogenic Scintillation of Al_2O_3 for Dark Matter
The SciCryo Project and Cryogenic Scintillation of Al_2O_3 for Dark Matter P. Di Stefano, N. Coron, P. De Marcillac, C. Dujardin, M. Luca, F. Petricca, F. Proebst, S. Vanzetto, M.-A. Verdier To cite this
More informationSimulations, backgrounds, and uncertainties in PICO-2L. Alan Robinson May 20, 2015 AARM, Rapid City South Dakota
Simulations, backgrounds, and uncertainties in Alan Robinson May 20, 2015 AARM, Rapid City South Dakota Calibrations of Nuclear Recoils in C3F8 Calibration Slide 2/33 CAM 2013 Aug 16, 2013 Simulations
More informationGERDA experiment A search for neutrinoless double beta decay. Roberto Santorelli (Physik-Institut der Universität Zürich)
GERDA experiment A search for neutrinoless double beta decay Roberto Santorelli (Physik-Institut der Universität Zürich) on behalf of the GERDA collaboration ÖPG/SPS/ÖGAA meeting 04/09/09 Neutrinos mixing
More information=> Ωmatter >> Ωbaryon
Cryogenic Detectors Direct Search Cryogenic Detectors CRESST Project Cosmic Microwave Background Matter-Density Ωmatter Anisotropy: Angular scale => geometry, Ωtot Wilkinson Microwave Anisotropy Probe
More informationThe Dortmund Low Background Facility Low-Background Gamma Ray Spectrometry with an Artificial Overburden
The Dortmund Low Background Facility Low-Background Gamma Ray Spectrometry with an Artificial Overburden Holger Gastrich a, Claus Gößling a, Reiner Klingenberg a, Kevin Kröninger a, Till Neddermann a,
More informationTHE CRYOGENIC UNDERGROUND OBSERVATORY FOR RARE EVENTS: STATUS AND PROSPECTS
THE CRYOGENIC UNDERGROUND OBSERVATORY FOR RARE EVENTS: STATUS AND PROSPECTS Eric B. Norman Dept. of Nuclear Engineering Univ. of California, Berkeley, CA U. S. A. Recent results in n physics Neutrinos
More informationThe COSINUS project. development of new NaI- based detectors for dark ma6er search. STATUS report Karoline Schäffner
The COSINUS project development of new NaI- based detectors for dark ma6er search STATUS report 2016 Karoline Schäffner SCATTERING SCENARIO Dark matter particles scatter off nuclei elastically coherently:
More informationGERDA: The GERmanium Detector Array for the search for neutrinoless decays of 76 Ge. Allen Caldwell Max-Planck-Institut für Physik
GERDA: The GERmanium Detector Array for the search for neutrinoless decays of 76 Ge Allen Caldwell Max-Planck-Institut für Physik What we know Mass Scale NORMAL INVERTED m 12 2 known m 13 2 known Mixing
More informationSensitivity and Backgrounds of the LUX Dark Matter Search
Sensitivity and Backgrounds of the LUX Dark Matter Search 1 LUX Goal: Direct Detection of Dark Matter WMAP 5-year data (2008) gives matter densities (Ω) based on best fit to Λ-CDM cosmological model: Ω
More informationNeutron flux measurement using fast-neutron activation of 12 B and 12 N isotopes in hydrocarbonate scintillators
Neutron flux measurement using fast-neutron activation of 12 B and 12 N isotopes in hydrocarbonate scintillators M. M. Boliev E-mail: kchkrv@rambler.ru Yu. F. Novoseltsev R. V. Novoseltseva V. B. Petkov
More informationLow Background Counting At SNOLAB
Low Background Counting At SNOLAB Ian Lawson Collaboration Meeting Minneapolis, Minnesota, June 22-23, 212 1 Outline SNOLAB and description of the SNOLAB Low Background Gamma Counting System Other material
More informationMeasurements of liquid xenon s response to low-energy particle interactions
Measurements of liquid xenon s response to low-energy particle interactions Payam Pakarha Supervised by: Prof. L. Baudis May 5, 2013 1 / 37 Outline introduction Direct Dark Matter searches XENON experiment
More informationLow Background Experiments and Material Assay. Tessa Johnson NSSC Summer School July 2016
Low Background Experiments and Material Assay Tessa Johnson NSSC Summer School July 2016 Outline How do we detect particles? Some interesting questions relating to particle physics How can particle detection
More informationANAIS: Status and prospects
ANAIS: Status and prospects J. Amaré, S. Cebrián, C. Cuesta, E. García, C. Ginestra, M. Martínez 1, M.A. Oliván, Y. Ortigoza, A. Ortiz de Solórzano, C. Pobes, J. Puimedón, M.L. Sarsa, J.A. Villar, P. Villar
More informationUltra-Low Background Counting and Assay Studies At SNOLAB
Ultra-Low Background Counting and Assay Studies At SNOLAB Ian Lawson SNOLAB 2015 CAP Congress University of Alberta 1 Outline Motivation for Low Background Counters Advantages of being deep Current Facilities
More informationThe Gerda Experiment for the Search of Neutrinoless Double Beta Decay
The Gerda Experiment for the Search of Neutrinoless Double Beta Decay Manuel Walter for the Gerda collaboration Physik-Institut, Universität Zürich, 8057 Zürich, Switzerland DOI: will be assigned The Gerda
More informationCryogenic Detectors Direct Dark Matter Search. Dark Matter
Cryogenic Detectors Direct Search Matter in the Universe - Composition ν too light => most of the is cold Ωmat = 0.27 0.04 u d of so far unknown weakly interacting, massive particles WIMPs normal baryonic
More informationCross-section Measurements of Relativistic Deuteron Reactions on Copper by Activation Method
Nuclear Physics Institute, Academy of Sciences of the Czech Republic Department of Nuclear Reactors, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague Cross-section
More informationBackground rejection techniques in Germanium 0νββ-decay experiments. ν=v
Background rejection techniques in Germanium 0νββ-decay experiments n p ν=v n eep II. Physikalisches Institut Universität Göttingen Institutsseminar des Inst. für Kern- und Teilchenphysik, Outline Neutrinos
More informationCryodetectors, CRESST and Background
Cryodetectors, CRESST and Background A cryogenic detector for Dark Matter with heat (phonon) readout and light (scintillation) readout MPI, TUM, Oxford, Tübingen, LNGS What we re looking for: M W imp =
More informationarxiv:astro-ph/ v1 15 Feb 2005
The XENON Dark Matter Experiment Elena Aprile (on behalf of the XENON collaboration) Physics Department and Columbia Astrophysics Laboratory, Columbia University, New York, New York 10027 age@astro.columbia.edu
More informationStatus of Cuore experiment and last results from Cuoricino
Status of Cuore experiment and last results from Cuoricino on behalf of the Cuore collaboration Istituto Nazionale di Fisica Nucleare, Genova E-mail: elena.guardincerri@ge.infn.it CUORE is a cryogenic-bolometer
More informationDark Matter Detection and the XENON Experiment. 1 Abstract. 2 Introduction
Dark Matter Detection and the XENON Experiment Elena Aprile Physics Department and Columbia Astrophysics Laboratory Columbia University New York, New York 10027 1 Abstract Observations on all fronts strongly
More informationGamma background measurements in the Laboratoire Souterrain de Modane
J Radioanal Nucl Chem DOI 10.1007/s10967-011-1497-9 Gamma background measurements in the Laboratoire Souterrain de Modane Dariusz Malczewski Jan Kisiel Jerzy Dorda Received: 5 October 2011 Ó The Author(s)
More informationarxiv: v1 [physics.ins-det] 4 Nov 2017
arxiv:1711.01488v1 [physics.ins-det] 4 Nov 017 Current status and projected sensitivity of COSINE-0 WG Thompson, on behalf of the COSINE-0 Collaboration Department of Physics, Yale University, New Haven,
More informationLight dark matter search with a spherical proportional counter
Light dark matter search with a spherical proportional counter I. Giomataris, CEA-Irfu-France NEWS (New Experiment for Wimps with Sphere) Main goal: search for ultra-light WIMP 100 MeV 10 GeV Using the
More informationUltra-Low Background Measurement Capabilities At SNOLAB
Ultra-Low Background Measurement Capabilities At SNOLAB Ian Lawson SNOLAB Greater Sudbury, Canada Torino, Italy 1 Brief Outline Motivation for low background counters Advantages of being deep Current facilities
More informationStatus of KIMS-NaI experiment
Status of KIMS-NaI experiment Hyun Su Lee Institute for Basic Science, Korea On behalf of the KIMS Collaboration XIV International Conference on Topics in Astroparticle and Underground Physics KIMS-NaI
More informationXMASS 1.5, the next step of the XMASS experiment
1,2 for the XMASS collaboration 1 Kamioka Observatory, Institute for Cosmic Ray Research, the University of Tokyo, Higashi-Mozumi, Kamioka, Hida, Gifu 506-1205, Japan, 2 Kavli Institute for Physics and
More informationStatus of the CUORE and CUORE-0 experiments at Gran Sasso
Status of the CUORE and CUORE-0 experiments at Gran Sasso S. Di Domizio INFN and University of Genova for the CUORE collaboration Weak Interactions and Neutrinos Natal, September 19 2013 Neutrinoless double
More informationcryogenic calorimeter with particle identification for double beta decay search
cryogenic calorimeter with particle identification for double beta decay search Cuore Upgrade with Particle IDentification In the middle of 2015 INFN decided to support CUPID activity to develop: CUPID-0:
More informationDouble Beta Present Activities in Europe
APPEAL Workshop 19-21 February 2007, Japan Double Beta Present Activities in Europe Xavier Sarazin Laboratoire de l Accélérateur Linéaire Orsay France Germanium detector Bolometers CdZnTe semiconductors
More informationStatus of the CUORE experiment at Gran Sasso
University and INFN Genova ICHEP 2012 MELBOURNE JULY 2012 on behalf of the CUORE collaboration Status of the CUORE experiment at Gran Sasso Double beta decay Rare nuclear decay: (A, Z) (A, Z+2) + 2e- (+2
More informationThis paper should be understood as an extended version of a talk given at the
This paper should be understood as an extended version of a talk given at the Abstract: 1 st JINA workshop at Gull Lake, 2002. Recent experimental developments at LANL (Los Alamos, NM, USA) and CERN (Geneva,
More information