Choosing the Right KLEENGUARD* Chemical Resistant Glove for the Job
|
|
- Marvin Gilmore
- 6 years ago
- Views:
Transcription
1
2 Choosing the Right KLEENGUAR* Chemical Resistant Glove for the Job This guide presents the results of standard permeation testing and degradation ratings for Kimberly-Clark s family of KLEENGUAR* Chemical Resistant Gloves. It is intended as a tool to help you assess which glove is best suited for working with specific chemicals. This guide is not designed to consider every possible factor or circumstance relative to safety in every environment. To select the appropriate glove protection, a Hazards Analysis and Risk Assessment should be performed, including identification of the chemicals and chemical hazards related to the worker s task and work environment; determination of the potential for exposure and the type of exposure that is expected (i.e. splash, saturation, spray, immersion, etc.); and determination of the consequences related to exposure. It is the responsibility of the user to assess the types of hazards and the risks associated with exposure and to make a final decision on the appropriate personal protective equipment needed for his specific circumstance. Time: Measured in minutes, this is the amount of time between the initiation of the permeation test and analytical detection of the chemical on the reverse side of the sample material. times give an indication of how long a glove, that s totally immersed in the test chemical, can provide resistance to chemical permeation. Rate: The maximum rate at which a permeating chemical passes through the fabric as measured by the analyzer. It is reported as micrograms per square centimeter of fabric per minute. Note: The combination of breakthrough time and permeation rate should be taken into consideration when making a glove selection. The goal is to provide the wearer with the least possible amount of chemical exposure for the duration of the task. Therefore, a long breakthrough time and a low permeation rate results in less chemical exposure over time compared to a shorter breakthrough time and a higher permeation rate. egradation: This is the measurement of changes in the physical properties of a glove material, after contact with a chemical. The changes may include a stiffening of the material, becoming hard or brittle; or the glove material may swell and become softer and weaker. Understanding Testing Terminology : This is a process by which a chemical can breach a surface in which no perceptible openings are present. In permeation, the chemical s molecules actually slip between the molecules of the glove material and are detected. The results of the permeation process are undetectable by the naked eye.
3 How to Utilize this Chemical Resistance Guide Three categories of data are provided for each product and corresponding chemical: 1) breakthrough time; 2) rate, and 3) egradation resistance rating. Color Code System A glove/chemical combination receives a rating if either Condition A or B is met. Condition A The permeation breakthrough time is 240 minutes or longer. The permeation rate is not specified. The degradation rating is or. OR Condition B The permeation breakthrough time is 30 minutes or longer. The permeation rate is or. The degradation rating is or. A glove/chemical combination receives RE if: the degradation rating is Not Recommended, regardless of the permeation time or rate; or if the breakthrough time is less than 30 minutes and the degradation rating is poor. glove/chemical combination not meeting either set of conditions required for or RE receives a, or cautionary rating. Criteria for Chemical Resistance Guide Time () Not Rated Minutes > 240 > < 10 Rate () egradation () (E) (G) (P) Not Recommended (NR) µg/cm 2 /min < 1 < 100 < 10,000 The results for this specific chemical suggest that the glove would provide adequate barrier for use in most applications. RE Not recommended for use. Key ; fluid has very little degrading effect. ; fluid has minor degrading effect. ; fluid has pronounced degrading effect. NR Fluid was not tested against this material or the fluid has excessive degrading effects. The results require additional consideration by a safety professional to determine suitability for use. For additional information on choosing the right chemical glove for your application, please visit our Chemical Resistance atabase at:
4 Glove Comparison Chart of KLEENGUAR* G80 Chemical Resistant Gloves KLEENGUAR* Brand Glove Chemical Resistance Guide G80 Purple Nitrile G80 Neoprene/ Latex G80 PVC G80 Purple Nitrile G80 Neoprene/ Latex G80 PVC Acetaldehyde Acetic acid Acetonitrile Aluminum Sulfate Ammonia Ammonia Nitrate (fertilizer) Ammonium Hydroxide Aniline Benzylic Alcohol Boric Acid Brake Fluid 1,3 Butadiene (gas) Bromopropionic Acid Butyl Carbitol Carbon isulfide Carbon Tetrachloride Chloracetone Chlorine (gas) Chromic Acid Citric Acid 10% Cumene Cutting Oil Cyclohexane iesel Fuel iethyl Ether imethylformamide (MF) ioctyl Phthalate Ethyl Alcohol (ethanol) Ethyl Benzene Ethylene ichloride Ethylene Glycol Ethylene Oxide (gas) Fertilizer (liquid) Formaldehyde Formic Acid Fuel Oil Furniture Polish Gasoline Herbicide (liquid) n-heptane n-hexane Hexane Hydraulic Fluid Hydrochloric Acid Hydrofluoric Acid 47% Hydrogen Peroxide Isobutylene (gas) Isopropanol 90% (IPA) Kerosene Linseed Oil Methanol Methyl Ethyl Ketone Methyl Formate Methyl Tert Butyl Ether (MTBE) Methylene Bisphenyl Isocyanate 4,4- Methylene Sulfoxide (MSO) Mineral Spirits Motor Oil Muriatic Acid (Concrete) Nitric Acid 70% Nitrobenzene Oleic Acid Oleum Perchlorethylene Phenol Phosphoric Acid Pine Oil Polyurethane Potassium Hydroxide 50% Rust Remover Sodium Hydroxide 50% Sodium Hypochlorite (bleach) Sulfuric Acid (47%) - battery Sulfuric Acid 96% Tetrachloroethylene 1,1,1 Trichloroethane Toluene Turpentine Vinyl Acetate Weed Killer Window Cleaner (ammonia based) Wood Finish Wood Preservative p-xylene See color code chart on next page
5 KLEENGUAR* G80 PURPLE NITRILE* Chemical Resistant Gloves KLEENGUAR* G80 PURPLE NITRILE* Chemical Resistant Glove Time () Rate () egredation () Overall Time () Rate () egredation () Overall Acetonitrile Ammonia Ammonium Nitrate (fertilizer) Brake Fluid 1, 3 Butadiene (gas) Carbon isulfide Carbon Tetrachloride Chlorine (gas) Cumene Cutting Oil Cyclohexane iesel Fuel imethylformamide (MF) ioctyl Phtalate Ethyl Benzene Ethylene ichloride Ethylene Glycol Ethylene Oxide (gas) Formaldehyde Fuel Oil Gasoline Herbicide n-heptane n-hexane Hydraulic Fluid Hydrogen Peroxide E E 9 26 G G E P G G E G >480 N G Isobutylene (gas) Isopropanol 90% (IPA) Kerosene Methanol Methyl Ethyl Ketone Methyl Sulfoxide (MSO) Methyl Tert Butyl Ether Mineral Spirits Motor Oil Muriatic Acid (concrete etch) Nitrobenzene Perchlorethylene Pine Oil Potassium Hydroxide 50% Rust Remover Sodium Hypochlorite (bleach) Tetrachloroethylene Toluene 1,1,1 Trichloroethane Turpentine Vinyl Acetate Weed Killer Window Cleaner (ammonia based) Wood Finish Wood Preservative p-xylene G 5 P * E E P G G 11 High P 34 High G G G N = Not etected * = Immediate RE TAN >240 >30 <100 NR <30 P No Results Reported Criteria for Chemical Resistance Guide Time () Not Rated Rate () Minutes > 240 > < 10 µg/cm 2 /min < 1 < 100 < 10,000 egradation () (E) (G) (P) Not Recommended (NR) Other Condition
6 KLEENGUAR* G80 Neoprene / Latex Chemical Resistant Gloves KLEENGUAR* G80 Neoprene/Latex Chemical Resistant Glove Time () Rate () egredation () Overall Time () Rate () egredation () Overall Acetaldehyde Acetic Acid Aluminum Sulfate Ammonium Hydroxide Aniline Benzylic Alcohol Boric Acid Chloracetone Citric Acid 10% Cutting Oil iethyl Ether Ethyl Alcohol (ethanol) Ethylene Glycol Formaldehyde Furniture Polish Herbicide Hydrochloric Acid Hydrofluoric Acid 47% Hydrogen Peroxide Isopropanol 90% (IPA) Linseed Oil E E >480 N E E >480 N 2 High E E > E >480 N E >480 N G E G Liquid Fertilizer Methyl Ethyl Ketone Methyl Formate Mineral Spirits Muriatic Acid (Concrete) Nitric Acid 70% Oleic Acid Phenol Phosphoric Acid Polyurethane Potassium Hydroxide 50% Rust Remover Sodium Hydroxide 50% Sodium Hypochlorite (bleach) Sulfuric acid 47% (battery acid) Sulfuric Acid 96% Turpentine Vinyl Acetate Windex Wood Finish P G G >480 N G E >480 N G G E NR 32 High NR 4 High NR G G N = Not etected NR = Not Recommended >240 >30 <100 RE NR <30 P TAN No Results Reported Other Condition
7 KLEENGUAR* G80 PVC Chemical Resistant Gloves KLEENGUAR* G80 PVC Chemical Resistant Glove Aniline Bromopropionic Butyl Carbitol Chromic Acid Ethyl Alcohol Formic Acid Methylene Bisphenyl isocyanate 4,4- Nitric Acid Oleum Phenol Sulfuric Acid P-Xylene N = Not etected NR = Not Recommended Time () Rate () egredation () F G E >480 N G G F F G G NR Overall Ongoing chemical testing for the KLEENGUAR* G80 Chemical Resistant Gloves will occur and data tables will be updated accordingly. >240 >30 <100 RE NR <30 P TAN No Results Reported Other Condition Caution: This product contains Natural Rubber Latex which may cause allergic reactions. Kimberly-Clark warrants that its products comply with K-C s standard specifications as of the delivery date to K-C s authorized distributors/direct purchasers. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXESS OR IMPLIE, INCLUING ANY WARRANTY OF MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. K-C is not liable for any kind of special, incidental, or consequential damages. K-C s liability for breach of contract, tort, or other cause of action shall not exceed the product purchase price. Purchasers and users are deemed to have accepted the above warranty and limitation of liability, and cannot change the terms by verbal agreement or by any writing not signed by K-C. Warnings: Improper use or failure to heed warnings may result in serious injury or death. Gloves should be replaced immediately if ripped, torn, abraded or punctured. Gloves are not flame resistant. Keep away from sparks, flames and sources of heat and ignition. Melting fabric can cause severe burns. It is the responsibility of the user to assess the types of hazards and the risks associated with exposure and then decide on the appropriate personal protective equipment needed for each circumstance. The information provided within this literature refers to the performance of the film only, in the laboratory under controlled conditions. Kimberly-Clark makes no representation that its products will provide complete protection from exposure to contaminants. /* Trademarks of Kimberly-Clark Worldwide, Inc. Marques deposees de Kimberly-Clark Worldwide, Inc. The COLOR PURPLE is a Registered Trademark of KCWW KCWW. K00484 K
Safe Installation and Use of the NanoRam Immersion Probe
Safe Installation and Use of the NanoRam Immersion Probe Description: NanoRam Immersion Probe - 12 inch length; Immersion Probe Disposable Protective Sleeve Model Number: NR2-IMP; NR2-IMPS Part Number:
More informationGlove Selection Chart
Glove Selection Chart The following guide is a general guide for glove selection in relation to chemicals handled. The information presented here is believed to be accurate; however, we cannot guarantee
More information500 SERIES CHEMICAL RESISTANCE GUIDE
500 SERIES CHEMICAL RESISTANCE GUIDE INTRODUCTION The Stonchem 500 Series Chemical Resistance Guide is designed to aid in the proper selection of material for every job application. Exposure to over 250
More informationTAMMSFLEX SL / TAMMSFLEX NS
Acetic Acid, 10% 1 1 2 4 Acetic Acid, 50% 1 1 2 4 Acetic Acid, Glacial 1 4 - - Acetone 1 1 1 4 Acrylonitrile 2 4 - - Aluminum Sulfate(aq), 50% 1 1 1 1 Ammonium Chloride(aq), 50% 1 1 1 1 Ammonium Hydroxide(aq),
More informationGloves: choice and use
Gloves: choice and use Adopted April 15 th, 2003 Comité sectoriel de sécurité du Département de chimie Université Laval Wearing gloves: why? Gloves are worn for protection. However, gloves do not always
More informationSizes 48" x 96" (1.22m x 2.44m) Custom sheet sizes available upon request
Applications Decorative paneling Partitions Water features Signage Furniture Displays and more... Attributes Excellent UV properties High impact resistance - 17x greater than glass and 4x greater than
More informationAppendix 5: table of chemical compatibility for tubing
Appendix 5: table of chemical compatibility for tubing KEY 1 Excellent 2 Good 3 Fair 4 Not recommended - no data Silicone PharMed Iso-Versinic PVC Acetaldehyde 3 4 4 2 Acetamide, 67% in w 1 2 4 4 Acetate
More informationPRODUCT DATA SHEET PDS A88_E
Plugs Suitable for A B C D Ref. Quantity Box/Bag (mm) (mm) (mm) (mm) TCP5 M12R + Pg7R M12R 4,5 8,5 10,8 4,5 3.000/100 TCP10 Pg9R Pg9R 6 12 12 4,5 2.000/100 TCP12 M12 + Pg7 M12 + Pg7 M16R + Pg11R M16R +
More informationColor Availability Clear Standard colors stocked (thin gauge only) Custom colors available by special order.
Applications Aquariums Displays Fountains Projection screens Furniture Optical lenses Port hole windows Sight glass Scientific applications Point of purchase Vacuum chambers Bio-safety chambers and more...
More informationChemical Polyurethane Polyethelyne PVC Nylon 11 Kynar
ACETIC ACID, GLACIAL 4 2 4-1 ACETIC ACID, 30% 4 1 4 2 1 ACETONE 4 2 4 1 4 ACETYLENE 1 4 1 1 1 ALKAZENE 4 - - - - ALUMINUM CHLORIDE (aq) 3 2 1-1 ALUMINUM NITRATE (aq) 3-2 - 1 AMMONIA ANGYDROUS 4 2 1-4 AMMONIA
More informationChemical Compatibility Guide Issue One
CNAF X Chemical Compatibility Guide Issue One Chemical Compatibility Guide Chieftain X, Centurion X, and Sentinel X compressed non asbestos fibre sheet gasket materials The following information is issued
More informationPRODUCT DATA SHEET PDS A112_E. Metric thread M 1.5 pitch CEI EN CEI EN 50262
reduced cable entry Metric thread M 1.5 pitch CEI EN 60423 CEI EN 50262 Ref. P Fixing A B C L Light Hole min-max Spanner min-max Quantity Grey (mm) (mm) (mm) (mm) (mm) 1910S.M16N M16x1,5 16,5 4-7,5 19
More information8 Materials, Corrosion Resistance Tables
8 Materials, Corrosion Resistance Tables Included among the criteria for meter selection are the materials to be utilized. Of primary interest are those materials which come in contact with the measuring
More informationHSW NORM-JECT SYRINGES CHEMICAL RESISTANCE CHART
A Beer + + Acetic acid (10-60%) + O Benzaldehyde + O Acetic acid (1-10%) + + Benzene O - Acetic acid (80-100%) + O Benzene sulfonic acid + + Acetic anhydride + + Benzoic acid + Acetone + + Bismuth carbonate
More informationSwell Sheet Chemical Resistance Guide
Swell Sheet Chemical Resistance Guide MULTI-SWELL 3760 Rev. 3/2018 LEAK-GARD 3750 KEY: A - Ideal for low pressure applications B - Fair, Depends on conditions; please contact Applications Engineering C
More informationBEST PRACTICE GUIDELINES
In collaboration with : iw BEST PRACTICE GUIDELINES Safe use of gloves for the handling of solvents Safe use of gloves for the handling of solvents September 2018 Foreword The European Solvents Industry
More informationCHEMICAL RESISTANCE LIST
1,1,1 Trichloroethane C 2 H 3 CI 3 100 2-Butanoxim C 4 H 9 NO 100 COOH 1 60 COOH 5 COOH 5 60 COOH 10 COOH COOH 20 Acetone CH 3 COCH 3 100 Alaun KAl( ) 2 Aluminium Chloride AlCl 3 Aluminium Chloride AlCl
More informationTube O Reactor. (Micro: Cat. # K, K, K) (Medi: Cat. # K, K, K)
453PR G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Tube O Reactor (Micro: Cat. # 786 024 4K, 786 024 8K, 786 024 15K) (Medi: Cat. # 786
More informationChemical Resistance Guide for Flowchem EPN
Chemical Resistance Guide for Flowchem EPN This guide is designed to aid in the proper selection of material for every job application. Exposure to over 250 chemicals are rated for specific temperature
More informationSwell Sheet Chemical Resistance Guide
Swell Sheet Chemical Resistance Guide MULTI-SWELL 3760 Rev. 6/2016 LEAK-GARD 3750 KEY: A - Ideal for low pressure applications B - Fair, Depends on conditions; please contact Applications Engineering C
More informationEN ISO 374 Summary of changes & FAQ s Sept 2017
EN ISO 374 Summary of changes & FAQ s Sept 2017 EN ISO 3 74 www.bioclean.com EN ISO 374 Summary of changes & FAQ Understanding the changes and frequently asked questions about the new EN ISO 374 standard
More informationPRODUCT DATA SHEET PDS A4_E. Metric thread M 1.5 pitch CEI EN CEI EN 50262
Ref. Light Grey P Fixing A B C L Hole min-max Spanner min-max (mm) (mm) (mm) (mm) (mm) Quantity 1900.M12 M12X1,5 12,5 3,5-7 15 8 18-22 100 1900.M16 M16X1,5 16,5 5-10 19 8 22-27 100 1900.M20 M20X1,5 20,5
More informationRevised Permeation Values for DuPont Tychem SL
Revised Permeation Values for DuPont Tychem SL Chemical Name Revised Permeation Values for DuPont Tychem SL (as of January, 2011) ACETIC ACID 64-19-7 >480 >480 ACETIC ANHYDRIDE 108-24-7 48 48 ACETONE 67-64-1
More informationChemical Storage According to Compatibility
Chemical Storage According to Compatibility To lessen risk of exposure to hazardous chemicals, all chemicals should be separated and stored according to hazard category and compatibility. *Storage Groups
More informationMSE Seminar Laboratory Safety Skills
MSE Seminar Laboratory Safety Skills MSEGSA Safety Committee Cem Akatay John Koppes Kate Hess Pylin Sarobol Topics Personal Protective Equipment Proper glove selection and use When to use goggles and aprons
More informationSOLUZIONI PER L ENERGIA TERMICA THERMAL ENERGY SOLUTIONS
Table on chemical resistance of rubber materials Class 1 little or no effect Class 2 minor effect Class 3 moderate effect Class 4 severe effect Chemical Conc. Temp. EPDM NBR VITON % C Acetic acid 10 50
More informationHalar ECTFE chemical resistance chart
Technical Information Halar ECTFE chemical resistance chart Introduction Halar ECTFE is one of the most chemically resistant polymers available today. This chemical resistance is due to the chemically
More informationPeek Chemical Resistance
Peek Chemical Resistance R = Resistant LR = Limited Resistance NR = Not Recommended ND = No Data Chemical Resistance 20 o C 60 o C 100 o C Acetaldehyde NR NR R Acetic acid (10%) R R R Acetic acid (glac./anh.)
More informationN6,6 Posidyne Membranes
Rev. Date: 20-Jun-2010 Ultipor Nylon 6,6 and N6,6 Posidyne Membrane Description Pall provides a complete range of Nylon 6,6 membranes for fluid filtration in the pharmaceutical, biotechnology, electronics,
More informationFluid Compatibility Table
Acetaldehyde C A A A B D C A A Acetate Solvents A B A A D D A A Acetic Acid, crude C B A A D D A A Acetic Acid, pure D B A A D D A A Acetic Acid, 10% C B A A B D D A A Acetic Acid, 80% C B A A C D D A
More informationMicro Float-A-Lyzer READY-TO-USE MICRODIALYSIS DEVICES. Product Information & Operating Instructions
Spectra/Por Micro Float-A-yzer EADY-TO-USE MICODIAYSIS DEVICES Product Information & Operating Instructions Table of Contents Introduction....................................1 Applications...................................2
More informationChemical Resistance Properties of Anko Tubing
Chemical Resistance Properties of Anko Tubing E = Excellent G = Good F = Fair X = Not Recommended U = Untested Environment, % Conc.* w = Water alc = Alcohol * If concentration is not indicated, assume
More informationSpillSolv. Chemical Spill Treatment Kits
SpillSolv Chemical Spill Treatment Kits Features & Benefits Compe SpillSolv Chemical Spill Treatment Kits EMD Chemicals offers the next generation in spill cleanup technology. SpillSolv Chemical Treatment
More informationNaOH CH 3 CO 2 H C 2 H 5 OH. NaCl H 2 SO 4. Technical. Technical. Chemical Resistance Terms of Sale
CH 3 CO 2 H NaOH NaCl C 2 H 5 OH H 2 SO 4 Technical Terms of Sale Technical Acetaldehyde C C A C1 A1 D A A Acetamide A A A D A1 C A A Acetate Solvent A A A B1 A A Acetic Acid: 80% A D D B1 A C D B 20%
More informationMedia Compatibility Guide PVC Valves
73 F (23 C) Valves WARNING This chart indicates the suitability of various elastomers and plastics for use with fluids to be conveyed. It should be used only as a guide for the selection of valve materials.
More informationSpectra/Por. Float-A-Lyzer READY-TO-USE DIALYSIS DEVICES. Product Information & Operating Instructions
Spectra/Por Float-A-yzer G2 EADY-TO-USE DIAYSIS DEVICES Product Information & Operating Instructions Table of Contents Introduction....................................1 Applications...................................2
More informationSafety Manual > Incompatible Chemicals Partial Listing
Safety Manual > Incompatible Chemicals Partial Listing C. Incompatible Chemicals Partial Listing Chemical Incompatible Chemicals Acetic acid Chromic acid, nitric acid, permanganates, and peroxides Acetic
More informationHAZARDOUS MATERIALS SURVEY. Note: List ALL virgin stock materials in current and projected inventories LAB NAME: PI: ADDRESS:
HAZARDOUS MATERIALS SURVEY Note: List ALL virgin stock materials in current and projected inventories LAB NAME: PI: ADDRESS: Please read each definition of the following Hazardous Materials carefully and
More informationFUNDERMAX GMBH TEST REPORT
FUNDERMAX GMBH TEST REPORT SCOPE OF WORK SEFA 3 2010, 2.1 Analysis of Max Compact Interior Plus White and Black Plaques REPORT NUMBER 103600635GRR 001a ISSUE DATE 25 September 2018 PAGES 22 DOCUMENT CONTROL
More informationMagnetic Flowmeter Material Selection Guide
Magnetic Flowmeter Material Selection Guide www.sparlinginstruments.com Introduction The purpose of this guide is to provide a general resource for the selection of materials for the magnetic flowmeter.
More informationTest Report For: FunderMax GmbH. MAX Resistance 2. SEFA , 2.1 Chemical/Stain Resistances
4700 Broadmoor SE, Suite 200 Kentwood, MI 49512 Telephone: 616-656-7401 Facsimile: 616-656-2022 www.intertek-etlsemko.com P.O. No.: MP Page 1 of 9 Test Report For: FunderMax GmbH MAX Resistance 2 SEFA
More informationChemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder
Contact Us: www.pall.com/contact Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder Introduction
More informationChemical Resistance. Suitable Suitability depends on operating conditions Unsuitable. Topchem 2000/2003. Milam PSS / Mica. Hygrade LS / PTFE.
Chemical Resistance A Klinger gasket materials can be selected from the following table. The following information should be used as a guide only. Please contact our Technical Services Department if in
More informationChemical Resistance of PVC Products
The mechanism of chemical attack on thermoplastics in general, and PVC sheets in particular, differs significantly from the mechanism of corrosion of metals. Corrosion of metals results in a gradual loss
More informationMolded/Machined Both Both Machined Machined Both Dielectric Strength V/mil D ,000
Material Properties Properties Units ASTM Test Method ABS Acetal CPVC G10-FR4 Halar (ECTFE) Molded/Machined Both Both Machined Machined Both Dielectric Strength V/mil D-149 812.8 500 1250 400 2,000 Elongation
More informationCOPPER SHEATHED CABLE
COPPER SHEATHED CABLE CORROSION RESISTANCE OVERVIEW nvent PYROTENAX sheathed cables are noted for their general resistance to chemical corrosion as compared to most other metals. However, as with all metals,
More informationDuPont Personal Protection Product Catalog
Page 1 of 7 Customer Service: 1-800-931-3456 or personalprotection@usa.dupont.com Tychem QC Style: QC526B Print Page Garment Description and Features Fully encapsulated suit, standard face shield (made
More informationMaterials of Construction and Chemical Compatibility for Sensing and Control Products
ADVANCED MATERIALS HANDLING TECHNICAL NOTE Materials of Construction and Compatibility for Sensing and Control Products INTRODUCTION Entegris Sensing and Control products are designed for use in highly
More informationCHEMICAL RESISTANCE TABLE
Page 1 of 14 The data given in the extensive Table below is the current best state of information known to Nylact. Polymer compatibility with solvents other than those in this chart may arise: the General
More informationThe best material for original Eppendorf Tubes and Plates: Properties and chemical resistance of polypropylene
APPLICATION NOTE No. 056 I June 2013 The best material for original Eppendorf Tubes and Plates: Properties and chemical resistance of polypropylene Natascha Weiß, Susanne Pruszkowski, Eppendorf AG, Hamburg,
More informationProper Storage of Chemicals in Laboratories
Proper Storage of Chemicals in Laboratories Dr. Ideisan I. Abu-Abdoun Department of Chemistry UOS abuabdoun@sharjah.ac.ae UOS 28 - Feb. 2013 Contents Introduction Requirements Storage Facilities and Practices
More informationPrincipal Investigator: Department: Laboratory room #s: Updated/revised: Chemical Name Amount Physical state Location Hazard Class
Chemical Inventory Principal Investigator: Department: Laboratory room #s: Updated/revised: Chemical Name Amount Physical state Location Hazard Class 1 SUGGESTED SHELF STORAGE PATTERN - ORGANIC Organic
More informationEppendorf UVette. Instructions for use
Instructions for use Instructions Eppendorf see Fig. Tab. p. p. UVette for use Copyright 2014 Eppendorf AG, Hamburg, Germany. All rights reserved, including graphics and images. No part of this publication
More informationSolshield Hydrocarbon Gas Membrane Chemical Resistance Table
Symbol Key: + Resistant (polymer swelling property < 3 % or polymer mass decrease < 0,5 %, polymer extensibility is not substantially changed) / Limited resistance (polymer swelling property in the range
More informationTPE CHEMICAL RESISTANCE
PE CHEMICAL ESISANCE CONENS INODUCION OVEVIEW OF CHEMICAL ESISANCE CHEMICAL ESISANCE OF SEBS BASED PE COMPOUNDS CHEMICAL ESISANCE OF SEBS AW MAEIALS CONACS INODUCION Dryflex and Mediprene PE compounds
More informationA freely accessible HNS data base
Improving Member States preparedness to face an HNS pollution of the Marine System (HNS-MS) A freely accessible HNS data base The HNS data base in a nutshell 120 HNS, described by 90+ data covering 6 main
More informationGlobally Harmonized System of Classification and Labeling of Chemicals (GHS) LC-1033p Rev. 06/16
Globally Harmonized System of Classification and Labeling of Chemicals (GHS) Rev. 06/16 Agenda Introduction to Globally Harmonized System of Classifying and Labeling Chemicals Hazard & Precautionary Statements
More informationChemMAX 3. for use in Nuclear, Biological and Chemical Environments
ChemMAX 3 for use in Nuclear, Biological and Chemical Environments Introduction N.B.C suits are used in various situations where protection from Nuclear, Biological and / or Chemical hazards may be required.
More informationCHEMICAL RESISTANCE DATA FOR POLYETHYLENES
CHEMICAL RESISTANCE DATA FOR POLYETHYLENES [ R = Resistant LR= Low Resistance NR= Not Resistant] 23 o C 60 o C 23 o C 60 o C Acetaldehyde(100%) LR NR LR NR Acetic acid (10%) R R R R Acetic acid (50%) R
More informationChemical Safety. Peter Yeung D.G. Manager. Safety Office The University of Hong Kong
Chemical Safety Peter Yeung D.G. Manager Safety Office The University of Hong Kong Lesson Learned 1. Laboratory fire 2. Chemical spill 3. Incompatibles in waste disposal Lab. Fire Sodium/Solvent Chemical
More informationLiquid is assumed to be at saturated concentration in aqueous solution unless stated otherwise.
Chemical Resistance Data Note: The following tables are intended to serve only as your reference of materials, and are not intended to guarantee our products. When using the data in the tables, please
More informationstance et Helper Eppendorf Pipet Helper Chemical Resistance
stance et Helper Resistance N) Chemical Resistance Copyright 2017 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication may be reproduced without the prior
More information/ / /
www.growland.net / www.growland-hydroponics.com https://www.growland.fr / https://www.growland.co.uk https://www.growland.es / https://www.growland.at https://www.growland.nl / https://www.growland.it
More informationZirconium in Organic Applications
Zirconium in Organic Applications INTRODUCTION Laboratory studies and case histories have established zirconium as the most corrosion resistant material of construction in many production methods involving
More informationAPPENDIX C CHEMICALS USED IN CLANDESTINE DRUG LABS
APPENDIX C CHEMICALS USED IN CLANDESTINE DRUG LABS You must exercise extreme caution when ope at the scene of an illegal drug lab. Do not walk into, touch, or move chemicals or spilled material. Avoid
More informationCombustible Gas Catalytic Bead (0-100 %LEL) Part No FM Performance Certified 1,4 FM Performance Certified 1
Sensor Data Sheet Document No. 365-2211-31 (Rev D) Combustible Gas Catalytic Bead (0-100 %LEL) Part No. 823-0211-31 FM Performance Certified 1,4 FM Performance Certified 1 Minimum Indicated Concentration...
More informationCHEMICAL GLOVE SELECTION PROCESS
CHEMICAL GLOVE SELECTION PROCESS INTRODUCTION WITH MORE THAN 60 MILLION REGISTERED CHEMICALS, FINDING THE RIGHT CHEMICAL PROTECTIVE GLOVE IS NOT AN EASY TASK. Selection of chemical protective gloves is
More informationChemical Segregation and Storage Guide
Chemical Segregation and Storage Guide This resource developed by LabCentral for the Pagliuca Harvard Life Lab Revision 1, Effective Dec 13, 2016 Table of Contents 1.0 PURPOSE AND SCOPE...3 2.0 CLASSES
More informationCHEMICAL RESISTANCE CHART
CHEMICAL RESISTANCE CHART The information in this chart has been supplied to Biotix by various reputable raw material manufacturers, and is to be used only as a guide in selecting products for appropriate
More informationCHEMICAL RESISTANCE LIST
CHEMICAL RESISTANCE LIST The information provided is designed to be used as a guide and all information must be checked on a project basis. Data based upon room temperatures. Elevated temperatures will
More informationLABORATORY SAFETY PLAN APPENDIX
LABORATORY SAFETY PLAN APPENDIX APPENDIX 1 REQUIRED CEE LAB ACCESS FORMS CEE Laboratory User Form As a laboratory user in the Department of Civil and Environmental Engineering at Northeastern University,
More informationPREVENTING HAZARDOUS WASTE FINES
University of Medicine and Dentistry of New Jersey EOHSS FACTSHEET PREVENTING HAZARDOUS WASTE FINES In the last few years institutions such as MIT, University of New Hampshire, Yale, Stanford, and Boston
More informationMatte (MA): A fine beaded texture with a slight sheen
ArboChem Arborite s chemical and stain-resistant laminate ArboChem is a special category of decorative panels engineered to resist a variety of acids, solvents, general reagents and cleaning agents. Design
More informationWESTERN CONNECTICUT STATE UNIVERSITY CHEMICAL STORAGE AND COMPATIBILITY GUIDELINES PROCEDURE S-118
WESTERN CONNECTICUT STATE UNIVERSITY CHEMICAL STORAGE AND COMPATIBILITY GUIDELINES PROCEDURE S-118 Issued 6/4/02 Please direct any questions or comments about the applicability of this document to Luigi
More informationChemical Storage Guidelines
Storage Guidelines Do not store excess chemical containers on the benchtops, designate a storage location and return containers to that location after each use. Do not store chemicals in the fume hood.
More informationPlugs, mobile sockets, panel mounting sockets, surface mounting sockets, P17 Tempra Pro IP44 and low voltage 66/67
Pro and low voltage 66/67 ONTENTS Page 1. General characteristics...1 2. Use...1 3. Range/Equivalence table...1 4. Dimensions..............................3 5. Technical characteristics...6 6. Installation....7
More informationgerflor.com.au Stain chemicals
gerflor.com.au Stain resistance: list of chemicals PRODUCTS/ TIME MIPOLAM TARALAY TARALAY / WALL CONCENTRATED ACID Acetic acid - CH 3 -COOH 14 0 0 0 0-1d 0-1d 0-1d 1d 1d 2d 0 0 0-1d Hydrochloric acid -
More informationDRUM PUMP CHEMICAL RESISTANCE GUIDE & APPLICATION WORKSHEET
DRUM PUMP RESISTANCE GUIDE & APPLICATION WORKSHEET CRG 012516 1 DRUM PUMP RESISTANCE GUIDE & APPLICATION WORKSHEET The information in this Chemical Resistance Guide is to be used only as a general guide
More informationPRODUCT DATA SHEET PDS A5_E
OMRESSION AE GANDS OYAMIDE A6.6 MAXIOK 1900 SERIES G THREAD ight Grey standard g thread DIN 40 430 1900.07 g 7 12,7 3,5-7 15 8 18-22 100 1900.09 g 9 15,5 5-8 19 8 22-26 100 1900.11 g11 18,8 5-10 22 8 23-28
More informationZeta Plus LP Series. Lenntech. Applications. Features and Benefi ts. Lenticular Depth Filter Cartridges
Lenntech info@lenntech.com Tel. +3-52-6-9 www.lenntech.com Fax. +3-52-66-289 Zeta Plus LP Zeta Plus LP filter media is a depth filter composed of inorganic filter aid cationic resin and cellulose and is
More informationPolyethylene Chemical Resistance. ARM Fall Conference 2015, Denver CO. Carmine D Agostino, Technical Service and Application Development
Polyethylene Chemical Resistance Workshop ARM Fall Conference 2015, Denver CO Carmine D Agostino, Technical Service and Application Development 1 Contents Introduction Definition Chemical Effects on Polyethylene
More informationstance 4 Repeater M4 Register your instrument! Multipette M4 Repeater M4 Chemical Resistance
stance 4 Repeater M4 Resistance N) Register your instrument! www.eppendorf.com/myeppendorf Chemical Resistance Copyright 2013 Eppendorf AG, Hamburg. No part of this publication may be reproduced without
More informationMasterSeal M 452. Water based epoxy bituminous chemically resistant waterproofing membrane.
DEFINITION Water based two components epoxy bituminous water vapor permeable and chemically resistant waterproofing membrane. CONSUMPTION System Build 1: thickness 350 µm. Technique Product kg/m 2 Primer
More informationGL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI
syringe filters promises reproducible results from the filtration of organic and aqueous solutions in HPLC. Trace amount of samples containing impurities or contaminants can be easily removed, resulting
More informationQUICK SELECTION GUIDE TO CHEMICAL PROTECTIVE CLOTHING
QUICK SELECTION GUIDE TO CHEMICAL PROTECTIVE CLOTHING QUICK SELECTION GUIDE TO CHEMICAL PROTECTIVE CLOTHING Sixth Edition Krister Forsberg, Lidingo, Stockholm, Sweden Ann Van den Borre, Liedekerke, Brussels,
More informationPROCESS TECHNOLOGY- ORGANIC II. 51. Gas phase dehydrogenation of ethyl-benzene to styrene occurs over catalyst based on
PROCESS TECHNOLOGY- ORGANIC II 51. Gas phase dehydrogenation of ethyl-benzene to styrene occurs over catalyst based on (a) iron oxide, (b) silica alumina, (c) titanium dioxide, (d) sodium silicate, 52.
More informationBGSU s Guide to Chemical Storage
BGSU s Guide to Chemical Storage Environmental Health & Safety 372-2171 Chemical Storage Guidlines General Guidelines Store dry chemicals on shelves. Store flammables together. Use approved flammable storage
More informationCORROSION RESISTANCE GUIDE INDUSTRIAL PRODUCTS
CORROSION RESISTANCE GUIDE INDUSTRIAL PRODUCTS 2 The cover photo shows severe, short-term corrosive effects of 37% sulfuric acid on various materials. All bar samples originally measured 6 long x 1/4 thick
More informationcatalogue of thermoplastic Gears
catalogue of thermoplastic Gears Why thermoplastic gears. five reasons to switch to thermoplastic transmission gear. first lighter second CHeaPer third noiseless fourth self-lubricating fifth PerforManCe
More informationDispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during
The New Generation! Dispensette S Bottle-top Dispenser F I R S T C L A S S B R A N D Innovative ideas with trusted technology the new bottle-top dispenser. n New discharge tube with or without recirculation
More informationDispensette. Dispensette the right bottle-top dispenser for your application.
Dispensette the right bottle-top dispenser for your application. Dispensette F I R S T C L A S S B R A N D The original Dispensette with its broad range of application has proven reliable for accurate
More informationFR CLOTHIN G FOR L ABORATORIES
FR CLOTHIN G FOR L ABORATORIES Personal protective equipment (PPE) for laboratory workers, including safety glasses or goggles, gloves, breathing masks, and lab coats, play an important role in lab safety.
More informationBM Polyco Test Laboratories. SuperGlove Range. EN374-3 Determination of Resistance to Permeation by Chemicals
BM Polyco Test Laboratories The state-of-the-art Technical Department laboratories at BM Polyco are equipped to carry out a range of tests on protective gloves. The chemical and physical test laboratories
More informationPermadri Chemical Resistance Chart
1 Acetic acid CH 3 COOH >20% w/w Unsuitable Suitable Acetic acid 2-20% w/w Limited Suitable Acetic acid
More informationQuick Selection Guide to Chemical Protective Clothing Fourth Edition A JOHN WILEY & SONS PUBLICATION
Quick Selection Guide to Chemical Protective Clothing Fourth Edition Krister Forsberg Lidingo, Sweden S.Z. Mansdorf Paris, France A JOHN WILEY & SONS PUBLICATION Quick Selection Guide to Chemical Protective
More informationPage No.: The Department of Environmental Health and Safety is responsible for;
1 Introduction The have been developed in order to minimize the risk of accidental chemical reactions and exposure resulting from the improper storage of hazardous chemicals. The chemical storage procedures
More informationCORROSION RESISTANCE GUIDE INDUSTRIAL PRODUCTS
CORROSION RESISTANCE GUIDE INDUSTRIAL PRODUCTS The cover photo shows severe, short-term corrosive effects of 37% sulfuric acid on various materials. All bar samples originally measured 6 long x 1/4 thick
More informationZeta Plus HT Series. Lenntech. Applications. Features and Benefi ts. Lenticular Depth Filter Cartridges
Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Zeta Plus Series Zeta Plus Series is a charge-modifi ed depth fi lter constructed with high-tensile strength media
More informationBELZONA PRODUCT DATA G504 CHEMICAL RESISTANCE OF BELZONA 5892
Alcohols, Aldehydes and Ketones Organic Acids Inorganic Acids BELZONA RODUCT DATA 504 CHEICAL RESISTANCE OF BELZONA 5892 10% * - Hydrochloric acid HCl 5% * - (647-01-0) 1% * - hosphoric acid (orthophosphoric
More informationAll-round protection is in your hands
All-round protection is in your hands Nitrile Glove range. Superior protection for Scientists and their Science. It all adds up... to Exceptional Laboratories Together we create Exceptional Laboratories
More information