SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

Similar documents
Light yield non-proportionality and intrinsic energy resolution of doped CsI scintillators

OPPORTUNITY TO JOIN IEEE AND NPSS

Light yield non-proportionality and energy resolution of Lu 1.95 Y 0.05 SiO 5 :Ce and Lu 2 SiO 5 :Ce scintillation crystals

Non-proportionality of organic scintillators and BGO

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Compton suppression spectrometry

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

Energy Resolution of Scintillation Detectors New Observations

New Scintillators for the Border Monitoring Equipment

Scintillation Detector

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data

SCINTILLATION DETECTORS AND PM TUBES

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Evaluation of the Nonlinear Response Function and Efficiency of a Scintillation Detector Using Monte Carlo and Analytical Methods

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

DEVELOPMENT OF ADVANCED NEUTRON INDUCED PROMPT GAMMA- RAY ANALYSIS SYSTEM FOR SURVEY OF ANTI-PERSONNEL MINES

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

ORTEC AN34 Experiment 10 Compton Scattering

1 of :32

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Detection and measurement of gamma-radiation by gammaspectroscopy

Figure 1. Decay Scheme for 60Co

Mass of the electron m 0

Chapter 4 Scintillation Detectors

Unit 2. Instrumentation. Experts Teaching from Practical Experience

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Radiation Detection and Measurement

EEE4106Z Radiation Interactions & Detection

Ultra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

Quality Assurance. Purity control. Polycrystalline Ingots

III. Energy Deposition in the Detector and Spectrum Formation

COMPTON SCATTERING OF GAMMA RAYS

II. 5. Study for NaI(Tl) and Scintillation Fiber with 80 MeV Proton Beam Toward ESPRI Experiment at NIRS-HIMAC, RIKEN-RIBF

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Warsaw University of Technology, Faculty of Physics. Laboratory of Nuclear Physics & Technology. Compton effect

Development of a Hard X-Ray Polarimeter for Solar Flares and Gamma-Ray Bursts

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

arxiv: v2 [physics.ed-ph] 23 Jan 2018

arxiv:physics/ v1 3 Aug 2006

DETECTORS. I. Charged Particle Detectors

Scintillation Detectors

Deposited on: 20 December 2010

M.J. CIESLAK, K.A.A. GAMAGE Department of Engineering, Lancaster University Lancaster, LA1 4YW United Kingdom ABSTRACT

THE COMPTON EFFECT Last Revised: January 5, 2007

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE

Characterization of the Lanthanum Chloride Scintillation Detector

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

1842 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 5, OCTOBER M. Marisaldi, C. Labanti, H. Soltau, C. Fiorini, A. Longoni, and F.

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

A NEW GENERATION OF GAMMA-RAY TELESCOPE

Fast detectors for Mössbauer spectroscopy )

Design and production of Scintillation Detectors

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

Radiation (Particle) Detection and Measurement

Non-proportional scintillation response of NaI:Tl to low energy X-ray photons and electrons

Gamma ray coincidence and angular correlation

NUCL 3000/5030 Laboratory 2 Fall 2013

Contents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung

Analysis of γ spectrum

Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET

arxiv:hep-ex/ May 2000

High Purity Germanium Detector Calibration at ISOLDE

Researchers at the University of Missouri-Columbia have designed a triple crystal

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

Radiation Signals and Signatures in a Detector (Gamma spectroscopy) Sangkyu Lee

Gamma and X-Ray Detection

DETERMINING FUNDAMENTAL PARAMETERS OF A SINGLE-PHOTOTUBE LIQUID SCINTILLATION COUNTER

arxiv: v1 [physics.ins-det] 29 Jun 2011

Characterizing New Multi-Channel Peak Sensing ADC-Mesytec MADC-32

05 - Scintillation detectors

Design of a Lanthanum Bromide Detector for TOF PET

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

Investigation of Ce-doped Gd2Si2O7 as a scintillator. Author(s) Kurashige, Kazuhisa; Ishibashi, Hiroyuki; Furusaka, Instructions for use

Gamma Spectroscopy. References: Objectives:

Large volume LaBr 3 :Ce detectors and HECTOR +

PHYS 3446 Lecture #12

Radiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors

Radiation Dose, Biology & Risk

(10%) (c) What other peaks can appear in the pulse-height spectrum if the detector were not small? Give a sketch and explain briefly.

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

1420 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 57, NO. 3, JUNE /$ IEEE

CHAPTER-II Experimental Techniques and Data Analysis (Positron annihilation spectroscopy)

DELAYED COINCIDENCE METHOD FOR PICOSECOND LIFETIME MEASUREMENTS

Characterization and Monte Carlo simulations for a CLYC detector

INORGANIC crystal scintillators are widely used in high

2010 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Transcription:

88 The 1 st NPRU Academic Conference SCI-O11 Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator P. Limkitjaroenporn and W.Chewpraditkul Radiation Physics Laboratory, Department of Physics, Faculty of Science King Mongkut s University of Technology Thonburi, Bangkok 114, Thailand Abstract The scintillation response of a plastic scintillator (NE12) has been characterized using Compton coincidence technique. The coincidence technique allowed detection of nearly monoenergetic internal electrons resulting from the scattering of incident 662 kev gamma rays within a primary NE12 detector. Scattered gamma rays were detected using a secondary NaI(Tl) detector in a coincidence mode. The electron response nonproportionality of NE12 plastic scintillator was measured using this technique for electron energies ranging from 28 kev to 436 kev, by varying the scattering angle. The NE12 showed a good proportionality of light yield within 3% at energies between 9 kev and 436 kev. Below 9 kev, the light yield decreases by about 2% upon lowering the electron energy to 28 kev. The electron energy resolution of NE12 was also measured using this technique in energy range from 68 kev to 436 kev. It has been found that the energy resolution varies from 25.2% at 68 kev to 11.8% at 436 kev. Keywords: Plastic scintillator, Electron response, Energy resolution 1. INTRODUCTION Scintillation detectors are widely used in experimental nuclear physics, high energy physics, nuclear medicine,medical imaging, environmental studies, geological exploration and many other fields of use. Important requirements for the scintillation materials used in these applications include high light output, fast decay time of the light pulse, high stopping power, good energy resolution, good proportionality of light yield, minimal afterglow and low production costs. A good reviews on development of inorganics scintillators and inorganic scintillation detectors systems have been published by van Eijk[1],Moszynski[2], and recently by Lecoq et al.[3]. Plastic scintillators are widely used in detection and spectroscopy of charged particles and neutrons. Although its light output is lower than that of most inorganic scintillators, it has many advantages e.g. fast decay time of light pulse, non-hygroscopic, easy to fabricate in any shape and low costs. Light yield nonproportionality can be characterized as a function of either photon energy (photon response) or electron energy (electron response). Photon response is defined as the ratio of light yield to the energy deposited by photon. Similarly, electron response is defined as the ratio of light yield to the energy of the electron. While electron response is believed to be an intrinsic characteristic of a scintillation materials, very few studies have reported this scintillator characteristic. Porter at al.[4] have studied the electron response of NaI(Tl), anthracene and plastic(pilot B) scintillators using photomultiplier tube. They measured electron response nonproportionality by using external electron source(magnetic

The 1 st NPRU Academic Conference 89 spectrometer-energy selected electrons).the light yield response from external electron sources may be influenced by the surface effects in scintillators. The Compton Coincidence Technique(CCT) has been implemented for the purpose of characterizing NaI(Tl) light yield nonproportionality [5],[6]. Subsequently, the electron scintillation response of CaF 2, BGO, LSO, CsI(Tl), CsI(Na) and YAP were characterized using the CCT [7], [8]. This technique allowed a more accurate characterization of the electron response because the energetic electrons are produced internally in the scintillator by γ-rays. In this paper, the CCT has been firstly used to measure the electron response of plastic scintillator (NE12) 2.54x2.54 cm 3 covering energies from 28 kev to 43 kev. Consequently, the electron energy resolution has been determined over the energy range from 68 kev to 436 kev using the CCT measured energy spectra. 2. COMPTON COINCIDENCE TECHNIQUE A schematic of the Compton Coincidence Technique(CCT) used for measuring electron scintillation response is shown in Fig.1[6]. In this technique, the tested scintillator is exposed to a collimated beam of monoenergetic γ-rays of known energy E γ.some of the γ- rays will undergo a Compton scattering within the scintillator, transferring energy E e to an electron and exit the scintillator at some angle θ with energy E' γ, given by E γ Eγ = 2 1+ (Eγ / m c )(1 cosθ) where E γ is initial γ-ray energy and m c 2 is the rest mass energy of an electron. The Compton electron energy within the tested scintillator can be calculated by using conservation of energy, (1) E e = E γ E γ (2) The response of the scintillator to Compton electrons is recorded in coincidence with the Compton scattered photon detected by a secondary high-purity germanium(hpge) detector at a given angle defined by the next collimator. In CCT technique, the Compton electrons within the primary scintillation detector approximate a monoenergetic internal electron source and can be used to characterize the nonproportionality of scintillator light yield as a function of electron energy by using variable angle of the HPGe detector. Fig. 1 Schematic of the Compton Coincidence Technique(CCT)

9 The 1 st NPRU Academic Conference 3. EXPERIMENTAL PROCEDURES The plastic scintillator (NE12) used in this study was supplied by Nuclear Enterprise, England, with dimension of 1x1 inch 3.The plastic scintillator was first wrapped with several layers of Teflon tape and mounted to the RCA 8575 PMT using DC 2 silicone grease. The PMT with plastic scintillator was wrapped with black tape and covered with thin aluminum housing. In this study, a 25 mci 137 Cs source(e γ =662 kev) was placed about 5 cm. from plastic scintillator with 1 cm diameter collimators as indicated in Fig. 1. The 2x2 inch 3 NaI(Tl) detector was used to detect the Compton scattered gamma rays. Ten difference angle(θ) were used with the CCT to produce ten electron energies ranging from 28 kev to 436 kev. NaI(Tl) Detector 137 Cs Plastic Scintillator PMT PA AMP PC PA TSCA MCA Board AMP DL AMP GATE ADC PC 32 Bit I/O Board Fig. 2 Nuclear instrumentation used in the CCT. 7 6 5 NE12 137 Cs (E γ = 662 kev) Counts 4 3 2 1 2 4 6 8 1 12 Channel number Fig. 3 Energy spectrum of 662 kev γ-rays from 137 Cs source measured with NE12 scintillator.

The 1 st NPRU Academic Conference 91 1 8 NE12 E e = 68.2 kev Counts Counts 6 4 2 5 4 3 2 1 FWHM 52.% 2 4 6 8 1 12 Channel number FWHM 22.5% NE12 E e = 248.4 kev 2 4 6 8 1 12 Channel number Counts 25 2 15 1 5 2 4 6 8 1 12 Channel number NE12 E e = 412.7 kev FWHM 15.2% Fig. 4 Energy spectra of Compton electrons with the indicated energies for NE12 scintillator measured with the CCT. A schematic of the nuclear instrumentation used in this study is shown in Fig.2. The signal from NaI(Tl) detector was passed to a preamplifier, amplifier and then to a timing single channel analyzer(tsca). The TSCA output was used to gate the plastic scintillator analog-to-digital convertor(adc). The electron energy spectra from the plastic scintillator in coincidence with the Compton scattered gamma rays were then recorded using a 32 Bit I/O

92 The 1 st NPRU Academic Conference board in the computer. A multichannel analyzer board(mca board) in the second computer was used to record the entire energy spectra of the Compton scattered gamma rays at various scattering angles. The coincidence electron energy spectrum for the plastic scintillator was a Gaussian shaped peak. For each electron peak, the centroid and full width at half maximum(fwhm) of the full energy peak were obtained from Gaussian fitting software of Canberra MCA. 4. RESULTS AND DISCUSSION Fig.3 presents the energy spectrum of 662 kev γ-rays from a 137 Cs source measured with NE12 plastic scintillator. One first notices that the pulse height distribution is shaped by the Compton scattered electrons and there is no full energy peak in the γ-ray spectrum. Fig.4 presents some of the Compton electrons with the indicated energies for NE12 scintillator measured in coincidence with the Compton scattered γ-rays at energies 68, 248 and 413 kev, respectively. 1 Light output (a.u.) 8 6 4 2 1 2 3 4 5 Electron energy (kev) Fig. 5 Light output of NE12 scintillator as a function of electron energy.the solid line is the fit to points above 16 kev Light output (a.u.) 3.5 3 2.5 2 1.5 1.5 5 1 15 2 Electron energy (kev) Fig. 6 Expansion of Fig.5. Light output as a function of electron energy,for energies up to 167 kev.

The 1 st NPRU Academic Conference 93 Fig.5 shows the relative light output(proportional to the centroid of the electron peak) as a function of the electron energy. The solid line is determined by the points above 16 kev. Expansion of the low energy region is shown in Fig.6. The CCT measured electron response for NE12 plastic scintillator is shown in Fig.7. These results are normalized to unity at 436 kev. These results indicated a nearly proportional electron response above 9 kev (~3% change). Below 9 kev, the electron response decreases more significantly indicating a larger light yield nonproportionality for the low energy electrons. The electron response decreases about 2% over the measured energy range. Below 28 kev, accurate electron response measurements were not achievable due to photomultiplier thermal noise and the relatively low light yield of plastic scintillator. Consequently, the electron response below 28 kev is not reported in this study. 1.2 1.1 Electron response, Re 1.9.8.7.6.5.4 1 1 1 Electron energy (kev) Fig. 7 Electron response of NE12 plastic scintillator measured using CCT and normalized to unity at 436 kev. 1 η e = 29.64e -.2E e Energy resolution (%) 1 Total Geometric Component, η g Electron energy resolution, η e 1 1 2 3 4 5 Electron energy (kev) Fig. 8 Electron energy resolution (η e ) of NE12 plastic scintillator determined using CCT. Also shown is the geometric component (η g ) due to finite solid angle subtended by the NaI(Tl). The total NE12 electron energy resolution is shown for comparison.

94 The 1 st NPRU Academic Conference.1 Porter at.al.[4] measured the electron response of plastic(pilot B) scintillators,for and.6 thick samples, coupled to a PMT. They exposed the detectors to a magnetic spectrometer-energy-selected electrons and measured a nonproportionality effect of ~5% and ~2%, respectively for.1 and.6 thick samples, in the energy range from 2 to 1 kev and a flat behavior in the energy range from 1 to 35 kev. The electron energy resolution, η e defined as the ratio between the full width at half maximum and the peak position, for the electron energy range from 68 to 436 kev, was also measured. In Fig.8 the electron energy resolutions are plotted versus the electron energies. The geometric broadening η e of the measured coincidence spectrum due to the range of electron energies associated with the finite solid angle subtended by the NaI(Tl) detector in CCT was also determined in analysis and is shown in Fig. 8. It is observed that the geometric component is significant at electron energies below about 15 kev. The energy resolution of plastic scintillator η e decreases exponentially with electron energy. Below 68 kev, accurate energy resolution measurements were not achievable due to photomultiplier noise and the relatively low light yield of plastic scintillator. Consequently, the energy resolution below 68 kev is not reported in this study. 5. CONCLUSIONS In this study the electron response for plastic scintillator(ne12) has been measured using CCT for electron energies ranging from 28 kev to 436 kev. The electron response of plastic scintillator was observed to increase monotonically with increasing energy. The light yield becomes proportional to within 3% at energies above about 9 kev. Below 9 kev, the electron response decreases by about 2% upon lowering the electron energy to 28 kev. The electron energy resolution for plastic scintillator has been measured using CCT for electron energies ranging from 68 kev to 436 kev. The measured energy resolution decreases exponentially with increasing electron energy. It varies from 25.2% at 68 kev to 11.8% at 436 kev. Further investigations of the intrinsic energy resolution and light yield non proportionality of the crystals are in progress, especially with inorganic scintillators by using Compton Coincidence Technique(CCT). 6. REFERENCES [1] van Eijk, C. W. E. (21). Inorganic-scintillator development. Nucl. Instrum. Methods. Phys. Res., A46, 1-14. [2] Moszynski, M. (23). Inorganic scintillation detectors in γ-ray spectrometry. Nucl. Instrum. Methods. Phy.s Res., A55, 11-11. [3] Lecoq, P., Annenkov, A., Gektin, A., Korzhik, M.,& Pedrini, C. (26). Inorganic scintillators for detector systems. The Netherlands: Springer. [4] Porter, F. T., Freedman, M. S., Wagner, F., Jr., & Sherman, I. S. (1966). Response of NaI, anthracene and plastic scintillators to electrons and the problems of detecting low energy electrons with scintillation counters. Nucl. Instrum. Methods, 39, 35-44. [5] Rooney, B. D., & Valentine, J. D. (1996). Benchmarking the Compton Coincidence Technique for measuring electron response nonproportionality in inorganic scintillators. IEEE Trans. Nucl. Sci., 43(3), 1271-1276. [6] Rooney, B. D., & Valentine, J. D. (1994). Design of a Compton spectrometer experiment for studying scintillator nonlinearity and intrinsic energy ersolution. Nucl. Instrum. Methods, A353, 33-7.

The 1 st NPRU Academic Conference 95 [7] Taulbee, T. D., Rooney, B. D., Mengesha, W. & Valentine, J.D. (1997). The measured electron response nonproportionalities of CaF 2, BGO, and LSO. IEEE Trans. Nucl. Sci., 44, 489-493. [8] Mengesha, W., Taulbee, T. D., Rooney, B. D., & Valentine, J. D. (1998). Light yield nonproportionality of CsI(Tl), CsI(Na), and YAP. IEEE Trans. Nucl. Sci., 45, 456-461.