S reacts with the catalyst s metallic surface to substitute sulfur atoms for oxygen atoms.

Similar documents
S is referred to as sour. The sulfide loading lends an unpleasant odor and makes the water corrosive. Additionally, the presence of H 2

Monitoring Nitrogen Trichloride in Chlorine Manufacture. solvent. O NaOH + 1 /2H 2

APPLIED. Measuring Proof and Color in Whiskey. Application Summary. Analytes: ethanol concentration, product color. Detector: OMA-300 Process Analyzer

SULFUR RECOVERY ANALYZERS; UV Diode-Array Fiber- Optics Technology

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

A Powerful New Diagnostic Tool for Transit Time Ultrasonic Meters page 1. A Powerful New Diagnostic Tool for Transit Time Ultrasonic Meters

Cyanide Analysis of Wastewater Samples from FCC and Hydrocracking Operations

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

INDUSTRY GUIDANCE. REACH for catalysts. 1. Introduction. 2. Fresh catalysts. 3. Active catalysts

of mass spectrometry

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Prima PRO Process Mass Spectrometer

Application Note S/SL

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

SST Tag: Message: (32 characters)

AN2970 Application note

White Paper. Overview: NDIR Definition:

Aviation Fuel Production from Lipids by a Single-Step Route using

TRACERCO Diagnostics FCCU Study

Defining quality standards for the analysis of solid samples

Expanded capabilities in ammonium and amine detection

Dräger simultaneous test sets Dräger-Tubes

LD29300xx. 3 A, very low drop voltage regulators. Features. Description

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

3 rd Generation Stabilized Front End Selective Hydrogenation Catalysts Enhance Operational Stability and Maximize Ethylene Gain

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

The Fundamentals of Moisture Calibration

for XPS surface analysis

Reprinted from February Hydrocarbon

SCR Catalyst Layer Addition Specification and Management

Order codes Part numbers DPAK (tape and reel) PPAK (tape and reel)

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Bindzil CC in the coating industry. Silane modified colloidal silica dispersions functions and applications

MIL-PRF-39035, Char. H with a Smooth and Unidirectional Output

AND8149/D. Understanding and Using the NCV1124 VR Sensor Interface APPLICATION NOTE

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

AN922 Application note

Spectrophotometric quantification of nucleic acids using the nanovette microliter cell accessory with a DU 730 spectrophotometer

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

MetWorks Metabolite Identification Software

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization

Modeling and Simulation of Fluidized Bed Catalytic Reactor Regenerator

Introduction to Fourier Transform Infrared Spectroscopy

Application Note XSP-AN-005. Determination of Ultra Low Chlorine (and Sulfur) in Oil. X-Supreme8000. Key Benefits

Introduction to Fourier Transform Infrared Spectroscopy

Far UV Absorbance Detector

on-line analyzer systems for safety and control of chlorine production plants by Chris Du Bois by Thibaut Bettini Buenos Aires Argentina Nov.

Oxygen Demand, Chemical

TECHNICAL DATASHEET OVIVO ANALYZER UREA Ovivo Switzerland AG Hauptstrasse 192 CH 4147 Aesch Switzerland

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

ISA QATAR : 90 th Seminar

MEASURING H 2 S IN CRUDE OIL FOR QUALITY CONTROL & TRANSPORTATION SAFETY

Organic Polymer Feeding

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Bulk Metal Foil Technology Power and Current Sensing Resistors with TCR of 2 ppm/ C, Tolerance to ± 0.01 % and power up to 10 W

L78LxxAB L78LxxAC - L78LxxC

HCMOS 7x5mm SMD Oscillator O7HS (former F4500, F4400, F4100 Series) DATASHEET

LAB 05 Enzyme Action

HCMOS 5.0x3.2mm SMD Oscillator O5HS DATASHEET (Former F510L, F540L, F530L, F550L Series)

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

FEATURES MAXIMUM - 55 C MAXIMUM

Polymer plants continue to seek ways to increase production and efficiency without compromising safety.

SOUR WATER ANALYSIS USING A DUAL- COLUMN HEADSPACE SAMPLING SYSTEM

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Ideal and powerful solution

Obsolete Product(s) - Obsolete Product(s)

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

INFORMATION NOTIFICATION

THE APPLICATION OF PROCESS MASS SPECTROMETRY TO FUMED SILICA PRODUCTION

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

Measurement Technique and its Application to Trace Components of Atmospheric Gas

V N (8) V N (7) V N (6) GND (5)

Aspen Polymers. Conceptual design and optimization of polymerization processes

Recovering MC56F8300 Family Devices from Extreme RFI

NSVJ6904DSB6. Advance Information N-Channel JFET 25 V, 20 to 40 ma, 40 ms, Dual

Elemental Analysis: CHNS/O characterization of polymers and plastics

DG Filters 2500 Series Refilling Instructions

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

STTH6110TV. Ultrafast recovery - high voltage diode. Main product characteristics. Features and benefits. Order codes. Description ISOTOP ISOTOP

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

XR Analog Clock - Manual Setting Model Troubleshooting Guide

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Oxygen Demand, Chemical

Fast, Effective XPS Point Analysis of Metal Components

Highest Precision. DASGIP PHPO, GA and OD4 for monitoring and control of bioprocesses

Corrosion-Resistant Polyester Resins

KD A LOW DROP POSITIVE VOLTAGE REGULATOR ADJUSTABLE AND FIXED

KNOWLEDGE

Monitoring Flammable Vapors and Gases in Industrial Processes

Transcription:

Application Summary Analytes: S (hydrogen sulfide), sulfiding agent Detector: OMA-300 S Analyzer Process Stream: reactor effluent gas Introduction Catalyst presulfiding is a practice which reduces the extent of early catalyst deactivation by preventing coking (carbon deposits). The procedure involves passing a gas stream containing S over the catalyst or into the reaction feedstock. In order to generate the S which will interact with the catalyst, a sulfur carrying agent (e.g. dimethyl sulfide) is injected into the stream. Under high temperature and catalytic reaction, the agent decomposes and releases its sulfur component, forming S. The S reacts with the catalyst s metallic surface to substitute sulfur atoms for oxygen atoms. The importance of presulfiding is clear, yet the procedure needs to be actively regulated in order to reduce costs and downtime. For example, the presulfiding procedure normally takes 10-36 hours, but can be reduced if presulfiding is terminated as soon as the catalyst is properly sulfided; this can be easily verified by measuring S concentration in the stream after the reactor (if S concentration does not drop when injection is ceased, presulfiding is complete). The OMA-300 Process Analyzer monitors S and additional analytes at specific sampling points which are critical to the optimization of presulfiding. Measuring real-time S levels downstream from the reactor validates the completion of presulfiding; additional measurements include low level S after the dryer system and continuous measurement of sulfiding agent concentration in order to detect fluctuations due to outages. OMA Benefits Continuously measures S concentration using dispersive UV-Vis absorbance spectrophotometer Totally solid state build with no moving parts modern design for low maintenance Easily multiplexed to analyze sample streams from multiple sampling points Decades of field-proven performance in various catalytic processes, e.g. propane dehydrogenation APPLIED TM A N A L Y T I C S [1]

Presulfiding Analysis Applications The schematic below illustrates the example of a propane dehydrogenation process, identifying key analysis applications for optimization of the presulfiding step: The analyzer sampling from the stream after REACTOR 1 serves to validate the presulfiding procedure in real time. Continuous analysis at this point allows the OMA to quickly recognize the completion state and alert the control system so that no superfluous time or resources are dedicated to presulfiding. The analyzer sampling from the stream after the dual dryer system serves to verify scrubbing efficiency and ensure that no S is contaminating the propylene product or the recycle stream. Additional analysis points can be implements in the sulfiding agent stream to continuously watch for outages or problematic fluctuations that will prevent healthy catalyst operation. [2]

S Absorbance Curve Any single photodiode measurement is vulnerable to noise, signal saturation, or unexpected interference. This susceptibility to error makes a lone photodiode data point an unreliable indicator of one chemical s absorbance. As accepted in the lab community for decades, the best way to neutralize this type of error is to use collateral data in the form of confirmation wavelengths, i.e. many data points at many wavelengths instead of a single wavelength: In the figures above, each diamond represents a single photodiode and data point. The Nova II registers absorbance at each integer wavelength within the 200-240 nm measurement range and produces an S absorbance curve. After being calibrated on a full spectrum of an S calibration standard, the OMA knows the absorbance-concentration correlation for each measurement wavelength; the system can average the modeled concentration value from each wavelength to completely eradicate the effect of noise at any single photodiode. The OMA visualizes the S absorbance curve in this manner and knows the expected relation of each data point to the others in terms of the curve s structure. This curve analysis enables the OMA to automatically detect erroneous results at specific wavelengths, such as when a single photodiode is saturated with light. The normal photometer, with a single data point, is completely incapable of internally verifying its measurement. [3]

The specifications below represent performance of the OMA-300 Process Analyzer in a typical presulfiding application. For technical details about the OMA-300 Process Analyzer, see the data sheet: http://aai.solutions/documents/aa_ds001a_oma300.pdf All performance specifications are subject to the assumption that the sample conditioning system and unit installation are approved by Applied Analytics. For any other arrangement, please inquire directly with Sales. Subject to modifications. Specified product characteristics and technical data do not serve as guarantee declarations. Application Data Performance Specifications Accuracy Example ranges below. Custom ranges available. Accuracy may be higher at higher pressure. Example ranges below. Custom ranges available. Accuracy may be higher at higher pressure. 0-10 ppm (@1 bar): ±1 ppm (Increased pressure will yield increased accuracy); ±0.2 ppm (@5 bar) 0-100 ppm: ±1% full scale or 1 ppm* S 0-10,000 ppm: ±1% full scale 0-100%: ±1% full scale COS 0-200 ppm:: ±2% full scale or 4 ppm* CS 2 0-200 ppm:: ±2% full scale or 4 ppm* *Whichever is larger. [4]

Revised 14 April 2017 Further Reading Subject OMA-300 H2S Analyzer Brochure OMA-300 Process Analyzer Data sheet Advantage of Collateral Data Technical Note Multi-Component Analysis Technical Note Location http://aai.solutions/documents/omah2s.pdf http://aai.solutions/documents/aa_ds001a_oma300.pdf http://aai.solutions/documents/aa_tn-202_collateraldata.pdf http://aai.solutions/documents/aa_tn-203_multicomponentanalysis.pdf is a registered trademark of Applied Analytics, Inc. www.aai.solutions Headquarters Applied Analytics, Inc. Burlington, MA sales@aai.solutions North America Sales Applied Analytics North America, Ltd. Houston, TX sales@appliedanalytics.us Asia Pacific Sales Applied Analytics Asia Pte. Ltd. Singapore sales@appliedanalytics.com.sg Middle East Sales Applied Analytics Oil & Gas Operations, L.L.C. Abu Dhabi, UAE sales@appliedanalytics.ae India Sales Applied Analytics (India) Pte. Ltd. Mumbai, India sales@appliedanalytics.in Europe Sales Applied Analytics Europe, AG Genève, Switzerland sales@appliedanalytics.eu Brazil Sales Applied Analytics do Brasil Rio de Janeiro, Brazil vendas@aadbl.com.br 2017 Applied Analytics, Inc. Products or references stated may be trademarks or registered trademarks of their respective owners. All rights reserved. We reserve the right to make technical changes or modify this document without prior notice. Regarding purchase orders, agreed-upon details shall prevail. [5]