Non-Destructive Evaluation of Multi-Layer Actuators

Similar documents
ACOUSTIC EMISSION MEASUREMENTS ON PIEZOELECTRIC/ FERROELECTRIC MATERIALS

Laser Interferometric Displacement Measurements of Multi-Layer Actuators and PZT Ceramics

Piezoelectric Resonators ME 2082

Characterisation of barium titanate-silver composites part II: Electrical properties

Solid State Physics (condensed matter): FERROELECTRICS

Time temperature profiles of multi-layer actuators

Sensor Measurements For Diagnostic Equipment

Methods Based on the Phenomenon of Elastic Wave Propagation (Guided Waves) Interaction with Damage

Temperature Dependence of the Dielectric, Elastic and Piezoelectric Material Constants of Lead Zirconate Titanate Ceramics

Finite Element Modeling of Ultrasonic Transducers for Polymer Characterization

Lamb Waves in Plate Girder Geometries

Single-phase driven ultrasonic motor using two orthogonal bending modes of sandwiching. piezo-ceramic plates

LAMB WAVES GENERATION USING A TRANSDUCER EMBEDDED IN A COMPOSITE PLATE

Dae Won Ji and Sang-Joo Kim

Chapter 2 Surface Acoustic Wave Motor Modeling and Motion Control

Friction Drive Simulation of a SAW Motor with Slider Surface Texture Variation

Characterization and modelling of 3D piezoelectric ceramic structures with. ATILA software.

An Acoustic Emission Approach to Assess Remaining Useful Life of Aging Structures under Fatigue Loading PI: Mohammad Modarres

PIEZOELECTRIC TECHNOLOGY PRIMER

Quan Wang a, Yuanxin Xi a, Zhiliang Wan a, Yanqing Lu a, Yongyuan Zhu a, Yanfeng Chen a & Naiben Ming a a National Laboratory of Solid State

Lamb Wave Behavior in Bridge Girder Geometries

Optimisation of interdigitated electrodes for piezoelectric actuators and active fibre composites

RS INDUSTRY LIMITED. RS Chip Array ESD Suppressor APPROVAL SHEET. Customer Information. Part No. : Model No. : COMPANY PURCHASE R&D

Concrete cure monitoring using piezoelectric admittance measurements

Joshua Whittam, 1 Andrew L. Hector, 1 * Christopher Kavanagh, 2 John R. Owen 1 and Gillian Reid 1

1 INTRODUCTION 2 SAMPLE PREPARATIONS

BIASED PZT MATERIALS FOR ACOUSTIC TRANSDUCERS

Epitaxial piezoelectric heterostructures for ultrasound micro-transducers

Design of Power Electronics Reliability: A New, Interdisciplinary Approach. M.C. Shaw. September 5, 2002

A coupled field finite element model to predict actuation properties of piezoelectrically actuated bistable composites.

Development of Lead-Free Piezoceramics and Implementation in Multilayer Actuators

The Relationship between the Applied Torque and Stresses in Post-Tension Structures

NUMERICAL EVALUATION OF A TEFLON BASED PIEZOELECTRIC SENSOR EFFECTIVITY FOR THE MONITORING OF EARLY AGE COCRETE STRENGTHING

Acoustic Emission Source Identification in Pipes Using Finite Element Analysis

DAMPING CONTROL OF A PZT MULTILAYER VIBRATION USING NEGATIVE IMPEDANCE CIRCUIT

Sensors and Actuators A: Physical

Sensors & Transducers 2016 by IFSA Publishing, S. L.

Intelligent Materials and their applications. Autors: Jana Pintea, Ionut Balan INCDIE ICPE-CA Bucharest, ROMANIA

An Approach to Designing a Dual Frequency Piezoelectric Ultrasonic Transducer

Non-linear Properties of Piezoelectric Ceramics

Fundamental Study of a Stacked Lithium Niobate Transducer

Ultrasonic Monitoring and Evaluation of Very High Cycle Fatigue of Carbon Fiber Reinforced Plastics

440. Simulation and implementation of a piezoelectric sensor for harmonic in-situ strain monitoring

Dual Extraction of Photogenerated Electrons and Holes from a Ferroelectric Sr 0.5 Ba 0.5 Nb 2 O 6 Semiconductor

Micro/nano and precision manufacturing technologies and applications

Degradation of Piezoelectric Materials for Energy Harvesting Applications

7.Piezoelectric, Accelerometer and Laser Sensors

PIEZOELECTRIC ceramics for advanced actuator applications often

Development of water immerse type ultrasound probe with PZT film deposited by hydrothermal method

Piezo materials. Actuators Sensors Generators Transducers. Piezoelectric materials may be used to produce e.g.: Piezo materials Ver1404

In Situ Ultrasonic NDT of Fracture and Fatigue in Composites

Durability and Survivability of Piezoelectric Wafer Active Sensors Mounted on Aluminum Structures for Aerospace Vehicle Health Monitoring

Proceedings of Meetings on Acoustics

Lorentz Contact Resonance for viscoelastic measurements of polymer blends

[Yadav*, 5(3): March, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Dielectric Properties of Composite Films Made from Tin(IV) Oxide and Magnesium Oxide

Specification for Embedded Passive Device Capacitor Materials for Rigid and Multilayer Printed Boards

Lorentz Contact Resonance for viscoelastic measurements of polymer blends

Characterization of Multilayer Piezoelectric Actuators for Use in Active Isolation Mounts

EIS of Organic Coatings and Paints

I. INTRODUCTION II. SAMPLE PREPARATION JOURNAL OF APPLIED PHYSICS VOLUME 92, NUMBER 5 1 SEPTEMBER

Multilayer Ceramic Capacitors: Mitigating Rising Failure Rates

Piezoelectric response of porous ceramic and composite materials based on Pb(Zr,Ti)O 3 : experiment and modelling

Transducer Design and Modeling 42 nd Annual UIA Symposium Orlando Florida Jay Sheehan JFS Engineering. 4/23/2013 JFS Engineering

Doppler echocardiography & Magnetic Resonance Imaging. Doppler echocardiography. History: - Langevin developed sonar.

FEM Simulation of Generation of Bulk Acoustic Waves and Their Effects in SAW Devices

PERFORMANCE OF HYDROTHERMAL PZT FILM ON HIGH INTENSITY OPERATION

Nanomechanics Measurements and Standards at NIST

ULTRASONIC MEASUREMENT OF IN-PLANE MODULI OF PULTRUDED COMPOSITES

Proceedings Effect of Electrode Configuration on High Temperature Thickness Shear Gallium Phosphate Transducer

VIBRO-THERMOGRAPHY OF DEBONDING DEFECTS IN COMPOSITE PLATES

Available online at ScienceDirect. Physics Procedia 70 (2015 )

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

RP 2.7. SEG/Houston 2005 Annual Meeting 1525

Applicability of Self-Powered Synchronized Electric Charge Extraction (SECE) Circuit for Piezoelectric Energy Harvesting

MATERIALS CHARACfERIZA TION USING ACOUSTIC NONLINEARITY PARAMETERS AND HARMONIC GENERATION: ENGINEERING MATERIALS. William T. Yost

ESL. Frequency ESR. Geometry AEC-Q200 IEC Capacitors. Insulation Current. Vibration. Temperatur Change Environmental Testing

Conventional Paper-I-2011 PART-A

INTERNAL STRAIN MEASUREMENTS IN CFRP PLATES SUBJECTED TO IMPACT LOAD USING FBG SENSORS

IMECE SINGLE CRYSTAL PIEZOELECTRIC ACTUATORS FOR ADVANCED DEFORMABLE MIRRORS

Ultrasonic and optical stimulation in IR thermographic NDT of impact damage in carbon composites

CERAMIC CHIP CAPACITORS

1990. Temperature dependence of soft-doped / hard-doped PZT material properties under large signal excitation and impact on the design choice

Dielectric, Piezoelectric and Nonlinear Optical Properties of Lead Titanate based Ferroelectric Thin films

Ultrasonic linear actuator using coupled vibration

Thermal Analysis of a piezo-disk ultrasound probe

High speed and quick response precise linear stage system using V-shape transducer ultrasonic motors

Electromagnetic Acoustic Transducers for In and Out of plane Ultrasonic Wave Detection

Active elastomer components based on dielectric elastomers

Testing and analysis of high frequency electroelastic characteristics of piezoelectric transformers

Quartz Crystal Resonator Parameter Calculation Based on Impedance Analyser Measurement Using GRG Nonlinear Solver

Structural Health Monitoring Using Smart Piezoelectric Material

EXPERIMENTAL AND NUMERICAL ANALYSIS OF A TRANSDUCER FOR THE GENERATION OF GUIDED WAVES

Multilayer Ceramic Chip Capacitors

Quality & Reliability Data

Barrier Layer; PTCR; Diffuse Ferroelectric Transition.

High-performance machining of fiber-reinforced materials with hybrid ultrasonic-assisted cutting

Physical and Dielectric Properties of Silver Lithium Niobate Mixed Ceramic System

Ultrasonic resonance of defects for nonlinear acoustic imaging and NDT

Concrete Strength Evaluation Based on Non-Destructive Monitoring Technique using Piezoelectric Material

Transcription:

Ferroelectri,-r. 2000, Vol. 241, pp. 19Y-206 Reprint?. available directly from the puhlisher Photocopying permitted by license only 0 2000 OPA (Overseas Publishers Association) N.V. Published by license under the Gordon and Breach Science Publishers imprint. Printed in Malaysia Non-Destructive Evaluation of Multi-Layer Actuators CHRISTOPHER RHYS BOWENa, STEVE MAHONb and MARTA LOPEZ PRIETOa adepariment of Materials Science & Engineering, University of Bath, BA2 7AI: UK and bmss, DERA Farnborough, UK, GUI4 OLX. (Received July 12, 1999) This paper describes the use of impedance spectroscopy as a means of non-destructively detecting delaminations and damage in piezoelectric multi-layer actuators. The method is based on a test developed to examine multi-layer capacitor devices. Impedance spectra are reported on conventional multi-layer actuators and multi-layers that contain delaminations or have been subjected to damage. The defects within the devices are characterised by ultrasonic evaluatior and microscopy. Impedance analysis reveals that the resonance hehaviour of the actuator is altered by the presence of defects. By examining impedance data using a complex impedana: plot the change in resonance behaviour of a multi-layer actuator due to defects can be observed. The method could be employed as a means of quality control during production 01, for monitoring the state of the actuator whilst in service, e.g. whether there has been fatigie of the device or it has be subjected to an unacceptably high stress. Keywords ' actuator; impedance; multi-layer; piezoelectric; non-destructive evaluation; resonance; delamination INTRODUCTION Multi-layer actuators (MLAs) are used to provide large displacements compared to monolithic materials, at low drive voltage (50-2OOV) and low power consumption. However. due to the composite structure of these devices and the electrode configuration, MLAs can suffer from fatigue and degradation of performance as a hnction of time [ 1-41. It [ 1843]/199

2004 18441 CHRISTOPHER RHYS BOWEN et al. has been reported that fatigue of MLAs is due to the development of internal stresses around the inactive and active regions of the piezoelectric material at the electrode edges [5,6]. In addition to fatigue, a concern of MLA manufacturers is delamination of the electrode layers during processing which can act as nuclei for crack propagation. Mechanisms of delamination during processing are binder burnout, green state delamination due to inadequate adhesion of the electrode and piezoelectric layer, catalytic reactions of electrode metals with organic additives during burnout and sintering shrinkage mismatch [7]. Therefore, there is a need to detect defects during production and to detect the development of fatigue damage during service (selfvalidation) in a simple and rapid manner. Non-destructive testing methods to assess the reliability of MLAs have included direct measurement of insulation resistance (IR), induced displacement and acoustic emission which have been used with some success to monitor damage and degradation of MLAs [ 1,3]. The most promising technique is frequency response analysis, or impedance spectroscopy (IS), which examines the change in resonance characteristic as the degree of damage increases in the device [8-111. The aim of this paper is to examine the change in resonance behaviour of typical MLAs due to the presence of delaminations andor cracks introduced into the device. The ability of IS to detect delaminations and damage will be verified by Cscan ultrasonic imaging, which is widely used to detect delaminations in structural composites. Finally. there will be direct observations of defects using optical and scanning electron microscopy of sectioned devices. In addition to examining processing induced defects, damage will also be deliberately introduced into the devices. Various methods used to present impedance data such as Bode diagrams or complex plane (Nyquist plot) will be examined to determine which is most applicable in examining any change in resonance characteristics of an MLA due to damage. EXPERIMENTAL Multi-layer actuators were supplied by Morgan Matroc Unilator Division, a commercial supplier of piezoelectric materials and actuators, who deliberately supplied and fabricated a range of multi layer actuators for this research. The MLAs had a cross section of lorn x 1 Omm and a thickness of 2mm. consisting of 30 electrodes with an electrode spacing of approximately 85pm through the thickness. The actuators were fabricated from PZT-SH, a soft piezoelectric material.

NON-DESTRUCTIVE EVALUATION OF MULTI-LAYERS [ 1845]/201 Impedance spectroscopy was undertaken using a Solatron 1260 Frequency Response Analyser and 1296 Dielectric Interface. A small sinusoidal AC signal of 0.1V was applied to the device in a frequency range above and below the resonant frequency of the device. The resonant frequency was determined from a calculation based on the dimensions of the actuator (assuming width resonance) and an initial fiequency sweep. The resonance frequency was typically 185kHz for the samples of the dimension and material used in this study. Ultrasonic Cscan imaging was carried out in a water bath contairdng focussed 5MHz transducers and receivers. The ultrasound was passed through the cross section of the actuator, i.e. applied to the lomm x lomm surface. as delaminations often occur along the electrodes. An x-y stepper motor and data acquisition software were used to measure signal attenuation and sample position. Defects were deliberately introduced into the actuators using a Vickers indentation testing machine at a range of applied loads. Destructive sectioning and final device inspection was undertaken using a diamond cutting wheel, polishing to Ipm with diamor,d paste and subsequent examination using optical microscopy and Scmning Electron Microscopy (SEM) using a JEOL T330. RESULTS Figure 1 a is a graph of the modulus of impedance, I Z I. of two MLAs as a function of frequency. The parallel resonance fiequency, where the impedance is at a maximum is located at 185kHz, which is similar to values based on the equationf =ii2tm for width resonance, where f is fiequency, p is density (7500 kg m ), t is actuator width (IOmm) and sei I is compliance (16 x lo- Pa- ). It can be seen that there is a large difference in the impedance as a fimction of fiequency for the two actuators tested. One actuator has a severely damped resonance spectrum and a correspondingly low modulus of impedance at parallel resonance, compared to the other actuator. This is also indicated by the values of the mechanical quality factor Qm, which are shown in Figure la. Based on the assumption that defects will damp the resonance of the actuato; the damped actuator with low maximum modulus of impedance and Qm will now be labelled delaminated while the actuator with sharp resonance will be labelled good. The resonance behaviour is also observed in the measurement of phase angle (8) as a function of fiequency (Figure 1 b).

2024 18461 CHRISTOPHER RHYS BOWEN et al. 130 155 180 205 Frequency (khz) (a) FIGURE 1 100 I 130 155 180 205 Frequency (khz) 0-9 I I I Modulus of impedance, lzl (a) and phase angle, 0 (b) as a function of frequency for a good and delaminated MLA. The good actuator is indicated by the arrow. - Delannnatedachrafor Goodadratcw %, J C 183kHz 0 25 50 75 Z (ohm) FIGURE 2 Nyquist plot of a good and delaminated actuator. The good actuator is indicated by the arrow.

NON-DESTRUCTIVE EVALUATION OF MULTI-LAYERS [ 184711203 The difference between the phase angle for the 'good' and 'delaminated' actuator is, however, small in comparison to modulus of impedance-frequency behaviour in Figure 1 a. The differences observed in IZI and 8 can be combined by constructing a complex impedance plot (Nyquist) of Z'versus Z", where Z'=IZlcos@, the real part of the impedance and Z"=lzlsine, the imaginary part of the impedance. A Nyquist plot is shown in Figure 2 in whkh a complete circle is observed as the device passes through resonance frequency. The intercept of the circle with the Z' axis is equivalent to the maximum in impedance of the Bode diagram. Therefiire, delaminated and damped multi-layers exhibit smaller diametx complex impedance plots, as can clearly be seen in Figure 2. The advantage of the complex method of presentation is that small changes in resonance characteristics are readily observed and detected compared to the Bode presentation. To validate that IS was accurately detecting defects in MLAs, the actuators were also examined by ultrasonic Cscan and microscopy. Figure 3 shows Cscan images of the two actuators. The 'good' actuator (as determined by IS) in Figure 3a shows the greatest attenuation of ultrasomd and exhibits a clear uniform Cscan image. The 'delammated' actuator, shown in Figure 3b, has less attenuation and a non-uniform Cscan image, which is indicative of the presence of defects or delamination. The results are therefore in agreement with the 1s measurements. It should be noted that a number of samples were analysed by IS and Cscan with good agreement and the results are to be reported elsewhere [12]. The nature of the defects in the actuators was finally determined by sectioning the MLAs and examining microscopically. Figure 4a is an SEM image of the MLA with the damped resonance and the non uniforni Cscan. Delaminations can be clearly observed. The 'good' actuator (Figure 4b) with a sharp resonance and uniform, high attenuation has no observable defects. These observations imply that impedance spectroscopy is a possible technique of rapidly electrically detecting the presence of defects in multi-layer actuators. To provide additional evidence that defects can change the impedance response of a multi-layer actuator, damage was deliberately and systematically introduced into an MLA and the subsequent change in resonance monitored. Figure 5 shows the change in Nyquist plot of a MLA as Vickers indents are introduced into the device. The diameter of the complex impedance plot is reduced, and therefore the degree of damping increases, as damage is systematically introduced into the device.

2044 18481 CHRISTOPHER RHYS BOWEN et al. - 96-120 72-96 46-72 24-48 06-24 5 mm Figure 3. Cscan images of (a) good and (b) delaminated actuators. The legend indicates signal strength. The impedance data of the actuators are shown in Figures 1 and 2. See Color Plate I11 at the back of this issue. -50-25 -0 E C 0 Y 50 Figure 5. Nyquist plots with indentation defects introduced into an MLA. Diameter and intercept with Z axis decreases as damage increases. Frequency range 150kHz - 2 1 OkHz. See Color Plate IV at the back of this issue.

NON-DESTRUCTIVE EVALUATION OF MULTI-LAYERS [1849]/205 FIGURE 4 SEM images of (a) delaminated and (b) good actuators. CONCLUSIONS Impedance spectroscopy has shown to be a valuable technique in nondestructive determination of the presence of defects and delaminations in multi-layer actuators. The test has been used to detect defects induced by processing (such as delaminations) and deliberately induced defects (by indentation). Ultrasonic Cscan imaging, sectioning and microscopic examination have verified the predictions made by impedance spectroscopy. 1 mpedance spectroscopy detects damage by using the damping nature cf the defect and the resultant change in the resonance behaviour of the h4la. The examination of impedance-fkequency data in the form of a Nyquist plot has shown to be the most useful in rapidly determining small changes in resonant behaviour. 1 f the resonance ffequency of the MLA is known, the impedance spectrum and the health of the actuator can be determined in

206/[ 18501 CHRISTOPHER RHYS BOWEN et al. measurement times much shorter than imaging methods such as the Cscan. Rapid test times are of importance when the actuators are produced in large quantities. The test could be developed to detect delaminations and other defects during production andor the monitoring of fatigue during in-service operation. The technique is more suited for in-service monitoring (self-validation) compared to techniques, such as acoustic emission [3], as the electrical connections and circuits are already present to drive the actuators (provided that resonance is not prevented by any clamping of the MLA). Further work will evaluate the sensitivity of the technique and the types of defect detectable by impedance spectroscopy. Acknowledgements This work was carried out as part of Technical Group 04 of the MOD Corporate Research Programmes. The authors thank Morgan Matroc Unilator, Wrexham (UK) for manufacturing multi-layer actuators for this research and Prof. Darryl Almond for provision of the CScan. References [l] A. Furuta and K. Uchino, J. Am. Ceram. Soc., 76 1615-1617 (1993). [2] H. Aburatani, S. Harada, K. Uchino, A. Furuta and Y. Fuda, Jpn. J. Appl. Phys., 33 3091-3094 (1994). [3] H. Aburatani, S. Yoshikawa, K. Uchino and J.W.C. de Vries, Jpn. J. Appl. Phys., 37 204-209 (1998). [4] K. Uchino and S. Takahashi, Current Opinion in Solid Stare & Materials Science, 1 698-705 (1996). [5] S. Takahashi, A. Ochiai, M. Yonezawa, T. Yano, T. Hamastuki and I. Fukui, Ferroelectrics, 50 507-516 (1983). [6] X. Gong, Z. SUO, J. Mech. Phys. Sol., 44 751-769 (1996). [7] J.G. Peppin, W. Borland, P. O'Callaghan and R.J.S. Young, J. Am. Ceram. Soc., 72 2287-2291 (1989). [8] 0. Boser, P. Kellawon and R. Geyer, J. Am. Ceram. Soc., 72 2282-2286 (1989). [9] 0. Boser, Adv. Ceram. Mat., 2 167-172 (1987). [lo] B. Zickgraf, G.A. Schneider and F. Aldinger, ISAF '94-Proceedings of the gth IEEE International Symposium on Application of Ferroelectrics, Ch. 222, p.325-328 (1994). [ 111 B. Zickgraf, Ermiidungsverhalten von Multilayer-Aktoren aus Piezokeramik, Fortschrt-Berichte VDI, Reihe 18, Nr. 191. Diisseldorf, VDI Verlag 1996, ISBN 3-18- 319118-8. [ 121 C.R. Bowen and M. Lopez Prieto, to be submitted to J. Euro. Ceram. Soc.