Synthesis and Use of a New Covalently Bonded C18 Modified Carbon Clad Microporous Zirconia for Fast High Temperature Separations

Similar documents
Retention and Selectivity Variables

Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

The Development of ZrO 2 Based HPLC: From Colloid to Column

Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

Characteristics and Advantages of Zirconia-Based Stationary Phases for Use in Multi-Dimensional HPLC

Method Development on Next Generation RPLC Supports

An Overview of the the Development of Stationary Phases for Reversed-Phase Liquid Chromatography

HPLC at High Temperature and High ph with a New, Highly Stable Silica Column

Separation of Barbiturates

Carbonaceous RPLC Stationary Phases Based on Porous Zirconia STABILITY is the Name and SELECTIVITY is the Game Paul T. Jackson

Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Reversed Phase Solvents

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Xiqin Yang, Jun Dai, Peter W. Carr* Chemistry Department University of Minnesota

High Temperature Ultra Fast Liquid Chromatography. Peter W. Carr, Jon Thompson, Dwight Stoll, and Adam Schallinger

Isomer Separation on ZirChrom -CARB

Oligonucleotide Separation on ZirChrom -SAX

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

HPLC Column Product Guide

Multi-mode Separations Using Zirconiabased Stationary Phases

A C18 Silica Column With Exceptional Temperature and ph Stability

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Packings for HPLC. Packings for HPLC

Analytical Advantages of Highly Stable Stationary Phases for Reversed-Phase LC

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Reversed-Phase Method Development Guide

LC and LC/MS Column Selection Flow Chart

New Applications of Zirconia Based Stationary Phases

Choosing Columns and Conditions for the Best Peak Shape

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Inertsil ODS-EP Technical Information

HPLC Method Development: Standard Practices and New Columns

Too Polar for Reversed Phase What Do You Do?

HPLC Method Development: Standard Practices and New Columns. Agilent Technologies February 2007

Overview Applications of NUCLEODUR HPLC Phases

Improving HPLC Column Selection and System Performance

Method Development Kits

N_HW1 N_HW1. 1. What is the purpose of the H 2 O in this sequence?

HPLC Column Product guide

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

High Speed 2D-HPLC Through the Use of Ultra-Fast High Temperature HPLC as the Second Dimension

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

ZirChrom Columns and the Metalox 200-C High Temperature Liquid Chromatography Column Heater - The Future of HPLC has Arrived.

ZirChrom Newsletter Vol. #10 Sachtopore-NP and Sachtopore-RP, titania-based HPLC phases

1. What is the major organic product obtained from the following sequence of reactions?

KromasilSFC. Designed for green technology. Introducing Kromasil SFC XT

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

HPLC Column Product Guide

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Validated HPLC Methods

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

Hypersil BDS Columns TG 01-05

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Changing the way you think about HPLC

William E. Barber, Ph.D. Applications Chemist October

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

BETASIL Columns TG Å high purity silica

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

CHAPTER PRACTICE PROBLEMS CHEMISTRY

LIQUID CHROMATOGRAPHY

1. CONCEPTS IN ORGANIC CHEMISTRY 2. SYNTHETIC ORGANIC CHEMISTRY 3. ISOMERISM II 4. HYDROCARBONS II 5. HALOALKANES. Vikasana - CET 2012

1. CONCEPTS IN ORGANIC CHEMISTRY 2. SYNTHETIC ORGANIC CHEMISTRY 3. ISOMERISM II 4. HYDROCARBONS II 5. HALOALKANES. Vikasana - CET 2012

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Benzenes & Aromatic Compounds

Advantages of polymerbased. an alternative for ODS

Fast Screening Methods for Analgesics and Non-Steroidal Anti-Inflammatory Drugs by HPLC

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

High Resolution Fast LC

ChromegaChiral TM CSP Media and Columns

BRCC CHM 102 Class Notes Chapter 13 Page 1 of 6

H P L C C O L U M N S

The Evolving HPLC Column Packings

Method Development for Chiral LC/MS/MS Analysis of Acidic Stereoisomeric Pharmaceutical Compounds with Polysaccharide-based Stationary Phases

Separation of Structurally Similar Steroids on HALO C18 and PFP

Indian School Muscat. Chemistry IIT - JEE

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Method Development with ZirChrom's Ion Exchange Phases

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

for Acclaim Trinity TM P1

New Product Update. HPLC Columns

Setting the Standard for ph Method Development

Next Generation of Phenyl Columns. Chromatography Products.

Handling Products. Sumitomo Chemical Co., Ltd. SUMICHIRAL ~192

Shodex TM ODP2 HP series columns

UPLC Method Development and Validation

The Standard for ph Method Development

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

Optical Isomer Separation Columns and Packing Materials

ChromegaChiral TM CSP Media and Columns

CHEM Chapter 16. Chemistry of Benzene: Electrophilic Aromatic Substitution (homework) W

Comparison Guide to C18 Reversed Phase HPLC Columns

Technical Guide Thermo Scientific Syncronis HPLC Columns

How proteins separate on reverse-phase HPLC

CH 320/328 N Summer II 2018

Transcription:

Synthesis and Use of a New Covalently Bonded C18 Modified Carbon Clad Microporous Zirconia for Fast High Temperature Separations by Peter W. Carr, Clayton V. McNeff, Dwight R. Stoll, Danielle R. Hawker, Angelos Kyrlidis (Cabot), Greg Gaudet (Cabot) 2001 ZirChrom Separations, Inc.

UTLINE Analytical Advantages of Column Stability Development of a New Type of RP Column: DiamondBond-C18 Selectivity Comparison of DiamondBond-C18 with Luna C18 (2) Silica and ther Columns Applications Conclusions

Analytical Advantages of Column Stability Extraordinary Chemical Stability ph Stability Thermal Stability ph < 1 ph > 13 Lower Pressure Drop Less rganic Solvent Thermally ptimize Selectivity Cleaning with Conc. Acid Ion Supression for Acids Ion Supression for Amines Sanitation/ Depyrogenation Less Wear and Tear Higher Flow Rate: Fast Analysis More Robust Analysis Easier Method Development

Patented Synthesis of Carbon Clad Zirconia Lewis Acid Site Zr Zr Zr Zr Zr Zr H H Bulk Zirconia

A New Class of Stationary Phase Media General approach - Cabot Corporation (Billerica, MA): functionalizing agent X-R-Y X reacts with surface Y = functional group X is typically a diazonium salt NH 2 Y + 2 HX + NaN 2 = XN N Y + 2 H 2 + NaX + N N + Y Carbon Clad Zirconia Diazonium Salt Modified Carbon Clad Zirconia

Chemical Structure of DiamondBond-C18 DS DiamondBond-C18 CH 3 CH 3 CH 3 CH 3 CH 3 ( ) 16 10 ( ) 10 16 ( ) 10 16 10 10 CH 3 CH 3 CH 3 CH 3 CH 3 CH Si CH CH 3 CH 3 CH Si CH CH 3 H H H C C C C C C C C C C C C C C Zirconia Substrate Silica Substrate

Stability Testing of 8 DiamondBond 7 6 k' 5 4 3 2 1 0 k' Butylbenzene (0.5M Nitric Acid) k' Butylbenzene (1.0M NaH) k' Butylbenzene (200 Degrees Celsius) 0 250 500 750 1000 1250 2000 Column Volumes LC Conditions: Base Stability DiamondBond TM Phase A, 30 x 4.6 mm id; Mobile phase, 50/50 ACN/Water; Flow rate, 1.0 ml/min.; Temperature, 30 o C; Injection volume, 5ul; Detection at 254nm. Acid Stability DiamondBond TM Phase A, 50 x 4.6 mm id; Mobile phase, 50/50 ACN/Water; Flow rate, 1.0 ml/min.; Temperature, 30 o C; Injection volume, 5ul; Detection at 254nm. Temperature Stability DiamondBond TM Phase B, 50 x 4.6 mm id; Mobile phase, 50/50 ACN/Water; Flow rate, 1.0 ml/min.; Temperature, 30 o C; Injection volume, 5ul; Detection at 254nm.

Phase Stability Comparison at High ph* ZirChrom-PBD ph12.0 Gammabond RP-1 ph 12.0 k' Propranolol 9.00 8.00 7.00 6.00 5.00 4.00 3.00 2.00 1.00 Luna C18 (2) ph 10.0 Extend C18 Rapid Res. ph 11.5 Xterra RP18 ph 12.0 DiamondBond-C18 ph 12.5 0.00 0 2000 4000 6000 8000 10000 12000 14000 16000 Column Volumes of Mobile Phase * Column names are the trademarks of their respective manufacturers.

Chromatographic Selectivity Comparison of DiamondBond-C18 to ther Stable RP Phases LC Conditions: Mobile phase, 40/60 Acetonitrile/50mM phosphate at ph 3.2, Flow rate, 1.0 ml/min., Temperature = 30 o C, Detection at 254nm, 5µl Injection volume. (LC-GC, Vol 13, No. 9, September 1995, 720-726.) Columns Tested*: DiamondBond-C18, Luna C18 (2), ZirChrom-PBD, Gammabond RP-1, Xterra RP18, Polymer Labs PLRP-S * Column names are the trademarks of their respective manufacturers.

22 Non-electrolyte Solutes Benzene Toluene Ethylbenzene p-xylene Propylbenzene Butylbenzene Cl Br Cl B romobenzene p-d ichlorobenzene A nisole M ethy lbenzoate N apthalene A cetophenone N 2 CN N 2 N 2 Cl Benzonitrile Nitrobenzene p-nitrotoluene p-nitrobenzyl Chloride Benzophenone Cl H H NH H H H Benzylalcohol 3-Phenyl Propanol N-Benzyl Formamide Phenol p-chlorophenol

Normalized Selectivity Comparison*: DiamondBond-C18 and Luna C18 (2) 1.500 1.000 0.500 0.000-0.500-1.000-1.500 Luna C18 (2) DiamondBond-C18 Log (solute k'/benzene k') benzyl formamide benzyl alcohol phenol 3-phenyl propanol p-chlorophenol acetophenone benzonitrile nitrobenzene methylbenzoate anisole benzene p-chlorotoluene p-nitrobenzyl chloride toluene benzophenone bromobenzene ethylbenzene p-xylene napthalene p-dichlorobenzene propyl benzene butyl benzene Solute * Column names are the trademarks of their respective manufacturers.

Regression Data from log k vs. log k Plots for All Columns versus Luna C18 (2)* Column vs. Luna C18 (2) R 2 ZirChrom-PBD 0.985 Gammabond RP-1 0.981 Xterra RP18 0.972 Polymer Labs PLRP-S 0.963 DiamondBond-C18 0.889 * Column names are the trademarks of their respective manufacturers.

Applications Benzodiazepams - Anti-anxiety Drugs Norm. 600 500 ph = 7.0 3 4 400 300 200 1 2 100 0 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 min LC Conditions: Column, 50 x 4.6 DiamondBond TM -C18; Mobile phase, 20 to 40% THF, 20 min ramp in 50mM potassium phosphate ph 7.0; Flow rate, 1.0 ml/min; Temperature, 30 o C; Injection volume, 2 ul; Detection at 254 nm; Solute concentration 0.25 mg/ml; Solutes, 1=xazepam, 2=Temazepam, 3=Diazepam, 4=Medazepam.

DiamondBond-C18 Selectivity* a) 150 x 4.6 mm DS b) 100 x 4.6 mm DiamondBond-C18 1,2 1 2 Ethylbenzene p-xylene 0 1 2 3 4 5 6 7 8 9 min 0 1 2 3 4 5 6 7 8 9 min LC Conditions: a) Column, 150 x 4.6 Zorbax Eclipse XDB-C8 S/N: USRK010769; Mobile phase, 65/35 ACN/Water; Temperature, 30 o C; Flow rate, 1.0 ml/min.; Injection volume, 5 ul; Detection at 254 nm; Solutes: 1=Ethylbenzene, 2=p-xylene. b) Column, 100 x 4.6 DiamondBond-C18, D082401A; Mobile phase, 37.5/5/57.5 ACN/THF/Water; Temperature, 60 o C; all other conditions the same as a). * Column names are the trademarks of their respective manufacturers.

mau 250 200 150 100 Separation of Anticonvulsants on DiamondBond -C18 and Hypercarb* T 3 1 2 4 (N = 8,700) a) DiamondBond-C18 5 (N = 9,400) 50 0 mau 175 150 125 100 75 50 0 1 2 3 4 5 6 7 3 1 2 b) Hypercarb 5 (N = 4,900) 4 (N = 5,400) min 25 0 0 1 2 3 4 5 6 7 LC Conditions: a) DiamondBond-C18 100 x 4.6; Mobile phase 25/75 THF/50mM Ammonium phosphate, ph 7.0; Flow rate, 1.0 ml/min.; Temperature, 50 o C; Injection volume, 0.5 ul; Detection at 220nm; Solutes: 1=Primidone, 2=Metharbital, 3=Mephenytoin, 4=Phenobarbital, 5=Phenytoin. b) Hypercarb 100 x 4.6; Mobile phase, 31/69 THF/50mM Ammonium phosphate, ph 7.0; all other conditions the same as in a). min * Column names are the trademarks of their respective manufacturers.

pioids mau 160 140 3 ph = 11.0 120 100 80 1 2 4 60 40 20 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 LC Conditions: Column, 100 x 4.6 DiamondBond TM -C18; Mobile phase, 26.5/73.5 THF/20mM Ammonium phosphate, ph 11.0; Flow rate, 1.0 ml/min.; Temperature, 40 o C; Injection volume, 1.0 ul; Detection at 220nm; Solutes: 1=Naloxone, 2=Codeine, 3=Ethylmorphine, 4=xycodone min

Fast Separations Non-Steroidal Anti-Inflammatories mau 80 70 1 ph = 1.75 60 50 2 40 3 4 30 20 10 0 0 1 2 3 4 5 6 min LC Conditions: Column, 100 x 4.6 DiamondBond TM -C18; LC Conditions: Mobile phase, 50/50 ACN/50mM Phosphoric acid, ph 1.75; Flow rate, 1.0 ml/min.; Temperature, 65 o C; Injection volume, 1.0 ul; Detection at 254nm; Solutes: 1=Acetominaphen, 2=Ketoprofen, 3=Ibuprofen, 4=Naproxen

Future Directions Ion-Exchangers Polar Bonded Phases (NPLC) Chiral Stationary Phases (CSPs) Reversed-Phases for Biomolecules Nonporous Preparative

Conclusions DiamondBond TM -C18 is an ultra-durable and efficient carbonbased HPLC stationary phase. DiamondBond TM -C18 is stable at the extremes of ph and at column temperatures as high as 200 o C. DiamondBond TM -C18 had the most different selectivity relative to conventional DS phases for the 22 selected non-ionizable compounds. DiamondBond TM -C18 s durability allows for high and low ph separations for improved peak shape. DiamondBond TM s chemistry is as flexible as silane chemistry and in the future will be used to produce a broad family of novel ultradurable phases.