Importance of in situ Monitoring in MOCVD Process and Future Prospects

Similar documents
Reprinted from February Hydrocarbon

Applications of Laser Spectroscopy to Highly Sensitive Analyses

Molecular Solar Cells

Methodology for Analysis of Metallurgical Processes

Figure 1 Enlargement of Powdered Activated Carbon by microscope.

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Complex Compounds Background of Complex Compound Technology

In-Situ FTIR Spectroscopy and Metrology of a Tungsten CVD Process

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy


Lecture 1: Vapour Growth Techniques

VACUUM TECHNOLOGIES NEEDED FOR 3D DEVICE PROCESSING

Atomization. In Flame Emission

Process Development & Scale-Up of the AIR Technology

Supporting Information

Evolved gas analysis by simultaneous thermogravimetric differential thermal analysis-fourier transformation infrared spectroscopy (TG-DTA-FTIR)

Thermochemistry/Calorimetry. Determination of the enthalpy of vaporization of liquids LEC 02. What you need: What you can learn about

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

White Paper. Overview: NDIR Definition:

FT-IR-iPAS A tool for industrial multicomponent gas measurement Christian Hirschmann 1,2 *, Jussi Tenhunnen 2, Satu Ojala 1,2 and Riitta Keiski 1

FTIR INVESTIGATION OF THE AGEING PROCESS OF CARBON NANOWALLS

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

Introduction to Fourier Transform Infrared Spectroscopy

Measurement Technique and its Application to Trace Components of Atmospheric Gas

1 WHAT IS SPECTROSCOPY?

Introduction to Nanotechnology Chapter 5 Carbon Nanostructures Lecture 1

TABLE OF CONTENT. Chapter 4 Multiple Reaction Systems 61 Parallel Reactions 61 Quantitative Treatment of Product Distribution 63 Series Reactions 65

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

The Effects of Hydrazine Monohydrate Surface Doping on Graphene

k T m 8 B P m k T M T

Methods of pollution control and waste management - laboratory. Adsorptive removal of volatile organic compounds from gases streams

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

PRINCIPLE OF ICP- AES

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

INTERNATIONAL STANDARD

Supplementary Figure S1. Verifying the CH 3 NH 3 PbI 3-x Cl x sensitized TiO 2 coating UV-vis spectrum of the solution obtained by dissolving the

Infra Red Spectroscopy

Biomimetic material - poly(n-vinylimidazole)-zinc complex for CO 2 separation

HYPHENATED TECHNOLOGY GUIDE

Evaluation of the plasmaless gaseous etching process

Burning a Hydrocarbon II

Secondary Ion Mass Spectrometry (SIMS)

Fourier Transform Infrared. Spectrometry

HYPHENATED TECHNOLOGY GUIDE

Industrial In-line and Multi Component Monitor Using Absorption Spectroscopy and Its Application

Thin Film Bi-based Perovskites for High Energy Density Capacitor Applications

Training Coarse ECOPROBE 5 CHEMISTRY RS DYNAMICS

Gas Chromatography. Introduction

Ferroelectric Ceramic Technology for Sensors. Jim McIntosh Ceramic Operations Manager PCB Piezotronics

FEATURE ARTICLE. The CS-100 Series High-precision Chemical Solution Monitor in the Semiconductor Cleaning Process. Takaaki Yada.

Fabrication Technology, Part I

OBSERVATION OF SURFACE DISTRIBUTION OF PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY DURING D 2 GAS PERMEATION THROUGH PD COMPLEXES

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

Modern Methods in Heterogeneous Catalysis Research: Preparation of Model Systems by Physical Methods

CH. 21 Atomic Spectroscopy

Electronic Supplementary Information

Physics 1000 Half Life Lab

Chemie en Technologie van Materialen (Materials Science and Technology)

1901 Application of Spectrophotometry

Transmutation Reaction Induced by Deuterium Permeation Through Nanostructured Multi-layer Thin Film

Rapid Catalyst Screening Reactors

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Development of Deposition and Etching Technologies for Piezoelectric Elements for Ferroelectric MEMS

Case Study of Electronic Materials Packaging with Poor Metal Adhesion and the Process for Performing Root Cause Failure Analysis

NOMENCLATURE FOR CHROMATOGRAPHY NOMENCLATURE FOR SUPERCRITICAL FLUID CHROMATOGRAPHY AND EXTRACTION

Solid State Science and Technology, Vol. 13, No 1 & 2 (2005) ISSN

Chapter 1 Introduction: Matter and Measurement

CHAPTER 6 DIELECTRIC AND CONDUCTIVITY STUDIES OF ZIRCONIUM TIN TITANATE (ZST)

RESULTS AND DISCUSSION Characterization of pure CaO and Zr-TiO 2 /CaO nanocomposite

4023 Synthesis of cyclopentanone-2-carboxylic acid ethyl ester from adipic acid diethyl ester

Supporting Information. High Selectivity of Supported Ru Catalysts in the Selective. CO Methanation - Water Makes the Difference

* Defining Temperature * Temperature is proportional to the kinetic energy of atoms and molecules. * Temperature * Internal energy

Monitoring Emulsion Polymerization by Raman Spectroscopy

Use of Near Infrared Spectroscopy for in- and off-line performance determination of continuous and batch powder mixers: opportunities & challenges

Effects of a static magnetic field on biological samples

Introduction to Fourier Transform Infrared Spectroscopy

ECE 695 Numerical Simulations Lecture 35: Solar Hybrid Energy Conversion Systems. Prof. Peter Bermel April 12, 2017

APPLICATIONS OF RAMAN AND AND BIOSYSTEMS APPLICATION: WESLEY THOMPSON JULY 17 TH, 2008

Effect of Polyacramide as Drilling Fluid in Kuttanadu Soil

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

INTEGRATED VISIBLE LIGHT SENSOR BASED ON THIN FILM FERROELECTRIC MATERIAL Ba 0,25 Sr 0,75 TiO 3 to MICROCONTROLLER ATMega8535

Vacuum System of Synchrotron radiation sources

AlCl3(aq) + 3 NaOH(aq) Al(OH)3(s) + 3 NaCl(aq)

Micro Chemical Vapor Deposition System: Design and Verification

Systems Engineering Spring Group Project #1: Process Flowsheeting Calculations for Acetic Anhydride Plant. Date: 2/25/00 Due: 3/3/00

Spectroscopy tools for PAT applications in the Pharmaceutical Industry

Sub-category: Physics and Principles of Measurement Topic: Monitoring anesthetic gases and vapours Date: January 15-17, 2016 Language: English

Wafer holders. Mo- or Ta- made holders Bonding: In (Ga), or In-free (clamped) Quick and easy transfer

Dynamic Equipment and Process Simulation for Atomic Layer Deposition Technology

Course theme. Three hours of lab Complete E1 (Parts 1, 2, 3, 4, and 5B) Prepare discussion presentation Prepare team report.

Three hours of lab Complete E1 (Parts 1, 2, 3, 4, and 5B) Prepare discussion presentation Prepare team report. Course theme

PHYSICAL AND CHEMICAL PROPERTIES OF ATMOSPHERIC PRESSURE PLASMA POLYMER FILMS

Chemistry Instrumental Analysis Lecture 31. Chem 4631

2 SPECTROSCOPIC ANALYSIS

Particle Size Determinations: Dynamic Light Scattering: page 161 text

MICROCHIP MANUFACTURING by S. Wolf

Chromatography & instrumentation in Organic Chemistry

ATOMIC SPECROSCOPY (AS)

INTRODUCTION TO MEASUREMENTS

Supporting information

Transcription:

G u e s t F o r u m Guest Forum Series of Lectures by Screening Committees of the Second Masao Horiba Awards Importance of in situ Monitoring in MOCVD Process and Future Prospects Hiroshi Funakubo Tokyo Institute of Technology Graduated School of Science and Engineering Associate Professor Ph. D. in Engineering There is growing expectation in hopes of finding new or improved substances with excellent properties through further multiplicate components, in multi-component oxide thin films such as high-temperature superconductors, giant magnetoresistance effect oxides, and ferroelectric oxide. In manufacturing these devices, composition reproducibility that influences properties are important, and MOCVD (Metal Organic Chemical Vapor Deposition) is drawing attention. We will confirm the basic principle of MOCVD such as reaction mechanism in thin fi lm fabrication and the control of compositions, using Pb(Zr,Ti)O 3 (PZT) thin fi lm as an examples. We will also explain the effectiveness of Fourier Transform Infrared Spectroscopy (FTIR) as a tool for extracting the optimum conditions for the industrialization process of MOCVD, using hard data. In addition, we will propose a process in which FTIR is installed as an in situ monitor for online feedback controls in the MOCVD process, with excerpts from experiment results. Finally, future prospects will also be discussed. Introduction Recently, there have been notable developments of multi-component oxide thin films such as hightemperature superconductors (Y-Ba-Cu-O, Bi-Sr- Cu-O), giant magnetoresistance effect oxides (La- Ca-Mn-O), and ferroelectric oxides (Pb-Zr-Ti-O, Sr- Bi-Ta-O) in various fields. MOCVD (Metal Organic Chemical Vapor Deposition) has shown excellent aspects (i.e., high step coverage, a high deposition rate, and composition uniformity in a wide range) as a method of device fabrication for multi-component oxide thin film. Properties of multi-component oxide thin film devices depend largely on the composition, in which optimization of composition and securing reproducibility are important. So far, they have been accomplished by optimizing process conditions through trial-anderror. In the future, in order to develop completely new materials, an increase in the number of elements would become inevitable, and this approach requires tremendous amounts of time and money. Figure 1 shows a deposition model of PZT *1 based on MOCVD. It is important to understand gas phase reaction as the material reaches the substrate, the reaction on the substrate, as well as the material-feeding rate. Development of a system that monitors them in situ, simultaneously, is needed. In this lecture, taking a PZT thin film for example, effectiveness of in situ monitoring in the MOCVD process using FTIR is presented, and future prospects will be discussed. *1: Due to its large residual polarization, lead zirconate titanate thin film is applied to ferroelectric memories, and also to actuators and the like due to its excellent piezoelectric property. Deposition Model - deposition model of PZT by MOCVD - Before reaction chamber (180 C) Gas phase diffusion Gas phase reaction? In reaction chamber (about 510 C) Elimination reaction Gas phase reaction Reaction on substrate Gas phase diffusion Figure 1 Deposition Model - Deposition Model of PZT by MOCVD - 54 English Edition No.11 February 2007

Technical Reports Basic Structure and Conditions Experimental device has an FTIR analyzer installed in the bypass to the reaction chamber as shown in Figure 2. The FTIR analyzer is a commercial FTIR with just a gas cell added. It should be noted that there were doubts concerning whether high S/N analysis data can be obtained (with raw gas temperatures at a high 180 C) along with several unidentified factors such as the measurability at very low concentration levels, the stability of the window material and the lack of actual achievements in multi-component analysis based on FTIR. Table 1 shows the experiment conditions. Table 1 Conditions Materials Pb(C 11 H 19 O 2 ) 2, Zr(O t-c 4 H 9 ) 4, Ti(O i-c 3 H 7 ) 4 FTIR Measuring conditions Gas cell Evaporation Partial pressure of measured gas Deposition rate resolution: 4cm -1, TGS detector, Accumulated number of times: 100 Optical path length: 0.1m, Material: SUS316 Bubbling method (sublimation method) Pb(C 11 H 19 O 2 ) 2 : 0.003-0.100 Torr Zr(O t-c 4 H 9 ) 4 : 0.002-0.056 Torr Ti(O i-c 3 H 7 ) 4 : 0.005-0.119 Torr 2 nm/min 60 minutes detection Equipment Schematics Mass flow controller Oven Preheater Substrate Heater Filter Exhaust Adsorber Mechanical booster pump Rotary pump Material gas Infrared radiation Exhaust IR detector Figure 2 Schematic Diagram of Experiment Equipment Confirming FTIR Effectiveness Spectrum and Linearity Figure 3 shows single gas phase spectrum of each material-gas and the linear relationship between concentration and absorbance with the wave number indicated by arrows. The peak indicated by the arrow in the Zr spectrum represents Zr and O bonding, evidence of Zr existing in the gas that forms a film. Unfortunately, the same could not be observed in Pb and O, but was seen in the bonding of Ti and O. It has been confirmed that measurement is indeed possible by implementing FTIR in the CVD system, with linearity and dynamic range also secured. Usable as densitometer Single gas phase spectrum in low concentration Stretching vibration Stretching vibration Stretching vibration Partial pressure Partial pressure Partial pressure Quantitative determination possible up to transmission factor 99.7 (absorbance approx. 0.002). Linearity between partial pressure and absorbance confirmed. Figure 3 Single Gas Phase Spectrum in Low Concentration and Linearity English Edition No.11 February 2007 55

G u e s t F o r u m Guest Forum Confirming Gas Phase Reaction Importance of in situ Monitoring in MOCVD Process and Future Prospects From the mixed spectrum of Zr(O t-c 4 H 9 ) 4 and Ti(O i-c 3 H 7 ) 4 (Figure 4), it can be seen that the sum of respective single spectra of Zr and Ti differs from the mixed gas spectrum. The difference indicates that gas phase reaction takes place due to mixing of the gases. Further, data was obtained which indicated that with the altering the ratio of the material-gas feed rates of Zr and Ti at mixing, the Zr-material-derived peak and the Ti-material-derived peak shift cleanly and systematically(figure 5). Composition Controllability (Zr+Ti Material System) Mole ratio (thin film) ratio and composition ratio Linear relationship passing through the point of origin (784cm -1 by Zr material) (848cm -1 by Ti material) If FTIR is used as an in situ monitor: Thin film composition can be controlled. Reproducibility of composition is expected. Mixed Spectrum of Zr(O t-c4h9)4 and Ti(O i-c3h7)4 Stretching vibration Stretching vibration Stretching vibration Stretching vibration Deformation vibration Deformation vibration Zr(O t-c 4 H 9 ) 4 Ti(O i-c 3 H 7 ) 4 Mixed gas Sum of single spectra Figure 4 Mixed Spectrum of Zr(O t-c 4 H 9 ) 4 and Ti(O i-c 3 H 7 ) 4 Gas Phase Reaction (Zr+Ti Material System) Low Zr-material feed rate High Ti-material feed rate Stretching vibration Stretching vibration Theoretical feed rate Zr-derived peak to higher wave number Ti-derived peak from low wave number region to position of single gas Figure 5 Gas Phase Reaction (Zr+Ti Material System) Composition Controllability It was confirmed that the ratio of Zr-material-derived spectrum intensity to Ti-material-derived spectrum intensity in Figure 5 has a linear relationship with the composition ratio of the actual thin film with a straight line passing through the point of origin (Figure 6).This fact shows that the use of FTIR as an in situ monitor enables control of thin film composition. In other words, film production without waste batches is possible by checking spectra from FTIR. Figure 6 Composition Controllability (Zr+Ti Material System) Applying FTIR to Solution Vaporization Conventional material feed systems such as the bubbling method are insufficient for mass production due to the limitation of the material vapor pressure. Given this factor, the solution vaporization method, where the material is dissolved in a solvent to be pumped to a vaporizer for forced vaporization, is becoming mainstream. When the material is dissolved in the solvent, concentration of the material in the solution is about 1/1000. This increases a degree of difficulty, since spectrum of the solution becomes the background. The FTIR spectra are stable, and as shown in Figure 7, it was confirmed that subtracting FTIR spectrum of single gas from FTIR spectra of mixed vaporized gas out of lead dipivaloyl-methane (Pb(DPM) 2 ) as Pb-material and tetrahydrofuran (THF) as solution provided the spectrum of the original material. It was also confirmed that the material feed rate has linear relationship with absorbance. Likewise, in the mixed material-gas spectrum of Zr, Ti, and Pb, each mixed gas concentration could also be obtained by subtracting the solution spectrum element. Pb(DPM) 2 Material feed rate Subtract THF spectrum Bubbling Solution Vaporization Material's inherent spectrum is obtained by removing THF spectrum. Linear relationship between material flow and absorbance Usable as densitometer Figure 7 Computing Pb(DPM) 2 Spectrum by Subtracting THF Solution Spectrum 56 English Edition No.11 February 2007

Technical Reports Application to Industrialization Process Application to Process Optimization Vaporization using a vaporizer has instability factors that affect the vaporized gas concentration, such as thermal transformation of materials, generation of particles, and fluctuation of the gas feed rate caused by residues in the vaporizer. The optimum conditions such as temperature and flow should be determined to feed the material at a steady concentration, but key is determining the conditions. At least one month is needed to optimize conditions for a single material. The following shows how this time was shortened dramatically. Optimization of Vaporizer Temperature The vaporizer should operate at the stabilized feed temperature 1) lower than thermal decomposition and 2) higher than the temperature in which residues are formed in the vaporizer. In addition, 3) it is important to ascertain the stability of gas concentration by measuring it at the vaporizer outlet. Measuring these by FTIR allow for quick determination of the optimum vaporizer temperature. 1) Confirming thermal decomposition temperatures of materials When measuring the vaporized gas using FTIR by altering the vaporizer temperature, absorbance of the material element spectrum drops at temperatures over 180 C in the case of Zr(O t-c 4 H 9 ) 4, and at the same time, the spectrum of the decomposed product isobutene is observed. Likewise, in the case of Ti(O i-c 3 H 7 ) 4, the absorbance of the material element spectrum drops at temperatures over 250 C, and at the same time, the spectrum of the decomposed product called propene is observed. 2) Confirming the material's unvaporized temperature The absorbance of Pb(DPM) 2 increases in the vicinity of 100 C and reaches a plateau from around 180 C to 300 C (Figure 8). The data indicates that the optimum condition of the temperature inside the vaporizer is in the range over 200 C and below 300 C where unvaporized products are no longer created. With the conventional method, where all residues are measured by opening the vaporizer after the material is vaporized (e.g., three hours per condition), it will take several days to confirm the optimum temperature of a material. The effectiveness of FTIR is obvious if one considers the high material cost (several hundreds of thousands of yen) and the costs and time for the confirmation. Spectrum change with altering the vaporizer temperature Change in vaporizer temperature and absorption intensity at 1563cm -1 Material designation Carrier Vaporizer temperature Figure 8 Ascertainment of Non-vaporized Substances in the Vaporizer 3) Measurement of gas concentration at the vaporizer outlet Monitoring the concentration at the vaporizer outlet is most important for stabilization of the material feed rate. Figure 9 is a graph showing variation of the Pbmaterial-gas concentration measured by FTIR versus time, where the concentration is instable at 210 C compared to 250 C. The likely cause is the process where the material-gas concentration drops because the solution is first evaporated and the material is condensed at the leading edge of the vaporizer nozzle due to the partial pressure difference between the material and the solution, and the condensed material then vaporized to raise up the concentration. In the previous section, the optimum temperature inside the vaporizer of Pb(DPM) 2 has resulted in the temperature range of 200 C to 300 C, but this is consequent only after stabilization over time. This is an example in which FTIR analysis revealed that the optimization can be attained from the beginning, with the vaporizer set at 250 C. Fluctuation of gas concentration at the vaporizer outlet affected by the vaporizer temperature Concentration instability Concentration instability FTIR measuring time (90 s) Setting Setting Carrier Time It can be judged that the liquid material being fed is immediately vaporized at the setting of the vaporizer temperature of 250 C. Figure 9 Fluctuation of Gas Concentration at the Vaporizer Outlet English Edition No.11 February 2007 57

G u e s t F o r u m Guest Forum Optimization of Deposition Process Importance of in situ Monitoring in MOCVD Process and Future Prospects Figure 10 shows the curves of the film composition rate and the substrate deposition rate versus material feed rate. With an increasing feed of the Pb-material, the deposition speed decreases and in addition, the composition ratio changes even though the feed rate is constant (in the case of Zr and Ti). FTIR measurement revealed that the material-gas concentration of Zr and Ti on the substrate changed to low through the materials' gas phase reaction with each other. Because the material-gas concentration of Zr and Ti observed by FTIR spectrum shows the same trend as the deposition rate does, the deposition rate can be estimated by measuring the FTIR spectrum in front of the reaction chamber. On the other hand, in the case of Pb, it was confirmed that the materialgas concentration observed from the FTIR spectrum increases proportionally with the increasing Pb-material feed rate without having any area where the concentration does not change. For Pb, in the area where the deposition rate does not change, PZT and PbO are deposited on the substrate, but the high deposition temperature reevaporates PbO selectively due to a high vapor pressure. This is the deposition in the area called a process window in which the PZT single film is formed even though Pb is injected excessively. This is not gas phase reaction, but is considered the reaction on the substrate. We found that monitoring the gas phase reaction using FTIR is an effective means to control the composition of PZT. Outline of Experiment System for Feedback Control Process The experiment was conducted, in which the spectrum analysis of the PZT mixed gas in the PZT process was performed using FTIR and the results were fed back online to control the material feed, and thus the required material-gas concentration was obtained. In principle, a liquid mass flow meter is not necessary, since the concentration correction of each material element is calculated from spectrum data of the mixed gas in the FTIR analyzer to control the valve in the mass flow controller of the vaporization feeding equipment through a conversion unit. For example, slight deviation of the material concentration in the solution may occur. The idea is to have the process side deal with such cases, and not return the material to the supplier. As a result of the experiment, concentration variation is suppressed within the rage of 1 to 2 percent by the FTIR feedback control. The superiority to the method without using FTIR was confirmed. The important point is that only one set of FTIR is needed since the mixed gas is monitored for feedback, instead of each single gas of PZT. Through the feedback experiment using the existing MOCVD, a series of procedures for feedback control of the material system could be established and excellent results were obtained in the course of verification of experiment based on the technique. Future tasks are to improve sensitivity of FTIR and, in addition, to set up a feedback system that deals with other simple detecting means such as thermal conduction cells. Film composition ratio Process window With constant feed rates of Zr and Ti, Pb feed rate changes Film composition ratio Deposition rate There is an area where deposition rate does not change. Deposition rate changes, while feed rate does not change. Pb material feed rate Figure 10 Film Composition Ratio and Substrate Deposition Rate versus Material Feed Rate 58 English Edition No.11 February 2007

Technical Reports Conclusion Use of FTIR as an in situ monitor has paved the way for the optimum vaporization conditions and a steady vaporization feed that has been considered difficult to attain via conventional technology, and provides a good prospect for a MOCVD process for PZT thin film fabrication. A use of FTIR demonstrates its strength in the reaction analysis of CVD that has very fast optimization and a difficult deposition mechanism, and to a large extent, is effective at the development phase. In particular, it is considered to help analysis when materials change. Equipment with improved composition controllability using FTIR for gas analysis was developed. Through the Introduction of analytical means alone, we gained considerable knowledge of what was not known, and insight into how to go about implementation. Since in situ analysis of films will become more important, it is imperative that analyzer manufacturers with comprehensive solutions including analyzers other than FTIR become involved in the equipment development for film fabrication of more multiplicated component in the future. Acknowledgements This paper is based on the result of R&D Projects for Immediate-Effect-Type Regional Revitalization Consortium, Regional Consortium of Ministry of Economy, Trade and Industry, 2001. The author acknowledges the contribution of all individuals who collaborated. <Excerpt from the Screening Committee Lecture for Masao Horiba Awards, June 16, 2005 (Publication members have responsibility for the translation)> English Edition No.11 February 2007 59