C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

Similar documents
C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka

MCB NB1-63H Miniature Circuit Breaker

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

90 MCB range Modular circuit breakers for circuit protection

TeSys circuit-breakers

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2..

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

SIRCOVER Manual transfer switches from 125 to 3200 A

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Semiconductor (AC) fuses

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Discrimination of the direct current circuit breakers

X T O B P 1 6 B C 1 S

5SP and 5SY Supplementary Protection UL 1077

General characteristics, Products

Miniature Circuit Breaker

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Redline Unibis : the solution Circuit protection

TEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations

Semiconductor (AC) fuses

BETA Protecting Miniature Circuit Breakers

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

Semiconductor (AC) fuses

TeSys contactors. TeSys D contactors. 690 V on a and c

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

CDB6a. Standard: IEC IEC Trip Curve: B, C and D curves Breaking Capacity: 3000A. Technical data. Rate current

NM1. Moulded Case Circuit Breaker NM1 P-084. Moulded Case Circuit Breakers. 2. Type designation. 1. General. 3. Classification N M 1- /

Miniatur Circuite Breakers (MCB)

3VT4 Molded Case Circuit Breakers up to 1000 A

Cat. No. 140M-F M-D8E-B

CDS. high density spring connection

TEST REPORT IEC :2002 Circuit-Breakers for overcorrect protection for household and similar installation

TeSys enclosed starters 2

Universal limit switches

Masterpact. Installation recommendations

Performance. Standards. Technical data

C60 UL489 차단기. Standard features

Current protection I 2 t long-time protection

GPS1B. Characteristics. Technical performances

TeSys DF IEC-Type Fuseholders

Non-Contact Safety Systems CMS

Installation Contactors ISU-xxx ISM-xxx

Performance. Standards. Technical data

DATA RACK BUSBAR. Data Rack Busbar Systems A.

UL 1077 DIN Rail Supplementary Protectors

Modular contactors for installation into distribution

Semiconductor (AC) fuses

2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P

Electrical installation solutions for buildings Technical details RCDs

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

Contents. Characteristics. Breaking capacity performance levels. Trip Units performance levels. Compact NSX100 to 250 A

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

440V 500V V / / /2 12.

Redline. Line protection by means of MCB s. Protection against overloads. Circuit Protection T1.2

Complementary technical information

Moulded Case Circuit Breakers. Breaking capacity code: S:standard H:Higher type/r:current limiting type

Impedance relay and protection assemblies

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

F F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions

E8EB-N0C2B E8EB-N0B2B

Miniature circuit breakers. Residual current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures

NH fuse-links gg 500VAC double indicator/live tags size 000, 00, 0, 1, 2, 3

Semiconductor (AC) fuses

8 Installation Equipment

A9 R A9 X P H 4 12

Power Distribution System SVS04

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

Power Distribution System SVS04

Test Report issued under the responsibility of: SHA-001 Date of issue... : Total number of pages... : 292. Report Number...

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

1SDC007004D0205. Coordination tables

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Electrical installation solutions for buildings Technical details Arc Fault Detection Devices

PHOENIX CONTACT - 04/2016. Features

K04 TYPE -40 C +85 C 20000H

Technical catalogue SmiSSline electrical protective devices in a system

Air circuit breakers Hw. High powered

Microprocessor Based Characteristics and adjustments

1SDC007004D0201. Discrimination tables

Operating Instructions for Digital Manometer. Model: MAN-SD

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

Transcription:

C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth leakage protection when combined with a Vigi C0 module without temperature de: compliance with standard: EN 009 (refer to pages 905/) # remote tripping, indication, by adding auxiliaries common to the entire C0/C0 range (refer to pages 90/). description Technical data # approval: IMQ # current : 3 to 5 A # voltage Ue max.: 0 V AC # insulation voltage Ui: 500 V # impulse withstand voltage Uimp: kv # compliance with standard EN 09: devices accessible by unexperienced persons # breaking capacity: 5 as in EN 09 voltage breaking cap. (V) Icn,, 3, P 30 00 0000 5 as in IEC 097. (Icu) voltage breaking cap. (V) Icu (ka) P 30 0 30 0 0 00 5 3 (), 3, P 30 0 0 00 5 0 0 () breaking capacity under pole with IT isolated neutral system (case of double fault) # service breaking capacity Ics =75 % Icu # positive break indication # fast closing ensures simultaneous closing of poles # electrical durability: 5 3 A: 0000 cycles (O-C) 5 0 5 A: 5000 cycles (O-C) # limitation class: 3 # mechanical durability: 0000 cycles (O-C) # bistable fixing pawl: simplifies disassembly # weight (g): P P 3P P 05 0 5 0 # connection: 5 flexible cables:.5 to 35 mm 5 rigid cables: to 50 mm 5 terminals ensure: - degree of protection IP - tightening of wide cross-section cables - pull-out withstand of cables - automatic guiding of cable into the correct position # markers: 5 marker clips next to the upstream terminal 5 label holder on handle (P, 3P, P) # degree of pollution: 3 (for use in an industrial environment) # degree of protection: 5 open or surface mounted device: IP 5 in a Pragma or Prisma enclosure: IP (IPxxD) B curve 3 and 5 In # protection of very long cables # protection of networks supplied by generators C curve 5 and 0 In # protection of standard networks D curve 0 and In # protection of circuits that supply high inrush current loads: transformers, motors, etc. 900E.fm/ Updated: 5/07/0

C0N circuit-breakers B curve EN 09/EN 009: 0000 - IEC 097-: 0 ka B curve C0N P 3 30 3 0 3 3 00 3 3 5 33 3 30 P 3 3 0 35 3 00 3 5 37 3 3P 3 3 9 0 39 9 00 350 9 5 35 9 39 P 3 35 7 0 353 00 35 5 355 355 Updated: 5/07/0 900E.fm/3

C0N circuit-breakers C curve EN 09/EN 009: 0000 - IEC 097-: 0 ka C curve C0N P 3 35 3 0 357 3 00 35 3 5 359 3 35 P 3 30 0 3 3 00 3 5 33 30 3P 3 3 9 0 35 9 00 37 9 5 39 9 35 P 3 37 7 0 37 00 37 5 37 377 900E.fm/ Updated: 5/07/0

C0N circuit-breakers D curve EN 09/EN 009: 0000 - IEC 097-: 0 ka D curve C0N P 3 37 3 0 379 3 00 30 3 5 3 3 37 P 3 3 0 33 3 00 3 5 35 35 3P 3 3 9 0 37 9 00 3 9 5 39 9 39 P 3 390 7 0 39 00 39 5 393 393 additional information auxiliaries: page 9/ accessories: page 9903/ Vigi module: page 905/ discrimination table: page 95/ dimensions: page 90/ de: page 955/ tripping curves: page 900/ Updated: 5/07/0 900E.fm/5

services practical advice C0 circuit-breaker choice tables C0N C0H current 3 5 0 5 maximum voltage Ue (V) AC 0 DC 5 V/pole minimum voltage Ue min (V AC-DC) insulation voltage Ui (V) 500 impulse voltage Uimp (kv) of poles 3 3 breaking capacity AC EN 09 (ka) Icn 30/00 V 0 0 5 5 Ics 7.5 7.5 IEC 097. (ka) Icu 30 V 0 30 30 0 V 0 0 5 30 00 5 V 3 () 0.5 () 5 0 V 0 Ics 75 % Icu 50 % Icu breaking capacity DC IEC 097- Icu / V (P) 0 5 (ka) () 5 V (P) 0 5 50 V (P) 0 5 fast closing b b b b isolation with positive break indication b b b b adaptable Vigi module b b auxiliaries OF-SD, OF+SD/OF b b b b MN, MX-OF b b b b Tm b b b b connection screwdriver Ø (mm).5 mm maximum blade (POSIDRIV No. ) tightening torque(n.m) 3.5 inlet dimension (mm) H x L: 0 x 0 utilisation temperature ( C) -30 to + 0 storage temperature ( C) -0 to + 70 insulating material self-extinguishing 90 C () -pole breaking capacity in the unearthed neutral IT system (double fault) () the of poles participating in breaking is given between brackets C0N C0H thermal magnetic trip units not interchangeable and not adjustable magnetic Im curve B C D B C D thermal In 0 b b b setting current at 30 C b b b 0 b b b 5 b b b 3 b b b 0 b b b 50 b b b 3 b b b b b b 0 b b b b b b 00 b b b b b b 5 b b b b b b additional information 903E_Ver..fm/ Updated: //0