RST INSTRUMENTS LTD.

Similar documents
Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

E Service E-Series Padlock seires PadlockManual No. Part No. Part No. Part

product manual H-4204 Proving Ring Penetrometer

product manual H-3220A Benkelman Beam

Ballistic pendulum Operating Instructions Fig. 1: Ballistic pendulum SAFETY PRECAUTIONS

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

Squaring HD/HDS machine.

DRIFTER PLOW-IN-A-BOX

Wenzhou Tripod Instrument Manufacturing Co., Ltd.

Lab 8: Centripetal Acceleration

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

THE VIPER ATV PLOW SYSTEM

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

MODEL H3022 MAGNETIC BASE / DIAL INDICATOR / CALIPER COMBO OWNER'S MANUAL

8500 Series MP Safe Locks Models 8550 (Group 1) and 8560 (Group 1R)

Sensor Accessories. Rotary Motion Accessory Pack. Pendulum Rod with two masses, Angular Momentum disc set and Linear Rack with mini c-clamp

HEAVY DUTY SWING-OUT VALVE

To successfully square an HD series machine, you will need the following tools:

INSTALLING TRAK SPORT TIRE CHAINS ON 20 MODEL 3 TIRES

DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL

HEAVY DUTY SWING-OUT VALVE

Electron Microscopy Sciences INSTRUCTION MANUAL. Stereo Microscopes Non-illuminated Stands

For Customer Service, Rev A - 6/ OF 6

THE LOSMANDY G-11 MOUNT

Kirncroft Security Doors

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs

BULOVA MODELS. Selfwinding and. Watches. Specifications 12EBA 12 EBAD 12 ECAD 12 EBACD 12 ECACD. . i -... ~.~.. '. Movement: Self-winding mechanism

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

M-3: Statics & M-10 Elasticity

Double-foliot Japanese Clock

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

Barograph 1.080x

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

Electronic Indicators / Dial Gauges / Dial Test Indicators (Lever-Type)

Must Read Before Installation TadPoleTM Safety and Warnings

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400

/2" Heavy Duty Swing-Out

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA MODELS: 450S AND 450ES

SK Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

Instruction Manual. Kite-22 Camera Crane Starter Package (KITE-22-STARTER) Exclusive of Weights

OPERATING INSTRUCTIONS

Lever-type Dial Test Indicators

SHARK Snow Plow. 52 (132 cm) / 60 (152 cm) Complete system blade INSTRUCTIONS / ESTABLISHMENT

Newton s Second Law Knex cars. Vanderbilt Student Volunteers for Science VINSE/VSVS Rural Training Presentation

Service Information Letter SIL # 017

Miniball Flexible Frame

COMBAT COMMAND AUTOMATIC CHRONOGRAPH

Important Instructions

DISCONTINUED PRECISION MEASURING FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS

Coma Correction. Diagram. Introduction

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

COMPLETE ROTATIONAL SYSTEM

PARTS LIST / TECHNICAL GUIDE

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Measurement of basic constants: length, weight and time

LEAPERS, INC. RED/GREEN DOTS

VELA Tango 100. VELA Tango 100A. VELA Tango 200 GAS

Lever-type Dial Test Indicators

Read the following BEFORE getting started:

Snow Blade Operator s/assembly Instructions

INSTALLATION INSTRUCTIONS PLOW MOUNT KIT Part Number: Application: Honda Foreman 500

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

Issue date: 30. Apr TECHNICAL GUIDE PARTS CATALOGUE. Cal.NH25/26 AUTOMATIC MECHANICAL. SII Products

PRIMARY ARMS 3X COMPACT SCOPE WITH PATENTED.223/5.56, 5.45X39,.308 ACSS RETICLE

Dual Red or Green Electronic Dot Sight Instruction Manual

EXPERIMENTAL INVESTIGATION OF PRECESSION AND NUTATION OF A GYROSCOPE AND DETERMINATION OF MOMENT OF INERTIA

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

Activity P24: Conservation of Linear and Angular Momentum (Photogate/Pulley System)

7.6 Journal Bearings

Circular Motion and Centripetal Force

'-. MICROMEr II. The MICROMET8 II is shipped assembled except for the Filar Eyepiece, Micrometer Stage, and Standard Vise.

PUSH TUBE STANDARD DUTY

u s e r m a n u a l w w w. v e l a. E U

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

The force on a straight current-carrying conductor in a magnetic field is given by,

x Builders Level Service Manual

ER2 Short-head Electric Chain Hoist

IF YOU NEED ANY FURTHER HELP WITH YOUR GALILEO TELESCOPE PLEASE CALL MON-FRI 9AM - 5PM E.S.COM


Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

2 - Machining Fundamentals Measurement. Manufacturing Processes - 2, IE-352 Ahmed M El-Sherbeeny, PhD Spring-2015

ATV WP2 FRONT MOUNT PUSH TUBE

Peltier Application Note

Hey, that wasn t so hard. INSTRUCTION MANUAL AND WARRANTY

WEATHER STATION FIELD GUIDE

GRAVITATIONAL TORSION BALANCE

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT

22X Builder s Level Model No Instruction Manual

Centripetal Force Lab

PARTS CATALOGUE / TECHNICAL GUIDE Cal. 4F32A, 8F32A Cal. 8F33A, 8F35A

INSTRUCTIONS FOR ATTACHING THE NORDIC PLOW TO THE ACTION TRACKCHAIR

4-14X44 FRONT FOCAL PLANE SCOPE WITH ARC-2 MOA RETICLE

QUAKE BRAKE TM MODEL QBC-12 SEISMIC SWAY BRACING KIT FEATURING

Technical Guide TG-19-C-001-E D. Produced by: rendav Date: Modifications: See last page CALIBRE 2500

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

Installation Manual For Habu 32 Struts F4 Struts Habu 2 Struts

BATTERY REPLACEMENT MANUAL FOR CAL. 4F (LADIES ) / 8F (GENT S) SERIES WATCHES

Dial Test Indicators SERIES 513

Transcription:

RST INSTRUMENTS LTD. RST Tape Extensometer Instruction Manual Copyright Ltd. All Rights Reserved. Ltd. Kingston St., Maple Ridge, B.C. Canada VX Z Tel: () - Fax: () - Email: info@rstinstruments.com Website: www.rstinstruments.com

i RST Tape Extensometer Instruction Manual Although all efforts have been made to ensure the accuracy and completeness of the information contained in this document, R.S.T. Instruments Inc. reserves the right to change the information at any time and assumes no liability for its accuracy. Product: RST Tape Extensometer Instruction Manual Document number: EXMH Tape Extensometer Instruction Manual.doc Revision:. Revision Date: July,

ii TABLE OF CONTENTS INTRODUCTION... INSTRUCTIONS FOR USE... TEMPERATURE COMPENSATION... APPENDIX A... TESTING THE TENSIONING SPRING... APPENDIX B... USING THE CALIBRATION FRAME... APPENDIX C REPLACING THE TAPE... TABLE OF FIGURES Figure. Tape Extensometer Front View... Figure. Tape Extensometer Side View... Figure. Aligning Centre Mark... Figure. Correct Tension Alignment... Figure. Imperial Dial Indicator Face... Figure. Metric Dial Indicator Face... Figure. Setup for Testing the Tape Extensometer... Figure. Using the Calibration Frame...

RST Tape Extensometer Instruction Manual INTRODUCTION The tape extensometer is comprised of an epoxy coated aluminum body, adjustment collar and a quality shockproof jeweled bearing dial indicator. The chrome-clad tape with black markings bonded to the steel is recessed beneath multiple layers of nickel and chrome that is electroplated to provide greater resistance to wear and corrosion. FIXED END SHACKLE DIAL INDICATOR END SHACKLE TAPE KNURLED ADJUSTMENT SLEEVE TAPE WHITE MARKS Figure. Tape Extensometer Front View Tape Reel Figure. Tape Extensometer Side View

RST Tape Extensometer Instruction Manual INSTRUCTIONS FOR USE. Unscrew the knurled adjustment sleeve on the extensometer until the dial indicator reads zero.. Clip the shackle that is attached to the end of the punched tape onto the eyebolt in the reference surface (rock face or tunnel wall etc.).. Pull back the extensometer, allowing the punched tape to unwind, until you can clip the shackle on the body of the extensometer onto the opposite eyebolt.. Take the slack out of the tape by winding it on the reel and then loosen it slightly until the nearest punched hole will just engage with the pin at the tip of the extensometer.. Push the tape onto the pin and secure the tape into place using the swiveling latch.. Turn the knurled adjustment sleeve on the extensometer to take up the tension on the tape until the white reference marks are accurately aligned (see Figure ). Accuracy of alignment affects the reading accuracy. X INCORRECT - NOT ALIGNED ALIGNED CORRECTLY Figure. Aligning Centre Mark. The extensometer, if not supported, will cause the tape to sag and therefore must be supported by the operator. It is important that the axis of the body of the extensometer is in line with the eyebolts in the walls. This is easily checked by swaying the extensometer from side to side and up or down while at the same time observing the alignment of the white marks; from the aligned position the center mark will only move away from the extensometer and never toward it. If the center mark moves toward the extensometer more tension must be applied by tightening the knurled adjustment sleeve (see Figure ).

RST Tape Extensometer Instruction Manual INITIAL POSITION - MARKS ARE ALIGNED X INCORRECT - REMEDY - The center mark moves toward the dial indicator when the extensometer is swayed side to side or up and down. Apply more tension via the knurled adjustment sleeve. Figure. Correct Tension Alignment CORRECT - The center mark will only move away from the dial indicator when the extensometer is swayed. The tension is now set correctly to take a reading.

RST Tape Extensometer Instruction Manual. Once the tension has been set correctly, as explained in step, hold the extensometer such that the marks are aligned. Take a position reading by subtracting the reading of the dial indicator from the measurement of the tape at the point where it engages the punched hole. Example: Tape reads mm Dial indicator reads.mm Field Data Reading = mm -.mm =.mm The imperial and metric dial indicators currently used are shown in Figure and Figure. For information on the previous dial indicators, which have serial numbers below TE (i.e. TE), please contact RST Instruments for the previous version of this manual. Figure. Imperial Dial Indicator Face

Figure. Metric Dial Indicator Face Note: IMPERIAL: METRIC: The long sweep hand of the dial indicator reads in. inch and the short sweep hand reads in. inch graduations. (Total range of indicator is. inch) Notice that the imperial dials have large numbers increasing in the clockwise direction (from to ), and small numbers increasing in the counterclockwise direction. Generally, only use the large numbers. Also, notice that on the small dial the whole number is omitted. Thus, both. and. are indicated by. only. Thus, the must be added when the small needle is between and. The long sweep hand of the dial indicator reads in.mm and the short sweep hand reads in mm graduations. (Total range of dial indicator is.mm) Note: The hole spacing on the tape is mm (metric) and inches (imperial). If the dial gauge is approaching the end of its range on a set of readings, it is recommended that the tape extensometer be read with the pin in one hole of the tape and then again with the pin in the next hole in the tape (keeping the same setup). This will allow measurements of movements of any magnitude to be made without a break in the dataset.

How To Read The Dial Gauge (mm range) Dial A: Outside Dial The outside, large dial reads mm with each full revolution and is graduated into labeled main segments. Each of the main segments on the outside dial is equal to.mm ( segments x.mm = mm). For example: An indication of on the outside dial is equal to.mm. Dial B: Top Inner Dial The small inner dial in the face reads mm with each full revolution of its dial and it is graduated in labeled main segments. Each of the labeled segments is equal to mm and the hash marks between each labeled segments indicates mm. As the outside large dial travels one full revolution, the small inner dial in the face will move one hash mark indicating mm. For example: An indication of on the small center dial is equal to mm measured ( revolutions on the outer dial x mm = mm). Sample Reading (example): Measurement = Large Outer Dial + Small Inner Dial Small Inner Dial Indicates between and (indicates mm) Large Outer Dial - Indicates (indicates.mm) Reading is mm+.mm =.mm Therefore the gauge in the diagram is measuring.mm Note: revolution of the Outside Dial = a single mm segment of the Small Inner Dial The reading of the imperial dial gauge is analogous except that the units of measurement are different.

Temperature Compensation The Steel Tape has a Temperature Compensation Coefficient of.x - units/ C, or.x - units/ F @ F or C respectively. Thus a tape that is extended m @ F would be compensated +.x - m = [.x - units/ F x (- F) x m]. Compensation = Coefficient x Δ in Temp. x Distance Tape is Extended

Appendix A Testing the Tensioning Spring. Clip the shackle that is attached to the end of the punched tape onto an overhanging eyebolt.. Secure the tape onto the pin using the swiveling latch.. Attach a. KG/ LB weight onto the other end of the tape extensometer.. Make sure the Center Marking is aligned correctly (Figure and Figure ). Figure. Setup for Testing the Tape Extensometer

Using the Calibration Frame APPENDIX B. Clip the shackle that is attached to the end of the punched tape onto the top eyebolt.. Secure the tape onto the pin using the swiveling latch.. Clip the other shackle onto the bottom eyebolt.. Turn the knurl adjustment sleeve until the reference mark lines up and take note of the reading on the dial indicator. When the tape extensometer is used next, another reading should be taken and compared to the previous reading. This will insure that the extensometer is within acceptable repeatability margins. Figure. Using the Calibration Frame

APPENDIX C Replacing the Tape. Prevent the reel from turning and then turn the handle counterclockwise, to remove it.. Orient the spring washer as shown in the diagram below, so that the washer does not slip off while inserting the reel onto the frame.. Insert the reel onto the frame. Pull out the reel.. Turning clockwise, thread the handle on to the reel.. Continue to turn clockwise to wind the tape on to the reel.. Remove the old tape from the reel.. Slide the new tape clip on to reel.. Push spring washer on to the grooved side of the reel.