Fukushima Daiichi Nuclear Power Station Unit 2 Primary Containment Vessel Internal Investigation

Similar documents
FP release behavior at Unit-2 estimated from CAMS readings on March 14 th and 15 th

TEPCO s Activities on the Investigation into Unsolved Issues in the Fukushima Daiichi NPS Accident

Detection of Xe135 at Nuclear Reactor of Unit 2, Fukushima Daiichi Nuclear Power Station. November 4, 2011 Tokyo Electric Power Company

Miniball Flexible Frame

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

Employees Contractors

Cat. Multi-Processors. Hydraulic Excavators. Multi-Processor/Hydraulic Excavator Compatibility. Features: Maximum Productivity.

Correlation between neutrons detected outside the reactor building and fuel melting

Employees Contractors

product manual H-3220A Benkelman Beam

x Builders Level Service Manual

October 2017 November Employees Contractors

A PRELIMINARY ALIGNMENT PLAN FOR RIA AT MSU

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Galileo Telescope Solar Viewer Joseph Hora, Elizabeth Hora 2017/09/18

1. What would be the dose rate of two curies of 60Co with combined energies of 2500 kev given off 100% of the time?

Vibration-Free Pulse Tube Cryocooler System for Gravitational Wave Detectors I

McQuay Climate Control Singer

Special edition paper

Characterization of Large Structures & Components

OPERATIONS SUPPLEMENT FOR THE COMPARISON AUTOCOLLIMATOR, D600

The Secret Behind the Nobeyama 45-m Radio Telescope s Excellent

STUD & TRACK ROLL FORMING MACHINE

Analysis for Progression of Accident at Fukushima Dai-ichi Nuclear Power Station with THALES2 code

The Dynamical Loading of the WWER440/V213 Reactor Pressure Vessel Internals during LOCA Accident in Hot and Cold Leg of the Primary Circuit

CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

Instructions for Parts Books

Instruction Manual. Kite-22 Camera Crane Starter Package (KITE-22-STARTER) Exclusive of Weights

LUDLUM MODEL 42-5 NEUTRON BALL CART. August 2015 Serial Number PR and Succeeding Serial Numbers

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

ALIGNMENT OF THE MSGC BARREL SUPPORT STRUCTURE

SUB-CHAPTER D.1. SUMMARY DESCRIPTION

RYOBI 10 in. TABLE SAW MODEL NUMBER BTS21

LOW PROFILE TRANSFERS

Neutronics calculations for the ITER Collective Thomson Scattering Diagnostics

Reliability and Traceability in Radiation Calibration

THE LOSMANDY G-11 MOUNT

OASIS WIRELESS WEATHER STATION

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800

ERMSAR Results and Progress of Fundamental Research on FP Chemistry. Japan Atomic Energy Agency. May16-18, 2017 Warsaw, Poland

Installation Manual For Habu 32 Struts F4 Struts Habu 2 Struts

HIMARC Simulations Divergent Thinking, Convergent Engineering

G-FIRE FLANGE ADAPTERS

Visit any one of our 30 locations or visit us on line at

DEVELOPMENT OF HIGH RESOLUTION X-RAY CT TECHNIQUE FOR IRRADIATED FUEL ASSEMBLY

Gas Manifold Installation

Coflore Agitated Cell Reactor

THREE HOLE SPLICE CLEVIS FOR B52 Standard finishes: ZN, GRN Wt./C 126 Lbs. (57.1 kg)

Lectures on Applied Reactor Technology and Nuclear Power Safety. Lecture No 6

Figure 1 Enlargement of Powdered Activated Carbon by microscope.

Simulation of process of hot pilgrim rolling

TEST METHOD FOR DETERMINING BREAKAWAY FORCE OF A MAGNET

ITTC Recommended Procedures and Guidelines

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

MEASUREMENT OF SPENT FUEL ASSEMBLIES IN SPRR-300

Visual Physics 218 Forces & Acceleration [Lab 3]

10 - Celestron Telescope II: Operation

2 Navier-Stokes Equations

Rotary Drilling Rotary Drilling Bits

London Examinations IGCSE

DEVELOPMENT OF MEASURING SYSTEM FOR STRESS BY MEANS OF IMAGE PLATE FOR LABORATORY X-RAY EXPERIMENT

NATURAL CONVECTION HEAT TRANSFER CHARACTERISTICS OF KUR FUEL ASSEMBLY DURING LOSS OF COOLANT ACCIDENT

PREX Background Simulation Update

CBRD30CP3 & BOWRD30CP INSTRUCTION MANUAL

October 30-31, 2014 Paris

Three-dimensional RAMA Fluence Methodology Benchmarking. TransWare Enterprises Inc., 5450 Thornwood Dr., Suite M, San Jose, CA

GP-B Telescope Determine Metering Tube Length P0364 Rev -

HEAVY DUTY SWING-OUT VALVE

Neutronics calculations for the ITER Collective Thomson Scattering Diagnostics

VVER-1000 Reflooding Scenario Simulation with MELCOR Code in Comparison with MELCOR Simulation

Task 3 Desired Stakeholder Outcomes

Instructional Objectives

Grounding and Shielding

PRELIMINARY CONCEPT OF A ZERO POWER NUCLEAR REACTOR CORE

Fatigue Crack Analysis on the Bracket of Sanding Nozzle of CRH5 EMU Bogie

«CALCULATION OF ISOTOPE BURN-UP AND CHANGE IN EFFICIENCY OF ABSORBING ELEMENTS OF WWER-1000 CONTROL AND PROTECTION SYSTEM DURING BURN-UP».

Technical description of photoelectron spectrometer Escalab 250Xi

XL-550. Liste de pièces Lista de Piezas Parts List

HEAVY DUTY SWING-OUT VALVE

NEW COMPLEX OF MODERATORS FOR CONDENSED MATTER RESEARCH AT THE IBR-2M REACTOR *

EDDY CURRENT TESTING

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs

BOLT SIZE Rec.Torque Ft/Lbs. Max Torque Ft/Lbs

3D Drawing - CARIF 260 BSA

In-Vessel Retention Analysis for Pressurised Heavy Water Reactors (PHWR) under Severe Core Damage Accident (SCDA)

EVALUATION OF PWR AND BWR CALCULATIONAL BENCHMARKS FROM NUREG/CR-6115 USING THE TRANSFX NUCLEAR ANALYSIS SOFTWARE

Portable Friction Meter HEIDON Tribo Gear μs Type 94i-Ⅱ. Operating Manual

Static stiffness measurements and the alignment of the Big Wheel prototype

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

ENGINEERING OF NUCLEAR REACTORS. Fall December 17, 2002 OPEN BOOK FINAL EXAM 3 HOURS

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

XL-580. Liste de pièces Lista de Piezas Parts List Copyright SVP Worldwide - All rights reserved

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

nufacturing Company, L.P San Felipe, Suite

INSTALLATION INSTRUCTIONS PLOW MOUNT KIT Part Number: Application: Honda Foreman 500

/2" Heavy Duty Swing-Out

State of Shimane Nuclear Power Station

Altazimuth Mount. Altazimuth Mount

ELECTROMAGNETIC-ACOUSTIC TRANSDUCERS FOR IN-SERVICE MANUAL TESTING OF HEATED OBJECTS

Study of Rupture Directivity in a Foam Rubber Physical Model

Transcription:

Fukushima Daiichi Nuclear Power Station Unit 2 Primary Containment Vessel Internal Investigation April 26, 2018 Tokyo Electric Power Company Holdings, Inc.

1. Primary containment vessel internal investigation overview Investigation Overview : The investigation focused on the area beneath the platform where fuel debris might be present. (January 2018) Scope of this investigation Fallen grating 1 Control rod drive mechanism (CRD) replacement rails Primary Containment Vessel(PCV) Pedestal Pedestal opening RPV Fallen grating 2(No hole) Control rod drive mechanism (CRD) housing Platform Approx. 7.2m Containment vessel penetration used for this investigation (X-6 penetration) Scope of PCV internal investigation implemented this time Subfloor Worker access opening 1

2. Scope of access of survey unit Pedestal opening Survey unit Telescopic survey device Piece of fallen grating 2 Piece of fallen grating 1 (Seen during January (Seen during January 2017 investigation) 2017 investigation) 2Control rod drive mechanism (CRD) housing 1Platform Control rod drive mechanism (CRD) replacement rails Top of platform Approx. 3.2m Approx. 0.3m Approx.. 2.0m Control rod drive mechanism (CRD) replacer Worker access opening 3Mid-level work platform 4Bottom of pedestal Bottom of pedestal Scope of access of survey unit this time Cable tray 2

3. Investigation results 1Top of Platform Pedestal opening CRD replacer LPRM cable PIP cable Pedestal wall Scope of fallen grating Scope of remaining grating Piece of fallen grating CRD replacer Slot opening TIP guide tube Pedestal wall Platform frame Piece of fallen grating 1 (Seen during January 2017 investigation) No significant damage was seen to the CRD replacer or platform frame, etc., and the conditions of these objects remain unchanged from the last investigation (January 2017). Structures in the foreground of the camera image (TIP guide tube, PIP cable and grating, etc.) were found to be damaged and fallen, which may indicate the path of the fallen fuel debris in consideration of the relatively large amount of adhered substances on top of the platform frame. Piece of fallen grating 2 (Seen during January 2017) investigation) Tilted grating Direction of camera Blind spots in the background of the camera image prevent observation of structure deformation or damage, as well as the conditions of the fallen grating and adhered substances. As with the previous investigation (January 2017) no damage was seen to the inner walls of the pedestal within the scope of the observed area. No image taken for this area Adhered substance (above frame) Piece of fallen grating 2 (Seen during January 2017) Grating Fallen grating 1 cannot be seen in this image LPRM(Local Power Range Monitor) :Measures the level of neutron flux in the reactor TIP (Traversing In-core Probe) :Used to calibrate the LPRM PIP (control rod Position Indicator Probe) :Used to detect the position of the control rods (Reference) Inside Unit 2 pedestal Image source and rendering: International Research Institute for Nuclear Decommissioning(IRID) 3

3. Investigation results 2Around CRD housing (1/2) CRD housing Enlarged In foreground of camera image In foreground of camera image CRD flange Hanger rod Support bar Piece of fallen grating 1 (Seen during January 2017 investigation) Camera direction Area directly above fallen grating 1 In background of camera image (Reference) Unit 5 CRD housing In background of camera image Hanger rod, Support bar :Meant to support the load of the CRD (Control Rod Drive Mechanism) housing if it falls The CRD housing supports directly above the piece of fallen grating 1 shows no significant deformation or damage and remains unchanged since the last investigation (January 2017) Within the scope that was investigated none of the CRD housing supports appear to have fallen. Image source and rendering: International Research Institute for Nuclear Decommissioning(IRID) 4

3. Investigation results 2Around CRD housing (2/2) In foreground of CRD housing Camera direction Enlarged camera image PIP cables and LPRM cables obscured by adhered substance CRD flange Hanger rod PIP cable Support bar In background of camera image (Reference) Inside Unit 5 pedestal Parts of the TIP guide tube, PIP cables and LPRM cables could not CRD housing Bottom of CRD Support bracket LPRM ケーブル cables be observed due to adhered substances. PIP cables The grating directly below the areas where parts of the TIP guide tube, PIP cables and LPRM cables could not be observed was found to have fallen. LPRM(Local Power Range Monitor) :Measures the level of neutron flux in the reactor Pedestal Underground access hole Platform CRD replacer Flat bar Slot opening Image source and rendering: International Research Institute for Nuclear Decommissioning(IRID) 5

3. Investigation results 3Mid-level work platform Grating section D has yet to be surveyed Piece of fallen grating 2 Mid-level work platform Section C Mid-level work platform Section B (Area directly below fallen grating 2) Platform Rotation motor A B C D Mid-level work platform Mid-level work platform Section A Checking fallen pieces of grating Camera direction Adhered substance Mid-level work platform frame Image source and rendering: International Research Institute for Nuclear Decommissioning(IRID) It was confirmed that the grating (Sections A~C) in the foreground of the location where the camera was lowered has fallen. Locations where Section B and C grating has fallen show the same conditions as the platform. No significant deformation or damage was seen to the mid-level work platform frame 6

3. Investigation results 4Bottom of pedestal (1/4) Condition of structures and distribution of deposits Piece of fallen grating 1 (Seen during January 2017 investigation) Worker access opening Adhered substance (Mid-level work platform frame) Slot opening CRD replacer rotating frame Worker access opening Mid-level work platform frame Strut Side of cable tray CRD replacer elevator Area around cable trays that was checked Camera direction Bolt remover No significant deformation or damage was seen to structures such as the CRD replacer rotating frame, mid-level work platform frame, struts, or cable trays, etc. Pebble and clay-like deposits cover the entire bottom of the pedestal. Although the deposits appear to be solidified molten material, it is possible that the temperature of the deposits when this substance started to accumulate on top of the cable tray was not hot enough to cause deformation of the cable trays in consideration of the fact that no deformation of the cable trays (4mm thick stainless steel) could be observed. Cable tray (Reference) During Unit 2 outage This structure was removed from inside the PCV when the reactor was in operation Image source and rendering: International Research Institute for Nuclear Decommissioning(IRID) 7

3. Investigation results 4Bottom of pedestal (2/4) Cooling water injection status Piece of fallen grating 1 (Seen during January 2017 investigation) Puddles Puddle CRD replacer elevator Puddle Puddle Deposits above cable tray Cable tray notch Cable tray notch Camera direction Considering that cooling water is pouring in and that the temperature around the bottom of the pedestal is approximately 21 it is assumed that the deposits are being kept cool and stable by the cooling water thatʼs being injected. Puddles were found on the side of the worker access opening and in cable trays through the cable tray notches. Bolt remover Cable tray notch (Reference) During Unit 2 outage This structure was removed from inside the PCV when the reactor was in operation Image source and rendering: International Research Institute for Nuclear Decommissioning(IRID) 8

3. Investigation results 4Bottom of pedestal (3/4) Detailed look at deposit distribution (1) Camera direction Piece of fallen grating 1 (Seen during January 2017 investigation) Resting position of fallen top tie plate(near pedestal inner wall) Resting position of fallen spring-like objects Side of cable tray Worker access opening Puddle Puddle CRD replacer elevator Area where deposits are relatively high (Directly below fallen platform grating 1) Resting place of fallen pipe-like object Resting place of fallen rod-like object (Reference) Unit 5 elevator When looking at the center of the pedestal from the location of the lowered camera the step in elevation that should be present around the cable tray on the left side (approximately 70cm in height) was not clearly defined thereby suggesting that the height of deposits in this area may exceed 70cm at some points. The height of deposits around the CRD replacer elevator appears to be between 40cm to 50cm considering the extent to which the elevator is buried. Furthermore, when looking from the position where the camera was lowered, it was confirmed that the height of the deposits in the area behind the elevator are lower than the cable tray. When viewing the left side of the center of the pedestal from the location where the camera was lowered parts of a fuel assembly (top tie plate) could be seen and fallen objects shaped like rods, pipes, and springs, could be seen in the vicinity. Furthermore, since the height of deposits in this area is higher than that in the surrounding Approx. 50 cm areas, it is possible that the area directly above this location marks one of the paths by which fuel debris fell. Height of deposits in which the CRD replacer elevator is buried Image source and rendering: International Research Institute for Nuclear Decommissioning(IRID) 9

3. Investigation results 4Bottom of pedestal (4/4) Detailed look at deposit distribution (2) Piece of fallen grating 1 (Seen during January 2017 investigation) Camera direction Side of cable tray Area where deposits may be higher than other areas Worker access opening Side of cable tray Cable tray side CRD replacer elevator Resting place of fallen rod-like object Area shown in photo on the right Area where deposits may be higher than other areas Resting place of fallen grating-like object Spots where the height of deposits may be higher than those in the surrounding area were found near the worker access opening. Considering the distribution of these deposits it is possible that there may be multiple locations at which fuel debris fell in addition to the location to the left of the center of the pedestal when looking from the position of the lowered camera. Grate-like fallen objects were found in the vicinity of the location where the height of deposits may be higher than the surrounding area. Rod-shaped falling objects were found near the cable tray. Resting place of fallen rod-like object In regards to the conditions outside the worker access opening, it cannot be confirmed whether or not deposits leaked outside of the pedestal because this area cannot be seen in the images obtained during this investigation. Resting place of fallen grating-like object Image source and rendering: International Research Institute for Nuclear Decommissioning(IRID) 10

3. Investigation results 5Bottom of pedestal (pedestal wall) Pedestal Area not surveyed yet Worker access opening 1 2 Cable tray 1 2 3 4 Position where camera was lowered to 3 4 CRD replacer rotating frame Although the epoxy paint is flaking off and the surface is rough, no significant deformation or damage was found to the inner walls of the pedestal. Image source: International Research Institute for Nuclear Decommissioning(IRID) 11

4. Inscription on top tie plate Part of fuel assembly (top tie plate) Pedestal inner wall Part of fuel assembly (top tie plate) Pebble-like deposits The inscription on the top type plate found at the bottom of the pedestal was examined in order to find out the charging location of the fuel assembly from which it came. Starting from the left the following four letters/numbers could be read: F2XN However, since the serial number, which starts with the fifth letter in this series could not be seen we were unable to identify the charging location of the fuel assembly from which this top tie plate originated. Location of inscription Inscription The inscriptions on fuel assemblies charged into Unit 2 are between five to eight digits long (Plant name (F2)) + (Purchase period (V~AB)) + (Abbreviation for seller (N)) + (serial number (1 )) Image source: International Research Institute for Nuclear Decommissioning(IRID) Image rendering: Tokyo Electric Power Company Holdings, Inc. 12

Supplement 1 Fuel assembly charging position 132 out of the total 548 fuel assemblies that were in the reactor begin with the inscription F2XN and are followed by a serial number. The locations of these fuel assemblies are shown in the diagram below. Concept diagram of fuel assembly location Location where top tie plate was found CRD replacement rails Charing location of fuel assembly marked as F2XN Charging location of fuel support bracket plug There is no F2XN inscription on the fuel support bracket plug 13

5. Conclusion (1/2) <Results of this investigation> Above the platform the structures in the foreground of the image taken with the lowered camera (TIP guide tube, PIP cable, and grating, etc.) have been significantly damaged and/or have fallen, and a relatively large amount of adhered substances were found on top of the frame. On the mid-level work platform grating in the foreground of the images taken with the lowered camera were found to have fallen, much like the conditions above the platform. At the bottom of pedestal no significant deformation was seen to the CRD replacer rotating frame, midlevel work platform frame, struts, or cable tray, etc. Furthermore, considering that cooling water is pouring in and that the temperature around the bottom of the pedestal is approximately 21 it is assumed that the deposits are being kept cool and stable by the cooling water thatʼs being injected. Since the height of the deposits at the bottom of the pedestal is higher on the left side of the center of the pedestal when viewed from the position of the lowered camera, it is possible that the area directly above this location may be one of the paths by which fuel debris fell. At the same time, since deposits on the side of the worker access opening are higher than in the surrounding area it is possible that there are multiple paths by which fuel debris fell. In regards to the conditions outside the worker access opening, it cannot be confirmed whether or not deposits leaked outside of the pedestal because this area cannot be seen in the images obtained during this investigation. 14

5. Conclusion (2/2) < Results of this investigation (cont.)> Although the epoxy paint is flaking off and the surface is rough, no significant deformation or damage was found to the inner walls of the pedestal. The inscription on the top tie plate that was found to have fallen to the bottom of the pedestal could not be read completely thereby preventing the charging location of the fuel assembly from which it originated from being identified. <Measures going forward> Since this investigation yielded information about the conditions at the bottom of the pedestal and the structures that exist between the platform and the bottom of the pedestal, we are deliberating the implementation of another investigation using an armshaped access/survey device that can be reinserted through the X-6 penetration to perform a multipurpose survey in order to ascertain dose rate distributions and a detailed distribution of structures inside the PCV which are necessary in order to deliberate methods for removing the debris. 15

Supplement 2 Condition of structures and adhered substances found inside the pedestal (1/3) Above Platform Area not surveyed yet CRD replacer Pedestal Condition of grating unknown Piece of fallen grating 2 Platform Piece of fallen grating 1 Tilted grating No obstacles above slot opening Conditions above platform :Adhered substance :Location of fallen grating :Location where grating remains :Camera direction 16

Supplement 2 Around the mid-level work platform Condition of structures and adhered substances found inside the pedestal (2/3) Pedestal Cable tray Area not surveyed yet Mid-level work platform Area directly below fallen grating 2 D C Adhered substance B A :Adhered substance :Location of fallen grating :Location where grating remains Mid-level work conditions above platform :Camera direction 17

Supplement 2 Condition of structures and adhered substances found inside the pedestal (3/3) Bottom of pedestal Pedestal :Camera direction Cable tray Area not surveyed yet Worker access opening Deposits above cable tray Area not surveyed yet Worker access opening Location of rodlike fallen object 2 Puddles found Deposits exceed height of cable tray Area where deposits are higher than in other areas Location where cooling water is pouring in Location of spring and rod-like fallen object 1 Location of fallen grate-like object Deposits lower than height of cable tray Location of tie plat and pipe-like fallen object Water surface seen Area where deposits are higher than in other areas CRD replacer rotating frame Puddles and fallen objects found at the bottom of the pedestal Deposits found at the bottom of the pedestal 18

Supplement 3 Equipment for accessing and surveying the PCV through the X-6 penetration We are deliberating the implementation of another investigation using an arm-shaped access/survey device that can be reinserted through the X-6 penetration to perform a multipurpose survey in order to ascertain dose rate distributions and a detailed distribution of structures inside the PCV X-6 Isolation valve Pedestal penetration Pedestal Access/survey device X-6 penetration Access/survey device Moves back and forth Proposal for setting up access/survey equipment in front of the X-6 penetration Axis of rotation Telescopic arm PCV Tilt axis Head rotation axis Arm-shaped access/survey device CRD rails Tilt axis CRD rails Pedestal opening PCV PCV side How access/survey equipment shall be used inside the PCV 19

Reference 1-1: Other observed structures Fallen object above rotation rails <Visible external characteristics> An object resembling the handle of the top tie plate was found to have fallen on top of the platform rotation rails <Estimated dimensions> Using the height of the rotation rails (approximately 7 cm) as reference, the thickness of the object thought to be the handle was estimated to be approximately 1cm which matches the design dimensions of the handle. <Confirmed facts> No identifying characteristics of the handle could be seen Fallen object above platform rotation rails Piece of fallen grating 2 Approx. 7 cm Platform rotation rails Camera direction Platform rotation rails Rotation rail support bracket Fallen object above platform rotation rails Image source: International Research Institute for Nuclear Decommissioning(IRID) 20

Reference 1-2:Other observed structures Pipe-like fallen objects <Visible external characteristics> A pipe-shaped fallen object was found near the location where the top tie plate has fallen at the bottom of the pedestal. A diameter difference can be seen at the end of this object <Estimated dimensions> Using the top tie plate width (approximately 1cm) as reference the width of this pipe was estimated at approximately 2cm. <Confirmed facts> The object could not be identified based upon the visible external characteristics and estimated dimensions Pipe-like fallen objects Diameter difference can be seen at end Resting place of fallen top tie plate Camera direction Top tie plate Enlarged photo Image source: International Research Institute for Nuclear Decommissioning(IRID) 21

Reference 1-3:Other observed structures Spring-like fallen objects <Visible external characteristics> A spring-shaped fallen object was found near the location where the top tie plate has fallen at the bottom of the pedestal. <Estimated dimensions> There were no structures that could be used as reference for estimating the dimensions of this object so the dimensions were not estimated. This spring has a relatively small diameter and more than 15 coils. <Confirmed facts> SRNM detectors, LPRM detector and fuel assemblies all use small diameter springs with more than 15 coils, but it could not be determined from what structure this object originated. Location of spring-like fallen objects SRNM (Startup Range Neutron Monitor): Measures the level of neutron flux in the reactor during startup Resting place of fallen top tie plate Camera direction Enlarged photo Image source: International Research Institute for Nuclear Decommissioning(IRID) 22

Reference 1-4:Other observed structures Rod-like fallen object (around springs) <Visible external characteristics> A rod-like fallen object was found near the spring-like fallen object at the bottom of the pedestal. <Estimated dimensions> There were no structures that could be used as reference for estimating the dimensions of this object so the dimensions were not estimated. <Confirmed facts> The object does not have sufficient dimensions or structural characteristics to aid in identification. Location of rod-like fallen object (around location of fallen spring) Springs Camera direction Rod-like fallen object Image source: International Research Institute for Nuclear Decommissioning(IRID) 23

Reference 1-5:Other observed structures Rod-like fallen object <Visible external characteristics> A Rod-shaped fallen object was found at the bottom of the pedestal. The rod portion of the fallen object appears to have different diameters. <Estimated dimensions> There were no structures that could be used as reference for estimating the dimensions of this object so the dimensions were not estimated. <Confirmed facts> The object does not have sufficient dimensions or structural characteristics to aid in identification. Rod-like fallen object Camera direction Location of rod-like fallen object Image source and rendering: International Research Institute for Nuclear Decommissioning(IRID) 24

Reference 1-6:Other observed structures Grate-like fallen object <Visible external characteristics> Plate-like fallen objects were found near the CRD replacer elevator at the bottom of the pedestal. These fallen objects appear to have grating and are buried in deposits. The objects also appear to be deformed. Enlarged photo <Estimated dimensions> There were no structures that could be used as reference for estimating the dimensions of this object so the dimensions were not estimated. <Assessment results> This object is assumed to be grating based on the visible external characteristics. If it is assumed that this grating fell from directly above then it must be from the mid-level work platform because the grating on the platform still remains. However, the mid-level work platform has only been partially examined so it was impossible to identify the location from which this grating originated. Fallen object Grating-like pattern observable Camera direction Resting place of fallen grate-like object Reference :Platform grating Image source: International Research Institute for Nuclear Decommissioning(IRID) 25

Reference 2:Dose rate and temperature measurements from inside the pedestal Telescopic survey device Piece of fallen grating 1 confirmed during Piece of fallen grating 2 confirmed during January 2017 investigation January 2017 investigation Approx. 0.3m Measurement Point a CRD housing CRD replacer Platform Measurement point Dose rate 1 2 [Gy/h] Temp. 2 [ ] a 7 21.0 b 8 21.0 CRD replacement rails Top of platform Approx. 3.2m Approx. 0.4m Approx. 1.0m Approx. 0.6m Measurement Point b Measurement Point c Measurement Point d c 8 21.0 d 8 21.0 1:Calibrated using Cs-137 radiation source 2:Degree of error: Dosimeter:±7% Temp. gauge: ±0.5 Bottom of pedestal Cable tray tray 26

Reference 3:Overview of fuel assembly parts (top tie plate) Top tie plate (Holds fuel rods together) Fuel rods Water channel Spacer Channel box Bottom tie plate Overview of fuel assembly parts (top tie plate) Fuel assembly diagram 27

Reference 4:Example of equipment that uses springs (SRNM detector) Up Spring (diameter: Approx. 2cm) Used to attach tip of SRNM detector to location of attachment (device attached using elastic force of spring) External view of SRNM detector 28

Reference 5: Images obtained during January 2017 investigation Piece of fallen grating 2 CRD replacer Pedestal wall Location of fallen grating Tilted grating Piece of fallen grating 1 (Position is approximate since it is not visible in the attached photo) Photo not yet rendered in this location Image source and rendering: International Research Institute for Nuclear Decommissioning(IRID) 29

Reference 6:Structures inside the pedestal Platform frame Platform rotation rail CRD rails Rotation rail support bracket Worker access opening 30

Reference 7:Core internals Reactor Pressure Vessel (RPV) Control Rods CR guide tube Pedestal CRD housing 31