Mapping the mechanical stiffness of live cells with the scanning ion conductance microscope

Similar documents
Lecture Note October 1, 2009 Nanostructure characterization techniques

Supporting Information. Three-Dimensional Super-Resolution Imaging of Single Nanoparticle Delivered by Pipettes

SUPPLEMENTARY INFORMATION

Nature Protocols: doi: /nprot Supplementary Figure 1

Appendix (Supplementary Material)

Improving the accuracy of Atomic Force Microscope based nanomechanical measurements. Bede Pittenger Bruker Nano Surfaces, Santa Barbara, CA, USA

AFM Studies of Pristine PCBM Changes Under Light Exposure. Erin Chambers

b imaging by a double tip potential

Mapping Elastic Properties of Heterogeneous Materials in Liquid with Angstrom-Scale Resolution

Supplementary Material

Micro-rheology of cells and soft matter with the NanoTracker

BioAFM spectroscopy for mapping of Young s modulus of living cells

SUPPLEMENTARY NOTES Supplementary Note 1: Fabrication of Scanning Thermal Microscopy Probes

Calculate the total volumes of the following typical microfluidic channel dimensions.

SUPPLEMENTARY INFORMATION

Figure 1.1: Flaccid (a) and swollen (b) red blood cells being drawn into a micropipette. The scale bars represent 5 µm. Figure adapted from [2].

Layer-dependent Anisotropic Frictional Behavior in Two-dimensional

Supplementary Figure 1. AFM scan of DPTAP bilayers. Supplementary Figure 2. Nanopipette geometry used for FEM simulations.

Measuring the spring constant of atomic force microscope cantilevers: thermal fluctuations and other methods

Supplementary Material

NIS: what can it be used for?

Graphene mechanics: II. Atomic stress distribution during indentation until rupture. Supplementary Material

Measuring Young s modulus of 20LP10L20-LLA40 Microspheres and Gelatin-Methacrylamide (GelMA) Hydrogel using nanoindentation

STM: Scanning Tunneling Microscope

Application Note #149 Improving the Accuracy of Nanomechanical Measurements with Force-Curve-Based AFM Techniques

Atomic Force Microscopy imaging and beyond

On the Use of Hot-Film Sensors in the Investigation of Fluid Dynamic Phenomena in the Near-Wall Region

Antifouling performance and mechanism of elastic graphenesilicone

Figure 3: Problem 7. (a) 0.9 m (b) 1.8 m (c) 2.7 m (d) 3.6 m

Dynamics of cell wall elasticity pattern shapes the cell during yeast mating morphogenesis.

Basic Laboratory. Materials Science and Engineering. Atomic Force Microscopy (AFM)

Supplementary Figures

STRESS STRAIN AND DEFORMATION OF SOLIDS, STATES OF STRESS

Lecture: P1_Wk5_L1 Force-Distance Simulations with VEDA

A CONTACT-MECHANICS BASED MODEL FOR DISHING AND EROSION IN

AFM Imaging In Liquids. W. Travis Johnson PhD Agilent Technologies Nanomeasurements Division

Micro-Rheology Measurements with the NanoTracker

Shear stress and shear rates for µ-slides y-shaped based on Computational Fluid Dynamics (CFD)

Mapping of Deformation to Apparent Young s Modulus in Real-Time Deformability Cytometry. Christoph Herold

9 MECHANICAL PROPERTIES OF SOLIDS

Shell Balances in Fluid Mechanics

Point mass approximation. Rigid beam mechanics. spring constant k N effective mass m e. Simple Harmonic Motion.. m e z = - k N z

Effect of AFM Cantilever Geometry on the DPL Nanomachining process

And Manipulation by Scanning Probe Microscope

SUPPLEMENTARY INFORMATION

Chapter 2 Correlation Force Spectroscopy

CENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer

Atomic and molecular interactions. Scanning probe microscopy.

Supplementary Figure 1 shows overall fabrication process and detailed illustrations are given

Instrumentation and Operation

UNIT 1 STRESS STRAIN AND DEFORMATION OF SOLIDS, STATES OF STRESS 1. Define stress. When an external force acts on a body, it undergoes deformation.

Fluid Mechanics II Viscosity and shear stresses

Protrusion Force Microscopy

Linker Dependent Bond Rupture Force Measurements in Single-Molecule Junctions

Mechanics of Materials II. Chapter III. A review of the fundamental formulation of stress, strain, and deflection

Lesson 7: Thermal and Mechanical Element Math Models in Control Systems. 1 lesson7et438a.pptx. After this presentation you will be able to:

Supplementary Information. Synthesis of soft colloids with well controlled softness

Samantha Ramirez, MSE. Stress. The intensity of the internal force acting on a specific plane (area) passing through a point. F 2

BAE 820 Physical Principles of Environmental Systems

Large scale growth and characterization of atomic hexagonal boron. nitride layers

Characterisation Programme Polymer Multi-scale Properties Industrial Advisory Group 22 nd April 2008

Microfluidics 1 Basics, Laminar flow, shear and flow profiles

Revealing bending and force in a soft body through a plant root inspired. approach. Lucia Beccai 1* Piaggio 34, Pontedera (Italy)

Outline Scanning Probe Microscope (SPM)

Supplementary Figure 1: Optical Microscopy. a, Longitudinal cut of a Peripatus solorzanoi. Dotted arrow mark the length L = 13.0 ± 0.

Supplementary Information for. Effect of Ag nanoparticle concentration on the electrical and

Supplementary Figure 1 Extracting process of wetting ridge profiles. a1-4, An extraction example of a ridge profile for E 16 kpa.

Physics 202 Exam 1. May 1, 2013

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

Characterization of MEMS Devices

Supplementary Figure 1 a) Scheme of microfluidic device fabrication by photo and soft lithography,

Lorentz Contact Resonance for viscoelastic measurements of polymer blends

Agilent Technologies. Scanning Microwave Microscopy (SMM)

3.052 Nanomechanics of Materials and Biomaterials Thursday 02/15/07 Prof. C. Ortiz, MIT-DMSE I LECTURE 4: FORCE-DISTANCE CURVES

Experimental Modal Analysis of a Flat Plate Subjected To Vibration

Lorentz Contact Resonance for viscoelastic measurements of polymer blends

Lecture 4 Scanning Probe Microscopy (SPM)

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts. Flow in Pipes and Ducts. Flow in Pipes and Ducts (cont d)

MAAE 2202 A. Come to the PASS workshop with your mock exam complete. During the workshop you can work with other students to review your work.

Simulation of atomic force microscopy operation via three-dimensional finite element modelling

SUPPLEMENTARY INFORMATION

Measurement of the bending of thin inclined nanowires as a method for determining elastic modulus

Supplementary Information. Characterization of nanoscale temperature fields during electromigration of nanowires

AERO 214. Lab II. Measurement of elastic moduli using bending of beams and torsion of bars

Probing the Hydrophobic Interaction between Air Bubbles and Partially. Hydrophobic Surfaces Using Atomic Force Microscopy

Introductory guide to measuring the mechanical properties of nanoobjects/particles

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

3.052 Nanomechanics of Materials and Biomaterials Tuesday 04/03/07 Prof. C. Ortiz, MIT-DMSE I LECTURE 13: MIDTERM #1 SOLUTIONS REVIEW

Supplementary Figure 1 Experimental setup for crystal growth. Schematic drawing of the experimental setup for C 8 -BTBT crystal growth.

DAY 19: Boundary Layer

Scanning Force Microscopy

spreading of drops on soft surfaces

Intensity (a.u.) Intensity (a.u.) Raman Shift (cm -1 ) Oxygen plasma. 6 cm. 9 cm. 1mm. Single-layer graphene sheet. 10mm. 14 cm

3-D Finite Element Analysis of Instrumented Indentation of Transversely Isotropic Materials

Lectures on Applied Reactor Technology and Nuclear Power Safety. Lecture No 6

FEM-SIMULATIONS OF VIBRATIONS AND RESONANCES OF STIFF AFM CANTILEVERS

Pressure drop due to viscosity in a round pipe of radius R is given by the Poiseuille equation: P L. = 8η v R 2

Scanning Force Microscopy: Imaging & Cellular Elasticity

Nanoindentation of Polymers: An Overview

Rapid formation of size-controllable multicellular spheroids. via 3D acoustic tweezers

Transcription:

SUPPLEMENTARY INFORMATION Mapping the mechanical stiffness of live cells with the scanning ion conductance microscope Johannes Rheinlaender and Tilman E. Schäffer Supplementary Figure S1 Supplementary Figure S2 Supplementary Figure S3 Supplementary Figure S4 Supplementary Figure S5 Supplementary Figure S6 Supplementary Figure S7 Supplementary Table S1 Supplementary Note Supplementary Movie S1 Relation between slope and stiffness Statistical variation of the measured slope in IZ-curves Test for mechanical contact Influence of cytochalasin D on cell stiffness Evaluation of the lateral resolution SICM stiffness mapping with different pipette opening diameters Verification of the numerical model Influence of the pipette geometry on A Fluid flow in a conical pipette Time-lapse imaging of a live NIH3T3 fibroblast cell 1

Figure S1: Relation between slope and stiffness s /s 1 1.1.1 α = 3 α = 4 α = 5 Simulations Fit to equation (2).1 1 1 1 StiffnessE /p Figure S1. Relation between the slope of the calculated IZ-curves between 98% and 99% current, s, and the sample stiffness, E, obtained from finite element calculations. Different values of pipette half cone angle α and a constant pipette wall thickness r i /2 were used. Plotting ( s s 1) vs. E p on a double-logarithmic scale shows the calculated data points on lines with a gradient of 1 over several orders of magnitude. This leads to the functional relation expressed by equation (2). The geometrical parameter A was determined by fitting equation (2) and is tabulated in Supplementary Table 1. 2

Figure S2: Statistical variation of the measured slope in IZ-curves A 7 s /I (1 3 m -1 ) B Ion currenti /I 1% Cell 99% Line fits 98% 1 2 Vert. pipette pos.z-z (µm) C Ion currenti /I 1% Substrate 99% Line fits 98% 1 2 Vert. pipette pos.z-z (µm) D 15 σ s /s (%) E Frequency 15 1 5 Gauss fit F 3 σ E /E (%) 4 5 6 7 Slopes /I (1 3 m -1 ) Figure S2. Analysis of the statistical variation of the measured slope in IZ-curves. The measurement of the ion current is influenced by electronic noise, which is mainly Johnson noise of the electrical resistance of the nanopipette 1. The noise of the ion current can therefore be estimated as σ I = 4 kbt f R 4 pa, where k B is the Boltzmann constant, f = 1 khz is the bandwidth of the ion current measurement and R = V / I 1 MΩ is the typical electrical resistance of the pipettes used here. Due to this noise the measured slope of an IZ-curve is also subject to a statistical variation. (A) Measured slope s (normalized with respect to the maximum ion current in the IZ-curve, I = 9.3 na) of the IZ-curves on the living fibroblast shown in Fig. 1C (the cell s outline is indicated by the dashed red contour line). (B,C) Set of nine IZ-curves in a small region each (B) on the cell and (C) on the substrate (regions indicated by colored boxes in A) to illustrate the reliability of the method. It can be seen that the IZ-curves are reproducible and vary just within the statistical ion current noise. The measured relative slope of the shown IZ-curves is s / I = (24.8±1.4) 1 3 m -1 and (56.1±6.5) 1 3 m -1 (average ± standard deviation) for the cell and the substrate, respectively. These standard deviations correspond well with the estimates from the linear regression (1.1 1 3 m -1 and 6.1 1 3 m -1, respectively). (D) Estimate of the relative standard deviation of the slope σ s from the linear regression of the IZ-curves. The relative standard deviation of the slope is lower on the cell (about 4%) and larger on the substrate (about 1%). This difference is due to the fact that the ion current drops more rapidly on stiffer 3

regions of the sample and thus fewer data points contribute to the linear regression. Since the slope for infinite stiffness, s, is used for the quantification of the local sample stiffness [equation (1)] a more robust value for s was determined by averaging the slope of many IZ-curves on the substrate. (E) Histogram of the slope of the IZ-curves on the substrate. It can be seen that the variation of the slope on the substrate is well described by a Gaussian distribution. Its standard deviation σ s / I = 5 1 3 m -1 (9% of the average) is in well agreement both with the standard deviation of the IZ-curves in C and with the estimate for the standard deviation from the linear regression of the single IZ-curves shown in D. The variation of the measured slope is therefore predominantly statistical. Hence, the slope for infinite stiffness can be estimated well by the average slope on the substrate s = (4.778±.5) 1 4 m -1 (mean ± standard error of the mean). Due the noise of the measured slope also the resulting stiffness for an IZ-curve is subject to noise. (F) Relative error of the measured stiffness σ E / E on the cell, which is estimated with σ d d ( 1 ) 1 E E σ s E E s σ s s s s = based on equation (1); the values on the substrate were omitted. The relative error of the stiffness is on the order of 3 1% on the soft regions but can be significantly larger on the stiff regions. Scale bars: 15 µm. 4

Figure S3: Test for mechanical contact A B 5 z (µm) C Ion currenti /I 1..98.96.94.92.9 1µm 2r i 2r i 2α o 2 µm -.5..5 1. 1.5 Vertical pipette positionz-z (µm) 2α Figure S3. Test for mechanical contact by recording an IZ-curve on an AFM cantilever for a typical nanopipette used in this study. (A) Optical image of the pipette (left arrow) in proximity to an AFM cantilever (right arrow) (MLCT B-lever, Bruker AFM Probes) mounted on the bottom of a petri dish with the cantilever tip pointing upwards. (B) SICM topography image of the tip region of the cantilever. (C) IZ-curve on the cantilever (location indicated by cross in B) with zero applied pressure. The event of mechanical contact between the pipette tip and the cantilever can be identified by the kink in the IZ-curve (here at 92% ion current, straight arrow). At this position the cantilever started to deflect and the ion current thus did not decrease any further at first. This proves that for 98% current this pipette was not in mechanical contact with the sample. The inset shows scanning electron microscopy images of the tip region of the pipette used here, taken at angles of 45 (left image) and 9 (right image) relative to the pipette axis. The pipette opening was almost perfectly circular since the ratio of the inner opening radius r i = 45 ± 2 nm to the projected inner opening radius r i = 31 ± 2 nm is approximately 2 (which is expected for a viewing angle of 45 ). The inner half cone angle was found to be typically α = 4 for the pipettes used here (estimated from the outer half cone angle α o α r o / r i ). Scale bars: 5 µm (A) and 1 µm (B). 5

Figure S4: Influence of cytochalasin D on cell stiffness Stiffness <E> (kpa) 4. 2. 1..4 Cyto D 3 6 9 Timet (min) 12 Figure S4. Influence of cytochalasin D on the average stiffness of the fibroblast cell shown in Fig. 3. After the addition of 2 µm cytochalasin D (arrow) the log-average stiffness E decreased within 3 min from 2.7 ±.3 kpa to.7 ±.1 kpa (factor of 3.9). A similar factor has also been observed in AFM experiments 2. 6

Figure S5: Evaluation of the lateral resolution A Height B Stiffness Zoom-In Overview C D. z (µm) 3.5 2.8 4.8 log(e/pa) E Heightz (µm) 3 2 5 nm 4 3 2 1 8 nm 1 1 2 3 4 Lateral position x (µm) StiffnessE (kpa) Figure S5. Evaluation of the lateral resolution in stiffness maps. To show that our method can achieve sub-micrometer lateral resolution a high-resolution stiffness map was recorded on a living cell using a pipette with an opening radius of r i 1 nm. (A) Overview topography image and (B) stiffness map. (C) Zoom-in topography image and (D) stiffness map recorded in the region marked by boxes in A and B. While the topography appears relatively smooth, the stiffness varies between 1 and 1 kpa and substructures of the cytoskeleton can be seen. (E) Cross section of height and stiffness across three cytoskeleton fibers (location indicated by lines in C and D). The full width at half maximum of the fiber in the middle is 5 nm; the peakto-peak distance between the two fibers on the right is 8 nm. Since the fibers are clearly resolved in the stiffness map (D), we estimate a lateral resolution of 5 8 nm, which corresponds to 5 8r i. Scale bars: 15 µm (A, B) and 5 µm (C, D). 7

Figure S6: SICM stiffness mapping with different pipette opening diameters Large pipette (r i =64nm) A D Small pipette (r i =7nm) 9 z (µm) 5 z (µm) B E C Ion currenti /I 1% 99% 98% 5.5 2.5 Cell I = 17.2 na Line fit Substrate 2 4 Vert. pipette pos.z-z (µm) log(e/pa) F 1% 99% 98% 5.5 2.5 Cell I = 3.86 na Line fit Substrate log(e/pa) 2 4 Vert. pipette pos.z-z (nm) Figure S6. SICM stiffness mapping with different pipette sizes. Stiffness maps of living cells were recorded with a large pipette (r i = 64 nm, left column) and with a small pipette (r i = 7 nm, right column). (A) Topography image, (B) stiffness map, and (C) IZ-curves on the substrate and on the cell recorded with the large pipette (V = 1 mv, positions indicated by crosses in A). (D) Topography image, (E) stiffness map, and (F) IZ-curves on the substrate and on the cell recorded with the small pipette (V = 2 mv, positions indicated by crosses in D). The following aspects can be seen by comparing the IZ-curves: First, the ion current drop occurs within a larger vertical distance for the large pipette. Second, the functional form of the IZcurves is independent of the pipette size (the IZ-curves contain different numbers of data points since they were recorded with a similar vertical approach speed and sample rate). 8

Figure S7: Verification of the numerical model SICM p = 3 kpa A B C Ion currenti /I 1% 99% Cell 98% Fit gives E = 19. kpa Substrate..5 1. 1.5 Vertical pipette positionz (µm) AFM D E F max = 6 nn F ForceF (nn) 6. 4. 2.. Cell Fit gives E = 18.5 kpa Substrate z (µm) 5 3.5 6.5 log(e/pa).4. -.4 -.8 Indentation δ (µm) Figure S7. Verification of the numerical model by directly comparing experimentally observed and calculated IZ-curves (ion current vs. vertical pipette position). (A) SICM topography image and (B) stiffness map of a fixed fibroblast, recorded with an applied pressure of p = 3 kpa. (C) IZ-curves on the cell and on the substrate (positions indicated by crosses in A). The IZ-curve on the substrate was fitted with calculated IZ-curves for infinite sample stiffness and a pipette inner half cone angle of α = 4. The only fit coefficient was the pipette opening radius, giving r i = 45 nm. This value is in agreement with the radius estimated from the maximum ion current 3 [ ri = I (πσv tan α) = 41 nm using I = 12 na, V = 1 mv, σ = 1.35 S m -1 for PBS at room temperature]. The IZ-curve on the cell was fitted with FEM data for finite stiffness while holding α and r i constant and resulted in a stiffness of E =.63p = 19. kpa. The numerical IZ-curves (fits) closely match the experimental data indicating that the finite element model describes the qualitative behavior of the ion current well. To verify the model also quantitatively, an AFM force map was recorded on the same cell afterwards: (D) AFM topography image (at the point of contact) and (E) stiffness map. An AFM cantilever with a spherical tip of radius.94 µm, a spring constant of.226 N m -1 (determined by the thermal noise calibration method 4 ) and a maximum applied force of 6 nn was used to approximately match shape and depth of the SICM and AFM indentation profiles (shown to scale in the schematics on the left in the figure). (F) Force vs. indentation curve at the same positions on the cell (positions indicated by crosses in D). Fitting the Hertz model for a spherical indenter gave a sample stiffness of E = 18.5 kpa 9

(assuming a Poisson s ratio of ν =.5). From the stiffness maps (B and E) it can be seen that a close agreement between SICM and AFM stiffness results was found. The log-average stiffness (Young s modulus) of the cell was measured as E = 18.6 kpa by the SICM and as 18.9 kpa by the AFM. Hence, the numerical model also quantitatively well describes the deformation of the sample and the resulting ion current. As known from AFM, indentation measurements on sample regions where the surface is strongly inclined or curved might be affected by artifacts. This occurs, for example, on the edges of the cell (arrows in B and E) where the cell appears relatively soft both in the SICM and the AFM stiffness map. Scale bars: 15 µm. 1

Table S1: Influence of the pipette geometry on A Geometrical parameter A for different values of inner half cone angle α and wall thickness of the pipette. inner half cone angle α 3 4 5 wall thickness (in units of r i ).25.5 1..25.5 1..25.5 1. geometrical parameter A.46.4.33.29.26.21.21.18.15 11

Supplementary Note: Fluid flow in a conical pipette The maximum volumetric flow rate through the pipette is 6 = α (S1) η Q 3πtan 3 r 8 i p where η is the viscosity of the fluid (η =.7 mpa s for water at 37 C). The fluid velocity is maximum in the center of the pipette opening. Since the flow profile is parabolic (Hagen- Poiseuille-like) the maximum fluid velocity is twice the average fluid velocity in the pipette opening: Q vmax = 2v 3tan avg = 2 = α r 2 4 i p. (S2) πr η i For the pipettes and the applied pressures used here a typical fluid velocity is v max 1 cm s -1. An upper limit of the Reynolds number, Re, can be estimated as Re ρ v r η 3tanα ρ 4 η max i = 2 r 2 i p.1 (S3) where ρ is the density of the fluid (ρ = 1 3 kg m -3 for water). This is far below the critical Reynolds number, Re crit, for turbulent flow in a cone 7 Re 12 crit = 2 (S4) tanα using a half cone angle of α = 4. The fluid dynamics are therefore dominated by viscous flow. However, for opening radii larger than about 1 µm turbulent flow might set in. The hydrodynamic timescale of the flow can be estimated as τ r i = 4η 1µs. (S5) vmax 3p tanα 12

Movie S1: Time-lapse imaging of a live NIH3T3 fibroblast cell Movie S1. Time-lapse imaging of a live NIH3T3 fibroblast cell with addition of cytochalasin D. Eleven consecutive frames of height (left) and stiffness (right) images are shown (including those in Fig. 3). Acquisition time: 15 min per frame (up-scan). The movie file is available online (see ESI). 13

References 1. B. Sakmann and E. Neher, Single-Channel Recording, Springer, Heidelberg, 1995. 2. C. Rotsch and M. Radmacher, Biophys. J., 2, 78, 52-535. 3. T. K. Chowdhury, J. Phys. E: Sci. Instrum., 1969, 2, 187-19. 4. S. M. Cook, T. E. Schäffer, K. M. Chynoweth, M. Wigton, R. W. Simmonds and K. M. Lang, Nanotechnology, 26, 17, 2135-2145. 5. N. Gavara and R. S. Chadwick, Nat Meth, 21, 7, 65-654. 6. D. Sánchez, N. Johnson, C. Li, P. Novak, J. Rheinlaender, Y. Zhang, U. Anand, A. Praveen, J. Gorelik, G. Frolenkov, C. Benham, M. Lab, V. Ostanin, T. E. Schäffer, D. Klenerman and Y. E. Korchev, Biophys. J., 28, 95, 317-327. 7. H. Blasius, Z. Math. Phys., 191, 58, 225-233. 14