Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Similar documents
Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement Single-range transmitters for general applications

ED 701 General Industry Pressure Transmitter

Pressure transmitters for industrial applications MBS 32 and MBS 33

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Pressure Transmitter ED 701

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

EX-EMERGENCY LIGHT FITTINGS

1 Overview. Pressure Measurement Transmitters for applications with basic requirements (Basic) SITRANS P310 - Technical description

Relative pressure transmitter type 520

ISEmax CAM40/CAS40. Technical Information

Operating Instructions for Digital Manometer. Model: MAN-SD

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

PRODUCT CATALOGUE PREssURE switch

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

Exchangeable measuring insets SensyTemp TSA101

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Installation guide 862 MIT / MIR

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Field IT 50T Series Transmitters

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Cartridge Valves Technical Information. Quick reference

Z7A. Load cells. Special features. Data sheet. Wiring code

ATEX/IECEx RTD temperature probe

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Ex floating switches and Ex immersion probes

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Single point load cells

Direct-operated 2/2-way compact solenoid valves Type EV210A

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Non-Contact Safety Systems CMS

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

Reflex-Radar BM 100 A

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

Solenoid valves 2/2-way direct-operated type EV210A

PHOENIX CONTACT - 04/2016. Features

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Switches in conformity with ATEX directive

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Type UB1 Load Cell. Option Stainless steel cable gland

THREE HOLE SPLICE CLEVIS FOR B52 Standard finishes: ZN, GRN Wt./C 126 Lbs. (57.1 kg)

Direct-operated 2/2-way solenoid valves Type EV210B

Field mounted Temperature Transmitter TF212/TF212-Ex

FLOW SENSOR FOR LIQUID MEDIA Serie 210

Physikalisch-Technische Bundesanstalt

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Pressure. 1 Fitting PA R - N R2

Fitting PS P - B - R2

Surface-mounting Thermostats ATH Type Series

Surface-mounting thermostats Series ATH

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

8 Installation Equipment

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

I Ex d/e Switch- and Control-Equipment I

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

Operating instructions Pressure sensor PN / / 2007

ISEmax CAS40D. Technical Information

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

Type M4 - SON - SO - MS

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Solenoid valves Type EVUL

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

Analogue Meters CQ2x07 series

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

Installation Equipment

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Industrial Resistance Thermometers according to DIN Model MWD

Thermal-Magnetic Circuit Breaker 2210-T2...

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

AC axial compact fan

Ring-Torsion Load Cells RTB

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Safir-M smart. Features. Dot-matrix display and controls. Industries. Applications. y Reference accuracy, % FS

maintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

Transcription:

Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level measurements. The s are available for various measuring ranges and with explosion protection as an option. A junction box and a cable hanger are available as accessories for simple installation. Benefits Compact design Simple installation Small error in measurement (0.3 %) Degree of protection IP68 Application s are used in the following branches for example: Oil and gas industries Shipbuilding Water supply For use in pressureless/open tanks and wells, mode of operation and wiring diagram On one side of the sensor, the diaphragm is exposed to the hydrostatic pressure which is proportional to the submersion depth. This pressure is compared with atmospheric pressure. Pressure compensation is carried out using the vent pipe in the connection cable. The hydrostatic pressure of the liquid column acts on the sensor diaphragm, and transmits the pressure to the piezo-resistive bridge in the sensor. The output voltage of the sensor is applied to the electronic circuit where it is converted into an output current of 4 to 20 ma. The cable of the 7MF570 transmitter must always be connected in the supplied junction box. The junction box has to be installed near the measuring point. If the medium is anything other than water, it is also necessary to check compatibility with the specified materials of the transmitter. Integration Vent pipe Screen s have a front-flush piezoresistive sensor with stainless steel diaphragm. These pressure transmitters are equipped with an electronic circuit fitted together with the sensor in a stainless steel housing. The cable also contains a strength cord and vent pipe. The diaphragm is protected against external influences by a protective cap. The sensor, electronic circuit and cable are sealed in a common housing of small dimensions. The pressure transmitter is temperature-compensated for a wide temperature range. To measuredvalue processing Venting pipe Junction box 7MF570-8AA, opened To transmitter 7MF570 /27

Measuring point setup, in principle Technical specifications SITRANS P MPS pressure measurement transmitter (submersible sensor) Mode of operation Measuring principle piezo-resistive Input Measured variable Hydrostatic level Measuring range Maximum operating pressure 0... 2 mh 2 O (0... 6 fth 2 O).4 bar (20.3 psi) (corresponds 0... 4 mh 2 O (0... 2 fth 2 O).4 bar (20.3 psi) (corresponds 0... 5 mh 2 O (0... 5 fth 2 O).4 bar (20.3 psi) (corresponds 0... 6 mh 2 O (0... 8 fth 2 O) 3.0 bar (43.5 psi) (corresponds to 30 mh 2 O (90 fth 2 O)) 0... 0 mh 2 O (0... 30 fth 2 O) 3.0 bar (43.5 psi) (corresponds to 30 mh 2 O (90 fth 2 O)) 0... 20 mh 2 O (0... 60 fth 2 O) 6.0 bar (87psi) (corresponds to 50 mh 2 O (50 fth 2 O)) Output Output signal 4... 20 ma Measuring accuracy Acc. to IEC 60770- Error in measurement at limit setting 0.3 % of full-scale value (typical) incl. hysteresis and reproducibility Influence of ambient temperature Zero and span... 6 mh 2 O (3... 8 fth 2 O) 0.45 %/0 K of full-scale value 6mH 2 O ( 8 fth 2 O) 0.3 %/0 K of full-scale value Long-term stability Zero and span... 6 mh 2 O (3...8 fth 2 O) 6mH 2 O ( 8 fth 2 O) Rated conditions Ambient conditions Process temperature Storage temperature Degree of prot. to DIN EN 60529 Pressure transmitter Cable Electrical connection Material Seal diaphragm Enclosure Gasket Connecting cable Power supply Terminal voltage on pressure transmitter U B 0.25 % of full-scale value/year 0.2 % of full-scale value/year -0... +80 C (4... 76 F) -40... +00 C (-40... +22 F) IP68 0.4 kg ( 0.88 lb) 0.08 kg/m ( 0.054 lb/ft) Cable with 2 conductors with screen and vent pipe, strength cord (max. 300 N (67.44 lbf) Stainl. steel, mat. no..457/36ti Stainl. steel, mat. no..457/36ti Viton Either PE/HFFR sheath (non-halogen) or FEP sheath 0... 36 V DC 0... 30 V DC for transmitter with intrinsic safety explosion protection Certificates and approvals Germanischer Lloyd (GL) GL 75360-09 HH Bureau Veritas (BV) BV 270/A0 BV Det Norske Veritas (DNV) DNV A-2553 Drinking water approval (ACS) ACS ACC NY 04 Drinking water approval (WRAS) WRAS 055 GOST GOST-R, GOST FR.C.30.004.A/ 42376/ und PPC 00-04 505 The transmitter is not subject to the pressure equipment directive (PED 97/23/EC) Explosion protection Intrinsic safety "i" SEV 0 ATEX 049 - Marking II G Ex ia IIC T4 Ga Junction box Application for connecting the transmitter cable 0.2 kg (0.44 lb) Electrical connection 2 x 3-way (28 to 8 AWG) Cable entry 2xM20x.5 Enclosure material polycarbonate Vent pipe for atmospheric pressure Screw for cable strength cord Rated conditions Degree of prot. to DIN EN 60529 IP65 Cable hanger Application for mounting the transmitter 0.6 kg (0.35 lb) Material Galvanized steel, polyamide /28

Selection and Ordering data Article No. Order code for gauge pressure (submers- ible sensor) With PE cable Measuring range Cable length L 0...2mH 2 O 0 m } C 0...4mH 2 O 0 m } D 0...5mH 2 O 25 m } B 0...6mH 2 O 25 m } E 0...0mH 2 O 25 m } F 0...20mH 2 O 25 m } G 0...6ftH 2 O 32 ft K 0... 2 fth 2 O 32 ft L 0... 8 fth 2 O 82 ft M 0... 30 fth 2 O 82 ft N 0... 60 fth 2 O 82 ft P Special cable lenght/special measuring range ) Please add -Z to Article No. and 9 A H.. + Y 0 specify Order code and plain text. Note: Indication of measuring range Y0 is always necessary. 3 m H A 5 m H B 7 m H C 0 m H D 5 m H E 20 m H F 25 m H G 30 m H H 40 m H J 50 m H K 60 m H L 70 m H M 80 m H N 90 m H P 00 m H Q 25 m H R 50 m H S 75 m H T 200 m H U 225 m H V 250 m H W 275 m H X 300 m H 2 A 350 m H 2 B 400 m H 2 C 450 m H 2 D 500 m H 2 E 550 m H 2 F 600 m H 2 G 650 m H 2 H 700 m H 2 J 750 m H 2 K 800 m H 2 L 850 m H 2 M 900 m H 2 N 950 m H 2 P 000 m H 2 Q Selection and Ordering data Article No. Order code for gauge pressure (submers- ible sensor) With FEP cable Measuring range Cable length L 0...2mH 2 O 0 m } 5 C 0...4mH 2 O 0 m } 5 D 0...5mH 2 O 25 m } 5 B 0...6mH 2 O 25 m } 5 E 0...0mH 2 O 25 m } 5 F 0...20mH 2 O 25 m } 5 G 0...6ftH 2 O 32 ft 5 K 0... 2 fth 2 O 32 ft 5 L 0... 8 fth 2 O 82 ft 5 M 0... 30 fth 2 O 82 ft 5 N 0... 60 fth 2 O 82 ft 5 P Special cable lenght/special measuring range ) Please add -Z to Article No. and 9 A H.. + Y 0 specify Order code and plain text. Note: Indication of measuring range Y0 is always necessary. 3 m H 5 A 5 m H 5 B 7 m H 5 C 0 m H 5 D 5 m H 5 E 20 m H 5 F 25 m H 5 G 30 m H 5 H 40 m H 5 J 50 m H 5 K 60 m H 5 L 70 m H 5 M 80 m H 5 N 90 m H 5 P 00 m H 5 Q 25 m H 5 R 50 m H 5 S 75 m H 5 T 200 m H 5 U 225 m H 5 V 250 m H 5 W 275 m H 5 X 300 m H 6 A 350 m H 6 B 400 m H 6 C 450 m H 6 D 500 m H 6 E 550 m H 6 F 600 m H 6 G 650 m H 6 H 700 m H 6 J 750 m H 2 K 800 m H 6 L 850 m H 6 M 900 m H 6 N 950 m H 6 P 000 m H 6 Q /29

Selection and Ordering data Article No. Order code Dimensional drawings for gauge pressure (submersible sensor) Explosion protection None } with type of protection "intrinsic } 2 safety" (Ex II G Ex ia IIC T4) Approvals with drinking water approval to WRAS and ACS 6 Further designs Order code Quality inspection certificate (factory C calibration) to IEC 60770-2, add -Z to Article No. and add Order code. Indication of measuring range (only at Y0 special cable lengths) in... to... mh 2 O or... to... fth 2 O Accessories (as spare part) Article No. Junction box 7MF570-8AA for connecting the transmitter cable Cable hanger 7MF570-8AB for attachment of transmitter } Available ex stock We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Power supply units see Chap. 7 "Supplementary Components". s, dimensions in mm (inch) 79 (3.) Protective cap Ø 27 (. diam.) 58 (6.2) Cable sheath + (brown) Vent pipe Strength cord (white) - (blue) Screen Cable sheath 8.3 (0.33) diam. (black, PE/HFFR) Flexible cable with 0.5 mm 2 (0.00078 inch 2 ) cross-section Vent pipe (0.04) diam. (inner diameter) Protective cap with 4 x 3 diam. (4 x 0.2 diam.) holes (black, PA) 50 (.97) M20x,5 Venting valve L Mounting hole 57 (2.25) 22 (0.87) 30 (.2) 94 (3.7) ) Special measuring ranges of between 0... mh 2 O (0... 3 fth 2 O) and 0... 200 mh 2 O (0... 656 fth 2 O) and special cable lengths of up to 000 m (328 ft) are possible. With Ex versions the max. custom cable length is 50 m (50 ft). The length of free hanging cable should not exceed 375 m (230 ft). Note: Due to mounting reasons it has to be considered that the cable always must be longer than the height of the liquid column to be measured. 65 (2.56) M20x,5 22 (0.87) 30 (.2) Junction box, dimensions in mm (inch) 9 (0.75) 75 (6.9) 48 (.9) Cable hanger, dimensions in mm (inch) /30

More information Determination of the measuring range in case of media with a density 000 kg/m 3 (medium water) H ρ Calculation of the measuring range: p = x g x H with: = density of medium g = local acceleration due to gravity H = maximum level Example: Medium: Diesel fuel, = 850 kg/m 3 Acceleration due to gravity: 9.8 m/s 2 Start-of-scale: 0 m Maximum level: 6.2 m Cable length: 7 m, FEP cable Calculation: p = 850 kg/m 3 x 9.8 m/s 2 x 6.2 m p = 5698.7 N/m 2 p = 57 mbar Transmitter to be ordered: 7MF570-9AA02-Z, H5C + Y0 Y0: 0... 57 mbar /3