AL 22 / 26 Classic Инструкция по использованию FIN RUS / / Rev.01.07

Similar documents
Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

Automatic Level NP-732

22X Builder s Transit Level Model No Instruction Manual

22X Builder s Level Model No Instruction Manual

取扱説明書 /INSTRUCTION MANUAL 自動レベル /AUTOMATIC LEVEL AT-B2/B3/B4 FC10386-A012-02

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

Surveying Instruments. B Series B20 B30 B40. Automatic Levels

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

WATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

5-25x56 PMII PSR With Double Turn

H050 E 97.1.DF.2. Automatic Levels AS-2 / AS-2C

Collimation with a Takahashi collimating scope

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

C4 PLUS RIFLESCOPES User Guide

5-25x56 PMII PSR Illuminated with Double Turn

ZFK 4 X 25. Description and Utilization Instructions

P4Xi TACTICAL Riflescope TECHNICAL MANUAL

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

Electron Microscopy Sciences INSTRUCTION MANUAL. Stereo Microscopes Non-illuminated Stands

EPOCSELFIR LACITCATiX5T TECHNICAL MANUAL

~.LIETZ ~. LI ETZ INSTRUCTION MANUAL DOUBLE CENTER THEODOLITE TM-20C THE LIETZ COMPANY E. Del Arno Blvd. Carson, Ca (213)

CIV : THEODOLITE ADJUSTMENT

RT-6 Riflescopes. User Guide

NcSTAR SHOOTER II SERIES SCOPE

BINOCULAR. 50 mm Tactical Binocular Manual HD R/T

Directions for use

S5 SERIES Rifl escope Rifl

Carlson CR Robotic/Reflectorless Total Station

Operating Manual 1.1-4x24 Zenith x24 Zenith

Spotting Scope Instruction Manual

FIELD GUIDE FOR HORUS SCOPES

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

DWT-10 Instruction Manual

The 50mm Viper R/T binocular is equipped with the Vortex R/T Ranging reticle, designed to assist the user in calculating distances.

Second Focal Plane MOA

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE

C A S S I N I TRACKER

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

2-7x32. Instruction manual

RP-100 TELESCOPE Instruction Manual

Assembly Manual for the Brevard Astronomical Society 16 inch F4.5 Dobsonian Telescope Brevard Astronomical Society P.O. Box 1084 Cocoa, FL 32922

Instruction Manual. Made in Japan

LEAPERS, INC. RED/GREEN DOTS

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE (PASILL2)

Altazimuth Mount. Altazimuth Mount

RP-200 TELESCOPE Instruction Manual

The Vortex Razor HD Gen II-E 1 6x24 Riflescope

USER MANUAL. Core TX Riflescope Series

INTREPID x 50 Riflescope

Dual Red or Green Electronic Dot Sight Instruction Manual

SURVEYING 1 CE 215 CHAPTER -3- LEVEL AND LEVELING

3B SCIENTIFIC PHYSICS

LT8-300LTU Owner s Guide

The Vortex. Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Elevation. Adjustment Dial.

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

HD Gen II 1 6x24 Riflescope. The Vortex Razor

30 mm Diameter Main Tube

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student

Appendix 2: Disassembling and Assembling the Telescopes and the Celestron Equatorial Mounts

USER MANUAL RIFLESCOPES. Triple Duty & Tactical Series. English / Francais / Español / Deutsch

30 mm Diameter Main Tube 1-4x24 Models

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

Coma Correction. Diagram. Introduction

Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Radius Bar. Reticle Focus. Elevation Adjustment Knob

x Builders Level Service Manual

ZENITHSTAR 61 APO. Owner s Manual ver

The Vortex Razor HD Gen II 1 6x24 Riflescope

The Vortex Golden Eagle Riflescopes

Platinum Series. 6-30x56 Front Focal Plane Scope. with Patent Pending DEKA MIL Reticle. DEKA MIL reticle for unsurpassed accuracy at long range

1 YEAR LIMITED WARRANTY TELESCOPES

EE 1/3.5х14 U EE 1/3.5х14 U

???? The Vortex Crossfire II Riflescopes

RP-400 TELESCOPE Instruction Manual

UNIT-4 THEODOLITE SURVEYING

RP-300 TELESCOPE Instruction Manual

RIFLESCOPE RIFLESCOPE MANUAL

Observing Procedure for C11 GPS

THE HAVERFORD UNIVERSITY S STRAWBRIDGE OBSERVATORY S OF THE 16 MEADE. A quick guide to using the 16 Meade Schmidt-Cassegrain Telescope

product manual H-4204 Proving Ring Penetrometer

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

S7SERIES. Rifl escope

instruction Manual #9974 Customer Support (800) IN 293 Rev. C 02/09

Introduction to the Microscope

Second Focal Plane MRAD

1-6 x 24 Second Focal Plane MOA

CBRD30CP3 & BOWRD30CP INSTRUCTION MANUAL

PoleMaster User Manual (Northern Hemisphere)

USER MANUAL. EZEKIEL 3-30x56. Riflescope. English / Francais / Español / Deutsch

GT-510/510L series Instruction Manual

MARINE BINOCULARS ZHUMELL 7X50 MARINE BINOCULARS WITH COMPASS AND RETICLE

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

4-14X44 FRONT FOCAL PLANE SCOPE WITH ARC-2 MOA RETICLE

CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION

C A S S I N I. MODEL : C EQ3 900mm X 135mm COSMO BRANDS INC.

USER MANUAL. Core HX Riflescope Series SM13068HBR

Transcription:

080.82 / 080.83 / Rev.01.07 D GB NL DK F E I PL FIN RUS Bedienungsanleitung 3-8 Operating instructions 9-14 Gebruiksaanwijzing 15-20 Betjeningsvejledning 21-26 Mode d emploi 27-32 Instrucciones para su uso 33-38 Istruzioni d'uso 39-44 Instrukcja Obsługi 45-50 Käyttöohje 51-56 Инструкция по 57-62 использованию

2

1 13 2 3 4 5 12 11 10 9 8 7 6 1 Objektive 2 Telescope 3 Sights 4 Focussing knob 5 Ocular (eyepiece) 6 Lens cap 7 Compensator lock 8 Levelling screw 9 Horizontal dial 10 Calibration screw, levelling bubble 11 Levelling bubble 12 Mirror 13 Lateral fine adjustment Sturdy and reliable levelling instruments for the building and construction industry, with a highperformance lens producing a bright image. Self-levelling of the horizontal collimation line by a precise compensator with magnetic damping. Safe transport of the instrument in its container, with the compensator being locked. Distance estimation with the aid of the markings on the crosshairs and easy conversion of the achieved readings from centimetres to metres (multiplier 100). Handy adjustable folding mirror for simple adjustment with the aid of the levelling bubble. Iron rear- and foresight for rapid pick-up of aim. Comfortable operating knobs allow a simple and timesaving operation. Dust- and waterproof. ENGLISH 9

Installation Please note Prior to its use, the instrument should be given time to adopt the prevailing temperature of the area. Positioning the level 1. Adjust height of the instrument to a comfortable position (telescope should be eye-level). When working on soft ground, tread legs of tripod firmly into the ground. 2. Place the instrument onto the tripod and fix it by turning the fixing screw into the tripod socket. 3. Levelling bubble to be centred by operating the levelling screws. Advice for positioning Turn horizontal dial onto position 0, before doing so, levelling screws are to be slightly loosened. Now, by using only the rear levelling screws, the levelling bubble is to be centred (see drawing). Adjust folding mirror in a way that the levelling bubble is well visible. a) Turn both levelling screws in opposite senses: b) Turn both levelling screws into the same direction: 4. Focus crosshairs by turning the focusing ring on the lens - background should be bright. Alignment 1. Initial alignment of the telescope towards the graduated staff is done by hand, using the iron sights. 2. Focus the image of the staff, by operating the focusing knob, turn crosshairs onto the staff centre. 3. Make sure focusing is free of parallax. The focusing is alright when crosshairs and graduation of the staff don't change their positions even when looked at from different angles (keep changing position of the eye in front of the eyepiece). 12 ENGLISH

Please note: Prior to its use, the instrument should be given time to adopt the prevailing temperature of the area. Alignment 1. Initial alignment of the telescope towards the graduated staff is done by hand, using the iron sights. 2. Focus the image of the staff, by operating the focusing knob, turn crosshairs onto the staff centre. 3. Make sure focusing is free of parallax. The focusing is alright when crosshairs and graduation of the staff don't change their positions even when looked at from different angles (keep changing position of the eye in front of the eyepiece). Important: Remaining inclinations of the crosshairs which are left after the levelling bubble has been centred will be eliminated by the compensator. The compensator, however, will not eliminate any inclinations caused by faulty calibration of the levelling bubble or the crosshairs. Therefore, the positions of both gadgets should be checked before measuring (see calibration). Determination of a height difference 1. Place instrument halfway between the positions of staves A and B. Aim instrument at staff A and read the value of the graduation of the staff at your crosshairs (A = 140 cm). Turn instrument towards rod B and get the reading from the graduation (B = 90 cm). A ½L ½L 2. The difference (A-B) results in a height difference H = +50 cm between B and A. The point B is 50 cm higher than point A. The difference H turns negative when point B is lower than point A. Important: A slight deviation of the crosshairs does not cause any misreadings provided the instrument has been placed approx. midway between the positions of the two staves A and B. B 10 ENGLISH

Staving out a height A B x H=120 cm 1. Place the staff on a point with a known height. Read value (A) from the graduation (A = 90 cm) Add the read value to the height of the known point. Now deduct the height of the point to be staved out from this value (height on the crosshairs). H+A-x=B 2. Keep moving the levelling staff vertically until the calculated difference B can be read on the graduation. Afterwards, mark the height of the toe of staff. Distance determination 1. Read values of the upper graduation mark (O = 1,44 m) and the lower graduation mark (U = 1,36 m). 2. Multiply the difference by the factor 100 (E = 100 x e), the result is the distance E = 8 m. 14 e O=1,44 m U=1,36 m Advice: In order to get reliable results, the following rules should be obeyed: make sure the distances to the aims are equal see to an exact vertical positioning of the staff avoid tripod and staff from sinking into the ground avoid reading errors Angle measurement 1. Attach the string of the plumb bob to the hook and then place the tripod over the point in a way that the plum bob is already close to the point. The top of the tripod should be as horizontal as possible. Tread legs of tripod firmly into the ground. 2. Attach instrument to tripod and fix it. Now centre the plumb bob exactly over the point by adjusting the lenghts of the tripod legs or by changing the position of the instrument on the tripod. 3. With the aid of your iron sights, aim telescope at the first aim, align by using the lateral fine adjustment. First aim = known point. Now turn knurled ring until the index and the zero position of the horizontal dial are congruent (turn dial onto zero). 4. Aim telescope at the second aim and read the angle function under the index marking. ENGLISH 11

Measuring methods Distance determination 1. Read values of the upper graduation mark (O = 1,44 m) and the lower graduation mark (U = 1,36 m). 2. Multiply the difference by the factor 100 (E = 100 x e), the result is the distance E = 8 m. Advice for 3.1-3.3: In order to get reliable results, the following rules should be obeyed: - make sure the distances to the aims are equal - see to an exact vertical positioning of the staff - avoid tripod and staff from sinking into the ground - avoid reading errors Angle measurement 1. Attach the string of the plumb bob to the hook and then place the tripod over the point in a way that the plumb bob is already close to the point. The top of the tripod should be as horizontal as 14 ENGLISH e O=1,44 m U=1,36 m possible. Tread legs of tripod firmly into the ground. 2. Attach instrument to tripod and fix it. Now centre the plumb bob exactly over the point by adjusting the lenghts of the tripod legs or by changing the position of the instrument on the tripod. 3. With the aid of your iron sights, aim telescope at the first aim, align by using the lateral fine adjustment. First aim = known point. Now turn knurled ring until the index and the zero position of the horizontal dial are congruent (turn dial onto zero). 4. Aim telescope at the second aim and read the angle function under the index marking. E W

Calibration Levelling bubble 1. Control: Set horizontal dial onto 0. Place bubble right into the centre of the circle on the levelling bubble by turning the levelling screws. Turn telescope through 180 /200 gon. 2. Adjustment: In case the bubble is now out of the a centre marking, set half of the deviation "a" which is (fi a) by operating the three calibration ½a screws on the levelling bubble. After that, adjust levelling bubble by using the levelling screws, then check calibration by turning the whole instrument through 180 /200 gon. 3. Repeat control and calibration until the bubble of the levelling bubble remains in the inner circle after each turn of the instrument. Crosshairs 1. Control: Place instrument midway between two fixed staves A and B which are some 30 to 40 metres apart. At the point A on the staff, read the value a 1 and at the point B on the other staff, secure the value b 1. Calculate the height difference (a 1 - b 1 ). The result you get is right, even with the crosshairs dejusted, because the distances between both staves are equal. L=30-40 m a 1 b 1 Now place instrument in a distance of approx. 2 m away from staff A and read the value a 2. Next, turn the instrument and aim the level at point B on the staff. Read the value b 2 and calculate the height difference, which is (a 2 - b 2 ). 2 m ½L ½L b 2soll a 2 b 2 The adjustment of the level is correct when you get the reading (a 1 - b 1 ) = (a 2 - b 2 ). This means that the values of the height differences achieved with the first and the second measurement are equal, and the instrument operates error-free. 12 ENGLISH

In case the height differences are not equal, the instrument has to be adjusted according to the following procedure: 2. Adjustment: Calculate the value b 2soll = a 2 - a 1 + b 1 and adjust the crosshairs, with the aid of 1 the calibration screws, which are visible behind the eyepiece once the 2 protective cap has been removed, to the calculated setting b 2soll b 2soll = a 2 - a 1 +b 1 b 2soll. b 2soll = a 2 -a 1 +b 1 a) In case b 2 is smaller than b 2soll, loosen screw 1 and move crosshairs by turning screw 2 until b 2 = b 2soll. After that, carefully tighten calibration screws against each other. b) In case b 2 is larger than b 2soll, loosen screw 2 and adjust crosshairs by operating screw 1 until B 2 = b 2soll. After that, carefully tighten calibration screws against each other. Repeat control of the adjustment until you get the result (a 1 - b 1 ) = (a 2 - b 2 ). 3. Vertical adjustment: The crosshairs can be rotated to achieve vertical adjustment (loosen calibration screws). Afterwards, the instrument must be adjusted horizontally again. Then screw on the protective cap again. Formula: (a 1 -b 1 )=(a 2 -b 2 ) b 2soll = a 2 -a 1 +b 1 is the result of: b 2soll = a 2 -(a 1 -b 1 ) Care and storage 1. Use a soft cloth to clean instrument from dust and dirt. 2. Carefully clean lens and ocular with a soft and clean cloth, cotton or a soft brush, use no liquids other than pure alcohol. Do not touch any surfaces of the lenses. 3. After use under wet weather conditions, container and instrument are to be field-cleaned and then, at home, left to dry thoroughly with the container open. 4. For carrying the instrument over long distances, it is best to place it in its container. Attention: Levelling screws to be turned all the way in. ENGLISH 13

Technical data Standard deviation 2,5 mm / km (AL 22) Standard deviation 1,5 mm / km (AL 26) Telescope: Magnification 22 fach (AL 22) 26 fach (AL 26) mm / cm- estimation to 85 m / to 170 m (AL 22) to 100 m / to 200 m (AL 26) Minimum range 0,5 m Objective diameter 30 mm (AL 22) 34 mm (AL 26) Field of view 1 30' Iron sights fine Compensator: Damping magnetic Range of operation ± 15' Accuray 0,5" Compensation time < 2 s Horizontal dial 360 /400 gon: Graduation 360 - horizontal circle 1 Graduation 400 gon - horizontal circle 1 gon Levelling bubble: Accuracy 8' / 2 mm General: Operating temperature - 10... + 40 C Storage temperature - 20... + 70 C Tripod adapter 5/8 thread Weight 1,4 kg Dimensions 200 x 130 x 130 mm (Subject to technical alterations) 14 ENGLISH

D GB NL DK F E Zubehör (optional) Accessories (optional) Accessoires (optioneel) Tilbehør (ekstra-udstyr) Accessoires (en option) Accesorios (opcional) I PL FIN RUS AL 22 / 26 Classic Accessori (optional) Akcesoria (opcja) Lisämahdollisuuksia valinnaisvarusteilla Полезные принадлежности Art.-Nr: 080.06 4 m: Art.-Nr: 080.40 5 m: Art.-Nr: 080.41 max. 165 cm min. 95 cm max. 160 cm www.laserliner.com 63

D GB NL DK F E Service- und Versand-Anschrift Service- and Shipping Address Service- en verzendadres Service- og Postadresse Livraison et expédition Dirección de servicio y de envío I PL FIN RUS Indirizzo di assistenza e di spedizione Serwis i sprzedaż Service- og Postadresse Адрес службы сервиса и для отправки Umarex GmbH & Co KG Laserliner Möhnestraße 149, 59755 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: -333 laserliner@umarex.com GmbH & Co KG Donnerfeld 2 59757 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: -333 www.laserliner.com