Scintillating Crystals and their Applications in Particle and Nuclear Physics November 17-18, 2003

Similar documents
Scintillation Detectors

BSO Crystals for the HHCAL Detector Concept

Positron Emission Tomography

Space Application of Geant4 for the Japanese X-ray X Gamma-ray Mission

Chapter 4 Scintillation Detectors

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

Characterization and Monte Carlo simulations for a CLYC detector

Recent advances and future perspectives of gamma imagers for scintimammography

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

PET. Technical aspects

OPPORTUNITY TO JOIN IEEE AND NPSS

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Inorganic Scintillators

Key words: avalanche photodiode, soft X-ray detector, scintillation γ-ray detector, imaging device PACS: 07.85;95.55.A;85.60.D

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

Non-proportionality of organic scintillators and BGO

Calibration of A Small Anode Germanium Well Detector

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

arxiv: v1 [physics.ins-det] 29 Jun 2011

Radionuclide Imaging MII Positron Emission Tomography (PET)

Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET

Platinum resistance. also wirewound versions. eg

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

Scintillation detectors

The 46g BGO bolometer

Ultra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals

Large Size LYSO Crystals for Future High Energy Physics Experiments

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Energy Resolution of Scintillation Detectors New Observations

Compton suppression spectrometry

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Preparatory experiments for cold-neutron induced fission studies at IKI

Nuclear Instruments and Methods in Physics Research A

INORGANIC crystal scintillators are widely used in high

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

DEVELOPMENT OF ADVANCED NEUTRON INDUCED PROMPT GAMMA- RAY ANALYSIS SYSTEM FOR SURVEY OF ANTI-PERSONNEL MINES

LSO/LYSO Crystal Development Ren-yuan Zhu

CHIPP Plenary Meeting University of Geneva, June 12, 2008 W. Lustermann on behalf of the AX PET Collaboration

Chemical Engineering 412

05 - Scintillation detectors

A NEW GENERATION OF GAMMA-RAY TELESCOPE

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE

Calibration and Monitoring for Crystal Calorimetry

Design of a Lanthanum Bromide Detector for TOF PET

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Efficiency. Calculations for Selected Scintillators. > Detector Counting. Efficiency. > Photopeak Efficiency of Various Scintillation Materials

Timing and Energy Response of Six Prototype Scintillators

GAMMA RAY SPECTROSCOPY

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

6: Positron Emission Tomography

Charge collection in PET detectors

Application of positrons in materials research

IN the last decade, cerium doped silicate based heavy

First Results and Realization Status of a Proton Computed Radiography Device

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

Development of a High Precision Axial 3-D PET for Brain Imaging

Radioactivity and Ionizing Radiation

REVIEW OF CRYSTAL CALORIMETERS

HIGH-PRESSURE HELIUM-3 SCINTILLATION POSITION-SENSITIVE DETECTOR OF THERMAL NEUTRONS

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Application of NaI(T1) Scintillation Detector to Measurement of Tritium Concentration*

arxiv:physics/ v1 3 Aug 2006

Feasibility of a new polarized active detector for low-energy ν

Radiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors

SCINTILLATION DETECTORS AND PM TUBES

XMASS: a large single-phase liquid-xenon detector

Scintillation Detectors

Sample Spectroscopy System Hardware

Gamma Spectroscopy. References: Objectives:

New Scintillators for the Border Monitoring Equipment

Introduction to Radiation Monitoring

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

Waveform Analysis for DM-Ice17. Zachary Pierpoint University of Wisconsin - Madison October 21, 2013 Yale Weak Interactions Discussions Group

Introduction to scintillators

Detector Array for Low Intensity radiation. DALI and DALI2. S.Takeuchi, T.Motobayashi. Heavy Ion Nuclear Physics Laboratory, RIKEN

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Detection of gamma-rays from winter thunderclouds along the coast of Japan Sea

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Mayneord-Phillips Summer School St Edmund Hall, University of Oxford July Proton decays to n, e +, ν

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Characterization of the Lanthanum Chloride Scintillation Detector

A new scintillator detector for nuclear physics experiments: the CLYC scintillator

High-efficiency and fast-timing scintillators

Scintillation Detectors

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

Scintillation Detectors

3. Perturbed Angular Correlation Spectroscopy

Investigation of fast neutron spectroscopy capability of 7 Li and 6. Li enriched CLYC scintillator for nuclear physics experiments

The Use of Neutron Generators for the Detection of Illicit Materials in the Sea Transportation System

Optical transmission radiation damage and recovery stimulation of DSB:Ce 3+ inorganic scintillation material

Large volume LaBr 3 :Ce detectors and HECTOR +

Laboratory 3&4: Confocal Microscopy Imaging of Single-Emitter Fluorescence and Hanbury Brown and Twiss setup for Photon Antibunching

Time Structure in Dual Readout Calorimeters. Michele Cascella (UCL) for the RD52 Collaboration 1

2010 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Transcription:

Scintillating Crystals and their Applications in Particle and Nuclear Physics November 17-18, 2003 Takayuki Yanagida, Hiromitsu Takahashi, Daisuke Kasama, Takeshi Ito, Hisako Niko, Motohide Kokubun, and Kazuo Makishima Department of Physics, University of Tokyo Takagimi Yanagitani and Hideki Yagi Konoshima Chemical Co.,Ltd. Takeshi Shigeta and Takayuki Ito Baikowski Japan Co.,Ltd.

1.Introduction 2.Basic Properties Emitting Spectrum Transmission rate -ray spectrum & light yield Decay time Uniformity & intrinsic BGD Response for -particles ( / ratio) Evaluating with APD 3.Summary

Inorganic Scintillators Single crystals have played a major role, so far. Difficulty in crystallizing Weakness of a mechanical strength Late production and high cost Studies in last year Chochralsky method Few materials exist for useful scintillators. e.g. NaI,CsI,GSO,BGO If we use poly-crystals, we may overcome these problems. We demand large and strong scintillators for the space use. 2003.3 The Physical Society of Japan Annual Spring Meeting, 2003.9 The Physical Society of Japan Annual Autumn Meeting Kasama 2003, Master thesis Cooperated by Konoshima Chemical and Baikowski Japan Microscope image of poly crystal presented by Konoshima Chemical Inc Ce:YAG (Y 3 Al 5 O 12, 4.57g/cm 3 ) We evaluated basic properties. 20 nm Poly Ce0.5% t 2.4mm Single t 40 m Poly Ce0.8% t 0.8mm Grain 5 m Crystal boundary layer

Emitting spectrum of YAG Wave length (nm) We investigated the emitting spectrum to choose the suited detector. Self-absorption : corrected Sensitivity of the PMT : un-corrected Peak emission wavelength is ~540nm. Quantum efficiency (%) / Emission strength Exiting wavelength 450nm PD NaI:415nm GSO:440nm BGO:480nm CsI:540nm PD is more suited for poly-yag than PMTs. PMT YAG Ce:0.5% :544nm YAG Ce:0.8% :540nm YAG Single :528nm APD(Avalanche Photodiode) Hamamatsu S8664-55 5 5 5 YAG(Ce:0.5%) (see poster 16 yanagida et al.) Miniaturizing a measuring system. Future space use.

Transparency Transparency Defect level :270nm Ce:460nm Ce:230nm Ce:340nm YAG:BandGap Wave length (nm) Ce:0.5% Ce:0.8% Single No particular absorption exists for a poly-crystal. Absorption band properties are same as single one. Few lattice defects exists. Little influence by selfabsorption.

γ-ray spectrum We used a PMT (Hamamatsu R6231) to investigate the -ray spectrum. Photoelectron absorption peak 137 Cs 662keV Temperature dependence of light yield ( 137 Cs 662 kev ) Poly 0.5 Single CsI (x 0.1) E 7.2% 20 Resolution is ~ 7.2% @ 662keV. Light yield : poly-yag/gso 70% For poly-crystal, it has low dependence of the temperature. Light yield to energy ratio is constant up to 1275 kev.

Decay time Decay time measurement Method : delayed coincidence method Pulse shape discrimination application Influencing to dead time Red : 0.5% Poly Green : Single Black : CsI Poly : 86 & ~1000 (ns) Two components exist for poly-yag. Faster than CsI scintillator. Details are in poster 15 Takahashi et al.

Uniformity for poly crystal We used Pb collimator =2mm). Intrinsic Backgrounds 3mm 17mm thickness ~ 2.4mm 241 Am:59.5keV Set up Data Spectrum 5 colors 5 points Peak CH: <0.5% consistent Stopping power: <5% consistent Uniformity has been confirmed. 1 10-5 count/sec/kev/cm 3. No particular natural RI contamination exists. It is applicable for low BGD measurement.

Response for particles / ratio The response for particles Assuming a space environment / ratio The possibility of a low BGD. Method: Using 241 Am, we irradiated particle 5.5 MeV and -ray 137 Cs. Energy spectrum / ratio -ray energy on the spectrum particle energy :59.5keV :662keV :5.5MeV :59.5keV :5.5MeV :662keV cf. / ratio GSO:0.20 BGO:0.21 Poly-YAG 0.5% / ratio 0.19 Single YAG / ratio 0.32 Poly crystal has a low efficiency to translate particle into a scintillation light.

Wavelength (nm) 137 Cs (662keV) YAG 5 5 5 spectrum 20 counts Evaluating poly-yag with an APD Quantum efficiency ~ 80% @ 540 nm ( the peak emission wavelength of YAG) APD : Internal gain is ~ 50 times. Quantum efficiancy 30min integration PMT APD MCA channel Poly YAG : 0.5% 662keV peak FWHM=6.3% (APD) Energy resolution is expected to be improved. Evaluation of results APD We compared YAG with other famous scintillators CsI (3mm 3 3) GSO (5 5 5) BGO (6 6 4) Poly-YAG (5 5 5) Cf. APD (5 5) See p16 yanagida et al. YAG showed a good performance compared with CsI.

Summary (Properties of poly-ce:yag) properties results Comparing with single remarks Light yield YAG/GSO 70% Little temperature dependence Energy resolution 7% 662keV Comparative with HXD- GSO Linearity residuals 1% Transparency No particular absorption Few lattice defects Grain size? Emitting spectrum peak 540 nm Shifting to longer Good for PD or APD (Yanagida et al.) Decay time 90 nsec& 1000 nsec Takahashi et al. Response for the charged particles Uniformity Stopping power Intrinsic BGDs / : 0.19 light yield 0.5 stopping power 5% Consistent with the theorem value. smaller Decay time : same with different 1 10-5 count/sec/kev/cm 3 GSO:0.20 / BGO:0.21 No longer component in single crystal. No particular RI component