Readout of LYSO using a new silicon photodetector for positron emission tomography

Similar documents
Charge collection in PET detectors

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

Gamma ray coincidence and angular correlation

Nuclear Instruments and Methods in Physics Research A

A scintillation dual-detector system featuring active Compton suppression

Recent Advances of Planar Silicon APD Technology

CHIPP Plenary Meeting University of Geneva, June 12, 2008 W. Lustermann on behalf of the AX PET Collaboration

Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

Investigation of Position Sensitive Avalanche Photodiodes for a New High Resolution PET Detector Design

Development of a High Precision Axial 3-D PET for Brain Imaging

Positron Emission Tomography

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

arxiv: v2 [physics.ins-det] 8 Feb 2013

Key words: avalanche photodiode, soft X-ray detector, scintillation γ-ray detector, imaging device PACS: 07.85;95.55.A;85.60.D

Stand-off Nuclear Radiation Detection

Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data

Semiconductor X-Ray Detectors. Tobias Eggert Ketek GmbH

Silicon Drift Detectors for gamma-ray detection: 15 years of research (and collaboration between Politecnico and INAF-Milano)

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

Compton Camera. Compton Camera

Scintillation Detectors

GAMMA RAY SPECTROSCOPY

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

X-ray spectrometry with Peltier-cooled large area avalanche photodiodes

Application of Nuclear Physics

A monolithic array of silicon drift detectors coupled to a single scintillator for γ-ray imaging with sub-millimeter position resolution

Geant4 simulation of SOI microdosimetry for radiation protection in space and aviation environments

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

Large Area Avalanche Photodiodes in X-rays and scintillation detection

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Design of a Lanthanum Bromide Detector for TOF PET

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Light yield non-proportionality and energy resolution of Lu 1.95 Y 0.05 SiO 5 :Ce and Lu 2 SiO 5 :Ce scintillation crystals

Sample Spectroscopy System Hardware

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

LET dependence of the charge collection efficiency of silicon microdosimeters

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Gamma and X-Ray Detection

DEVELOPMENT OF A NEW SILICON BASED DETECTOR MODULE FOR PET

Advances in PET technology

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Alpha-particle Stopping Powers in Air and Argon

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

Scintillators 1. YEAR, I. CYCLE. AUTHOR: BPhys. Manja Ščetinec ADVISOR/MENTOR: Prof. Boštjan Golob

Gamma Spectroscopy. References: Objectives:

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

Scintillators: new ways to fast emission

Introduction to Radiation Monitoring

1 of :32

Lecture 5: Tomographic nuclear systems: SPECT

Chapter 4 Scintillation Detectors

Alpha particle scintillation detector based on micro pixel avalanche photodiode and LYSO crystal

Factors Affecting Detector Performance Goals and Alternative Photo-detectors

First Results and Realization Status of a Proton Computed Radiography Device

Development of High-Z Semiconductor Detectors and Their Applications to X-ray/gamma-ray Astronomy

Analysis of γ spectrum

THE spectroscopic performance of large volume CdZnTe

Maximum-Likelihood Deconvolution in the Spatial and Spatial-Energy Domain for Events With Any Number of Interactions

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE

Application Note. The Continuous Air Monitoring (CAM) PIPS Detector Properties and Applications

Timing and Energy Response of Six Prototype Scintillators

New trends in CdTe detectors for X and γ-ray applications

A new timing model for calculating the intrinsic timing resolution of a scintillator detector

Inorganic Scintillators

Practical 1P4 Energy Levels and Band Gaps

Single Photon detectors

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Recent advances and future perspectives of gamma imagers for scintimammography

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

Performance of a Si PIN photodiode at low temperatures and in high magnetic fields

Quality Assurance. Purity control. Polycrystalline Ingots

LEC E T C U T R U E R E 17 -Photodetectors

Mayneord-Phillips Summer School St Edmund Hall, University of Oxford July Proton decays to n, e +, ν

NUCL 3000/5030 Laboratory 2 Fall 2013

Ultra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals

Keywords: mechanical property, polymer optical fibre, radiation, transmission.

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

A gas-filled calorimeter for high intensity beam environments

PHOTODETECTORS AND SILICON PHOTO MULTIPLIER

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Review of Semiconductor Drift Detectors

A Study On Radioactive Source Imaging By Using A Pixelated CdTe Radiation Detector

CCD readout of GEM-based neutron detectors

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

Chem 481 Lecture Material 3/20/09

PET scan simulation. Meysam Dadgar. UMSU, Iran. IFMP, Elbasan, Fig 1: PET camera simulation in gate by cylindrical phantom

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

Transcription:

University of Wollongong Research Online Faculty of Engineering - Papers (Archive) Faculty of Engineering and Information Sciences 23 Readout of LYSO using a new silicon photodetector for positron emission tomography M. L. Lerch University of Wollongong, mlerch@uow.edu.au R. Ward University of Wollongong Philip E. Simmonds University of Wollongong, simmonds@uow.edu.au V. L. Perevertailo SPA-BIT "Detector", Kiev, Ukraine S. R. Meikle Royal Prince Alfred Hospital, Sydney See next page for additional authors http://ro.uow.edu.au/engpapers/49 Publication Details This article was originally published as: Lerch, MLF, Ward, R, Simmonds, PE et al, Readout of LYSO using a new silicon photodetector for positron emission tomography, IEEE Nuclear Science Symposium, 19-25 October 23, vol 2, 148-1412. Copyright IEEE 23. Research Online is the open access institutional repository for the University of Wollongong. For further information contact the UOW Library: research-pubs@uow.edu.au

Authors M. L. Lerch, R. Ward, Philip E. Simmonds, V. L. Perevertailo, S. R. Meikle, G. N. Taylor, and Anatoly B. Rosenfeld This conference paper is available at Research Online: http://ro.uow.edu.au/engpapers/49

Readout of LYSO Using a New Silicon Photodetector for Positron Emission Tomography Michael L.F. Lerch, Member, IEEE, Robert Ward Student Member, IEEE, Phillip E. Simmonds, Vladimir L. Pervertailo, Steven R. Meikle, Geoffery N. Taylor and Anatoly B. Rosenfeld, Senior Member, IEEE Abstract--. This article focuses on the characterisation of three versions of a custom designed silicon photodetector using nuclear spectroscopy techniques. Room temperature gamma ray spectroscopy experiments have been performed using an LYSO excited by 137 Cs and 22 Na sources and read out by the new photodiodes. We have measured an energy resolution of 13.1% FWHM for the 511 kev gamma rays from a 22 Na source and 11.2% FWHM for the 662 kev gamma rays from a 137 Cs source. This is one of the best ever-reported energy resolutions for a lutetium based scintillator crystal read out by a silicon photodetector. I. INTRODUCTION urrent commercial PET scanners are general purpose C devices which are designed to support a wide range of clinical applications. These generally require a scanner with reasonably large detector ring diameter ( 8 cm) and the ability to image the whole body in incremental steps. Recently, new applications of PET have emerged which place different demands on PET instrumentation, requiring high spatial resolution and sensitivity, in particular for imaging small volumes. Such applications include small animal imaging, breast cancer imaging and high resolution brain imaging. With these emerging applications, a large ring diameter is not only not required but also limits the performance that can be achieved when imaging small volumes. Manuscript received October 7, 23. This work was supported in part by the Australian National Health and Medical Research Council under Grant No. 162722, the Australian Institute for Nuclear Science and Engineering under grant number 884 and Insight Oceania Pty Ltd., Australia M.L.F. Lerch (email mlerch@uow.edu.au), R. Ward, P.E. Simmonds A.B. Rosenfeld are with the Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2522, Australia, Ph. +61 2 42214954. V.L.Pervertailo is with SPA-BIT, Kiev, Ukraine S.R. Meikle is with the PET and Nuclear Medicine Department, Royal Prince Alfred Hospital, Sydney, NSW, Australia G.N. Taylor is with the High Energy Physics Department, University of Melbourne, Melbourne, Vic, Australia Significant research has been undertaken in the development of read out schemes of scintillator crystal configurations in an attempt to improve the spatial resolution of PET scanners [1,2]. We are developing a new Positron Emission Tomography (PET) detection module with depth of interaction capability. Pixilated scintillation crystals read out by silicon 8x8 photodiode arrays form the basis of the new module. The new photodiode arrays were designed by the Centre for Medical Radiation Physics and produced by SPA Detector, Ukraine. Silicon photodiodes represent the relatively cheap and robust end of the silicon based photodetector (PD) market. Improvement in the photodiode quantum efficiency at wavelengths around 42 nm (the peak emission wavelength of LSO), whist maintaining good photogenerated charge collection times, represents one of the biggest challenges in the photodiode design. We have designed a silicon PD to improve the PD quantum efficiency near the emission wavelength of LSO. This article concentrates on comparison of the nuclear spectroscopic performance of the new PDs. In particular we are interested in measuring any quantitative improvement of the scintillation light collection efficiency of the diodes to see if it correlates with the measured improvement in the quantum efficiency. II. DETECTORS AND METHODS A. Detectors The photodiodes are of a planar design consisting of a 3x3 mm 2 active area and are 3 µm thick. The detectors were produced by SPA-BIT Detector, Ukraine on high resistivity n- Si (Resistivity 5 kωcm). Three versions of the diode were produced: SPAD1, SPAD2 and SPAD3. SPAD 2 and 3 are both structurally similar to SPAD1. However, SPAD2 includes p+ strips at the surface of the p- layer aimed at enhancing the charge collection time as shown in Fig. 1. SPAD3 includes an additional antireflective layer to improve photon detection near the 43 nm (peak emission wavelength of the LYSO scintillator)[3]. -783-8257-9/4/$2. 24 IEEE. 148

The LYSO scintillator crystals have an emission spectrum that nominally peaks at 43 nm [4]. The absorption length of light with a wavelength of 43 nm is.1-.2 µm in silicon. In order to improve the sensitivity of the new photodiodes at wavelengths in the region of 4nm we are using an (boron) ion implantation technique to produce the p - -layer that is optically coupled to the scintillator crystal. This technique allows the resulting electric field to extend very close to the p - active surface, which has the dimensions of 3x3 mm 2 for each pixel element in our array, when the PD is under bias while still maintaining the potential across the p - surface. In effect we are able to improve the sensitivity of the PD in the blue spectral region, by reducing the effect of Auger recombination, while maintaining good charge collection properties to ensure fast timing signals for coincident detection techniques. p - -layer SiO 2 (.1 µm ) SiO 2 (.5 µm ) Al passivation layer ( 1. µm ) C. Spectroscopy Experiments For gamma and X-ray spectroscopy experiments the spectroscopy readout arrangement comprised of an AMPTEK A25 preamplifier and a Canberra 221, spectroscopy amplifier. A PC, using software supplied with the MCA, collected the data via an AMPTEK TM 8A MCA. D. Scintillator Light Collection Efficiency The complicated nature of the optical transparent layers forming the entrance window of the PD leads to a complicated quantum efficiency (QE) curve as a function of incident optical photon angle (measured from the normal to the PD surface) [3]. The QE also varies with wavelength [3]. In order to compare one the gamma ray spectroscopy performance indicators of the different PD designs we have the SCLICE. SLICE is the scintillator light collection efficiency and is simply the deduced number of photons detected by the PD divided by the estimated absolute number of optical photons emitted within the scintillator per gamma ray event (~13,3 photons per 511 kev event for our LYSO). We have assumed here that each optical photon detected produces one electron hole pair in the PD. For SLICE deductions direct X-ray spectroscopy (no scintillator crystal attached) data is used and was obtained under identical experimental conditions. n-layer n + -layer p - -layer SiO 2 (.1 µm ) Fig. 1(a) SiO 2 (.5 µm ) Al p + -strips Al-layer passivation layer ( 1. µm ) III. RESULTS AND DISCUSSION A. Quantum Efficiency Fig. 2 shows the external quantum efficiency (QE) of the SPAD3 relative to SPAD1 over the wavelength range of 38 nm to 6 nm. The experimental method used to obtain this data is outlined in ref. [5]. The quantum efficiency of the SPAD3 is also shown on the same graph. The absolute responses were measured carefully under the same experimental conditions. 2 1. n-layer n + Al-layer -layer Fig. 1(b) Fig. 1 Schematic cut-away view of SPAD1 and SPAD2. The two designs differ in that one has a uniform p - layer at the surface (Fig. 1a) and the other has p + strips embedded in the p - layer (Fig. 1b). B. Scintillators The LYSO scintillator material was purchased from Crystal Photonics Inc.(CPI), Sanford, Florida, USA. The material was subsequently cut into 3x3x3 mm 3 cubes and polished and the absolute light output determined by A&D Precision Co., Newton, MA, USA. The absolute light output was deduced to be ~26 photons/kev, which is 65% of that of NaI (~4 photons/kev). Relative quantum efficiency 1.6 1.2.8.4 35 45 55 Wavelength (nm) Figure 2. Relative quantum efficiency (QE) of SPAD3 to SPAD1 together with the external QE of SPAD3..8.6.4.2. Quantum efficiency -783-8257-9/4/$2. 24 IEEE. 149

The data indicates that the measured relative response and deduced quantum of SPAD3 is significantly enhanced compared to SPAD1 over the blue/violet spectral region. The enhancement in the blue/violet region reaches a maximum of 1.8x at 45 nm. The internal quantum efficiency of these diodes has also been measured by us and is the same [3]. The deduced quantum efficiency for SPAD3 shown in Fig. 2 peaks at 45 nm where it is 81%. Across several photodiodes the peak wavelength varied by ± 15 nm and the peak quantum efficiency varied by ± 5%. This result is quite significant in that it indicates that SPAD3 is performing to its design specifications and hence is well suited for use with the LYSO scintillator whose emission wavelength peaks in the blue/violet spectral region. B. Gamma Ray Spectroscopy In gamma ray spectroscopy experiments the SPAD PD was optically coupled to a 3x3x3mm 3 LYSO crystal. The crystal has the same dimensions as that to be used in our detector module that incorporates pixilated crystals. The best-measured energy resolution was 13.1% FWHM for the 511 kev gamma rays and 11.2% FWHM for the 662 kev gamma rays from the 22 Na and 137 Cs source respectively. This result is shown in Fig 3 and was achieved using the SPAD3 PD, biased at 5V, to readout the painted LYSO scintillator, with a shaping time of.5 µs. Also shown in Fig 3 is the contribution to the FWHM from the readout electronics and PD system. The measured 8.2 % is equivalent to ~2e - rms. A variation in the energy resolution of ± 1% was observed by reading out the same LYSO crystal with several copies of the SPAD3 PD made from different parts of the wafer also used to make the silicon 8x8 arrays in the PET module. ADC Counts 3 25 2 15 1 5 FWHM = 8.2% FWHM = 13.1% SPAD3 + LYSO Bias 5 V.5 µs shaping time FWHM = 11.2% Cs-137 Series2 Na-22 Series1 Pulser 2 4 6 8 1 12 14 Figure 3. Pulse height spectrum of 22 Na and 137 Cs. Table 1 shows the experimentally measured energy resolution (T = 298 K) as a function of shaping time using the SPAD 3 photodetector at 5 V bias to read out the 3x3x3 mm 3 painted LYSO scintillator crystal excited by a 22 Na source. The excellent energy resolution measured at short shaping times indicates that the PD can operate well under high count rate conditions if necessary, which is important in PET. Shaping Time (µs) E/E (SPAD3 + LYSO) 511 kev photopeak.1 17.8 %.25 13.4 %.5 13.1 % 1. 15. % Table 1 Energy resolution as a function of shaping time. Fig. 4 shows the room temperature (298 K) pulse height spectrum when the LYSO crystal is excited by a 22 Na and 137 Cs source and read out by SPAD1 (top), SPAD2 (middle) and SPAD3 (bottom) PD respectively. In these experiments a 1. µs shaping time was used. Fig. 4 shows the ADC channel on the X- axis, which is proportional to the signal pulse from each detector. In this case the qualitative differences between each readout method is clearly observable. A quantitative comparison of the readout methods related to each PD is given in Table 2. C. Scintillator Light Collection Efficiency Fig. 4 shows the ADC channel on the X-axis and energy on the X2-axis. In this case the relative improvement in the scintillator light collection efficiency (SLICE) for each version of the SPAD PD is clear as all experiments were performed under the same conditions. A quantitative estimate of the number of e-h pairs created by the optical scintillator photons detected by the PD can be obtained using a direct X-ray spectrum measured under the same operating and measuring conditions as shown in Fig. 5. The 511 kev photopeak occurs at the same channel as a 24.8 kev X-ray event directly detected in the PD. Therefore effectively 685±7 optical photons are detected by the PD per 511 kev event in the LYSO crystal. Given that for our LYSO we expect 13,3±65 photons per 511 kev event the SLICE in this case is 53 ±.4%. A summary of the SLICE for each PD is shown in Table 2. Table 2 shows that an 18% improvement is observed in the scintillation light collection efficiency between the SPAD1 and SPAD3 readout scheme. This improvement is very significant in the application of these PDs for PET but is far less than the increase in measured external quantum efficiency. In order to understand this observation one must take into account the angular dependence and wavelength dependence of the optical response in combination with the angular distribution of the -783-8257-9/4/$2. 24 IEEE. 141

optical photons incident on the PD surface. We are doing this work as part of a separate study [3]. Counts Counts 97 297 497 697 897 197 14 12 1 8 6 4 2 12 1 1 2 3 4 5 6 8 6 4 SPAD1 + LYSO 56 256 456 656 856 156 14 SPAD2 + LYSO scheme was less significant than expected. The reduction is due to the addition of p+ strips within the active layer of the SPAD2 PD effectively reducing the internal quantum efficiency of the PD. The p+ strips occupy approximately one third of the active area. The minor reduction in efficiency could be tolerated if a significant improvement in the timing properties of the PD is observed. This study is currently on going. ADC Counts 3 25 2 15 1 5 511 kev 22 kev 27 kev Bias 5 V.5 µs shaping time Series2 SPAD3 + I -125 direct Series1 SPAD3 + LYSO + Na-22 2 4 6 8 1 Fig. 5 Room temperature pulse height spectrum of an LYSO crystal excited by a 22 Na source and read out by SPAD3 overlayed with an 125 I spectrum directly detected in the same PD. All operating and measurement conditions are identical. 2 Counts 15 215 415 615 815 115 14 12 1 8 6 4 2 1 2 3 4 5 6 1 2 3 4 5 6 SPAD3 + LYSO Fig. 4 Room temperature (298 K) pulse height spectrum when the LYSO crystal is excited by a 22 Na and 137 Cs source and read out by SPAD1 (top), SPAD2 (middle) and SPAD3 (bottom) PD respectively. The small decrease of 3±.3% in the scintillation light collection efficiency between the SPAD1 and SPAD2 readout PD E/E (LYSO) Scintillator Light Collection 511 kev peak Efficiency (SLICE) SPAD1 15.1 % 58 optical photons detected or 43.6 ±.4% SPAD2 16.8 % 58 optical photons detected or 42.1 ±.4% SPAD3 13.1 % 58 optical photons detected or 53. ±.4% Table 2 Comparison of the measured energy resolution (shaping time of.5 µs) and scintillator light collection efficiency (SLICE) for SPAD 1, SPAD2 and SPAD3. IV. CONCLUSION We have characterised the custom designed silicon photodiodes using nuclear spectroscopic techniques that will be used in the development of a new detector module for positron emission tomography. The SPAD3 PDs have a measured quantum efficiency of 81% at 45 nm. We have measured an energy resolution of 13.1% FWHM for the 511 kev gamma rays from a 22 Na source. The new photodiodes are well suited for the -783-8257-9/4/$2. 24 IEEE. 1411

readout of scintillators whose emission wavelength peak in the blue/violet spectral region. V. REFERENCES [1] Pichler, B.J., Bernecker, F., Boning, G., Rafecas, M., Pimpl, W., Schwaiger, M., Lorenz, E., Ziegler, S.I., A 4x8 APD array, consisting of two monolithic silicon wafers, coupled to a 32- channel LSO matrix for high-resolution PET. IEEE Trans. Nucl. Sci., Vol. 48 (4), 1391 1396, 21 [2] Levin, C.S., Design of a high resolution and high sensitivity scintillation crystal array with nearly perfect light collection Presented at 21 IEEE NSS and MIC Conference, San Diego, USA [3] R.D. Ward, M.L.F. Lerch, P.E. Simmonds, G. Takacs, V. Perevertailo, and A.B. Rosenfeld, Angular dependence of response in a New Silicon Photodiode for use in PET presenting at IEEE NSS/MIC conference 23. [4] Saoudi, A., Pepin, C., Pepin, C., Houde, D., and Lecomte, R., Scintillation light emission studies of LSO scintillators, IEEE Trans. Nucl. Sci., Vol. 46 (6), 1925 1928, 1999 [5] M.L.F.Lerch, A.B.Rosenfeld, P.E. Simmonds, G.N.Taylor, S.R.Meikle, V.L. Perevertailo Spectral Characterization of blueenhanced silicon photodiode, IEEE Trans. on Nucl. Sci., NS-48, N-4, 122-1224, 21-783-8257-9/4/$2. 24 IEEE. 1412