Large Size LYSO Crystals for Future High Energy Physics Experiments

Similar documents
Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

IN the last decade, cerium doped silicate based heavy

LSO/LYSO Crystal Development Ren-yuan Zhu

Precision Crystal Calorimetry in High Energy Physics: Past, Present and Future

Calibration and Monitoring for Crystal Calorimetry

Precision Crystal Calorimetry in High Energy Physics

INORGANIC crystal scintillators are widely used in high

BSO Crystals for the HHCAL Detector Concept

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE

A Study on Radiation Damage in PWO-II Crystals

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Fast Crystal Scintillators for Future HEP Experiments

Measurement of Transmittance, Emission and Light Output for PWO Crystals

The Next Generation of Crystal Detectors

Crystal calorimeters in the next decade

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Crystals for the HHCAL Detector Concept Rihua Mao, Member, IEEE, Liyuan Zhang, Member, IEEE, and Ren-Yuan Zhu, Senior Member, IEEE

Inorganic Scintillators

REVIEW OF CRYSTAL CALORIMETERS

Radiation Induced Color Centers and Light Monitoring for Lead Tungstate Crystals

Scintillation Detectors

Forward Calorimetry Ideas

Introduction to scintillators

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

BECAUSE of its fast scintillation and low cost, undoped

THE main physics motivation for building the Compact

Crystal Technologies for LC

First Look on Radiation Induced Photocurrent in LYSO+SiPM Package

Development of a High Precision Axial 3-D PET for Brain Imaging

The CMS ECAL Laser Monitoring System

05 - Scintillation detectors

The BaBar CsI(Tl) Electromagnetic Calorimeter

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

SCINTILLATION DETECTORS AND PM TUBES

NEW TYPES OF LEAD TUNGSTATE CRYSTALS WITH HIGH LIGHT YIELD

2.5 Physics of the Universe, Astrophysics, Nuclear Planetology Dark Matter and Double Beta Decay Study Planetary Nuclear

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Applications of Cerium-Doped Gadolinium Silicate Gd 2 SiO 5 :Ce. Scintillator to Calorimeters in High Radiation Environment

Scintillators Definitions - 1!

Optical transmission radiation damage and recovery stimulation of DSB:Ce 3+ inorganic scintillation material

Energy Resolution of Scintillation Detectors New Observations

Ultra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET

Fast Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon PIN Diodes and APDs

Scintillation detectors

New Results from the DREAM project

The fast light of CsI(Na) crystals

Platinum resistance. also wirewound versions. eg

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

Design and production of Scintillation Detectors

Dual-Readout Calorimetry with a Mo-Doped PbWO4 Electromagnetic Section

Dual readout with tiles for calorimetry.

Characterization of the Lanthanum Chloride Scintillation Detector

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Timing resolution measurement of a 3 Lanthanum Bromide detector

Thick-wall, Liquid-Filled Quartz Capillaries for Scintillation and Wavelength Shifting Applications

Nuclear Instruments and Methods in Physics Research A

Fast inorganic scintillators - status and outlook -

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

Design of a Lanthanum Bromide Detector for TOF PET

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

Scintillation Detectors

Chapter 4 Scintillation Detectors

Scintillating Crystals and their Applications in Particle and Nuclear Physics November 17-18, 2003

New Scintillators for the Border Monitoring Equipment

The Scintillation properties of Pr 3+ doped and Pr 3+, Ce 3+

Precision Polarimetry at JLab, 6 GeV Era G. B. Franklin Carnegie Mellon University

Recent advances and future perspectives of gamma imagers for scintimammography

Il Calorimetro Elettromagnetico di CMS

Feasibility of a new polarized active detector for low-energy ν

Week 6: Ch. 8 Scintillation Counters

Scintillators. Detectors for Particle Physics Thomas Bergauer Institute of High Energy Physics, Vienna, Austria

A new scintillator detector for nuclear physics experiments: the CLYC scintillator

Ultrafast Inorganic Scintillators for Gigahertz Hard X-Ray Imaging

Application of Nuclear Physics

CHIPP Plenary Meeting University of Geneva, June 12, 2008 W. Lustermann on behalf of the AX PET Collaboration

Time Structure in Dual Readout Calorimeters. Michele Cascella (UCL) for the RD52 Collaboration 1

Charge collection in PET detectors

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

OPPORTUNITY TO JOIN IEEE AND NPSS

A new timing model for calculating the intrinsic timing resolution of a scintillator detector

Scintillators General Characteristics

SCINTILLATORS AND WAVELENGTH SHIFTERS FOR THE DETECTION OF IONIZING RADIATION *

OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY. Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration

Study of pure CsI crystal coupling with APD. The University of Tokyo. Yi-Fan JIN

Recent Advances of Planar Silicon APD Technology

Scintillation Detectors Particle Detection via Luminescence

Scintillators for photon detection at at medium energies

CHAPTER 7 SUMMARY OF THE PRESENT WORK AND SUGGESTIONS FOR FUTURE WORK

PET. Technical aspects

Investigation of Ce-doped Gd2Si2O7 as a scintillator. Author(s) Kurashige, Kazuhisa; Ishibashi, Hiroyuki; Furusaka, Instructions for use

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

Timing and Energy Response of Six Prototype Scintillators

MCNP analysis and optimization of a double crystal phoswich detector

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Large Area Avalanche Photodiodes in X-rays and scintillation detection

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

José Antonio Briz Monago, M. Carmona-Gallardo and. M.J.G. Borge, A. Perea, O. Tengblad, M. Turrión

Transcription:

Large Size LYSO Crystals for Future High Energy Physics Experiments Jianming Chen, Liyuan Zhang, Ren-Yuan Zhu California Institute of Technology October 18, 2004 IEEE NSS04, Rome 1

Scintillating Crystals for HEP Crystal NaI(Tl) CsI(Tl) CsI BaF 2 BGO PbWO 4 LSO(Ce) GSO(Ce) Density (g/cm 3 ) 3.67 4.51 4.51 4.89 7.13 8.3 7.40 6.71 Melting Point (ºC) 651 621 621 1280 1050 1123 2050 1950 Radiation Length (cm) 2.59 1.85 1.85 2.06 1.12 0.9 1.14 1.37 Molière Radius (cm) 4.8 3.5 3.5 3.4 2.3 2.0 2.3 2.37 Interaction Length (cm) 41.4 37.0 37.0 29.9 21.8 18 21 22 Refractive Index a 1.85 1.79 1.95 1.50 2.15 2.2 1.82 1.85 Hygroscopicity Yes Slight Slight No No No No No Luminescence b (nm) (at peak) 410 560 420 310 300 220 480 560 420 420 440 Decay Time b (ns) 230 1300 35 630 300 50 40 60 6 0.9 10 Light Yield b,c (%) 100 45 5.6 21 13 0.1 75 30 2.3 2.7 0.6 d(ly)/dt b (%/ ºC) ~0 0.3-0.6-2 -1.6-1.9-0.3-0.1 ~0 Experiment Crystal Ball CLEO BaBar BELLE BES III KTeV TAPS (L*) (GEM) L3 BELLE PANDA? CMS ALICE PANDA? BTeV - - a. at peak of emission; b. up/low row: slow/fast component; c. measured by PMT of bi-alkali cathode. 2

A Strawman Detector for Super BaBar B. Wisniewski, Calor02, Pasadena Aiming at 10 36 /cm 2 /s luminosity for rare B decay Need fast detector with low noise LSO/LYSO? 3

LSO/LYSO Mass Production Capability CTI: LSO CPI: LYSO Saint-Gobain LYSO 4

2.5 x 2.5 x 20 cm LYSO Samples Saint-Gobain LYSO has perfect geometry & surface polishing CPI LYSO has chips at corners/surface because of lacking adequate polishing & treatment facilities for large size crystals CPI LYSO Saint-Gobain LYSO 5

Experiment Without any thermal treatment, all samples went through (1) initial measurement of optical and scintillation properties, (2) irradiations by γ ray for ~20 h each under 2, 100 and 9k rad/h, and (3) recovery. Properties measured: transmittance, emission and excitation spectra, light output, decay kinetics and light response uniformity, as well as their degradation under irradiation, and radiation induced phosphorescence. Because of serious phosphorescence, light output was measured two days after the ending of irradiation under 9 krad/h. 6

Transmittance Measurement HITACHI U-3210 UV/VIS spectrophotometer with a large sample compartment A simple way for looking absorption bands. No controversy. Beam 1 Precision of 0.3% can be reached. Beam 2 Theoretical limit of transmittance: NIM A333 (1993) 422 7

Photo Luminescence Measurement HITACHI F4500 Fluorescence Spectrophotometer Light Source (1), Gratings Efficiencies (2 & 3) & PMT QE (4) Red-Extended Hamamatsu R928 PMT(4): 185 to 900 nm 2 3 Sample Orientation 1 4 4 8

Comparison of 1.5 X 0 Cubic Samples LSO/LYSO samples have identical transmittance, emission & excitation spectra and a Cs peak FWHM resolution at 8 to 9% Part of LSO/LYSO emission is cut by their transmittance 9

1.5 X 0 Cubic Sample Light Output LSO/LYSO samples have compatible light output, which is a factor of 4 of BGO taking into account PMT response Decay time: 300 ns for BGO and 42 ns for LSO/LYSO 10

Long LYSO Excitation/Emission No longitudinal variation in emission & excitation 11

Long LYSO Transmittance CPI sample has a poor transmittance (surface polishing?) SG TT approaches theoretical limit, its LT shows an absorption band peaked at 580 nm: no effect on emission 12

Long LYSO Decay Kinetics Both samples have no longitudinal variation in decay kinetics CPI sample has lower light output because of poor surface 13

Long LYSO Light Response Uniformity LRU has a minor dependence on the end coupled to the PMT, indicating a slightly not uniform light yield along crystal 14

Long (2.5 x 2.5 x 20 cm) BGO Sample A slight negative slope for both end coupled to the PMT indicating a good longitudinal uniformity 15

Possible Origin of Non Uniformity C. Melcher: LO in LSO is a function of Ce concentration B. Chai: LO in LYSO is a function of atomic fraction of Yttrium 16

Caltech γ ray Irradiation Facilities Open 50 curie Co-60 provides 2 & 100 rad/h Closed 2,000 curie Cs-137 provides 9k rad/h with 5% uniformity 17

Transmittance under 2 rad/h An initial increase under 2 rad/h (need thermal annealing?) No further variation observed under 2 rad/h 18

Transmittance under 100 rad/h Some indication on initial decrease under 100 rad/h No further variation observed under 100 rad/h 19

Transmittance under 9 krad/h Small variation observed under 9 krad/h 20

LYSO Longitudinal Transmittance LT@430 nm Initial 2 rad/h 100 rad/h 9 krad/h CPI 63.2% 67.1% 64.9% 63.3% SG 77.1% 79.3% 78.5% 75.7% 21

LYSO Transmittance Damage LT @ 430 nm shows 6 and 3% increase under 2 rad/h, followed by 6 and 5% degradation under 9 krad/h for CPI and SG samples respectively 22

LYSO Excitation/Emission No variation in emission & excitation 23

Radiation Induced Phosphorescence Phosphorescence peaked at 430 nm was observed 24

Phosphorescence Decay Time Decay time constant: 2.5 to 3 h SG sample has a higher residual phosphorescence 25

Light Output Degradation LO may have some degradation after irradiation, which is to be confirmed by further measurement 26

Long LYSO Light Response Uniformity Small visible variation in light response uniformity LO degradation is to be confirmed by further measurement 27

Summary Ce doped LSO & LYSO crystals have identical emission, excitation and transmittance spectra. Their fast light output of 42 ns decay time is 4 times of BGO. Their absorption edge in transmittance affects light output. 2.5 x 2.5 x 20 cm LYSO samples from CPI and Saint- Gobain have good longitudinal uniformity. Their light response uniformity may be slightly affected by the distribution of the Ce concentration. One of the main consequence of radiation damage in LYSO under γ ray irradiation is radiation induced phosphorescence, which has a time constant of 2.5 to 3 h. Radiation effect on transmittance, emission and excitation spectra and light output is small as compared to other commonly used crystals. Detailed study with solid state (PD or APD) readout in under way. With existing mass production capabilities, LSO & LYSO crystals are a good candidate for future crystal calorimeter in high energy physics. 28