ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Similar documents
Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Measurement of high energy gamma rays with large volume LaBr 3 :Ce scintillators

Design of a Lanthanum Bromide Detector for TOF PET

New Scintillators for the Border Monitoring Equipment

Investigation of fast neutron spectroscopy capability of 7 Li and 6. Li enriched CLYC scintillator for nuclear physics experiments

arxiv: v1 [physics.ins-det] 29 Jun 2011

Timing and Energy Response of Six Prototype Scintillators

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

Timing resolution measurement of a 3 Lanthanum Bromide detector

Large volume LaBr 3 :Ce detectors and HECTOR +

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

Scintillation Products Technical Note

Enhanced α-γ Discrimination in Co-doped LaBr 3 :Ce

Characterization of the Lanthanum Chloride Scintillation Detector

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

DETECTORS. I. Charged Particle Detectors

arxiv: v1 [physics.ins-det] 16 May 2017

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Instrumentation and Physics Cases for EURISOL- DF, the next step towards EURISOL

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

AGATA preamplifier performance on large signals from a 241 Am+Be source. F. Zocca, A. Pullia, D. Bazzacco, G. Pascovici

The Use of Neutron Generators for the Detection of Illicit Materials in the Sea Transportation System

MCNP analysis and optimization of a double crystal phoswich detector

High-efficiency and fast-timing scintillators

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Response function and linearity for high energy γ-rays in large volume LaBr3:Ce detectors

Efficiency. Calculations for Selected Scintillators. > Detector Counting. Efficiency. > Photopeak Efficiency of Various Scintillation Materials

Preparatory experiments for cold-neutron induced fission studies at IKI

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

Special Nuclear Material Detection Studies With The SMANDRA Mobile System

DELAYED COINCIDENCE METHOD FOR PICOSECOND LIFETIME MEASUREMENTS

LAB 4: Gamma-ray coincidence spectrometry (2018)

Measurement and simulation of proton induced activation of LaBr 3 :Ce

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

Response function measurements of an NE102A organic scintillator using an 241 Am-Be source

A new scintillator detector for nuclear physics experiments: the CLYC scintillator

Gamma Spectroscopy. References: Objectives:

arxiv: v2 [physics.ins-det] 8 Feb 2013

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

Improved scintillation proportionality and energy resolution of LaBr 3 :Ce at 80K

Measurement of prompt fission γ-ray spectra in fast neutroninduced

national security, nonproliferation, defense, border security, and homeland security applications.

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

Application of positrons in materials research

LaBr 3 (Ce) detector and PMT tests at IPN Orsay

EEE4106Z Radiation Interactions & Detection

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

New Photonis XP20D0 photomultiplier for fast timing in nuclear medicine

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

OPPORTUNITY TO JOIN IEEE AND NPSS

Alpha-Energies of different sources with Multi Channel Analyzer

Radioactivity and Ionizing Radiation

Chapter 4 Scintillation Detectors

A Comparison between Channel Selections in Heavy Ion Reactions

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

GAMMA RAY SPECTROSCOPY

Precision neutron flux measurement with a neutron beam monitor

INORGANIC crystal scintillators are widely used in high

Identification and rejection of scattered neutrons in AGATA

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Investigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay

Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors

Investigation of Pygmy Dipole Resonance in neutron rich exotic nuclei

Non-proportional response and energy resolution of pure SrI 2 and SrI 2 :5%Eu scintillators

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Sample Spectroscopy System Hardware

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

Energy Resolution of LaBr 3 (Ce) Gamma-Ray spectrometer for Fusion Plasma Studies on JET

Scintillation Detector

SCINTILLATION DETECTORS AND PM TUBES

Compton Imaging with Coincidence Measurements for Treaty Verification Purposes

CCD readout of GEM-based neutron detectors

Development of new instrumentation for epithermal neutron scattering at very low angles

Characterization of the new scintillator Cs 2 LiYCl 6 :Ce 3+ *

Neutron Response of LaBr 3 :Ce and CsI:Na Phoswich Crystal Scintillators for PARIS

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

arxiv: v1 [physics.ins-det] 3 Feb 2011

Detection and measurement of gamma-radiation by gammaspectroscopy

The Advanced Gamma Ray Tracking Array AGATA

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

Monte-Carlo Simulation of Response Functions for Natural Gamma-Rays in LaBr 3 Detector System with Complex Borehole Configurations

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

Study of multi-nucleon transfer reactions with light nuclei

The SpecMAT project: An array of gamma-ray detectors around an active gas target

Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum

X ray Imaging Android [XIA]

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

RADIOACTIVITY IN THE AIR

Decay studies of 170,171 Au, Hg, and 176 Tl

Digital two-parametric processing of the output data from radiation detectors

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

Modern Physics Laboratory (Physics 6180/7180)

Transcription:

Nuclear Instruments and Methods in Physics Research A 62 (29) 52 524 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima Alpha gamma discrimination by pulse shape in LaBr 3 :Ce and LaCl 3 :Ce F.C.L. Crespi a,b, F. Camera a,b,, N. Blasi b, A. Bracco a,b, S. Brambilla b, B. Million b, R. Nicolini a,b, L. Pellegri a, S. Riboldi a,b, M. Sassi a,b, O. Wieland b, F. Quarati c, A. Owens c a Università di Milano, Dipartimento di Fisica, Via Celoria 16, 2133 Milano, Italy b INFN sez. of Milano Via Celoria 16, 2133 Milano, Italy c Advanced Studies and Technology Preparation Division (SCI-PA), ESA/ESTEC Keplerlaan 1, 221AZ Noordwijk, the Netherlands article info Article history: Received 18 December 28 Received in revised form 13 January 29 Accepted 18 January 29 Available online 3 February 29 Keywords: LaBr 3 scintillators LaCl 3 scintillators Lanthanum halide Gamma spectroscopy Brillance Gamma detectors Self-activity PID Alpha gamma discrimination Pulse Shape Analysis abstract The line-shape of the signals from LaBr 3 :Ce and LaCl 3 :Ce detectors coupled to PM tubes were studied. The possibility of discriminating the type of interacting radiation was investigated making use of Pulse Shape Analysis (PSA) techniques. The study was performed measuring the self-activity present in lanthanum halide crystals in coincidence with g-rays in a HPGe crystal. A small but significant difference between a- and g-induced signals was directly observed for both the crystals. Using a simple PSA algorithm, it was possible to emphasize the differences in the pulse shape of g-rays and a-particles. This resulted in a rather clear identification of these two types of radiations. & 29 Elsevier B.V. All rights reserved. 1. Introduction In the last few years, the lanthanum halide scintillators are attracting the scientific community in nuclear spectroscopy because of their almost ideal scintillation properties. Recent studies have shown that LaBr 3 :Ce material gives optimal energy resolution for scintillators (o3% at 662 kev), an excellent time resolution (E3 ps), good efficiency [1 7] and a negligible variation of light output within the temperature range 2 to +6 1C [8]. The LaBr 3 :Ce and LaCl 3 :Ce crystals are commercially available from Saint Gobain Crystals under the brand name BrilLanCe TM, in particular, LaCl 3 :Ce is named BrilLanCe35 and LaBr 3 :Ce is named BrilLanCe38. The availability of both LaBr 3 :Ce and LaCl 3 :Ce crystals (from now both addressed as BrilLanCe TM ) in volumes larger than 1 cc could make lanthanum halide scintillators a possible alternative to HPGe detectors for g-ray measurements. In fact, if compared with HPGe, these crystals provide an excellent trade-off between efficiency and energy resolution, with, in addition, subnanosecond timing [9]. Such properties can be extremely useful in Corresponding author at: Università di Milano, Dipartimento di Fisica, Via Celoria 16, 2133 Milano, Italy. E-mail address: camera@mi.infn.it (F. Camera). situations in which the measured spectra are not very complex or in which the Doppler broadening, due to the velocity of the emitting source, is comparable to the resolution of BrilLanCe TM detectors [1]. The sub-nanosecond time resolution, on the other hand, allows the measurement of Time of Flight with high resolution. This information is usually used for neutron g discrimination and for background rejection. The aforementioned situation can, for example, be found in specific in-beam measurements with fast exotic beams [1]. An aspect that is not yet fully investigated is the response, in terms of scintillation light, of BrilLanCe TM crystals to lightcharged particles. In fact, while there are several studies on the properties of these detectors, there is only one single research [11] on the pulse-shape discrimination capabilities of these scintillators. The work concentrated on the analysis of the pulse shapes for a-particles from 249 Cf and for g-rays from 232 U source. The work shows the feasibility of g a discrimination in LaCl 3 :Ce using the charge comparison methods but does not show any spectra corresponding to events selected using g and a interaction. The possibility to discriminate particles from g-rays is an important issue in g-spectroscopy or, more generally, in nuclear physics experiments. In this work we compare the line-shape of signals generated by a-particles and g-rays detected in both LaBr 3 :Ce and LaCl 3 :Ce scintillators. In addition, an algorithm to distinguish a-particles 168-92/$ - see front matter & 29 Elsevier B.V. All rights reserved. doi:1.116/j.nima.29.1.11

F.C.L. Crespi et al. / Nuclear Instruments and Methods in Physics Research A 62 (29) 52 524 521 from g-rays is applied to the data and the corresponding results are discussed. 25 2. The identification technique For the present study of g-rays and a-particles identification, use is made of the internal radioactivity which is providing, simultaneously, both radiation types. In fact, the natural radioactivity induced by the 227 Ac decay chain is always present inside BrilLanCe TM crystals. The employed technique is based on a coincidence measurement using a HPGe detector [12,13] together with a BrilLanCe TM crystal. The a-particles-induced signal has been identified searching for events with energy between 1.5 and 3. MeV in BrilLanCe TM crystals and, correspondingly, a g-ray (measured in HPGe detector), which is a discrete transition of a nucleus in the decay chain of 227 Ac. The set of signals produced by g-rays was selected searching for events that correspond to a single g-ray of natural background, which is scattered in one detector and fully absorbed in the second (the sum of the two energy releases is the energy of the transition). The adopted technique allows a perfect and unambiguous identification of the signals induced by low-energy a-particles and g-rays. In addition, the selected events, even though generated by different types of radiations, were those that have produced exactly the same amount of scintillation light (measured as total energy in the spectroscopic amplifier, see the following section). As 227 Ac is supposed to be uniformly distributed inside the BrilLanCe TM crystal, the method samples the scintillation properties of the whole crystal. It should be noted that by using a low-energy a-source, one would have sampled only the surface of the crystal, namely the region where the a-particles are fully stopped. 3. The measurement Two crystals were used for this study: a LaCl 3 :Ce crystal, cylindrically shaped, with a diameter of 4 and 6 length and a 1 1, cylindrically shaped LaBr 3 :Ce detector. The LaCl 3 :Ce internal activity (measured in the range.7 3 MeV) is 1.9 cts/s/cc (.4 cts/s/cc in the alpha region) while that of LaBr 3 :Ce is 4.4 cts/s/cc (.5 cts/s/cc in the alpha region). The PM tubes coupled to the crystals were Photonis XP354B2 (LaCl 3 :Ce) and XP26 (LaBr 3 :Ce) with standard voltage dividers. In both cases, the crystals were encapsulated and the PMT was attached to the glass window of the capsule. The energy resolution at the 662 kev line of 137 Cs was 4.2% for LaCl 3 :Ce and 3.2% for LaBr 3 :Ce. In the measurements, the BrilLanCe TM detectors were placed facing a HPGe detector (Tennelec CPVDS3-1195). Events which trigger both the HPGe and the BrilLanCe TM allowed the DAQ system to acquire the total deposited energy in both detectors and to sample their pulse line-shapes. The total deposited energy was extracted using a Tennelec Tc244 (for HPGe detector) and a Camberra 22 (for BrilLanCe TM ) spectroscopic amplifiers and a CAEN V879 ADC. The detector pulses were acquired using a 12 bit CAEN V1729 ADC VME board with a sampling frequency of 2 GHz in a KMAX environment [14]. A matrix of the events with signals in both HPGe (on the x-axis) and LaBr 3 :Ce (on the y-axis) is displayed in Fig. 1. The horizontal (vertical) lines in Fig. 1 correspond to g-rays that have deposited all their energy in HPGe (LaBr 3 :Ce) in coincidence with radiation in LaBr 3 :Ce (HPGe). The diagonal lines at 451, namely E HPGe +E BrilLanCe TM ¼ constant, are associated to single photons which enter in one detector and then scatter out and Energy_LaBr (kev) 2 15 1 5 2 4 6 8 1 12 14 16 Energy_HPGe (kev) Fig. 1. The matrix of coincidence events measured with the LaBr 3 :Ce (y-axis) and with the HPGe (x-axis) detectors. Amplitude (A.U.).14.12.1.8.6.4.2 2 4 15.% 1.% 5.%.% -5.% -1.% 2 4 6 Gamma Alpha are fully absorbed in the second detector. A similar matrix was obtained using the LaCl 3 :Ce crystal instead of LaBr 3 :Ce. Within the circular region in Fig. 1, some vertical lines are clearly visible. They are associated to events corresponding to alpha decays (measured in BrilLanCe TM detectors) followed by discrete g transitions (detected in HPGe). As discussed in the previous section, the pulses associated to these events identify unambiguous signals produced in BrilLan- Ce TM by a-particles. The events in the rectangular region of Fig. 1 identify the 2615 kev g-rays from 28 Tl, which have scattered in one detector and are fully absorbed in the other. They were used as signals for g-ray events. In Figs. 2 and 3 we present the comparison between the shape of the pulses measured for a-particles and g-rays with LaBr 3 :Ce and LaCl 3 :Ce detectors. In the inset the relative ratio calculated around the maximum of the signal is shown. The pulses shown in the figures are averages of several hundreds of pulses measured directly at the anode of the PMT all having the same energy as obtained with the Percent Difference 6 8 1 12 Fig. 2. The signal line-shapes measured for a-particles and g-rays in a LaBr 3 :Ce detector. Each pulse is the result of an average of E3 pulses with the same energy measured using the spectroscopic amplifier. In the inset the ratio between the difference of the two signals and the alpha one, calculated in the interval 6 ns, is displayed.

522 F.C.L. Crespi et al. / Nuclear Instruments and Methods in Physics Research A 62 (29) 52 524 Amplitude (A.U.).6.5.4.3.2 Percent Difference 8.% 6.% 4.% 2.%.% -2.% -4.% -6.% 2 6 1 14 Alpha 18.1 Gamma 4 8 12 16 2 24 Fig. 3. The signal line-shapes measured for a-particles and g-rays in a LaCl 3 :Ce detector. Each pulse is the result of an average of E15 pulses with the same energy measured using the spectroscopic amplifier. In the inset the ratio between the difference of the two signals and the alpha one, calculated in the interval 2 18 ns, is displayed. spectroscopic amplifier. No corrections for the bandwidth of the PMT or any kind of normalization of the pulses were applied. The difference between an alpha- and a gamma-induced event is of the order of 1% maximum. An interesting feature is the fact that while in LaBr 3 :Ce the signal generated by a-particles is slightly faster than the one generated by g-rays, in LaCl 3 :Ce exactly the opposite happens. 4. a c discrimination As already discussed in Ref. [11], the expected difference in line-shape between alpha- and gamma-induced events is very small. In fact, BrilLanCe TM crystals do not have different components within the scintillation light, like, for example, BaF 2, which responds in a very different way if g-rays or charged particles interact. However, by applying a simple algorithm, which uses a figure of merit I we can clearly show that a-particles and g-rays can be selected with reasonable efficiency (see Fig. 4). The applied algorithm is based on the fact that the difference between the pairs of signals reported in Figs. 2 and 3 is concentrated in an interval around the maximum. In the adopted procedure the figure of merit I is defined as tmax P trace½š i i¼t I ¼ min A (4.1) where t min and t max are, respectively, lower and upper boundaries of the interval in which the difference between the signals associated to alpha and gamma radiations is maximized (i.e. 1 3 ns for the case of LaBr 3 :Ce and 3 6 ns for LaCl 3 :Ce). The value of A in relation (4.1) is the integral of the input trace (i.e. trace[n], the signal sampled directly at the output of the PMT as described in Section 3) which is computed as A ¼ XtþN i¼t trace½iš (4.2) In this relation N indicates the number of samples per signal and t is the signal starting time. The value of t was obtained using the leading-edge method on normalized pulses. It is important to stress that a good time alignment of signals is an important issue in order to properly compare their shapes. Fig. 4. The I spectrum (see text) obtained applying the algorithm discussed in the text. In the bottom panel, which refers to LaCl 3 :Ce, the peak on the left corresponds to alpha events while the one on the right corresponds to g-ray events. Exactly the opposite happens in the top panel which refers to LaBr 3 :Ce. The arrows show I thr, namely the used threshold in I to select a-particles or g-rays. Alternatively, the value of A can be obtained directly using the energy value measured in the electronic chain with the spectroscopic amplifier. We have computed the I value distributions for two datasets of purely alpha events and purely gamma events. These datasets were selected imposing appropriate conditions in the matrix of coincidence events measured with the LaBr 3 :Ce (or LaCl 3 :Ce) and HPGe detectors (Fig. 1), using the identification technique described in Section 2. The resulting distributions are displayed in Fig. 4 (the two panels of the figure refer to the case of LaBr 3 :Ce and LaCl 3 :Ce, respectively); in both cases two well-separated peaks appear: one is associated to a-particles events the other to g-rays. The fact that in each case the distributions are well separated shows that a-particles and g-rays can be selected using the proposed algorithm, with reasonable efficiency. As shown in the two panels of Fig. 4 (for both LaBr 3 :Ce and LaCl 3 :Ce), I thr corresponds to the value of I for which the uncertainty in the alpha/gamma discrimination is maximum. The I thr value extracted in this way can then be used for discriminating alphas and gammas in any other independent measure (namely for a LaBr 3 :Ce detector if I 4I thr then the processed signal is

F.C.L. Crespi et al. / Nuclear Instruments and Methods in Physics Research A 62 (29) 52 524 523 associated to an alpha particle, otherwise to a gamma; just the opposite is done in the case of using a LaCl 3 :Ce detector). An event-by-event comparison between the measured I and the threshold value I thr placed between the two distributions allows a a g discrimination with a high level of accuracy. It is clear that the degree of accuracy of the a g discrimination depends on the value of I thr and on the relative ratio between the intensities of the a and g emissions. In the present case it was possible to identify E9% (in LaBr 3 :Ce) and E75% (in LaCl 3 :Ce) of the measured particles. The matrixes displayed in Fig. 5 show the region of Fig. 1 selected with the circle without any condition (top panel) on I, selecting g-rays (central panel) or a-particles (bottom panel). The plots clearly show that a good, although not perfect, identification 45 4 NO CONDITIONS 35 3 25 2 15 1 5 45 4 5 1 15 2 25 3 GAMMA GATED 35 3 25 2 15 1 5 45 4 5 1 15 2 25 3 ALPHA GATED 35 3 25 2 15 1 5 5 1 15 2 25 3 Fig. 5. A blow-up of the region selected by the circle in Fig. 1 when no condition on I is applied (top panel), selecting g-rays (I oi thr central panel) and selecting a-particles (I 4I thr bottom panel). Fig. 6. The internal radioactivity and natural background spectra measured with the LaBr 3 :Ce detector. The top panel spectrum shows the measurement in single with no condition on I (see text). Middle and bottom panels show the spectra obtained by placing alpha or gamma ray conditions on I through Pulse Shape Analysis.

524 F.C.L. Crespi et al. / Nuclear Instruments and Methods in Physics Research A 62 (29) 52 524 1 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 NO CONDITIONS 1 12 14 16 18 2 22 24 26 28 GAMMA GATED 1 12 14 16 18 2 22 24 26 28 1 ALPHA GATED 1 12 14 16 18 2 22 24 26 28 Fig. 7. The internal radioactivity and natural background spectra measured with the LaCl 3 :Ce detector. The top panel spectrum shows the measurement in single with no condition on I (see text). Middle and bottom panels show the spectra obtained by placing alpha or gamma ray conditions on I through Pulse Shape Analysis. of the nature of the interacting particle was achieved. Very similar results were obtained for the LaCl 3 :Ce detector although, as expected from Fig. 4, the a g discrimination is somewhat less selective. As a final check we have applied the algorithm to the pulses of LaBr 3 :Ce and LaCl 3 :Ce detectors measured in singles, namely without any coincidence condition. In Figs. 6 and 7 the energy spectra extracted from this dataset are displayed. The top panels show the internal radioactivity plus natural background spectra measured in singles with the BrilLanCe TM detectors. Both spectra show, between 1.5 and 2.8 MeV, the contribution due to the alpha decays from the 227 Ac chain. In the case of LaBr 3 :Ce detector the alpha activity is 1 times stronger than that of the LaCl 3 :Ce and the energy spectrum of the alpha part, if compared with that of Refs. [12,13], does not show the strong peak centred at 2.8 MeV. The peak is produced by the alpha decay of 215 Po (half-life 1.9 ms, E a ¼ 7386 kev). Such decay has a lifetime shorter than the length of the busy signal of the acquisition (3 ms). Consequently, every time 215 Po decayed, the acquisition was already busy processing the data from the mother isotope 219 Rn and, consequently, the event could not be acquired and processed. In the case of LaCl 3 :Ce detector, instead, the 2.8 MeV peak from the 215 Po alpha particle is substituted by the 2615 kev gamma line from the decay of 28 Tl, which is present in the natural background. This peak is very weak in LaBr 3 :Ce spectrum because of the small volume of the detector. The middle panel of Figs. 6 and 7 shows the spectra produced requiring the g-ray condition. In the LaCl 3 :Ce spectrum the 1765 and 2615 kev peaks are clearly visible together with the 2615 kev Compton shoulder while in LaBr 3 :Ce spectrum almost no counts remain. Finally, the bottom panels of the figures show the alpha - gated spectra. From the comparison between middle and bottom panels it is clear that the used algorithm was capable of achieving a rather good alpha gamma selection. 5. Conclusion In this study we have compared the signal shape produced by a-particles and g-rays in BrilLanCe TM LaBr 3 :Ce and LaCl 3 :Ce detectors. The comparisons have shown that, with the used crystals, a small difference is present and that, as the displayed plots clearly show, this is sufficient to allow a good identification of the nature of the interacting particles. A further and extremely interesting step in the same direction is the measurement of the pulse shapes induced by neutrons, protons and heavy ions. These studies widen the application fields of BrilLanCe TM detectors in both nuclear physics and its applications. References [1] C.M. Rosza, et al., Performance summary: BrilLanCe TM scintillators LaCl 3 and LaBr 3, Saint Gobain crystals, available at //www.detectors.saint-gobain. coms. [2] E.V.D. van Loef, et al., Nucl. Instr. and Meth. A 486 (22) 254. [3] P. Menge, et al., Nucl. Instr. and Meth. A 579 (27) 6. [4] J. Glodo, et al., IEEE Trans. Nucl. Sci. NS-52 (25) 185. [5] F. Quarati, et al., Nucl. Instr. and Meth. A 574 (27) 115. [6] W.W. Moses, Nucl. Instr. and Meth. A 487 (22) 123. [7] K.S. Shah, et al., IEEE Trans. Nucl. Sci. NS-51 (24) 2395. [8] M. Moszynski, et al., Nucl. Instr. and Meth. A 568 (26) 739. [9] M. Moszynski, et al., Nucl. Instr. and Meth. A 567 (26) 31. [1] D. Weisshaar, et al., Nucl. Instr. and Meth. A 594 (28) 56. [11] C. Hoel, et al., Nucl. Instr. and Meth. A 54 (25) 25. [12] R. Nicolini, et al., Nucl. Instr. and Meth. A 582 (27) 554. [13] B.D. Milbrath, et al., Nucl. Instr. and Meth. A 547 (25) 54. [14] S. Brambilla, et al., Sparrow Corporation Data Acquisition Conference and Workshop, 22 24 March 25, Daytona Beach, FL, 25.