Experiment 2: The Speed of Light

Similar documents
Introduction. Procedure. In this experiment, you'll use the interferometer to EQUIPMENT NEEDED: Lens 18mm FL. Component holder.

The Michelson Interferometer

Physics 476LW Advanced Physics Laboratory Michelson Interferometer

The Michelson Interferometer as a Device for Measuring the Wavelength of a Helium-Neon Laser

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

THE DIFFRACTION GRATING SPECTROMETER

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Measurments with Michelson interferometers

SCHIEBER TELESCOPES. Unique, High-Quality Telescopes

Experiment 8 Michelson Interferometer

Lab 11 Simple Harmonic Motion A study of the kind of motion that results from the force applied to an object by a spring

ABSTRACT. The following values for the wavelength of the sodium doublet lines were calculated:

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION

Experiment 6: Interferometers

Optical Bench. Polarization and Brewster s Angle

C A S S I N I TRACKER

Assignment 3 Due September 27, 2010

CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

C A S S I N I. MODEL : C EQ3 900mm X 135mm COSMO BRANDS INC.

Michelson Interferometer

Assembly Manual for the Brevard Astronomical Society 16 inch F4.5 Dobsonian Telescope Brevard Astronomical Society P.O. Box 1084 Cocoa, FL 32922

Newton s Second Law. Newton s Second Law of Motion describes the results of a net (non-zero) force F acting on a body of mass m.

THE ZEEMAN EFFECT v3 R. A. Schumacher, May 2017 B. B. Luokkala, January 2001

Obtain an optical "bench" setup (there should be three sliding mounts on the calibrated horizontal bar. The setup is shown in the diagram below.

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

Measuring the Universal Gravitational Constant, G

Optical Interferometry

Atomic Spectra. d sin θ = mλ (1)

Measurements in Optics for Civil Engineers

Interferometers. PART 1: Michelson Interferometer The Michelson interferometer is one of the most useful of all optical instru

Introduction to Optics

Lab 10 - Harmonic Motion and the Pendulum

Particle-Wave Duality and Which-Way Information

Michelson Interferometry and Measurement of the Sodium Doublet Splitting

This lab was adapted from Kwantlen University College s Determination of e/m lab.

IO3. Modul Optics. Diffraction

Michelson Interferometer

Protokoll. Grundpraktikum II - Optical Spectroscopy

Tutorials. 1. Autocollimator. Angle Dekkor. General

Exp. P-6 Blackbody Radiation

5 TH ERMAL GRADIENT INTERFEROMETRIC MEASUREMENT

Experiment objectives: measure the ratio of Planck s constant to the electron charge h/e using the photoelectric effect.

Michelson Interferometer. crucial role in Einstein s development of the Special Theory of Relativity.

Charge to Mass Ratio of The Electron

AccuAligning TM Polar Scope for SmartEQ TM Portable German Equatorial GOTO Mount. Installation and User Manual. Product #3130

Lab 10 Circular Motion and Centripetal Acceleration

Overview of Experiments for Magnetic Torque

Measuring Newton's Constant of Universal Gravitation using a Gravitational Torsion Balance

THE CAVENDISH EXPERIMENT Physics 258/259

Lab #13: Polarization

GRAVITATIONAL TORSION BALANCE

Charge to Mass Ratio of The Electron

PHY 192 Optical Activity Spring

Hooke s Law. Equipment. Introduction and Theory

How to use your astronomical telescope for the first time.

Experiment P28: Conservation of Linear and Angular Momentum (Smart Pulley)

CBRD30CP3 & BOWRD30CP INSTRUCTION MANUAL

The Michelson Interferometer and the He-Ne Laser Physics 2150 Experiment No. 3 University of Colorado

NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT. Physics 211 E&M and Quantum Physics Spring Lab #9: Diffraction Spectroscopy

Interferometer for Squareness measurement

Atomic Spectra HISTORY AND THEORY

Lasentec Product Group

The Spring-Mass Oscillator

Speed of Light in Air

THE HAVERFORD UNIVERSITY S STRAWBRIDGE OBSERVATORY S OF THE 16 MEADE. A quick guide to using the 16 Meade Schmidt-Cassegrain Telescope

Atomic and Nuclear Physics

arxiv: v1 [physics.optics] 6 Jul 2009

Double-Slit Interference

Experiment O-2. The Michelson Interferometer

Millikan Oil Drop Experiment

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

Experiment P13: Atwood's Machine (Smart Pulley)

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

Parametric down-conversion

product manual H-3220A Benkelman Beam

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

PHY222 Lab 8 - Magnetic Fields and Right Hand Rules Magnetic forces on wires, electron beams, coils; direction of magnetic field in a coil

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado

The Photoelectric E ect

Instruction Manual. Model #: (Reflector) Lit #: / 06-07

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

GERMAN TYPE EQUATORIAL MOUNT (FM 51/52 - FM 100/102 - FM150) USER MANUAL

8. The Michelson Interferometer

Lab 8: Ballistic Pendulum

h/e Apparatus h/e Apparatus Accessory Kit

3. Elastic Collision. 3.1 Introduction. 3.2 Theory. a) Kinetic Energy of a Rolling Ball

LC-4: Photoelectric Effect

Experiment #4 Nature of Light: Telescope and Microscope and Spectroscope

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Bureau International des Poids et Mesures. Rapport BIPM -89/1

General Physics I Lab (PHYS-2011) Experiment MECH-1: Projectile Motion

CASSINI CQR-120 OPERATING INSTRUCTIONS

PHY 123 Lab 4 - Conservation of Energy

Lab 10: Harmonic Motion and the Pendulum

Lesson Plan: Introduction to Quantum Mechanics via Wave Theory and the Photoelectric Effect

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE

Transcription:

Experiment 2: The Speed of Light Modern Physics Laboratory Department of Physics and Astronomy Austin Peay State University September 12, 2006 Abstract In this experiment you will determine the value of the speed of light using Foucault s rotating mirror method. 1 Introduction The velocity of light in free space is one of the most important and intriguing constants of nature. Whether the light comes from a laser on a desk top or from a star that is hurtling away at fantastic speeds, if you measure the velocity of the light, you measure the same constant value. In more precise terminology, the velocity of light is independent of the relative velocities of the light source and the observer. Furthermore, as Einstein first presented in his Special Theory of Relativity, the speed of light is critically important in some surprising ways. In particular: 1. The velocity of light establishes an upper limit to the velocity that may be imparted to any object. 2. Objects moving near the velocity of light follow a set of physical laws drastically different, not only from Newton s Laws, but from the basic assumptions of human intuition. With this in mind, it s not surprising that a great deal of time and effort has been invested in measuring the speed of light. Some of the most accurate measurements were made by Albert Michelson between 1926 and 1929. Michelson measured the velocity of light in air to be 2.99712 10 8 m/sec. From this result he deduced the velocity in free space to be 2.99796 10 8 m/sec. 2 A Qualitative Description In this experiment, you will use a method for measuring the speed of light that is basically the same as that developed by Foucault in 1862 and used by Michelson in the 1920s. A diagram of the experimental setup is shown in Figure 1. Adapted from Instruction Manual and Experiment Guide for PASCO Scientific Model OS-9261A, 62, and 63A Speed of Light Apparatus. 1

Experiment 2: The Speed of Light 2 Figure 1: Focault s method With all the equipment properly aligned and with the rotating mirror stationary, the optical path is as follows. The parallel beam of light from the laser is focused to a point image at point s by lens L 1. Lens L 2 is positioned so that the image point at s is reflected from the rotating mirror M R, and is focused onto the fixed, spherical mirror M F. M F reflects the light back along the same path to again focus the image at point s. In order that the reflected point image can be viewed through the microscope, a beam splitter is placed in the optical path, so a reflected image of the returning light is also formed at point s. Now, suppose M R is rotated slightly so that the reflected beam strikes M F at a different point. Because of the spherical shape of M F, the beam will still be reflected directly back toward M R. The return image of the source point will still be formed at points s and s. The only significant difference in rotating M R by a slight amount is that the point of reflection on M F changes. Now imagine that M R is rotating continuously at a very high speed. In this case, the return image of the source point will no longer be formed at points s and s. This is because, with M R rotating, a light pulse that travels from M R to M F and back finds M R at a different angle when it returns than when it was first reflected. By measuring the displacement of the image point caused by the rotation of M R, the velocity of light can be determined. 3 Equipment OS-9261 Complete Speed of Light Apparatus: SE-9367 0.5 mw He-Ne Laser OS-9263A High Speed Rotating Mirror Assembly OS-9103 One-Meter Optics Bench Fixed Mirror OS-9172 Laser Alignment Bench Measuring Microscope OS-9142 Optics Bench Couplers OS-9133 Lens (48 mm FL) OS-9135 Lens (252 mm FL) OS-9109 Calibrated Polarizers (2) OS-9107 Component Holders (3) OS-8514 Laser Adapter Kit Alignment Jigs (2)

Experiment 2: The Speed of Light 3 Figure 2: Equipment Alignment 4 Procedure Thoroughly read and understand the provided equipment manual Instruction Manual and Experiment Guide for PASCO Scientific Model OS-9261A, 62, and 63A Speed of Light Apparatus (hereafter referred to as the Manual) before beginning this experiment. Pay particular attention to the Equipment section, as several pieces are delicate and easily damaged. 4.1 Setup and Alignment IMPORTANT: Proper alignment is critical, not only for getting good results, but for getting any results at all. Please follow the detailed alignment procedure in the Setup and Alignment section of the Manual very carefully. Best results have been obtained by performing the experiment on the floor, and not using the laser alignment bench couplers (though you must be very careful not to bump the apparatus). Allow yourself at least two hours to set up the experiment the first time. Figure 2 shows the approximate positioning of the components with respect to the metric scale on the side of the Optics Bench. The exact placement of each component depends on the position of the Fixed Mirror and must be determined by following the steps of the alignment procedure. Below is a summary of the alignment procedure. 1. Align the laser so the laser beam strikes the center of M R (use the alignment jigs). 2. Adjust the rotational axis of M R so it is perpendicular to the beam (i.e. as M R rotates, there must be a position at which it reflects the laser beam directly back into the laser aperture). 3. Insert L 1 to focus the laser beam to a point. Adjust L 1 so the beam is still centered on M R. 4. Insert L 2 and adjust it so the beam is still centered on M R. 5. Place the Measuring Microscope in position and, again, be sure that the beam is still centered on M R.

Experiment 2: The Speed of Light 4 Figure 3: Stray interference patterns in microscope view. Figure 4: Stretched spot in microscope view. CAUTION: Do not look through the microscope until the polarizers have been placed between the laser and the beam splitter 6. Position M F at the chosen distance from M R (12 15 meters), so the reflected image from M R strikes the center of M F. 7. Adjust the position of L 2 to focus the beam to a point on M F. 8. Adjust M F so the beam is reflected directly back onto M R. 9. Insert the polarizers between the laser and the beam splitter. 10. Focus the microscope on the image point. 11. Remove polarizers. 4.2 Alignment Hints Once you have the microscope focused, it may still be difficult to obtain a good spot. There may be several other lights visible in the microscope besides the spot reflected from the fixed mirror as in Figure 3. The most common of these are stray interference patterns. These are caused by multiple reflections from the surfaces of the lenses, and may be ignored. If necessary, you may be able to eliminate them by angling the lenses 1 2. Stray Spots are most often caused by reflections off the window of the rotating mirror housing. To determine which spot is the one you must measure, block the beam path between the rotating mirror and the fixed mirror. The relevant spot will disappear. If the spot you need to measure is significantly off-center, you can move it by adjusting the angle of the beamsplitter. Another common problem is a spot that is stretched with no easily discernible maxima (Figure 4). Check first to make sure that this is the spot you need by blocking the beam path between the moving and fixed mirrors. If it is, then twist L 2 slightly until the image coalesces into a single spot.

Experiment 2: The Speed of Light 5 Figure 5: Microscope view with rotating mirror, M R on. Once the mirror begins to rotate, it is safe to look into the microscope without the polarizers. You will notice that your carefully aligned pattern has changed: now the entire field is covered with a random interference pattern, and there is a bright band down the center of the field (Figure 5). Ignore the interference pattern; there s nothing you can do about it anyway. The band is the image of the laser when, once each rotation, the mirror reflects it into the microscope beamsplitter. This is also unavoidable. Your actual spot will probably be just to one side of the bright band. You can check for it by blocking and unblocking the beam path between the rotating mirror and fixed mirror and watching to see what disappears. If you aligned everything perfectly, the spot will be hidden by the bright band; in this case, make sure that you have a spot when the rotating mirror is fixed and is reflecting the laser to the fixed mirror. If you do have the correct spot under stationary conditions, then misalign the fixed mirror very slightly (0.004 or less) around the horizontal axis. This will bring the actual spot out from under the bright band. 4.3 Measurment The speed of light measurement is made by rotating the mirror at high speeds and using the microscope and micrometer to measure the corresponding deflection of the image point. By rotating the mirror first in one direction, then in the opposite direction, the total beam deflection is doubled, thereby doubling the accuracy of the measurement. 1. With the apparatus aligned and the beam image in sharp focus (see the previous section), set the direction switch on the rotating mirror power supply to CW, and turn on the motor. If the image was not in sharp focus, adjust the microscope. You should also turn L 2 slightly askew (about 1 2 ) to improve the image. To get the best image you may need to adjust the microscope and L 2 several times. Let the motor warm up at about 600 revolutions/sec for at least 3 minutes. 2. Slowly increase the speed of rotation. Notice how the beam deflection increases.

Experiment 2: The Speed of Light 6 3. Use the ADJUST knob to bring the rotational speed up to about 1,000 revolutions/sec. Then push the MAX REV/SEC button and hold it down. When the rotation speed stabilizes, rotate the micrometer knob on the microscope to align the center of the beam image with the cross hair in the microscope that is perpendicular to the direction of deflection. Record the speed at which the motor is rotating, turn off the motor, and record the micrometer reading. NOTE: When reversing the direction of movement of the micrometer carriage, there will always be some movement of the micrometer knob before the carriage responds. Though this source of error is small, it must be eliminated. Just adjust the initial position of the micrometer stage so that you always turn the micrometer knob in the same direction as you adjust it. 4. Reverse the direction of the mirror rotation by switching the direction switch on the power supply to CCW. Allow the mirror to come to a complete stop before reversing the direction. Then repeat your measurement as in step 3. NOTES: When the mirror is rotated at 1,000 rev/sec or more, the image point will widen in the direction of displacement. Position the microscope cross-hair in the center of the resulting image. The micrometer on the Measuring Microscope is graduated in increments of 0.01 mm for the beam deflections. 5. The following equation is derived in the apparatus manual: where: c = 4AD2 ω (D + B) s (1) c = the speed of light ω = the rotational velocity of the rotating mirror (M R ) A = the distance between lens L 2 and lens L 1, minus the focal length of L 1 B = the distance between lens L 2 and the rotating mirror (M R ) D = the distance between the rotating mirror (M R ) and the fixed mirror (M F ) s = the displacement of the image point, as viewed through the microscope. ( s = s 1 s; where s is the position of the image point when the rotating mirror (M R ) is stationary, and s 1 is the position of the image point when the rotating mirror is rotating with angular velocity ω.) When adjusted to fit the parameters just measured, it becomes: c = 8πAD2 (f cw + f ccw ) (D + B) (s cw s ccw) (2) where f cw and f ccw are the CW and CCW mirror frequencies and s cw and s ccw are the CW and CCW micrometer readings, respectively.

Experiment 2: The Speed of Light 7 Use equation 2 to calculate c. MAKE SURE TO DETERMINE ERRORS FOR A, B,D, and the CW and CCW micrometer readings. We will assume the motor frequencies are exact. 6. Repeat your measurement and calculation of c at least 5 times (you need not realign the apparatus between measurements). 5 Questions You should ensure that your laboratory report addresses the following questions. 1. Did you encounter any alignment difficulties? Did you have to deviate from the procedure described here or in the Manual in any way? Did you have to employ any of the tips and hints outlined here ore in the Manual? 2. Explain in your own words the derivation of equation 1. Do not regurgitate the manual! 3. Following the rules for error propagation given in the handout, calculate the error for each of the values of c you obtained. 4. What is your average value, with uncertainty, of c? 5. Can the experimental error account for the differences between your value of c and the accepted value in air of 2.99702547 10 8 m/s? Discuss the accuracy of your measurement (see the Notes on Accuracy section of the Manual).