Thermal measurements using Scanning Thermal Microscopy (SThM) Micro and Nanoscale measurements

Similar documents
SUPPLEMENTARY NOTES Supplementary Note 1: Fabrication of Scanning Thermal Microscopy Probes

Supplementary Information. Characterization of nanoscale temperature fields during electromigration of nanowires

Thermal analog to AFM force-displacement measurements for nanoscale interfacial contact resistance

Nanoscale Heat Transfer at Contact Between a Hot Tip and a Substrate

Basic Laboratory. Materials Science and Engineering. Atomic Force Microscopy (AFM)

SCANNING THERMAL MICROSCOPY OF THERMOELECTRIC PULSED LASER DEPOSITED NANOSTRUCTURES

Homework Week 3: Nanoscale and macroscale characterization Thermoelectricity: From Atoms to Systems

Thermal conductivity calibration for hot wire based dc scanning thermal microscopy

Olivier Bourgeois Institut Néel

Instrumentation and Operation

Thermoelectricity: From Atoms to Systems

nano-ta: Nano Thermal Analysis

Simulation and Optimization of an In-plane Thermal Conductivity Measurement Structure for Silicon Nanostructures

Supplementary Material to Native-oxide limited cross-plane thermal transport in suspended silicon membranes revealed by scanning thermal microscopy

Crystalline Surfaces for Laser Metrology

Nanoelectronic Thermoelectric Energy Generation

Lecture 2. Introduction to semiconductors Structures and characteristics in semiconductors. Fabrication of semiconductor sensor

Thermal Transport in Graphene and other Two-Dimensional Systems. Li Shi. Department of Mechanical Engineering & Texas Materials Institute

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

Temperature Measurement of Microsystems by Scanning Thermal Microscopy

APPENDIX 1 DESCRIPTION OF HOT WIRE ANEMOMETER

Chapter 12. Nanometrology. Oxford University Press All rights reserved.

Experimental Study on Interfacial Thermal Transport of Multi-Walled Carbon Nanotube

Electro-Thermal Transport in Silicon and Carbon Nanotube Devices E. Pop, D. Mann, J. Rowlette, K. Goodson and H. Dai

Improving Micro-Raman/AFM Systems Imaging Using Negative-Stiffness Vibration Isolation

MSN551 LITHOGRAPHY II

CHARACTERIZATION of NANOMATERIALS KHP

SUPPLEMENTARY INFORMATION

b imaging by a double tip potential

Scanning Tunneling Microscopy

Radiative Heat Transfer at the Nanoscale. Pramod Reddy University of Michigan, Ann Arbor

MODELING OF JOULE HEATING AND THERMOELECTRIC TRANSPORT IN THIN FILM SILICON FOR SJEM MEASUREMENT YOUNGJOON KOH THESIS

SCANNING THERMAL MICROSCOPY METHODOLOGY FOR ACCURATE AND RELIABLE THERMAL MEASUREMENT HO HENG WAH A THESIS SUBMITTED

Other SPM Techniques. Scanning Probe Microscopy HT10

Resistance Thermometry based Picowatt-Resolution Heat-Flow Calorimeter

ADVERTIMENT. Lʼaccés als continguts dʼaquesta tesi queda condicionat a lʼacceptació de les condicions dʼús

Transient Through-Silicon Hotspot Imaging

MICRO-SCALE SHEET RESISTANCE MEASUREMENTS ON ULTRA SHALLOW JUNCTIONS

Scanning Probe Microscopy. Amanda MacMillan, Emmy Gebremichael, & John Shamblin Chem 243: Instrumental Analysis Dr. Robert Corn March 10, 2010

Graphene photodetectors with ultra-broadband and high responsivity at room temperature

On the Use of Hot-Film Sensors in the Investigation of Fluid Dynamic Phenomena in the Near-Wall Region

Scanning Probe Microscopy (SPM)

Supplementary Figure 1 a) Scheme of microfluidic device fabrication by photo and soft lithography,

Microscopy AND Microanalysis MICROSCOPY SOCIETY OF AMERICA 2006

Chapter 10. Nanometrology. Oxford University Press All rights reserved.

Lecture 2. Introduction to semiconductors Structures and characteristics in semiconductors

Lecture 4 Scanning Probe Microscopy (SPM)

Control of the fabrication process for the sensors of the CMS Silicon Strip Tracker. Anna Macchiolo. CMS Collaboration

Application of electrostatic force microscopy in nanosystem diagnostics

Heat transfer in ultrahigh vacuum scanning thermal microscopy

Uncertainty Workshop: Overview of uncertainty factors in HTGHPs

Sensors and Actuators Sensors Physics

Supplementary Figures

Challenges for Materials to Support Emerging Research Devices

Thermal characterization of Au-Si multilayer using 3- omega method

Introduction to Thermoelectric Materials and Devices

Scanning Probe Microscopy (SPM)

Part 1: MetalMetal Contacts Workfunction Differences Flat band (a) (Pt) = 5.36 ev Pt Vacuum Fermi level Electrons Mo Vacuum Fermi level Electrons (Mo)

Nanoscale Energy Transport and Conversion A Parallel Treatment of Electrons, Molecules, Phonons, and Photons

Atomic Force Microscopy (AFM) Part I

QUANTITATIVE NANOMETER-SCALE THERMAL METROLOGY USING SCANNING JOULE EXPANSION MICROSCOPY KYLE LANE GROSSE THESIS

MEMS Pirani type vacuum sensor with extended sensitivity range

Simulation and Analysis of an Integrated Device to Simultaneously Characterize Thermal and Thermoelectric Properties

Kavli Workshop for Journalists. June 13th, CNF Cleanroom Activities

Semiconductor Physics fall 2012 problems

Diamond in Nanoscale Biosensing

Structural and Mechanical Properties of Nanostructures

Quantitative Scanning Capacitance Spectroscopy on GaAs and InAs Quantum Dots

EE 527 MICROFABRICATION. Lecture 5 Tai-Chang Chen University of Washington

And Manipulation by Scanning Probe Microscope

Sensing, Computing, Actuating

COVER SHEET NOTE: This coversheet is intended for you to list your article title and author(s) name only this page will not print with your article.

Integrated measuring system for MEMS

STM: Scanning Tunneling Microscope

SCANNING-PROBE TECHNIQUES OR APPARATUS; APPLICATIONS OF SCANNING-PROBE TECHNIQUES, e.g. SCANNING PROBE MICROSCOPY [SPM]

Lecture 2. Introduction to semiconductors Structures and characteristics in semiconductors

Using a Mercury itc with thermocouples

Supplementary Figure 1 Characterization of the synthesized BP crystal (a) Optical microscopic image of bulk BP (scale bar: 100 μm).

Effect of phonon confinement on the heat dissipation in ridges

Appendix 1: List of symbols

PHY 481/581. Some classical/quantum physics for the nanometer length scale.

Supplementary Information for On-chip cooling by superlattice based thin-film thermoelectrics

Understanding Hot-Wire Anemometry

Improving nano-scale imaging of of intergrated micro-raman/afm systems using negativestiffness

Point mass approximation. Rigid beam mechanics. spring constant k N effective mass m e. Simple Harmonic Motion.. m e z = - k N z

Quantised Thermal Conductance

[ ] Sensors for Temperature Measurement, and Their Application 2L R 1 1 T 1 T 2

Nanoholes for leak metrology

AC Electrothermal Characterization of Doped-Si Heated Microcantilevers Using Frequency-Domain Finite Element Analysis

JARA FIT Ferienprakticum Nanoelektronik Experiment: Resonant tunneling in quantum structures

Current mechanisms Exam January 27, 2012

SUPPLEMENTARY INFORMATION

Nanomechanics Measurements and Standards at NIST

THERMAL CONDUCTIVITY IMAGING USING THE ATOMIC FORCE MICROSCOPE

Thermal Sensors and Actuators

CNPEM Laboratório de Ciência de Superfícies

Chapter 10: Steady Heat Conduction

Solid Surfaces, Interfaces and Thin Films

Spring Semester 2012 Final Exam

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Transcription:

Lecture 2: Measurements with contact in heat transfer: principles, implementation and pitfalls PART 2 Thermal measurements using Scanning Thermal Microscopy (SThM) Micro and Nanoscale measurements Séverine Gomès 1 Metti 6 Advanced School: Thermal Measurements and Inverse Techniques Biarritz, March 1-6, 2014

Content The technique Principles Probes Operating modes Approaches of the measurement Energetic balance Modelling Calibration Main current issues 2

Scanning thermal microscopy: SThM The technique General principles Cantilever and probes Operating modes Bilan

General principles SThM methods operate by : bringing a sharp temperature sensing tip in close proximity to the solid surface to be characterized. using the variation of the the tip temperature depending on the changes of the heat transfer between the tip and sample surface SThM = Scanning Probe Microscopy technique + Small probe used as thermal sensor 4

General principles AFM-based systems Observation of all kind of materials Enable to obtain : Force-distance curves Cantilever carrier not represented Surface topography with the control of sample-probe contact force 5

General principles AFM-based systems Observation of all kind of materials Enable to obtain : Force-distance curves Surface topography with the control of sample-probe contact force and indenpently: Thermal signal versus probe sample force&distance Thermal imaging and measurement according to the principle of thermal probe 6

Cantilevers and probes Since 1993, various thermal methods based on the use of different thermosensitive sensors or phenomena Classification according to the temperature-dependent mechanism used: Thermovoltage: - Tunneling thermometry and point contact method - Built-in thermal sensors: Thermocouple Schottky diode Change in electrical resistance: Built-in thermal sensors Fluorescence: Fluorescent nanocrystal glued at the end of a AFM tip Thermal expansion: - Bilame effect - Measurement of the dilatation of the sample surface induced by its internal or external heating 7

Cantilevers and probes Since 1993, various thermal methods based on the use of different thermosensitive sensors or phenomena Classification according to the temperature-dependent mechanism used: Thermovoltage: - Tunneling thermometry and point contact method - Built-in thermal sensors: Thermocouple Schottky diode Change in electrical resistance: Built-in thermal sensors Fluorescence: Fluorescent nanocrystal glued at the end of a AFM tip Thermal expansion: - Bilame effect - Measurement of the dilatation of the sample surface induced by its internal or external heating focus on thermovoltage-based and resistive methods. 8

Thermoelectrical voltage =g(t) Cantilevers and thermocouple probes Some examples Lateral spatial resolution < 50nm [Shi et al.2001, J Microelectromechanical Sys 10, 370] The miniaturization of the cantilever, the tip and the junction at the tip end could lead to a decrease of the probe thermal time constants and to an improvement of the spatial resolution. [Kim et al. 2008., Applied Physics Letters 93, 203115.] Au Cr thermocouple SThM probe. 9

Cantilevers and resistive probes Some examples Electrical resistance =g(t) [Dinwiddie et al. E, Thermal Conductivity, vol. 22, 1994] Wollaston cantilever with a resistive Pt/Rh 10% wire probe Section : 5 µm Length: 200 µm V shape - curvature radius : 15-20 µm Spatial resolution: micrometric [Kelvin Nanotechnology, Glasgow Univ.] Thin film Pd resistor located at the tip of a contact mode AFM probe Cantilever made of Silicon Nitride (Si 3 N 4 ). Tip radius lower than 100 nm. Spatial resolution < 80 nm 10

Operating modes All resistive metallic probes can be used in two modes At first order, electrical resistance of the probe resistive element at a temperature Tp : R p0 : electrical resistance of the resistive element at T 0 α : temperature coefficient of its electrical resistivity Passive Mode for thermometry very small current through the probe minimal Joule self-heating and enables the measurement of the electrical resistance. During a scan, heat flows from the hot sample to the probe and changes the electrical resistance R p of the probe Active Mode for thermophysical properties analysis larger electrical current through the probe significant Joule heating of probe Probe = heat source + thermal sensor Part of the Joule power flows into the sample, depending on its thermal properties. The probe temperature is monitored by measuring the probe voltage. This temperature can be related to the thermal conductivity of the sample. Under both modes, dc, ac or both measurements ac regime improved signal-to-noise ratio, since lock-in detection is possible. 11

SThM methods Enable : Thermal contrast imaging & measurement Temperature field (sample surface) when the tip comes in local equilibrium with the sample Temperature map of a MESFET (metal/semiconductor field-effect transistor) General principles Thermal conductivity contrast if the temperature change is determined for a known heat flux Majumdar et al. -1993 SThM image obtained at the level of the interface between irradiated and non-irradiated areas of meso-psi (85% porosity). S. Gomes et al. MicroelectronicsJournal 44 (2013) Spatial resolution depends on three main factors : Tip sharpness Thermal design of the probe Tip-sample heat transfer mechanisms (surrounding environment) 12

Scanning thermal microscopy: SThM SThM measurement approaches Thermometry in steady-state regime and passive mode Thermophysical measurement (active mode) Energy balance Modelling Calibration Bilan

Energy balance As in all thermal measurement method involving a sensor in contact or in proximity with the sample surface to be characterized, Analysis of the energy balance of the system: probe - sample surrounding environment required Probe used in passive mode and in contact with a hot sample 14

Thermal resistance network model Energy balance Thermometry in steady-state regime and passive mode As at larger scale, Q st generates an error! 15

Thermal resistance network model Energy balance Thermometry in steady-state regime and passive mode Q s-t = T s In the simple case of a sensitive element at the tip apex, which is the case for almost all the thermovoltage-based SThM probes (T t,c = T probe ), and no heat transfer between the cantilever and the sample surface, ( r + r ) th, s T probe th, c = ( T T )( r + r ) probe r a th, pe r th, pe th, cant. th, cant. Expression of the correction to be applied to the nominal measurement of the instrument T probe : δt = T s T probe = ( T T )( r r ) probe a r th, p th, s + th, c 16

Thermal resistance network model Energy balance Thermometry in steady-state regime and passive mode Q s-t = T s In the simple case of a sensitive element at the tip apex, which is the case for almost all the thermovoltage-based SThM probes (T t,c = T probe ), and no heat transfer between the cantilever and the sample surface, ( r + r ) th, s T probe th, c = ( T T )( r + r ) probe r a th, pe r th, pe th, cant. th, cant. Expression of the correction to be applied to the nominal measurement of the instrument T probe : δt = T s T probe = ( T T )( r r ) probe a r th, p th, s + th, c If the error δt is unknown, only the probe tempertaure can be measured 17

Energy balance Thermophysical measurement (active mode) Thermal resistance network model Heating of the sample by the probe operating in active mode (in dc or ac regimes) Q t,s written as a function of : the thermal power P used for the heating of the probe, the measured probe temperature T probe the thermal property to be determined,,,,,, 18

Energy balance Thermophysical measurement (active mode) Thermal resistance network model Heating of the sample by the probe operating in active mode (in dc or ac regimes) Q t,s written as a function of : the thermal power P used for the heating of the probe, the measured probe temperature T probe the thermal property to be determined,,,,,, For bulk and homogeneous thick samples, the sample thermal conductivity λ s included in the expression of the sample thermal spreading resistance r th,s r th, s 1 = 4 λ s b Heated area on the sample surface assumed circular of effective radius b and isothermal. [Yovanovich et al. Heat Transfer Handbook, 2003. 1] 19

Energy balance Thermophysical measurement (active mode) The ideal situation for an easy estimation of the sample thermal conductivity should be that λ s is included in the expression of r th,s only, the tip apex temperature T t,c = T probe. In this case: = 4λ b( T T )/( 1+ λ br ) Q t s s t, c a 4 s th, c For Q s to depend primarily on λ s, 4bλ s r th,c <<1 must be satisfied: the dominant thermal resistance should be that of the sample. SThM measurements mainly sensitive to λ s for materials of low thermal conductivity. [David, L. Ph.D Thesis, University of Lyon 2006 ] Calibration curve G = 1/r th,c 20

Energy balance Thermophysical measurement (active mode) The ideal situation for an easy estimation of the sample thermal conductivity should be that λ s is included in the expression of r th,s only, the tip apex temperature T t,c = T probe. In this case: = 4λ b( T T )/( 1+ λ br ) Q t s s t, c a 4 s th, c For Q s to depend primarily on λ s, 4bλ s r th,c <<1 must be satisfied: the dominant thermal resistance should be that of the sample. SThM measurements mainly sensitive to λ s for materials of low thermal conductivity. However, T t,c T probe resistive probes have an extended thermosensitive element [David, L. Ph.D Thesis, University of Lyon 2006 ] Calibration curve G = 1/r th,c 21

Energy balance Thermophysical measurement (active mode) The ideal situation for an easy estimation of the sample thermal conductivity should be that λ s is included in the expression of r th,s only, the tip apex temperature T t,c = T probe. In this case: = 4λ b( T T )/( 1+ λ br ) Q t s s t, c a 4 s th, c For Q s to depend primarily on λ s, 4bλ s r th,c <<1 must be satisfied: the dominant thermal resistance should be that of the sample. SThM measurements mainly sensitive to λ s for materials of low thermal conductivity. [David, L. Ph.D Thesis, University of Lyon 2006 ] Calibration curve r th,c : 5.10 6 K.W -1 to 8.10 6 K.W -1 b : several micrometers However, T t,c T probe r th,c and b strongly depend on λ s Measurements under air env. G = 1/r th,c [Assy A., Ph.D Thesis, University of Lyon 2015.] 22

Energy balance Thermometry and Thermophysical measurements Q s-t or Q t-s and then the errorδt (in thermometry) depend on many parameters characterizing: o the surrounding gas (pressure, temperature, degree of relative humidity), o the tip-sample mechanical contact: mechanical properties of tip and surface, tip-sample force, surface roughness and topography, o the thermophysical properties of probe and sample. The estimation of all the involved parameters through modelling is not trivial and is still one of the main limitations of SThM involving nanoprobes Experimental calibration methodologies proposed 23

Measurement modelling Depending on the probe, various analytical and numerical models proposed to link the nominal signal effectively measured and the parameters to be determined. The most used analytical thermal model based on the resolution of the heat equation in the probe described as thermal fins. Models consider geometrical and dimensional parameters the physical properties of materials to describe the probe effective parameters such as: o an effective coefficient h / heat losses by the whole probe surface to its environment, to describe the probe-sample thermal interaction o an effective thermal resistance r th,c o an effective thermal radius b. an appropriate description of the sample depending on its shape, Models used to determine : unknown modeling parameters from comparison with measurements in well controlled configurations (surrounding, reference samples, ) through calibration 24

Measurement modelling Example : 2 2 θ hp ρ I 1 θ + (1 + αθ ) = θ 2 2 x λs λs a t T a θ L L λs ( x = ) = Geqθ ( x = ) x 2 2 Sample thermal resistance 1/ G eq =,, Contact thermal resistance 25

Calibration methods The fitting of simulated measurement with experimental data in well-known conditions (various surrounding conditions, various frequencies of heating of the probe, various samples ) identification of the modelling parameters h, R th,c, b and the probe characteristics such as its time response. Measurements under ambient conditions, no contact with a sample low pass filter of cut-off frequency about f c = 800 Hz. Once f c is experimentally determined, the effective radius r p and the effective half-length L p of the tip can be determined from the modeling. Once calibrated for a given experimental configuration (probe and surrounding environment), the modelling is used to characterize unknown specimens from measurements performed in the same configuration. 26

Calibration methods implemented for the determination of Use of laboratory self-heating samples. Self-heating samples fabricated for SThM calibration include : instruments that are specifically designed for absolute temperature measurements on the scale of one micron : Johnson noise in a small metallic resistor, or instrumented membrane. hot sources implemented in subsurface volume with a metallic line heated through joule effect. Samples o generally heated in ac regime to demonstrate thermal mapping with low signal-to-noise ratio. o used to characterize the dynamic response of sensors, which is also an important parameter to be considered. Calibration methods Thermometry measurements Based on comparisons of SThM measurements with : either measurements obtained by optical thermometry methods, either results of simulation of the sample surface temperature (or both). 27

Calibration methods Thermometry measurements Calibration methods implemented for the determination of However, Optical thermometry methods have a spatial resolution limited to few hundred nanometers Simulations at micro and nanometric scales are often dependent on simplifications or critical parameters. These comparisons are then not strictly applicable to SThM temperature measurements with a spatial resolution of a few tens of nanometers. Accurate temperature measurements after calibration are only possible on samples that hold almost the same surface properties than the ones of the calibration samples. 28

Calibration methods Thermal conductivity measurements Other example of calibration (purely experimental) The calibration can be performed with a set of experiments involving flat bulk samples of well-known thermal conductivities in a range that covers the expected value of the thermal conductivity k s to be measured. Practically, the tip heated with an increase of temperature larger than 80 K to ensure a good signal to noise ratio and avoid issues related to the presence of a water meniscus. 29

Scanning thermal microscopy: SThM Main current issues Bilan

Current issues What is about the smallest probes? 31

Size effects Sensitivity to thermal conductivity reduced compared to the one of larger and metallic probes due to nanoscale size effects. L ph in pure crystalline Si @ 300nm (Ta) >> sizes of the tip apex of the Si nanoprobes Macroscopic description does not accurately model the heat flow and the heat conduction through the tip is modelled as quasi-ballistic transport. Additional thermal resistance to describe heat transfer at the probe apex. Nanoscale size effects on the sample spreading resistance 32

Probe-sample heat transfer A better understanding of the thermal interaction between a SThM tip and a sample is crucial for a good understanding of measurement and a good interpretation of the contrast of thermal images. 33

Probe-sample heat transfer Complex Various mechanisms of heat transfer Various length scale to be considered d Far field heat transfer λ rad,th, max Near field heat transfer Heat from tip to sample T tip > T sample Tip Diffusive conduction through air d < Λ air Ballistic conduction through air Conduction through water meniscus Tip apex Probe roughness Sample surface Sample Conduction through solidsolid interface Atomic scale and roughness Visite Comité HCERES 15-16 janvier 2015 34

Probe-sample heat transfer Complex Various mechanisms of heat transfer Various length scale to be considered d Far field heat transfer Generaly neglected if not specifically Near studied field heat transfer λ rad,th, max Heat from tip to sample T tip > T sample Tip Diffusive conduction through air d < Λ air Ballistic conduction through air Conduction through water meniscus Tip apex Probe roughness Sample surface Sample Conduction through solidsolid interface Atomic scale and roughness Visite Comité HCERES 15-16 janvier 2015 35

Heat transfer through air If not under vacuum conditions, a large area of the probe is in contact with the air lying around and can heat it. Hot air can then heat the sample. The hot part of the tip can extend over tens of micrometres in some SThM probes the heated part of the sample could potentially be as large: heat transfer mechanism extremely efficient. impact on spatial resolution of SThM. Thermal imaging of Silicon nanowires (diameter lower than 100nm) in SiO2 matrix 36

Heat transfer through air Different heat transfer mechanisms depending on the probe-sample distance When the heater is far from the tip end and therefore from the sample, strong probe-sample air heat transfer also occurs, with air being heated at the area of the conical tip or directly by the cantilever. When the tip-sample distance is large, heat convection can occur: the heat flux will be carried by the motion of air generated by the temperature difference A large part of the heat can be lost in the air because heat lost by a hot tip does not necessarily flow towards the sample. At shorter distances (few micrometres and below), heat diffusion: main mechanism of heat transfer through the air. The heat transfer can then be modelled with standard Finite-Element Modelling (FEM) tools. 37

Heat transfer through air Different heat transfer mechanisms depending on the probe-sample distance When the distance reaches few hundreds of nanometres, ballistic heat transfer: The mean free path of the heat carriers L gas, here air molecules (mostly nitrogen ones), becomes comparable with the tip-sample distance (L air ~70nm at P=1 bar) When d < Λ gas (Kn gas >1), the continuum assumption is not appropriate. This concerns the very end of the tip where d is smaller than some µm, or when the probe is operated in very low vacuum (Pressure <1 mbar). 38

Heat transfer through water meniscus Reminder G air from 10-8 W.K -1 to 10-6 W.K -1 depending on the size of the tip. G total as a function of the probe mean temperature T m T a = 30 ⁰C, RH= 40 %. Good agreement with previous works of Majumdar et al. with a SThM thermocouple probe with nanometric curvature radius G total = 6.7 nw/k 39

Heat transfer through solid-solid contact The radius of the mechanical contact a generally estimated from mechanical contact theories. Let us consider measurements under vacuum and a contact sufficiently heated so that we can neglect water These theories apply to the contact between a sphere and a flat surface and their use leads to consider an ideal contact between surfaces of perfect quality. Whatever the considered SThM tip,. a estimated to be lower than a few tens of nm. For such nanoscale contacts, phonon mismatch and mechanical contact geometry to be accounted. 40

Heat transfer through solid-solid contact Thermal boundary resistance to be considered due to the difference in phonon dispersion between the two materials in contact. R th, contactb = R πb t h, B 2 c, p R th,b a thermal boundary resistance that has the same units as the bulk thermal contact resistance. The values of R th,b experimentally determined for solid-solid contacts near room temperature typically lie in the rangle 5.10-7 - 5.10-9 m 2.K.W -1 41

Heat transfer through solid-solid contact However in reality Conduction through atomic scale interface The tip-sample interface never perfect: contamination or oxide layers can cover surfaces contact area is non-continuous due to weak coupling bonds between the atoms of solids or surface roughness 42

Heat transfer through solid-solid contact Due to the roughness of the tip and sample surfaces, the apparent contact surface is not continuous. The surface can be divided into smaller contact area. Appropriate modelling of this effect depends on the ratio of the averaged mean free path of heat carriers Λ c to the size b c. If b c >> Λ c, diffusive transport applies. Classical solutions are applicable: G th, contact = Kksbc where K is a geometrical factor describing the heat spreading within the sample. If b c < Λ c, ballistic solutions must be considered. When b c <<< Λ c, the notion of finite contact spots may be extrapolated to the atomic scale. Quantization of thermal conductance? 43

Lecture 2: Measurements with contact in heat transfer: principles, implementation and pitfalls F Lanzetta, B Garnier, S Gomès Conclusions Metti 6 Advanced School: Thermal Measurements and Inverse Techniques Biarritz, March 1-6, 2014

Conclusions Accurate temperature measurement is not an easy task whatever the considered length scale is. Errors depend on : thermosensitive phenomena, the sensor which can create local temperature disturbance and therefore bias. Very often, this latter error is ignored. In this lecture dedicated to contact thermal measurement, one have tried to provide to the readers the know-how in various situations (temperature measurement in fluids or opaque medium ) in order to perform the best measurements as possible. Thermal measurement at micro and nanoscales using Scanning Thermal Microscopy were presented. The crucial step of calibration, the limitations and current issues of the method were given. The complexity of the tip-sample heat transfer at micro and nanoscale was discussed. This explains why its deep understanding is required in order to obtain the best achievements of the techniques. Metti 6 Advanced School: Thermal Measurements and Inverse Techniques Biarritz, March 1-6, 2014

Thanks a lot for your attention! Questions? Metti 6 Advanced School: Thermal Measurements and Inverse Techniques Biarritz, March 1-6, 2014