Contrast mechanisms in polarization-sensitive Mueller-matrix optical coherence tomography and application in burn imaging

Similar documents
Degree of polarization in laser speckles from turbid media: Implications in tissue optics

Imaging thermally damaged tissue by polarization sensitive optical coherence tomography

Multiple-source optical diffusion approximation for a multilayer scattering medium

Polarization properties of corner-cube retroreflectors: Theory and experiment

Ambiguity of optical coherence tomography measurements due to rough surface scattering

Flow measurement without phase information in optical coherence tomography images

Mueller Coherency matrix method for contrast image in tissue polarimetry

Brewster Angle and Total Internal Reflection

Waveplate analyzer using binary magneto-optic rotators

Polarization algebra: decomposition of depolarizing Mueller matrices

Brewster Angle and Total Internal Reflection

Polarized Light. Second Edition, Revised and Expanded. Dennis Goldstein Air Force Research Laboratory Eglin Air Force Base, Florida, U.S.A.

Lecture 5: Polarization. Polarized Light in the Universe. Descriptions of Polarized Light. Polarizers. Retarders. Outline

TIME-DOMAIN POLARIZATION-SENSITIVE OPTICAL COHERENCE TOMOGRAPHY IN SOFT BIOLOGICAL TISSUE

Intuitive interpretation of Mueller matrices of transmission. John Freudenthal Hinds Instruments, Inc.

Degradation in the degree of polarization in human retinal nerve fiber layer

University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography

ELLIPSOMETRY AND POLARIZED LIGHT

Chap. 5. Jones Calculus and Its Application to Birefringent Optical Systems

POLARISATION-SENSITIVE OPTICAL COHERENCE TOMOGRAPHY FOR MATERIAL CHARACTERISATION AND TESTING

Resolution improvement in optical coherence tomography with segmented spectrum management

Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a).

Angular distribution of diffuse reflectance in biological tissue

Polarimetry in the E-ELT era. Polarized Light in the Universe. Descriptions of Polarized Light. Polarizers. Retarders. Fundamentals of Polarized Light

Polarization degree fading during propagation of partially coherent light through retarders

Lecture 4: Anisotropic Media. Dichroism. Optical Activity. Faraday Effect in Transparent Media. Stress Birefringence. Form Birefringence

A high-accuracy universal polarimeter study of optical anisotropy and optical activity in laminated collagen membranes

AVAZ inversion for fracture orientation and intensity: a physical modeling study

FUNDAMENTALS OF POLARIZED LIGHT

In Vivo Total Retinal Blood Flow Measurement by Fourier. domain Doppler Optical Coherence Tomography

Analytical Form of Frequency Dependence of DGD in Concatenated Single-Mode Fiber Systems

Microwave-induced thermoacoustic tomography using multi-sector scanning

Full-field birefringence imaging by thermal-light polarization-sensitive optical coherence tomography. I. Theory

Chap. 2. Polarization of Optical Waves

Effect of source spectral shape on task-based assessment of detection and resolution in optical coherence tomography

Introduction to Polarization

arxiv: v1 [physics.optics] 20 Feb 2008

3.4 Elliptical Parameters of the Polarization Ellipse References

Angular Spectrum Representation for Propagation of Random Electromagnetic Beams in a Turbulent Atmosphere

University of Cyprus. Reflectance and Diffuse Spectroscopy

PMARIZED LI6HT FUNDAMENTALS AND APPLICATIONS EBWABD COLLETT. Measurement Concepts, Inc. Colts Neck, New Jersey

10. OPTICAL COHERENCE TOMOGRAPHY

Backscattering enhancement of light by nanoparticles positioned in localized optical intensity peaks

Scattering properties of the retina and the choroids determined from OCT-A-scans

Analysis of second-harmonic generation microscopy under refractive index mismatch

Typical anisotropies introduced by geometry (not everything is spherically symmetric) temperature gradients magnetic fields electrical fields

Spectral Degree of Coherence of a Random Three- Dimensional Electromagnetic Field

Mueller matrix approach for determination of optical rotation in chiral turbid media in backscattering geometry

Improved solutions of the steady-state and the time-resolved diffusion equations for reflectance from a semi-infinite turbid medium

Polarized light propagation and scattering in random media

Temporal modulation instabilities of counterpropagating waves in a finite dispersive Kerr medium. II. Application to Fabry Perot cavities

Scattering of light from quasi-homogeneous sources by quasi-homogeneous media

Local normal-mode coupling and energy band splitting in elliptically birefringent onedimensional

Advanced Optical Coherence Tomography techniques: novel and fast imaging tools for non-destructive testing

Polarization Optics. N. Fressengeas

Second Harmonic Diagnostics for Real-Time Monitoring of Biological Macromolecules Structural Changes

Chapter 2 Advanced Mueller Ellipsometry Instrumentation and Data Analysis

Coherent Superposition of Mueller-Jones States: Synthesizing Mueller Matrices with an Ellipsometer

Optics. n n. sin c. sin

Vector theory of four-wave mixing: polarization effects in fiber-optic parametric amplifiers

Lecture 8: Polarimetry 2. Polarizers and Retarders. Polarimeters. Scattering Polarization. Zeeman Effect. Outline

Polarized Light Assessment of Complex Turbid Media Such as Biological Tissues Using Mueller Matrix Decomposition

16. More About Polarization

UE SPM-PHY-S Polarization Optics

Chap. 4. Electromagnetic Propagation in Anisotropic Media

Coherence and Polarization Properties of Far Fields Generated by Quasi-Homogeneous Planar Electromagnetic Sources

Nate J. Kemp, Haitham N. Zaatari, Jesung Park, H. Grady Rylander III, and Thomas E. Milner

Polarization. Polarization. Physics Waves & Oscillations 4/3/2016. Spring 2016 Semester Matthew Jones. Two problems to be considered today:

P137 Our Experiences of 3D Synthetic Seismic Modeling with Tip-wave Superposition Method and Effective Coefficients

Polarimetry. Dave McConnell, CASS Radio Astronomy School, Narrabri 30 September kpc. 8.5 GHz B-vectors Perley & Carilli (1996)

Strongly enhanced negative dispersion from thermal lensing or other focusing effects in femtosecond laser cavities

Polarization division multiplexing system quality in the presence of polarization effects

B 2 P 2, which implies that g B should be

Shannon entropy of partially polarized and partially coherent light with Gaussian fluctuations

Jones calculus for optical system

Orthogonalization Properties of Linear Deterministic Polarization Elements

Vector diffraction theory of refraction of light by a spherical surface

Analysis of guided-resonance-based polarization beam splitting in photonic crystal slabs

Light propagation in structural anisotropic media in the steady-state and time domains

Ellipsometry. Introduction. Measurement Principles

1 The formation and analysis of optical waveguides

Experimental generating the partially coherent and partially polarized electromagnetic source

Optics and Optical Design. Chapter 6: Polarization Optics. Lectures 11-13

Optical Fiber Signal Degradation

Photonic nanojet enhancement of backscattering of light by nanoparticles: a potential novel visible-light ultramicroscopy technique

Detection and characterization of optical inhomogeneities with diffuse photon density waves: a signal-to-noise analysis

Engineering Note. Measuring the Polarization Rotation Angle of a Faraday Rotator Mirror with the Optical Vector Analyzer

Polarimetry noise in fiber-based optical coherence tomography instrumentation

Testing stress birefringence of an optical window. Chiayu Ai and. James C. Wyant. WYKO Corp., 2650 E. Elvira Road, Tucson, AZ ABSTRACT

Complex refractive-index measurement based on Fresnel s equations and the uses of heterodyne interferometry

Separation of absorption and scattering profiles in spectroscopic optical coherence tomography using a least-squares algorithm

Direct measurement of electric-field-induced birefringence in a polymer-stabilized blue-phase liquid crystal composite

Lecture 11: Polarized Light. Fundamentals of Polarized Light. Descriptions of Polarized Light. Scattering Polarization. Zeeman Effect.

PRINCIPLES OF PHYSICAL OPTICS

Quantitative retinal blood flow measurement with. three-dimensional vessel geometry determination. using ultrahigh-resolution Doppler optical

Transmission matrices of random media: Means for spectral polarimetric measurements

Ji Qi*,1,2 and Daniel S. Elson*,1,2

Lichtausbreitung in streuenden Medien: Prinzip und Anwendungsbeispiele

WAVE PROPAGATION AND SCATTERING IN RANDOM MEDIA

Parallel fractional correlation: implementation

Transcription:

Contrast mechanisms in polarization-sensitive Mueller-matrix optical coherence tomography and application in burn imaging Shuliang Jiao, Wurong Yu, George Stoica, and Lihong V. Wang We investigate the various contrast mechanisms provided by polarization-sensitive PS Mueller-matrix optical coherence tomography OCT. Our PS multichannel Mueller-matrix OCT is the first, to our knowledge, to offer simultaneously comprehensive polarization-contrast mechanisms, including the amplitude of birefringence, the orientation of birefringence, and the diattenuation in addition to the polarization-independent intensity contrast, all of which can be extracted from the measured Jones or the equivalent Mueller matrix. Theoretical analysis shows that when diattenuation is negligible, the roundtrip Jones matrix represents a linear retarder, which is the foundation of conventional PS-OCT, and can be calculated with a single incident polarization state, although the one-way Jones matrix generally represents an elliptical retarder; otherwise, two incident polarization states are needed. The experimental results obtained from rat skin samples, which conform well with the histology, show that Mueller OCT provides complementary structural and functional information on biological samples and reveal that polarization contrast is more sensitive to thermal degeneration of biological tissue than amplitude-based contrast. Thus, Mueller OCT has significant potential for application in the noninvasive assessment of burn depth. 2003 Optical Society of America OCIS codes: 120.2130; 170.4500; 260.5430; 170.1870. 1. Introduction Since it was first reported approximately a decade ago as a high-resolution noninvasive medical imaging modality, optical coherence tomography OCT has received tremendous attention. Several branches of OCT have been developed based on various contrast mechanisms, such as polarization 1 6 and Doppler shift, 7,8 in addition to the amplitude-based contrast in conventional OCT. OCT has found applications in imaging of the retina, cornea, gastrointestinal tract, artery, tooth, bladder, blood flow, and brain cortex. 9 Another potential application of OCT is the evaluation of burns in biological tissue. 10 The contrast of an OCT image is provided by the optical properties of a sample that modify the parameters of the light The authors are with Texas A&M University, 3120 TAMU, College Station, Texas 77843-3120. S. Jiao, W. Yu, and L. V. Wang LWang@tamu.edu are with the Optical Imaging Laboratory, Department of Biomedical Engineering. G. Stoica is with the Department of Pathobiology. Received 18 January 2003; revised manuscript received 28 May 2003. 0003-693503255191-07$15.000 2003 Optical Society of America field, including the amplitude and the polarization state. The parameters characterizing the structurally isotropic or averaged optical properties 11 of a sample include the absorption coefficient a, scattering coefficient s, scattering anisotropy g, and refractive index n; and the parameters characterizing the polarization properties of a sample include birefringence amplitude n, orientation, and ellipticity and diattenuation amplitude D, orientation, and ellipticity, which provide polarization-based contrast in polarization-sensitive OCT PS-OCT. Because of the interference-based heterodyne detection scheme used in OCT, a scattering sample acts as a nondepolarizing medium. 4 The polarization properties of a nondepolarizing sample can be completely characterized by either a Mueller matrix or a Jones matrix, and the two matrices are equivalent. 12 Therefore, to provide comprehensive information about polarization of a sample, the most general PS- OCT should measure the Jones or the Mueller matrix. Upon acquisition of the Jones or the Mueller matrix, any polarization parameters can be extracted. We define Mueller-matrix OCT as PS-OCT that can measure the Mueller or the Jones matrix of a sample. Therefore, Mueller-matrix OCT is the most general form of PS-OCT. 1 September 2003 Vol. 42, No. 25 APPLIED OPTICS 5191

In this paper, we investigate the various contrast mechanisms provided by Mueller-matrix OCT. The properties of the round-trip Jones matrix are analyzed for conditions with and without diattenuation in a sample. The analyses indicate that when diattenuation is negligible, one incident polarization state is adequate for the acquisition of the Jones matrix. When diattenuation cannot be neglected, two incident polarization states are necessary, and the transpose symmetric property of the round-trip Jones matrix first discovered by our group 5 offers a critical condition for the calculation of the Jones matrix correctly. Experimental results with biological samples are presented. 2. Polarization-Based Contrast Diattenuation is a description of the dependence of transmittance on the incident polarization states and is defined as D P 2 q P 2 r P 2 q P 2 r, (1) where P q and P r represent the amplitude transmittances for the two orthogonal eigenpolarizations of a polarization element. Therefore, diattenuation provides anisotropic amplitude-based contrast, as it incurs no phase retardation. Birefringence is a description of the anisotropic dependence of the phase velocity of light in a sample on the incident polarization states. The phase retardation of a light field, induced by the local birefringence between the two orthogonal eigenpolarizations, can be expressed as d k nl s dl s, where k is the wave vector corresponding to the central wavelength of the incident light in vacuum; L s is the physical path length that the light travels in the birefringent medium; nl s is the local birefringence; and dl s is the local physical path length. The phase retardation provides a unique phase-based polarization-contrast mechanism reflecting the amplitude of birefringence, which exists in various biological components such as collagen, keratin, myelin, and elastic fibers. Because highly birefringent collagen is a predominant structural component in most biological tissues, this intrinsic contrast mechanism is prevalent in the biomedical applications of Mueller OCT. In addition, many degenerative processes of biological tissues alter birefringence and should, thus, be detectable by Mueller-matrix OCT. In a PS-OCT system, the detected variation of the polarization state of the scattered light in reference to the incident light is affected by the round-trip polarization effect of a sample, which can be characterized with a round-trip Jones matrix J 2. We will use subscripts 1 and 2 to describe the one-way and round-trip parameters, respectively. After acquisition of the round-trip Jones matrix, the round-trip retardation 2 and diattenuation D 2 for each pixel of the OCT image can be calculated with the following formulas, 13 1 2 2cos 1 trj 2 det J 2 det J 2 trj 2 * 2 trj 2 *J 2 2det J 2, (2) 12 2 D 2 1 4det J 2 2 12, (3) trj 2 *J 2 respectively, where *, tr, and det represent the Hermitian transpose conjugate, trace, and determinant of the matrix, respectively. The fast eigenvector of J 2 at each pixel of the OCT image, E 2 E 2h E 2v, can be calculated through standard algorithms. The orientation of the fast axis can thus be calculated as 2 arc tan E 2v E 2h. (4) 3. Calculation of the Round-Trip Jones Matrix The round-trip Jones matrix J 2 can be expressed with the one-way Jones matrix J 1, according to the Jones reversibility theorem, as J 2 J 1 T J 1, (5) where the superscript T represents the transpose operation. A polarization element is called homogeneous when the two eigenvectors of its Jones matrix are orthogonal. A retarder is called elliptical when its eigenpolarizations are elliptical polarization states. A linear retarder is a special case in which the eigenpolarizations are linear, and a Faraday rotator is another special case in which the eigenpolarizations are circular. We can prove that when two or more linear retarders are cascaded, the overall retarder is generally elliptical unless the axes of the retarders are aligned. Except in some special samples, the orientations of the birefringent fibers in biological samples, take skin, for example, are not collinear, and as a result, J 1 generally represents a homogeneous elliptical retarder if diattenuation is negligible in the sample. When diattenuation is negligible in a sample, J 1 can be expressed as J 1 1, 1, 1 cos 12 i sin 1 2cos 2 1 i sin 1 2sin 2 1 expi 1 i sin 1 2sin 2 1 expi 1 cos 1 2 i sin 1 2cos 2 J 1 1 1,1 J 1 1,2 (6) J 1 1,2* J 1 1,1*. 5192 APPLIED OPTICS Vol. 42, No. 25 1 September 2003

The fast and slow eigenvectors are cos 1 sin 1 expi 1 and sin 1 expi 1 cos 1, respectively, where 1 is an auxiliary angle and 1 represents the phase difference between the two components of the fast eigenvector. 1 is the phase difference between the two eigenvalues the retardation. The azimuth 1 of the major axis of its fast eigenpolarization can be expressed as tan2 1 tan2 1 cos 1. If 1 0, J 1 is transpose symmetric, representing a linear retarder, and 1 represents the orientation of the fast axis. From Eq. 5, we have J 2 J T 2, i.e., J 2 is transpose symmetric. As a result, J 2 represents a linear retarder, and we can thus conclude that the round-trip transformation effect of an elliptical retarder is equivalent to the one-way transformation of a linear retarder. This conclusion is the foundation of conventional PS-OCT, in which a sample is treated as a linear retarder. Since only two parameters are needed to characterize a linear retarder, the number of parameters needed to characterize the round-trip polarization properties of a sample is reduced to two. This conclusion allows the acquisition of this type of round-trip Jones matrix with only one incident polarization state. For an incident polarization state E i E ih E iv, the output polarization state E o E oh E ov detected by PS-OCT can be expressed as E oh E ov J 2 E ih E iv. (7) Because of the orthonormal transformation property of J 2, the inherent property of a retarder, we also have E ov* J E oh * 2 E iv*. (8) E ih * The round-trip Jones matrix can thus be calculated as J 2 E oh E ov * E ov E oh * E 1 ih E iv *. (9) E iv E ih * When diattenuation cannot be neglected in a sample, one incident polarization state is not sufficient to acquire its round-trip Jones matrix because five real parameters 2, 2, amplitude transmittances P q2 and P r2, and the orientation of diattenuation d2 are needed to characterize such a system. Therefore, at least two incident polarization states, either applied at the same time or applied sequentially, are required. The transpose symmetry in the roundtrip Jones matrix is critical for eliminating the arbitrary phase difference between the two measured Jones vectors corresponding to the two incident polarization states to yield the correct Jones matrix. This arbitrary phase difference can be caused either by the nonidentity of the power spectra when two light sources are used or by the imperfection of the longitudinal scanning mechanism when the two incident polarization states are applied sequentially. Because it ignores the diattenuation effect completely, conventional PS-OCT is not valid for biological samples possessing diattenuation and cannot provide diattenuation contrast. 4. Experiment We have built a novel multichannel Mueller OCT, 5,6 which can acquire the Jones matrix of a sample with a single scan for each one-dimensional depth image A line image. The Jones matrix can be further transformed into an equivalent Mueller matrix. The Mueller matrix is preferred because its first element, M 00, represents the intensity transformation property of a sample and is free of both the effects of the sample polarization and the polarization state of the incident light. Therefore, a Mueller matrix reveals the real morphologic structure as well as the polarization-based features of a sample. The tail of a rat was imaged in situ with Mueller OCT after the skin was shaved and scrubbed with glycerin. The OCT and polarization-histologic images are shown in Figs. 1a 1f. There are no significant differences between the M 00 image Fig. 1b and the conventional OCT image for this particular sample Fig. 1a, both of which are amplitude based. The effect of polarization on a conventional OCT image depends on several parameters, for example, the incident polarization state, the value and orientation of the birefringence, and the accumulated phase retardation. When fringes are present in the conventional OCT image, the difference between these two images is dramatic. 5 The intensity and retardation images reveal different characteristics of the sample. The intensity images clearly reveal the boundaries of the structures in the epidermis and only the shallow dermal region. In contrast, the retardation image Fig. 1c reveals the distribution of birefringent components deeper into the dermis. The absolute value of the retardation difference between each pixel and its previous pixel in the same A line is calculated to obtain a differential retardation image Fig. 1d. The birefringent regions corresponding to the superficial keratin layer and collagen-rich dermal papillae and nonbirefringent regions corresponding to fat and the living epidermis are shown more clearly in the differential retardation image than in the raw retardation image. The im- 1 September 2003 Vol. 42, No. 25 APPLIED OPTICS 5193

Fig. 1. a Conventional OCT image in logarithmic scale, b intensity image M 00, in logarithmic scale, c retardation image, d differential retardation image, e image of the orientation of the fast axis, f polarization histologic image of an in situ rat tail. The height of each image is 750 m. The gray scales are for the orientation 2 and the retardation 2 images. The conventional OCT image was obtained with vertical linear polarization states for both the incident and the reference beams. F, fat; K, keratin; DP, dermal papilla. age of the orientation of the fast axis Fig. 1e revealed structures that we believe to be related to the distribution of the orientation of the birefringent fibers collagen and keratin. In the figure, we can see that the orientation of the fast axis varies from region to region as also observed in the polarization histology. Although the amplitudeand phase-based polarization signals should have comparable signal-to-noise ratios because they are computed from the same measurements, the contrast-to-noise ratio can be different depending on the availability of the two contrasts in the sample; therefore, the two contrast mechanisms can provide information into different depths. To evaluate the sensitivity of the phase-based polarization contrast in burn-depth determination, we imaged an ex vivo skin sample from a rat belly containing a burn lesion. The burn lesion was made by touching the skin with a heated approximately 100 C electric iron for less than 1 s. The calculated intensity image, the retardation image, the diattenuation image and the histological image are shown in Figs. 2a 2d. The burn region cannot be identified in the intensity image; but it can be clearly seen with marked contrast in the retardation and diattenuation images as verified by the polarization histological image. Figure 3 shows the depth profiles of retardation of the burn and normal regions, respectively. Each curve is an average of 10 profiles in the central area of the burn region and in the normal region to the right side of the burn region. The loss of birefringence in the burn region compared with the normal tissue can be seen clearly. This figure further demonstrates that phase-based polarization contrast provides a sensitive mechanism for evaluating thermal degeneration of biological tissue. Because birefringence and diattenuation are related to the function of Fig. 2. a Intensity image M 00, in logarithmic scale, b retardation image, c diattenuation image, d polarization histologic image of a piece of ex vivo rat skin with a burn lesion. The height of each image is 750 m. The gray scales are for the retardation 2 and the diattenuation D 2 images. B, burn region. 5194 APPLIED OPTICS Vol. 42, No. 25 1 September 2003

Fig. 3. Average of 10 depth profiles of the retardation around the center of the burn area and the normal region to the right of the burn area. several kinds of biological component such as collagen, Mueller OCT is a type of functional imaging. 5. Discussion The differences between conventional OCT and Mueller OCT in their sensitivities to different optical properties of a sample result from their different contrast mechanisms. Conventional OCT is an amplitude-based detection system, which detects the local relative variations of path-length-resolved reflectance from tissues. By modifying an existing theoretical model of OCT 14 to include the effect of polarization, we can express the signal in conventional OCT as RLs 12 cosl s exp Ĩ d L r 2I s I r 12 4LL c 2 cosk LdL s, (10) where L s and L r are the round-trip optical path lengths of the sample and reference arms, respectively; L L s L r is the round-trip optical pathlength difference; L c is the coherence length of the light source; I r is the intensity of the reference beam; I s is the reflected intensity of the sample arm; RL s di s L s dl s I s is the path-length-resolved reflectance of the sample; and L s is an equivalent angle between the polarization states of the reference and the backscattered sample beams, defined as cosl s E s L s E r E s L s E r, where E s L s and E r are the electric vectors of the sample and the reference beams, respectively, and the angle brackets denote a time average. The integrand is nonzero mainly in the interval L L c. The integration produces a significant value only when RL s varies sharply across a dimension of L c ; otherwise, the integral tends to be zero because of the cosine term in the integrand. A sharp variation of RL s is caused by interfaces between regions of different optical properties. Conventional OCT is, in principle, very sensitive to discontinuity of the refractive index n as a result of specular reflection. As studied by Pan et al., 14,15 conventional OCT is also sensitive to variations of the anisotropy g and the scattering coefficient s, but it is insensitive to variation of the absorption coefficient a. We can see in Eq. 10 that the polarization effect of a sample contributes to the recorded conventional OCT signal as an amplitude modulation and is superimposed on the backreflection effect; consequently, conventional OCT has difficulty in separating the polarization effect from the real morphologic effect of the sample. To account for the meanings of the measured retardation image, we can divide each depth scan into a number of homogenous segments, each of which has a length less than the axial resolution; each segment can be characterized by a Jones matrix J 1 ii 1, 2,..., which is a function of the equivalent local birefringence ni, orientation of the fast axis 1 i, amplitude transmittances P q1 i and P r1 i, and orientation of the diattenuation d1 i. For single backscattering and even multiple small-angle scattering, the equivalent round-trip Jones matrix of contiguous m segments of the sample from the surface to the mth segment can be expressed as m J m 2 J T 1 i i1 im J 1 i. The equivalent round-trip parameters for the m segments, such as the retardation m 2, orientation of the fast axis m 2, and diattenuation, can be calculated from J m 2. When 1 1 d1 1 1 2 d1 2... 1 m d1 m, if m 2, m 2 in the retardation image increases with depth, whereas 2 m keeps constant; if m 2 covers a range greater than, it causes fringes in both the retardation and the orientation images because a retarder J m 2, m 2 is equivalent to a retarder J m 2, m 2 2, m 2, m 2 0,, a phenomenon observed in the retardation and orientation images of samples like porcine tendon. 5 In this case, the differential retardation image reflects a map of the local birefringence. Otherwise, m 2 and m 2 are also functions of both 1 i and d1 i in the optical path, making the retardation image complex to interpret rigorously unless the local polarization properties can be calculated, which is possible only with Mueller OCT. The Jones matrix of the first pixel of each A line represents the round-trip Jones matrix of the first segment, i.e., J 1 2 J T 1 1J 1 1. If J 1 1 can be calculated from J 2 1 by developing some effective algorithms, the first segment can be peeled off to yield the T round-trip Jones matrix of the second segment, J 1 2J 1 2 J T 1 1 1 J 2 2 J 1 1 1. By use of this strategy layer by layer, the one-way Jones matrix of each segment can thus be extracted, and the images of the local polarization parameters can be calculated, which should be free of fringes because the retardation of each segment should be much less than. This algorithm is important in fiber-based PS- OCT system for eliminating the polarization dis- 1 1 September 2003 Vol. 42, No. 25 APPLIED OPTICS 5195

6. Conclusion In summary, a unique feature of Mueller OCT is its capability of separating various contrast mechanisms, in which the amplitude-based contrast is sensitive to the boundaries formed primarily by regions of different indexes of refraction, whereas the phasebased polarization contrast and the orientation-based contrast originate from the components of biological tissues with optical polarization effect. Experimental results show that phase-based polarization contrast is more sensitive to thermal degeneration of biological tissues than amplitude-based contrast. The combination of amplitude-based contrast with phase-based polarization contrast and the orientation-based contrast provides more comprehensive information about biological tissues. Phase-based polarization contrast is a promising imaging mechanism for assessing burn depth in vivo. Fig. 4. Averaged depth profiles of the intensity in logarithmic scale and retardation over the region marked with a horizontal white bar in Fig. 1b. Labels 1, 2, and 3, layers revealed. tortions on the measured polarization-based images caused by the sampling fiber. 16 Unlike amplitude-based contrast, phase-based polarization contrast is insensitive to a boundary caused by n, and, as a result, a boundary in the intensity image may not be reflected in the retardation image unless there is a corresponding difference of n across the boundary, the value of which also determines the sharpness of a boundary in the retardation image. Because of the integration over depth, a boundary caused by n in the retardation image may not be as sharp as the corresponding boundary caused by n in the intensity image. However, as can be seen in Fig. 2b, the interface between two regions of different n can be distinguished with sufficient accumulated contrast within a few coherence lengths. Figure 4 shows the depth profiles of intensity and retardation averaged laterally over the range marked by the white bar in Fig. 1b. The retardation curve revealed several layers from the surface down into the skin. Layers 1 and 3 are highly birefringent, indicating the keratin in the epidermis and the dermal papilla, respectively. Layer 2 has almost no birefringence, which likely corresponds to the living epidermis. We regard the apparent phase retardation induced by mechanisms other than birefringence as the background of the phase-based polarization contrast. Besides birefringence, scattering can also alter the polarization state of light and cause phase retardation. Alteration of the polarization state of the propagating light depends on the geometry and the refractive index of the scattering particles. 17,18 We thank G. Ku for help in preparing samples. This project was sponsored in part by the National Institutes of Health, grants R21 RR15368 and R01 EB000712; by the National Science Foundation, grant BES-9734491; and by the Texas Higher education Coordinating Board, grant 000512-0063-2001. References 1. M. R. Hee, D. Huang, E. A. Swanson, and J. G. Fujimoto, Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging, J. Opt. Soc. Am. B 9, 903 908 1992. 2. J. F. de Boer, T. E. Milner, M. J. C. van Gemert, and J. S. Nelson, Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography, Opt. Lett. 22, 934 936 1997. 3. G. Yao and L.-H. V. Wang, Two-dimensional depth-resolved Mueller matrix characterization of biological tissue by optical coherence tomography, Opt. Lett. 24, 537 539 1999. 4. S. Jiao, G. Yao and L.-H. V. Wang, Depth-resolved twodimensional Stokes vectors of backscattered light and Mueller matrices of biological tissue measured with optical coherence tomography, Appl. Opt. 39, 6318 6324 2000. 5. S. Jiao and L.-H. V. Wang, Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography, Opt. Lett. 27, 101 103 2002. 6. S. Jiao and L.-H. V. Wang, Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography, J. Biomed. Opt. 7, 350 358 2002. 7. Z. Chen, T. E. Milner, D. Dave, and J. S. Nelson, Optical Doppler tomography imaging of fluid flow velocity in highly scattering media, Opt. Lett. 22, 64 66 1997. 8. J. A. Izatt, M. D. Kulkarni, S. Yazdanfar, J. K. Barton, and A. J. Welsh, In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography, Opt. Lett. 22, 1439 1441 1997. 9. S. A. Boppart, M. E. Brezinski, C. Pitris, and J. G. Fujimoto, Optical coherence tomography for neurosurgical imaging of human intracortical melanoma, Neurosurgery 43, 1992 1998 1998. 10. B. H. Park, C. Saxer, S. M. Srinivas, J. S. Nelson, and J. F. de Boer, In vivo burn depth determination by high-speed fiberbased polarization sensitive optical coherence tomography, J. Biomed. Opt. 6, 474 479 2001. 11. G. Marquez, L.-H. Wang, S.-P. Lin, J. A. Schwartz, and S. L. Thomsen, Anisotropy in the absorption and scattering spectra of chicken breast tissue, Appl. Opt. 37, 798 804 1998. 12. C. Brosseau, Fundamentals of Polarized Light: A Statistical Optics Approach Wiley, New York, 1998. 13. S. Y. Lu and R. A. Chipman, Homogenous and inhomogenous Jones matrix, J. Opt. Soc. Am. A 11, 766 772 1994. 14. Y. Pan, R. Birngruber, J. Rosperich, and R. Engelhardt, Lowcoherence optical tomography in turbid tissue: theoretical analysis, Appl. Opt. 34, 6564 6574 1995. 5196 APPLIED OPTICS Vol. 42, No. 25 1 September 2003

15. Y. Pan, R. Birngruber, and R. Engelhardt, Contrast limits of coherence-gated imaging in scattering media, Appl. Opt. 36, 2979 2983 1997. 16. S. Jiao, W. Yu, G. Stoica, and L.-H. V. Wang, Optical-fiberbased Mueller optical coherence tomography, Opt. Lett. 28, 1206 1208 2003. 17. J. M. Schmitt and S. H. Xiang, Cross-polarized backscatter in optical coherence tomography of biological tissue, Opt. Lett. 23, 1060 1062 1998. 18. M. I. Mishchenko and J. W. Hovenier, Depolarization of light scattered by randomly oriented nonspherical particles, Opt. Lett. 20, 1356 1358 1995. 1 September 2003 Vol. 42, No. 25 APPLIED OPTICS 5197