Soil-Structure dynamic interaction: application to design and construction of the facilities of a gas power plant

Similar documents
Engineeringmanuals. Part2

Soil Behaviour in Earthquake Geotechnics

SHAKE TABLE STUDY OF SOIL STRUCTURE INTERACTION EFFECTS ON SEISMIC RESPONSE OF SINGLE AND ADJACENT BUILDINGS

Chapter 12 Subsurface Exploration

HIERARCHY OF DIFFICULTY CONCEPT: COMPARISON BETWEEN LINEAR AND NON LINEAR ANALYSES ACCORDING TO EC8

Soil-Structure Interaction in Nonlinear Pushover Analysis of Frame RC Structures: Nonhomogeneous Soil Condition

ANALYSIS OF LATERALLY LOADED FIXED HEADED SINGLE FLOATING PILE IN MULTILAYERED SOIL USING BEF APPROACH

Verification of a Micropile Foundation

EN Eurocode 7. Section 3 Geotechnical Data Section 6 Spread Foundations. Trevor L.L. Orr Trinity College Dublin Ireland.

The Bearing Capacity of Soils. Dr Omar Al Hattamleh

Project S4: ITALIAN STRONG MOTION DATA BASE. Deliverable # D3. Definition of the standard format to prepare descriptive monographs of ITACA stations

1.8 Unconfined Compression Test

Theory of Shear Strength

TABLE OF CONTENTS CHAPTER TITLE PAGE TITLE PAGE DECLARATION DEDIDATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK

Analysis of a single pile settlement

SHEAR STRENGTH OF SOIL

Gapping effects on the lateral stiffness of piles in cohesive soil

Estimation of the static vertical subgrade reaction modulus ks from CPT for flexible shallow foundations on cohesionless soils

VOLCANIC SOIL CHARACTERISATION AND SITE RESPONSE ANALYSIS IN THE CITY OF CATANIA ABSTRACT

PILE SOIL INTERACTION MOMENT AREA METHOD

Clayey sand (SC)

Chapter (12) Instructor : Dr. Jehad Hamad

Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil

NON-LINEAR ANALYSIS OF SOIL-PILE-STRUCTURE INTERACTION UNDER SEISMIC LOADS

Boreholes. Implementation. Boring. Boreholes may be excavated by one of these methods: 1. Auger Boring 2. Wash Boring 3.

NUMERICAL VERIFICATION OF GEOTECHNICAL STRUCTURE IN UNFAVOURABLE GEOLOGICAL CONDITIONS CASE STUDY

Cone Penetration Testing in Geotechnical Practice

Analysis of the horizontal bearing capacity of a single pile

SOME OBSERVATIONS RELATED TO LIQUEFACTION SUSCEPTIBILITY OF SILTY SOILS

BEHAVIOUR OF A FULL SCALE INSTRUMENTED FREE FLEXIBLE RETAINING WALL UNDER STATIC AND DYNAMIC CONDITIONS

FINITE GRID SOLUTION FOR NON-RECTANGULAR PLATES

Investigation of Liquefaction Behaviour for Cohesive Soils

Effective stress analysis of pile foundations in liquefiable soil

Theory of Shear Strength

Chapter (11) Pile Foundations

Case Study - Undisturbed Sampling, Cyclic Testing and Numerical Modelling of a Low Plasticity Silt

Mechanical Behaviors of Cylindrical Retaining Structures in Ultra-deep Excavation

CPT Applications - Liquefaction 2

DERIVATIVE OF STRESS STRAIN, DEVIATORIC STRESS AND UNDRAINED COHESION MODELS BASED ON SOIL MODULUS OF COHESIVE SOILS

Harmonized European standards for construction in Egypt

INTRODUCTION TO STATIC ANALYSIS PDPI 2013

Table 3. Empirical Coefficients for BS 8002 equation. A (degrees) Rounded Sub-angular. 2 Angular. B (degrees) Uniform Moderate grading.

8.1. What is meant by the shear strength of soils? Solution 8.1 Shear strength of a soil is its internal resistance to shearing stresses.

DYNAMIC ANALYSIS OF PILES IN SAND BASED ON SOIL-PILE INTERACTION

Shake Table Study of Soil Structure Interaction Effects in Surface and Embedded Foundations

THE STRUCTURAL DESIGN OF PILE FOUNDATIONS BASED ON LRFD FOR JAPANESE HIGHWAYS

Geophysical Site Investigation (Seismic methods) Amit Prashant Indian Institute of Technology Gandhinagar

Dynamic Soil Structure Interaction

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

Laboratory Testing Total & Effective Stress Analysis

EXTENDED ABSTRACT. Combined Pile Raft Foundation

SEISMIC RESPONSE OF INDUSTRIAL STRUCTURES CONSIDERING SOIL-PILE-STRUCTURE INTERACTION

The Ultimate Pile Bearing Capacity from Conventional and Spectral Analysis of Surface Wave (SASW) Measurements

NON LINEAR DYNAMIC RESPONSE VARIATION UNDER DIFFERENT SETS OF EARTHQUAKES

Effect of cyclic loading on shear modulus of peat

SHEAR STRENGTH OF SOIL UNCONFINED COMPRESSION TEST

TC211 Workshop CALIBRATION OF RIGID INCLUSION PARAMETERS BASED ON. Jérôme Racinais. September 15, 2015 PRESSUMETER TEST RESULTS

Soil Behaviour Type from the CPT: an update

VORONOI APPLIED ELEMENT METHOD FOR STRUCTURAL ANALYSIS: THEORY AND APPLICATION FOR LINEAR AND NON-LINEAR MATERIALS

Soil and Rock Strength. Chapter 8 Shear Strength. Steel Strength. Concrete Strength. Dr. Talat Bader May Steel. Concrete.

Liquefaction and Foundations

Evaluation of soil liquefaction using the CPT Part 2

Landslide FE Stability Analysis

SEISMIC BASE ISOLATION

Calculation and analysis of internal force of piles excavation supporting. based on differential equation. Wei Wang

SOIL SHEAR STRENGTH. Prepared by: Dr. Hetty Muhammad Azril Fauziah Kassim Norafida

EXAMPLE OF PILED FOUNDATIONS

Numerical Modeling of Interface Between Soil and Pile to Account for Loss of Contact during Seismic Excitation

On the Dynamics of Inclined Piles

ENCE 3610 Soil Mechanics. Site Exploration and Characterisation Field Exploration Methods

GEOTECHNICAL EVALUATION AND GEOTECHNICAL DESIGN PARAMETERS)

Small strain behavior of Northern Izmir (Turkey) soils

INFLUENCE OF SOIL NONLINEARITY AND LIQUEFACTION ON DYNAMIC RESPONSE OF PILE GROUPS

Influence of the Soil Structure Interaction on the Fundamental Period of Large Dynamic Machine Foundation

Evaluation of the Liquefaction Potential by In-situ Tests and Laboratory Experiments In Complex Geological Conditions

PILE FOUNDATION RESPONSE DUE TO SOIL LATERAL SPREADING DURING HYOGO-KEN NANBU EARTHQUAKE

Manual on Subsurface Investigations National Highway Institute Publication No. FHWA NHI Federal Highway Administration Washington, DC

Shear Strength of Soils

(C) Global Journal of Engineering Science and Research Management

Reinforced Soil Structures Reinforced Soil Walls. Prof K. Rajagopal Department of Civil Engineering IIT Madras, Chennai

Dynamic Analysis Contents - 1

NEW DOWN-HOLE PENETROMETER (DHP-CIGMAT) FOR CONSTRUCTION APPLICATIONS

Appendix J. Geological Investigation

Numerical simulation of inclined piles in liquefiable soils

Geotechnical Properties of Soil

TIME-DEPENDENT BEHAVIOR OF PILE UNDER LATERAL LOAD USING THE BOUNDING SURFACE MODEL

Pullout Tests of Geogrids Embedded in Non-cohesive Soil

DYNAMIC CHARACTERISTICS OF PILE GROUPS UNDER VERTICAL VIBRATIONS

Constitutive Model Input Parameters for Numerical Analyses of Geotechnical Problems: An In-Situ Testing Case Study.

Dynamic Response of EPS Blocks /soil Sandwiched Wall/embankment

Talić Z. et al: Geotechnical characteristics... Archives for Technical Sciences 2014, 11(1), 33-39

Numerical Investigation of the Effect of Recent Load History on the Behaviour of Steel Piles under Horizontal Loading

GEOTECHNICAL SITE CHARACTERIZATION

Table of Contents Chapter 1 Introduction to Geotechnical Engineering 1.1 Geotechnical Engineering 1.2 The Unique Nature of Soil and Rock Materials

Design Example 2.2. Pad foundation with inclined eccentric load on boulder clay

SHEAR STRENGTH OF SOIL

Dynamic Analysis of Pile Foundations: Effects of Material Nonlinearity of Soil

PLAXIS 3D FOUNDATION Validation Manual. version 1.5

Erratum. Chapter 4 - Earth and water pressure 26. Chapter Area loads. q a. c+d ϕ'/2. Piling Handbook, 9th edition (2016)

Conventional Field Testing & Issues (SPT, CPT, DCPT, Geophysical methods)

Transcription:

Soil-Structure dynamic interaction: application to design and construction of the facilities of a gas power plant Roma V., Locatelli L. Golder Associates (Italy) Bergamaschi M., Quadrelli D. Studio Ingegneri Associati Gadda Vigone Quadrelli (Italy) ABSTRACT This paper shows the different structural and geotechnical aspects of the design and the construction of the facilities of a gas power plant under static and dynamic loading conditions. The facilities comprehend a 50m high blow-down system, three compressor machines, a steel industrial superstructure and a reinforced concrete building. The plant is located in Sicily, a medium to high seismic zone of Italy, hence the soil-structure dynamic interaction needs to be considered. The loads acting on both the superstructure and the piled foundation system have been determined by means of a SSI analysis for the most sensitive and important structures, i.e. the 50m high blow-down system and the compressor machines. Keywords: soil-structure dynamic interaction, earthquake, vibrations, piled foundations, structural and geotechnical engineering 1 INTRODUCTION In common practice structural engineers use a detailed model for the superstructure and a simplified system for the ground, vice versa geotechnical engineers design the foundation system by means of a refined model for the ground, but assuming a single degree of freedom superstructure if not only the transferred static or inertial loads from the superstructure. In this paper a case history is documented (Locatelli & Roma, 2004) in which the soil-structure interaction between the ground and the superstructure has been considered, especially when dealing with particular structures, such as towers or vibrating machines subjected to dynamic loading (Barkan, 1962, Bowles, 1996, Gazetas, 1983, Wolf, 1985). 2 GEOLOGICAL AND GEOTECHNICAL CHARACTERISATION The gas power plant already exists (see figure 1) and belongs to ENI S.p.a. and additional facilities need to be constructed. The gas power plant is located in Gagliano Castelferrato (Enna, Sicily, Italy) on a floodplain of the stream Gagliano on a slightly inclined slope (i=10 ) from East towards West. The area is of medium to high seismicity and according to the new national seismic classification (OPCM 3274, 2003) the site is of type E and is located in zone of class II, which means a PGA=0.25g. Geotechnical investigations have comprised both in situ and laboratory tests: 7 boreholes: 5 down to a maximum depth of 20m and 2 to a maximum depth of 30m an array of seismic refraction and an array of SAW test (Spectral Analysis of Surface Waves) (Roma, 2001, 2004) 2 loading plate tests and standard penetration tests SPT 3 Piezometers Triaxial compression CIU and CD test under drained and undrained conditions Direct Shear test under drained conditions Unconfined compression test Atterberg limits and granulometry determination Edometer tests On the basis of the results of both the geotechnical investigations and the geological information three main geological units can be recognized from the ground level below: Alluvium deposit Weathered and plastic Varicolari clays Very stiff brown clays with blocks of quarzareniti (flysch Numidico)

Figure 1. Landscape with the gas power plant Table 1: Geotechnical units and soil characterisation Geotechnical unit Soil description γ (kn/m 3 ) φ ( ) c (kpa) 1 2 Superficial ground Grains into clayey, silty matrix 18.5 19 0 18.5 19 0 3 Weathered plastic clay 20 21 10 4 Stiff clay 20 24 15 5 Very Stiff clay 20 25 25 Following the geological events, the geological older varicolari clays are located at a smaller depth respect to the geological younger flysch clays, hence it is expected that the whole deposit be overconsolidated. This aspect has been confirmed by the laboratory tests performed on undisturbed samples of soil at different depths. In the smaller geotechnical spatial scale a more refined characterization can be made with respect to the geological characterization. The geotechnical units found during in situ investigations, are reported in table 1. The undrained shear resistance Cu has been determined based on laboratory tests as a linear function of the effective stress, which depends on stratigraphy, depth and water table position. Figure 2 reports the results of a laboratory CIU compression test on an undisturbed sample of the geotechnical unit 2 at a depth of 5m. Generally the water table has not been found during drilling, down to the maximum investigated depth of about 30m, except in a borehole where the water table position was found at a depth of about 12m. Anyway the cohesive nature of the soil, which tends to saturation after raining, suggests to consider the water table at ground level in the analysis. Table 2: Shear wave velocity and shear modulus at very small deformations Go profiles by SASW and seismic refraction tests Geote chnical unit Depth from g.l. (m) Vs (m/s) Vp (m/s) Go (MPa) 2 0 7 80 305 12 3-4 7 13 530 1425 560 4-5 13 20 515 2000 530 5 >20 900 2230 1620 3 DESCRIPTION OF THE FACILITIES AND THEIR FOUNDATION SYSTEM The facilities to be constructed consist of (see figure 3): a blow-down system high 50m and a base mat foundation realized by an inferior r.c. slab with dimensions 7.80m x 7.80mx 0.50m and by a superior r.c. hollow block, filled with gravel, with external dimensions 6.20m x 6.20m x 1.60m and lateral

walls with a thickness of 0.7m and a superior slab with a thickness of 0.50m; 3 r.c. foundations for the compressor machines realized by an inferior r.c. slab with dimensions 13.10m x 8.00m x 0.70m and by superior r.c. hollow block with external dimensions 9.70m x 2.60m x 1.50m and lateral walls with a thickness of 0.5m 0.7m and a superior slab with a thickness of 0.30m; a steel framed shed with dimensions 44.00m x 15.00m x 12.00m constructed to cover the compressors; a reinforced concrete structure with external dimensions 15.50m x 12.50m x 8.00m, realized to contain several electrical devices. deviatoric stress (kpa) CIU test in geotechnical unit 2 at z=5m 700 600 500 400 300 200 Sample # 3 100 Sample # 2 Sample # 1 0 0 2 4 6 8 axial deformation (%) Figure 2. CIU triaxial compression test on a sample of the geotechnical unit 2 For all the facilities reinforced concrete have been adopted. The foundation characteristics of each facility are described in table 3. Table 3: Foundation system under each facility Foundation Blowdown system Steel frame Compressors Concrete building Facility Mat with 8 Math with 12 Beams on pile Beams on D (m) L (m) test Nmax (ULS) (kn) 1.0 20 1 663 1.0 20 1 598 0.6 1.0 20-425 0.6 1.0 20 2 676 480 D, L = pile diameter and length; Nmax= design axial load at ULS. 4 DESIGN APPROACH Both a conventional approach and a complete SSI analysis have been considered for the design of the facilities under inertial loads. Also cinematic effects have been determined seperately. Blow-down system Steel frame compressors R. C. frame Figure 3. Section view of the new facilities to be constructed into the gas power plant.

The conventional approach, commonly used in practice for inertial loads, does not consider soilstructure dynamic interaction, since the superstructure is considered fixed at the base and the reactions at the fixed base are successively used as actions on the foundation system. Soil-structure dynamic interaction by means of FEM (Bowles, 1996) allows for a complete model of both the superstructure, the foundation system and the surrounding soil. (see figure 4 and figure 5). The interaction between the pile and ground has been modelled by means of dynamic Winkler s springs, which are characterized by an elasto-plastic behaviour. Both the limit yielding pressure p lim (equation 1) and the dynamic elastic stiffness k dynamic of the Winkler s springs (equation 2) have been calculated as a function of the undrained shear resistance of the soil Cu, when transient loading events, such as earthquakes occur. plim = 0.72 0. 9 Cu (Poulos & Davis, 1987) (1) k = η (Bowles, 1996) (2) dynamic k static E k static = (3) 2 ( 1 ν ) the dynamic factor η depends on the dimensionless frequency a 0 ω 0.5 D = V S (4) which contains information about the pile diameter D, the shear wave velocity of the soil Vs and the circular frequency ω of the external load (earthquake, wind, machines). E and υ are the Young modulus and the Poisson ratio of the soil. By comparing the two methods of analysis it has been observed that when using a conventional approach the stress level and the deformations of the structural elements (beams and columns) of the superstructure are approximately 30% lower with respect to the results obtained with a complete SSI analysis under the same soil and loading conditions. This means that using fixed constraints instead of the actual foundation system at the base of the superstructure may cause a significant underestimation of the safety level of the structure, especially when dealing with soft superficial soils. 5 NATURAL FREQUENCIES OF THE SOIL DEPOSIT Also the natural frequencies of both the ground and the foundation-superstructure system have been calculated, to assure that resonance phenomena will not occur for travelling shear S waves (fs) and superficial Rayleigh waves (f R ). f f S R VS = (5) 4h ( a + bj) Vs = (Roma et al., 2001) (6) H where a=-0.09, b=0.65 are two constants and j is the Rayleigh mode of reference. Two different situations have been considered: Case A) only the soil layer of soft clay (geotechnical unit 2) has been considered with Vs 1 =80 m/s and thickness h 1 =6.6m Case B) the first 30m of soil have been considered with an equivalent shear wave velocity Vs 30 = 251m/s, according to Eurocode 8. Table 4 reports the natural frequencies of the deposit for the cases A and B, when considering both vertically propagating shear waves (S) and Rayleigh waves (R) travelling on the free surface. The higher natural frequency of the soil deposit f site =6.8Hz has been compared with the natural frequencies of the whole system (superstructure and foundation system) f min_structure =10.9Hz (the lower frequency is the horizontal translational mode) and the operating frequencies of the compressors f exc =16Hz (lower frequency of exercise) (see table 5). It has been verified that resonant conditions do not occur with the soil deposit, since f exc /f site =2.36 and f min_structure /f site =1.61. Table 4: Natural frequencies of the soil deposit (type E according to OPCM 3274, 2003) Case Vs h fs f R (m/s) (m) (Hz) (Hz) A 80 6.6 3.0 6.8 B 251 30 2.1 4.7 h=thickness of the layer Table 5: Verification of no resonant conditions f_ecc (Hz) f_site (Hz) f_structure (Hz) 16 6.8 10.9

6 TESTING ON FULL SCALE PILES Figure 4. FEM for the soil-structure dynamic interaction between ground and compressors. After design of the 4 full scale tests have been prescribed on, which are representative of the different soil-foundation conditions. The loading test is increasing monotonic up to a value of 1.5 times the maximum expected load in exercise. Table 2 summarizes the location and the characteristics of the tested. Also in figure5 and figure 6 the test equipment and the loadsettlement curve are shown regarding the loading test on the pile # 5 of the blow-down system. In the 1st cycle and 2nd cycle of loading the exercise axial load Ne=432 kn and 1.5 Ne have been reached with the maximum settlements respectively of w1=0.29mm and w2=0.48mm. The residual settlements are around 0.1mm. The results of the loading test prove that soil-pile behaviour is essentially elastic under the exercise loading conditions. Figure 5. Plant of the piled foundation of the 3 compressors. Figures 6. Loading test on pile # 5 of the blow-down system.

650 Load (kn) Figure 7. Load-settlement curve from 2 cycles of loading on pile # 5 of the blow-down system. 7 CONCLUSIONS Settlements cycle 1 0.5 cycle 2 A methodological approach has been adopted for the design and the construction of the piled foundations of the facilities of a gas power plant under static loads and different types of dynamic loading (seismic, vibrations generated by machines). After the geological and geotechnical ground characterisation by means of a series of in situ and laboratory tests, soil-structure dynamical interaction has been considered to evaluate the loads on the superstructure and the foundation system of the most sensitive and important structures, i.e. the vibrating compressors and the 50m high blowdown system. A comparison between a complete SSI analysis with FEM and a simplified conventional approach with the superstructure fixed at the base reveals that with the simplified conventional method the safety level of the whole structure could be underestimated of about 30%, on average over all the structural elements. A series of loading tests on full scale has been prescribed to verify the correctness of the soil-pile behaviour predicted during the design phase. REFERENCES Barkan D.D. (1962) Dynamics of bases and foundations, McGraw-Hill (translated) Bowles J., (1996). "Foundation Analysis and Design." Mc Graw Hill. D.M. (1988) Norme tecniche riguardanti le indagini sui terreni e sulle rocce, la stabilità dei pendii naturali e delle scarpate, i criteri generali e le prescrizioni per la progettazione, l esecuzione e il collaudo delle opere di sostegno delle terre e delle opere di fondazione, 11 Marzo Eurocode 8 (2003) Design of structures for earthquake resistance. Part 5: Foundations, retaining structures and geotechnical aspects, December. Gazetas G. (1983) Analysis of machine foundation vibrations: state of the Art, Soil Dynamics and Earthquake engineering, Vol.2, n1 Lancellotta R. (1987) Geotecnica, Zanichelli Locatelli L., Roma V. (2004) Ampliamento dell impianto centrale a gas dell ENI S.p.a. a Gagliano (EN): Relazione tecnica delle fondazioni profonde area compressori, internal report Golder Associates M40056/0465/Dec.2004 OPCM 3274 20.3.2003: Primi elementi in materia di criteri generali per la classificazione sismica del territorio nazionale e di normative tecniche per le costruzioni in zona sismica Poulos H.G. e Davis E.H. (1987): Analysis and design of pile foundation, italian translation by Modica E.G., Flaccavio Editore s.r.l. Roma V. (2001) Soil Properties and Site Characterization by means of Rayleigh Waves Ph.D Dissertation, Politecnico di Torino (Italy) Roma V., Lancellotta R., Rix G.J. (2001) Rayleigh Waves in Horizontally Stratified Media: Relevance of Resonant Frequencies, WASCOM 2001 (Wave Stability in Continuous Media), Porto Ercole, June Roma V. (2004) "Dynamic Soil Identification by means of Rayleigh Waves", XI Italian Conference on Earthquake Engineering, Genova. Roma V. (1998) Attenuazione della risposta sismica di strutture su pali, translation: Mitigation of the seismic response of structures based on piled foundations Master Thesis, Technical University of Turin (Politecnico) Wolf (1985) Dynamic soil-structure interaction Prentice-Hall AKNOWLEDGMENTS The authors thank the owner ENI S.p.a. and the construction company Benelli Ravenna - Bonatti S.p.a. for permission to use the data contained in the paper.