MR Advance Techniques. Flow Phenomena. Class I

Similar documents
Introduction to MRI. Spin & Magnetic Moments. Relaxation (T1, T2) Spin Echoes. 2DFT Imaging. K-space & Spatial Resolution.

Contrast Mechanisms in MRI. Michael Jay Schillaci

Introduction to Biomedical Imaging

Chapter 24 MRA and Flow quantification. Yongquan Ye, Ph.D. Assist. Prof. Radiology, SOM Wayne State University

MRI in Practice. Catherine Westbrook MSc, DCRR, CTC Senior Lecturer Anglia Polytechnic University Cambridge UK. John Talbot MSc, DCRR

EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam

Correction Gradients. Nov7, Reference: Handbook of pulse sequence

A Study of Flow Effects on the Gradient Echo Sequence

Rad Tech 4912 MRI Registry Review. Outline of the Registry Exam: Certification Fees

NMR and MRI : an introduction

Fundamentals of MR Imaging

NMR/MRI examination (8N080 / 3F240)

Velocity Images. Phase Contrast Technique. G. Reiter 1,2, U. Reiter 1, R. Rienmüller 1

Tissue Characteristics Module Three

RADIOLOGIV TECHNOLOGY 4912 COMPREHENSEIVE REVIEW/MRI WORSHEET #1- PATIENT CARE AND SAFETY/PHYSICAL PRINCIPLES

Advanced Topics and Diffusion MRI

MRI Physics I: Spins, Excitation, Relaxation

Navigator Echoes. BioE 594 Advanced Topics in MRI Mauli. M. Modi. BioE /18/ What are Navigator Echoes?

Field trip: Tuesday, Feb 5th

Physics of MR Image Acquisition

Bioengineering 278" Magnetic Resonance Imaging" " Winter 2011" Lecture 9! Time of Flight MRA!

Background II. Signal-to-Noise Ratio (SNR) Pulse Sequences Sampling and Trajectories Parallel Imaging. B.Hargreaves - RAD 229.

Introductory MRI Physics

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

Part III: Sequences and Contrast

MRI at a Glance. Blackwell Science CATHERINE WESTBROOK. MSC DCRR CTC Director of Training and Education Lodestone Patient Care Ltd

FREQUENCY SELECTIVE EXCITATION

The physics of medical imaging US, CT, MRI. Prof. Peter Bogner

Introduction to MRI Acquisition

The NMR Inverse Imaging Problem

Tissue Parametric Mapping:

Magnetic resonance imaging MRI

The physics US and MRI. Prof. Peter Bogner

M R I Physics Course

Magnetic Resonance Imaging. Pål Erik Goa Associate Professor in Medical Imaging Dept. of Physics

Sequence Overview. Gradient Echo Spin Echo Magnetization Preparation Sampling and Trajectories Parallel Imaging. B.Hargreaves - RAD 229

Lecture k-space. k-space illustrations. Zeugmatography 3/7/2011. Use of gradients to make an image echo. K-space Intro to k-space sampling

Blood Water Dynamics

On Signal to Noise Ratio Tradeoffs in fmri

K-space. Spin-Warp Pulse Sequence. At each point in time, the received signal is the Fourier transform of the object s(t) = M( k x

G Medical Imaging. Outline 4/13/2012. Physics of Magnetic Resonance Imaging

Apodization. Gibbs Artifact. Bioengineering 280A Principles of Biomedical Imaging. Fall Quarter 2013 MRI Lecture 5. rect(k x )

EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 9 Solutions. Due April 29th, 2013

Magnetization Preparation Sequences

Basic p rinciples COPYRIGHTED MATERIAL. Introduction. Atomic s tructure

Outlines: (June 11, 1996) Instructor:

A Phantom Study of Intracranial CSF Signal Loss Due to Pulsatile Motion

Exam 8N080 - Introduction to MRI

Introduction to Magnetic Resonance Imaging (MRI) Pietro Gori

7.3.A. The expression for signal recovery is similar to that derived under exercise 7.2 and is given by:

Development of Phase Contrast Sequence

Applications of Spin Echo and Gradient Echo: Diffusion and Susceptibility Contrast

31545 Medical Imaging systems

Arterial Macrocirculatory Hemodynamics

Basic MRI physics and Functional MRI

Disclosures. MR Physics. Recipe to Creating Images without Radiation. MRI Physics. Vector Math. What s In an Image 12/21/2012. Siemens Medical Systems

BNG/ECE 487 FINAL (W16)

MRI in Review: Simple Steps to Cutting Edge Part I

Basis of MRI Contrast

Part II: Magnetic Resonance Imaging (MRI)

How is it different from conventional MRI? What is MR Spectroscopy? How is it different from conventional MRI? MR Active Nuclei

DETERMINATION OF MORTAR SATURATION METHODS BASED ON MRI SCANNING IMAGE

Nuclei, Excitation, Relaxation

Chapter 14:Physics of Magnetic Resonance

Chapter 26 Sequence Design, Artifacts and Nomenclature. Yongquan Ye, Ph.D. Assist. Prof. Radiology, SOM Wayne State University

MRS: IN VIVO SPECTROSCOPIC IMAGING MAIN POINTS

6/22/2011. RT 4912 Review. Rex T. Christensen MHA RT (R) (MR) (CT)

Basic Pulse Sequences II - Spin Echoes. TE=12ms TE=47ms TE=106ms TE=153ms UCLA. Radiology

Fundamental MRI Principles Module Two

Technical University of Denmark

Fundamental MRI Principles Module 2 N. Nuclear Magnetic Resonance. X-ray. MRI Hydrogen Protons. Page 1. Electrons

B4 Organising animals and plants. Student Book answers. B4.1 The blood. Question Answer Marks Guidance

Lecture 21. Nuclear magnetic resonance

Cambridge University Press MRI from A to Z: A Definitive Guide for Medical Professionals Gary Liney Excerpt More information

Magnetic Resonance Imaging

Pulse Sequences: RARE and Simulations

Worksheet for Exploration 15.1: Blood Flow and the Continuity Equation

RAD229: Midterm Exam 2015/2016 October 19, Minutes. Please do not proceed to the next page until the exam begins.

Renal perfusion measurement with Ultrasound Contrast Agents. Emilio Quaia. Department of Radiology University of Trieste

HY Ιατρική Απεικόνιση. Διδάσκων: Kώστας Μαριάς

Spin Echo Review. Static Dephasing: 1/T2 * = 1/T2 + 1/T2 Spin echo rephases magnetization Spin echoes can be repeated. B.Hargreaves - RAD 229

BME I5000: Biomedical Imaging

Nuclear Magnetic Resonance Log

2.1.1 A Brief History of NMR The conception of NMR sprouted after the Pauli s prediction of nuclear spin in

BASIC MRI PHYSICS SPIN GYMNASTICS Don Plewes PhD, Walter Kucharczyk MD

Effect of Bulk Tissue Motion on Quantitative Perfusion and Diffusion Magnetic Resonance Imaging *

MRI Physics II: Gradients, Imaging. Douglas C. Noll, Ph.D. Dept. of Biomedical Engineering University of Michigan, Ann Arbor

MRI based quantification of outflow boundary conditions for wall shear stress calculations in stenosed human carotid bifurcations

Nuclear Magnetic Resonance Imaging

10 0 = 1 1 second. Chapter 1

Biophysical Chemistry: NMR Spectroscopy

Magnetic Resonance Imaging

NMR Imaging in porous media

Principles of Magnetic Resonance Imaging

Introduction to the Physics of NMR, MRI, BOLD fmri

Homework Problem Set 10 Iverson CH320M/CH328M Due Monday, December 10

Relaxation times in nuclear magnetic resonance

Me myself and MRI: adventures in not understanding nuclear physics.

COPYRIGHTED MATERIAL. Production of Net Magnetization. Chapter 1

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Transcription:

MR Advance Techniques Flow Phenomena Class I

Flow Phenomena In this class we will explore different phenomenona produced from nuclei that move during the acquisition of data. Flowing nuclei exhibit different contrast characteristics from their neighboring stationary nuclei, and originate primarily from hydrogens in blood and CSF.

Types of flow There are four principal types of flow: Laminar flow Turbulent flow Vortex flow Spiral flow Stagnant flow

Laminar Flow Laminar flow also known as parabolic flow is flow that is at different but consisted velocities across a vessel. The flow in the center of the vessel move faster than at the vessel walls, where resistance slows down the flow. However, the velocity difference across the vessel is constant.

Spiral Flow Spiral flow is where the direction of the flow is spiral.

Vortex Flow Vortex flow is flow that is initially laminar but then passes through a stricture or stenosis in the vessel. Flow in the center of the lumen has high velocity, but near the walls, the flow spiral.

Turbulent Flow Turbulent flow is flow at different velocities that fluctuates randomly. The velocity difference across the vessel changes erratically.

Stagnant flow Stagnant flow is describe as no flow circulation due to blockage of a blood vessel

Blood Flow Velocity Blood flow is faster in arteries and slower in veins. The velocity will vary depending on the proximity to the heart and the caliber of the blood vessel. The definition of blood flow velocity as given in the medical dictionary is, "a value equal to the total volume flow divided by the cross-sectional area of vascular bed". Velocity of blood is measured in cm/s. Flow Velocity = Flow Volume / Vessel Area

Flow Velocity Blood Vessel Aorta Pulmonary Artery Inferior Vena Cava Superior Vena Cava Portal Vein Carotid Artery Middle Cerebral Artery Flow Velocity 92 cm/sec 63 cm/sec 30-45 cm/sec 10-35 cm/sec 20 cm/sec 29-178 cm/sec 58.3 cm/sec

Abdominals Blood Vessels Abdominal Aorta Inferior Vena Cava (IVC) Blood Vessel Aorta IVC Flow Velocity 92 cm/sec 30-45 cm/sec

Flowing Protons There two types of signal intensities from flowing protons: Dark / Hypo-intense / Black / signal void / signal loss Bright / Hyper-intense / enhance

Flow Phenomena The motion of flowing nuclei causes several artifacts effects on the image: Entry Slice Phase misshaping Signal Void

Flow Phenomena The causes of flow artifact are collectively know as Flow Phenomena. The principal Flow phenomena are: Time of flight Entry slice Intra-voxel dephasing

Stationary Protons Remember that excitation pulses are slice selected 90º

Stationary Protons To produce a signal the protons must receive a excitation and a rephasing pulse. 90º ½ TE (20 ms) 180º

Stationary Protons If protons receive both excitation pulses, they will have high signal intensity on the image. 90º 180º

Time of Flight Phenomenon If the nucleus receive only one of the two pulses, it does not produce signal. This is call Time of Flight Phenomenon (TOF). 90º 180º

Time of Flight Phenomenon in SE Stationary nucleus will received both the excitation pulse plus the rephasing pulse. As result stationary protons will produce signal, but flowing protons will not produce any signal. 90º ½ TE (20 ms) 180º

TOF The TOF phenomenon depends on the following parameters: Velocity of Flow (intrinsic) TE (extrinsic) Slice Thickness (extrinsic)

Time of flight effects

TOF Effects Velocity of flow: as the velocity of the flow increases the time of flight effect increases due to protons will move faster and stay less time within the slice. This is called high velocity signal loss. 90º 180º ½ TE Rapid flow

TOF Effects As the velocity of the flow decreases, a higher proportion of flowing nuclei are present in the slice for both 90 and 180 pulses. As the velocity decreases the TOF decreases. This is called flow related enhancement. 90º 180º ½ TE Slow flow

90º 180º 90º 180º

TOF Effects TE: as the TE increases, a higher proportion of flowing protons have exited the slice between the excitation pulses, and the TOF effect increases. 90º 180º ½ TE ½ TE

TOF Effects TE: as the TE decreases, a smaller proportion of flowing protons have exited the slice between the excitation pulses, and the TOF effect decreases. 90º 180º ½ TE ½ TE

90º 180º 90º 180º

TOF Effects As the thickness of the slice decreases, the nuclei are more likely to receive only one pulse and the signal void increases. As the slice thickness is decreased TOF increases. 90º 180º ½ TE

TOF Effects Slice thickness: for a given constant flow velocity, protons take longer to travel through a thick slice compared with a thin slice. Therefore in a thick slice nuclei are more likely to receive both 90 and 180 pulses. In a thick slice the time of flight effect decreases. 90º 180º ½ TE

90º 180º 90º 180º

Time of Flight Phenomenon in GRE In gradient echo pulse sequences each slice is selectively exited by the pulse, the rephasing gradients applied to the entire body. Therefore, a flowing proton that receives an excitation pulse is rephased regardless of its slice position and produces a signal. 90º ½ TE (20 ms)

90º 180º 90º

Time of Flight Phenomenon in GRE In addition, the very short TR usually associated with gradient echo sequences tends to saturate stationary protons which receive repeated pulses so that flowing protons appear to have a higher signal intensity. GRE pulse sequences are often said to be flowsensitive.

Flow related enhancement increases as: Velocity of flow TE Decreases Decreases Slice thickness Increases

High velocity signal void increases as: Velocity of flow TE Increases Increases Slice thickness Decreases

Entry Slice Phenomenon The entry slice phenomenon is related to the excitation history of the protons. 12

Entry Slice Phenomenon The rate of which the flowing nuclei receive the excitation pulses determines the magnitude of the entry slice phenomenon. Any factor that affects the rate at which a nucleus receives repeated pulses affects this phenomenon.

Entry Slice Phenomenon The magnitude of the entry slice phenomenon depends on four factors: TR Slice thickness Velocity of flow Direction of flow 1 2 3

Entry Slice Phenomenon & TR 90º TR 90º TR 90º 1 2 3 As the TR Increases the Entry Slice Phenomenon also Increases

Entry Slice Phenomenon & TR 90º TR 90º TR 90º TR 90º TR 90º TR 90º 1 2 3 As the TR Decreases the Entry Slice Phenomenon Decreases

Entry Slice Phenomenon & TR 90º TR 90º TR 90º 1 2 3 1 2 3 90º TR 90º TR 90º TR 90º TR 90º TR 90º 1 2 3

Short TR Long TR 1 2 3 4 5 1 2 3 4 5

Entry Slice & Slice Thickness As the slice thickness increases the entry slice phenomenon decreases. Since slices are thicker entry slice will be sees in less slices when thicker slices are used.

Thicker Slice Thin Slice 1 2 3 4 1 2 3 4 5 6 7 8

Entry Slice & Slice Thickness As the velocity of the flow increases the entry slice phenomenon increases. When flowing protons move faster they receive less pulses and take longer to saturate.

Fast Flowing Protons Slow Flowing Protons 1 2 3 4 5 1 2 3 4 5

Entry Slice Phenomenon Direction of flow: Flow that is in the same direction as the slice acquisition Co-current flow. 1 2 3 Flow that is in the opposite direction of to the slice acquisition is called counter-current flow. 3 2 1

Entry Slice Phenomenon Co-current flow: The flowing nuclei are more likely to receive repeated pulses as they move from slice to the next. Protons become saturated relatively quickly, and so the entry slice phenomenon decreases rapidly. 1 2 3 4

Entry Slice Phenomenon Flowing protons stay fresh, as when they enter a slice they are less likely to have received previous excitation pulses. The entry slice phenomenon does not decrease rapidly, and may still be present in all the slices. 4 3 2 1

Intra-Voxel Dephasing Protons that are not under a gradient magnetic field have the same precessional frequency and the same phase within a Voxel.

Intra-voxel dephasing Protons under a gradient magnetic field will result in a difference in their precessional frequency. The phase encoding gradient is utilize to produce this change and dephase the protons.

Flowing protons are adjacent to stationary protons in the voxel. During the application of the phase encoding gradient, flowing protons move under the gradient altering their frequency. When the gradient is turn off, flowing protons acquire a different phase compared to the stationary ones.

Intra-voxel dephasing Therefore nuclei within the same voxel are out of phase with each other, which results in a reduction of total signal amplitude from the voxel. This is called intra-voxel dephasing. Flow Flow

Intra-voxel dephasing When the net magnetization of flowing protons is phase shifted, the signal generated by the net magnetization of protons is mismapped and place elsewhere along the phase encoding direction of the image. When this occurs, the vessel on the resulting image appears dark (no signal) or an artifact called flow artifact. Flow Artifact.

Phase Encoding Gradient 90º

Intra-Voxel Dephasing Factors Affecting Intra-Voxel Dephasing Velocity of the Flow TE Voxel size The amplitude of the Phase Encoding Gradient

Intra-Voxel Dephasing Velocity of the Flow: as the velocity of the flow increases the intra-voxel dephasing also increases.

Intra-Voxel Dephasing TE: as the TE increases the intra-voxel dephasing increases). 90º 180º 90º 180º

Intra-Voxel Dephasing Voxel size: as the Voxel size increases the intra-voxel dephasing increases. Increase Slice Thickness Increase FOV Decrease Matrix

Intra-Voxel Dephasing PES: as the phase gradient increases the intra-voxel dephasing also increases.

Flow Phenomena Compensation There are three methods used to compensate for the flow phenomena. Even echo rephasing Gradient moment nulling Spatial pre-saturation

Even Echo Rephasing Even-echo rephasing is a flow phenomenon that is observed in SE images in which multiple evenly spaced echoes (e.g., 25/50/75/100) have been acquired. For blood flowing at constant velocity in such an environment, phase dispersion is lower on the evennumbered echoes (i.e., 50/100) than on the odd echoes (i.e., 25/75). TE 25 TE 50 TE 75 TE 100

Gradient Moment Nulling Gradient moment nulling also known as flow compensation (Flow Comp) technique compensates for the altered phase values of the protons by applying an additional gradient to correct the altered phases back to their original values.

Gradient moment nulling technique is achieved by the frequency or the slice select gradient. These gradients alter the polarity from negative to positive (Balance Gradient Echo). PES 25% 25% + + 50%

Gradient Moment Nulling Gradient moment nulling assures that the flowing protons are in phase with the stationary protons at the time of the echo; this will result in a bright signal from flowing protons without artifact.

Phase Encoding Gradient 90º

Phase Encoding Gradient 25% 25% + 50% + 90º

Gradient Moment Nulling Since gradient moment nulling technique uses extra gradients, it will force an increases of the minimum TE. 10 TE No gradient moment nulling application 15 TE Gradient moment nulling application

As a result of increasing the TE, fewer slices may be available for a given TR or the TR and therefore the scan time may be automatically increased. No gradient moment nulling application 500 TR Slice 1 Slice 2 Slice 3 Slice 4 Gradient moment nulling application 600 TR Slice 1 Slice 2 Slice 2 Slice 2

Spatial Pre-Saturation Bands Spatial Pre-saturation bands also known as, Pre-Sats or Sat Bands, are used to saturate specific areas within the image. Pres-Sats can be used to: Nullify the signal from flowing nuclei: Minimize Entry Slice Minimize TOF Nullify signal from moving structures or undesired anatomy within the FOV.

Pre-Saturation Bands Pre Sats deliver a 90º pulse to a volume of tissue that is desired to eliminate. Pre sat Pulse 90 90 180

GRE

GRE

Slice Pre Saturation Band

Pre Saturation Band Sat Band Slice Sat Band

Pre Saturation Band Sat Band Slice Sat Band

Spatial Pre-Saturation To be effective, presaturation bands should be placed between the flow and the slice been acquired. Signal from flowing protons entering the slice will be nullified. Pre-saturation band

Pre-Saturation bands are use to reduce flow artifact Pre-saturation band Pre-saturation band

Pre-sat used to reduce entry slice phenomenon Pre-saturation band

Spatial pre-saturation pulses can be brought into the FOV itself. This permits artifacts producing areas such as pulsation, breathing, cardiac, peristaltic to be pre-saturated so that the phase misshaping can be reduced.

Spatial Pre-Saturation The use of pre-saturation pulses will increase the deposition on the patient (SAR), which may increase heating effects. The use of pre-saturation pulses may also decreases the number of slices available Pre sat 90 90 180 90 90 180 No pre sat 90 180 90 180

Pre-Sat The use of pre-saturation bands cam be used to limit our view to either the arteries or the veins.

Pre-saturation band

Blood Flow Enhancement GRE Counter-current flow Flow Comp Short TE Signal Void Spin Echo GRE Sat Bands