Strain and Displacement Monitoring of a Quay Wall in the Port of Genoa by means of Fibre Optic Sensors

Similar documents
Fatigue of stay cables inside end fittings high frequencies of wind induced vibrations

Displacement Measurements in the Cryogenically Cooled Dipoles of the New CERN-LHC Particle Accelerator

MODAL IDENTIFICATION AND DAMAGE DETECTION ON A CONCRETE HIGHWAY BRIDGE BY FREQUENCY DOMAIN DECOMPOSITION

SEISMIC PERFORMANCE OF URBAN, RECLAIMED AND PORT AREAS -FULL SCALE EXPERIMENT USING BLAST TECHNIQUE. Takahiro SUGANO 1) and Eiji KOHAMA 2)

Electrolytic Tiltmeter Temperature Coefficients: Source, Definition and Use to Improve Accuracy

New concept of a 3D-probing system for micro-components

RELIABILITY OF COMPOSITE STRUCTURES - IMPACT LOADING -

Dynamic damage identification using linear and nonlinear testing methods on a two-span prestressed concrete bridge

Structural Analysis Lab

SYSTEM IDENTIFICATION & DAMAGE ASSESSMENT OF STRUCTURES USING OPTICAL TRACKER ARRAY DATA

1 Introduction. This brief chapter introduces the subject of Solid Mechanics and the contents of this book

Model tests and FE-modelling of dynamic soil-structure interaction

Effects of Ice Loads on the Confederation Bridge

Numerical Modelling of Dynamic Earth Force Transmission to Underground Structures

Thermal movements of the Existing Gateway Bridge

Reliable Condition Assessment of Structures Using Uncertain or Limited Field Modal Data

EVALUATION OF THE ENVIRONMENTAL EFFECTS ON A MEDIUM RISE BUILDING

7 SHM and Adaptivity Concepts in the Reduction of Risks Associated to Structural Failures

FLEXIBILITY METHOD FOR INDETERMINATE FRAMES

Contribution of Norwegian partners (Aanderaa Data Instruments and NIVA) to Safeport project ( ). Final report

Monitoring based weak point determination of a steel bridge s torsional bracings with regard to fatigue threat

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

ANALYSIS OF IRREVERSIBLE DISPLACEMENTS IN MULTIPLE ARCH CONCRETE DAM USING PRINCIPAL COMPONENT ANALYSIS

Marine Mammal Observer Report

Effective stress analysis of pile foundations in liquefiable soil

APPLICATIONS OF HYDROSTATIC LEVELING IN CIVIL ENGINEERING

COPPER FOR BUSBARS CHAPTER 4: SHORT-CIRCUIT EFFECTS

Transactions on Modelling and Simulation vol 16, 1997 WIT Press, ISSN X

BEHAVIOUR OF INFLATED FABRIC BEAMS AT MEDIUM PRESSURES

Analysis of Interest Rate Curves Clustering Using Self-Organising Maps

Displacement and Settlement Monitoring in Large Geotechnical Structures with a Novel Approach to Distributed Brillouin Sensing

Only for Reference Page 1 of 18

CONTRIBUTION TO THE IDENTIFICATION OF THE DYNAMIC BEHAVIOUR OF FLOATING HARBOUR SYSTEMS USING FREQUENCY DOMAIN DECOMPOSITION

Contribution of new technologies for the monitoring of hydraulic plants: the EDF experience

Seismic design of bridges

FIS Specifications for Flex Poles (Edition May 2008) Original Text: German

NUMERICAL SIMULATION OF THE NON LINEAR BEHAVIOUR OF REINFORCED CONCRETE STRUCTURES

IOMAC' May Guimarães - Portugal RELATIONSHIP BETWEEN DAMAGE AND CHANGE IN DYNAMIC CHARACTERISTICS OF AN EXISTING BRIDGE

TIME-DOMAIN OUTPUT ONLY MODAL PARAMETER EXTRACTION AND ITS APPLICATION

RESILIENT INFRASTRUCTURE June 1 4, 2016

Design of Earthquake-Resistant Structures

Department of National Defence B-Jetty Reconstruction

Eurocode 8 Part 3: Assessment and retrofitting of buildings

PLEASURE VESSEL VIBRATION AND NOISE FINITE ELEMENT ANALYSIS

MEASUREMENT OF LOADS EXERTED BY SEA ICE ON THE QUAY AT KAPP AMSTERDAM ON SVALBARD

Cross Directional Control

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

Damage detection in plate-like structures using High-Order mode shape derivatives

Dynamic Properties of a Tall Reinforced Concrete Tower with Tuned Liquid Dampers

INTERNAL STRAIN MEASUREMENTS IN CFRP PLATES SUBJECTED TO IMPACT LOAD USING FBG SENSORS

Data Verification, Analytics and Visualization

Design of Safety Monitoring and Early Warning System for Buried Pipeline Crossing Fault

Development of ground based laser interferometers for the detection of gravitational waves

Lateral impact loading and snap-back testing to estimate linear and nonlinear dynamic response of near-shore piles

Geotechnical Monitoring for Safe Excavation of Large Rock Cavern: A Case Study

Forces on piles preventing debris slope slips

Design issues of thermal induced effects and temperature dependent material properties in Abaqus

ROBUST VIRTUAL DYNAMIC STRAIN SENSORS FROM ACCELERATION MEASUREMENTS

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Modal Analysis. Werner Rücker. 6.1 Scope of Modal Analysis. 6.2 Excitation of Structures and Systems for Modal Analysis

D DAVID PUBLISHING. Port and Marine Structures Made of Sheet Piling with Staggered Toe. 1. Introduction. 2. Design Approach and Main Dependencies

EddyMax Tube Inspection

MECHANICS OF MATERIALS. Prepared by Engr. John Paul Timola

EXPERIMENTAL EVALUATION OF MODAL PARAMETER VARIATIONS FOR STRUCTURAL HEALTH MONITORING

If you take CT5143 instead of CT4143 then write this at the first of your answer sheets and skip problem 4 and 6.

EA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE

Light, Electricity and Liquids. By Vitaliy Zamsha and Vladimir Shevtsov

MODELING AND FEM ANALYSIS OF DYNAMIC PROPERTIES OF THERMALLY OPTIMAL COMPOSITE MATERIALS

+ + ( indicator ) + (display, printer, memory)

VIBRATION MEASUREMENT OF TSING MA BRIDGE DECK UNITS DURING ERECTION

Finite Element Analysis of FRP Debonding Failure at the Tip of Flexural/Shear Crack in Concrete Beam

SEISMIC BASE ISOLATION

Chapter 3. Experimentation and Data Acquisition

Modeling and Monitoring of Damage in Grouted Joints

Damage detection using output-only measurement by indirect approach

The CLIC active prealignment studies H. MAINAUD DURAND, T. TOUZE CERN

Harmonized European standards for construction in Egypt

Damage detection of shear connectors in composite bridges under operational conditions

Dessi, D., D Orazio, D.

VERIFICATION OF MATERIAL PARAMETERS OF EARTHEN DAMS AT DIAMOND VALLEY LAKE USING GEODETIC MEASUREMENTS

DETERMINATION OF EI FOR PULTRUDED GFRP SHEET PILE PANELS. Abstract

WATERCOURSE HARNESSING BANK EROSION AND CONSOLIDATION

22 Which of the following correctly defines the terms stress, strain and Young modulus? stress strain Young modulus

Bridge deck modelling and design process for bridges

1. ARRANGEMENT. a. Frame A1-P3. L 1 = 20 m H = 5.23 m L 2 = 20 m H 1 = 8.29 m L 3 = 20 m H 2 = 8.29 m H 3 = 8.39 m. b. Frame P3-P6

Special edition paper

Optical Techniques for Gravitational-Wave Detection

Performance evaluation of smart prefabricated concrete elements

Structural System Identification (KAIST, Summer 2017) Lecture Coverage:

ERROR SOURCE IDENTIFICATION AND STABILITY TEST OF A PRECISION CAPACITANCE MEASUREMENT SYSTEM

twenty one concrete construction: shear & deflection ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2014 lecture

COEFFICIENT OF DYNAMIC HORIZONTAL SUBGRADE REACTION OF PILE FOUNDATIONS ON PROBLEMATIC GROUND IN HOKKAIDO Hirofumi Fukushima 1

THE ALIGNMENT OF THE LHC DURING THE SHUT-DOWN D. Missiaen, CERN, Geneva, Switzerland. Fiducialisation

Dynamic behaviour of a steel plate girder railroad bridge with rail joints

Concept Testing of a Simple Floating Offshore Vertical Axis Wind Turbine

Effect of tire type on strains occurring in asphalt concrete layers

A STUDY ON DAMAGE TO STEEL PIPE PILE FOUNDATION ON RECLAIMED LAND DURING HYOGO-KEN-NANBU EARTHQUAKE

DYNAMIC INVESTIGATIONS ON REINFORCED CONCRETE BRIDGES

WHAT SEISMIC HAZARD INFORMATION THE DAM ENGINEERS NEED FROM SEISMOLOGISTS AND GEOLOGISTS?

SERVICEABILITY LIMIT STATE DESIGN

Transcription:

2nd ENPC European Conference, 3-6.7.2, Champs-sur-Marne France Strain and Displacement Monitoring of a Quay Wall in the Port of Genoa by means of Fibre Optic Sensors Andrea DEL GROSSO Daniele INAUDI + Francesca LANATA Abstract. In the framework of a large-scale monitoring programme conducted by the Port Authority of Genoa, the east quay wall of the San Giorgio pier has been equipped with an array of SOFO fibre optic sensors for continuous monitoring. The system is in operation since fall 1999, and the paper is intended to present the first analyses and interpretations performed on the monitoring data. Correlation of raw data and curvature analysis to environmental conditions is also presented. Key words. Deformation sensors, Fibre optic sensors, Long-term monitoring, Port structures. 1 Introduction A large-scale monitoring programme is being conducted by the Port Authority of Genoa to assess safety and degradation of existing structures and to keep records of the effects of service conditions as well as of the effects of retrofitting activities. In the framework of this programme, the first realisation has been the installation of a monitoring system composed by more than 6 SOFO fibre optic long-base sensors along the east quay wall of the San Giorgio pier. Originally designed for detecting possible disruption of the wall caused by nearby dredging, the system will remain in place for a long-term monitoring experiment. The system is operational since fall 1999, and analysis and interpretation of the first series of data is presently under way. Data show to be reach of information concerning the real structural behaviour but recognition of the mechanical phenomena taking place in the structure is proving to be a challenging problem. Attempting to correlate simple inputs to a characteristic structural response, environmental temperature variation has been recognised to be the leading cause of structural deformation. In the paper, the approaches to data analysis and interpretation that have been applied yet are presented and discussed, together with their correlation to temperature data. As a conclusion, strategies for the development of the system and further processing of the data are discussed. Department of Structural Engineering, University of Genoa, Via Montallegro 1, I-16145 Genoa, Italy, http://www.unige.it, delgrosso@diseg.unige.it + SMARTEC S.A., Via al Molino 6, CH-6916 Grancia, Switzerland, http://www.smartec.ch, inaudi@smartec.ch

2 Measuring principles of the SOFO system SOFO [1] sensors are fibre optic sensors, able to detect deformations between any two points of a structure. This method has the advantage of allowing the measure of small deformations with very high precision (2 microns independently on the base length) over long periods of observation and, in addition, allows continuous and automatic monitoring of internal strains with a very good spatial resolution. These sensors are based on low coherence interferometry principles [2], giving high sensitivity non -incremental measures, without the need of continuous connection with the reading unit. A sensor is composed by two optical fibres inside a protection tube; one of the fibres is connected to the structure at both ends and the other one serves as a reference fibre, to compensate temperature effects. Measuring takes place through a coupled path interferometer, composed by a first interferometer measuring the difference between the optical path in the two fibres, and by a second one that translates the first interferogram into a displacement. The system is insensitive to external environmental disturbances like temperature, eddy currents, electromagnetic fields, corrosion, humidity and vibrations [3]. 3 Description of the monitoring project The San Giorgio pier is used for coal import and it has been recently subjected to a retrofitting programme, partly under way. The facility has been realised in the 2's and the vertical walls delimiting the quays are made of heavy concrete blocks; more recently, a further section has been added to the pier in order to increase berthing space and actually the pier measures 4 metres in length. Planned developments consist in dredging of the east basin from the actual 11 m to a water depth of 14 m, to allow berthing of bigger ships: this work has been planned for 21, and has required the strengthening of the east wall (Figure 1). Retrofitting of the wall has been performed in 1998; to avoid disruption of the wall during dredging, the structure has been underpinned with jetgrouting columns up to the depth of 18 m, and the blocks have been connected by means of vertical steel rods. Stability has been improved with permanent active tendons installed along the entire length of the pier. After execution of the consolidation works, the east wall has been equipped with a system of sensors in order to study the structural movements over a long period of time [4]. Monitoring has the objective of detecting deviations from normal structural behaviour, that may indicate a state of damage in the structure. Therefore, monitoring is organised in distinct phases: the first phase, before dredging operations, has the aim of determining what a normal structural behaviour can be; a second phase, during dredging, will be intended to detect potential damaging of the wall caused by the works and, finally, a third phase will involve health monitoring in the long term. The quay wall has been equipped with 72 SOFO sensors (67 of them continuously functioning), installed in such a way to have 3 sensors for each measuring section (Figure 1). All sensors have an active length of 1 metres; sensors have been positioned at the 3 vertices of the service gallery located in the crown blocks, except in the last extension part, where no gallery was built: therefore in the

last 5 sections only a pair of sensors have been installed in the upper surface of the crown block, underneath the pavement. Cabling of sensors has been organised in three groups (A,B, C, starting from the sea side), each one controlled by a junction box collecting 24 optical cables. The junction boxes are in turn connected to the reading unit by means of cables located in an underground duct. The reading unit is connected to the sensors through a programmable optical switch. Data are collected and stored in a computer database (SOFODB). In the next future, the reading unit will be connected to the Port of Genoa Information Network and the data base will be made available on-line. 2,9 m 2 3 1 1, 2, 3 sensor locations 11 m 14 m Figure 1: quay wall cross-section; strengthening works and sensor locations. 4 Data analysis and interpretation SOFO sensors have been extensively applied in the monitoring of bridge girders in Switzerland. To carry out interpretation of the readings and correlation with the mechanical behaviour of the structure, a computer method has been implemented at IMAC, Polytechnic of Lausanne. The algorithm, named SPADS, has been successfully tested both in laboratory experiments and in the field. According to this algorithm, developed by S. Vurpillot [5], the structure is subdivided into macro-elements, each one containing several cells in which the sensors are installed. Readings are collected through data acquisition campaigns. From the data of each campaign, an average curvature is computed for every cell, both in the vertical (Cz) and in the horizontal (Cy) planes. Computation is performed from the equation of plane deformation for two-way bending, using the sensor position matrix X and the measurement matrix Q: c (1) T a ( ) 1 = X X X Q b T C C z y b = L cells a = L cells (2)

where a,b,c are the equation coefficients. A polynomial fitting of the curvatures for each cell is then computed for every macro-element: (3) ( ) P x = a x n n i=1 In the case of displacement analysis for beams, double integration of these polynomials gives the deformed shape of the structure. This procedure is not completely applicable in the case of the quay wall, because it does not behave as a flexural element. However, the concepts of macro-elements and cells have been retained in data analysis, to transform sensor strain data into curvatures. After a few month, needed for the tuning of the system, the data have been permanently stored in the data base starting from 3 November 1999; acquisition campaigns have been programmed four times a day, each campaign elapsing 15 minutes to completion. Monitoring has been therefore addressed to characterise a long-term structural response. It is planned to analyse short-term phenomena, like crane operations, at a later stage. For the analysis of the data, the structure has been divided into 24 cells. The analysis of raw data has shown that the 3 sensors included in each standard cell give very similar relative displacements during time, with differences of the order of 1mm/1, i.e. of the same order of magnitude of the sensor precision. Among the various environmental sources causing long-period displacement of the wall, it has been found that temperature is playing the most important role. No apparent influence of the amount of coal stored in piles on the quay has been found. Correlation to environmental temperature has been therefore studied to a greater extent. In all the cells, it has been apparent that response to environmental temperature variations is delayed by a few days, due to the thermal inertia of such a massive structure. Sensor readings can be put in strict correlation with temperature variations, but different sections may respond to temperature in a different way. In particular, cells containing joints in the crown blocks give responses out-of-phase with respect to temperature variation, while monolithic cells give responses in-phase. The plots in Figure 2 and 3 show the different behaviour of the two types of cells. The difference is visible considering biweekly thermal variations as well as in the complete observation period (winter cycle and beginning of summer cycle). The analysis has been repeated in terms of curvatures. The horizontal and the vertical curvature have been determined applying equations (1) and (2) in a simplified form, because each cell contains only three sensors at the corners of a triangle. i i

Section C4 Displacement [mm].8.6.4.2 Sensor C41 Sensor C42 Sensor C43 3 25 2 15 1 5 T [degree Celsius/1] -.2 -.4 6/12/99 26/12/99 15/1/ 4/2/ 24/2/ 15/3/ 4/4/ 24/4/ 14/5/ 3/6/ 23/6/ -5 Figure 2: time-strain-temperature plot for a section in-phase with thermal variations. Section C5.5 3.4 25 Displacement [mm].3.2.1 -.1 2 15 1 5 T [degree Celsius/1] -.2 -.3 -.4 Sensor C51 Sensor C52 Sensor C53 6/12/99 26/12/99 15/1/ 4/2/ 24/2/ 15/3/ 4/4/ 24/4/ 14/5/ 3/6/ -5 23/6/ Figure 3: time-strain-temperature plot for a section out-of-phase with thermal variations. Curvatures have also been correlated to temperature variations. In terms of curvatures, the response of the structure is smoother but the most important information are retained. In particular, the response of a cell is still influenced by the presence of joints, but no clear information on discontinuity is detectable from the curvature plots. Figures 4 and 5 illustrate the plots of the time history of the curvature in two typical sections, compared with the time history of the environmental temperature. Time-delay due to the thermal inertia of the structure is clearly visible from the plots.

Curvature Cy Section A8 8 7 Curvature 3 25 6 Cy [1/mm] 5 4 3 2 1 2 15 1 5 T [degree Celsius/1] -1 6/12/99 26/12/99 15/1/ 4/2/ 24/2/ 15/3/ 4/4/ 24/4/ 14/5/ 3/6/ 23/6/ -5 Figure 4: time-curvature-temperature plot. Curvature Cz Section B2 1 3 5 25 Cz [1/mm] -5-1 -15 2 15 1 5 T [degree Celsius/1] -2-25 Curvature 6/12/99 26/12/99 15/1/ 4/2/ 24/2/ 15/3/ 4/4/ 24/4/ 14/5/ 3/6/ -5 23/6/ Figure 5: time-curvature-temperature plot. Since thermal effects have resulted to be the most important factor influencing the monitored response of the quay wall, more detailed analyses have been carried out. In particular, the comparisons have been repeated taking into consideration only the campaigns performed at the sam e hours. These comparisons have led to observe that, during the day, anomalies appear in the correlation between temperature variations and observed response. An attempt has been made to attribute such disturbances in the response to terminal operations. However, no correlation has been found between such disturbances and the presence of ships at the berths. Figure 6 shows a typical plot of the curvature versus time and temperature, derived from the readings of a cell taken at the same time of the day.

Section C6 h 5. 25 2 Cz Section C6 25 2 Cz [1/mm] 15 1 5 15 1 5 T [degree Celsius/1] -5-1 6/12/99 26/12/99 15/1/ 4/2/ 24/2/ 15/3/ 4/4/ 24/4/ 14/5/ 3/6/ 23/6/ -5 Figure 6: time-curvature-temperature plot for the same hour. To conclude the presentation of curvature analysis, a global view of the quay wall response, in terms of curvature as a function of space and time, is presented in Figure 7. It is observed that the response close to the pier root (left) is smoother than the response derived from the sensors located at the sea side end. In particular, the sensors located on the surface of the blocks seem to give a less significant response. 1 8 6 4 Cz [1/mm] 2-2 -4-6 -8-1 3/11/99 13.1 11/12/99 5. 23/12/99 4.59 3/1/ 4.59 14/1/ 4.58 25/1/ 4.58 5/2/ 5.1 16/2/ 5.1 27/2/ 5. 1/3/ 5. 21/3/ 5. 2/4/ 4. 13/4/ 3.59 24/4/ 3.59 5/5/ 4. 16/5/ 4. 27/5/ 3.58 S1 7/6/ 3.58 S2 S3 S4 S5 S6 S7 S8 S9 S1 S11 S12 S13 Sections C8-B1 S16 S15 S14 Figure 7: time-curvature-space plot for the entire wall. 5 Statistical correlation analysis A further step in data analysis and interpretation has been performed by applying a signal processing technique, called proper orthogonal decomposition [6]. This technique has the aim of filtering out the noise from the signal and has been used to obtain clean space-time responses in terms of strains and curvatures. In general terms, a signal can be decomposed in the sum of an average value in time and of a zero-average time fluctuation. It is then possible to compute the correlation matrix of the data, and perform an eigenvalue analysis. The time-invariant eigenvector associated to the maximum eigenvalue represents the dominant trend in space of the data, corresponding to the time function with the maximum variance. The analysis performed on strain and curvature responses has confirmed that such filtered

time history of the strains and curvatures is still correlated to the variation of the temperature in time. 6 Conclusions A first analysis and interpretation of the data collected from the long-term monitoring system of the San Giorgio pier has shown that the structural behaviour can be characterised in terms of its response to environmental temperature variations. Other informative observations will be obtained from the short-term monitoring experiments planned in the next future. During these experiments, the campaigns will concern only part of the sensors, to observe the structural response during unloading of ships and manoeuvring of the cranes. References [1] D. Inaudi S. Vurpillot, SOFO: Surveillance d Ouvrages par Fibres Optiques, IAS, 26, Switzerland, 1995. [2] D. Inaudi A. Elamari S. Vurpillot, Low-coherence interferometry for the monitoring of civil-engineering structures, Smart structures and materials conference, Glasgow, 1994. [3] D. Inaudi, Fiber optic sensor network for the monitoring of civil engineering structures, Ecole Polytechnique Fédérale de Lausanne, Thèse de doctorat N 1612, 1997. [4] A. Del Grosso D. Inaudi G. Brunetti M. Fedolino, Monitoring of the San Giorgio Pier in the Port of Genoa with Fibre Optic Displacement Sensors. Int. Conf. Monitoring and Control of Marine and Harbour Structures, Genoa, 1-4 June 1999. [5] S. Vurpillot, Analyse automatisée des systèmes de mesure de déformation pour l auscultation des structures. Ecole Polytechnique Fédérale de Lausanne, Thèse de doctorat N 1982, 1999. [6] E. Kreuzer O. Kust, Analysis of long torsional strings by proper orthogonal decomposition, Archive of Applied Mechanics, 67, pp. 68-8, 1996.