Construction Exits Vibration grids

Similar documents
Construction Exits Rock pads

Rock & Aggregate Drop Inlet Protection

Coarse Sediment Traps

[1] Performance of the sediment trap depends on the type of outlet structure and the settling pond surface area.

U-Shaped Sediment Traps

Type 1 System Sheet Flow Sandy Soils Type 2 System Concentrated Flow Clayey Soils Type 3 System [1] Supplementary Trap Dispersive Soils

Sediment Weirs (Instream)

Chutes Part 5: Rock linings

Low Gradient Velocity Control Short Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1]

Rock Sizing for Multi-Pipe & Culvert Outlets

Stormwater Inlet Sediment Traps

Specifications Whitcomb Elementary School Demolition January 15, 2016

Instream Sediment Control Systems

Stormwater Outlet Sediment Traps

Rock Sizing for Batter Chutes

Rock Sizing for Waterway & Gully Chutes

Rock Sizing for Small Dam Spillways

Materials. Use materials meeting the following.

Continuing Education Associated with Maintaining CPESC and CESSWI Certification

Sediment Trap. At multiple locations within the project site where sediment control is needed.

Stone Outlet Sediment Trap

Soil Erosion and Sediment Control. Basic Principles and Practices

Erosion and Sediment Control Measures 2.7 Silt Fences

Track design and management

Erosion and Sediment Control Field Guide for Builders. Version 3, January 2013

Rock Sizing for Drainage Channels

Orica Australia Pty Ltd Ammonium Nitrate Facility Upgrade

Suitable Applications Sediment traps should be considered for use:

CONSTRUCTION EXIT SEDIMENT BARRIER

FOR PROJECTS INITIATED AFTER NOVEMBER 1, 2008 ITEM 716 EMBANKMENT EARTH OUTLET SEDIMENT TRAP

Woodford County Erosion Prevention Plan and Permit. Application #

CITY OF NEW LONDON WINTER ROAD & SIDEWALK MAINTENANCE POLICY

CITY OF BEAVER DAM SNOW & ICE REMOVAL POLICY

Storm Sewer Design [2]

Gully Erosion Part 1 GULLY EROSION AND ITS CAUSES. Introduction. The mechanics of gully erosion

APPENDIX B WORKSHEETS & EXHIBITS

MIDDLESEX COUNTY Department of Planning and Community Development P.O. Box 427, Saluda, VA Phone: Fax:

B805 TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES - OPSS 805

1.0 INSPECTION ANNUAL INSPECTION, JUNE 29, 2011 CARMACKS COPPER PROJECT, CARMACKS, YUKON. Dear Mr. West-Sells,

Selected Site BMPs: Why s the Water Muddy? John C. Hayes, Ph.D., P. E. Biosystems Engineering Clemson University

Rock Scaling Recommendations Logan Creek Drive Cut Slope

Sediment Trap. A temporary runoff containment area, which promotes sedimentation prior to discharge of the runoff through a stabilized spillway.

Rock Sizing for Bank Stabilisation

TPDES: Soil, Erosion and Sedimentation Methods

OXFORD HEIGHTS SUBDIVISION EMERGENCY EVACUATION PLAN

APPENDIX B DESIGN CRITERIA FOR TEMPORARY WATER QUALITY BMPS USED DURING CONSTRUCTION

ISSUED FOR CONSTRUCTION

APPENDIX G APPENDIX G SEDIMENT CONTAINMENT SYSTEM DESIGN RATIONALE

CHAPTER FIVE 5.0 STABILITY OF CUT SLOPES IN THE STUDY AREA. them limited by a thick canopy of vegetation and steep slope angles.

Instream Erosion Control General

Sediment Capture in Pervious Concrete Pavement tsystems: Effects on Hydrological Performance and Suspended Solids

Erosion and Sediment Control Plan

Independent Environmental Audit Erosion and Sediment Control

John A. Carlson Snow and Ice Removal


STREUVER FIDELCO CAPPELLI, LLC YONKERS DOWNTOWN DEVELOPMENT PHASE 1. DRAFT ENVIRONMENTAL IMPACT STATEMENT For: PALISADES POINT

The results of KCB s site inspection observations and our recommendations for further work are presented herein.

Converse Consultants Geotechnical Engineering, Environmental & Groundwater Science, Inspection & Testing Services

APPENDIX A: EROSION & SEDIMENT CONTROL FORMS

CCR Rule Annual Inspection Report (cont.) 2

City of Saginaw Right of Way Division Snow and Ice Removal Policy January 18, 2016

ADDENDA #1 CONTRACT # C May 3, 2013 Page 1 of 1

In-channel coarse sediment trap Best Management Practice

TABLE OF CONTENTS LIST OF TABLES. Page

**Temporary Erosion Control**

Traffic Control Weather Policy

Erosion and Sediment Control A Field Guide for Construction Site Managers. Version 6, July 2017

Central Queensland Coal Project Appendix 4b Geotechnical Assessment. Environmental Impact Statement

RISK RATING SAFE WORK METHOD STATEMENT 1 HIGH 2 MEDIUM 3LOW. I approve the use of this Safe Work Method Statement: NAME: POSITION: Department Manager

CUMO INSPECTION REPORT #6 Page 1

PW 001 SNOW REMOVAL AND SANDING FOR ROADWAYS AND SIDEWALKS October 6, 2014 (#223-14) Original October 19, 2015; October 15, 2018 Public Works

Landslide Mitigation (BYUI)

Franklin County Engineer's Office - Highway Design Dublin Road And Fishinger Road Improvements Rebid Bid Tabulation

SOIL AND AGGREGATE FUNDAMENTALS STUDENT GUIDE AMRC April, 2006 AREA MANAGER ROADS CERTIFICATION PROGRAM FOR EDUCATIONAL PURPOSES ONLY

Use of Rock in Stormwater Engineering. Version 3, July 2017

Standards for Soil Erosion and Sediment Control in New Jersey May 2012

City of Laramie, Wyoming SNOW AND ICE POLICY

ROCK EXCAVATION (GRADING) OPSS 206 INDEX

FINAL REPORT NO.54. Erosion and Sediment Control Plan - Coastal Reclamation. Tauranga City Council. Private Bag Tauranga 16 August

How Can DOT Operations and Maintenance Prepare for Extreme Weather Events?

Snow and Ice Control POLICY NO. P-01/2015. CITY OF AIRDRIE Snow and Ice Control Policy

August 10, 2007 File:

NORTH DAKOTA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TEMPORARY EROSION AND SEDIMENT BEST MANAGEMENT PRACTICES

HISTORY OF CONSTRUCTION FOR EXISTING CCR SURFACE IMPOUNDMENT PLANT GASTON ASH POND 40 CFR (c)(1)(i) (xii)

QUICK REFERENCE FOR PRECAUTIONARY TREATMENT DECISION MAKING

5. Which surface soil type has the slowest permeability rate and is most likely to produce flooding? A) pebbles B) sand C) silt D) clay A) B) C) D)

H IG HWAY WINTER OPERATIONS SNOW REMOVAL AND ICE CONTROL POLICY. Revised January 4, 2016

WELCOME Lake Wabukayne OPEN HOUSE

Deicing (Winter Operations) on Porous and Permeable Pavements. Laura Fay October 27, 2016

CENTRAL REGION GEOHAZARDS RISK ASSESSMENT SITE INSPECTION FORM

MEDIA RELEASE FOR IMMEDIATE RELEASE March 17, 2014 Preparing for the Spring Thaw

FROST HEAVE. GROUND FREEZING and FROST HEAVE

BAD WEATHER DOESN T CAUSE ACCIDENTS

Sediment Control Practices. John Mathews Ohio Dept. of Natural Resources, Division of Soil and Water Resources

Re: Steep Slope Assessment for 2465 Waverly Drive, Blind Bay, BC; Legal Address: Lot 39, Section 18, Township 22, Range 10, Plan 25579, W6M, KDYD.

Storing, using and disposing of unsealed radioactive substances in a Type C Laboratory: Extract of regulatory requirements

Case Study 2: Twenty-mile Creek Rock Fords

Template for Sediment and Erosion Control Plan General Instructions. Section Instructions

May 22, Mr. Tim Tyler TRWME Properties, LLC 240 Hwy. 65 N Conway, AR RE: Royal Oaks Vista Subdivision Site. Dear Mr.

Sample Snow Services Proposal Alle Rorie 7157 E Kemper Rd Cincinnati, OH Phone: (800)

Transcription:

Construction Exits Vibration grids SEDIMENT CONTROL TECHNIQUE Type 1 System Sheet Flow Sandy Soils Type 2 System Concentrated Flow Clayey Soils [1] Type 3 System Supplementary Trap Dispersive Soils [1] Reduced efficiency should be expected for clayey soils, especially during wet weather. Symbol Photo 1 Vibration grid and rock pad Photo 2 Vibration grid Key Principles 1. The critical design parameter is the length of the vibration grid. 2. Vibration grids operate best during dry weather, thus the adjoining rock ramps are essential for sediment control during wet weather. 3. The sediment trapping ability of the adjoining rock ramps is directly related to the volume of open voids between the rocks, which is related to the uniformity of the rock size, and the length and depth of rock. Design Information Vibration grids are most commonly formed from metal angle (e.g. 100x100x10mm) at approximately 270mm spacing. The metal grid must not be placed directly on the ground, but elevated above a suitable sediment collection chamber (e.g. an inverted box culvert). Recommended minimum length of the vibration grid is 4m, but the overall minimum length of the stabilised construction exit (i.e. grid plus rock ramps) is 15m. Minimum width of 3m or 2.5m per lane. An adequate sediment storage collection chamber is required under the vibration grid. An access track between the vibration grid and the sealed roadway must be stabilised with rock as per the requirements for Rock Pads. The rock pad/ramp is to be made safe for foot traffic if it crosses an open footpath. Rock must placed on filter cloth (minimum bidim A24 or equivalent) if located on clayey or unstable soils. Catchments & Creeks Pty Ltd Version 2 - April 2010 Page 1

Figures 1 and 2 show the typical layout of a vibration grid within an extended rock pad. The rock pad normally needs to be formed above natural ground level to accommodate the sediment collection chamber beneath the vibration grid. Figure 1 Typical layout of vibration grid with rock ramps Figure 2 Typical layout of vibration grid with rock ramps There are many variations in the design of vibration grids as can be seen in Photos 2, 3 and 4. Figure 3 shows the typical dimensions of a vibration grid formed from metal angles. Figure 3 Typical arrangement of vibration grid and sediment collection chamber Catchments & Creeks Pty Ltd Version 2 - April 2010 Page 2

Photo 3 Vibration grid Photo 4 Vibration grid One of the regular problems associated with the use of vibration grids is the reluctance of owner-drivers to use the grids due to possible truck damage. An alternative design concept, which is in the early stages of development, is the use of a coarse rock layer on top of the grid (Figure 4) to reduce damage to trucks while maintaining the unit s full sediment trapping ability. Alternatively, heavy duty decking mesh (Figure 5) can be used. Both these systems more closely simulate the sediment trapping actions of traditional rock pads. Figure 4 Alternative conceptual design using rock upper course Figure 5 Alternative conceptual design using upper mesh layer Catchments & Creeks Pty Ltd Version 2 - April 2010 Page 3

Description Construction exit is a general term referring to rock pads, vibration grids and wash bays. Vibration grids typically consist of prefabricated metal grids (Photos 2, 3 & 4) placed on concrete sediment collection chambers. Purpose The basic aim of a vibration grid is to help prevent sediment being released onto public roads via the entry or exit road. Principally used to vibrate dry, sandy soil from vehicle tyres. Stabilised construction exits are one of the few sediment control measures that are required during both wet and dry weather. Limitations Vibration grids are supplementary sediment traps typically of low sediment trapping efficiency. Sediment trapping efficiency is generally related to the soil type and weather conditions. The vibration grid is most effective during dry weather conditions. The associated rock ramps are most effective during wet weather conditions. Generally not used on building sites. Vibration grids (in isolation from a rock pad) are not effective in removing cohesive (sticky) soil from vehicle tyres. Advantages The prefabricated units can be hired. Welded steel grids can be constructed then reused for several years. A combined vibration grid and rock pad is generally more effective than a rock pad in isolation. Disadvantages Requires regular maintenance including desilting the sediment collection chamber and adding/replacing rock. It is important to locate the construction exit such that vehicles cannot bypass the vibration grid when exiting the site. The construction site entry/exit point may not necessarily be located at the permanent site entry/exit point. Vibration grids should be set back from the public roadway to allow maximum deposition of sediment. Common Problems Inadequate maintenance. Inadequate sediment storage volume below the grid. Sediment not regularly removed from the rock ramps or collection chambers. Drainage not adequately controlled at the entry/exit point, allowing sediment-laden stormwater runoff to wash onto public roads. Special Requirements The vibration grid must be set inside either a rock pad or sealed roadway. Surface water flowing over the construction exit sediment trap must be directed to a sediment trap. The vibration grid must not become a source of sediment runoff onto the adjacent road. A square-edged shovel and large stiffbristled broom must be available on-site for maintenance. Rock must be placed on filter cloth (minimum bidim A24 or equivalent) if placed on clayey or unstable soils. Site Inspection Check for excessive sedimentation on the associated rock ramps/pad. Check for sediment tacked onto the road. Check if an additional layer of rock is required on the rock ramps. Ensure surface runoff is directed to a suitable sediment trap. Location Located at site entry points, or where vehicles pass from unsealed roads onto sealed roads. Catchments & Creeks Pty Ltd Version 2 - April 2010 Page 4

Materials Rock: well graded, hard, angular, erosion resistant rock, nominal diameter of 50mm to 75mm (small disturbances) or 100 to 150mm (large disturbances). All reasonable measures must be taken to obtain rock of near uniform size. Footpath stabilising aggregate: 25 to 50mm gravel or aggregate. Geotextile fabric: heavy-duty, needlepunched, non-woven filter cloth ( bidim A24 or equivalent). Installation 1. Refer to approved plans for location and dimensional details. If there are questions or problems with the location, dimensions, or method of installation, contact the engineer or responsible onsite officer for assistance. 2. Clear the location of the vibration grid, removing stumps, roots and other vegetation to provide a firm foundation so that the rock is not pressed into soft ground. Clear sufficient width to allow passage of large vehicles, but clear only that necessary for the exit. Do not clear adjacent areas until the required erosion and sediment control devices are in place. 3. Grade the location of the vibration grid so that runoff from the unit will not flow into the street, but will flow towards an appropriate sediment-trapping device. 4. Ensure that the installation of the vibration grid includes adequate sediment storage volume under the grid. Where necessary, install suitable precast sediment collection chambers. 5. Place a rock pad/ramp forming a minimum 200mm thick layer of clean, open-void rock over the roadway between the vibration grid and the sealed street to prevent tyres from picking up more soil after they have been cleaned. 6. The total length of the vibration grip and rock ramps should be at least 15m where practicable, and as wide as the full width of the entry or exit and at least 3m. The rock ramp should commence at the edge of the off-site sealed road or pavement. 7. Flare the end of the rock pad where it meets the pavement so that the wheels of turning vehicles do not travel over unprotected soil. 8. If the footpath is open to pedestrian movement, then cover the coarse rock with fine aggregate or gravel, or otherwise take whatever measures are needed to make the area safe Maintenance 1. Inspect vibration grid prior to forecast rain, daily during extended periods of rainfall, after significant runoffproducing rainfall, or otherwise at fortnightly intervals. 2. If sand, soil, sediment or mud is tracked or washed onto the adjacent sealed roadway, then such material must be physically removed, first using a square-edged shovel, and then a stiffbristled broom, and then by a mechanical vacuum unit, if available. 3. If necessary for safety reasons, the roadway shall only be washed clean after all reasonable efforts have been taken to shovel and sweep the material from the roadway. 4. When the voids between the rock becomes filled with material and the effectiveness of the rock ramps are reduced to a point where sediment is being tracked off the site, a new 100mm layer of rock must be added and/or the rock pad must be extended. 5. Ensure any associated drainage control measures are maintained in accordance with their desired operational condition. 6. Dispose of sediment and debris in a manner that will not create an erosion or pollution hazard. Removal 1. The vibration grid should be removed only after it is no longer needed as a sediment control device. 2. Remove materials and collected sediment and dispose of in a suitable manner that will not cause an erosion or pollution hazard. 3. Re-grade and stabilise the disturbed ground as necessary to minimise the erosion hazard. Catchments & Creeks Pty Ltd Version 2 - April 2010 Page 5