Appendix B1. Reports of SMU

Similar documents
Surface Roughness - Standards and Uncertainty R. Krüger-Sehm and L. Koenders

Guideline DKD-R 4-2. Sheet 3. Edition 7/2011.

Technical Protocol of the Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1

T.V. Vorburger, J.F. Song, T.B. Renegar, and A. Zheng January 23, 2008

TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS

Final Report On COOMET Vickers PTB/VNIIFTRI Key Comparison (COOMET.M.H- K1.b and COOMET.M.H- K1.c)

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Calibration of measuring instruments and standards for roughness measuring technique

Final report on CCQM-K36.1 with erratum

Comparison protocol EURAMET project

Metallic materials Brinell hardness test. Part 3: Calibration of reference blocks

Bilateral comparison on micro-cmm artefacts. between PTB and METAS. Final report

Commissioning of the Beta Secondary Standard (BSS2)

Supplementary Comparison EURAMET.EM-S19 EURAMET Project No. 688

ISO INTERNATIONAL STANDARD. Metallic materials Vickers hardness test Part 3: Calibration of reference blocks

< Final report > Report on the APMP.M.F-S1 supplementary comparison for 2 MN Force

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

Available online at ScienceDirect. Andrej Godina*, Bojan Acko

Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60

Physikalisch-Technische Bundesanstalt

INTERNATIONAL COMPARISON OF PLATINUM RESISTANCE THERMOMETERS BETWEEN CHILE AND ECUADOR

COMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR FORCE UP TO 1 MN AND TORQUE UP TO 2 KN M

A bilateral comparison of a 1 kg platinum standard

COOMET.M.V-S2 (587/RU-a/12) COOMET SUPPLEMENTARY COMPARISON IN THE FIELD OF MEASUREMENTS OF LIQUIDS KINEMATIC VISCOSITY

Centre for Metrology and Accreditation, MIKES

Report on EURAMET.M.M-S9

The National Unitary Institution "Belarusian State Institute of Metrology" (BelGIM)

Final Report 06 July 2006 Frank Wilkinson, Gan Xu, and Yuanjie Liu

Comparison of national air kerma standards for ISO 4037 narrow spectrum series in the range 30 kv to 300 kv

Physikalisch Technische Bundesanstalt

METHODS TO CONFIRM THE MEASUREMENT CAPABILITY OF THE FORCE STANDARD MACHINES AFTER REINSTALLATION

A laser metroscope for the calibration of setting rings

Portuguese Institute for Quality. Contents

ISO INTERNATIONAL STANDARD

RECENT ILC ACTIVITY IN ROMANIAN MASS MEASUREMENTS

Withdrawn at December 31, Guideline DKD-R 5-7. Calibration of Climatic Chambers DEUTSCHER KALIBRIERDIENST

Traceability of on-machine measurements under a wide range of working conditions

SIM Regional Comparison on. The Calibration of Internal and External Diameter Standards SIM.L-K FINAL REPORT July 2012

AFRIMETS. Supplementary Comparison Programme. Calibration of Gauge Blocks. by Mechanical Comparison Method AFRIMETS.L S3.

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

ESTIMATION OF UNCERTAINTY IN HARDNESS MEASUREMENT OF RUBBER AND OTHER ELASTOPLASTIC MATERIALS

Final Report on the Torque Key Comparison CCM.T-K2 Measurand Torque: 0 kn m, 10 kn m, 20 kn m Dirk Röske 1), Koji Ogushi 2)

Annex A Procedure for Determining the Uncertainty of Coordinate Measurement Using Multiple Method

ANNEXE 8. Technical protocols for the interlaboratory comparisons

Final Report On RMO VICKERS KEY COMPARISON COOMET M.H-K1

High pressure comparison among seven European national laboratories

University of Huddersfield Repository

EUROMET Comparison of a 10 mh Inductance Standard at 1 khz EUROMET.EM-K3. Final Report

Upgrade of 5m-Bench System for Traceable Measurements of Tapes and Rules at SASO-NMCC Dimensional Laboratory

Comparison of Results Obtained from Calibration of a Measuring Arm Performed According to the VDI/VDE, ASME and ISO Standards

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

Height Master Page 343. Check Master Page 347. Calibration Tools Page 352

CALIBRATION REPORT FOR THERMOHYDROMETER

The Fundamentals of Moisture Calibration

Ajchara Charoensook, Chaiwat Jassadajin. National Institute of Metrology Thailand. Henry Chen, Brian Ricketts and Leigh Johnson

POWER QUALITY MEASUREMENT PROCEDURE. Version 4 October Power-Quality-Oct-2009-Version-4.doc Page 1 / 12

A comparison of primary platinum-iridium kilogram mass standards among eighteen European NMIs

Spa & Wellness for Pipettes

Report on Key Comparison COOMET.AUV.A-K5: Pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 khz

Final Report EUROMET PROJECT 818 CALIBRATION FACTOR OF THERMISTOR MOUNTS. Jan P.M. de Vreede

Urban Legends in Gasmetering

EUROMET Project 702 EUROMET.M.D-K4

CVS Calibration System CVS-KAL. Short Instruction Manual. System Configuration Description of the Equipment

MASS AND VOLUME COMPARISONS AT MIKES

DETERMINATION OF FORM MEASURING MACHINE DISPLACEMENT SENSOR CHARACTERISTICS WITH A USE OF FLICK STANDARD

OIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air

ITTC Recommended Procedures and Guidelines

Euramet project 1187 Comparison of Instrument Current Transformers up to 10 ka. Technical protocol (March 2012)

TEMPERATURE COMPENSATION DURING CMM INSPECTION

ERROR LIMITS AND MEASUREMENT UNCERTAINTY IN LEGAL METROLOGY

Revision of CMM performance specifications

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

Know Your Uncertainty

Metallic materials Knoop hardness test. Part 1: Test method. Matériaux métalliques Essai de dureté Knoop Partie 1: Méthode d'essai

High pressure comparisons between seven European National Laboratories

EA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

Final Report August 2010

Calibration and verification: Two procedures having comparable objectives and results

GULF ASSOCIATION FOR METROLOGY. Calibration of Gauge Blocks by Mechanical Comparison Method GULFMET.L-S1

Introduction to the evaluation of uncertainty

Guidelines on the Calibration of Static Torque Measuring Devices

Loadcell Calibration - Evaluation of Uncertainties

INVESTIGATION OF TRANSFER STANDARDS IN THE HIGHEST RANGE UP TO 50 MN WITHIN EMRP PROJECT SIB 63 Falk Tegtmeier 1, Michael Wagner 2, Rolf Kumme 3

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

MOY/SCMI/36 SPECIFICATION OF ACCURACY FOR A PRECISION CLINOMETER

Report on APMP Supplementary Comparison High precision roundness measurement APMP.L-S4. Final report

Spa & Wellness for Pipettes

Metrological Characterization of a Primary Vickers Hardness Standard Machine - NIS Egypt

Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR

Comparison Euramet 898

Measuring Instruments Directive (MID) MID/EN14154 Short Overview

Open Access Repository eprint

Introduction To Metrology

Force Key Comparison EUROMET.M.F-K2. (50 kn and 100 kn) EURAMET Project No 518. Final Report. 14 July Pilot: NPL, United Kingdom

Air velocity & IAQ measuring instruments

CCM Vickers key comparison. Final Report

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

THE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY

Transcription:

Appendix B1 Reports of SMU

Euromet Project 600 Comparison of Surface Roughness Standards /13 EUROMET SUPPLEMENTARY COMPARISON SURFACE TEXTURE Project No. 600 Final Report Elaborated by: M. Szmicskova Bratislava, December 00

Euromet Project 600 Comparison of Surface Roughness Standards 3/13 CONTENT: 1. INTRODUCTION 3. STANDARDS 3 3. REPORT 4 3.1 INTRODUCTION OF THE ORGANISATION 4 3. DESCRIPTION OF THE MEASUREMENT EQUIPMENT 5 3.3 MEASUREMENTS 6 3.4 MEASUREMENT RESULTS, COMBINED STANDARD UNCERTAINTY 7 3.5 UNCERTAINTY CALCULATION AND DEGREES OF FREEDOM 7 3.6 REFERENCES 9 PAGE Annex: Measurement results

Euromet Project 600 Comparison of Surface Roughness Standards 4/13 1 INTRODUCTION Surface texture has a crucial influence onto the functional properties of devices and their individual parts. This quantity is of technical consequences, it has influence on the value of friction coefficient when two surfaces are in contact. Relief of the surface is a spacial formation, which we can measure and evaluate. In the case of SMU we are applying profile method using the contact profilometer. Comparison measurements at the different levels of metrological assurance are being conducted in order to check a reliability and comparability of the measurement results. This project was proposed at the EUROMET length contact persons meeting (Prague, 1999). The need of such comparison arose from the fact that the last international comparison in this field was completed in 1989 and the instrumental equipment, standards and software filtration have been improved since then. The pilot laboratories of this supplementary comparison are PTB Braunschweig and Center for Geometrical Metrology, Technical University of Denmark, Lyngby. STANDARDS In the frame of supplementary comparison (EUROMET #600 - pilot laboratories Physikalisch-Technische Bundesanstalt, Braunschweig, Germany, Center for Geometrical Metrology, Technical University of Denmark, Lyngby) the surface texture standards types C, D and A were delivered to the SMU. They were packed in the special box, containing the following items: 1. Instructions in short version discs: a. Final.ZIP b. Test smd.zip. Copy of the Technical protocol 3. Data sheet with addresses of the participants 4. Photographs of standards in their initial state 5. 8 pieces of standards: 1 piece depth setting standard of type A 3 pieces roughness standards of type C3 3 pieces roughness standards of type D1 1 piece roughness standard of type D The standards were delivered from IPG Portugal. Prior to the measurement itself, the standards were inspected for the damage and compared to the photographs documenting their initial state before the circulation. Inspection was performed by the optical microscope in a clean environment. All damages (scratches, dots and dirt) were recorded. The coordinator was informed by fax and E-mail. The following damages has been recorded: surface texture standards were damaged only in those parts visible on photograps made at PTB, with the exception of standard No 1.006, which was damaged significantly -; grooves on the metal part could be observed by eye..

Euromet Project 600 Comparison of Surface Roughness Standards 5/13 3 Report On the basis of instructions stated in Technical protocol Euromet Project 600 the laboratory of surface roughness SMU submits the report on measurement results to the pilot laboratory. The report contains the following parts: 3.1 Introduction of the organisation 3. Description of the measurement equipment 3.3 Measurement itself 3.4 Measurement results, combined standard uncertainty 3.5 Uncertainty calculation and degrees of freedom 3.6 References 3.1 INTRODUCTION OF THE ORGANISATION Slovak Institute of Metrology (SMU) as the national metrological institution is the contributory subject founded by the Office for standardisation, metrology and testing of the Slovak Republic (UNMS SR). Statutary organ of the institute is the director, in the case of his absence represented by the deputy director general. Competence corresponding to the individual functions follow the Organisation order, Working order, internal documents, Instructions of directors of centres and the generally valid legal documents.. Activities of the SMU are related to the solution of research problems, development, improvement and maintanace of the national standards and harmonization of their quality with standards of other national metrological institutes. Besides SMU provides metrological services on the highest required level, performs research tasks and elaborates norms. SMU has received the Certificate of Quality Management System according to ISO 9001:000 in October 11 th, 00 from the company LGA InterCert.

Euromet Project 600 Comparison of Surface Roughness Standards 6/13 3. DESCRIPTION OF THE MEASUREMENT EQUIPMENT In the laboratory of surface roughness SMU, the contact profilometer TALYSURF 6 is being used for the measurement. A data transfer from the working standards to the standards of lower orders is realized by the method of direct comparison, where the calibrated and reference standards are of the same nominal values. In the laboratory are calibrated measures and standards, while internal working procedures and corresponding national technical norms in the field of surface roughness are used. SMU owns the following standards : a/ type A divided into types A 1 and A : groove depth is measured in the range (0,03 10)µm with u c = (1-3)% b/ type C divided into types C 1, C, C 3, C 4 : parameter Ra is measured in the range c/ type D : (0,1 6)µm with u c = (3-6)% parameters Rz, Ry (Rmax)... are measured in the range (0,1 10)µm with u c = (3-10)% Contact profilometer TALYSURF 6, type S 11/160 is used in the laboratory of surface roughness for the measurement of geometrical structure of surface by the contact profile method and transformation of the information about profile during the mechanical movement of the tip on the calibrated surface. Mechanical signal generated by the stylus (sensor No 1/160-1690 with reference plane and tip radius of,0 µm) follows the relief of the measured surface. The stylus is mounted onto arm, which can rotate around the plug of the sensing system. This makes possible for the stylus to follow the profile. Mechanical signal from the mechanical part of the contact profilometer is transformed to the electrical one and then digitalized, or the output is a graphical record of the profile. The value of force on the tip is 1 mn.

Euromet Project 600 Comparison of Surface Roughness Standards 7/13 Data evaluation is being performed by the computer and programme TalyProfile 3.0.8. This programme enables the wide choice of parameters, setting of cut off, digitalization of the signal and the grafical record. Measured values of the parameters d m, Ra, Rz, Ry etc. are the resultant values stated from x measurement points equidistantly situated in the working aria of the calibrated standard and the expanded uncertainty of calibration U (k = ) is valid for the whole working area. Uncertainties were estimated according TPM 0051-03 being in accordance with international standard for the unceratinty evaluation (GUM). The true value lies in the interval with probability of 95%. The measurement system is situated on the antivibrating support. 3.3 MEASUREMENT Preparation of the measurements: ƒ external inspection and checking for the labelling firstly we observed the overall appearence of standards for their mechanical damage, traces of rust, scratches ƒ checking of the dimensions, whether they comply with those given in Technical protocol ƒ preparation of the contact profilometer for the measurement, situating the standard on the table with possibility of fine displacement, choice of measuring paths ƒ výber rýchlosti 1 mm/s ƒ choice of magnification 5000x and 10000x ƒ stylus of the profilometer 1 ƒ standard of the profilometer 65 µm The temperature of contact profilometer Talysurf 6 has to be stabilized at least one our before the measurement itself. Profilometer is adjusted according to the manual. The standard being in the accessories to the profilometer is used for the adjustment. Measurement procedure: The reference standard and the standard to be calibrated are subsequently located on the profilometer cross table and their profiles in the chosen areas are read according to the technical protocol (area of measurement) of the individual standards. The standard is placed on the table by such a way that a motion of the instrument sensor is in the direction of the highest values of vertical parameters. In these sections both R i and d i are measured, separately for each roughness characteristic. From the measured values the mean value and its standard deviation s is calculated. In each section of calibrated standard, three repeated measurements were carried out with corresponding determination of the given parameter. The reference standard was calibrated before the measurement and after completion of measurement (checking of the profilometer, whether it keeps its parameters). Data evaluation is by computer and programme TalyProfile 3.0.8.

Euromet Project 600 Comparison of Surface Roughness Standards 8/13 Evaluation of the measured values of parameters d, Ra, Rz, Rmax, Rk, Rpk, Rvk was done by the direct comparison, when both reference and calibrated standards had the same nominal values. The values of spatial parameters Pt, RSm and parameters reflecting the material characteritics Mr1, Mr are approximate. Filtration of measured values of parameters d, Ra, Rz and Rmax was performed by the choice of Gaussian filter, Rk parameter was filtrated by the double Gaussian filtre. Measurement conditions: ƒ ambient temperature was during measurements conditioned to (0 ± 1) C, ƒ relative humidity during measurements didn t exceed 65 %, ƒ outside the measuring period the relative humidity in the air-conditioned laboratory didn t exceed 70 % 3.4 MEASUREMENT RESULTS, COMBINED STANDARD UNCERTAINTY Table of measured values and uncertainties Annex No. 1 3.5 UNCERTAINTY CALCULATION AND DEGREES OF FREEDOM Measurement uncertainty is evaluated according to TPM 0051-93. In the following table the uncertainty budget containing all components taken into account is given. Reference standard: serial number 038641/93 nominal value 0,3 µm value given in the calibration certificate d E = 0,74 µm uncertainty given in the cal. certificate 0,00 µm Measured values: 1 3 a 0,58 µm 0,55 µm 0,66 µm b 0,58 µm 0,6 µm 0,67 µm c 0,63 µm 0,59 µm 0,65 µm D E = 0,61 µm u BE = 0,00139 µm

Euromet Project 600 Comparison of Surface Roughness Standards 9/13 Calibrated standard: serial number 0391806/65 nominal value 0, µm type EN 806 Measured values: 1 3 a 0,43 µm 0,47 µm 0,4 µm b 0,47 µm 0,49 µm 0,4 µm c 0,51 µm 0,49 µm 0,49 µm d 0,51 µm 0,5 µm 0,5 µm e 0,44 µm 0,49 µm 0,43 µm D = 0,47 µm u A = 0,000864 µm d = d E. D = 0,74. DE 0,4706 0,61 = 0,59167 0,59 µm UNCERTAINTY BUDGET Quantity X i Estimate x i Standard uncertainty u(x i ) Probability distribution Sensitivity coefficient Uncertainty contribution u i (h) (nm) d 0, µm 0,86 nm normal 1 0,86 14 d E 0,74 µm nm normal 1 8 D E 0,3 µm 1,4 nm normal 1 1,4 8 Z ref 0 nm nm normal 1 19 F 1 mn 0,05 mn rectangular 8 nm/mn 1,4 9 Z tip 0 nm 3 nm rectangular 1 3 9 Degrees of freedom ν i ν eff = ( n + 1 )[ 1 + u BX / u AX ] = (67 + 1)[ 1 + 4,57 / 0,86 ] - = = 68( 1 + 8,38) = 58 19 u C = A BE BAE BZref BF BTip u + u + u + u + u + u = = 0,86 + +,0 + 1,4 +,0 + 1,4 3,0 = 4,65 nm U = k. u C =. 4,65 = 9,3 nm

Euromet Project 600 Comparison of Surface Roughness Standards 10/13 Notes: D arithmetic mean of the profile height of measured standard from n measurements D E profile height of the reference standard (comparative) d real profile height of the measured standard d E real profile height of the reference standard (comparative) Z ref the slideway profile F force of the tip to the surface Z Tip deviation of the tip from sphericity u A standard deviation of the arithmetic mean taken from the repeated measurements of the calibrated standard u BE standard uncertainty of the surface roughness parameter determination corresponding to the reference standard (comparative) given in the calibration certificate u AE - standard deviation of the arithmetic mean taken from the repeated measurements of the reference standard u BZref uncertainty from the deviation from straightness of the slideway profile u BF uncertainty from the stylus force u BTip uncertainty from the deviation from sphericity of the tip

Euromet Project 600 Comparison of Surface Roughness Standards 11/13 3.6 References Related background documents, working procedures and metrological instructions on the basis of which the measurements were carried out: Document Title (all documents given bellow are in Slovak language) ISO 487-1 Surface roughness. Terminology. Surface and its parameters. ISO 487- Surface roughness. Terminology. Measurements of the surface texture parameters. ISO 5436 Calibration patterns. Contact instruments, types, calibration and used patterns. ISO 1156 Geometrical product specification (GPS). Character of the surface: Profile method -Metrological characteristics of the phase corrected filters. ISO 1085 Geometrical product specification (GPS). Character of the surface: Profile method Motive parameters. ISO 13565-1 Geometrical product specification (GPS). Character of the surface: Profile method - Surfaces, the functional properties of which are related to the level. Part 1: Filtration and general measurement conditions. ISO 13565- Geometrical product specification (GPS). Character of the surface: Profile method - Surfaces, the functional properties of which are related to the level. Part 1: Height characteristics by the linear par of the curve of material ratio. TPM 7030-96 Surface roughness standards of type A. Technical requirements. TPM 7031-96 Surface roughness standards of type A. Method of testing. TPM 703-97 Surface roughness standards of types C, D. Technical requirements. TPM 7033-97 Surface roughness standards of types C, D. Method of testing. TPM 0059-93 Estimation of calibration uncertainty, Parts 1 and. PP 07/10/00 Working procedure for the calibration of surface roughness patterns of types C and D. PP 08/10/00 Working procedure for the calibration of contact profilometer. PP 09/10/00 Working procedure for the calibration of vertical magnification, type A. Laboratory of surface roughness Bratislava, 0. 1. 00 Ing. Pavol Doršic Maria Szmicskova Director of the Centra of length and time performed the calibration

Euromet Project 600 Comparison of Surface Roughness Standards 1/13 Comments to the Draft 1 Euromet #600 1. Contact profilometer Talysurf 6 works with the programme TalyProfile 3.0.8, which was purchased in 00 from the company Taylor-Hobson. Programme has it own parameters fixed, which can not be changed, since such a change might effect some other parameters (filtration). Our facility operates at the fixed value of speed 1 mm/s and this fact causes very quick sampling of surface points. In the case of parameters d groove depth and standards of type D random profile these have different parameters from the reference value.. Values of parameters Pt; RSm; Mr1 and Mr were measured by the instrument and their value has been influenced by the large speed of stylus 3. Error sources resulting from the fixed parameters of the measuring programme were not taken into account and our claimed uncertainties were underestimated. In the following example are given parameters and results of calibration of the D type standard. Owner of the standard: PTB Braunsweig type : D manufacturer: PTB 99/49 serial number: 686 sg nominal values : Ra =.5 µm; Rz = 14 µm Conditions of measurement: temperature: 0.3 C speed: 1 mm/s magnification: 5000 x points: 1500 stylus tip radius µm λc = 500 µm; λs = 8 µm length: 1,5 mm

Euromet Project 600 Comparison of Surface Roughness Standards 13/13