A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

Similar documents
Engineering Physics, Tsinghua University, Beijing , China

Monte-Carlo Simulation of Response Functions for Natural Gamma-Rays in LaBr 3 Detector System with Complex Borehole Configurations

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

Efficiency. Calculations for Selected Scintillators. > Detector Counting. Efficiency. > Photopeak Efficiency of Various Scintillation Materials

Timing and Energy Response of Six Prototype Scintillators

Timing resolution measurement of a 3 Lanthanum Bromide detector

The SpecMAT project: An array of gamma-ray detectors around an active gas target

Detection and measurement of gamma-radiation by gammaspectroscopy

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

Mass of the electron m 0

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

Quality Assurance. Purity control. Polycrystalline Ingots

LANTHANUM BROMIDE SCINTILLATION DETECTOR FOR GAMMA SPECTROMETRY APPLIED IN INTERNAL RADIOACTIVE CONTAMINATION MEASUREMENTS

MCNP analysis and optimization of a double crystal phoswich detector

X ray Imaging Android [XIA]

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Characterization of the Lanthanum Chloride Scintillation Detector

Response Function of the BGO and NaI(Tl) Detectors Using Monte Carlo Simulations

PoS(INTEGRAL 2010)107

Comparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

New Scintillators for the Border Monitoring Equipment

Evaluation of the Nonlinear Response Function and Efficiency of a Scintillation Detector Using Monte Carlo and Analytical Methods

1 of :32

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

Characterization and Monte Carlo simulations for a CLYC detector

CapeSym, Inc. Radiation Detection Solutions

Design of a Lanthanum Bromide Detector for TOF PET

GAMMA RAY SPECTROSCOPY

PERFORMANCE IMPROVEMENT OF CZT DETECTORS BY LINE ELECTRODE GEOMETRY

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

arxiv: v2 [physics.ins-det] 8 Feb 2013

THALES Project No. 65/1205

Response function and linearity for high energy γ-rays in large volume LaBr3:Ce detectors

arxiv:physics/ v1 3 Aug 2006

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

Sample Spectroscopy System Hardware

Scintillation Products Technical Note

Study well-shaped germanium detectors for lowbackground

Measurement and simulation of proton induced activation of LaBr 3 :Ce

Scintillation Detector

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum

C.V. Nguyen, A.P.J. van Deursen

Large area scintillation detector for dosimetric stand with improved light collection

Deliverable D10.1. WP10 JRA04 Innovative solutions for nuclear physics detectors

Characterizing, Simulating, and Eliminating Vibration Induced Counts in Measurement While Drilling Gamma Ray Detectors. authors

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Simulation of 4π HPGe Compton-Suppression spectrometer

Preparatory experiments for cold-neutron induced fission studies at IKI

1420 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 57, NO. 3, JUNE /$ IEEE

WM2018 Conference, March 18-22, 2018, Phoenix, Arizona, USA. PVT and LaBr3(Ce)-based Radon Express Analyzers 18164

High-efficiency and fast-timing scintillators

Gamma-Spectrum Generator

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

XMASS 1.5, the next step of the XMASS experiment

New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist

Ultra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals

OPPORTUNITY TO JOIN IEEE AND NPSS

A new scintillator detector for nuclear physics experiments: the CLYC scintillator

Developing DRF for 1 X1 LaBr 3 Detector. Sangkyu Lee

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data

Direct WIMP Detection in Double-Phase Xenon TPCs

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Design and production of Scintillation Detectors

Calibration of A Small Anode Germanium Well Detector

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

The NEXT-100 experiment for Neutrino-less Double Beta decay: Main features, Results from Prototypes and Radiopurity issues.

Development of a 3D-Imaging Calorimeter in LaBr 3 for Gamma-Ray Space Astronomy

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

SCINTILLATION DETECTORS AND PM TUBES

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

The Scintillation properties of Pr 3+ doped and Pr 3+, Ce 3+

Improved scintillation proportionality and energy resolution of LaBr 3 :Ce at 80K

Measurement of high energy gamma rays with large volume LaBr 3 :Ce scintillators

2010 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Compton Camera. Compton Camera

Science of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University

PoS(TIPP2014)073. Development of a High Detection Efficiency and Low-Cost Imaging Gamma-Ray Camera γi. M. Kagaya

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Measurement of activity of the predominant gamma-emitting radionuclides in activated components of a medical cyclotron plant

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

NUCL 3000/5030 Laboratory 2 Fall 2013

The Best Gamma-Ray Detector

Development of a Hard X-Ray Polarimeter for Solar Flares and Gamma-Ray Bursts

arxiv: v1 [physics.ins-det] 3 Feb 2011

Preparation of Standard Source as a Petri Dish for Plant by Using

Transcription:

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring 1 Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education Department of Engineering Physics, Tsinghua University, Beijing, 100084, China E-mail: zengming@tsinghua.edu.cn Zhi Zeng, Jirong Cang, Xingyu Pan, Tao Xue, Hao Ma, Hongchang Yi, Jianping Cheng Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education Department of Engineering Physics, Tsinghua University, Beijing, 100084, China E-mail: zengzhi@tsinghua.edu.cn A prototype of LaBr3:Ce in situ gamma-ray spectrometer for marine environmental monitoring is developed and applied for in situ measurement. A 3-inch LaBr3:Ce scintillator is used in the detector, and a digital pulse process electronics is chosen as the pulse height analyzer. For this prototype, the energy response of the spectrometer is linear and the energy resolution of 662keV is 2.6% (much better than NaI). With the measurement of the prototype in a water tank filled with 137Cs, the detect efficiency for 137Cs is (0.288±0.01)cps/(Bq/L), which is close to the result of Monte Carlo simulation, 0.283cps/(Bq/L). With this measurement, the MDAC for 137Cs in one hour has been calculated to 0.78Bq/L, better than that of NaI(Tl) in-situ gamma spectrometer, which is ~1.0Bq/L. Technology and Instrumentation in Particle Physics 2014 2-6 June, 2014 Amsterdam, the Netherlands 1 Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it

1.Introduction NaI(Tl) detector is the main choice in marine environmental monitoring because of its high detection efficiency stable performance low price. However the energy resolution of NaI(Tl) detector is not very high, which limits its performance. LaBr 3:Ce crystal has a series of advantages including high scintillation efficiency high energy resolution, which makes LaBr 3:Ce a potential good choice despite the self-activity in LaBr 3:Ce crystal. The main radionuclides in LaBr3 crystal are 138 La and progenies of 227 Ac. 138 La is a radioisotope of lanthanum and 227 Ac exists as a radioactive contamination in LaBr 3 crystal, which is a radionuclide in the natural 235 U decay chain. The preliminary test result of this prototype is introduced in details. 2.Framework This prototype mainly consists of underwater and aquatic two parts (See Fig. 1). Underwater system,which is responsible for the collecting of spectra, is made up of a Saint Gobain 3 3 BrilLance-380 Detector, R10233-100 photomultiplier tube (PMT), Hamamatsu CC228 high voltage supplier,amptek DP5 multichannel analyzer (MCA) etc. Aquatic system is responsible for the power management, using the solar power, and data communication. Fig. 1 System Framework Hardware system and the prototype is shown as Fig.2. Fig. 2 Hardware Framework and Prototype 2

3. Energy resolution A set of calibrated radioactive sources were used to characterize the response of the detector at various gamma-ray energies. The complete list of sources used together with their energies are reported in Table 1. Table 1. Nuclide list used in the calibration measurement Nuclide Energy/keV Nuclide Energy/keV Cs-137 661.66 867.38 Co-60 Eu-152 1173.23 Eu-152 1528.1 1332.49 276.40 344.28 302.85 411.12 356.01 443.97 133Ba 383.85 778.90 Single-energy photo peaks, without lying the Compton edgy, are chosen. According to the same analysis, we have evaluated the FWHM versus energy. Fig. 3 Energy resolution versus energy The data are best-fitted by power laws as: The exponent of ~0.5 indicates that the noise contributed by electronics is small. According to last equation, the energy resolution is 2.6% @662keV. 3

4.Intrinsic background One main reason that LaBr3:Ce detector isn t used in low background measurement widely is the intrinsic background of LaBr3. The main radionuclides in LaBr3 crystal are 138 La and progenies of 227 Ac. 138 La is a radioisotope of lanthanum and 227 Ac exists as a radioactive contamination in LaBr3 crystal, which is a radionuclide in the natural 235 U decay chain. To investigate the intrinsic activity of LaBr3 detector, the background spectrum (shown in Fig.4) of the LaBr3:Ce in-situ gamma-ray spectrometer was measured in lead shield. From the spectrum, we can distinguish several energy peaks including the 35. 5keV X ray 255 kev β continuous spectrum the combination of 789 kev γ ray and 255 kev β continuous spectrum the 1436 kev γ ray the combination of 1436 kev γ ray and 35.5 kev X ray, which come from the radioactive decay of 138 La in LaBr3 crystal. Besides, continuous spectrum from 1600 kev to 3000 kev result from the α decay of progenies from 227 Ac. The total counting rate of the background is about 1.08cps/cm 3 for the 3 3 LaBr3 detector. And, the counting rate of the α contamination occurring in the energy region from 1600keV to 3000keV is about 0.09cps/cm 3. 5.Detection efficiency Fig. 4 Intrinsic background for 3 3 LaBr3 We define detection efficiency Iγ εsp V, which is a sufficient parameter for the prototype, as the photo peak count rate when the activity concentration of 137 Cs is 1Bq/L, where Iγ is the absolute intensity of photons, εsp is ratio between photons number and counts recorded in the full energy peak, V is the volume of the area containing particle source. We both simulated and measured the detection efficiency of the prototype in a seawater tank. The seawater tank is Φ2m 2.3m containing 0.48Bq/L 137 Cs radioactive source. The simulation was done with Geant4. And the geometrical model of seawater tank and the detector is shown in Fig.5. Considering the influence of distance between particle source and LaBr3 crystal, we simulated the detection efficiency of the prototype 4

to 137 Cs in seawater sphere with different radiuses. The relationship between radius and detection efficiency indicates that the detection efficiency of this prototype is about 0.283cps/(Bq/L) when the area of seawater is large enough, which means the sphere is about 80cm. 0.30 0.25 y(cps/(bq/l)) 0.20 0.15 0.10 0.05 0 10 20 30 40 50 60 70 80 90 R(cm) Fig. 5 Model and result of the detection efficiency simulation A spectrum was measureed acturally in the seawater tank, the photo-peak analysis is depicted for 137 Cs (at 662keV) using second order polynomial fitting for the background and Gaussian fitting for the photo-peak area, as illustrated in Fig.6. Fig. 6 In-situ spectrum for 7 days acquisition time The detection efficiency calculated by experiment is (0.288±0.010) cps/(bq/l), which is in good accordance with the MC simulation. 6.Minimum detectable activity concentration A question occurs when measuring low activity materials that how to determine whether some kind of radionuclides are included. To solve the question, a physical quantity named MDAC is defined to describe the minimum detectable activity concentration of radionuclides for certain time. The MDAC of 137 Cs in seawater tank was worked out as the following: 5

According to the result of detection efficiency calculated by experiment, Iγ εsp V is (0.288±0.010) cps/(bq/l). Then, the MDAC results of the prototype to 662keV photon from 137 Cs are: 0.78Bq/L for 1 hour, 0.16Bq/L for 24 hours. 7.Conclusion Conventional NaI(Tl) in-situ gamma-ray spectrometer for marine environmental monitoring generally had its MDAC about 1.0Bq/L. And in this paper, a prototype of LaBr3:Ce in-situ gamma-ray spectrometer for marine environmental monitoring has been developed and applied for marine measurement. Because of its higher energy resolution than traditional NaI(Tl), a better MDAC of 0.78Bq/L is achieved. And the detect efficiency is (0.288±0.01)cps/(Bq/L), in good accordance with the Monte Carlo simulation. The results showed that LaBr3:Ce would be a promising choice for the in-situ marine environmental monitoring, with better MDAC and nuclide identification. Meanwhile, the prototype is still in a preliminary stage, there are several aspects to be improved. The long-term stability is to be tested, and intrinsic background of the LaBr3:Ce material is also to be studied and discriminated in the future. Acknowledgements This work is supported by the Ministry of Science and Technology special foundation work (2012FY130200), Tsinghua University, independent research project (2011080965), the National 863 Program (2012AA050907). References [1] K. S. Shah, J. Glodo, et al. LaBr3:Ce Scintillators for Gamma-ray Spectroscopy, IEEE Trans. Nucl. Sci., 2003, 50(6):2410-2413. [2] B. D. Milbrath, B. J. Choate, et al. Comparison of LaBr3:Ce and NaI(Tl) Scintillators for Radioisotope Identification Devices, Pacific Northwest National Laboratory Report PNNL-15831, 2006. [3] F. Quarati, A.J. J. Bos, S. Brandenburg, et al. X-ray and gamma-ray response of a 2 2 LaBr3:Ce scintillation detector, NIM A, 2007, 574:115-120. [4] Genghua Su, Zhi Zeng, et al. Monte Carlo Simulation of in situ LaBr gamma-ray spectrometer for marine environmental monitoring, Rad. Prot. Dosi., 2011, 146(1-3): 103-106 6