LAB 10: OPTICAL MATERIALS AND DISPERSION I

Similar documents
Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

Laboratory #29: Spectrometer

DISPERSION OF A GLASS PRISM

n(λ) = c/v(λ). Figure 1: Dispersion curves for some common optical glass types.

The Quantum Model of the Hydrogen Atom

THE DIFFRACTION GRATING SPECTROMETER

EXPERIMENT 5:Determination of the refractive index (µ) of the material of a prism using sprectometer

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

Any first year text, sections on atomic structure, spectral lines and spectrometers

Dispersion of light by a prism

Experiment #4: Optical Spectrometer and the Prism Deviation

Dispersion and resolving power of the prism and grating spectroscope (Item No.: P )

Experiment #5: Cauchy s Formula

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

Speed of Light in Glass

Atomic emission spectra experiment

Pre-lab Quiz/PHYS 224. Your name Lab section

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

The Grating Spectrometer and Atomic Spectra

Tutorials. 1. Autocollimator. Angle Dekkor. General

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 14. The Atomic Spectrum of Hydrogen

EXPERIMENT 12 THE GRATING SPECTROMETER AND ATOMIC SPECTRA

The Grating Spectrometer and Atomic Spectra

UNIT-5 EM WAVES UNIT-6 RAY OPTICS

Determination of Cauchy s Contants

Assignment 3 Due September 27, 2010

Instruction Manual and Experiment Guide for the PASCO scientific Model SP E 2/96 STUDENT SPECTROMETER. Copyright January 1991 $7.

L-7 SPECTROMETER. (3) To plot a dispersion curve for the glass prism, and use the curve for the identification of unknown wavelengths.

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

Chapter 4. Dispersion of Glass. 4.1 Introduction. 4.2 Apparatus

Lab report 30 EXPERIMENT 4. REFRACTION OF LIGHT

Protokoll. Grundpraktikum II - Optical Spectroscopy

10. Wavelength measurement using prism spectroscopy

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

To determine the wavelengths of light emitted by a mercury vapour lamp by using a diffraction grating.

Diffraction of light by a grating

The Emission Spectra of Light

DISPERSION AND SPECTRA CHAPTER 20

EXPERIMENT 14. The Atomic Spectrum of Hydrogen

Einstein Classes, Unit No. 102, 103, Vardhman Ring Road Plaza, Vikas Puri Extn., Outer Ring Road New Delhi , Ph. : ,

Atomic Spectra HISTORY AND THEORY

Dispersion of Glass Introduction Apparatus Theory

AS 101: Day Lab #2 Summer Spectroscopy

Geometric Optics. Scott Freese. Physics 262

OPTICAL INSTRUMENTS VERY SHORT ANSWER QUESTIONS

Visible Spectrometer

EXPERIMENT 12 THE WAVELENGTH OF LIGHT; THE DIFFRACTION GRATING

GEOMETRICAL OPTICS Practical 1. Part II. OPTICAL SYSTEMS

Visible Spectrometer

Rydberg constant from atomic spectra of gases

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

Lecture 2: Basic Astronomical Optics. Prisms, Lenses, and Mirrors

University of Massachusetts, Amherst

DAY LABORATORY EXERCISE: SPECTROSCOPY

PC1144 Physics IV. Atomic Spectra

INTERFEROMETERS. There are 4 principal types of measurements that can be made with this type of interferometer.

Conceptual Physics. Luis A. Anchordoqui. Department of Physics and Astronomy Lehman College, City University of New York. Lesson VI October 3, 2017

Note: Common units for visible light wavelengths are the Angstrom (Å) and the nanometer (nm).

Experiment 12: SPECTROSCOPY: EMISSION & ABSORPTION

Physics 23 Fall 1998 Lab 4 - The Hydrogen Spectrum

Physics 1252 Section Exam #1D

Physics 1252 Section Exam #1E

Optical Bench. Polarization and Brewster s Angle

Spectrum of Hydrogen. Physics 227 Lab

Physics 24, Spring 2007 Lab 2 - Complex Spectra

DISPERSION VERY SHORT ANSWER QUESTIONS. Two identical prisms made of the same material placed with their based on opposite sides (of the

IO.5 Elliptically Polarized Light

APAS Laboratory { PAGE } Spectroscopy SPECTROSCOPY

Physics 1212 Exam #1

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student

Physics I : Oscillations and Waves Prof. S. Bharadwaj Department of Physics and Meteorology Indian Institute of Technology, Kharagpur

Engineering Physics 1 Prof. G.D. Vermaa Department of Physics Indian Institute of Technology-Roorkee

LAB 12 ATOMIC SPECTRA

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

Astronomy 203 practice final examination

Science Lab I Properties of Light

ARC SPECTRUM OF IRON /COPPER / BRASS

Dispersion and how to control it

XXXXXXXXXXXXXXX. First Pre-Board Examination, Physics

PLI Support Guide: Robotic Total Station Field Calibration

Atomic and nuclear physics

Emission Spectrum of Atomic Gases. Prelab Questions

Atomic Spectra 1. Name Date Partners ATOMIC SPECTRA

Physics 1252 Sec.A Exam #1A

AP Waves/Optics ~ Learning Guide

1 cm b. 4.4 mm c. 2.2 cm d. 4.4 cm v

EXPERIMENT NO. 6. OBJECT: To determine the wavelength of any three lines of mercury light by diffraction grating in1 st and 2 nd order spectrum.

PHYS 1112 In-Class Exam #1, Version D

Complete all the identification fields below or 10% of the lab value will be deduced from your final mark for this lab.

OPTICAL SPECTROSCOPY AND THE ZEEMAN EFFECT Beyond the First Year workshop Philadelphia, July Greg Elliott, University of Puget Sound

Modern Physics Laboratory MP2 Blackbody Radiation

Instruments and Related Topics

NASA GSFC s CHARMS Facility

Illuminated Reticle Technologies for Rifle Scopes. Illuminated Reticle Technologies for Riflescopes

HYDROGEN SPECTRUM. Figure 1 shows the energy level scheme for the hydrogen atom as calculated from equation. Figure 1 Figure 2

Seat Number. Print and sign your name, and write your Student ID Number and seat number legibly in the spaces above.

Lecture 4: Diffraction & Spectroscopy

DIFFRACTION GRATING. OBJECTIVE: To use the diffraction grating in the formation of spectra and in the measurement of wavelengths.

Using the Spectrometer

Transcription:

OPTI 202L - Geometrical and Instrumental Optics Lab LAB 10: OPTICAL MATERIALS AND DISPERSION I 10-1 Measuring the refractive index of a material is one of the most fundamental optical measurements, and one of the most practical. In this lab you will use two methods for determining index. One of these, the Abbe refractometer, is a technique routinely used in modern chemistry labs for identifying chemical compounds. Experiment: Dispersion The refractive index of a glass is a function of the wavelength of light, a property known as dispersion. A plot of refractive index vs. wavelength is called a dispersion curve. Different glasses exhibit different dispersion curves, as shown below. In this experiment, you will measure the dispersion curve of a dense flint optical glass. The technique used will be the minimum angle of deviation. 2 1.9 Index of Refraction 1.8 Refraction 1.7 1.6 Dense Flint glass 1.5 1.4 Light Flint glass (LF7) Borosilicate Crown glass Fused 300 400 500 600 700 800 900 1000 Wavelength nm Figure 10.1. Refractive index vs. wavelength for various glasses.

OPTI 202L - GEOMETRICAL AND INSTRUMENTAL OPTICS LAB 10-2 Figure 10.2. Photo of the PASCO student spectrometer. (Photo printed with written permission from PASCO Scientific)

OPTI 202L - GEOMETRICAL AND INSTRUMENTAL OPTICS LAB 10-3 Extended Source (top view of slit) W f Figure 10.3. Rays from any object point emerge parallel to each other, but not parallel to rays from other object points. Red Blue Green Figure 10.4. Refraction of collimated beams through a prism.

OPTI 202L - GEOMETRICAL AND INSTRUMENTAL OPTICS LAB The Spectrometer and its Adjustment: 10-4 We wish to measure the angular deviation produced by a prism. The spectrometer is one convenient way to do this. The spectrometer consists of a slit, collimator, viewing telescope, arrangement for measuring the angle between collimator and scope, and a table for the prism. (Fig. 10.2). The slit and collimator produce parallel light. Rays from a point of an extended source at the front focal plane of a lens will emerge parallel to each other but not parallel to the rays from other object points (Fig. 10.3). By narrowing the slit the beam becomes more parallel, however, the intensity decreases. You will learn in physical optics how to calculate the optimum width of the slit. Here you need only adjust the slit so that it is as narrow as possible while the intensity is adequate. If this seems confusing, do not worry. It is an easy adjustment and will be obvious when you do the experiment. With the slit well adjusted, an essentially parallel beam will emerge from the collimator. This will be deviated and dispersed by the prism (Fig. 10.4). All rays of a given wavelength exit the prism parallel to each other. However, each wavelength is deviated by a slightly different angle. The telescope is adjusted to image parallel rays. Rays parallel to the telescope s axis will image on the crosshair reticle. The ray bundle through a properly adjusted spectrometer is shown in Fig. 10.5. Figure 10.5. Collimated rays through the spectrometer. (Reprinted with written permission from PASCO Scientific).

OPTI 202L - GEOMETRICAL AND INSTRUMENTAL OPTICS LAB Minimum Angle of Deviation: 10-5 This is a very accurate and commonly used method. The angular deviation of a ray traversing a prism depends on the refractive index, prism apex angle A, and the angle of incidence I (Fig. 10.6). A D I > 0 A > 0 D < 0 I Figure 10.6. Geometry for deviation through a prism. According to the following formula, corrected for our sign convention, (Hecht, Optics 2 nd Ed. p. 164): -D = I + Arcsin [(Sin A) (n 2 Sin 2 I) 1/2 (Sin I) (Cos A)] A (10.1) A graph of this equation for a given prism (i.e. a given n and A) is similar to a concave-up parabola. Thus, there is a point where the deviation angle D is a minimum. The minimum angle of deviation is related to the index by (see Hecht, p. 165): n Sin A D Sin 2 A 2 min for I>0, A>0, D<0 (10.2) Note that because n is wavelength-dependent, so is the minimum angle of deviation. To use this technique, one makes a prism out of the material to be measured and aligns it on an autocollimating goniometer (an accurately divided rotation stage with collimated light source designed for alignment). Our spectrometers are essentially this type of instrument. By measuring the prism apex angle A and experimentally finding and measuring Dmin (), n() may be calculated. In this lab, the prism tip and tilt angles have been pre-aligned to save time. The angle of incidence, I, is what is to be varied experimentally.

OPTI 210L - Geometrical Optics Lab 10-6 Procedure You will align and use the spectrometer. There are several critical adjustments which have been preset to save time in this lab. Therefore, DO NOT ADJUST ANYTHING ON THE SPECTROMETER UNLESS INSTRUCTED TO DO SO. #2 Face B A Face A Face C #3 #1 Figure 10.7 Prism table of the student spectrometer Step 1--Focus the Eyepiece on the Crosshair Reticle Plug in the Gaussian eyepiece. Adjust the eyepiece by sliding the eye lens until the crosshairs are in sharp focus. When the crosshairs appear sharp, move your head slightly back and forth. The image should not move. If it does, readjust until the crosshairs are stationary for small head movements (no parallax). Each individual will adjust the eyepiece differently, so once you have done this the same person should proceed with the remaining steps. Then let the next group member try. Step 2 Focus the Telescope at Infinity (Autocollimation, or AutoReflection ) Refer to Fig. 10.7. Rotate the prism table (NOT THE PRISM ITSELF) until face A is perpendicular to the axis of the collimator. Gently lock the prism table in place with the locking screw. Rotate the telescope until it appears to be normal to one of the prism faces, either B or C. Look through the eyepiece and slowly rotate the telescope until you see an image of the crosshairs (light reflected from the prism). The crosshair reticle itself will appear illuminated, and the image reflected in the prism will appear black. Why?

OPTI 210L - Geometrical Optics Lab Fine tune the focus of the telescope until the image of the crosshairs is in sharp focus. At this point the telescope is focused at infinity. Explain. Step 3 Measure the Apex Angle of the Prism Look through the eyepiece and slowly fine tune the telescope rotation until the vertical crosshair and its image overlap. At this point the axis of the telescope is normal to the face of the prism. DO NOT ADJUST OR CHANGE THE PRISM ANGLE IN DOING THIS. Record the position of the telescope using the scale readings in both windows. Rotate the telescope around to the second face of the prism. As you just did, slowly rotate the telescope until the vertical crosshair and its image overlap. Again, record the position of the telescope using the scale readings in both windows. Calculate the telescope rotation angle, T, as the difference in both sets of scale readings. Take the average of both values of T to compensate for (possible slight) machining errors in the prism rotation table. Calculate the prism apex angle A using the formula: 10-7 A = 180 - T (10.3) Step 4 Find the Minimum Angle of Deviation Turn off the Gaussian eyepiece and turn on the Argon source (labeled A ). Unlock the prism table and rotate it until face A is roughly parallel to the axis of the collimator (position face A so it is on the right side of the collimator when looking along the collimator toward the source). Leave the prism table unlocked for the remainder of the experiment. Rotate the telescope counterclockwise toward face A and look for the various spectral lines. They will appear as colored images of the vertical source slit. You will also have to rotate the prism table to see them. Find the brightest red line (696 nm) and position it in the center of the telescope s field of view. Slowly rotate the prism table so that the red line moves to the left in the field of view. At the same time move the telescope to track it, keeping the line in the center of the field of view. At the point of minimum angle of deviation, the red line will appear to stop moving left, remain stationary for a second, then begin moving to the right, similar to a planet moving in retrograde motion. This should all happen within a small enough angle so that the telescope will no longer have to be rotated. The prism is at minimum deviation when the image appears stationary. At this point, lock the prism table in place, so that it can t move (before the next step). Fine tune the telescope rotation so that the red line and vertical crosshair coincide. Record one of the scale readings.

OPTI 210L - Geometrical Optics Lab 10-8 Step 5 Measure the Angular Position of the Source Rotate the telescope so its axis is parallel to the axis of the collimator. At this point you should see the purple image of the vertical source slit in the field of view. Rotate the telescope until its vertical crosshair is centered on the purple image of the undeviated source. Record the angle using the same side of the scale as in the previous step. Step 6 Calculate the Minimum Angle of Deviation Take the difference in angle readings of the spectral line and the source to calculate the minimum angle of deviation. Use the equation for minimum angle of deviation to calculate the refractive index of the prism at 696 nm. Step 7 Measure the Complete Dispersion Curve Replace the Argon source with the Mercury source (labeled Hg). Unlock the prism table. Repeat steps 4, 5 and 6 for the following spectral lines: SPECTRAL LINE COLOR SOURCE WAVELENGTH violet Hg 405 nm blue Hg 436 nm green Hg 546 nm orange (doublet) Hg 578 nm red Ar 696 nm

OPTI 210L - Geometrical Optics Lab 10-9 Plot the refractive indices you measured vs. wavelength (in nm). This is known as a dispersion curve. Each glass type has its own characteristic dispersion curve, measured with high accuracy and published in the form of coefficients to a curve-fit on the measured data. Assuming that the prism you measured is a type of flint glass, use the following dispersion information for SF7 glass to calculate the expected index values at the wavelengths you used. Plot these data on the same graph with your measured values. Formula: n 2 = A0 + A1 2 + A2-2 + A3-4 + A4-6 Coefficients: A0 = 2.6129703 A1 = -8.9265027E-3 A2 = 2.4553061E-2 A3 = 10.7700411E-4 A4 = -2.6551022E-5 (NOTE: wavelengths must be entered in microns in the formula) (10.4) How accurate would the measurement be if you could determine both A and D to 1 second of arc? HINT: See Lab #1 from 201L for the formula.