New Scintillators for the Border Monitoring Equipment

Similar documents
Non-proportionality of organic scintillators and BGO

New Photonis XP20D0 photomultiplier for fast timing in nuclear medicine

Energy Resolution of Scintillation Detectors New Observations

Light yield non-proportionality and intrinsic energy resolution of doped CsI scintillators

Light yield non-proportionality and energy resolution of Lu 1.95 Y 0.05 SiO 5 :Ce and Lu 2 SiO 5 :Ce scintillation crystals

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

Ultra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals

Characterization of the Lanthanum Chloride Scintillation Detector

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

Scintillation Properties of Lu 3 Al 5 O 12, Lu 2 SiO 5 and LaBr 3 Crystals Activated with Cerium

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Improved scintillation proportionality and energy resolution of LaBr 3 :Ce at 80K

Large Area Avalanche Photodiodes in X-rays and scintillation detection

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

Non-proportional response and energy resolution of pure SrI 2 and SrI 2 :5%Eu scintillators

Journal of Asian Scientific Research, 1(3),PP

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

OPPORTUNITY TO JOIN IEEE AND NPSS

Design of a Lanthanum Bromide Detector for TOF PET

Chapter 4 Scintillation Detectors

Non-proportional scintillation response of NaI:Tl to low energy X-ray photons and electrons

Scintillation Products Technical Note

Monte-Carlo Simulation of Response Functions for Natural Gamma-Rays in LaBr 3 Detector System with Complex Borehole Configurations

The Scintillation properties of Pr 3+ doped and Pr 3+, Ce 3+

Efficiency. Calculations for Selected Scintillators. > Detector Counting. Efficiency. > Photopeak Efficiency of Various Scintillation Materials

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 3, JUNE

Design and production of Scintillation Detectors

A new scintillator detector for nuclear physics experiments: the CLYC scintillator

Sample Spectroscopy System Hardware

INORGANIC crystal scintillators are widely used in high

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Measurement of high energy gamma rays with large volume LaBr 3 :Ce scintillators

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Large volume LaBr 3 :Ce detectors and HECTOR +

Scintillation Detectors

arxiv: v1 [physics.ins-det] 29 Jun 2011

The Characterization of new Eu 2+ doped TlSr2I5 Scintillator Crystals

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE

arxiv:nucl-ex/ v1 2 Aug 2006

Physics Dept. PHY-503-SEMESTER 112 PROJECT. Measurement of Carbon Concentration in Bulk Hydrocarbon Samples

Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET

Mass of the electron m 0

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

arxiv: v2 [physics.ins-det] 8 Feb 2013

Radiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors

Radiation Detection and Measurement

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

Investigation of Ce-doped Gd2Si2O7 as a scintillator. Author(s) Kurashige, Kazuhisa; Ishibashi, Hiroyuki; Furusaka, Instructions for use

arxiv:hep-ex/ May 2000

Response Function of the BGO and NaI(Tl) Detectors Using Monte Carlo Simulations

Fast inorganic scintillators - status and outlook -

Improvement of -ray energy resolution of LaBr3:Ce3+ scintillation detectors by Sr2+ and Ca2+ co-doping

Direct WIMP Detection in Double-Phase Xenon TPCs

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

arxiv:physics/ v1 3 Aug 2006

Response function and linearity for high energy γ-rays in large volume LaBr3:Ce detectors

Europium-doped barium halide scintillators for x-ray and -ray detections

Instrumentation and Physics Cases for EURISOL- DF, the next step towards EURISOL

The Best Gamma-Ray Detector

SCINTILLATION DETECTORS AND PM TUBES

MCNP analysis and optimization of a double crystal phoswich detector

The EURITRACK Project: Status of a Tagged Neutron Inspection System for Cargo Containers

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Introduction to Radiation Monitoring

A new timing model for calculating the intrinsic timing resolution of a scintillator detector

Measurement and simulation of proton induced activation of LaBr 3 :Ce

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

PoS(INTEGRAL 2010)107

DETECTORS. I. Charged Particle Detectors

Key words: avalanche photodiode, soft X-ray detector, scintillation γ-ray detector, imaging device PACS: 07.85;95.55.A;85.60.D

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

CsI(Tl) for WIMP dark matter searches

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

LAAPD Performance Measurements in Liquid Xenon

Recent advances and future perspectives of gamma imagers for scintimammography

CapeSym, Inc. Radiation Detection Solutions

Compton suppression spectrometry

Scintillation Detectors

Chapter Seven (Nuclear Detectors)

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

X-ray spectrometry with Peltier-cooled large area avalanche photodiodes

Keywords: scintillator detectors, nonproportionality, gamma-ray detectors, Onsager mechanism, charge carriers, excitons

Quality Assurance. Purity control. Polycrystalline Ingots

X ray Imaging Android [XIA]

GAMMA RAY SPECTROSCOPY

Crystals for the HHCAL Detector Concept Rihua Mao, Member, IEEE, Liyuan Zhang, Member, IEEE, and Ren-Yuan Zhu, Senior Member, IEEE

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

Preparatory experiments for cold-neutron induced fission studies at IKI

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Neutron Spectrometry Using a 7 Li Enriched CLYC Scintillation Detector

DELAYED COINCIDENCE METHOD FOR PICOSECOND LIFETIME MEASUREMENTS

Study of Isospin simmetry using the PARIS detector. Alice Mentana

The fast light of CsI(Na) crystals

arxiv: v2 [physics.ins-det] 15 Dec 2011

Scintillators General Characteristics

Fast detectors for Mössbauer spectroscopy )

Transcription:

New Scintillators for the Border Monitoring Equipment M. Moszynski a a Soltan Institute for Nuclear Studies, PL 05-400 Otwock-Swierk, Poland Performance of new scintillators characterized by a high energy resolution (selectivity), as LaCl 3:Ce and LaBr 3:Ce, and high detection efficiency (sensitivity), as CdWO 4 and CaWO 4, are discussed. Particularly, the properties of LaBr 3 crystal are presented in details. 1. Introduction At present there is a continuous need for highly efficient and good energy resolution (selectivity) detectors to use them in the border monitoring instrumentation to fight illicit trafficking of nuclear materials [1]. There are at least two major technical obstacles: sensitivity and selectivity. The sensitivity is of great importance parameter, which allows finding nuclear material, while the selectivity is required to avoid a misinterpretation of the benign radioactivity as being a threat. As of now, the small hand-held instrumentation utilize scintillation detectors NaI(Tl) and semiconductor detectors CZT. The former one is characterized by a very high detection efficiency but poor energy resolution, while the latter is of better selectivity but lower efficiency due to its small size. New scintillation detectors are needed to significantly improve current border monitoring instrumentation. Particularly, new scintillators as LaCl 3, LaBr 3, CdWO 4 (CWO), and CaWO 4 seem to be good candidates and their advantages and drawbacks should be evaluated. High energy resolution (selectivity) of LaCl 3 and LaBr 3 and the high detection efficiency of CWO and CaWO 4 for high-energy gamma rays can improve the border monitoring. The performances of new scintillators are discussed below with a special emphasis to the LaBr 3 crystal. 2. Scintillators with a High Selectivity Recently new chloride and bromide compounds, as LaCl 3 :Ce [2] and LaBr 3 :Ce [3], showed both a very high light output and good en- Figure 1: The comparison of energy spectra of 662 kev γ-rays from a 137 Cs source, as measured with LaCl 3 and NaI(Tl) crystals under the same gain of spectroscopy amplifier. ergy resolution. The value of 2.9% measured for 662 kev γ-rays from 137 Cs with LaBr 3 scintillator is unequalled [3]. A good density of both crystals equal to 3.86 g/cm 3 for LaCl 3 and 5.3 g/cm 3 for LaBr 3 assure a comparable or better sensitivity 1

2 M. Moszynski Figure 2: Non-proportionality of the light yield of LaCl 3 and NaI(Tl). The curve error is 3%. than that of NaI(Tl). Fast light pulses with the decay time constant of about 25 ns and 18 ns, respectively, allow for high counting rate measurements. 2.1. LaCl 3 :Ce Crystal The LaCl 3 :Ce crystal was proposed first by van Loef et al [2]. In the study [4], the commercial sample of LaCl 3 :(9 ± 1)%Ce with size of 25 25 mm was compared to NaI(Tl). A good light output of 9400±100 photoelectrons per MeV and energy resolution of 4.2 ± 0.2% for 662 kev γ-rays were measured with the LaCl 3 crystal cou- pled to the XP3212 photomultiplier with bialkali photocathode. Below 122 kev, the energy resolution of LaCl 3 was unexpectedly worse than that of NaI(Tl). Figure 1 presents the comparison of energy spectra of 662 kev γ-rays from a 137 Cs source, as measured with LaCl 3 and NaI(Tl) crystals at 3 µs shaping time. Note a very good energy resolution of LaCl 3 of 4.2% in comparison to 6.5% observed with NaI(Tl). The non-proportionality curves for LaCl 3 and NaI(Tl) are shown in Fig. 2. The nonproportionality is defined here as the photoelectron (PHE) number yield measured at specific γ-ray energy relative to the PHE number yield at 662 kev γ-peak. LaCl 3 is clearly superior to NaI(Tl) in terms of non-proportionality. 2.2. LaBr 3 :Ce Crystal LaBr 3 crystals are characterized by a high energy resolution down to 2.8% for 662 kev gammarays from 137 Cs source, as measured with 3 3 LaBr 3 crystal. A high light output above 60000 ph/mev, very good proportionality of the light yield versus gamma ray energy and a high speed of the light pulse with the decay time constant of 18 ns must be pointed out [5,6]. Figure 3 presents a comparison of the energy spectra of Figure 3: A comparison of the energy spectra of 662 kev gamma rays from a 137 Cs source measured with 3 3 LaBr 3 and NaI(Tl) crystals. Courtesy of Saint-Gobain Crystals. Figure 4: A comparison of the non-proportionality curves measured for the LaBr 3 and NaI(Tl) ( 25 31 mm) crystals, respectively.

New Scintillators for the Border Monitoring Equipment 3 3. Scintillators with a High Sensitivity Comparison to BGO and NaI(Tl) Scintillators Figure 5: Number of photoelectrons per MeV versus temperature as measured for the LaBr 3 coupled to the XP2020. On the right ordinate the relative gain variation is scaled, normalized to unity at 20 C. The open triangles represent the number of photoelectrons corrected for the relative QE variation at 360 nm wavelength. 662 kev gamma rays from a 137 Cs source measured with 3 3 LaBr 3 and NaI(Tl) crystals. Note a superior energy resolution of the new crystal and its better full energy peak efficiency. Figure 4 presents a comparison of nonproportionality characteristics of LaBr 3 and NaI(Tl) crystals. A much better proportionality of LaBr 3 allows a simpler energy calibration of gamma spectrometers and, moreover, it is reflected in the superior energy resolution. A high temperature stability of the light output of LaBr 3 crystal corresponding to about 0.01%/ C was recently measured in the temperature range from 30 C to 60 C [7](see Fig. 5). A high light output and a fast light pulse of LaBr 3 crystal allowed getting an excellent time resolution. Figure 6 presents time spectra measured with 1 1 LaBr 3 coupled to the XP20D0 PMT in relation to the BaF 2 crystal [8]. No doubt that the LaBr 3 crystal is the scintillator of a choice for all equipment used in the border monitoring, when gamma spectrometry is needed. It includes also the neutron activation methods addressed to detect explosives in the luggage and big trucks. New high-z scintillator detectors are needed to significantly improve current border monitoring instrumentation utilizing plastic detectors, as well as the development of highly efficient hand-held instrumentation. BGO, widely used high-z scintillator, suffers because of a low light yield and in consequence a poor energy resolution. CdWO 4 (CWO) [9,10] and CaWO 4 (CaWO) [11,12] are candidate to be used for this purpose. An application of CWO and CaWO in the gamma spectrometry is limited because of a long main decay time constant of the light pulses, which does not allow measurements at high counting rates. Both crystals belong to the group of very slow scintillators with a long decay time constant of the light pulse of 14 µs for CWO [9] and 9µs for CaWO [11,12]. However, in the border monitoring equipment, one is looking for traces of gamma rays emitted by well-shielded radioactive sources. Thus, high rate capabilities of the detectors are less important. Figure 7 shows the energy spectra of 662 kev γ-rays from a 137 Cs source measured with a small CWO crystal of 10 10 3 mm 3 and with a 25 mm Figure 6: Time spectra of 60 Co and 22 Na γ-rays detected in the LaBr 3 crystal coupled to the XP20D0, measured in relation to the BaF 2 detector.

4 M. Moszynski Figure 8: A comparison of the non-proportionality curves measured for the small CWO and BGO crystals. The curve for BGO follows that of Ref. [14]. Figure 7: Energy spectra of 662 kev γ-rays from a 137 Cs source, as recorded with the 10 10 3 mm 3 CWO (bottom panel) and with the 25 mm 30 mm NaI(Tl) (upper panel). An escape peak of K x-rays of Tungstate is seen at the 662 kev peak in the CWO spectrum. in diameter and 30 mm high NaI(Tl). Note the high energy resolution of 6.6 ± 0.2% for the 662 kev peak obtained with the CWO, which is comparable to that of NaI(Tl). Note also the comparable photofractions of 26% and 23% in both spectra for the CWO and the NaI(Tl) crystals, respectively, while the volume of the NaI(Tl) crystal is 50 times larger. Figure 8 presents the non-proportionality characteristics of the small CWO in comparison to that of a BGO crystal, according to Ref. [10]. The non-proportionality is defined here as the ratio of the photoelectron yield measured for photopeaks at a specific γ-ray energy relative to the yield at 662 kev γ-peak [13]. Note a comparable shape of the measured curve for CWO to that reported in Ref. [14] for BGO. The study of the small CWO crystals showed a high light output of 27300±2700 ph/mev and an energy resolution of 6.6 ± 0.2% for the 662 kev γ- rays from a 137 Cs source, both placing the CWO crystal within bright scintillators with a good energy resolution. In the case of CaWO, its high light output of 4800±200 phe/mev and a good energy resolution of 6.6±0.2% for 662 kev gamma rays from a 137 Cs source have to be noted, as measured for the small samples coupled to the XP3212 photomultiplier. There is no doubt that due to the high energy resolution, the CWO and CaWO crystals can replace the BGO in several applications. REFERENCES 1. R. Arlt, et al., IEEE Nucl. Sci. Symp. Conference Record, 15-20 Oct. 2000, IEEE vol. 1, pp. 4/18-4/23 2. E.V.D. van Loef, P. Dorenbos, C.W.E. van Eijk, Appl. Phys. Lett., 77, 2000, 1467-1468.

New Scintillators for the Border Monitoring Equipment 5 3. E.V.D. van Loef, et al.,appl. Phys. Lett., 79, 2001, 1573-1575. 4. M. Balcerzyk, M. Moszynski, M. Kapusta, Comparison of LaCl 3 :Ce and NaI(Tl) scintillators in γ-ray spectrometry, Nucl. Instrum. Meth., A537(2005)50. 5. P. Dorenbos, J.T.M. de Haas, and C.W.E. van Eijk, IEEE Trans. Nucl. Sci., vol. 51, no. 3, pp. 1289-1296, June 2004. 6. A. Syntfeld, et al., IEEE Trans. Nucl. Sci, in press. 7. M. Moszynski, et al., Nucl. Instr. Meth. S568(2006)739. 8. M. Moszynski, et al., Nucl Instr. Meth., A567(2006)31. 9. C.L. Melcher, et al., IEEE Trans. Nucl. Sci., Vol. 36, No. 1, pp. 1188-1192, Febr. 1989. 10. M. Moszynski, et al., IEEE Trans. Nucl. Sci. 52(2005)3124. 11. Yu.G. Zdesenko, et al, Nucl. Instr. Meth. A538(2005)657. 12. M. Moszynski, et al., Nucl. Intstr. Meth., A553(2005)578. 13. W. Mengesha, et al. IEEE Trans. Nucl. Sci., 45, 1998, 456-460. 14. M. Moszynski, et al., IEEE Trans. Nucl. Sci., 51(2004)1074.