LaBr 3 (Ce) detector and PMT tests at IPN Orsay

Similar documents
New Photonis XP20D0 photomultiplier for fast timing in nuclear medicine

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Ultra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

Design of a Lanthanum Bromide Detector for TOF PET

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

arxiv:physics/ v1 3 Aug 2006

Timing and Energy Response of Six Prototype Scintillators

Timing resolution measurement of a 3 Lanthanum Bromide detector

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Studies of Hadron Calorimeter

Neutron Response of LaBr 3 :Ce and CsI:Na Phoswich Crystal Scintillators for PARIS

ORTEC AN34 Experiment 10 Compton Scattering

Figure 1. Decay Scheme for 60Co

Hands on Project: Large Photocathode PMT Characterization

ANAIS: Status and prospects

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

SCINTILLATION DETECTORS AND PM TUBES

Light yield non-proportionality and intrinsic energy resolution of doped CsI scintillators

DELAYED COINCIDENCE METHOD FOR PICOSECOND LIFETIME MEASUREMENTS

José Antonio Briz Monago, M. Carmona-Gallardo and. M.J.G. Borge, A. Perea, O. Tengblad, M. Turrión

PARIS : A versatile detection array for low and high energy gamma-rays. Olivier Dorvaux, IPHC/University of Strasbourg for the PARIS collaboration

Development of a 3D-Imaging Calorimeter in LaBr 3 for Gamma-Ray Space Astronomy

New Scintillators for the Border Monitoring Equipment

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

arxiv: v1 [physics.ins-det] 29 Jun 2011

Dual readout with tiles for calorimetry.

Deliverable D10.1. WP10 JRA04 Innovative solutions for nuclear physics detectors

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Large volume LaBr 3 :Ce detectors and HECTOR +

Bremsstrahlung and Ion Beam Current Measurements with SuSI ECR Ion Source

Characterization and Monte Carlo simulations for a CLYC detector

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

Non-proportionality of organic scintillators and BGO

R&D on Astroparticles Detectors. (Activity on CSN )

Scintillation Detector

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

LSO/LYSO Crystal Development Ren-yuan Zhu

GRAPE A Balloon-Borne Gamma-Ray Polarimeter

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

High energy gamma production: analysis of LAL 4-mirror cavity data

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Mass of the electron m 0

Direct WIMP Detection in Double-Phase Xenon TPCs

Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET

LAB 4: Gamma-ray coincidence spectrometry (2018)

Study of Isospin simmetry using the PARIS detector. Alice Mentana

A NEW GENERATION OF GAMMA-RAY TELESCOPE

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

RESPONSE OF A NAI(TL) SCINTILLATION DETECTOR IN A WIDE TEMPERATURE INTERVAL

Light yield non-proportionality and energy resolution of Lu 1.95 Y 0.05 SiO 5 :Ce and Lu 2 SiO 5 :Ce scintillation crystals

ELECTRONIC TECHNIQUES IN TIMING MEASUREMENTS FOR NUCLEAR STRUCTURE

High-efficiency and fast-timing scintillators

CHIPP Plenary Meeting University of Geneva, June 12, 2008 W. Lustermann on behalf of the AX PET Collaboration

Development of a High Precision Axial 3-D PET for Brain Imaging

1 of :32

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Preparatory experiments for cold-neutron induced fission studies at IKI

Angular and energy distributions of the prompt fission neutrons from thermal neutron-induced fission of 239 Pu

Charge collection in PET detectors

Gamma Spectroscopy. Calligaris Luca Massironi Andrea Presotto Luca. Academic Year 2006/2007

Chapter 4 Scintillation Detectors

A new timing model for calculating the intrinsic timing resolution of a scintillator detector

Timing and cross-talk properties of BURLE multi-channel MCP-PMTs

Development of a new MeV gamma-ray camera

The Generalized Centroid Difference Method

XMASS: a large single-phase liquid-xenon detector

Investigation of fast neutron spectroscopy capability of 7 Li and 6. Li enriched CLYC scintillator for nuclear physics experiments

Status of KIMS-NaI experiment

Detection of γ-rays from nuclear decay: 0.1 < E γ < 20 MeV

A method to measure transit time spread of photomultiplier tubes with Cherenkov light

Energy Resolution of Scintillation Detectors New Observations

Measurements of the Minimum Bending Radius of Small Diameter Scintillating Plastic Fibres

Characterization of the Lanthanum Chloride Scintillation Detector

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Factors Affecting Detector Performance Goals and Alternative Photo-detectors

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

1420 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 57, NO. 3, JUNE /$ IEEE

Absolute activity measurement

Radiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors

arxiv: v2 [physics.ins-det] 8 Feb 2013

ABSTRACT. Gamma-ray spectroscopy in high count rate applications can be challenging with inorganic

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

Measurement of high energy gamma rays with large volume LaBr 3 :Ce scintillators

Response function and linearity for high energy γ-rays in large volume LaBr3:Ce detectors

AN34 Experiments in Nuclear Science Laboratory Manual Fourth Edition

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

CapeSym, Inc. Radiation Detection Solutions

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

OPPORTUNITY TO JOIN IEEE AND NPSS

MoNA: the Modular Neutron Array

ORTEC Experiment 19. Gamma-Ray Decay Scheme and Angular Correlation for 60 Co. Equipment Required. Purpose

The Kinematics and Electron Cross Sections of Compton Scattering

A gamma-gamma coincidence spectrometer for nuclear attribution and safeguard applications

PHYS 3446 Lecture #12

PoS(INTEGRAL 2010)107

Transcription:

LaBr 3 (Ce) detector and PMT tests at IPN Orsay G. Hull, T. Zerguerras, I. Matea, J. Peyré, J. Pouthas, M. Josselin, M. Niikura August 31, 2010 Abstract By the end of 2010, the PARIS collaboration should decide on the composition and configuration of the calorimeter that will be part of the SPIRAL2 instrumentation. In order to do so, intense studies are under way on scintillators like LaBr 3(Ce) in stand alone mode or coupled with CsI(Na) or NaI(Tl) crystals in a phoswich configuration. We present here the energy and time resolution results obtained with standard sources for three single LaBr 3(Ce) crystals of different sizes, for a LaBr 3(Ce)+NaI(Tl) phoswich and a LaBr 3(Ce)+CsI(Na) phoswich. 1 Introduction The main goal of these measurements is to investigate the alteration of the energy resolution of a LaBr 3 (Ce) crystal when optically coupled with another type of crystal, as the light collection is made only at one end of the phoswich and the characteristics of the crystal coupled with LaBr 3 (Ce) can play an important role in the energy/time resolution. We have also measured the energy and time resolution of single LaBr 3 (Ce) of different sizes. Additionally, we wanted to measure also the influence of PMT crystal coupling and of the choice of digitizer (ADC or QDC) on the obtained resolution. 2 Energy resolution measurements The standard sources used for the tests were 22 Na, 60 Co and 137 Cs. In the case of the phoswich crystals, we have placed the sources on the side, on one extremity for the LaBr 3 (Ce) energy resolution measurement and on the other extremity (next to the phoswich PMT connection) for the CsI(Na)/NaI(Tl) crystals. For one set of measurements with the phoswich crystals, the Cs source was collimated and placed at different distances on the side of the scintillators, in order to check the homogeneity of the crystals coupled with LaBr 3 (Ce). In the following, we describe the scintillators and the PMTs used for these measurements, together with the electronic set-up. 2.1 Scintillators and PMTs description Details on the scintillators and the PMTs used for the present study are presented in Tables 1 and 2. In the following, we refer to the crystals by using 1

the names given in Table 1. The B380 2 has the same size as the LaBr 3 (Ce) in the two phoswich and so it will be used for comparison. Table 1: Description of the crystals used for the tests. Crystal name B380 1 B380 2 B380 3 PNaI PCsI Dimensions Φ1 x1 1 x1 x2 2 x2 x4 B380: 1 x1 x2 NaI(Tl): 1 x1 x6 B380: 1 x1 x2 CsI(Na): 1 x1 x6 We have used 4 different cylindrical PM tubes: Photonis XP5300B, considered as reference and characterized by a very good quantum efficiency (36%), Photonis XP2282, 2 PMT Hamamantsu R2083, and an 1 Hamamatsu R7899 (not covering the full surface when in contact with any of the crystals). Table 2: List of the PM Tubes used for the energy resolution measurements. PMT Dimensions Sensitivity in blue Dynode output (µa/lmf) XP5300B 3 14.6 5 XP2282 2 9.0 8 R2083 2 10.5 7 R7899-01 1 10.2 anode reading After the analysis of different measurements, we have realized that the Photonis XP2282 tube used had a very bad sensitivity in blue (with respect to the Photonis data sheet) that influenced the energy resolutions obtained. This is very likely because the PMT is quite old and it served in many experiments. 2.2 The electronic setup We used standard NIM and CAMAC electronics. For each PMT, the divider was designed with an anode and a dynode output. The dynode signal was connected to a Cremat (Charge) Preamplifier CR-113 [2], 1.5mV/pC, and then to an ORTEC Amplifier 572 and an ORTEC ADC 811 for energy measurements. We selected a shaping time of 0.5 µs for measurements of the LaBr 3 (Ce) crystal resolutions and of 3 µs for the measurement of the energy resolution of NaI(Tl) and CsI(Na) crystals. The anode signal was connected to a Voltage Preamplifier with two outputs: one going to a ORTEC TFA 454 to start the gates for the coding in ADC/QDC and the other into a Lecroy QDC 2249A for charge integration. We have used the QDC for to purposes. The first is the comparison of the energy resolutions, 2

obtained by using peak sensing and charge integration method; the second is the rejection of events where gamma-interactions are detected either in both LaBr 3 (Ce) and NaI(Tl)/CsI(Na) crystals or in NaI(Tl)/CsI(Na) alone. Two gates where used for the signal integration: a short gate G1 (100 ns) dedicated to the LaBr 3 (Ce) and a longer gate G2 (200 ns), delayed by 120 ns with respect to G1, to measure a possible contribution of the NaI(Tl)/CsI(Na) to the phoswich signal. 2.3 On energy resolution and homogeneity of the CsI(Na) and NaI(Tl) crystals The energy resolution of the NaI(Tl)/CsI(Na) crystal associated with the LaBr 3 (Ce) in the phoswich configuration is also a critical parameter to be considered. When putting the 137 Cs source collimated on the side next to the connection with the PM tube, the energy resolution was 6.39 % for the NaI(Tl) crystal and 8.35 % for the CsI(Na) crystal. If we don t use the collimation, the measured energy resolution become 6.54 % for NaI(Tl) and 10.97 % for CsI(Na). The difference between the results with and without collimation in the case of CsI(Na) comes from the inhomogeneity of the CsI(Na) crystal that was measured to be of 25.4 % (the shift of the photopeak when moving longitudinally from an extremity to the other of the crystal). For the NaI(Tl) crystal, the inhomogeneity was measured to be 8.2 %. 2.4 Results The raw data were analyzed with the ROOT package. The results are summarized in the table 3. We give in this table only the energy resolution with the ADC, as the results from ADC and QDC are compatible. Table 3: LaBr 3 (Ce) energy resolution η(e), at 662 kev (%). XP5300B XP2282 R2083 R7899 B380 1 3.09 3.95 3.38 3.38 B380 2 3.15 4.07 3.49 3.76 B380 3 3.04 4.98 4.03 6.9 PNaI 3.79 5.10 4.21 5.45 PCsI 4.51 6.19 4.91 7.19 Not relevant: surface of the PMT is less than 1/4 of the crystal surface As one can see, the best results are obtained with the XP5300B PMT. This is not surprising because this PMT is one of the best existing on the market and suitable for these measurements. But these results should be taken only as reference and one should not expect to obtain these energy resolutions for the PARIS calorimeter. Both XP2282 and R2083 are 2 diameter PM tubes but for the following discussions we ll only use the results obtained with R2083 for reasons specified earlier concerning XP2282. We compared the energy resolutions obtained using 3

R2083 with the reference ones (XP5300B) for all the crystals (excluding the case of B380 3 that is not fully covered by R2083). From table 4, second column, one can conclude that the measurements with one PMT can safely be compared with each other and that they reflect the crystal resolution. If we compare now the results obtained with R7899 PMT with the reference ones (third column in table 4), it appears that there is a geometrical effect (the R7899 PMT does not cover the entire contact surface with the crystal) coupled with the presence of intermediate crystal (in the case of the phoswichs) that decreases the energy resolution between a single crystal and a phoswich. We see also a smaller ratio for the case of PCsI, compared with PNaI. The first value in this column is NR (not relevant) because the PMT has the same size as the crystal. If we choose now to compare the energy resolutions of B380 2, PNaI and PCsI when measured with R7899 (this geometrical configuration is somehow similar to what PARIS might look like), we can see from the fourth column of table 4 the decrease in energy resolution when passing from single crystal to phoswich of 45 % for PNaI and of 91 % for PCsI. Table 4: Comparison of different results listed in table 3. η ref /η R2083 η ref /η R7899 η B380 2 /η i (with R7899) B380 1 91.4 % NR B380 2 90.3 % 83.8 % 1.0 B380 3 NR NR PNaI 90.0 % 69.5 % 0.69 PCsI 91.8 % 62.7 % 0.52 η ref is the energy resolution obtained with XP5300B Not Relevant 3 Time resolution measurements For the time resolution measurements, we have used a different test bench. Its composition, the analysis procedure and the results will be presented here. 3.1 Scintillators and PMTs description At the present time, we have results on time resolution only for the B380 1 and B380 3 crystals. We intend to extend the measurements to PNaI crystal. For these measurements, each crystal was connected to only one PMT: B380 1 with a Photonis XP20D0 PMT and B380 3 with a Photonis XP2282 PMT (different from the one used for the energy resolution measurements but from same generation). 4

3.2 The electronic setup Each PMT divider had a dynode and an anode output. The dynodes were used for the energy information whilst the anodes were connected to a Constant Fraction Discriminator (Enertec 7174). From the discriminator, the logic signals of each crystal chain were taken to the start/stop inputs of an ORTEC TAC 567 module, for the time resolution measurement. The energy (from the dynodes) and the time signals were coded by an ORTEC ADC 811. The ADC gate was started by the coincidence between the two crystal chains provided by a Lecroy Coincidence Unit 625. 3.3 Analysis procedure In order to obtain the intrinsic resolution of each crystal, we have measured coincidences between the two crystals using 22 Na and 60 Co collimated sources (to avoid backscattering events). By selecting one energy in one crystal and different energies in the second crystal, we could obtain the time resolution curve as a function of the energy for the second crystal. A quadratic function of the inverse of the energy was adjusted to the experimental data following the expression: f(e) = a 2 + b 2 /E (1) assuming that the resolution goes as the square root of the energy. The coefficient b is also given in the table 5. Using this parameter, the intrinsic time resolution can be deduce for a given energy. The a coefficient is related to the time resolution of the partner detector at the selected energy. 3.4 Results The intrinsic time resolution results are listed in table 5. Table 5: LaBr 3 (Ce) intrinsic time resolution (ps) @511 kev @1173 kev @1332 kev b coef (ps) (ps) (ps) (ps kev ) B380 1 208(9) 137(6) 129(5) 4700(200) B380 3 499(35) 329(23) 309(22) 11269(800) The result for B380 3 has to be further investigated, as the PMT used (XP2282) might not have (due to its age) a good quantum sensitivity and thus can give a worst time resolution than expected. 4 Conclusions We have measured the energy resolution of 3 LaBr 3 (Ce) crystals of different sizes and of 2 phoswich crystals that belong to the PARIS collaboration. These measurements were performed with different PMTs in order to determine the 5

energy resolution decrease when the light is not entirely collected from the crystal. We have also measured the energy resolution of each crystal composing the two phoswichs. The time resolution for selected couples of crystal and PMT were also investigated. By comparing the energy resolution results for B380 2, PNaI and PCsI, we see a decrease in the energy resolution when going from single crystal to phoswich crystal and that the NaI(Tl) phoswich has a better energy resolution that the CsI(Na) phoswich. The difference in energy resolution between PNaI and PCsI was also investigated and turned out to be due to the inhomogeneity of the long crystal attached behind LaBr 3 (Ce). These inhomogeneities can go up to 24 % and, consequently, degrade LaBr 3 (Ce) and NaI(Tl)/CsI(Na) crystal resolutions. The time resolutions obtained for the B380 1 crystal are compatible with the ones published in literature [1]. We also intend to measure the time resolution using the Hammamatsu R2083 PMT. We would like also to measure the time resolution of the PNaI phoswich with the same test bench and to see how much the time resolution is degraded when going from cylindrical PMTs to square PMTs. Also, we plan to make energy resolution measurements with a Lecroy Oscilloscope 715 Zi for the 5 crystals that were tested. This is important to trigger the decision on the best electronic to be used with PARIS detector. References [1] Moszynski et al. Nuclear Instruments and Methodes A567, page 31, 2006. [2] www.cremat.com. 6