Modern Electrical Diagnostics for Metal Oxide Surge Arresters

Similar documents
Keywords- Metal Oxide Surge Arrester, Model, Transient, Laboratory Experiment, Simulation.

Temperature and Field Dependence of Field Grading Tubes for Medium Voltage XLPE Cable Joints

Modeling of Transmission Line and Substation for Insulation Coordination Studies

Advanced Technique for Dielectric Analyses

OR Explain thermal breakdown in solid dielectrics. How this mechanism is

HIGH ENERGY DENSITY CAPACITOR CHARACTERIZATION

Evaluation of the risk of failure due to switching overvoltages of a phase to phase insulation

World Academy of Science, Engineering and Technology

Analysis of Very Fast Transients in EHV Gas Insulated Substations

Film Capacitors. EMI suppression capacitors. Date: June 2018

Experiment FT1: Measurement of Dielectric Constant

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Diagnosis of Electrical Performance and Aging Behavior of Transformer Dielectrics

INSTITUTE OF AERONAUTICAL ENGINERING DUNDIGAL ELECTRICAL AND ELECTRONICS ENGINEERING

INSTITUTE OF AERONAUTICAL ENGINERING DUNDIGAL ELECTRICAL AND ELECTRONICS ENGINEERING

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Fatima Michael College of Engineering & Technology

An Innovative Simple Test Circuit for Single-Phase Short Circuit Making Test of High-Voltage Switching Devices

Volker Hinrichsen Group 33 Germany, Reg.-No. 382 Pref. Subj. No. 1, Qu. 5.4

Effect of High Voltage Impulses on Surface Discharge Characteristics of Polyethylene

Modeling of Partial Discharge Mechanisms in Solid Dielectric Material

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Electro - Principles I

Insulation Resistance and Polarization of Rotating Machines

Degradation Analysis of Metal Oxide Varistors under Harmonic Distortion Conditions

CHECKING OF POLARIZED AND DEPOLARIZED CURRENTS FOR THE ELECTRICAL EQUIPMENTS, IN ORDER TO DETERMINATE THE STATE OF INSULATION AND ITS HUMIDITY CONTENT

Identification File of Type ZE64G23

TD-102. HAEFELY HIPOTRONICS Technical Document

ZNR Transient/Surge Absorbers (Type E)


The Impact of Metallized Electrodes on High Energy Density Pulse Power Capacitors

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

Energy Stored in Capacitors

PD Analysis in Cylindrical Void With Respect To Geometry of the Void

IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 19, NO. 3, JULY Tapan K. Saha, Senior Member, IEEE, and Prithwiraj Purkait, Member, IEEE

Comparison of Partial Discharge Characteristics for Different Defect Types in SF 6 Gas Insulation System

I n many cold-climate regions of the world, overhead

THE APPROACH TO THE ANALYSIS OF ELECTRICAL FIELD DISTRIBUTION IN THE SETUP OF PAPER INSULATED ELECTRODES IN OIL

SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM

Studies on hyper scaling dielectric loss of grading capacitors of 500kv breakers

Finite Element Method Application in Analyzing Magnetic Fields of High Current Bus Duct

Impedance relay and protection assemblies

Simulation of Partial Discharge in Solid Dielectric Material

Thermal and temperature cycling tests on solid dielectric switches, interrupters, and reclosers

Hydra Fault Current Limiting HTS Cable to be Installed in the Consolidated Edison Grid

O Plus Dry Bushing 69 kv system, 350 kv BIL, 3000 A. Table of contents

High Voltage Capacitors Designed to Avoid Catastrophic Failure Modes

Finite Element Modeling and Examination of Axisymmetric Thermal State of the Overvoltage Suppressor

COMPARATIVE EVALUATION OF BREAKDOWN STRENGTH OF NATURAL ESTERS AND MINERAL OIL

Tailoring of new Field Grading Materials for HVDC Systems. Dipl.-Ing. Maximilian Secklehner Rashid Hussain, M.Sc.

Dimension OD±1. General Technical Data. Technical Characteristics GB IEC252:1992 Operating temperature -25 ~+70. Capacitance Tolerance

Research on On-line Monitoring of Insulation of Metal Oxide Surge Arrester

TEST CERTIFICATES OR REPORTS ISSUED BY VEIKI-VNL LTD.

Fault Calculation Methods

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

Power Engineering Institute Warsaw University of Technology

with embedded electrode

STUDIES ON LIGHTNING CHARACTERISTICS

A Novel Optimized Design for Busbar Structures using Finite Element Methods

Comparing Various Moisture Determination Methods for Power Transformers MAIK KOCH*, MICHAEL KRÜGER, STEFAN TENBOHLEN

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

TRANSIENTS POWER SYSTEM. Theory and Applications TERUO OHNO AKIH1RO AMETANI NAOTO NAGAOKA YOSHIHIRO BABA. CRC Press. Taylor & Francis Croup

UNIT I - INTRODUCTION SYLLABUS

Status and Progress of a Fault Current Limiting HTS Cable To Be Installed In The Consolidated Edison Grid

Optimization of High Voltage Arc Assist Interrupters

Comparative Study on Conductivity Using Polarization and Depolarization Current (PDC) Test

EPRI Lightning Protection Design Workstation

An Optimised High Current Impulse Source

Modeling of Power System Components During Electromagnetic Transients

JWG A2/D1.41 HVDC transformer insulation: Oil conductivity 1

CAPACITANCE. Figure 1(a). Figure 1(b).

OBSERVATION OF DIELECTRIC PARAMETERS AT GENERATOR STATOR WINDINGS UNDER CHANGING ENVIRONMENTAL CONDITIONS

The Experimental Determination of the Maximum Continuous Operating Voltage for a ZnO Based Varistor

MME 467: Ceramics for Advanced Applications

Multilayer Varistor for ESD pulse,burst pulse

A3-107 INCREASED PERFORMANCE OF CAPACITOR BANK CIRCUIT BREAKERS BY CONTROLLED OPENING

Analyses of characteristics of spatial lightning electromagnetic field at different horizontal distances and observation point heights

Code No: RR Set No. 1

Capacitors are devices which can store electric charge. They have many applications in electronic circuits. They include:

A Roadmap for Evaluation of Lightning Elimination Technologies

Transduction Based on Changes in the Energy Stored in an Electrical Field

Mitigation of Distributed Generation Impact on Protective Devices in a Distribution Network by Superconducting Fault Current Limiter *

Multilayer Varistor for ESD pulse

Thermal and Mechanical Properties of EPR and XLPE Cable Compounds

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Measurement of the electric field at the near field radiating by electrostatic discharges

Varistors to

Chapter 2: Capacitors And Dielectrics

iclicker A metal ball of radius R has a charge q. Charge is changed q -> - 2q. How does it s capacitance changed?

IEC Type Test Report Report No. EU1527-H-00.1 PH3 Series Polymer-housed Arrester 10,000 A Line Discharge Class 3

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

THE EARLY STREAMER EMISSION PRINCIPLE DOES NOT WORK UNDER NATURAL LIGHTNING!!

Modeling of Polarization in Oil-Paper Insulation Using Recovery Voltage Measurements

Suppressor film capacitor Highlight and Application in Series with the main

DETERMINATION OF THE DIELECTRIC STRENGTH OF LPS COMPONENTS BY APPLICATION OF THE CONSTANT-AREA-CRITERION

MTC-500, MTK-500, MTA-500 Dual SCR Power Module

THE EXPERIMENTAL DETERMINATION OF THE MAXIMUM CONTINUOUS OPERATING VOLTAGE FOR A ZnO BASED VARISTOR

The drive to make devices smaller and faster

Electricity and Magnetism. Capacitance

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Transcription:

1 Modern Electrical Diagnostics for Metal Oxide Surge Arresters K. P. Mardira, Student Member, IEEE, and T. K. Saha, Senior Member, IEEE Abstract The aim of this study is to propose simple and reliable techniques to assess the condition of metal oxide arrester based on the dielectric response techniques. A number of modern electrical diagnostics for Metal Oxide Surge Arrester (MOSA) are discussed in this paper. The techniques included return voltage, decay voltage and polarisation/depolarisation current measurement. The single and multipulse current (8/20µs) was used to artificially degrade the MOSA. The before and after diagnostic results of the new techniques are presented and interpreted. Finally, the correlation of different diagnostic results are discussed and compared to the existing techniques. Index Terms Decay Voltage, Metal Oxide Surge Arrester, Polarisation/Depolarisation Current, Return Voltage. I. INTRODUCTION Gap-less Metal Oxide Surge Arrester (MOSA) has been available in the market for many years since it was first introduced in the 1970 s. Its primary function is to protect all other network in the system against various electrical overstresses. The protection level of MOSA is rapidly developed to meet the withstand requirements such as highenergy absorption capability, current withstand level and voltage stress. However, these fast developments are not accompanied with the development of better techniques to asses MOSA condition. A large number of low-voltage MOSAs are mounted in the distribution system to protect transformers and other accessories. It would be impossible to test every arrester in a distribution system. Very often testing of a small number of suspected arresters could provide meaningful status of a large number of arresters in the similar operating environment. Substation class arresters can be tested at the same time when the substation transformer is disconnected from the network to conduct maintenance. However, the accurate information K.P. Mardira is with School of Information Technology and Electrical Engineering, The University of Queensland, St Lucia, Brisbane - Australia (e-mail: mardira@itee.uq.edu.au). seems impossible to obtain with the existing diagnostic techniques (IEC, ANSI, AS, etc) which in general only provide the pass/fail condition for MOSA without knowing their degree of degradation. Many investigations are conducted recently to provide better and meaningful interpretation of insulating material condition. The new diagnostic techniques such as, Return Voltage Measurement, Polarisation/Depolarisation Current, and Decay Voltage have been increasingly used in the diagnostic of insulating materials such as cables and transformers. Since the MOSA is an insulator at normal conditions (below its rated voltage), the effect of polarisation and depolarisation of its dipole within the insulation can be monitored. In this paper, the new diagnostic techniques are discussed and the relevant test procedures are presented. A number of MOSAs are first artificially degraded by single and mutipulse currents of 8/20µs. The findings from systematic experiments with the purpose to assess the conditions of MOSA are described. The diagnostic results of the new proposed techniques are discussed and compared to those from the existing Australian Standard AS. 1307.2 1996 Surge Arrester Part 2: Metal Oxide Surge Arresters without Gaps for AC systems [1]. Finally, this paper presents the interpretation of different diagnostic technique results and their correlation to a number of existing methods. A. Return Voltage II. THEORY Return voltage (RV) measurements are now increasingly used in the diagnosis of insulating materials and devices like cables and transformers. Since a conventional surge arrester is an insulator at normal conditions (below its rated voltage), the effect of return voltage can then be monitored. The return voltage is based on the polarisation and subsequent depolarisation of dipoles within the insulating material as well as on the charging and discharging of grain boundaries and space charge effect [2]. The return voltage measurement comprises three steps. Fig. 1 shows the typical steps of return voltage. T.K. Saha is with School of Information Technology and Electrical Engineering, The University of Queensland, St Lucia, Brisbane Australia (e-mail :saha@itee.uq.edu.au) 1. Charge the tested object for a pre-selected time (tc) with a

2 DC voltage, which is much lower than the rated voltage. 2. Discharge the tested object for a short period of time (normally half of the charging time, td = ½ tc). 3. Measure the open circuit voltage build up across the test object (V). There are three important parameters that may characterise the condition of insulation. They are peak maximum return voltage, time to peak maximum return voltage (central time constant (ctc)) and the initial slope (slope of return voltage curve for first few seconds)[3,4]. Fig. 2 The Decay Voltage After charging the insulation for a short period of time, the decay voltage (Ud) is measured. This is usually over several hundred seconds and excites the polarisation process using the DC voltage (Uc). When the insulation connected from the voltage source, the voltage curve arises from the charge electrodes and discharging through the internal insulation resistance [5]. The steepness S d of the initial tangent of the decay voltage is directly proportional to the specific conductivity γ of the insulating materials [5,6]. S d = [du/dt] t=0 = γ E 0 /ε 0 (1) Where E 0 [V/cm] = field strength during the charging period γ [A/V.s]= specific conductivity of insulation, and ε 0 [A.s/V.cm] = 8.854 e-14 In diagnostic testing equation (1) can be normalised to S d = γ Uc/ε 0 (2) Where U C /d = E 0 and d is the length of arrester in centimeter. This equation (2) then can be used either by calculating the specific conductivity or applying the steepness as a quantity of the condition of the insulation. C. Polarisation/Depolarisation Current Fig. 1. The Return Voltage B. Decay Voltage The voltage response method uses the phenomenon of decreasing voltage after switching off known as the decay voltage. The primary purpose of the decay voltage measurement is to investigate the ohmic conductivity of insulating materials. The initial tangent of the voltage curves is used as the parameters characteristic of the condition of insulation. Fig. 2 depicts a graphical representation of the decay voltage curve. This method is to quantify the dielectric response of the insulating materials by allowing the observations of the polarisation development in time when DC voltage is applied. This polarisation is proportional to the intensity of the electrical field and by measuring the current, polarisation process then can be observed. When the DC voltage is removed, a reversed polarity current known as the depolarisation current is obtained. Fig. 3 is a typical polarisation/depolarisation current curves results of DC charging and consequently discharging period. Fig. 3. Polarisation/ Depolarisation Current Curves These two currents can be used to determine the response

3 function f(t) and the conductivity (σ ) of the insulating materials. If we apply the system to a step voltage at t =0 the charging and discharging current is given by [7] J(t) polarisation = E(t) (σ + ε 0. f(t) ) (3) J(t) depolarisation = -ε 0 E(t) ( f(t) f(t + t polarisation )) (4) The field strength E(t) can be considered as generated by an external voltage Uc(t). Then the corresponding current I(t) can be rewritten from equation (3) & (4) I(t) polarisation = U c (t)c 0 (σ /ε 0 + f(t)) (5) I(t) depolarisation = -U c (t) C 0 (f(t) f(t+t polarisation )) (6) where C 0 is the vacuum capacitance of the arrester and t polarisation is the length of the charging period. As f(t) is a decaying function the second term in equation (6) can be neglected for large value of t polarisation and the depolarisation current becomes proportional to the response function f(t). In order to solve the f(t) and σ, the response function f(t) can be expressed in a general form expression followed the universal relaxation law that is observed in our experimental observations [8]. f(t) = m t n (7) This expression is inserted into equation (5) and equation (6) and the parameters m and n are fitted in the non-linear least square manner. Uno G fvert explains the steps in detail [7]. III. EXPERIMENTAL SET UP discharging time. 4. Decay voltage was measured with 200 V DC, 200 s charging and 1000 s decay. 5. Measured Polarisation and Depolarisation current with 1000 V DC, 10000 seconds polarisation 10000 seconds depolarisation time. In order to eliminate the previous polarisation effects that might affect the accuracy of the measurements, the shortcircuiting of the two arrester s terminals to the ground for at least 24-hour is necessary before proceeding with step 3,4 and 5. 6. All MO varistors were then systematically degraded as follows: a. D1, D2, S1 and S2 were subjected to 15 single pulse (8/20µs) at 2 p.u., 4 p.u., 2 p.u. and 4 p.u. with intervals of 1 minute plus time to charge the system respectively. b. D3, D4, S3 and S4 were subjected to 5 groups of multipulse current at 3 p.u., 1.5 p.u., 1.5 p.u., and 2 p.u. respectively with small time intervals required to charge the system. The multipulse current test consisted of the application of quintuple (5) 8/20µs lightning current impulses [9]. 7. Repeat steps 1, 2, 3, 4 and 5 (after diagnostic measurement). IV. TEST RESULTS The results from 1 ma reference voltage and residual voltage measurements on the MOSA are presented in Tables 1 and 2 respectively. TABLE I. 1 MA REFERENCE VOLTAGE The 10kA distribution type MOSA used for this study were commercial devices produced by one manufacture. There are two different types: identified as (i) Double block: D1, D2, D3, D4 and (ii) Single Block: S1, S2, S3 and S4. Double block arresters were made of two block varistors and had rated voltage of 12.5 kv. Single block arresters consisted only one block and had rated voltage of 6.3 kv. They were new arresters and had identical characteristics in terms of reference voltage, residual voltage and return voltage, decay voltage and Pol/Depol current for each type of arresters. Experimental procedures are summarised as follows: 1. Reference voltages at 1 ma AC current were measured for all test samples. 2. Residual voltages were measured at rated current (10 ka) of 8/20µs. 3. Performed Return Voltage Measurement on all MOSA varistors with 1000 V DC, 200 s charging time and 100 s The changes in 1 ma reference voltage and residual voltage were within the allowable ± 5% except for arrester D3. Arrester D3 had its residual voltage reduced by 5.56% and its

4 1 ma reference voltage increased by more than 6 % of its original value. The results indicate that arrester D3 failed the standard test according to A.S. 1307.2. while the other arresters passed. TABLE. II. RESIDUAL VOLTAGE conductivity except for arrester S3 that its conductivity slightly increased. Arrester D3 showed the biggest reduction in its slope and the corresponding conductivity. Its conductivity was less than half of it was before subjected to current pulse. TABLE IV. DECAY VOLATGE RESULTS Table III, IV and V present the result of return voltage, decay voltage and Pol/Depol current measurements respectively. TABLE III. RETURN VOLTAGE RESULTS TABLE V. POLARISATION / DEPOLARISATION RESULTS The average initial return voltages and central-time constants are calculated to give reference values for comparison. Table III. presents the average initial values for each arrester types and the after diagnostic results. It shows clearly that both return voltage and central time constant for all arresters decreased after subjected to current impulse. Arrester D3 showed the most significant change. It had its return voltage reduced to 40% of its original value and reached the peak voltage more than three times faster of its initial centraltime constant. Arrester D1 showed the second biggest reduction in its return voltage and central-time constant. Table IV. indicates that the pulsed arresters had less Table V. again shows that the conductivity for all arresters decreased (1.2 % to 30 %) after the current pulse except for arrester S2 that was slightly increased. Arrester D3 had the most significant reduction in its conductivity. It reduced from 2.68E-11 to 1.88E-11 that was about 30% less conductivity than its initial condition. V. DISCUSSIONS The changes in 1 ma reference voltage and residual voltage were within the allowable ± 5% except for the arrester D3. The results indicate that all arrester except D3 passed the A.S 1307.2 diagnostic test. However, there is slight anomaly. It was found that the 1 ma reference voltages for all arrester

5 were increased after subjected to current pulses. These do not make sense, the degraded arrester should have less voltage to force 1 ma current through the arrester. The return voltage results indicates clearly that the insulation condition of MOSA have changed. The reduction of their return voltage and central-time constant may explain the MOSA characteristic after the current pulses. Arrester D3 had the biggest reduction in both return voltage and central-time constant. It had its return voltage decreased more than 61 % of its initial value and reached the peak voltage in shorter time. The changes in conductivity showed on Table. IV and V imply that the V-I characteristics of MOSA have also changed. The reduction in conductivity suggests that the difference between the residual voltage and rated voltage has increased. This will cause the MOSA to operate less effective. Arrester S2 has its conductivity slightly increased while the others have their conductivity reduced. D3 showed the most significant reduction in its conductivity. Table. VI. compares the results from different diagnostics. It suggests clearly that all the diagnostic techniques presented in this paper have shown the same tendency and had a strong correlation. They have agreed that the characteristic of D3 has been severely altered by the exposure to lightning current pulses while the characteristics of other arresters have also been changed in the same manner.. TABLE VI. DIFFERENT DIAGNOSTIC TEST RESULTS results indicate a comparable degree of degradation for each of different techniques. The new techniques show significant changes while a number of existing techniques such as 1 ma reference voltage and residual voltage measurement show less. This indicates that new techniques give more information of the arresters condition. In conclusion, this paper reports on the new diagnostics as well as the existing techniques on the MOSA in laboratory condition. The theory of dielectric responses and the results obtained from this study have proven that the modern electrical diagnostics such as return voltage, decay voltage and Pol/Depol current have shown good indications of the ageing level of MOSA. Further work is needed to conduct measurements on field arresters. Additional aspects concerning the accuracy of the new techniques will be investigated. VII. REFERENCES [1] Surge Arresters Part 2: Metal Oxide Surge Arresters without Gaps for AC Systems. Australian Standard 1307.2. 1996. [2] C. Heinrich and W. Kalkner "Return Voltage Measurement on Metal Oxide Surge Arrester". in 10 th 1nternational Symposium on High Voltage Engineering, Vol.5: pp.137-40 Montreal, Canada. 1997. [3] T.K. Saha and T. Dinh "Return Voltage Measurements on Metal Oxide Surge Arresters". in International Symposium on High Voltage Engineering. London, England. 1999. [4] K.P. Mardira, M.Darveniza, T.K.Saha, Search for New Diagnostics for Metal Oxide Surge Arrester, on The 6 th International Conference on Properties and Applications of Dielectric Materials, pp. 947-50, Xian - China, 21-26 June 2000. [5] E. Nemeth, Measuring Voltage Response: a non-destructive diagnostic test method of high voltage Insulation, Science Measurement and Technology, Vol. 146, No.5, Sept 1999. Pp.249-252. [6] E. Nemeth, T. Hrovath, Fundamental of the Simulation of Dielectric Processes of Insulation, in 8 th International Symposium of High Voltage Engineering, pp. 177-180, Budapest, Hungary 1993. [7] U. G fvert, Condition Assesment of Insulation System- Analysis of Dielectric Response Methods, Nordic Insulation Sysmposium, Bergen Norway, June 1996. [8] A.K. Jonsher, Dielectric Relaxation in Solids, Chelsea Dielectric Press, London 1983. [9] M. Darveniza, et al., A Multiple Lightning Impulse Generator, 6 th Int. Symp on High Voltage Engineering, New Orleans, paper 47.07, Aug/Sep 1989. The above diagnostic results have also given indication that the effect of multipulse lightning current is much more severe than single lightning pulse at higher level. This was evidenced comparing the results of Arrester D2 and D3. Arrester D3 had been subjected to 5 groups of multipulse current at lower current level (3 p.u.) than D2 which was subjected to single lightning current pulse at 4 p.u. VI. CONCLUSIONS VIII. BIOGRAPHIES Karl Primardi Mardira, born in 1976, graduated with a Bachelor of Engineering (Honours) in Electrical Engineering from the University of Queensland in 1998. His research interests are in power system analysis, power system protection and insulation system. Now He is pursuing his Ph.D. studies at the University of Queensland, Australia. Tapan Kumar Saha is Senior Lecturer in the School of Information Technology and Electrical Engineering, The University of Queensland, Australia. He is a Senior Member of the IEEE and a Chartered Professional Engineer of the Institution of Engineers, Australia. His research interests include power systems & condition monitoring of electrical equipment A number of new diagnostic techniques for assessing the condition of MOSA have been discussed in this paper. The