Consensus with ISO EN Overview. Innovative by tradition.

Similar documents
Consensus with ISO EN Overview. Innovative by tradition.

Data Sheet. Functional Safety Characteristic Safety Values for BE..(FS) Brakes * _0715*

Polymer Electric. Product Information. Safety Edges SL/W and SL/BK. GmbH & Co. KG. Polymer Electric

Data Sheet. Functional Safety Characteristic Safety Values for BE.. Brakes * _0715*

Application Guide. TwinSAFE. Version: Date:

Safety Instrumented Systems & Functional safety of safety-related systems. A substantial new opportunity for Pfannenberg Signaling products

Non-Contact Safety Systems CMS

AC axial compact fan


AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

Lamp and Control Panel (Lamp Panel)

AC axial compact fan

Technical Data Sheet.

AC axial compact fan

Q-300 TCT Application Note - A-Q-300TCT-BallGridArrays-001a-EN

AC axial compact fan

PHOENIX CONTACT - 04/2016. Features

Features N channel Logic level Enhancement mode Temperature sensor with thyristor characteristic The drain pin is electrically shorted to the tab 1

VK2 volume flow controller Overview

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

Transparent building elements. Translucent building elements. Environmental Product Declaration (EPD) Short version Declaration Code: EPD-RLE-33.

I D-ISO W Power dissipation P tot

I D-ISO W Power dissipation P tot

Operating Instructions for Digital Manometer. Model: MAN-SD

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Drive Technology \ Drive Automation \ System Integration \ Services. Data Sheet. Functional Safety Safety Characteristics for BE..

OptiMOS -P Small-Signal-Transistor

Drive Technology \ Drive Automation \ System Integration \ Services. Data Sheet. Functional Safety Safety Characteristics for Brake BE..

Actuators with ball monorail guidance system and ball screw drive MKUVE15-KGT, MKUVE20-KGT

HELLA AGLAIA MOBILE VISION GMBH

Software BioScout-Calibrator June 2013

Lufft Ceilometer Series

KM-70 Panel-mounting Thermostat

DIGITAL THERMOMETER OPERATOR S MANUAL

HiPace 300 with TC 400, DN 100 CF-F

Monitoring polymerization

HiPace 300 with TC 110, DN 100 CF-F

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

PRODUCT SPECIFICATIONS

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

TRIANGO 100 Minor Surgery Light Experience quality and ergonomic light

SPXTIN : Sleeve Adapter for Mast

Test methods GRAPHENE- HEAT DISSIPATION SHEET GADIANT. Product Name: Gadiant Purpose: electrical and electronic equipment fever reduction

Surface-mounting thermostats Series ATH

Infrared Hand-Held Thermometers

8 Installation Equipment

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Capacitive Sensors. Contents

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DATA RACK BUSBAR. Data Rack Busbar Systems A.

Product Selector Guide

Impedance Uncertainty Contribution of Artificial Networks (AN, AMN and ISN) Application Note

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Globe Valve, Metal. Sectional drawing. *see information on working medium on page 2

BETA Protecting Miniature Circuit Breakers

Facts and figures MULTILIFT SELECT 15

The first address for Titration. TITRONIC 300 and TitroLine 5000

PRODUCT SPECIFICATIONS

35H MPa Hydraulic Cylinder 3.5 MPa Hydraulic Cylinder 35H-3

ROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled

CERTIFICATE OF ANALYSIS

Mean fault time for estimation of average probability of failure on demand.

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Plant Protection Information Systems for Public use in Slovenia use of meteorological information's. Andrej Hocevar 2

Partial stroke tests as a procedure for the extension of the proof test interval

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

Best color perception in spotlighting and downlighting

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

WCAP-FTXX Film Capacitors

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED

Impulse and Conservation of Momentum

GaAlAs Light Emitting Diode (660 nm) Version 1.3 SFH 464 E7800

P R O D U C T I N F O R M AT I O N. The minitwin safety light curtain. Minivation: the world s smallest light curtain.

Reliability Analysis of Electronic Systems using Markov Models

SIPMOS Small-Signal-Transistor

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics

LED light engine / OLED LED compact. Uready2apply DLA G1 SNC China domestic

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

D a t a s h e e t. T o r q u e s t a n d a r d. S e r i e s D m - T N. ( 1 N m N m ) Benefits/Application. Options/Accessories

CERTIFICATE OF ANALYSIS

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC umodule SLE ESSENCE

SKF actuators available for quick delivery. Selection guide

Chapter 12. Spurious Operation and Spurious Trips

D/A-Converters. Jian-Jia Chen (slides are based on Peter Marwedel) Informatik 12 TU Dortmund Germany

PHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE

HiPace 1200, with TC 1200, DN 200 CF-F

LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC China domestic umodule SLE ESSENCE

Chapter 18 Section 8.5 Fault Trees Analysis (FTA) Don t get caught out on a limb of your fault tree.

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm TINGE R SNC umodule SLE ESSENCE

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Safety analysis and standards Analyse de sécurité et normes Sicherheitsanalyse und Normen

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

High Power Infrared Emitter (940 nm) Version 1.3 SFH Features: High Power Infrared LED Emission angle ± 11 High radiant intensity

Transcription:

Innovative by tradition. Consensus with ISO 13849-1 EN Overview Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY Phone: +49 731 2061-0 Fax: +49 731 2061-222 E-mail: info.ulm@mayser.com Internet:

Type SG-EFS 104/4L SG-EFS 104/2W SG-EFS 1X4 ZK2/1 SG-EFS 1X4 ZK2/1 8k2 Safety according to ISO 13849-1:2015 Category 3 PL e Category 3 PL d Category 3 PL e Category 3 PL e Performance Level e d e e Category 3 3 3 3 level 73 years 1) 257 years 1) 313 years 1) 313 years 1) level medium low medium medium 90 % 60 % 90 % 90 % B 10D [ 10 6 ] 0.4 1.8 2 2 Reaction time < 30 ms < 15 ms < 10 ms < 10 ms Type SG-SLE X4-0X1 SG-RST 204 SG-RST 153 SG-RS 204 Safety according to ISO 13849-1:2015 Category 3 PL e Category 3 PL e Category 3 PL c Category 3 PL c Performance Level e e c c Category 3 3 2 1 level 279 years 1) 306 years 1) 33 years 1) 155 years 1) level medium medium medium medium 90 % 90 % 90 % B 10D [ 10 6 ] 2 2 0.18 1 Reaction time < 14 ms < 20 ms < 5 ms < 15 ms 1) assumed parameters : d op = 365 d/a, h op = 24 h/d, t cycle = 600 s (n op = 52560/a) 2) Suitable for installation of Category 3 systems up to PL d. 3) level and value are dependent on the particular application (see page 4). 4) dependent on profile 2/6 Consensus with ISO 13849-1

Safety mats SM Safety mats SM11 Safety mats SM8 Safety steps TS Safety edges SL 1 2) 1 2) 1 2) 1 2) 1 2) 6 6 6 6 4 8 ms 8 ms 8 ms 8 ms 4) Safety edges SL NO NC safety edges SL NC II Sensor profiles SP Miniature safety edges EKS Safety bumper SB 1 2) 1 2) 1 2) 1 2) 1 2) 4 2 2 2 2 4) 4) 4) 4) 4) 1) assumed parameters : d op = 365 d/a, h op = 24 h/d, t cycle = 600 s (n op = 52560/a) 2) Suitable for installation of Category 3 systems up to PL d. 3) level and value are dependent on the particular application (see page 4). 4) dependent on profile Consensus with ISO 13849-1 3/6

Determining the PL r For each selected safety function it is first necessary to determine the required performance level (PL r ) and to compare it with the performance level (PL) achieved by the Mayser sensor. The PL r of the safety function must correspond at least to the PL. Determining the sensor = B 10D 0.1 n op Example 1: Safety mat in front of processing centre with 30-second cycle in 3-shift operation, 250 days per year. n op = 120 actuations/h x 24 h/day x 250 days = 720,000 actuations per year = B 10D / (0.1 x n op ) = 6,000,000 / (0.1 x 720,000) = 83.3 years => Example 2: NC safety edge on sliding gate with 2 actuations per day (morning and evening), 365 days per year. n op = 2 actuations/day x 365 days = 730 actuations per year = B 10D / (0.1 x n op ) = 2,000,000 / (0.1 x 730) = 27,397.3 years => Determining the overall 1 1 1 = + SG sensor Example 3: As in example 1; Safety mat SM connected to SG-EFS 1X4 ZK2/1. SG = 313 years SM = 83 years 1 1 1 = + 313 years 83 years = 65 years => 4/6 Consensus with ISO 13849-1

The same example with exclusion of error according to ISO 13849-2 Table D.8: Non-closing of contacts in the case of pressure-sensitive equipment according to ISO 13856. In this case the value of the sensor is no longer taken into account for the overall system. 1 1 = SG Example 4: As in example 3; Safety mat SM connected to SG EFS 1X4 ZK2/1. SG = 313 years 1 1 = 313 years = 313 years => In this case, the maximum performance level of the overall system can reach PL d. table Designation Zone low medium 3 years < < 10 years 10 years < 30 years 30 years < 100 years table Designation Zone none < 60 % low 60 % < 90 % medium 90 % < 99 % 99 % Consensus with ISO 13849-1 5/6

Determining the PL If the categories, and are known, the performance level (PL) can be determined based on the table. The table shows a simplified procedure for assessment and is used in the first step for estimating the PL. Example 5: SG-EFS 104/2W Category 3 = 60 % = 257 years Result: => low => => PL d Simplified process for determining the achieved PL Category B 1 2 2 3 3 4 none none low medium low medium low medium a a b b c b b c c d c c d d d e PL => SIL Note: Safety edges, safety mats or safety bumpers can reach a maximum PL d, with exclusion of error Performance Level (ISO13849) Safety Integrity Level (IEC 61508) Probability of a dangerous failure (PFH) [1/h] PL a 10-4 > X 10-5 PL b SIL 1 10-5 > X 3x 10-6 PL c SIL 1 3x 10-6 > X 10-6 PL d SIL 2 10-6 > X 10-7 PL e SIL 3 10-7 > X 10-8 6/6 Consensus with ISO 13849-1