Exchangeable Thermoblock for slides DC Operating instructions

Similar documents
Thermomixer compact / Thermomixer. Operating Manual /1008

Applications Note 164 October 2007

Eppendorf SmartBlock. Instructions for use

NEW. A class of its own. Centrifuge 5430 / 5430 R

N) manual. Biomaster Operating manual

Applications Note 202 October 2008

96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing

Applications Note 215 September 2009

Now also in Eppendorf LoBind. Conical Competence. Eppendorf Conical Tubes 15 ml and 50 ml

NEW! ep Dualfilter T.I.P.S. Peak of perfection

The Plus for your lab!

Eppendorf Reference : The pipette.

Eppendorf Plate Deepwell 96 and 384: RecoverMax

N) justment. Register your instrument! Eppendorf Research plus. Factory Adjustment

NEW: 5.0 ml screw cap tube. The Missing Link. Eppendorf Tubes 5.0 ml Discover a new sample handling system

Eppendorf Vis Cuvettes. Instructions for use

NEW! Your bacteria s favorite! Eppendorf Eporator

Raise the limits. Eppendorf Research plus

stance et Helper Eppendorf Pipet Helper Chemical Resistance

Technical Report Eppendorf Deepwell Plates and Microplates Investigations of sealing methods

Technical Report Exact dispensing of whole blood using the Eppendorf positive displacement system Multipette Xstream /Repeater Xstream

Applications Note 228 September 2010

Eppendorf UVette. Instructions for use

Electrical safety testing Checklist

December 2010 No 036. The electronic Eppendorf Xplorer pipette Versatile adjustment

ept.i.p.s. Version A

No 022 December Application-Specific Requirements for Consumables in the Laboratory

NGS Made Easy. Optimize your NGS library preparation with the epmotion Automated liquid handling system

Multiple Talents. Eppendorf Temperature Control and Mixing Instruments

Simply Better Pipetting

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

INSTALLING TRAK SPORT TIRE CHAINS ON 20 MODEL 3 TIRES

Cleaning and Decontamination of the ept.i.p.s. Box

PhysioCare Concept improved. The feeling of a new philosophy

PhysioCare Concept improved. The feeling of a new philosophy

Keysight Technologies Oxygen-Free High-Resolution Electrochemical SPM. Application Note

NOTE: Performing this procedure invalidates the factory calibration!!

Eppendorf BioSpectrometer 6135/6136/6137

ept.i.p.s. pipette tips are available with various degrees of purity, with and without filters, and as special tips.

The Pure Truth. Eppendorf Forensic DNA Grade according to ISO 18385

Operating Instructions for Digital Manometer. Model: MAN-SD

ab83360 Ammonia Assay Kit

Installation guide 862 MIT / MIR

Eppendorf Temperature Verification System. Operating manual /0909

AN2970 Application note

The Value of Mixing. Eppendorf Temperature Control and Mixing Instruments

ab83360 Ammonia Assay Kit

Well within Reach. The Eppendorf Pipette Holder System

Eppendorf Consumables it s Your sample. Peak of Perfection. Eppendorf Liquid Handling Consumables

E Service E-Series Padlock seires PadlockManual No. Part No. Part No. Part

ept.i.p.s. Instructions for use Version B

ab MDA Assay Kit (competitive ELISA)

STTH16R04CT. Ultrafast recovery diode. Main product characteristics. Features and benefits. Description. Order codes TO-220AB TO-220FPAB

BSH Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor

Surface-mounting thermostats Series ATH

LD29300xx. 3 A, very low drop voltage regulators. Features. Description

Superior well-to-well Consistency with Eppendorf Cell Culture Plates

Order codes Part numbers DPAK (tape and reel) PPAK (tape and reel)

LEAPERS, INC. RED/GREEN DOTS

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

1 Product description. Material. 3 Warnings for intended use. Instructions for use ept.i.p.s. Version B. English (EN)

The Next Stage. The new Mastercycler X50

NEW! PCR next to me. Eppendorf Mastercycler nexus: combine, connect, control

PLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or

Keysight Technologies Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation. Application Note

Eclipse Refractometer General Models

L78LxxAB L78LxxAC - L78LxxC

Requirements to perform accurate dielectric material analysis

FOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL

Keysight Technologies Instrumented Indentation Testing with the Keysight Nano Indenter G200. Application Note

Ballistic pendulum Operating Instructions Fig. 1: Ballistic pendulum SAFETY PRECAUTIONS

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

STTH60R04. Ultrafast recovery diode. Main product characteristics. Features and benefits. Description. Order codes

Lamp and Control Panel (Lamp Panel)

3B SCIENTIFIC PHYSICS

Spa & Wellness for Pipettes

Fast, Effective XPS Point Analysis of Metal Components

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½

ab Universal HIER antigen retrieval reagent (10X)

Surface Zeta Potential Cell (ZEN1020)

KD A LOW DROP POSITIVE VOLTAGE REGULATOR ADJUSTABLE AND FIXED

WEATHER STATION FIELD GUIDE

TEMPERATURE COMPENSATION FOR MEAS PRESSURE SENSORS APPLICATION NOTE

HD74HC42. BCD-to-Decimal Decoder. ADE (Z) 1st. Edition Sep Description. Features

Facts and figures MULTILIFT SELECT 15

MC ILLUMINATED USER MANUAL

DO-15 DO-201AD STTH3R04Q STTH3R04

PRODUCT SPECIFICATIONS

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Protein Carbonyl Content Assay Kit

PHOENIX CONTACT - 04/2016. Features

of mass spectrometry

TECHNICAL INFORMATION

7.5A LOW DROP POSITIVE VOLTAGE REGULATOR ADJUSTABLE AND FIXED. October 2002

The New Eppendorf X-Drive - Maximum Performance, Flexibility and Longevity for Demanding Shaker Tasks

VK2 volume flow controller Overview

Optimization of temperature-sensitive assays using the Spark Te-Cool

Transcription:

Exchangeable Thermoblock for slides DC Operating instructions

Table of contents 1 General.................................................. 3 2 Safety instructions......................................... 3 3 Mounting................................................. 4 4 Application............................................... 7 5 Cleaning / Service.......................................... 8 5.1 Replacing the snap seal...................................... 8 5.2 Replacing the lid............................................ 9 6 Technical data............................................ 10 7 Ordering information...................................... 11 No part of this publication may be reproduced without the prior permission of the copyright owner. Copyright 2005 Eppendorf AG, Hamburg 2

1 General / 2 Safety instructions 1 General Only experienced laboratory personnel are permitted to use the slides thermoblock. The exchangeable Thermoblock for slides DC is especially designed for processing either DNA or protein microarrays using the Eppendorf hybridization frames in research laboratories in the fields of bioscience, medicine and chemistry. The Thermoblock for slides DC can be used on both the Thermomixer comfort or the ThermoStat plus. It can be used for rotational movement up to a maximum of 1,400 rpm and at a maximum temperature of 70 C. 2 Safety instructions When exchanging a heated block, please keep in mind that contact with the surface of the opened exchangeable thermoblock, its underside or the thermal base on the basic device can result in burns! Exchange the thermoblock once it has cooled down. Make certain that the slides are inserted precisely into the recesses. The Thermoblock for slides DC is compatible with slides with a maximum length of 76.70 mm. Make sure that the block is clean (no glass particles) before placing slides. Make sure that the pressure plate is correctly fixed. See mounting part of this manual. The lid of the Thermoblock for slides DC must be tightly closed (lid parallel to block) prior to using the mix function. Be sure to observe the maximum rotational speed of 1,400 rpm and the maximum temperature setting of 70 C. The ThermoStat plus basic device has no block recognition function. There is no automatic limitation of the temperature control. Do not use damaged thermoblocks. Exchangeable thermoblocks may only be used in conjunction with the ThermoStat plus and Thermomixer comfort devices. See their respective operating manuals for more information. This operating manual must also be handed over if you give the slides thermoblock to someone else. 3

3 Mounting 1. To mount the exchangeable Thermoblock for slides DC, open the lid by simultaneously pressing the two pressure points on the front edge of the lid. The pressure points are labeled with "push". Figure 1: Drawing of the Thermoblock for slides DC 3 1 Pressure plate 2 Screws 3 Lid seal 4 Label 2 1 4 2. Alternately unscrew the 2 screws of the pressure plate until the pressure is completely released (Figure 1). 3. Adjust the exchangeable Thermoblock for slides DC on the basic device in such a way that the label can be seen from the front. Screw it tight using a Hexagon key. 4

3 Mounting 4. Place the slides (up to 4) in the Thermoblock for slides DC. The slides have to be inserted with the sticker facing the front part of the thermoblock (Figure 2). Figure 2: Drawing of the opened Thermoblock for slides DC 1 Slide 2 Pressure plate location ridges 3 Holes to remove the slide 4 Front part of the thermoblock 2 1 3 4 2 5

3 Mounting 5. Position the pressure plate on top of the Thermoblock for slides DC and push it firmly into the location ridges. Hold both plate and thermoblock tightly and alternately fasten both screws completely using the screwing tool (Figure 3). Screwing tool Pressure plate location ridge Pressure plate Pressure plate location ridge Thermoblock for slides DC assembly Figure 3: Schematic drawing of the Thermoblock for slides DC assembly and the screwing tool. 6

3 Mounting / 4 Application 6. Close the lid and push down the 2 pressure points on the front edges of the lid. It is absolutely necessary to ascertain that the lid has been correctly closed prior to starting the device. In the case of the Thermomixer comfort, block identification occurs after the exchangeable Thermoblock for slides DC has been correctly positioned. This results in an automatic limitation of maximum possible rotational speed (1400 rpm) and temperature setting (70 C). In the case of the ThermoStat plus there is no block identification function for technical reasons. Please set for max. temperature of 70 C. 7. After the incubation step, open the Thermoblock for slides DC lid and unscrew the pressure plate (caution: hot plate) by alternating between both screws. 4 Application An Eppendorf hybridization frame must be positioned above the microarray on the slide surface in order to carry out the reaction. In the case of using DualChip microarrays from Eppendorf, hybridization frames are already placed on the slides. Four slide positions are provided on the exchangeable Thermoblock for slides DC. 7

5 Cleaning / Service To clean the Thermoblock for slides DC, switch off the power supply and unplug the device. Ascertain that the surface of the opened Thermoblock for slides DC and its underside as well as the thermal base on the basic device have cooled down completely to minimize the risk of burns. Unscrew the block from the basic device. Clean the exchangeable Thermoblock for slides DC immediately if sample liquid finds its way into the bores. A mild soap solution or lab cleaner can be used for cleaning. The device should be protected from organic solutions and aggressive chemicals. For disinfection purposes, please use alcohol-based infectants. The sealant material in the lid can be removed and cleaned or replaced. 5.1 Replacing the snap seal If sample liquid finds its way into the two snap seals of the block, remove them from the block and wash them separately in a soap solution or in an ultrasonic bath or replace them. The removal of the locking devices from the exchangeable Thermoblock for slides DC is carried out by pressing both of the side catches beneath the block together and simultaneously pressing them out of the block (see Figure 4). Be aware of the direction when reinserting the locking systems into the block: the directional marking on the right side must point forward while that on the left side points to the rear. Figure 4: Changing the snap seal 1. Press the side catches together simultaneously 2. Push out the lock 3 Directional marking 2. 3 8 1.

5 Cleaning / Service 5.2 Replacing the lid The lid, including the seal, can also be replaced when damaged: To do this, loosen and remove the 2 slotted head screws at the side of the lid with a slotted head screwdriver (N 2). Replace the lid and refasten it by retightening the 2 slotted head screws (Figure 5). Figure 5: Replacing the lid 9

6 Technical data Slide positions: Slide dimensions: Rotational speed: Temperature control: Temperature homogeneity: max. of 4 positions Length 74.5 76.7 mm Width 24.7 26.3 mm Height 0.9 1.2 mm max. 1400 rpm to a maximum of 70 C possible T max T min 2 K * (at 70 C) T max T min 0,5 K * (at 45 C) Heating-up speed of the thermoblock: > 5 K / min * Chemical resistance: The use of strong acids, bases or acetone is not recommended. This could result in damage to the surface. Cooling-off period from 70 C to 10 K above the ambient temperature: 20 min * Data determined with a Thermomixer comfort. 10

7 Ordering information Product Description Order no. for North America Order no. International Thermoblock for slides DC 022670786 5368 000.100 Lid with seal Snap seal Products Thermomixer comfort / R 115 V 220 V ThermosStat plus (without block) Silverquant adapter 0022670727 0022670743 022670107 022670158 022670204 956015073 5368 851.002 5368 852.009 5355 000.011 5352 000.010 5368 000.037 11

12

EG-Konformitätserklärung EC Conformity Declaration Das bezeichnete Produkt entspricht den einschlägigen grundlegenden Anforderungen der aufgeführten EG-Richtlinien und Normen. Bei einer nicht mit uns abgestimmten Änderung des Produktes oder einer nicht bestimmungsgemäßen Anwendung verliert diese Erklärung ihre Gültigkeit. The product named below fulfills the relevant fundamental requirements of the EC directives and standards listed. In the case of unauthorized modifications to the product or an unintended use this declaration becomes invalid. Produktbezeichnung, Product name: Wechselblock für slides DC / Exchangeable Thermoblock for slides DC Produkttyp, Product type: Thermoblock / Thermoblock Einschlägige EG-Richtlinien/Normen, Relevant EC directives/standards: 98/79/EG, EN 14971 Vorstand, Board of Management: 14.07.2005 Projektmanagement, Project Management: Hamburg, Date: Eppendorf AG Barkhausenweg 1 22339 Hamburg Germany 0015 033.509-02 5368 900.240-00

Eppendorf Offices ASEAN Eppendorf AG Regional Office in Malaysia Tel. +60 3 8023 2769 Fax +60 3 8023 3720 E-Mail: eppendorf@eppendorf.com.my Internet: www.eppendorf.com.my AUSTRALIA / NEW ZEALAND Eppendorf South Pacific Pty. Ltd. Tel. +61 2 9889 5000 Fax +61 2 9889 5111 E-mail: Info@eppendorf.com.au Internet: www.eppendorf.com.au AUSTRIA Eppendorf AG c/o Schott Austria Tel. +43 1 29017560 Fax +43 1 290175620 E-Mail: gilch.p@eppendorf.de Internet: www.eppendorf.com BRAZIL Eppendorf do Brasil Ltda. Tel. +55 11 30 95 93 44 Fax +55 11 30 95 93 40 E-Mail: eppendorf@eppendorf.com.br Internet: www.eppendorf.com.br CANADA Brinkmann Instruments, Ltd. Tel. +1 905 826 5525 Fax +1 905 826 5424 E-Mail: canada@brinkmann.com Internet: www.brinkmann.com CHINA Eppendorf AG Tel. +86 21 68760880 Fax +86 21 50815371 E-Mail: market.info@eppendorf.cn Internet: www.eppendorf.cn FRANCE EPPENDORF FRANCE S.A.R.L. Tel. +33 1 30 15 67 40 Fax +33 1 30 15 67 45 E-Mail: eppendorf@eppendorf.fr Internet: www.eppendorf.fr GERMANY Eppendorf Vertrieb Deutschland GmbH Tel. +49 02232 418-0 Fax +49 02232 418-155 E-Mail: vertrieb@eppendorf.de Internet: www.eppendorf.de INDIA Eppendorf India Limited Tel. +91 44 52111314 Fax +91 44 52187405 E-Mail: info@eppendorf.co.in Internet: www.eppendorf.co.in ITALY Eppendorf s.r.l. Tel. +390 2 55 404 1 Fax +390 2 58 013 438 E-Mail: eppendorf@eppendorf.it Internet: www.eppendorf.it

Eppendorf Offices JAPAN Eppendorf Japan Co. Ltd. Tel. +81 3 5825 2363 Fax +81 3 5825 2365 E-Mail: info@eppendorf.jp Internet: www.eppendorf.jp USA Eppendorf North America Tel. +1 516 334 7500 Fax +1 516 334 7506 E-Mail: info@eppendorf.com Internet: www.eppendorfna.com NORDIC Eppendorf Nordic Aps Tel. +45 70 22 2970 Fax +45 45 76 7370 E-Mail: nordic@eppendorf.dk Internet: www.eppendorf.dk SPAIN Eppendorf Ibérica S.L. Tel. +34 91 651 76 94 Fax +34 91 651 81 44 E-Mail: iberica@eppendorf.de Internet: www.eppendorf.es OTHER COUNTRIES see: www.eppendorf.com/worldwide SWITZERLAND Vaudaux-Eppendorf AG Tel. +41 61 482 1414 Fax +41 61 482 1419 E-Mail: vaudaux@vaudaux.ch Internet: www.eppendorf.com UNITED KINGDOM Eppendorf UK Limited Tel. +44 1223 200 440 Fax +44 1223 200 441 E-Mail: sales@eppendorf.co.uk Internet: www.eppendorf.co.uk

In touch with life eppendorf is a registered trademark. B 5368 900.100-01/0805 Printed in Germany Your local distributor: www.eppendorf.com/worldwide Eppendorf AG 22331 Hamburg Germany Tel. +49 40 5 38 01-0 Fax +49 40 5 38 01-556 E-Mail: eppendorf@eppendorf.com Eppendorf North America, Inc. One Cantiague Road, P.O. Box 1019 Westbury, N.Y. 11590-0207 USA Tel. +1 516 3 34 75 00 Free phone +1 800 6 45 30 50 Fax +1 516 3 34 75 06 E-Mail: info@eppendorf.com Application Support Europe, International: Tel. +49 180 3 66 67 89 E-Mail: support@eppendorf.com North America: Tel. +1 800 6 45 30 50 ext. 2258 E-Mail: support_na@eppendorf.com Asia, Pacific: Tel. +60 3 80 23 27 69 E-Mail: support_asia@eppendorf.com