Pre-certification PVC and Rilrld Aluminum Conduit Expansion

Similar documents
19.3 Design of Feeders for Industrial Power Systems

Conductor sizing is a critical step

Unit 11 Wire Tables and Conductor Sizes

Back to Basics: Realizing Cabling Determines Design. F. Patrick Mahoney, CSI CDT, RCDD Direct Supply - Aptura

Coefficient of Friction Measurement On Polywater s Friction Table

Fact-Finding Report on Ambient Temperature Adjustment for Raceway and Cable Systems Exposed to Sunlight on Rooftops

Measurement. Scientific Notation. Measurements and Problem Solving. Writing Numbers in Scientific Notation

Chapter 3, Lesson 1: What is Density?

3M Twisted Pair, Flat Cable,.050" 28 AWG Stranded, Halogen Free Polyolefin, 2100/20TP, 30m

RIGID PVC CONDUIT FITTINGS AND ACCESSORIES

Introductory Chemistry: A Foundation, 6 th Ed. Introductory Chemistry, 6 th Ed. Basic Chemistry, 6 th Ed.

東莞永力電業有限公司 YUNG LI CO., LTD REVISION RECORD YUNG LI. Customer : Parts No. : Draw No. : CY-U0003 TC02CCCCYY-95 CUSTOMER APPROVED

Chapter 3, Lesson 1: What is Density?

Example 3: 4000: 1 significant digit Example 4: : 4 significant digits

Series Shrink Boot Adapters. Series Shrink Boot, EMI/RFI, Strain Relief. Series Shrink Boot, EMI/RFI, Shield Sock

EE301 RESISTANCE AND OHM S LAW

File E28476 Vol. 7 Sec. 44 Page 1 Issued: Vol. 23 Sec. 18 Revised: Vol. 67 Sec. 4 and Report D E S C R I P T I O N

Notes Chapter 2: Measurements and Calculations. It is used to easily and simply write very large numbers, and very small numbers.

PCB-RULER-ND: Metric Side Rev 1 (March 2016) 12 inch (~30.5cm)

LEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes

ELECTRICAL THEORY ESSENTIAL FOR JOURNEYMAN AND MASTER/CONTRACTOR LICENSING EXAMS CHAPTER

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP

How is an object s density related to its volume, mass, and tendency to sink or float? Materials

TEMPERATURE SENSOR. Model TH-T. Roctest Limited, All rights reserved.

CONDUCTORS, INSULATORS, AND ELECTRON FLOW

AREA. The Square Inch The Square Foot The Square Yard. 1 foot. 1 foot. The Square Mile The Square Meter The Square Centimeter. 1 meter.

BOLT SIZE Rec.Torque Ft/Lbs. Max Torque Ft/Lbs

Temperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company

Installation Manual. Models 4911A/4911. VW Rebar Strain Meters

DISTRIBUTION CONDUCTOR STRINGING EQUIPMENT & TECHNIQUES

3 Organizing Data. What is scientific notation? How are precision and accuracy different? How do scientists use graphs to show data?

= e = e 3 = = 4.98%

AP Physics 1 Summer Assignment

Section Volume, Mass, and Temperature

Politecnico di Torino THERMAL ANALYSIS OF POWER LINES: METHODOLOGIES AND APPLICATIONS

CE 320 Structures Laboratory 1 Flexure Fall 2006

Problem Out of Score Problem Out of Score Total 45

Lecture 13 Flow Measurement in Pipes. I. Introduction

Scientific Notation. Sig. Figs. Estimation Density. Unit cancelation

THREE HOLE SPLICE CLEVIS FOR B52 Standard finishes: ZN, GRN Wt./C 126 Lbs. (57.1 kg)

CHM Accuracy, Precision, and Significant Figures (r14) C. Taylor 1/10

Three Core XLPE/LSF/SWA/LSF Power Cable

Chapter 3 Metric Units and Conversions

What You Need to Get Started INSTALLATION GUIDE

Unit 1 - INTRODUCTION MEDICAL MATH Listening guide

Assembly and Operation Manual. April 2016

Chapter 2 Dimensional Analysis

Scientific Notation. Part A: Express each of the following in standard form x x x

Part 2. Sensor and Transducer Instrument Selection Criteria (3 Hour)

CHAPTER 2 Data Analysis

THF / 1SCC330001M THF 1S1 C

Destination Math California Intervention

αα Measuring Global Temperatures 2.1 Measuring Global Temperatures Introductory Chemistry Fourth Edition Nivaldo J.

Basic Math Study Guide. MTI Learning Center Mitchell Training, Inc.

Installation Instructions: ICON Anti-Condensate Controller

Chemistry Basic Science Concepts. Observations: are recorded using the senses. Examples: the paper is white; the air is cold; the drink is sweet.

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

PHYS 212 Final Exam (Old Material) Solutions - Practice Test

Dimensional Analysis

Blocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers

AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L

CONDUCTOR SIZE 20 AWG PG. 12 AWG OF COND. 22 AWG 24 AWG PG L 2881T L 2877T

REVIEW PACKET FOR CHEM 110 EXAM 1

CLASSix UTP Patch Cords

3RD GRADE COMMON CORE VOCABULARY A-L

A R E S O N A N T D U M M Y L O A D

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

KINECTRICS NORTH AMERICA INC. TEST REPORT FOR 774-KCMIL 3M TM COMPOSITE CONDUCTOR

DESCRIBING MATTER. Matter is anything that has mass and volume

Thermal Properties Flammability: Self extinguishing UL94V-0 Maintains dimensional stability under heat:.65 C i.e..150 F as per DIN standard #53458.

Electric Circuits Part 2: Kirchhoff s Rules

10/14/2018. Current. Current. QuickCheck 30.3

Composite Conductor Field Trial Summary Report: Western Area Power Administration FARGO

Composite Conductor Field Trial Summary Report: Western Area Power Administration Phoenix

Lecture Outline Chapter 21. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

Capacitors. HPP Activity 68v1. Charge Inside the Body A Close Look at Cell Membranes

Lecture Presentation. Chapter 1. Introduction: Matter and Measurement. James F. Kirby Quinnipiac University Hamden, CT

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

The influence of thermal properties on power transmission characteristics of HVDC cables a factor analysis

MEASUREMENT IN THE LABORATORY

Current. Lecture 10. Chapter Physics II. Course website:

6 th Grade Math. Full Curriculum Book. Sample file. A+ Interactive Math (by A+ TutorSoft, Inc.)

Fire Resistant Armoured Power Cable

Chemistry Section Review 2.2

Unit 3.4 Dimensional Analysis

16 Appendix 16 Electrical Research Association Report

Engineering Mechanics Department of Mechanical Engineering Dr. G. Saravana Kumar Indian Institute of Technology, Guwahati

[HUTTON CONSUMABLES CATALOG] Hutton Communications, Inc. Jeff Fitzpatrick

RELEASED. Student Booklet. Math III. Fall 2014 NC Final Exam. Released Items

MOFLEX. Insulated copper flexibars

Measurement. 2. The magnitude of the quantity. Even with the same instrument, every order of magnitude jump will generate one more significant digit.

Module 8: Conversions. Instructor Guide

1040 SLIDING MALL FRONT

Stochastic Modelling

In this unit, we will examine the movement of electrons, which we call CURRENT ELECTRICITY.

Thermal-Magnetic Circuit Breaker 2210-T2...

Co Curricular Data Analysis Review

Radiological Control Technician Training Fundamental Academic Training Study Guide Phase I

Transcription:

6 PVC and Rilrld Aluminum Conduit Expansion Rules 12-1100 to 12-1122 govern the use of PVC conduit for electrical installations. t should be noted that in rule 12-1102 it specifies that PVC conduit shall not be used in hazardous locations, or where enclosed in thermal insulation. This rule also specifies the use ofpvc in buildings of non-combustible construction. PVC is not to be used where the temperature exceeds 75 degrees C. Rule 12-1114 specifies the maximum distance between supports for PVC conduit as well as two or more PVC conduits run parallel to each other using a common strap. Rule 12-1118 states that expansion joints are required if the amount of expansion exceeds 45mm, unless the conduit is embedded in concrete. Another iniportant note is that a separate bonding conductor needs to be installed in every run ofpvc to ensure electrical continuity for the bond. Rule 12-1012 should be consulted when dealing with the expansion of other types of conduit such as rigid aluminum conduit. This rule will send you to an expansion calculation chart in appendix B. This expansion chart will provide the proper expansion co-efficient for each major type of conduit. An example calculation is given below the chart to demonstrate how the calculation is to be done. Remember this for the C ofq exam! t is rule 12-1118 and appendix B that must be consulted to calculate PVC expansion. Appendix B specifies the coefficients for conduits used to calculate linear expansion, and it also gives the formula to use to calculate the amount of expansion. Therefore it is not necessary to memorize this formula but it is important to understand how to use it correctly. How to determine the amount of expansion in conduit. First- Calculate the temperature differential in degrees C Second- From appendix B apply the coefficient of expansion for the appropriate conduit Third- Apply the length of conduit run in meters Fourth- Calculate the amount of expansion in mm using the formula: LENGTH OF RUN N METERS X TEMPERATURE DFFERENTAL N DEGREES C X COEFFCENT = AMOUNT OF EXPANSON N mm How to determine the length of run 'before an expansion joint is required using PVC conduit. First- Apply the maximum amount of expansion from rule 12-1118 (45mm) Second- Calculate the temperature differential Third- apply the coefficient of expansion for PVC (.0520) from appendix B Fourth- Calculate the length of run in meters before an expansion joint is required using the formula: AMOUNT OF EXPANSON ALLOWED(45mm for PVC) TEMPERATURE DFFERENTAL X COEFFCENT = Length of conduit permitted without an expansion coupling

7 PVC Conduit Expansion Practice Questions for PVC and Rigid Aluminum Conduit Expansion: 1. Calculate the length of expansion of a 20M run of PVC conduit in a location where the minimum temperature is expected to be -23 C and the maximum temperature is expected to be +30 C? 2. A 25M run ofpvc needs to be installed in a location where the temperature range is expected to be from -45 C to + 30 C. How much will the run of conduit expand in mm? 3. On the roof of a factory, a 22M run ofpvc conduit is about to be installed. The min. temp. is -20 C and the max. temp. is +40 C. How many expansion joints (if any) are required? 4. What is the maximum length between expansion joints for a run ofpvc in an area where the temperature differential is 68 C? 5. What is the maximum distance between expansion joints for a run ofpvc where the min. temp. is -25 C and the max. temp. is + 35 C? 6. f a run ofpvc is to be installed in a location where the temperature ranges from -15 C to +29 C, what is the maxit;num distance between two junction boxes that the conduit can be without the use of an expansion joint? 7. What is the length of expansion of a 12M run ofpvc in an area where the temp. ranges from -45 C to +45 C? 8. What is the calculated amount of expansion for a 31 meter run of Rigid Aluminum conduit installed in an area where the minimum winter temperature is -30 C and the maximum summer temperature is + 35 C? 9. How much will a 19 meter run of rigid aluminum conduit expand in an environment where the minimum temperature is -20 C and the maximum temperature is + 30 C? 10. What amount of expansion will a run of rigid steel conduit have if the minimum temperature is -40 C and the maximum temperature is +40 C?

9 Conduit and Tubin!! Fill t is also important to remember that when the insulation designation is not given in the code book, rule 121014 tells us to calculate based on field measurement. Another important note is to use Table D5 for the area of bare conductors (keep in mind the different types of stranding configurations). Don't forget that derating of the ampacity of the conductors installed in the raceway must still be taken into consideration using TABLE 5C. Practice Questions: Calculate the correct size of conduits for the following conductors. 1. 4- #8 TW-75 3- #1/0 T-90 nylon 4- #4 TWU-75 2. 8-250 kcmil RW90XLPE(600V)jacketed 2-4/0TW-75 3- #12 T-90 nylon 3. 7- #3 TWU-75 10- #14 T-90 nylon 11- # 1 TW-75 4. 3- #2 RW90XLPE(1000V)unjacketed 3- #2 T -90 nylon 4- #2 TWU-75 5- # 10 bare bonding conductor 5. 3- #1/0 RWU-90XLPE 12- #3/0 RW90XLPE(1000V)unjacketed 13- #12 T-90 nylon 14- #6 TW-75 6. 23- #14 TW-75 14- #12 T-90 nylon 15- #12 RW90XLPE(600V)jacketed 10- #6 TWU-75 1- #10 bare solid bond conductor 7. What is the maximum number of#14 T-90 allowed in a 41mm conduit? 8. What is the maximum number of # 2 T -90 allowed in a 103 mm conduit? 9. How many #10 RW-90 XLPE 600V, no jacket conductors are permitted in a 21mm raceway? 10. How many # 12 TW -7 5 aluminum conductors are allowed in a 27mm raceway?

1 0 Maximum Number of Conductors in a Box Rule 12-3034 governs the maximum number of conductors in a box. Subrule 1 explains how to determine which conductors count and on what conditions. Subrule 2 explains the use of table 23 and if any additional hardware or wire connectors need to be accounted for in the reduction of the max. number of conductors allowed in the box. Subrule 3 basically explains the procedure to use when a device such as a GFC is installed in a box. Subrule 4 specifies on the procedure to use when Table 23 cannot be used ( when different sizes of conduct0rs are in one box, or if the box size is not listed on table 23) t explains the use of Table 22 the amount of usable space per insulated conductor. Example one: Calculate the maximum allowable number of#14 conductors allowed in a 4 11/16" X 2 1/8" square box that requires 7 marrettes to be used? Answer: From Table 23,28 #14 conductors are allowed in a 4 11/16" X 2 1/8" box. We must reduce that number by 3 due to the use of the 7 marrettes. Therefore the correct answer would be 25 #14 A WG conductors would be the max. number of conductors allowed in that box. Before an example is given for the use of Table 22, it is important that we realize that one milliliter is the same as one cubic centimeter. t is also important that we realize that even-though metric is predominantly used in the code book, a fmal conversion from cubic centimeters to cubic inches may be necessary as trade sizes of boxes have remained in cubic inches. Example Two: Calculate the size of box required for the following: 4- #14 T-90 nylon 5- #12 R-90 6- #10 T-90 nylon 7- #8 T-90 nylon Answer: From Table 22 4- #14 T-90 nylon = 4 X 24.6 = 98.4 cubic centimeters 5- #12 R-90 = 5 X 28.7 = 143.5 cubic centimeters 6- #10 T-90 nylon = 6 X 36.9 = 221.4 cubic centimeters 7 - #8 T -90 nylon = 7 X 45.1 = 315.7 cubic centimeters total 779 cubic centimeters Convert 779 cubic centimeters to cubic inches (use conversion chart in code book) = 779 X 0.061 = 47.5 cubic inches Therefore a 4" x 4" x 4" = 64 cubic inches

Maximum Number of Conductors in a Box Practice Questions: Calculate the proper trade size of box for the following conductor combinations: 1. 3- #14 T-90 nylon 6- #12 T-90 nylon 7- #12 TW-75 8- #8 RW-90XLPE 2. 16- #14 TW-75 14- #12 T-90 nylon 15- #10 RW-90 16- #8 T -90 nylon 3. 3-14/3 NMD-90 6-14/4 AC-90 7- #14 T-90 8- #6 T-90 4. 45- #12 T-90 nylon 34- #10 RW-90 35- #14 T-90 nylon 12- #6 RW-90 5. How many # 14 T-90 nylon conductors are allowed in a box trade size of 6" X 6" X 6"? 6. What is the maximum number of # 10 A WG conductors allowed in a box that is 8" X 8" X 4"? 7. There are 78- #10 T-90 conductors to be connected in a box ( one marrette per pair of wires) what is the minimum size of box required for this application? 8. What is the minimum standard device box required for the following situation: - one standard duplex receptacle - three, 14/2 NMD-90 cables - one, 14/3 NMD-90 cable - six marrettes for connections

1 2 Pull Box and Junction Box Sizinl! A pull box or junction box is sized according to rule 12-3036. This rule applies to boxes containing conductors or cables #4 A WG or larger, regardless whether or not they are in a raceway or part of a cable assembly. The intent of this rule is to prevent damage to the conductors when they are pulled or installed into the box. The rule is broken down into three major sections. Part one: The first section deals with the depth of the box. The rule states that the minimum depth of the box is found by multiplying the largest conductor by 6 and then adding the diameter of the largest raceway or equivalent cable. Part two: The second section deals with straight pulls. This is defined as when raceways or cables enter the box from one side and exit the box from the opposite side. The minimum dimension for this measurement is found by multiplying the largest raceway or equivalent cable by 8. Part three: The third section deals with angle pulls and "U" pulls. The minimum dimension is found by multiplying the largest raceway by 6 and then adding the remainder of the raceways. Part three A: There is another part of the rule that explains the minimum dimension between two conduits of an angle pull. This is simply found by multiplying the largest raceway or equivalent cable by 6 times. Before any examples, it is important to understand that we must take the largest calculated dimension in order to find the correct size of box. A box has four sides. We must make four calculations based on the information given in rule 12-3036 and use the largest for length and the largest for width. - -.-.--;: ------. 8. Examples: Part one: Box l. JJf'm :: 'X lat('ges DF A) 8; c. 0'. D AJ.ts 1We cmer 3 lj»bialr5 Part two: Part three:

9. 13 Pull Box and Junction Box Sizing: Practice Questions '-----'_ 2'1 3'1. 1 CD..1i-Jl- ' - - J - J -L~" A "! elil 'YJf~ + ~ - ' - r '- t- 1/; @ ~!' _., cj1,.." 3'" ~~'f '-- jlc r 3'. ~J{~- -1-,, d~'1 51 n 3 tf,f,y; L, e J i.. f" --'-.:~ h.. 1'/: ' 'A'l l - -. r - ( ~"-f r 3~' u 3,}{" " d.- ff ' ) J A!!, - ';! - i 5- ~. B.---, Ol" 'f't L,, ~-.f /. ~/ f 3..., T, 'lit (p! ~ ll(. "- ' / /. -;t '