TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

Similar documents
Notes on Rubber Friction

INFLUENCE OF NORMAL FORCE AND HUMIDITY ON FRICTION AND WEAR OF UNLUBRICATED STEEL/ STEEL COUPLES

EUROMASTER HYDRAULIC PRESSBRAKES

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

Inverted Pendulum System

Physical Properties Testing Technical Bulletin

CHAPTER 6 FRICTION AND WEAR ANALYSIS FOR BUSHING

Product Description. Further highlights. Outstanding features. 4 Bosch Rexroth Corporation Miniature Linear Modules R310A 2418 (2009.

Dynamic Tests on Ring Shear Apparatus

EUCLID M2 MIRROR MECHANISM

Mechanics. Centrifugal force Dynamics. What you need: Complete Equipment Set, Manual on CD-ROM included. What you can learn about

MDR 3000 Professional Professional Moving Die Rheometer. Testing instruments. Laboratory Equipment. Software systems. Service.

Finite Element Models for European Testing: Side Impact Barrier to WG13 Pedestrian Impactors to WG17

Experimental study of the frictional heating phenomenon in elastomers

SYNCHROMASTER HYDRAULIC PRESSBRAKES

Lecture 6 Friction. Friction Phenomena Types of Friction

Pre-owned - 8 colour press FA-Line: FA-4* NEXT CLEANINKING #F4733 MODULAR 16" MULTI-SUBSTRATE FLEXO PRESS

197 1st Avenue, Suite 120, Needham MA Tel Fax

Selection Calculations For Linear & Rotary Actuators

Principles Of Engineering. Part A

University of Bath. Publication date: Document Version Early version, also known as pre-print. Link to publication

Figure 43. Some common mechanical systems involving contact.

ROCK TRIBOLOGY USING TRIBOMETER

FIFA Quality Concept for Football Turf. Handbook of Test Methods. January 2008 Edition

Experiment Two (2) Torsional testing of Circular Shafts

THE LOSMANDY G-11 MOUNT

Sensor Accessories. Rotary Motion Accessory Pack. Pendulum Rod with two masses, Angular Momentum disc set and Linear Rack with mini c-clamp

Circular Motion and Centripetal Force

Sensors and Transducers. mywbut.com

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

Foundations of Ultraprecision Mechanism Design

NATIONAL CERTIFICATE (VOCATIONAL) APPLIED ENGINEERING TECHNOLOGY NQF LEVEL 4 NOVEMBER 2009

2. (a) Differentiate between rare metal thermocouples and base metal thermocouples.

Coating K = TFE wear resist, dry lubricant Kerkote X = Special coating, (Example: Kerkote with grease)

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Key words: Polymeric Composite Bearing, Clearance, FEM

Silicon Capacitive Accelerometers. Ulf Meriheinä M.Sc. (Eng.) Business Development Manager VTI TECHNOLOGIES

Drive Units with Ball Screw Drives R310EN 3304 ( ) The Drive & Control Company

Which one of the following correctly describes the velocities of the two bodies after the collision?

Moment of inertia and angular acceleration with Cobra 3

Impulsive loading on reinforced concrete slabs - blast loading function N. Duranovic & A.J. Watson Department of Civil and Structural Engineering,

Dynamic Mechanical Analysis of Solid Polymers and Polymer Melts

IDENTIFICATION OF FRICTION ENERGY DISSIPATION USING FREE VIBRATION VELOCITY: MEASUREMENT AND MODELING

PORTMORE COMMUNITY COLLEGE ASSOCIATE DEGREE IN ENGINEERING TECHNOLOGY

AF SERIES AWEA MECHANTRONIC CO., LTD. High Performance Vertical Machining Center AGENT ISO 9001 ISO 14001

INVESTIGATION OF FRICTION HYSTERESIS USING A LABORATORY- SCALE TRIBOMETER

SKF actuators available for quick delivery. Selection guide

ER2 Short-head Electric Chain Hoist

Peltier Application Note

A CRITERION OF TENSILE FAILURE FOR HYPERELASTIC MATERIALS AND ITS APPLICATION TO VISCOELASTIC-VISCOPLASTIC MATERIALS

Friction of Polymer/Steel Gear Pairs

The basic dynamic load rating C is a statistical number and it is based on 90% of the bearings surviving 50 km of travel carrying the full load.

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

Active elastomer components based on dielectric elastomers

BioMechanics and BioMaterials Lab (BME 541) Experiment #5 Mechanical Prosperities of Biomaterials Tensile Test

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

Linear guide drives. Synchronous shafts The use of synchronous shafts enables several linear axes to be operated with one drive.

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

Moment of inertia and angular acceleration

Optical Method for Micro Force Measurement. Yusaku FUJII Gunma University

Pullout Tests of Geogrids Embedded in Non-cohesive Soil

Tushar R Banode, S B Patil. Abstract

A 954 C HD. Technical Description Hydraulic Excavator. Machine for Industrial Applications

Study Effect of Pads shapes on Temperature Distribution for Disc Brake Contact Surface

Extended Material Characterization MCR

Points. Precision Positioning Table TU. Variation. Major product specifications With flange

The Effect of Relative Humidity and Roughness on the Friction Coefficient under Horizontal Vibration

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

Thermal Interface Material Performance Measurement

OLED SSL Stakeholder Meeting Hollis Beagi Josh Cummins October Introduction to OLED Design and Test Method Development

Module I Module I: traditional test instrumentation and acquisition systems. Prof. Ramat, Stefano

Identification Number

DEVELOPMENT OF SEISMIC ISOLATION TABLE COMPOSED OF AN X-Y TABLE AND WIRE ROPE ISOLATORS

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

The Effect of Frequency and Amplitude of Vibration on the Coefficient of Friction for Metals

THE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY

SCB10H Series Pressure Elements PRODUCT FAMILY SPEFICIFATION. Doc. No B

ISO 178 INTERNATIONAL STANDARD. Plastics Determination of flexural properties. Plastiques Détermination des propriétés en flexion

PERFORMANCE EVALUATION OF OVERLOAD ABSORBING GEAR COUPLINGS

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Initial Stress Calculations

FORCE & MOTION Instructional Module 6

ACOUSTIC EMISSION CHARACTERISTICS OF SURFACE FRICTION IN BIO-MEDICAL APPLICATION

Tflex HD700 Thermal Reliability Report

Development of a probe traversing system for an open test section wind tunnel

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

HAWK TECHNOLOGY LTD.

Objectives: After completion of this module, you should be able to:

Centripetal and centrifugal force

KINEMATIC COUPLINGS. The good, the bad, the ugly MIT PSDAM AND PERG LABS

When a rigid body is in equilibrium, both the resultant force and the resultant couple must be zero.

Overview. Dry Friction Wedges Flatbelts Screws Bearings Rolling Resistance

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Strain Measurement Techniques for Composite Coupon Testing

Difference Between Fixed and Floating Reference Points AASHTO T-321

MODELLING A ROTA-DYNAMIC LUBRICANT TEST SYSTEM FOR DETERMINING ENGINE SERVICE-LIFE PERFORMANCE. Nordin Othman, Yeo Kiam Beng & Lim Nam Piew

This chapter introduces the description of the surface interaction mechanism based on the friction, wear and excavation laws.

Newton s 2nd Law with demonstration track and Cobra4

Dynamics of Machinery

Which row, A to D, in the table correctly shows the quantities conserved in an inelastic collision? mass momentum kinetic energy total energy

Transcription:

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE Background: The Research Rubber Friction Test Machine offers the ability to investigate fully the frictional behaviour of rubbery materials both in dry and lubricated environments. It can also be used to study the friction of cosmetic products by using a suitable model for human skin. Typical contact configurations are ball on rubber flat and plate on rubber hemisphere. Thin rubber sheet samples may be tested by clamping them against a rubber backing. Other items such as threads, gloves and seals may be tested by the provision of suitable holders. The TE 75R was developed under licence from Rubber Consultants, part of the UK Malaysian Rubber Producers Research Association. The control unit includes a SLIM 2000 Serial Link Interface Module and COMPEND 2000 Windows based control and data acquisition software.

In rubber the friction force depends strongly on the real contact area between the rubber and counter surface, the interfacial shear strength and the deformation properties of the rubber. Each of these factors depends on others. The area of contact relates to the hardness and surface roughness, the applied load and the relative radius of curvature of the contacting surfaces. The interfacial shear strength depends on the polymer itself and the presence or absence of lubricants, solid or liquid. For the sliding of rubber against a rough (abrasive) surface such as silicon carbide paper there is a gradual change in friction with sliding rate. This is understood in terms of a combination of effects including adhesion, ploughing hysteresis and tearing. To make measurements of the friction coefficient of rubber it is important to have a well-defined contact geometry. A flat-on-flat geometry tends to give poor repeatability due to problems associated with achieving and holding the surfaces flat against each other. This requires both the production of smooth, flat surfaces and also a rigid test machine. Even if the specimens can be held in the correct orientation there are still problems associated with frictional tilt during motion. This tilt is a direct result of the flexibility or low elastic modulus of the rubber material. A metal ball on a pivoted arm loaded against a rubber flat will indent to a considerable distance. This indentation gives rise to two effects. First the line of action of the friction force shifts out of the horizontal plane. Second the large contact area gives rise to high friction force, even at quite modest normal loads. In both these respects rubber differs from harder materials such as metals and ceramics and this must be catered for in the machine design. The TE 75R was designed with this specific effect in mind. The friction force measurement is independent of the degree of misalignment or indentation of the samples. This was achieved by having the load and force axes at right angles and by allowing the link to the force transducer to slide vertically. An additional requirement was to have sensitive force measurement at small normal loads to address aspects of friction due to adhesion. Tests can be carried out with flat-on-flat and ball-on-flat (or reverse). The ball-on-flat geometry has been adopted by a number of researchers and they report much improved reproducibility of friction data compared to flat-on-flat geometry. The area of contact is defined by the elastic deformation of the rubber on a macro scale and this makes the contact effectively self-aligning. Variable test parameters include speed, stroke, sliding path, load, contact geometry, contact time or dwell period (dwell before initial sliding), lubrication, gaseous environment, temperature and relative humidity. Description: The fixed upper sample is loaded by dead-weights onto a sample mounted on a single axis linear traverse. As the lower sample moves the friction force on the upper sample is measured.

The TE 75R has a trunnion and gimble mounted loading beam, counterbalanced both to give a neutral balance and to bring the centre of gravity onto the contact plane. Load is applied by dead weights in a range from 0.1 N to 20 N. The load beam lift/drop is servo controlled so that the load can be applied at a specific point in the test. The program can also introduce a dwell between load application and movement. This dwell period can be crucial in determining the start-up friction in elastomers as the adhesive forces will increase the contact area over time. The loading beam is restrained by a strain gauge force transducer in a sliding link. This link ensures that only the tangential component of force in the contact (the friction force) is measured even with the large deflections associated with rubber test pieces. Dual Axis Traverse: The TE 75R has X and Y axis movement with linear positional feedback. Tangential (friction) force measurement is in the X direction. The axes are crossed linear slides with 1 mm pitch lead screws and are driven by geared dc motors. The X-AXIS drive has interchangeable belt reductions to give an overall speed turn-down of 1000:1. The Y-AXIS is direct coupled to a smaller motor giving a maximum index speed of 10 mm/min. The control strategy assumes that X = 0, Y = 0 is at the very centre of lower test specimen. Therefore all X traverses begin at a negative position equal to half the selected stroke. The operator only needs to select the required stroke, the software derives the starting point. The operator selects the required starting point for the Y AXIS indexing and this is termed the INITIAL Y OFFSET. If this is set to 0 the Y slide will begin at the centre of the specimen. To reach the edge of the specimen, INITIAL Y OFFSET = (Width of specimen)/2. By combining the X-AXIS movement with the Y-AXIS indexing function a number of motion types can be configured. These are defined as follows: INDEX = 0 The outward and return strokes are at the same Y position. This provides simple reciprocation along one track. INDEX > 0 The Y AXIS is indexed between each stroke by an amount defined by the Y INDEX DISTANCE, thus each outward and return stroke is separated on the surface. The wear track resembles a square wave. LOOP In this case a closed loop is defined whose width is defined by the Y INDEX DISTANCE and length by the STROKE LENGTH. In this way a test may be performed both on continuously fresh surface or on the same track approached from either direction. This latter feature is important for elastomers which show a direction dependence of wear due to plucking and tearing.

Test Environment: Since both samples are simple and the fixing arrangements are flexible a variety of shapes and counter-surface materials may be accommodated. The plate sample size is typically 25 mm square. The fixture for the lower (moving) specimen includes an electrical resistance heater and two thermocouples for temperature measurement and control above ambient conditions. The machine is provided with a plastic safety cover, which also acts as a chamber for the user to run under controlled humidity conditions. An ambient temperature and humidity sensor is mounted on the machine base inside the chamber. TE 75/C Peltier Cooler: This test assembly replaces the standard fixed specimen heater block assembly with a Peltier cooler pad. With water cooling of the hot side of the Peltier devices temperatures from -15 C to ambient may be achieved. Used in conjunction with the RE 75/C Laboratory Chiller unit with water/glycol mixture as the coolant, temperatures from -35 C to ambient may be achieved. To avoid ice formation, this adapter is best used in conjunction with a simple desiccant dehumidifier system used in conjunction with a controlled air supply. Control and Data Acquisition: The TE 75R has PC based sequence programmable control and data acquisition. This is provided by an integrated Serial Link Interface Module and COMPEND 2000 software running on a host PC, operating under Windows. Data is stored to hard disc in standard spread sheet compatible file formats (.csv or.tsv). Tests are defined by a sequence of steps, each step containing set-point, data recording rates and alarm level information. Set-points may be adjusted by step change or ramp. The test sequence is followed unless interrupted by the operator or an alarm. Set-points may also be adjusted manually using on screen toggles. Technical Specifications: Contact Configurations: Ball on Plate Plate on Plate Plate on Hemisphere Customised specimens possible Normal Load: 0.1 to 50 N Friction Force Range: X Axis Speed Ranges: 0 to 50 N 0.9 mm/s to 10 mm/s 0.05 to 0.9 mm/s 0.01 to 0.09 mm/s X Stroke: 1 to 50 mm Y Index Speed: 10 mm/min maximum Y Index: +/- 9 mm in steps of 0.5 mm Temperature Range: ambient to 100 C Dwell (time delay): User selected in seconds up to 8 hours Humidity Sensor: 10 to 90% RH

Temperature Sensor: J-type thermocouple Heating Power: 150 W Interface: SLIM 2000 Serial Link Interface Module Software COMPEND 2000 Motor: 125 W dc Controlled Parameters Recorded Parameters TE 75/C Peltier Cooler X Position X Axis Speed Y Position Y Axis Speed Temperature Dwell Period Test Duration X Position Y Position Humidity Temperature Friction Friction Coefficient Minimum Temperature: -15 C (ambient water cooled) Minimum Temperature: -35 C (chiller water/glycol cooled) RE 75/C Laboratory Chiller Working Fluid: Fluid Temperature: Services: Electricity: Installation: Bench-mounting machine: Bench-mounting controller: Packing Specifications: Order As: 50:50 Water/Glycol -30 C 220/240 V, single phase, 50 Hz, 720 W 110/120 V, single phase, 60 Hz, 720 W 570 mm x 600 mm x 600 mm high, 40 kg 530 mm x 530 mm x 240 mm high, 20 kg 0.59 m 3, GW 120 kg, NW 70 kg TE 75R Research Rubber Friction Test Machine TE 75/C Peltier Cooler RE 75/C Laboratory Chiller Copyright 2011 Phoenix Tribology Ltd