Unfinished Bolt ordinary, common, rough or black bolts High strength Bolt friction type bolts

Similar documents
Job No. Sheet 1 of 6 Rev B. Made by IR Date Oct Checked by FH/NB Date Oct Revised by MEB Date April 2006

Application nr. 7 (Connections) Strength of bolted connections to EN (Eurocode 3, Part 1.8)

CONNECTION DESIGN. Connections must be designed at the strength limit state

Timber and Steel Design. Lecture 11. Bolted Connections

D e s i g n o f R i v e t e d J o i n t s, C o t t e r & K n u c k l e J o i n t s

Example 4: Design of a Rigid Column Bracket (Bolted)

FHWA Bridge Design Guidance No. 1 Revision Date: July 21, Load Rating Evaluation of Gusset Plates in Truss Bridges

Steel Structures Design and Drawing Lecture Notes

MODULE F: SIMPLE CONNECTIONS

Tension Members. ENCE 455 Design of Steel Structures. II. Tension Members. Introduction. Introduction (cont.)

Presented by: Civil Engineering Academy

Project data Project name Project number Author Description Date 26/04/2017 Design code AISC dome anchor. Material.

Design of Beams (Unit - 8)

db = 23.7 in B C D 96 k bf = 8.97 in tf = in k = 1.09 in 13 Fy = 50 ksi Fu = 65 ksi Member A-B, Interior column: A E

Direct and Shear Stress

JointsForTekla Ver January

PROFILE SIZES: CONNECTION FORCES BEAM : UB254X146X43 CONNECTION DETAIL: D b = mm W b = mm T b = mm t wb = 7.30 mm r b = 7.

2014 MECHANICS OF MATERIALS

7.3 Design of members subjected to combined forces

Design of Steel Structures Dr. Damodar Maity Department of Civil Engineering Indian Institute of Technology, Guwahati

Structural Steelwork Eurocodes Development of A Trans-national Approach

Example 1 - Single Headed Anchor in Tension Away from Edges BORRADOR. Calculations and Discussion

Slip Critical Bolted Connections A Reliability Analysis for Design at the Ultimate Limit State

Steel connections. Connection name : MEP_BCF_W=14.29[mm]_W=6.35[mm]_tp=63.5[mm]_N=0_N=2_N=0_N=1_W=14.29[mm]_W=14.29[mm]_W=14.29[ mm] Connection ID : 1

Module 6. Shear, Bond, Anchorage, Development Length and Torsion. Version 2 CE IIT, Kharagpur

BLOCK SHEAR BEHAVIOUR OF COPED STEEL BEAMS

CHAPTER 4. Stresses in Beams

SHEAR CONNECTION: W BEAM WITH SHEAR PLATE ONE-WAY SHEAR CONNECTION TO W COLUMN WEB

CALCULATION MODE FOR ALUHD23/SH18 Traction and shear aluminium plate for Alufoot R system

2012 MECHANICS OF SOLIDS

FRICTION SLIPPING BEHAVIOR BETWEEN CONCRETE AND STEEL -AIMING THE DEVELOPMENT OF BOLTED FRICTION- SLIPPING JOINT -

Design of Steel Structures Prof. Damodar Maity Department of Civil Engineering Indian Institute of Technology, Guwahati

Job No. Sheet No. Rev. CONSULTING Engineering Calculation Sheet. Member Design - Steel Composite Beam XX 22/09/2016

[5] Stress and Strain

S E C T I O N 1 2 P R O D U C T S E L E C T I O N G U I D E - H E L I C A L S C R E W P I L E F O U N D A T I O N S

Design of Steel Structures Dr. Damodar Maity Department of Civil Engineering Indian Institute of Technology, Guwahati

Note to reviewers: See next page for basis for the change shown on this page. L-3160 TANGENTIAL CONTACT BETWEEN FLANGES OUTSIDE THE BOLT CIRCLE

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

BE Semester- I ( ) Question Bank (MECHANICS OF SOLIDS)

SIMPLE MODEL FOR PRYING FORCES IN T-HANGER CONNECTIONS WITH SNUG TIGHTENED BOLTS

DESIGN AND DETAILING OF COUNTERFORT RETAINING WALL

8 Deflectionmax. = 5WL 3 384EI

BLOCK SHEAR BEHAVIOUR OF BOLTED GUSSET PLATES

CHAPTER 2 LITERATURE REVIEW

Design against fluctuating load

db = 23.7 in B C D 96 k bf = 8.97 in tf = in k = 1.09 in 13 Fy = 50 ksi Fu = 65 ksi Member A-B, Interior column: A E

In-plane Shear Lag of Bolted Connections

CHAPTER 8 SCREWS, FASTENERS, NONPERMANENT JOINTS

BASE PLATE CONNECTIONS

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

MECHANICS OF MATERIALS. Prepared by Engr. John Paul Timola

PIXEL DUMMY SUPPORT TUBE LIFTING DEVICE ENGINEERING CALCULATION

Structural Steelwork Eurocodes Development of A Trans-national Approach

COURSE TITLE : APPLIED MECHANICS & STRENGTH OF MATERIALS COURSE CODE : 4017 COURSE CATEGORY : A PERIODS/WEEK : 6 PERIODS/ SEMESTER : 108 CREDITS : 5

SKILLS Project. October 2013

No , ss

Levers. 558 A Textbook of Machine Design

THEORETICAL DESIGN OF A NAILED OR BOLTED JOINT UNDER LATERAL LOAD 1. Summary

Simple Stresses in Machine Parts

BLOCK SHEAR CONNECTION DESIGN CHECKS

Theoretical Calculation and Experimental Study On Sung Torque And Angle For The Injector Clamp Tightening Bolt Of Engine

CH. 5 TRUSSES BASIC PRINCIPLES TRUSS ANALYSIS. Typical depth-to-span ratios range from 1:10 to 1:20. First: determine loads in various members

Fundamentals of Structural Design Part of Steel Structures

STEEL. General Information

Application nr. 3 (Ultimate Limit State) Resistance of member cross-section

QUESTION BANK SEMESTER: III SUBJECT NAME: MECHANICS OF SOLIDS

Accordingly, the nominal section strength [resistance] for initiation of yielding is calculated by using Equation C-C3.1.

Hilti North America Installation Technical Manual Technical Data MI System Version

APOLLO SCAFFOLDING SERVICES LTD SPIGOT CONNECTION TO EUROCODES DESIGN CHECK CALCULATIONS

SHEAR LAG IN SLOTTED-END HSS WELDED CONNECTIONS

: APPLIED MECHANICS & STRENGTH OF MATERIALS COURSE CODE : 4021 COURSE CATEGORY : A PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

CLUTCHES AND BRAKES. Square-jaw clutch

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Local buckling is an extremely important facet of cold formed steel

Riveted Joints C H A P T E R. 9.1 Introduction

AE302,ME302,DAE14,DME14

WORKED EXAMPLES, VALIDATION

my!wind Ltd 5 kw wind turbine Static Stability Specification

S19 S19. (1997) (Rev ) (Rev. 2 Feb. 1998) (Rev.3 Jun. 1998) (Rev.4 Sept. 2000) (Rev.5 July 2004) S Application and definitions

Longitudinal strength standard

The University of Melbourne Engineering Mechanics

BRACING MEMBERS SUMMARY. OBJECTIVES. REFERENCES.

Structural Steelwork Eurocodes Development of A Trans-national Approach

Determine the resultant internal loadings acting on the cross section at C of the beam shown in Fig. 1 4a.

A CONNECTION ELEMENT FOR MODELLING END-PLATE CONNECTIONS IN FIRE

Dimensions of propulsion shafts and their permissible torsional vibration stresses

CHAPTER 6: ULTIMATE LIMIT STATE

my!wind Ltd 5 kw wind turbine Static Stability Specification

MECE 3321 MECHANICS OF SOLIDS CHAPTER 1

Chapter Objectives. Design a beam to resist both bendingand shear loads

COLUMN BASE WEAK AXIS ALIGNED ASYMMETRIC FRICTION CONNECTION CYCLIC PERFORMANCE

STEEL BUILDINGS IN EUROPE. Multi-Storey Steel Buildings Part 8: Description of member resistance calculator

Structural Steelwork Eurocodes Development of a Trans-National Approach

N = Shear stress / Shear strain

QUESTION BANK DEPARTMENT: CIVIL SEMESTER: III SUBJECT CODE: CE2201 SUBJECT NAME: MECHANICS OF SOLIDS UNIT 1- STRESS AND STRAIN PART A

RESILIENT INFRASTRUCTURE June 1 4, 2016

Samantha Ramirez, MSE. Stress. The intensity of the internal force acting on a specific plane (area) passing through a point. F 2

Failure in Flexure. Introduction to Steel Design, Tensile Steel Members Modes of Failure & Effective Areas

Shared on QualifyGate.com

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

Chapter. Materials. 1.1 Notations Used in This Chapter

Transcription:

Bolted Connections Introductions: Connections are always needed to connect two members. It is necessary to ensure functionality and compactness of structures. Prime role of connections is to transmit force from one component to another. Steel connections can be made by bolts or welds. Connections accounts for more than half cost of steel structure. Connections are designed more conservative than members because they are more complex. Types of Bolts Unfinished Bolt ordinary, common, rough or black bolts High strength Bolt friction type bolts Classifications of Bolted connections: Based on Joint: Lap Joint Butt Joint Based on Load transfer Mechanism: Shear and Bearing, Friction Grade classification of Bolts: The grade classification of a bolt is indicative of the strength of the material of the bolt. The two grade of bolts commonly used are grade 4.6 and 8.8. For 4.6 grade 4 indicates that ultimate tensile strength of bolt = 4 100 = 400 N/mm 2 and 0.6 indicates that the yield strength of the bolt is 0.6 ultimate strength = 0.6 400 = 240 N/mm 2 Grade bolt of 4.6 5.6 6.5 6.8 8.8 Fyb( N/mm 2 ) 240 300 300 480 640 Fub( N/mm 2 ) 400 500 600 800 800 Properties of High Strength Friction Grip Bolts

Common Terms in Bolted Connections: Gauge Line: This is a line parallel to the direction of stress (or load) along which the bolts are placed. Pitch: It is the distance between the centres of two consecutive bolts measured along a row of bolts (Gauge Line). It is denoted by p. Gauge Distance: This is the perpendicular distance between adjacent gauge lines. It is denoted by g. Edge Distance: This is the shortest distance from the edge of the member to the extreme bolt hole centre along the Gauge line. End Distance: It is the shortest distance from the edge of the member to the extreme bolt hole centre perpendicular to the Gauge line. IS 800: 2007 Provisions: Clearance for Holes for Fastener (Bolts) (IS 800:2007 Clause 10.2.1, page no. 73) The diameter of the hole should be the nominal diameter of the bolt plus the clearance as given below: Nominal size of fastener, d mm Standard Clearance for Fastener Holes (IS 800: 2007, Table no. 19) Size of the hole = Nominal diameter of the fastener + Clearance Standard clearance in Over size clearance Clearance in the length of diameter and in the slot width of slot mm diameter Short slot mm Long slot mm 12-14 1.0 3.0 4.0 2.5d 16-24 2.0 4.0 6.0 2.5d 24 2.0 6.0 8.0 2.5d More than 24 3.0 8.0 10.0 2.5d Minimum pitch: (IS 800:2007, Clause 10.2.2, page no. 73) The distance between the centres of the bolts in the direction of stress should not be less than 2.5 times the nominal diameter of the bolt Maximum pitch (IS 800:2007, Clause 10.2.3, page no. 74) 32t or 300 mm, whichever is less for the bolts in members including the tacking bolts. (Clause 10.2.3.1, page no. 74)

16t or 200 mm, whichever is less for the bolts in tension members, Where t is the thickness of thinner plate (Clause 10.2.3.2, page no. 74) 12t or 200 mm, whichever is less for the bolts in compression members, Where t is the thickness of thinner plate (Clause 10.2.3.2, page no. 74) Edge and End distance (IS 800:2007, Clause 10.2.4.2, page no. 74) Minimum edge and end distances from the centre of any hole to the nearest edge of a plate should not be less than 1.7 times the hole diameter for sheared or hand- flame cut edges; and 1.5 times the hole diameter for rolled, machine-flame cut, sawn and planned edges Maximum edge distance from the centre of hole to the nearest edge should not exceed 12tε, where ε = sqrt(250/fy) and t is the thickness of the thinner outer plate. Tacking Bolts (IS 800:2007, Clause 10.2.5.2, page no. 74) These are the additional bolts provided other than strength consideration. The maximum pitch of these bolts should be 32t or 300 mm, whichever is less, where t is the thickness of the thinner plate. If the members are exposed to weather, the pitch should not exceed 16 times the thickness of the outside plate or 200 mm, whichever is less. Strength Provisions: The design Strength Vdb of bolt is lesser of 1. Design shear strength Vdsb of bolt, and 2. Design bearing strength Vdpb of bolt. Shear Capacity of a Bolt (IS 800:2007, Clause 10.3.3, page no. 75) The design strength of a bolt in shear Vdsb is given by Where, V dsb = V nsb V nsb = fu 3 [n na nb + n s A sb ] Vnsb = nominal shear capacity of a bolt fu = Ultimate tensile strength of the bolt material nn = Number of shear planes with threads intercepting the shear plane ns = Number of shear planes without threads intercepting the shear plane.

Asb =Nominal plain shank area of the bolt Anb = Net shear area of the bolt at threads = Area corresponding to root diameter at the thread = π 4 [d 0.9382p]2 (I.S. 1367 part-1) = 0.78 to 0.80 of gross area of shank (see table) γmb = Partial safety Factor of safety for the bolt material = (IS 800:2007, Table 5, page no. 30) Bearing Capacity of a Bolt (IS 800:2007, Clause 10.3.4, page no. 75) The design strength of a bolt in bearing Vdpb is given by Where, V dpb = V npb Vnpb = 2.5kb dtfu Vnpb = nominal bearing strength of a bolt kb = smallest of e 3d0, p 3d 0 0.25, f ub f u, 1 e, p = end and pitch distances of the fastener along bearing direction do = diameter of hole d = nominal diameter of the bolt t = summation of the thickness of the connected plates experiencing bearing stress in the same direction, or if the bolts are counter sunk, the thickness of the plate minus one half of the depth of counter sinking. Tension Capacity of a Bolt (IS 800:2007, Clause 10.3.5, page no. 76) The design strength of a bolt in tension Tdb Where, Tdb = T nb T nb = 0.9 f ub A nb < f yb A sh γ mo Tnb = Nominal tensile capacity of the bolt, calculated as, fub = yield stress of the bolt An = Net tensile stress area = area at bottom of the threads, and Ash = Shank area of the bolt γmo = Partial safety factor for resistance governed by yielding = 1.10 γmb = Partial safety factor for material of bolt

Bolt subjected to Combined Shear and Torsion (IS 800:2007, Clause 10.3.6, page no. 76) A bolt subjected to shear and torsion simultaneously should satisfy the condition ( V 2 sb ) V db + ( T 2 b ) T db 1 Where, Vsb = Factored shear force acting on the bolt Vdb = Design shear capacity of the bolt Tb = Factored tensile force acting on the bolt Tdb = Design tensile capacity of the bolt Bolt subjected to Friction (IS 800:2007, Clause 10.4.3, page no. 76) V dsf = V nsf γ mf Where, Vnsf = μf ne Kh Fo μf = coefficient of friction (slip factor) as specified in Table 20 (μf = 0.55 ne = number of effective interfaces offering frictional resistance to slip Kh = 1.0 for fasteners in clearance holes, = 0.85 for fasteners in oversized and short slotted holes loaded perpendicular to the slot. γmf = 1.10 (if slip resistance is designed at service load = (if slip resistance is designed at ultimate load Fo = minimum bolt tension (proof load) at installation and may be taken as Anb fo Anb = Net shear area of the bolt at threads fo = proof stress ( = 0.70fub ) Load Transmission by Different Types of Bolts Load transmitted by Black Bolt (bearing type) Due to load the plates slip so as to come into contact with edges of the hole. The load transmission is by baring of the bolt and shear on the shank. Load transmission by High Strength friction grip Bolt In this case tightening the nut tension T is transmitted to the bolt to reach tensile stress equal to 0.8 to 0.9 times the yield stress.

As a consequence of this initial tension in the bolt, the two plates get tightly clamped together. If the tensile force in the bolt is T, a compressive force T becomes the clamping force. Plates are prevented from slipping due to frictional resistance F whose value is μt, where μ is coefficient of friction between the plate surfaces. If pull P applied to the plates is less than μt, plates do not slip at all and the load transmission from one plate to other place entirely by frictional resistance only. IF the applied force P exceed μt, slip between the plate occurs resulting in shearing and bearing stresses in the bolt. Strength Black bolt or Bearing Type bolt Slip Resistance HSFG Bolt Non-slip resistance Shear Strength Bearing Strength Tensile Strength Frictional Strength Example:1 Two plates 200mm 8mm are to be connected by 16mm diameter bolts in a lap joint. Calculate the strengths for the black type (Bearing type bolts). Take 4.6 grade of bolts. Take ultimate tensile strength of plate = 410 N/mm 2.

Given Data: d = 16mm do= 16 + 2 = 18 mm (Table 19, Page no. 19, Page no. 73) t = thickness of plate = 8 mm Shear Strength (IS 800:2007, Clause 10.3.3, page no. 75) V dsb = V nsb V nsb = fu 3 [n na nb + n s A sb ] V dsb = 400 3 [(1 0.78 π 4 162 ) + (0 π 4 162 )] = 28.97 kn Bearing Capacity:(IS 800:2007, Clause 10.3.4, page no. 75) V dpb = V npb Vnpb = 2.5kb dtfu V dpb = 2.5 0.741 16 8 410

Kb is least of e/3do = 40/(3 18) = 0.741; p/3do 0.25 = [60/(3 18)] 0.25 = 0.86; fub/fu = 400/410 = 0.976; 1 = 77.77 kn Example:2 Determine the design strength of 22mm dia. Bolt for the cases given below. (1). Lap Joint (2) Single cover butt joint with 12mm cover plate. (3) Double cover butt joint with 10mm cover plate. Consider main plate is 16mm thick. Take 4.6 grade of bolts. Take ultimate tensile strength of plate = 410 N/mm 2. Given Data: d = 22mm do= 22 + 2 = 24 mm (Table 19, Page no. 19, Page no. 73) t = thickness of plate = 16 mm Case 1: Shear Strength (IS 800:2007, Clause 10.3.3, page no. 75) V dsb = V nsb V nsb = fu 3 [n na nb + n s A sb ] V dsb = 400 3 [(1 0.78 π 4 222 ) + (0 π 4 222 )] = 54.78 kn Bearing Strength:(IS 800:2007, Clause 10.3.4, page no. 75) V dpb = V npb Vnpb = 2.5kb dtfu V dpb = 2.5 0.556 22 16 410 = 160.48 kn e = 1.5 do = 1.5 24 = 36 40mm p = 2.5d = 2.5 22 = 55 60 mm Kb is least of e/3do = 40/(3 24) = 0.556; p/3do 0.25 = [60/(3 24)] 0.25 = 0.58; fub/fu = 400/410 = 0.976; 1 t = 16mm d = 22mm

Case 2: Single cover butt joint with 12mm cover plate Shear Strength (IS 800:2007, Clause 10.3.3, page no. 75) V dsb = 54.78 Bearing Strength:(IS 800:2007, Clause 10.3.4, page no. 75) 2.5 0.556 22 12 410 V dpb = = 120.36 kn Case 3: Double cover butt joint with 10mm cover plate. Shear Strength (IS 800:2007, Clause 10.3.3, page no. 75) V dsb = 2 54.78 = 109.56 kn Bearing Strength:(IS 800:2007, Clause 10.3.4, page no. 75) 2.5 0.556 22 16 410 V dpb = = 160.48 kn Example 3: Find the efficiency of the butt join shown in figure. Bolts are 16mm diameter of grade 4.6. Cover plates are 8mm thick. Shear Strength (IS 800:2007, Clause 10.3.3, page no. 75)

V dsb = V nsb V nsb = fu 3 [n na nb + n s A sb ] V dsb = 400 3 [(2 0.78 π 4 162 ) + (0 π 4 162 )] = 57.95 kn Bearing Strength:(IS 800:2007, Clause 10.3.4, page no. 75) V dpb = V npb Vnpb = 2.5kb dtfu V dpb = 2.5 0.56 16 12 410 = 88.16 kn e = 30mm p = 50 mm Kb is least of e/3do = 30/(3 18) = 0.56; p/3do 0.25 = [50/(3 18)] 0.25 = 0.67; fub/fu = 400/410 = 0.976; 1 t = 16mm d = 12mm Strength of the Joint per pitch length Efficiency of the joint = [ Strength of solid plate per pitch Length ] 100 Strength the joint per pitch length = 57.95 kn Strength of solid plate per pitch length = 0.9A nf u γ m1 32,IS 800:2007) ( clause no. 6.3.1, page no.

= 0.9 (50 16) 12 410 = 120.44 kn Efficiency of the joint = [ 57.95 120.44 ] 100 = 48.11 % Example: An ISA 100mm 100mm 10mm carries a factored tensile load of 100kN.It is to jointed with a 12mm thick gusset plate. Design high strength bolted joint when, (a) no slip is permitted. (b) when slip is permitted. Take bolt grade =8.8 with 16mm dia. Solution: fub = 800 N/mm 2 for 8.8 grade. (a) Slip critical connection: Frictional Strenght (IS 800:2007, Clause 10.4.3, page no. 76) V dsf = V nsf γ mf Where, Vnsf = μf ne Kh Fo μf = coefficient of friction (slip factor) as specified in Table 20 (μf = 0.55) = 0.55 ne = number of effective interfaces offering frictional resistance to slip = 1 Kh = 1.0 for fasteners in clearance holes, = 0.85 for fasteners in oversized and short slotted holes loaded perpendicular to the slot. γmf = 1.10 (if slip resistance is designed at service load = (if slip resistance is designed at ultimate load Anb = Net shear area of the bolt at threads = (0.78 π 4 162 ) = 157mm 2 fo = proof stress ( = 0.70fub ) = 0.70 800 = 560 N/mm 2 Fo = minimum bolt tension (proof load) at installation and may be taken as Anb fo = 560 0.157 = 87. 9 kn

V dsf = μf ne Kh Fo γ mf 0.55 1 1 87.9 V dsf = = 38.65 kn Tension Capacity of a Bolt (IS 800:2007, Clause 10.3.5, page no. 76) The design strength of a bolt in tension Tdb Tdb = T nb T nb = 0.9 f ub A nb Tdb = 0.9 f ub A nb 0.9 800 157 = = 90.32 kn Bolt value = 38. 65 kn No. of bolt = 100 38.65 3 (a) Slip allowed connection: Shear Strength (IS 800:2007, Clause 10.3.3, page no. 75) V dsb = V nsb V nsb = fu 3 [n na nb + n s A sb ] V dsb = 800 3 [(1 0.78 π 4 162 ) + (0 π 4 162 )] = 58 kn Bearing Strength:(IS 800:2007, Clause 10.3.4, page no. 75) V dpb = V npb

Vnpb = 2.5kb dtfu V dpb = 2.5 0.56 16 10 410 = 73.47 kn e = 30mm p = 50 mm Kb is least of e/3do = 30/(3 18) = 0.56; p/3do 0.25 = [50/(3 18)] 0.25 = 0.67; fub/fu = 800/410 =; 1 t = 10mm d = 16mm Bolt value = 58 kn No. of bolt = 100 58 = 1.72 2 Example: An I beam ISLB400@558.2 N/m is to be connected to the web of a main beam ISLB550@846.6 N/m. The factor reaction of 220 kn. Design the connection if the cleat angel size is 110 110 6 as shown in figure. Use 20mm diameter bolts.

Properties from steel table: Properties Notation ISLB400 ISLB550 Height h 400 mm 550 mm Width of flange bf 165mm 190mm Thickness of flange tf 12.5mm 15mm Thickness of web tw 8mm 9.9mm h Connection between the angles and the web of the secondary beam: The connecting bolts are in double shear: Shear Strength (IS 800:2007, Clause 10.3.3, page no. 75) bf V dsb = V nsb V nsb = fu 3 [n na nb + n s A sb ] V dsb = 400 3 [(2 0.78 π 4 202 ) + (0 π 4 162 )] = 90.54 kn

Bearing Strength:(IS 800:2007, Clause 10.3.4, page no. 75) V dpb = V npb Vnpb = 2.5kb dtfu V dpb = 2.5 0.606 20 8 410 = 79.51 kn Bolt value = 79.51 kn e = 1.5 do = 1.5 22 = 33 40mm p = 2.5d = 2.5 20 = 50 60 mm Kb is least of e/3do = 40/(3 22) = 0.606; p/3do 0.25 = [60/(3 20)] 0.25 = 0.659; fub/fu = 400/410 = 0.976; 1 t = 16mm d = 22mm Number of bolts required = 220 = 2.78 3 bolts 79.51 Connection between the angles and the web of the main beam: The connecting bolts are in single shear: Shear Strength (IS 800:2007, Clause 10.3.3, page no. 75) Design strength of the bolt in single shear = 45.27 kn Bearing Strength:(IS 800:2007, Clause 10.3.4, page no. 75) V dpb = V npb Vnpb = 2.5kb dtfu

V dpb = 2.5 0.606 20 9.9 410 = 98.39 kn Bolt value = 45.27 kn Number of bolts required = 220 = 4.85 5 bolts 45.27