Atomic and nuclear physics

Similar documents
Atomic and nuclear physics

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

F 44 Normal Zeeman Effect

Atomic and nuclear physics

Mechanics. Determining the gravitational constant with the gravitation torsion balance after Cavendish. LEYBOLD Physics Leaflets P

Atomic and nuclear physics

Electricity. Measuring the force on current-carrying conductors in a homogeneous magnetic field. LEYBOLD Physics Leaflets P

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

Zeeman Effect - Lab exercises 24

The Zeeman Effect refers to the splitting of spectral

Solid-state physics. Laue diagrams: investigating the lattice structure of monocrystals. LEYBOLD Physics Leaflets P

THE ZEEMAN EFFECT PHYSICS 359E

Atomic Spectra HISTORY AND THEORY

Atomic spectra of one and two-electron systems

PHYSICS. Paper 1 (THEORY) Three hours and a quarter

2. OPERATIONAL CONDITIONS

Normal and anomalous Zeeman effect

THE ZEEMAN EFFECT v3 R. A. Schumacher, May 2017 B. B. Luokkala, January 2001

Zeeman effect. Introduction

Laboratory #29: Spectrometer

Lab #13: Polarization

Zeeman effect. Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, Heidelberg. 22nd May 2006

Physical Structure of Matter /07 Zeeman effect/ normal and anomalous version. Physics of the Electron. What you need:

The Zeeman Effect. Oisin De Conduin /2/2011

Physics 476LW. Advanced Physics Laboratory - Franck Hertz

THE DIFFRACTION GRATING SPECTROMETER

PHYSICS 253 SAMPLE FINAL EXAM. Student Number. The last two pages of the exam have some equations and some physical constants.

10. Wavelength measurement using prism spectroscopy

PH2200 Practice Final Exam Summer 2003

DISPERSION OF A GLASS PRISM

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT. Physics 211 E&M and Quantum Physics Spring Lab #9: Diffraction Spectroscopy

Department of Physics, Colorado State University PH 425 Advanced Physics Laboratory The Zeeman Effect. 1 Introduction. 2 Origin of the Zeeman Effect

Zeeman effect. Introduction. Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, Heidelberg. March 10, 2012

Coherence and width of spectral lines with Michelson interferometer

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION

Atomic Spectra. d sin θ = mλ (1)

ATOMIC SPECTRA. Objective:

Any first year text, sections on atomic structure, spectral lines and spectrometers

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

B.Tech. First Semester Examination Physics-1 (PHY-101F)

The Quantum Model of the Hydrogen Atom

The Grating Spectrometer and Atomic Spectra

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

Atomic and nuclear physics

2. Determine the excess charge on the outer surface of the outer sphere (a distance c from the center of the system).

The Grating Spectrometer and Atomic Spectra

Atomic and Nuclear Physics

PC1144 Physics IV. Atomic Spectra

Physics 476LW Advanced Physics Laboratory Michelson Interferometer

Practical 1P4 Energy Levels and Band Gaps

ONE-ELECTRON AND TWO-ELECTRON SPECTRA

Speed of Light in Air

Practical 1P4 Energy Levels and Band Gaps

GOVIND VIDYALAYA TAMULIA XII PHYSICS

Atomic and Nuclear Physics

Protokoll. Grundpraktikum II - Optical Spectroscopy

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

Zeeman Effect. Rabia Aslam Chaudary Roll no: LUMS School of Science and Engineering. Friday May 20, 2011

Pre-lab Quiz/PHYS 224. Your name Lab section

Atomic emission spectra experiment

Atomic and Nuclear Physics

YOUR NAME Sample Final Physics 1404 (Dr. Huang)), Correct answers are underlined.

To determine the wavelengths of light emitted by a mercury vapour lamp by using a diffraction grating.

Experiment #4: Optical Spectrometer and the Prism Deviation

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

Michelson Interferometer

Physics 23 Fall 1998 Lab 4 - The Hydrogen Spectrum

1. In Young s double slit experiment, when the illumination is white light, the higherorder fringes are in color.

Zeeman Effect. Alex Povilus Physics 441- Fall 2003 December 20, 2003

Obtain an optical "bench" setup (there should be three sliding mounts on the calibrated horizontal bar. The setup is shown in the diagram below.

PHYSICS PAPER 1 (THEORY)

n(λ) = c/v(λ). Figure 1: Dispersion curves for some common optical glass types.

PHYSICS ORDINARY LEVEL

STD : 12 TH GSEB PART A. 1. An electric dipole is placed in a uniform field. The resultant force acting on it...

Experiment O-2. The Michelson Interferometer

BLUE-PRINT II XII Physics

Electron Spin Resonance. Laboratory & Computational Physics 2

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student

The Zeeman Effect in Atomic Mercury (Taryl Kirk )

OPTICAL SPECTROSCOPY AND THE ZEEMAN EFFECT Beyond the First Year workshop Philadelphia, July Greg Elliott, University of Puget Sound

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

DIFFRACTION GRATING. OBJECTIVE: To use the diffraction grating in the formation of spectra and in the measurement of wavelengths.

Larbert High School. Quanta and Waves. Homework Exercises ADVANCED HIGHER PHYSICS

Physics 208 Review Questions

UNITED SCIENTIFIC SUPPLIES, INC. OPERATION AND EXPERIMENT GUIDE

Experiment 10. Zeeman Effect. Introduction. Zeeman Effect Physics 244


LABORATORY WRITE-UP MICHELSON INTERFEROMETER LAB AUTHOR S NAME GOES HERE STUDENT NUMBER:

LAB 12 ATOMIC SPECTRA

ATOMIC SPECTRA. To identify elements through their emission spectra. Apparatus: spectrometer, spectral tubes, power supply, incandescent lamp.

PHYS 102 Exams. PHYS 102 Exam 3 PRINT (A)

ZEEMAN SPLITTING. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

EXPERIMENT 12 THE GRATING SPECTROMETER AND ATOMIC SPECTRA

Physics 24, Spring 2007 Lab 2 - Complex Spectra

Speed of Light in Glass

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado

Lab in a Box Measuring the e/m ratio

Compendium of concepts you should know to understand the Optical Pumping experiment. \ CFP Feb. 11, 2009, rev. Ap. 5, 2012, Jan. 1, 2013, Dec.28,2013.

For more sample papers visit :

Transcription:

Atomic and nuclear physics Atomic shell Normal Zeeman effect LEYBOLD Physics Leaflets Observing the normal Zeeman effect in transverse and longitudinal Objects of the experiment Observing the line triplet for the normal transverse Zeeman effect. Determining the polarization state of the triplet components. Observing the line doublet for the normal longitudinal Zeeman effect. Determining the polarization state of the doublet components 0506-Sel Principles Normal Zeeman effect The Zeeman effect is the name for the splitting of atomic energy levels or spectral lines due to the action of an external magnetic field. The effect was first predicted by H. A. Lorenz in 1895 as part of his classic theory of the electron, and experimentally confirmed some years later by P. Zeeman. Zeeman observed a line triplet instead of a single spectral line at right angles to a magnetic field, and a line doublet parallel to the magnetic field. Later, more complex splittings of spectral lines were Fig. 1: Level splitting and transitions of the normal Zeeman effect in cadmium observed, which became known as the anomalous Zeeman effect. To explain this phenomenon, Goudsmit and Uhlenbeck first introduced the hypothesis of electron spin in 1925. Ultimately, it became apparent that the anomalous Zeeman effect was actually the rule and the normal Zeeman effect the exception. The normal Zeeman effect only occurs at the transitions between atomic states with the total spin S = 0. The total angular momentum J = L + S of a state is then a pure orbital angular momentum (J = L). For the corresponding magnetic moment, we can simply say that: = B J (I) where B = e (II) 2m e B = Bohr s magneton, m e = mass of electron, e elementary charge, = Planck s constant) In an external magnetic field B, the magnetic moment has the energy E = - B (III) The angular-momentum component in the direction of the magnetic field can have the values J z = M J mit M J = J, J 1,, -J (IV) Therefore, the term with the angular momentum J is split into 2J + 1 equidistant Zeeman components which differ by the value of M J. The energy interval of the adjacent components M J, M J+1 is E = B B (V). We can observe the normal Zeeman effect e.g. in the red spectral line of cadmium ( 0 = 643.8 nm, f 0 = 465.7 THz). It corresponds to the transition 1 D 2 (J = 2, S = 0) > 1 P 1 (J = 1, S = 0) of an electron of the fifth shell (see Fig. 1). 1

LEYBOLD Physics Leaflets Apparatus 1 Cadmium lamp for Zeeman effect..... 451 12 1 Optical system for observing the Zeeman effect.............. 471 20 1 Lummer-Gehrcke plate........... 471 21 1 Electromagnet for Zeeman effect..... 514 50 1 Universal choke for 451 12......... 451 30 1 High current power supply......... 521 55 Connecting leads with conductor cross-section 2.5 mm 2 In the magnetic field, the 1 D 2 level splits into five Zeeman components, and the level 1 P 1 splits into three Zeeman components having the spacing calculated using equation (V). Optical transitions between these levels are only possible in the form of electrical dipole radiation. The following selection rules apply for the magnetic quantum numbers M J of the states involved: = ±1 für -Components M J = 0 für -Components (VI) Thus, we observe a total of three spectral lines (see Fig. 1); the component is not shifted and the two components are shifted by f = ± E (VII) h with respect to the original frequency. In this equation, E is the equidistant energy split calculated in (V). Angular distribution and polarization Depending on the angular momentum component M J in the direction of the magnetic field, the emitted photons demonstrate different angular distributions. Fig. 2 shows the angular distributions in the form of two-dimensional polar diagrams. They can be observed experimentally, as the magnetic field is characterized by a common axis for all cadmium atoms. In classical terms, the case M J = 0 corresponds to an infinitesimal dipole oscillating parallel to the magnetic field. No quanta are emitted in the direction of the magnetic field, i.e. the component cannot be observed parallel to the magnetic field. The light emitted perpendicular to the magnetic field is linearly polarized, whereby the E-vector oscillates in the direction of the dipole and parallel to the magnetic field (see Fig. 3) Conversely, in the case M J = ±1, most of the quanta travel in the direction of the magnetic field. In classical terms, this case corresponds to two parallel dipoles oscillating with a phase difference of 90. The superpositioning of the two dipoles produces a circulating current. Thus, in the direction of the magnetic field, circularly polarized light is emitted; in the positive direction, it is clockwise-circular for M J = +1 and counterclockwise-circular for M J = 1 (see Fig. 3). Safety notes The electrical leads on the cadmium lamp and the resistors of the starting electrodes are open and easily accessible: Do not touch any current-carrying (live!) parts. The Lummer-Gehrcke plate has been manufactured with great precision with regard to the parallelism and flatness of its surfaces. Do not mechanically stress the Lummer-Gehrcke plate by bending or in any other manner. Pick up the Lummer-Gehrcke plate only by the edges. When mounting the Lummer-Gehrcke plate, make sure that the plate is supported evenly in its holder over its entire length. Before transporting the apparatus, remove the Lummer-Gehrcke plate from its holder and store it in a safe place. Loose ferromagnetic objects can be strongly attracted by the electromagnet and can damage the quartz bulb of the cadmium lamp. Check to make sure that the pole pieces are screwed tight before switching on the magnet current. When the magnet current is switched on, do not handle ferromagnetic objects in the vicinity of the cadmium lamp. Deposits of skin secretions can destroy the quartz bulb of the cadmium lamp when it becomes hot. Never handle the quartz bulb of the cadmium lamp with your bare hands. Fig. 2: Fig. 3: Angular distributions of the electrical dipole radiation ( M J : angular-momentum components of the emitted photons in the direction of the magnetic field) Schematic representation of the polarization of the Zeeman components Spectroscopy of the Zeeman components The Zeeman effect enables spectroscopic separation of the differently polarized components. To demonstrate the shift, however, we require a spectral apparatus with extremely high resolution, as the two components of the red cadmium line are shifted e.g. at a magnetic flux density B = 1 T by only f = 14 GHz, respectively = 0.02 nm. A Lummer-Gehrcke plate is used for this experiment. This component has been manufactured with great precision with respect to the parallelism and flatness of its surfaces. The light, which is divergent in the vertical direction, passes through a 2

LEYBOLD Physics Leaflets horizontal slit via an attached prism into a long, plane-parallel glass plate (see Fig. 4). Inside this plate, the light is reflected back and forth repeatedly, with some part of it emerging each time. When observed at an angle of 90, the reflection within the plate occurs almost completely within the limit angle of total reflection. The result is a high reflection coefficient, i.e. many of the rays can interfere with each other when the plate is long enough. The emerging waves are observed from behind the plate using a telescope focused on infinity. For a given wavelength, two mirror-image identical systems of horizontal lines can be observed above and below the plate. Each interference line can be assigned to one emerging angle of the component rays from the Lummer-Gehrcke plate and an angle of incidence at the prism. The rays emerging at an angle of k interfere constructively with each other when two adjacent rays fulfill the condition for curves of equal inclination (see Fig. 4): = 2d n 2 sin 2 k = k mit k = 1, 2, 3, (VIII) ( = optical path difference, d = thickness of plate, n = refractive index of the glass, k = order of interference) A change in the wavelength by appears as a shift in the interference lines by the angle. If a spectral line contains multiple components with a distance, each interference line is split into a corresponding number of components with the spacing. It thus becomes possible to recognize a spectralline doublet in a doublet structure and a spectral-line triplet in a triplet structure in the interference lines. Fig. 4: Setup Lummer-Gehrcke plate as an interference spectrometer (the beam path for the angle of incidence = 0 is drawn as a series of unbroken lines). The optical path difference between two adjacent emerging rays is = n 1 2 First-time setup: Fig. 5 shows the complete setup in the transverse. Mount the electromagnet for the Zeeman effect on the base plate of the optical system. When tightening the hex screw (size 27) beneath the base plate, make sure that you can still turn the electromagnet on the base plate when you really try. Mount the pole pieces of the electromagnet (a) at a spacing of 10 mm. Fig. 5: Experiment setup for the Zeeman effect in the transverse (a) pole pieces (b) cadmium lamp with holder (c) plug-in holder for red filter (d) cover (e) telescope (f) ocular (g) height adjustment for telescope (h) arresting screw for column (i) arresting screw for column base 3

LEYBOLD Physics Leaflets Fig. 6: Top view of setup in the transverse (top) and the longitudinal (bottom) (d1) holder with quarter-wavelength foil (e1) holder with polarization filter Screw in the holder for the cadmium lamp (b) with the opening facing the electrical connections of the electromagnet. Secure the pole pieces and the holder of the cadmium lamp using arresting screws and retaining straps. Turn the fused point on spectral lamp toward the side with the electrical connections so that the electrical leads do not obstruct the beam path. Screw in the column of the optical system so that the column base is as far as possible from the electromagnet. Remove the cover (d) and carefully place the Lummer- Gehrcke plate on the velour-lined base. Make sure the plate is aligned horizontally and is evenly supported over its entire length. Slide the prism as close as possible to the illuminated side. Turn the cover together with the cylindrical attachment toward the telescope (e) and rest it carefully against the telescope without disturbing the Lummer-Gehrcke plate. Then tighten the arresting screws. Slide the red filter with collecting lens into the plug-in holder (c). To prevent interference from ambient light, slide the flexible light screen onto the cylindrical attachment of the cover, and slide the foam rubber ring over the telescope. Switching from transverse to longitudinal observation: Loosen arresting screw (i) on the column base and move the column of the optical system as far as possible from the electromagnet. Remove the red filter with collecting lens from the plug-in holder. Swivel the electromagnet with cadmium lamp into the desired position (see Fig. 6) and align it so that the edge of the base plate of the electromagnet is parallel to the rear edge of the base plate of the optical system. Slide the red filter with collecting lens into the plug-in holder. Bring the column of the optical system and the electromagnet as close together as possible. Electrical connection: Connect the cadmium lamp to the universal choke. After switching on, wait five minutes until a sufficiently strong light intensity is obtained. Connect the coils of the electromagnet in parallel (connect socket 1 to socket 3 and socket 2 to socket 4) and connect this assembly to the high current power supply. Adjusting the optical system for observing the Zeeman effect: Adjust the height of the optical system in the longitudinal, and do not change it when swiveling to the transverse. The optical system is optimally adjusted when the red horizontal interference patterns above and below the Lummer- Gehrcke plate show maximum brightness and contrast. Remove the ocular of the telescope (f); to optimize brightness and contrast, alternately 4

LEYBOLD Physics Leaflets a) shift and swivel the entire optical system left and right on the base plate (fix with arresting screw (i)); b) set the height of the complete optical system in relation to the cadmium lamp and the hole in the pole pieces (fix with arresting screw (h)). To improve brightness and contrast of the lines, you may need to raise the entire cover or the red filter with collecting lens in the plug-in holder. Measuring example and evaluation a) Observing in the transverse : Fine adjustment: When the telescope is aimed precisely at the rear of the Lummer-Gehrcke plate, the interference lines appear symmetrically distributed between the top and the bottom. The bright inner lines are best suited for observation. Hold the ocular up to the light and focus the cross-hairs. Replace the ocular in the tube of the telescope and focus the interference lines by shifting the ocular. Carrying out the experiment Note: the polarization filter is somewhat darker than the quarter-wavelength foil. Fig. 7: Interference pattern for the Zeeman effect in the transverse a) observed without polarization filter b) observed with polarization direction of the filter perpendicular to the magnetic field c) observed with polarization direction of the filter parallel to the magnetic field b) Observing in the longitudinal : a) Observing in the transverse : First observe the pattern of interference lines without the magnetic field (I = 0 A) and align the telescope so that the cross-hairs of the ocular rest on an interference line. Slowly increase the magnet current to about I = 10 A, until the split lines are clearly separated from each other. To distinguish between the and the -components: Slide the foam rubber ring over the holder of the polarization filter. Place the holder with polarization filter (e1) over the telescope (see Fig. 6) and turn it around the axis of observation until the middle component of the line triplet disappears. Turn the holder with polarization filter 90 further until the outer components of the line triplet disappear. b) Observing in the longitudinal : First observe the pattern of interference lines without the magnetic field (I = 0 A) and align the telescope so that the cross-hairs of the ocular rest on an interference line. Slowly increase the magnet current to about I = 10 A, until the split lines are clearly separated from each other. To distinguish between the + and the components: Slide the flexible light screen onto the holder for the quarter-wavelength foil. Mount the holder with quarter-wavelength foil (d1) on the cylindrical attachment of the cover, and the holder with polarization filter (e1) on the telescope (see Fig. 6). Turn the holder with polarization filter around the axis of observation until one of the two doublet components disappears, and turn it 90 further until the other component disappears. Fig. 8: Interference pattern for the Zeeman effect in the longitudinal a) observed without quarter-wavelength foil and polarization filter b), c) observed with quarter-wavelength foiland polarization filter to demonstrate counterclockwise and clockwise-circular polarization Additional information The total intensity of all Zeeman components is the same in all spatial directions. In transverse observation, the intensity of the component is equal to the total intensity of the two components. LEYBOLD DIDACTIC GMBH Leyboldstrasse 1 D-50354 Hürth Phone (02233) 604-0 Telefax (02233) 604-222 Telex 17 223 332 LHPCGN D by Leybold Didactic GmbH Printed in the Federal Republic of Germany Technical alterations reserved