Use of Dilatometer in Unusual Difficult Soils a Case Study

Similar documents
Predicting Settlement and Stability of Wet Coal Ash Impoundments using Dilatometer Tests

IN SITU TESTING TECHNOLOGY FOR FOUNDATION & EARTHQUAKE ENGINEERING. Wesley Spang, Ph.D., P.E. AGRA Earth & Environmental, Inc.

Soil type identification and fines content estimation using the Screw Driving Sounding (SDS) data

Boreholes. Implementation. Boring. Boreholes may be excavated by one of these methods: 1. Auger Boring 2. Wash Boring 3.

Chapter 12 Subsurface Exploration

APPENDIX F CORRELATION EQUATIONS. F 1 In-Situ Tests

PROBABILISTIC APPROACH TO DETERMINING SOIL PARAMETERS

5th International Workshop "CPTU and DMT in soft clays and organic soils" Poznan, Poland, Sept , 2014

ScienceDirect. Correlations between cone penetration test and seismic dilatometer Marchetti test with common laboratory investigations

Consolidation lateral stress ratios in clay from flat Dilatometer tests

Determining G-γ Degradation Curve in Cohesive Soils by Dilatometer and in situ Seismic Tests

Interpretation of Flow Parameters from In-Situ Tests (P.W. Mayne, November 2001)

TABLE OF CONTENTS CHAPTER TITLE PAGE TITLE PAGE DECLARATION DEDIDATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK

Cone Penetration Testing in Geotechnical Practice

ISC 5 SELF-BORING PRESSUREMETER TESTS AT THE NATIONAL FIELD TESTING FACILITY, BALLINA 5 9 SEPT 2016

Cone Penetration Test (CPT) Interpretation

ABSTRACT. Use and Application of Piezocone Penetration Testing in Presumpscot Formation

SITE INVESTIGATION 1

Manual on Subsurface Investigations National Highway Institute Publication No. FHWA NHI Federal Highway Administration Washington, DC

Suitability of the SDMT method to assess geotechnical parameters of post-flotation sediments.

LANDSLIDES IN THE WHITE MOUNTAIN (GEOTECHNICAL STUDIES AND ENGINEERING TESTS)

CPT Data Interpretation Theory Manual

Soil Behaviour Type from the CPT: an update

Keywords: CPTu, pore water pressure, liquefaction analysis, Canterbury earthquake sequence

ASSESSMENT OF SHEAR STRENGTH IN SILTY SOILS

IN SITU TESTING IN GEOMECHANICS. Fernando Schnaid Universidade Federal do Rio Grande do Sul

ENCE 3610 Soil Mechanics. Site Exploration and Characterisation Field Exploration Methods

CPT PROFILING AND LABORATORY DATA CORRELATIONS FOR DERIVING OF SELECTED GEOTECHNICAL PARAMETER

Conventional Field Testing & Issues (SPT, CPT, DCPT, Geophysical methods)

LIQUEFACTION ASSESSMENT OF INDUS SANDS USING SHEAR WAVE VELOCITY

Seismic Evaluation of Tailing Storage Facility

Challenges in the Interpretation of the DMT in Tailings

Liquefaction and Foundations

The Ohio Department of Transportation Office of Research & Development Executive Summary Report

(THIS IS ONLY A SAMPLE REPORT OR APPENDIX OFFERED TO THE USERS OF THE COMPUTER PROGRAM

The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally

Use of CPT for design, monitoring, and performance verification of compaction projects

This document downloaded from vulcanhammer.net vulcanhammer.info Chet Aero Marine

CPT Guide 5 th Edition. CPT Applications - Deep Foundations. Gregg Drilling & Testing, Inc. Dr. Peter K. Robertson Webinar # /2/2013

Constitutive Model Input Parameters for Numerical Analyses of Geotechnical Problems: An In-Situ Testing Case Study.

Landslide FE Stability Analysis

EN Eurocode 7. Section 3 Geotechnical Data Section 6 Spread Foundations. Trevor L.L. Orr Trinity College Dublin Ireland.

Engineer. Engineering. Engineering. (in-ja-neer ) A person trained and skilled in any of the various branches of engineering: a civil engineer

Chapter 7 GEOMECHANICS

DERIVATIVE OF STRESS STRAIN, DEVIATORIC STRESS AND UNDRAINED COHESION MODELS BASED ON SOIL MODULUS OF COHESIVE SOILS

Soil Behaviour in Earthquake Geotechnics

SOME OBSERVATIONS RELATED TO LIQUEFACTION SUSCEPTIBILITY OF SILTY SOILS

Geotechnical Indications Of Eastern Bypass Area In Port Harcourt, Niger Delta

CPT: Geopractica Contracting (Pty) Ltd Total depth: m, Date:

Correlations between soil parameters and penetration testing results

Landslide Granice in Zagreb (Croatia)

CPTU crossing existing boreholes in the soil

3. EVOLUTION In 1948 the basic mechanical cone was developed (Figure 1) and this cone is still in use today as the

Seismic piezocone and seismic flat dilatometer tests at Treporti

IAEA SAFETY STANDARDS Geotechnical Aspects of Site Evaluation and Foundations in NPPs, NS-G-3.6

(Refer Slide Time: 02:18)

Collapsible Soils Definitions

(C) Global Journal of Engineering Science and Research Management

PROBLEMS AND SOLUTIONS THAT MAY EMERGE IN THE FOUNDATION AND BODY OF A HOMOGENEOUS FILL DAM ON A WEAK CLAYEY-SILTY-SANDY FORMATION ÇIKRIKÇI DAM

7. Foundation and Slope Stability

Early Applications of DMT in Dubai in Two Main Projects for Natural and Artificial Earthfill Silty Sand

GEOTECHNICAL ENGINEERING II. Subject Code : 06CV64 Internal Assessment Marks : 25 PART A UNIT 1


SOIL MECHANICS AND APPLIED FOUNDATION ENGINEERING FUNDAMENTAL FACTS OF SOIL BEHAVIOR

Minnesota Department of Transportation Geotechnical Section Cone Penetration Test Index Sheet 1.0 (CPT 1.0)

Evaluation of soil liquefaction using the CPT Part 2

DMT Testing for the Estimation of Lateral Earth Pressure in Piedmont Residual Soils

LECTURE NO. 4-5 INTRODUCTION ULTRASONIC * PULSE VELOCITY METHODS

Measuring and comparing soil parameters for a large bridge on East coast of United States

EVALUATION OF STRENGTH OF SOILS AGAINST LIQUEFACTION USING PIEZO DRIVE CONE

GUIDELINE FOR HAND HELD SHEAR VANE TEST

INTRODUCTION TO STATIC ANALYSIS PDPI 2013

Geophysical Site Investigation (Seismic methods) Amit Prashant Indian Institute of Technology Gandhinagar

Vibroflotation Control of Sandy Soils using DMT and CPTU

Liquefaction potential of Rotorua soils

Examples of CPTU results in other soil types. Peat Silt/ clayey sands Mine tailings Underconsolidated clay Other

From - To 0,00-4,90 4,90-6,40 6,40-8,60 8,60-9,60 9,60-10,50 10,50-12,00 12,00-14,80 14,80-15,80 15,80-19,30 19, ,00

CPT Applications - Liquefaction 2

Gotechnical Investigations and Sampling

Comparison of different methods for evaluating the liquefaction potential of sandy soils in Bandar Abbas

SI Planning & Laboratory Testing for Hill-Site Development

Soils. Technical English - I 10 th week

Analysis and measurements of settlement for heavy loaded rigid footing

1.1 Calculation methods of the liquefaction hazard.

SOME GEOTECHNICAL PROPERTIES OF KLANG CLAY

EVALUATION OF DYNAMIC METHODS FOR EARTHWORK ASSESSMENT

Appendix E. Phase 2A Geotechnical Data

Implementation of in-situ and geophysical investigation methods (ERT & MASW) with the purpose to determine 2D profile of landslide

NEW DOWN-HOLE PENETROMETER (DHP-CIGMAT) FOR CONSTRUCTION APPLICATIONS

Determining G-γ decay curves in sand from a Seismic Dilatometer Test (SDMT)

SHEAR STRENGTH OF SOIL

B-1 SURFACE ELEVATION

INVESTIGATION OF SATURATED, SOFT CLAYS UNDER EMBANKMENTS. Zsolt Rémai Budapest University of Technology and Economics Department of Geotechnics

Seismic Design of a Hydraulic Fill Dam by Nonlinear Time History Method

Chapter (12) Instructor : Dr. Jehad Hamad

Theory of Shear Strength

Mechanical Wave Measurements. Electromagnetic Wave Techniques. Geophysical Methods GEOPHYSICAL SITE CHARACTERIZATION. Mechanical Wave Geophysics

Pierce County Department of Planning and Land Services Development Engineering Section

GEOTECHNICAL INVESTIGATION REPORT

THE PREDICTION OF FINAL SETTLEMENT FROM 1D-CONSOLIDATION TEST: A CASE STUDY

Transcription:

Use of Dilatometer in Unusual Difficult Soils a Case Study Mensur Mulabdić University of Osijek, Faculty of Civil Engineering. E-mail: mulabdic@gfos.hr Krunoslav Minažek University of Osijek, Faculty of Civil Engineering. E-mail: krumin@gfos.hr Keywords: loess soil, wetting, settlement, earth dam, in homogeneity, dilatometer test ABSTRACT: Dilatometer tests were performed on two construction sites in eastern Croatia in unusual soils. First site was the building on a hard loess soil that suffered from settlements caused by soil wetting. It was necessary to find out about soil stiffness in order to design soil improvement by use of jet grouting. The second site was an earth dam that had to be checked for in homogeneity in clay fill mechanical properties, in connection with rehabilitation of the dam. In both cases knowledge of soil stiffness was important, and dilatometer tests were performed in addition to other test methods (in situ and laboratory), so that comparison of evaluated value of soil modulus of vertical deformation was possible. Also, hard loess soil required dilatometer blade to be hammered in order to penetrate at certain intervals of depth, which in turn required careful and repeated reparation of the instrument. Despite these difficulties instrument worked well. Comparison of soil parameters evaluated from dilatometer measurements with parameters obtained by other in situ and laboratory tests showed that dilatometer is useful and reliable tool but needs to be checked in unusual soil conditions. Correction coefficients for evaluated soil parameters from dilatometer testing are obtained on some points and were used for improving evaluation of soil parameters on other places. 1 INTRODUCTION Marchetti dilatometer is very useful tool in determination of soil stiffness, and together with piezocone test is very often part of in situ testing program. Usually dilatometer penetration is achieved by pushing force of a drilling rig, with or without pre-boring. But, sometimes it is necessary to hummer the blade (via the drilling rods) to certain depth, either because of insufficient drilling force or due to high soil stiffness. Such operation can damage blade electric connections and requires blade control and reparation. This paper describes use of dilatometer in two projects in Croatia, in different soil conditions, were standard procedure of test performance or test interpretation was not possible. First project is related to high school in Vukovar (eastern part of Croatia), founded on loess soil. Loess material changes its stiffness with water content dramatically - when dry it is very stiff, but when subjected to wetting collapse of its structure occurs. The second project described in this paper was related to the earth dam, were dilatometer tests were conducted in order to get insight in mechanical properties of compacted clay necessary for planning of remediation work for the dam. Both projects were unusual, in terms of performance of test and in terms of test results interpretation. 2 VUKOVAR HIGH SCHOOL BUILDING 2.1 Description of foundation problems A high school building in Vukovar, reconstructed after the 1990 s war destruction, situated on the elevated loess terrain near the Danube river, was suffering from the decline of the bearing capacity of the foundation soil and excessive settlements followed by the formation of cracks within the structure and at its facade. Few years after the war reconstruction (1998), some cracks had been noticed on the building. In the period between 2002-2006 the cracking progressed, regarding both the number and width of cracks throughout the object. The structure was built of massive masonry and was sensitive to settlement. In the early phase of cracking, the settlements of the object were recognized as a main cause for crack formations. The extensive exploratory works, observations and geotechnical measurements on the object and its surroundings were conducted. It

turned out that poorly reconstructed rainfall collecting system caused the wetting of the foundation soil composed mostly of loess (Civil Engineering Faculty in Osijek 1998. and 2007.). 2.2 Exploration works The purpose of the exploration works was to identify the regions affected by yielding and to determine soil properties of the foundation soil to direct the remediation measures. After exploration works were completed, a remediation by jet-grouting method followed. Exploratory borings, dilatometer testing and laboratory investigation works were conducted. Disposition of boreholes, inclinometers and deformeter holes are presented in the Fig. 1. The foundation soil is composed of clay layers in the upper part and loess layers beneath them (the soil profile is shown in the Fig. 6.). Special consideration was given to loess wetting (caused by precipitation water due to a poor rainfall collecting system around the object). The soil profile with the moisture change, observed in the period between the first noticed cracks and time of remediation, has been made. Also the modulus of vertical deformation change with depth has been obtained and then used as the basis for the analysis and modelling of the remediation works. Wetting and softening of the foundation soil did not affect the whole object equally, and the most affected area was the south-eastern part of the object under which several tunnels were positioned (Fig. 1. and Fig. 2.). The tunnel vaults under the building (see the cross-section presented in the Fig. 2.) made of loess became wet because the tunnel served as a drain for the excess water in the soil. Gradually they started to collapse causing the additional soil settlement under the structure. It was therefore decided to fill the tunnels with concrete. In one exploration borehole (named GV-B, Fig. 1.) dilatometer test was employed. Pre-boring was made to the depth of 4 m to get under the foundation base level. Dilatometer measurements were made from the 4,5 m to 13,5 m depth in intervals of 0,5m. The interval of 0,5 m was chosen for practical reasons. The pushing machine didn t have large pushing power (less than 2 t) and pre-boring to clean the borehole above test depth at several intervals was necessary. Three consecutive measurements were made by pushing dilatometer blade (in total depth interval of 1,5 m), then the borehole needed to be cleaned. Dilatometer blade was hammered by vibration of drilling machine rotary head into the soil for the last measurement before cleaning the borehole. After several intervals of hammering, the dilatometer probe needed to be repaired, because electrical contact cable inside the blade detached from its position and needed to be soldered back. The preparation of dilatometer borehole GV-B is shown in Fig. 3. and the dilatometer blade after retrieval from the borehole after measurement is shown at Fig. 4. Dilatometer test results are presented in Table 1 (material index with soil description, dilatometer and constrained modulus, and the friction angle) and in Fig. 5. (material index and constrained modulus). Fig. 1. Disposition of boreholes, inclinometer and deformeter holes, along the area of the building (boreholes: B-1, B-2, B-3, S-1, S-2, IJ-1, IJ-2, IJ-3, deformeters: GV-A, GV-B, GV-D, inclinometers: GV-C, GV-D). The exploration works have revealed the zone of increased moisture content in the soil right beneath the foundation, to the depth between 9 11 meters. This fact provoked collapse of the loess structure, which has been confirmed by the oedometer tests. Fig. 2. Schematic cross-section of high school building with position of collapsed tunnels.

In the same borehole, after reaching depth of 12 m, standard penetration test was made, and also at depths of 16 and 18m. The results from these tests are presented in Table 2. Fig. 3. Preparation of DMT test near high school building. Table 1. Results of Dilatometer tests in borehole GV-B. Depth (m) 4.5 5.0 5.5 6.0 6.5 7.0 8.5 9.0 9.5 10.0 10.5 11.0 12.5 13.0 13.5 Soil description Ed (MPa) 14.9 16.8 12.8 10.6 14.6 11.3 18.6 14.6 13.8 13.5 13.5 21.5 29.1 29.1.0 M (MPa) 16.3 14.8 10.8 9.0 12.4 9.6 15.8 12.4 11.8 11.5 11.5 18.3 24.8 24.8 22.9 Phi (Deg) 32 31 29 26 29 26 26 29 Table 2. Standard penetration test results for borehole GV-B. Depth (m) N(SPT) - uncorrected 12,00 10 16,00 12 18,00 9 Fig. 4. Dilatometer blade after retrieval from borehole of stiff loess. Fig. 5. Dilatometer test results: distribution of material index and constrained modulus with depth. Fig. 6. Soil profile and modulus of vertical deformation.

Dilatometer data, although available from just one borehole, enabled interpretation of soil stiffness at 0,5 m intervals. Very few undisturbed samples from loess soil were taken and tested in oedometer. Comparison of values of the constrained modulus obtained by dilatometer test with oedometer modulus values from other nearby boreholes is presented on Fig. 6. Reasonably good fit of data can be noticed. In terms of soil type identification (Table 1) it can be seen that dilatometer recognized coherent material (ML/CL, Fig. 6.) as y or silty - y soil. If only this description would have been used in designing jet grouting work it would have led to the wrong grouting set up. Therefore, check of dilatometer interpretation with findings from classical drilling records is highly recommended in non-standard soils. It is, however, valuable to point out that dilatometer blade worked very well, despite hammering. There are two ways to perform dilatometer tests with drilling rig of limited pushing force: (1) it is possible to work with pre-drilling for some depth intervals (say 1-1,5 m) and then perform consecutive dilatometer tests over the limited depth interval (say 1-1,2 m), or (2) one can force blade by hammering as long as it progresses. In this latter case one should be aware of need for the blade reparation. Therefore, two blades should be at the site, in order to keep the work going well in time (the authors experienced this at some other projects too, like in the case of testing deposits under one embankment in Eastern Croatia). When undisturbed samples are unavailable, and/or when rig doesn't have enough pushing power, hammering of the dilatometer blade can be performed, under the condition that constant control of blade functionality and integrity of electronics in it is checked. 2.3 Remediation works Based on the analysis of foundation soil and detected damages to the structure it was concluded that remediation of the foundation soil and improvement of the foundation was necessary. That required transmission of the loads form the structure to greater depth to the zone of improved soil. It was achieved by jet-grouting technology, producing firm columns under the foundation in the appropriate disposition. The zone of improvement realised by jet-grouting produced columns of 60 cm in diameter, extended to the depth of 6 or 9 meters under the foundation. The plan view arrangement of jet-grouting columns can be seen in the Fig. 7. The typical jet-grouted column cross-section for foundation underpinning is shown in the Fig. 8. (Mulabdić & Minažek 2009). Fig. 7. Disposition of jet-grouting piles under footings. BASEMENT Fig. 8. Typical cross sections of foundation with pile positioning and dimensions. 3 SMALL EARTH DAM EMBANKMENT- THE SECOND CASE 3.1 Description of foundation problems A small earth dam was built as a part of a future irrigation system. The dam was about 10-meter high at the deepest point in a depression, and was constructed of the clay from its vicinity. During the construction of the dam it was noticed that the construction company didn't fully follow the design requirements and criteria related to zoned construction, replacement of foundation soil and degree of compaction of the lifts of clay. During the filling of the lake, when only few meters of dam slopes were covered with water, problems with

bottom discharge were observed and filling of water had to be stopped. It was decided that the dam should be checked for safety against sliding and deformability, for which geotechnical properties of compacted clay in the dam should have been checked in detail (Mulabdić 2013). 3.2 Testing program The site testing program consisted of drilling of boreholes to get samples for a laboratory testing of the clay, cone penetration testing (CPT) and a dilatometer testing (DMT). The results of analysis of clay properties in the dam based on CPT, DMT and laboratory testing are presented in this section. Boreholes were positioned over the dam body and penetration tests were performed in the crest, see Fig. 9. (Elektroprojekt Zagreb 2010). Four CPT test boreholes and three DMT test boreholes were made. All empirical and theoretical expressions for the interpretation of test results of these two tests are based on natural soils (Larsson & Mulabdic 1991, Lunne et. al. 1996, Marchetti 1980). Therefore it was necessary to check the applicability of standard interpretation methods to compacted clay, for both tests. It should be noted that there is not much experience presented in literature covering CPT and DMT testing in compacted clay. Both tests were conducted according to relevant standards (EN 1997 Part 2:2006). Glycerine was used as fluid in porous stone in CPT cone. 3.3 Soil identification Clay in the embankment was never submerged, except for the part deeper than 9 m measured from the crest. CPT soil type identification was done according to a widely used chart (Robertson, 1990), and in doing so clay of low plasticity was identified in most cases, with some thin layers of silty clay. Pore pressures measured behind the cone (u 2 ) were almost zero, or slightly negative, at all depths. In terms of soil type interpretation, DMT test interpreted clay soil as y-silty to silty-y soil type, with very rare clayey-silty thin layers as it can be seen in Fig. 10. Therefore there were almost no data for undrained strength in DMT interpretation. According to Marchetti (1980), in DMT test for clay soil material index Id it should be 0.1 < Id < 0.6. Since the value of Id in compacted clay of the dam was found to be about or higher than 2 (suggesting a y or y-silty soil type) and there was no in situ pore pressure in soil, it could be concluded that p 0 was too small, due to structure of compacted soil and absence of in situ pore pressures. Fig. 11 shows values of modulus of vertical deformation as interpreted from DMT tests compared to design required values, and undrained shear strength as interpreted from CPT test compared to design required values. Both, CPT and DMT tests detected very pronounced inhomogenity in the clay embankment it seems that almost every lift of compacted clay can be distinguished from the penetration test results. Fig. 9. Position of in situ tests and boreholes on the dam; most important work was done on the crest (line B2-C4). Fig. 10. Distribution of DMT material index and constrained modulus with depth for positions M1 (blue), M2 (green) and M3 (red).

0 Mv (MPa) 0 40 80 120 160 200 1 2 3 4 5 6 7 8 9 Mv DMT M3 Mv CPT C2 Mv lab 10 d (m) Fig. 11. DMT (M1, M2, M3) and CPT tests (C1, C2), over the dam height (cross-section along the crest). 3.4 Modulus of vertical deformation Comparison of modulus of vertical deformation was made for relevant results for oedometer, CPT and DMT test. For CPT it seems that the value of modulus is two times greater than the oedometer modulus, and the values of Mv from DMT test were the highest of these three (Fig. 12.). This might be due to the fact that oedometer tests were performed on submerged specimens, and CPT and DMT tests were performed on clay fill in the embankment that was not submerged. The influence of presence of water on interpretation of DMT test results in terms of modulus Mv was discussed in Mulabdic and Bruncic (2000), for natural soils. They concluded that error in water depth assumption had limited influence on interpreted Mv values. Compacted clay of which the dam was made obviously would be softer if it was submerged. It is difficult to predict soil modulus Mv of a submerged embankment fill from an in situ test performed on a non-submerged embankment fill. Fig. 13. shows that CPT and DMT tests on different locations gave similar mechanical properties of the compacted clay with depth. Fig. 12. Modulus of vertical deformation from oedometer (on submerged specimens), CPT interpretation, compared to DMT standard interpretation values (performed on clay layers that were not submerged). The comparison as shown in Fig. 12 can only be used as a guide for correcting in situ evaluated parameters to laboratory values, but even then correction would not be constant with depth. Tests marked as M1, M2 and M3 (DMT-tests) were performed in one run as standard tests and seismic tests (SDMT), using a seismic probe as described in Cavallaro et al. (2006). Fig. 14. shows shear wave velocities measured in 0,5-meter depth intervals. Since a shear wave velocity is a measure of soil structure and its rigidity, variability of those two parameters should be regarded as a basic indication of the variability of soil mechanical properties. These variabilities are less pronounced in wave velocity diagrams than in CPT and DMT standard diagrams, probably due to difference in depth interval of interpretation: 0,5 m for seismic test compared to depth interval of 0,2 m for static DMT. Although velocities generally increase with depth, there are weaker and stronger intervals at certain depths in M2 and M1 boreholes. The M3 location shows constant increase in shear wave velocity by depth.

0 2 4 6 8 10 12 14 d (m) Mv (MPa) 0 100 200 300 M3 M2 M1 Fig. 13. CPT and DMT tests in cumulative presentation. Fig. 14. Measured shear wave velocity at different SDMT locations, depth intervals 0,5 m. 0 2 4 6 8 10 12 14 d (m) q c [MPa] 0 10 20 C1 C2 Vs (m/s) 0 100 200 300 400 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 M1 6.5 M2 7.0 7.5 M3 8.0 d (m) For a high school foundation improvement, were loess was a foundation soil, insertion of dilatometer blade was difficult because of small pushing power of available boring rig. DMT testing was performed by cleaning the borehole after several measurements and by hammering the dilatometer blade. The blade was repeatedly repaired and used with great confidence. In a case of an earth dam embankment of a poor construction quality, in order to characterize clay fill in the embankment in terms of its physical and mechanical properties, CPT and DMT tests were performed in addition to borings and laboratory testing. The purpose of these two in situ tests was to determine variation of clay properties by depth and at different positions on a dam crest. Based on analyses of in situ and laboratory test results following conclusions can be made: (a) CPT and DMT detected inhomogeneous clay conditions very clearly along the depth, both in static testing and in DMT seismic testing (SDMT), (b) common interpretation of CPT and DMT test results should be used with caution, allowing for appropriate corrections when tests are performed in compacted clays, since they are developed for natural clays, and not for the compacted man made soil; (c) it is of importance for the analysis and characterisation of clay properties whether the embankment is dry or submerged at the time of performing in situ tests; (d) CPT and DMT tests showed remarkable repeatability and proved to be valuable aid in characterizing embankment quality, both in terms of inhomogeinity and physical and mechanical properties; SDMT results also proved to be particularly useful; (e) local correlations between laboratory and in situ test results should always be used, in order to properly account for effects of the presence of water (submerged or non-submerged), specific structure of compacted soil, specific stress distribution and limited experience in using in situ tests for the characterization of compacted soils. 4 CONCLUSIONS The paper presented application of dilatometer testing in difficult / non-standard soils, for two buildings: at one site dilatometer test was a part of investigation program for foundation improvement, and at the other site dilatometer test was used to investigate poor construction quality of an earth dam embankment. Test results from dilatometer testing were compared with test results from laboratory and other in-situ tests (SPT and CPT). 5 REFERENCES Mulabdić, M. and Minažek, K. (2009). Foundation improvement for a building on loess soil. Proceedings of the 17th International Conference on Soil Mechanics and Geotechnical Engineering, Egypt, 2362-2365 Civil Engineering Faculty in Osijek. (1998). High school in Vukovar -Site investigation report. Civil Engineering Faculty in Osijek. (2007). Geotehnical project of remediation of foundation for the building in Vukovar. Mulabdić, M. (2013). Use of penetration testing for determination of soil properties in earth dam.

Proceedings of the 18th International Conference on Soil Mechanics and Geotechnical Engineering, Paris, 595-600. Elektroprojekt Zagreb (2006). Design solution documentation for Opatovac dam. EN 1997-2:2006. Eurocode 7: Geotechnical design - Part 2- Ground investigation and testing. Larsson, R. and Mulabdić, M. (1991). Piezocone tests in clay. Swedish Geotechnical Institute, Report No. 42, Linköping, 240. Lunne, T., Robertson, P.K. and Powell, J.J.M. (1997). Cone Penetration Testing in Geotechnical Practice. E & FN Spon, 312. Marchetti S. (1980), "In Situ Tests by Flat Dilatometer." ASCE Journal GE, Vol. 106, No. 3, March 1980, 299-321. Mulabdić, M. and Brunčić, A. (2000). Prilog analizi primjene dilatometra Marchetti. Građevinar, Vol 52, No. 1, 9-17 (in Croatian). Robertson,P.K. (1990). Soil classification using the cone penetration test. Canadian Geotechnical Journal, (1), 151-158. Cavallaro, A., Grasso, S. and Maugeri, M. (2006). Clay Soil Characterization by the New Seismic Dilatometer Marchetti Test (SDMT). Proc. 2nd international flat dilatometer conference., Washington, 261-267