Tutorials. 1. Autocollimator. Angle Dekkor. General

Similar documents
Auto collimator. Introduction. Objectives: Apparatus: Theory:

Seminar report Autocollimator Submitted in partial fulfillment of the requirement for the award of degree Of Mechanical

Interferometer for Squareness measurement

Unit III Introduction sine bar Sine bar Working principle of sine bar

LINEAR AND ANGULAR MEASUREMENTS

UNIT-II LINEAR AND ANGULAR MEASUREMENTS

LAB 10: OPTICAL MATERIALS AND DISPERSION I

SIR C.R.REDDY COLLEGE OF ENGINEERING ELURU

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

MELOS 530 MEASURING EQUIPMENT FOR LENSES AND OPTICAL SYSTEMS. Combinations and Accessories. Indispensable for Quality Control of Optics

OPERATIONS SUPPLEMENT FOR THE COMPARISON AUTOCOLLIMATOR, D600

Geometric Optics. Scott Freese. Physics 262

IO.5 Elliptically Polarized Light

BHARATHIDASAN ENGINEERING COLLEGE, NATTRAMPALLI. DEPARTMENT OF MECHANICAL ENGINEERING FAQ

Laboratory #29: Spectrometer

Speed of Light in Glass

Polarization of Light and Birefringence of Materials

QUADRANT WITH SPHERICAL LEVEL FOR FIXING THE POSITION IN A BALLOON.

Autocollimators & Accessories. Measuring angle, straightness, flatness, squareness, and parallelism

THE DIFFRACTION GRATING SPECTROMETER

UNIT-5 EM WAVES UNIT-6 RAY OPTICS

Leveling. 3.1 Definitions

GEOMETRICAL OPTICS Practical 1. Part II. OPTICAL SYSTEMS

WATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7

Any first year text, sections on atomic structure, spectral lines and spectrometers

Engineering Physics 1 Prof. G.D. Vermaa Department of Physics Indian Institute of Technology-Roorkee

Introduction. Procedure. In this experiment, you'll use the interferometer to EQUIPMENT NEEDED: Lens 18mm FL. Component holder.

Experiment #4: Optical Spectrometer and the Prism Deviation

Einstein Classes, Unit No. 102, 103, Vardhman Ring Road Plaza, Vikas Puri Extn., Outer Ring Road New Delhi , Ph. : ,

Coherence and width of spectral lines with Michelson interferometer

Dr. Radhakrishnan A N Assistant Professor of Physics GPTC, Vechoochira

Experiment O-2. The Michelson Interferometer

DISPERSION OF A GLASS PRISM

Atomic emission spectra experiment

Engineering Metrology

FUNDAMENTALS OF DIMENSIONAL METROLOGY

An accessory to the polarizing microscope for the optical examination of crystals.

IMPROVING BEAM QUALITY NEW TELESCOPE ALIGNMENT PROCEDURE

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

'AD-AIIO 927 ARMY ENGINEER TOPOGRAPHIC LABS FORT BELVOIR VA PIG 13/13 MEASURING TILT WITH AN AUTOMATIC LEVEL,CU; FEB AZ K 0 ROBERTSON

ADAS Guide to choosing the right Telescope. Produced by Members of the Society, Nov 2017

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student

Read the following BEFORE getting started:

PFIS Camera and Collimator CDR Conceptual Design Report. March 5, 2003 J. Alan Schier

Physics 313: Laboratory 8 - Polarization of Light Electric Fields

Larbert High School. Quanta and Waves. Homework Exercises ADVANCED HIGHER PHYSICS

Physics 319 Laboratory: Basics of telescopes and Microscopes (Magnification Experiment) and transverse magnification, M t

Dispersion and resolving power of the prism and grating spectroscope (Item No.: P )

Experiment 2: The Speed of Light

DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Sub Code/Name: ME 1304/Engineering Metrology & Measurements Year/Sem :III/ V UNIT-I

Chapter Ray Optics and Optical Instrument

LIGHT. A beam is made up of several rays. It maybe parallel, diverging (spreading out) or converging (getting narrower). Parallel Diverging Converging

REFLECTION AND REFRACTION

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

Seminar BELA STAR SIMULATOR

Physics 476LW Advanced Physics Laboratory Michelson Interferometer

Optical Instruments. Chapter 25. Simple Magnifier. Clicker 1. The Size of a Magnified Image. Angular Magnification 4/12/2011

CIV : THEODOLITE ADJUSTMENT

OPTICAL INSTRUMENTS VERY SHORT ANSWER QUESTIONS

Picometre metrology. The Gaia mission will create an ultra-precise three-dimensional map of about one billion stars

PHYS 102 Exams. PHYS 102 Exam 3 PRINT (A)

The Quantum Model of the Hydrogen Atom

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION

Instruments and Related Topics

Engineering Physics 1 Prof. G.D. Varma Department of Physics Indian Institute of Technology-Roorkee

Lecture 2: Basic Astronomical Optics. Prisms, Lenses, and Mirrors

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

NEW STANDARD SEXTANT OF THE U. S. NAVY

Chapter 2. Altitude Measurement

αx = arctan( x ) x αy = arctan( y ) y INTR ODUCTION f f a = f 2 +z f z f f α 3/300 rad = rad = 0,5730 =

Homogeneity of optical glass

Mandatory Assignment 2013 INF-GEO4310

LAB DEMONSTRATION OF INTERFEROMETRIC

School. Team Number. Optics

Michelson Interferometer

ilearnalignment Alignment Training Subjects

Interferometers. PART 1: Michelson Interferometer The Michelson interferometer is one of the most useful of all optical instru

ARC SPECTRUM OF IRON /COPPER / BRASS

Experiment 3 The Simple Magnifier, Microscope, and Telescope

SCHIEBER TELESCOPES. Unique, High-Quality Telescopes

ABOUT SPOTTINGSCOPES Background on Telescopes

Directions for use

BD-04a: Check Machine Geometry and Lost Motion

A Question. Simple Magnifier. Magnification by a Lens 11/29/2011. The last lecture

The Michelson Interferometer

Atomic and nuclear physics

Illuminated Reticle Technologies for Rifle Scopes. Illuminated Reticle Technologies for Riflescopes

Magnifying Glass. Angular magnification (m): 25 cm/f < m < 25cm/f + 1. image at 25 cm (= normal near point) relaxed eye, image at (normal) far point

Electrostatic and Magnetic Deflection of Electrons in a Cathode Ray Tube

Liquid refractometer based on immersion diffractometry

The Treptow Giant Telescope in Berlin is the longest moveable refracting telescope on Earth. Some of its properties are summarised below:

custom reticle solutions

Michelson Interferometer. crucial role in Einstein s development of the Special Theory of Relativity.

Determination of Cauchy s Contants

KCSE 2009 PHYSICS PAPER 2

DHANALAKSHMI COLLEGE OF ENGINEERING. (Dr.VPR Nagar, Manimangalam, Tambaram) Chennai

HERSCHEL/UVCI ALIGNMENT PLAN

To determine the wavelengths of light emitted by a mercury vapour lamp by using a diffraction grating.

Using the Spectrometer

5 TH ERMAL GRADIENT INTERFEROMETRIC MEASUREMENT

Transcription:

Tutorials 1. Autocollimator General An autocollimator is a Precise Optical Instrument for measurement of small angle deviations with very high sensitivity. Autocollimator is essentially an infinity telescope and a collimator combined into one instrument. A n autocollimator has a wide variety of applications including precision alignment, detection of angular movement, verification of angle standards, and angular monitoring of machine bed movements. In engineering applications, the most common requirement is the measurement, of-geometrical parameters such as alignment, straightness, squareness, flatness, etc. e.g., in a lathe it is desired that tool must move in a straight path to generate perfect cylinder and it is possible.only when the controlling guideways are themselves straight. The auto- collimator has a built-in target that is projected by collimated light beams. A Plane reflector placed normal to the collimated beam reflects the target and the image is observed in the Eyepiece of the instrument. The Autocollimator is placed outside the Machine bed approx 0.5m away and a reflector is placed on the machine bed. The movement of the reflector along the bed will cause the reflected image of the target to shift if the bed is not plane and has ups and down errors. Angle Dekkor In this system, an illuminated scale is set in the focal plane of the collimating lens outside the field of view of a microscope eyepiece. It is then projected as a parallel beam and strikes a plane reflector below the instrument. It is reflected, and refocused by the lens so that its image is in the field of view of the eyepiece. The image falls, not across a simple datum line, but across a similar fixed scale at right angles to the illuminated image. Thus, the reading on the illuminated scale measures angular deviations from one axis at 90 to the optical axis, and the reading on the fixed scale gives the deviation about an axis mutually at right angles to the other two. This feature enables angular errors in two planes to be dealt with or more important, to ensure that the reading on a setting master and on the work is the same in one plane, the error being read in the other. Thus, induced compound angle errors are avoided. The setup consists of a lapped flat and reflective base above which the optical details are mounted in a tube on an adjustable bracket. In use, a master, either a sine bar or a group of combination angle gauges is set up on the base plate and the instrument is adjusted until a reading on both sides is obtained. It is now replaced by the work, a gauge block to give a good reflective surface being placed on the face to be checked. The gauge block can usefully be held in place with elastic bands. The work is now slowly rotated until the illuminated scale moves across the fixed scale, and is adjusted until the fixed scale reading is the same as on the setting gauge. The error in the work angle is the difference in the two readings on the illuminated scale.

Principle An Autocollimator is basically a telescope, permanently focused at infinity. The basic function of an autocollimator is to detect and measure a deviation in the position of a reference reflective surface. A cross line Reticule "A" is placed at the principal focus of a collimating lens. The Lens collimates the Reticule image and travels as a parallel beam of light. When a plane reflector is placed normal to the optical axis of the collimated beam, it will be reflected back along its own path and focused at the same point. If the plane reflector be now tilted through a small angle θ, then parallel beam will be deflected through twice this angle, and will be brought to focus at a different point "B" in the same plane at a distance X from O. Then AB = 2 x Tan θ/ f, where f is the focal length of the lens. An illuminated Cross Line Target reticule placed at the focus of the Objective collimating lens is projected after reflection from a beam splitter. A Plane reflector placed normal to the optical axis of parallel beam in front of the objective Lens returns the beam along their original paths. A portion of the returned light passes straight through the beam splitter and the return image of the target cross line is viewed through an Eyepiece.

The Eyepiece is provided with a measuring Graticule. The reflected Image of the Target cross line is brought to focus in the plane of the Eyepiece graticule and exactly coincident with its intersection. If the reflector is tilted through a small angle the reflected light beam will be brought to focus in the plane of the Eyepiece Reticule but linearly displaced by an amount 2Tan θ x f. Linear displacement of the reticule image in the plane of the eyepiece is therefore directly proportional to reflector tilt and can be measured by an eyepiece reticule or an optical micrometer system. The focal length determines basic sensitivity and angular measuring range. The longer the focal length the larger is the linear displacement for a given reflector tilt. The maximum working distance is the separation between reflector and autocollimator and is governed by the effective diameter of the objective lens. At long working distances the angular measuring range of the instrument reduces. Large size reflectors are required atleast equal to the diameter of the Objective lens to have better image contrast. Construction

Applications a) Straightness For Straightness measurement a reflector is either moved along the surface or mounted on a sliding carriage part of the machine to be measured. The mirror base length is usually 100 mm and could differ. Deviations from straightness will result in tilt of the mirror. Deviation from straightness are given by: h = Tan theta b, where theta = reflector tilt, b = base length At each position of the reflector in defined steps of the sliding carriage, the deflected image position of the target with respect to the stationary eyepiece reticule in vertical and the horizontal directions can be measured by the autocollimator. b) Flatness Machine Bed Flatness measurement Flatness measurement of a surface table require measurement of deviation from straightness in two directions. The reflector is moved along the surface to be measured. Along each line a straightness measurement is carried out. The data from surface generators lines are used to calculate the shape of the surface and the deviations from flatness.

Surface Table Flatness Measurements Additionally two reflectors may be required to keep the Autocollimator position the same for both x & Y straightness measurements. In place of reflector a Penta Prism could also be used. If only one additional reflector is used, then the Autocollimator position should be altered. c) Parallel Alignment of Rolls

d) Squareness For squareness measurement, the Autocollimator should be set in line with the Machine bed. The procedure is similar with straightness measurement. A reflector is placed on the bed and the Autocollimator is placed away from the machine bed and set as a reference. An accurate pentaprism is placed very close to the vertical column used to transfer the autocollimator beam to the second surface. The straightness of the second surface is measured. The data are then combined and corrected for the error of the pentaprism e) Rotary Indexing A reflecting polygon is put on rotary table or dividing head under test. One side of the polygon is squared to the optical axis of the autocollimator. The rotary table is set on zero. The rotary table with the polygon is rotated until next polygon side is square to autocollimator. The graduation of the table is compared with the expected angle. Sighting Aid This accessory is used when Autocollimator is used for inspection of long size bed straightness measurements. The Reflector/Mirror need to be aligned perpendicular to the axis of Autocollimator. There could be difficulty in locating the reflector when using for long distance. Through sighting aid you would observe two images, one from the Autocollimator and the other after reflection from the Mirror. The Reflector is tilted until the two images coincide. Once this adjustment is made, the Autocollimator would receive the image after reflection from the Mirror.

Position of Reflector for straightness measurement. If the reflector is not positioned properly, the reflector may not reflect the beam back to the Autocollimator. The Sketch shown below is self explanatory for the reflection positioning.

Applications in Optics Industry a) Wedge Measurement of wedge and deflection angle The parallel beam emerging from autocollimator is reflected from both surfaces of the wedge. The wedge angle _ is given by: where: d-displacement of the reflected image n-refractive index of glass f-focal length of the autocollimator For fast measurement in optical manufacturing, the displacement d for a given angle tolerance and focal length f can be calculated and transferred to the illuminated reticule in form of a pinhole, so that the ascertainment of the component can be made on a go and no go basis: b) Right Angle Prism Internal angle of 90 prisms The reflected images from the 90 sides (which are insensitive against rotation around the roof edge) are displaced by an amount x, if a deviation from 90 angle _ is present. A presence of a displacement in height by the amount y proves a pyramid error _ as well: n-refractive index of glass f-focal length of the autocollimator Alpha = X/4nf Gamma = y 4nf c) 45 deg Prism a) Relative measurement of 45 -angle To measure the 45 angle a master prism is used. Both prisms are put on an accurate flat. The 90 angle of the prism under test must be checked first, since the error of this angle will influence the measurement. b) Absolute measurement of 45 -angle. The Autocollimator is directed on one side of the 90 -angle. Two images will be produced from both sides of the prism. The internal reflection within the prism will produce a displacement d depending on the error of the 45 angle where _ is the error of 90 angle. d) External 90 deg The 90 prism is put on a accurate flat surface. The emerging beam of autocollimator is reflected on the prism side and flat and returns along the original path if the angle is exactly 90. No displacement appears in the eyepiece. Deviations from 90 can be measured in the eyepiece. The error size: where f= focal length of autocollimator. The sign -/+ of the error is determined by defocusing the eyepiece: moving the focal plane of the eyepiece towards objective lens, a negative error results if the distance d becomes smaller. e) Penta Prism

The autocollimator is mounted on an adjustable stand and can be tilted at any angle. A master prism is used to align the autocollimator to the mirror. The master prism is replaced by the prism under test and the angle difference is read off through the eyepiece. Example: Measurement of deviation angle through pentaprisms.