tel.: , fax: , mobile:

Size: px
Start display at page:

Download "tel.: , fax: , mobile:"

Transcription

1 EFFECTIVENESS IS OUR GOAL. In order to achieve that, we have developed an entire range of photoluminescent products, of various parameters and applications, serving for the effective marking of evacuation routes and the location of fire-fighting equipment. In terms of their photometric parameters, these products might be divided into the three basic groups: SL/2 they meet with a substantial surplus the requirements of the norms: PN/92/01,02,04 and also in the norm: DIN They are intended to be used for the marking of premises, both well-lighted and with the average level of glowing. SL/5 are intended to be used for the marking of premises lighted at certain times or very poorly (hospitals, clinics, warehouses, hotel corridors, underground passages, for constructing the Low Location Lighting LLL and also for the marking of ships, also including building LLL systems). SL/8 are intended to be used for marking in special conditions. Apart from very high photometric parameters, they meet high requirements relevant to: surface inflammability and toxic properties. They are installed on non-inflammable foundations with the intention to be used for marking: on ships, in the tunnels of the underground railway, underground passages and for the needs of the military to be used in the conditions of even very poor activated lighting. SIGNS SL/2 material luminance after the passage of time (mcd/m 2 ) 2 min. 5 min. 10 min. 30 min. 60 min. 120 min. the loss of light time (min.) Film (F) Board (P) 513,71 209,71 106,31 33,51 15,31 6, Polycarbonate (W) 525,71 229,71 116,51 35,81 16,11 7, System TD (T) 342,81 149,01 76,38 23,81 10,79 4, SIGNS SL/5 material luminance after the passage of time (mcd/m 2 ) 2 min. 5 min. 10 min. 30 min. 60 min. 120 min. the loss of light time (min.) Film (F) Board (P) 682,70 279,70 140,90 43,70 19,70 8, Polycarbonate (W) 650,71 270,71 134,91 41,61 18,71 8, System TD (T) 478,71 194,71 97,51 29,91 13,39 5, Aluminium (ALU) 951,23 394,23 195,23 58,23 26,03 11, SIGNS SL/8 luminance after the passage of time (mcd/m 2 ) the loss of light material 2 min. 5 min. 10 min. 30 min. 60 min. 120 min. time (min.) Aluminium (ALU) 1486,2 638,23 319,23 96,23 42,03 17, THE POLISH NORM: PN - 92/N /01 luminance after the passage of time (mcd/m 2 ) the loss of light 2 min. 5 min. 10 min. 30 min. 60 min. 120 min. time (min.) , THE NORM: DIN luminance after the passage of time (mcd/m 2 ) the loss of light 2 min. 5 min. 10 min. 30 min. 60 min. 120 min. time (min.) , THE NORM: ISO / FDIS luminance after the passage of time (mcd/m 2 ) class 2 min. 5 min. 10 min. 30 min. 60 min. 120 min A B C D

2 Board PCV p Board PCV SL/2 Light luminance (mcd/m²) 513,7 209,7 106,3 33,5 15,3 6, min. the time after the passage of which light luminance Material of lower ignition propensity (the measurement of a Inflammability: sample of material in aluminium, in accordance with the norm: ISO 3795) -20 C up to +70 C The kind of used glue: Acrylic glue FTM 1 Peel strength: 30 N / 25 mm (180 on stainless steel) The temperature of storage: 15 C up to 25 C, relative humidity 50% Obtained certificates, undergone tests and the received certificates of attestation: clean, dry, free of dusts and degreased. Application on materials having low surface tension such as: polypropylene or polyethylene ought to be avoided. Fitting on significantly curved surfaces having small diameters ought to be avoided. The temperature of fitting higher than +10 C. tdc SL/2 ; June 2005 Board PCV SL/5 Light luminance (mcd/m²) 682,7 279,7 140,9 43,7 19,7 8, min. the time after the passage of which light luminance The classification of inflammability: Maximum final adhesivity: Obtained certificates, undergone tests and the received certificates of attestation. This material meets the requirements of the international Code of FTP / part 5 in the scope of surface inflammability. Report: TZ / FTP-5 / 106 / This material meets the requirements of the international Code of FTP/part 2 in the scope of the toxic properties of the products of combustion. Report: TZ / FTP-2 / 124 / From -40 C up to +90 C The signs are provided with the self-adhesive points of fitting. +18 C. After 24 hours tdc SL/5

3 Film f Film SL/2 Light luminance (mcd/m²) 513,7 209,7 106,3 33,5 15,3 6, min. the time after the passage of which light luminance Material of lower ignition propensity (the measurement of Inflammability: a sample of material in aluminium, in accordance with the norm: ISO 3795) From -20 C up to +70 C The kind of used glue: Acrylic glue FTM 1 Peel strength: 30 N / 25 mm (180 on stainless steel) The temperature of storage: 15 C do 25 C, relative humidity 50%. Film SL/5 having small diameters ought to be avoided. The temperature of fitting higher than +10 C. tdc SL/2, June 2005 Light luminance (mcd/m²) 682,7 279,7 140,9 43,7 19,7 8, min. - the time after the passage of which light luminance Material of lower ignition propensity (the measurement of Inflammability: a sample of material in aluminium, in accordance with the norm: ISO 3795) From -20 C up to +70 C The kind of used glue: Acrylic glue FTM 1 Peel strength: 30 N / 25 mm (180 on stainless steel) Material of lower ignition propensity (the measurement of Inflammability: a sample of material in aluminium, in accordance with the norm: ISO 3795) having small diameters ought to be avoided. The temperature of fitting higher than +10 C. tdc SL/5

4 SYSTEM TD t SYSTEM TD SL/2 Light luminance (mcd/m²) 342,8 149,0 76,3 23,8 10,7 4, min. - the time after the passage of which light luminance From - 40 C up to + 90 C The kind of used glue: Acrylic glue for double-side application on a foundation of polyethylene foam. Off-steel shear strength: 40 N / 625 mm² (in accordance with norm EN 1943, at the temperature of 23 C +/-2 C). +18 C. tdc SL/2, June 2005 SYSTEM TD SL/5 Light luminance (mcd/m 2 ) 478,7 194,7 97,5 29,9 13,3 5, min. - the time after the passage of which light luminance From - 40 C up to + 90 C The kind of used glue: Acrylic glue for double-side application on a foundation of polyethylene foam. Off-steel shear strength: 40 N / 625 mm² (in accordance with norm EN 1943, at the temperature of 23 C +/-2 C). Off-steel peel strength: 22 N / 25 mm (in accordance with norm EN 1939, at the temperature of 23 C +/-2 C). +18 C. tdc SL/5

5 Polycarbonate SL / 2 w Polycarbonate SL/2 Light luminance (mcd/m²) 525,71 229,71 116,51 35,81 16,11 7, min the time after the passage of which light luminance Photoluminescent signs and on-the-floor sequences - Name System LLL. Type Manufacturer: Intended use: Light luminance: The kind of used glue: Off-steel shear strength: Off-steel peel strength: Maximum final adhesivity: Remarks about operation: PC - SL/2 On-the-floor signs and sequences serve for the marking, at a low level, of evacuation routes, and also dangerously protruding thresholds, the elements of constructions and parts of machines in long corridors, on stairs etc. A calibration certificate: 2500-M M23 // 2004 Central Office of Measurements in Warsaw. From -40 C up to +120 C Acrylic glue 40 N / 625 mm² 22 N / 25 mm After 24 hours +10 C. The recommended temperature of fitting between 15 C up to 20 C. On-the-floor signs and sequences, once pasted on, are unfit to be used again after peeling off. tdc SL/2 DNV 0575, June 2005

6 Polycarbonate SL / 5 w Polycarbonate SL/5 Light luminance (mcd/m²) 650,71 270,71 134,91 41,61 18,71 8, min the time after the passage of which light luminance Name Photoluminescent signs and on-the-floor sequences - System LLL Type PC - SL / 5 Manufacturer: On-the-floor signs and sequences serve for the marking, Intended use: at a low level, of evacuation routes, and also dangerously protruding thresholds, the elements of constructions and parts of machines in long corridors, on stairs etc. Light luminance: A calibration certificate: 2500-M M23 // 2004 Central Office of Measurements in Warsaw. -40 C do +120 C The kind of used glue: Acrylic glue Off-steel shear strength: 40 N / 625 mm² Off-steel peel strength: 22 N / 25 mm Remarks about operation: 10 C. The recommended temperature of fitting between 15 C and 20 C. On-the-floor signs and sequences, once pasted on, are unfit to be used again after peeling off. tdc SL/5 DNV 0575 CNBOP No.:... Year, June 2005

7 Thermoplastic material m Manufacturer: Intended use: Wykonanie: The manner The conditions Lighting parameters: Remarks about operation: Chwaszczyno Oliwska 166 A photoluminescent convex floor marker, which is intended for the permanent marking of the shoulder of an evacuation route at a low level on the premises such, as: production halls, warehouses, garages, underground passages, stairs, etc., and also on foundations of open-work structure (greting). The marker is manufactured of thermoplastic plastic. The marker is provided with a threaded mandrel, serving for fitting on open-work structures or platforms, by means of screwing with nut of a special cushion, which might be added to the marker. In case of fitting on a monolithic surface, fitting is performed with the use of plastic wall plug or with the of glues commonly applied in the building industry. Fitting ought to be performed after the previous drying of the surface and removing dust from it. The product is manufactured solely with the use of SL / 5 technology (measured in accordance with DIN ). From -40 C up to +90 C The marker is resistant to mechanical loads and shearing. The maintenance and cleaning of surfaces ought to be conducted with the use commonly used washing and cleaning agents. Caution! In the luminescent part of the marker, fighter spots might be observed these are the agglomerations of pigment, which, however, do not change the properties of the entire product, nor do they exert an adverse influence upon the parameters of it.

8 Aluminium material a ALUMINIUM SL/5 Light luminance (mcd/m²) 951,2 394,2 195,2 58,2 26,0 11, min the time after the passage of which light luminance Non-toxic. A certificate of hygienic attestation (HK / B/0025 / 01 / 2005) from the National Not found to be radioactive. An assessment: Z-II / 002 / from the Central Laboratory for Radiological Protection in Warsaw. The classification of inflammability: This material meets the requirements of the international Code of FTP/part 5 in the scope Klasyfikacja palności: of surface inflammability. Report: TZ / FTP-5 / 106 / 2004 Smoke emission properties and toxic properties: This material meets the requirements of the international Code of FTP/part 5 in the scope of the toxic properties of the products of combustion. Report: TZ / FTP-2 / 125 / 2004 From - 40 C up to +100 C tdc ALU - SL / 5, June 2005 ALUMINIUM SL/8 Light luminance (mcd/m²) 1486,2 638,2 319,2 96,2 42,0 17, min the time after the passage of which light luminance Non-toxic. A certificate of hygienic attestation (HK / B / 0025 / 01 / 2005) from the National Not found to be radioactive. An assessment (Z-II / 003 / ) from the Central Laboratory for Radiological Protection in Warsaw. The classification of inflammability: Smoke emission and toxic properties: This material meets the requirements of the international Code of FTP/part 5 in the scope of surface inflammability. Report: TZ / FTP-5 / 123 / 2004 This material meets the requirements of the international Code of FTP/part 5 in the scope of the toxic properties of the products of combustion. Report: TZ / FTP-2 / 125 / 2004 From -40 C up to +100 C tdc ALU - SL / 8

SWARCO LIMBURGER LACKFABRIK GmbH Road Marking Systems. 1-component Afterglow paint system TECHNICAL INFORMATION

SWARCO LIMBURGER LACKFABRIK GmbH Road Marking Systems. 1-component Afterglow paint system TECHNICAL INFORMATION 1-component Afterglow paint system TECHNICAL INFORMATION 1-component Afterglow paint system Art.-No.: 8129016 white, 1-comp. Afterglow primer Art.-No.: 8121111 yellow-green, 1-comp. Afterglow paint Art.-No.:

More information

Chartered Institute of Building Service Engineers (CIBSE) code for interior lighting design

Chartered Institute of Building Service Engineers (CIBSE) code for interior lighting design Chartered Institute of Building Service Engineers (CIBSE) code for interior lighting design The maintenance factor gives an estimate of how lighting conditions will deteriorate through everyday use. Dust

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

1 Product description. Material. 3 Warnings for intended use. Instructions for use ept.i.p.s. Version B. English (EN)

1 Product description. Material. 3 Warnings for intended use. Instructions for use ept.i.p.s. Version B. English (EN) Instructions ept.i.p.s. see Fig. Tab. p. p. for Version use B 1 Product description The pipette tips ept.i.p.s. are single-use pipette tips for aspirating and dispensing liquids with air cushion pipettes.

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

Why we will apply Phosphorescent Pigment from NIC. Make safe and recycling-oriented society by using Phosphorescent Pigment

Why we will apply Phosphorescent Pigment from NIC. Make safe and recycling-oriented society by using Phosphorescent Pigment Why we will apply Phosphorescent Pigment from NIC Make safe and recycling-oriented society by using Phosphorescent Pigment What is Phosphorescent Pigment? What is Phosphorescent Pigment? The substance

More information

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying with the European standard EN. EUROBATEX is a closed

More information

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting Whitepaper_ WP_T_Non-Contacting_Temperature_Measurement ABB temperature measurement Radiation thermometry Measurement made easy Process temperature measurement practice--non-contacting By Gary Freeman,

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013 industry hall Customer : Processed by : Siteco Light Consulting Project description: spatial geometry (L*W*H): 54,00m*21,00m*9m reflection values (C*W*F): 70*50*20 maintenance factor: 0,67 user surface

More information

EOSMS Guidelines Date: 01/16/2014 Page 1 of 5

EOSMS Guidelines Date: 01/16/2014 Page 1 of 5 EOSMS Guidelines Date: 01/16/2014 Page 1 of 5 Introduction The Department of Environmental Health, Safety has developed generic standard operating procedures relevant to safety and health considerations

More information

BUS5 Building structures 5: Fire safety

BUS5 Building structures 5: Fire safety Czech Technical University in Prague FACULTY OF CIVIL ENGINEERING Deptarment of Building Structures BUS5 Building structures 5: Fire safety Excercise 2 Fire Compartments, Fire Risk, Fire Resistance Grades

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

ept.i.p.s. pipette tips are available with various degrees of purity, with and without filters, and as special tips.

ept.i.p.s. pipette tips are available with various degrees of purity, with and without filters, and as special tips. Instructions ept.i.p.s. see Fig. Tab. p. p. for General use Lab Product 1 Product description The pipette tips are single-use pipette tips for aspirating and dispensing liquids with air cushion pipettes.

More information

Chemical Safety. Rami E. Kremesti M.Sc.

Chemical Safety. Rami E. Kremesti M.Sc. Chemical Safety Rami E. Kremesti M.Sc. The Need for Chemicals Fuel Cleaning Personal Hygiene ph control Biocides/Disinfection Packaging Pharmaceuticals Water Treatment Corrosion Control Machine Lubrication

More information

@Copyright 2016 SKAPS Industries.

@Copyright 2016 SKAPS Industries. SKAPS INDUSTRIES 571 Industrial Pkwy, Commerce, GA 30529 Phone: (706) 336 7000 Fax: (706) 336 7007 E Mail: contact@skaps.com SKAPS GEOCOMPOSITE DROP IN SPECIFICATIONS @Copyright 2016 SKAPS Industries www.skaps.com

More information

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm VENETIAN SL27C SL32C BLIND english Technical Catalogue double-glazed unit 27 mm 32 mm dimensions technical specification SL27C SL32C System C C SL27C VENETIAN SL32C BLIND The venetian blinds SL27C and

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

Safety Data Sheet. Identification of the substance/mixture, intended use and of the company/undertaking

Safety Data Sheet. Identification of the substance/mixture, intended use and of the company/undertaking http://www.clickchemistrytools.com E: inquiries@clickchemistrytools.com T: 480 584 3340 F: 866 717 2037 Safety Data Sheet Section 1: Identification of the substance/mixture, intended use and of the company/undertaking

More information

Thermometers. Applications

Thermometers. Applications 92 Temperature Thermometers Thermometers On the next pages you will find a broad range of thermometers with fixed probes or exchangeable probes with rigid probes or probes with cable and hand grip. The

More information

N) manual. Biomaster Operating manual

N) manual. Biomaster Operating manual 830 ual N) manual Operating manual Copyright 2013 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior permission of the copyright owner. Trademarks Eppendorf and the

More information

AO291 Issue date: Product Data FASSON Transfer Polyimide Matt White TC11 / S8088 / BG50 Wh

AO291 Issue date: Product Data FASSON Transfer Polyimide Matt White TC11 / S8088 / BG50 Wh FASSON Transfer Polyimide Matt White TC11 / S8088 / BG50 Wh Facestock A matt white topcoated polyimide film with very high dimensional stability, heat and chemical. The high opacity white topcoat is specifically

More information

Technical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS

Technical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS CONCRETE / SOLID STONE USAGE 1. AREAS OF APPLICATION Heavy load-carrying attachments in solid stone, concrete, porous concrete and light concrete Suitable for attachment points close to the edge, since

More information

Positive Signal The most technologically advanced. double coated dichroic filters are used, which transmit

Positive Signal The most technologically advanced. double coated dichroic filters are used, which transmit The PAPI (Precision Approach Path Indicator) system is a simple and efficient, positive visual aid to the pilot on final approach. The PAPI system consists of a line of four units at 90 to the runway center

More information

8.6 Product data sheet

8.6 Product data sheet Schlüter -KERDI-SHOWER Drainage floor level showers 8.6 Product data sheet Application and Function Schlüter -KERDI-SHOWER is a modular system for the construction of floor level showers with ceramic tiles.

More information

Safety Data Sheets (SDS)

Safety Data Sheets (SDS) Safety Data Sheets (SDS) The following content is taken directly from the Government s Occupational Health and Safety Administration (OSHA) website. The following is a description of what a proper SDS

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

Collective Road Lighting class ME 5

Collective Road Lighting class ME 5 Collective Road Lighting class ME 5 Customer : Processed by : Siteco Light Consulting Project description: Collective Road_Lighting class ME5 according to DIN EN 13201 Luminaire: Streetlight 10 Mini Basic

More information

Introduction Wood K plus. Motivation. Results. Conclusions. J. Leßlhumer 1, J. Sinic 1, M. Reif 1, A. Haider 1, D. Cascorbi 2

Introduction Wood K plus. Motivation. Results. Conclusions. J. Leßlhumer 1, J. Sinic 1, M. Reif 1, A. Haider 1, D. Cascorbi 2 1 st Workshop - Basics for Chemistry of Wood Surface Modification April 25-26, 2012, Kuchl/Salzburg, Austria Surface modification of WPC products to improve bonding strength J. Leßlhumer 1, J. Sinic 1,

More information

SAFETY TRAINING LEAFLET 08 ACETYLENE, CALCIUM CARBIDE, LIME SLUDGE AND PURIFYING MATERIALS

SAFETY TRAINING LEAFLET 08 ACETYLENE, CALCIUM CARBIDE, LIME SLUDGE AND PURIFYING MATERIALS SAFETY TRAINING LEAFLET 08 ACETYLENE, CALCIUM CARBIDE, LIME SLUDGE AND PURIFYING MATERIALS Doc 23.08/18 EUROPEAN INDUSTRIAL GASES ASSOCIATION AISBL AVENUE DES ARTS 3-5 B 1210 BRUSSELS Tel: +32 2 217 70

More information

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial

More information

Safety Data Sheet. 1. Identification of the Substance/Mixture and the Supplier. 2. Hazards Identification

Safety Data Sheet. 1. Identification of the Substance/Mixture and the Supplier. 2. Hazards Identification Safety Data Sheet 1. Identification of the Substance/Mixture and the Supplier Supplier : National Institute of Advanced Industrial Science and Technology (AIST) Address : 1-3-1 Kasumigaseki, Chiyoda, Tokyo,

More information

Safety Data Sheet. 1. Identification of the Substance/Mixture and of the Supplier. 2. Hazards Identification

Safety Data Sheet. 1. Identification of the Substance/Mixture and of the Supplier. 2. Hazards Identification Safety Data Sheet 1. Identification of the Substance/Mixture and of the Supplier Supplier : National Institute of Advanced Industrial Science and Technology (AIST) Address : 1-3-1 Kasumigaseki, Chiyoda,

More information

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed

More information

FIS Specifications for Flex Poles (Edition May 2008) Original Text: German

FIS Specifications for Flex Poles (Edition May 2008) Original Text: German FIS Specifications for Flex Poles (Edition May 2008) Original Text: German 1 Field of Application and Basic Information The following FIS specifications for flex poles are intended to ensure that flex

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

How to Determine the Long-Term Performance of Vacuum Insulation Panels

How to Determine the Long-Term Performance of Vacuum Insulation Panels How to Determine the Long-Term Performance of Vacuum Insulation Panels Roland Caps Board Member of VIPA Chief Research Officer and Founder of va-q-tec AG QUALICHeCK Workshop Brussels, 15 Dec. 2016 Vacuum

More information

CS Series. Capacitance Type. Type. Proximity Sensor. Features

CS Series. Capacitance Type. Type. Proximity Sensor. Features INFORMATI Series Features Capacitance Type - Metal cylinder/resin cylinder/square type - Non-metal objects such as wood, paper, plastic and water can be detected. - The operating distance is adjustable

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

LED light engine / OLED LED compact. Umodule STARK DLE CLASSIC STARK DLE 82,8 54,4. Ordering data

LED light engine / OLED LED compact. Umodule STARK DLE CLASSIC STARK DLE 82,8 54,4. Ordering data Product description Downlights High-flux LED module Low tolerances for colour temperatures (MacAdams 4) Compact design Excellent thermal management 1 NTC for temperature control High-power LED module in

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

Changes to Materials Data Safety Sheets (MSDS)

Changes to Materials Data Safety Sheets (MSDS) Changes to Materials Data Safety Sheets (MSDS) Globally Harmonized System (GHS) of Classification and Labeling of Chemicals Training Program Gwinnett Hospital System Right-to-Know Training Objectives After

More information

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series Section > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series 22 23 > CABLE GLANDS WITH DEVICE TO PREVENT ANY UNSCREWING UNION Series B (*) IP8 (1 bar) C A in mm A B

More information

Hazard Communication & Chemical Safety. Based on OSHA Standard

Hazard Communication & Chemical Safety. Based on OSHA Standard Hazard Communication & Chemical Safety Based on OSHA Standard 1910.1200 We use many chemicals We want you to know how to use them safely You will learn about The Hazards of Chemicals Our Written Program

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Hazcom 2012: Changes to the OSHA Hazard Communication Standard. Risk Engineering

Hazcom 2012: Changes to the OSHA Hazard Communication Standard. Risk Engineering Hazcom 2012: Changes to the OSHA Hazard Communication Standard Risk Engineering Objectives Outline changes to in the OSHA Hazard Communication Standard Review key changes to labels Discuss the new Safety

More information

The Solubility is the Solution

The Solubility is the Solution The Solubility is the Solution The Company BellandTechnology AG is a polymer technology company, originally founded in Switzerland 1983. BellandTechnology developed a proprietary selectively soluble polymer

More information

12.1 Schlüter -KERDI-BOARD

12.1 Schlüter -KERDI-BOARD Innovative profiles 12.1 Schlüter -KERDI-BOARD S u b s t r a t e UNIVERSAL STRUCTURAL PANEL, BONDED WATERPROOFING Application and Function Schlüter -KERDI-BOARD is a multifunctional tile substrate for

More information

Modular contactors for installation into distribution

Modular contactors for installation into distribution Modular contactors for installation into distribution boards Modular contactors for installation into distribution boards Modular contactor for installation into distribution board Description Modular

More information

Material Safety Data Sheet acc. to ISO/DIS 11014

Material Safety Data Sheet acc. to ISO/DIS 11014 Page 1/6 1 Identification of the substance/mixture and of the company/undertaking Product Identifier Catalog Number: 225250 Details of the supplier of the safety data sheet Manufacturer/Supplier: BD Diagnostic

More information

VD1 CLC. Small Valves DIN-range with a higher k v -value

VD1 CLC. Small Valves DIN-range with a higher k v -value 0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-2 umodule SPOT C.PHASED NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-2 umodule SPOT C.PHASED NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

Kalinka Optics Warehouse User Manual  Kobra AK Side Mount Red Dot Sight Manual Kalinka Optics Warehouse User Manual www.kalinkaoptics.com Kobra AK Side Mount Red Dot Sight Manual CONTENTS 1. Introduction... 4 2. Purpose... 4 3. Specifications... 4 4. Components and Equipment Provided...

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5 Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Lifetime up to 5, hours Compact design Excellent thermal management 1 NTC for temperature control

More information

Underlayment. bonded impact sound insulation

Underlayment. bonded impact sound insulation Schlüter -DITRA-SOUND Underlayment 6.3 bonded impact sound insulation Product data sheet Application and Function Schlüter -DITRA-SOUND is a bonded impact sound insulation for tile coverings, made of a

More information

Structural Calculations for Juliet balconies using BALCONY 2 System (Aerofoil) handrail. Our ref: JULB2NB Date of issue: March 2017

Structural Calculations for Juliet balconies using BALCONY 2 System (Aerofoil) handrail. Our ref: JULB2NB Date of issue: March 2017 Juliet balconies using BALCONY 2 System (Aerofoil) handrail PAGE 1 (ref: JULB2NB280317) Structural Calculations for Juliet balconies using BALCONY 2 System (Aerofoil) handrail Our ref: JULB2NB280317 Date

More information

PART 5-1: Compartment fire

PART 5-1: Compartment fire PART 5-1: Compartment fire P. Schaumann T. Trautmann University of Hannover Germany J. Žižka Czech Technical University in Prague Czech Republic 1 TASK The gas temperature of a fully engulfed fire in an

More information

Procedure for determining radionuclides in foodstuffs at elevated levels of contamination by gamma spectrometry

Procedure for determining radionuclides in foodstuffs at elevated levels of contamination by gamma spectrometry Procedure for determining radionuclides in foodstuffs at elevated levels of contamination by gamma spectrometry E- -SPEKT-LEBM-02 Authors: O. Frindik M. Heilgeist W. Kalus R. Schelenz Federal coordinating

More information

*These are the vinyl for MAX Bepop Cutting/printing machines. We have 100mm (4in) and 200mm(8in) width models available in North America.

*These are the vinyl for MAX Bepop Cutting/printing machines. We have 100mm (4in) and 200mm(8in) width models available in North America. The English translation of Bepop standard vinyl (indoor use) technical datasheet 100mm (4in) / 200mm (8in) width Color 100mm(4in) width 200mm(8in) width Black SL-S111N Black SL-S201N Black White SL-S112N

More information

12.1 Product data sheet

12.1 Product data sheet Schlüter -KERDI-BOARD Substrate universal structural panel, bonded waterproofing 12.1 Product data sheet Application and Function Schlüter -KERDI-BOARD is a multifunctional tile substrate for wall areas,

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

ZF Series Force Transducers

ZF Series Force Transducers Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-2 umodule SPOT C.PHASED NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-2 umodule SPOT C.PHASED NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

We Provide a Variety of Product Ranges Catering for an array of Usage Requirements.

We Provide a Variety of Product Ranges Catering for an array of Usage Requirements. We Provide a Variety of Product Ranges Catering for an array of Usage Requirements. Adhesive/FIXing Function ADSORBENT ADHESIVE SURFACE FUNCTION FUJICOPIAN's Functional Film About FIXFILM is a collective

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Material Safety Data Sheet acc. to ISO/DIS 11014

Material Safety Data Sheet acc. to ISO/DIS 11014 Page 1/5 1 Identification of substance: Catalog number: 248810 Manufacturer/Supplier: BD Diagnostic Systems 7 Loveton Circle Sparks, MD 21152 Tel: (410) 771-0100 or (800) 638-8663 Information department:

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-3 EM umodule SPOT PHASED OUT NTC NTC LED + LED + LED EM LED EM

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-3 EM umodule SPOT PHASED OUT NTC NTC LED + LED + LED EM LED EM Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Lifetime up to 5, hours Compact design Excellent thermal management NTC for temperature control High-power

More information

Material Safety Data Sheet acc. to ISO/DIS 11014

Material Safety Data Sheet acc. to ISO/DIS 11014 Page 1/7 1 Identification of the substance/mixture and of the company/undertaking Product Identifier Catalog Number: 211677 Relevant identified uses of the substance or mixture and uses advised against

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-3 EM umodule SPOT PHASED OUT 39,5 35,5 NTC NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-3 EM umodule SPOT PHASED OUT 39,5 35,5 NTC NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Lifetime up to 5, hours Compact design Excellent thermal management NTC for temperature control High-power

More information

Material Safety Data Sheet acc. to ISO/DIS 11014

Material Safety Data Sheet acc. to ISO/DIS 11014 Page 1/5 1 Identification of the substance/mixture and of the company/undertaking Product Identifier Catalog Number: 22974 Details of the supplier of the safety data sheet Manufacturer/Supplier: BD Diagnostic

More information

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method INTERNATIONAL STANDARD ISO 10494 Second edition 2018-04 Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method Turbines et groupes de turbines Mesurage du bruit aérien

More information

Influence Of The Substrates On Water-based Paints Emissions Fabio Abbà,1*, Mikaela Decio 2, Tiziano Cerulli 2 and Roberto Leoni 2

Influence Of The Substrates On Water-based Paints Emissions Fabio Abbà,1*, Mikaela Decio 2, Tiziano Cerulli 2 and Roberto Leoni 2 Influence Of The Substrates On Water-based Paints Emissions Fabio Abbà,1*, Mikaela Decio 2, Tiziano Cerulli 2 and Roberto Leoni 2 1 Vinavil S.p.A. R & D Laboratory, Via Toce, 7, 28844 Villadossola, Italy

More information

STEEL. General Information

STEEL. General Information General Information General Information TYPICAL STRESS-STRAIN CURVE Below is a typical stress-strain curve. Each material has its own unique stress-strain curve. Tensile Properties Tensile properties indicate

More information

Material Safety Data Sheet acc. to ISO/DIS 11014

Material Safety Data Sheet acc. to ISO/DIS 11014 Page 1/6 1 Identification of the substance/mixture and of the company/undertaking Product Identifier Catalog Number: 220971 Details of the supplier of the safety data sheet Manufacturer/Supplier: BD Diagnostic

More information

SAFETY DATA SHEET 041-PIMMCB-50/041-PIMMCB-100. Pro-Pest Pheronet Pheromone Trap and

SAFETY DATA SHEET 041-PIMMCB-50/041-PIMMCB-100. Pro-Pest Pheronet Pheromone Trap and 1 Identification 1.1 Product identifier Product code Product name 041-PIMMCB-50/041-PIMMCB-100 Pro-Pest Pheronet Pheromone Trap Other means of identification Recommended use Restrictions for use Active

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET 1.Product Identification Manufacturer : Address : Clayton 3168 Ph 03 9542 6666 Fax 03 9542 6677 www.colorific.com.au Intended Use : artists. Colorific Australia Gate 2, Clayton Business Park, Rayhur St

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

custom reticle solutions

custom reticle solutions custom reticle solutions 01 special micro structures Pyser Optics has over 60 years experience in producing high quality micro structure products. These products are supplied worldwide to industries including

More information

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2. 2.9 page 175 Namur 1/4 also called Namur 1 in accordance to VDI / VDE 3845. Namur 1/2 also called Namur 2. 2.9 Namur Valves + Selected models are available for low temperature application. Temperature-range:

More information

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016 APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

Title: Cesa-extend a User Friendly Technology to Enhance Reprocessing and Recycling of Condensation Plastics

Title: Cesa-extend a User Friendly Technology to Enhance Reprocessing and Recycling of Condensation Plastics GPEC 24 Paper Abstract #52: Title: Cesa-extend a User Friendly Technology to Enhance Reprocessing and Recycling of Condensation Plastics Author(s): V. Karayan, Clariant Masterbatches, and M. Villalobos,

More information

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and selfadhesive tape, a Flexible Elastomeric Foam product complying with the European standard EN. EUROBATEX is a closed

More information

From Table 1 4. DL = [12 lb/ft 2 # in.(6 in.)] (15 ft)(10 ft) = 10,800 lb. LL = (250 lb/ft 2 )(15 ft)(10 ft) = 37,500 lb.

From Table 1 4. DL = [12 lb/ft 2 # in.(6 in.)] (15 ft)(10 ft) = 10,800 lb. LL = (250 lb/ft 2 )(15 ft)(10 ft) = 37,500 lb. 1 1. The floor of a heavy storage warehouse building is made of 6-in.-thick stone concrete. If the floor is a slab having a length of 15 ft and width of 10 ft, determine the resultant force caused by the

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

M A C H I N E L I S T - P R O D U C T I O N P R O C E S S E S

M A C H I N E L I S T - P R O D U C T I O N P R O C E S S E S S P E C T R U M O F S E R V I C E S G R A P H I C S All commonly available programmes C O N S T R U C T I O N CAD, 3D construction, static loading, structural analysis interfaces to industrial construction

More information

Determination of particle size distribution Single particle light interaction methods. Part 4:

Determination of particle size distribution Single particle light interaction methods. Part 4: Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 21501-4 Second edition 2018-05 Determination of particle size distribution Single particle light interaction methods Part 4: Light scattering airborne

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV Uengine DLE G2 integrated ADV uengine DLE Product description Module with integrated electronics For downlights Light engine operating with 23 V AC Luminous flux range from 1,24 2,43 lm High system efficacy

More information

Chemical Storage Guide

Chemical Storage Guide 1 P a g e Chemical Storage Guide It is the responsibility of every occupant, owner, tenant, contractor, employee & visitor and ALL users of this facility to ensure they take all reasonably practical steps

More information

P8D137. Features. Applications. Power UV LED Series is designed for high current operation and high flux output applications. Super high Flux output

P8D137. Features. Applications. Power UV LED Series is designed for high current operation and high flux output applications. Super high Flux output P8D137 Power UV LED Series is designed for high current operation and high flux output applications. P8D137 Features Super high Flux output and high Luminance Furthermore, its thermal management characteristic

More information