1 SKAPS INDUSTRIES 571 Industrial Pkwy, Commerce, GA Phone: (706) Fax: (706) E Mail: contact@skaps.com SKAPS GEOCOMPOSITE DROP IN 2016 SKAPS Industries
2 1. GENERAL 1.1 SCOPE OF WORK A. The Contractor furnish all labor, materials, tools, supervision, transportation, and installation equipment necessary for the installation of geocomposite, as specified herein, as shown on the Construction Drawings, and in accordance with Construction Quality Assurance (CQA) Plan. B. The Contractor shall install geocomposite in conjunction with the earthwork and other components of the project. 1.2 REFERENCES A. Construction Quality Assurance (CQA) Plan B. Latest Version of American Society for Testing and Materials (ASTM) standards 1) ASTM D 1238, Standard Test Method for Measuring Melt Flow Rates of Thermoplastics by Extrusion Plastometer. 2) ASTM D 1505, Standard Test Method for Density of Plastics by the Density Gradient Technique. 3) ASTM D 4218, Standard Test Method for Determination of Carbon Black Content in Polyethylene Compound by the Muffle Furnace Technique. 4) ASTM D 4716, Standard Test Method Determining the (In Plane) Flow Rate Per Unit Width and Hydraulic Transmissivity of Geosynthetic Using a Constant Head. 5) ASTM D 7179, Standard Test Method for Determining Geonet Breaking Force. 6) ASTM D 5199, Standard Test Method for Measuring Nominal Thickness. 7) ASTM D 5261, Standard Test Method for Measuring the Mass Per Unit Area of Geonet and Geotextiles. 8) ASTM D 4751, Standard Test Method for Determining Apparent Opening Size of Geotextiles. 9) ASTM D 4491, Standard Test Method for Water Permeability of Geotextiles by Permittivity method. 10) ASTM D 4533, Standard Test Method Trapezoid Tearing Strength of Geotextiles. 11) ASTM D 4632, Standard Test Method for Grab Breaking Load and Elongation of Geotextiles (Grab Method). 12) ASTM D 6241, Standard Test Method for CBR Puncture Resistance of Geotextiles. 1.3 QUALIFICATIONS A. MANUFACTURER 1) The Geocomposite Manufacturer shall be responsible for the production of geocomposite rolls and shall be well established firm with more than 10 years of experience in the manufacture of geocomposite. 2) The Geocomposite Manufacturer shall have manufactured a minimum of 10,000,000 square feet of geocomposite during the last year. B. INSTALLER 1) The Installer shall be responsible for field handling, storing, deploying, seaming or joining, temporary restraining against wind, anchoring systems, and other site aspects of the geocomposite. 2
3 2) The Installer shall be trained and qualified to install geocomposites. 3) The Installer shall have a minimum of 1,000,000 square feet of geocomposite in the last 5 (five) years. 4) The Installation Supervisor shall have worked in a similar capacity on projects similar in complexity to the project described in the contract documents. 1.4 MATERIAL LABELING, DELIVERY, STORAGE AND HANDLING A. LABELING Each roll delivered to the site shall be wrapped and labeled by the manufacturer. The label will identify: 1) Manufacturer s name 2) Product identification 3) Length 4) Width 5) Roll number B. DELIVERY Rolls will be prepared to ship by appropriate means to prevent damage to the material and to facilitate off loading. C. STORAGE The on site storage location provided by the contractor to protect the geocomposite from abrasions, excessive dirt and moisture shall have the following characteristics: 1) Level (no wooden pallets) 2) Smooth and dry surface 3) Protected from theft and vandalism D. HANDLING 1) The contractor and installer shall handle all rolls in such a manner to ensure they are not damaged in any way. 2) The installer shall take necessary precautions to prevent damage to underlying layers during placement of the geocomposite. 1.5 WARRANTY A. Material shall be warranted on a pro rata basis against defects for a period or one year from the date of the geocomposite installation. B. Installation shall be warranted against defects in workmanship for a period of one year from the date of the geocomposite installation. 3
4 2. PRODUCTS 2.1 GEOCOMPOSITE PROPERTIES The geocomposite shall be manufactured by extruding two crossing strands to form a bi planar drainage net with non woven geotextile heat bonded to one or both sides. The manufacturer shall furnish geocomposite having properties that comply with the required property values shown in Table 1. The manufacturer shall provide certification that the materials meet or exceed the required values. Geonet Property Test Method Required Value Qualifier Thickness ASTM D 5199 MAV (3) Carbon Black ASTM D 4218 MAV Tensile Strength ASTM D 7179 MAV Melt Flow ASTM D 1238 (2) Maximum Density ASTM D 1505 MAV Transmissivity (1) ASTM D 4716 MAV Geocomposite Ply Adhesion ASTM D 7005 MAV Transmissivity (1) ASTM D 4716 MAV Geotextile Fabric Weight ASTM D 5261 MARV (4) Grab Tensile ASTM D 4632 MARV Grab Elongation ASTM D 4632 MARV Trapezoid Tear Strength ASTM D 4533 MARV CBR Puncture ASTM D 6241 MARV Water Flow (5) ASTM D 4491 MARV Permittivity (5) ASTM D 4491 MARV Permeability (5) ASTM D 4491 MARV AOS ASTM D 4751 MaxARV (1) Transmissivity measured using water at 21+2 o C (70+4 o F) with a gradient of 0.1 and a confining pressure of 10,000 psf between steel plates after 15 minutes (2) Condition 190/2.16 (3) Minimum average value (4) MARV is statistically defined as mean minus two standard deviations and it is the value which is exceeded by 97.5% of all the test data (5) At the time of manufacturing. Handling may change these properties. 4
5 2.2 MANUFACTURER QUALITY CONTROL A. The geocomposite shall be manufactured with quality control procedures that meet generally accepted industry standards. B. The geocomposite manufacturer shall sample and test the geocomposite rolls to demonstrate that the material conforms to the requirements of this section. C. Any geocomposite sample does not comply with this section shall result in rejection of the roll from which the sample was obtained. The rejected roll shall not be used. D. The geocomposite shall be tested by the geocomposite manufacturer for quality control, at the typical frequencies used at manufacturer s plant to evaluate its physical and mechanical properties. E. Geocomposite shall be supplied in rolls wrapped in relatively impermeable and opaque covers. 2.3 TRANSPORT A. Transportation of the geocomposite shall be the responsibility of the contractor. B. During shipment, the geocomposite shall be protected from ultraviolet light exposure, precipitation, mud, dirt, dust, puncture, or other damaging and deteriorating conditions. 3. EXECUTION 3.1 FAMILIARIZATION A. Prior to implementing any of the work, the installer shall carefully inspect the installed work and verify that all work is complete to the point where the next installation may properly commence without adverse impact. B. If the installer has any concerns regarding the installed work, he/she shall notify the project engineer. 3.2 MATERIAL PLACEMENT A. The geocomposite rolls shall be handled in such manner as to ensure that they are not damaged in any way. B. The geocomposite shall be installed to the lines and grades as shown on the contract drawings and as described herein. C. The geocomposite shall be rolled down the slope in such manner as to continuously keep the geocomposite in tension by self weight. The geocomposite shall be securely anchored in an anchor trench where applicable, or by other approved or specified methods. D. In the presence of wind, all geocomposite shall be weighted down with sandbags or approved equivalent. Such anchors shall be used during placement and shall remain in place until replaced with cover material. E. The contractor shall take necessary precautions to prevent damage to adjacent or underlying materials during placement of the geocomposite. F. The contractor shall take care not to entrap soil, stones or excessive moisture in the geocomposite during placement. G. After unwrapping, the geocomposite shall not be exposed to direct sun light for more than 21 days unless approved by the Engineer. H. In applying fill material, no equipment can drive directly across the geocomposite. The specified fill material shall be placed and spread utilizing vehicles with low ground pressure. 5
6 I. Placement of cover soil shall proceed immediately following the placement and inspection of the geocomposite. 3.3 SEAMS AND OVERLAPS A. Each component of the geocomposite shall be secured or seamed to the like component at overlaps. B. Geonet Components 1) Adjacent edges of along the length of the geonet roll shall be overlapped a minimum of 4 inches or as recommended by the Engineer. 2) The overlapped edges shall be joined by tying the geonet using natural or yellow cable ties spaced every five feet along roll length. 3) Adjoining rolls across the roll width should be shingled down in the direction of the slope and joined together with cable ties spaced every one foot along the roll width C. Geotextiles Components 1) The geocomposite shall be seamed using heat seaming or stitching methods as recommended by the manufacturer and approved by the Engineer. All sewn seams shall be continuous. 2) Seams shall be oriented down slopes perpendicular to grading contours unless otherwise specified. 3) Polymeric thread, with chemical resistance properties equal to or exceeding those of the geocomposite, shall be used for all sewing. 3.4 REPAIR A. Prior to covering the deployed geocomposite, each roll shall be inspected for damage resulting from construction. B. Any rips, tears or damaged areas on the deployed geonet shall be removed and patched. The patch shall be secured to the original geonet by tying every six inches with approved tying devices. If the area to be repaired is more than 50 percent of the width of the panel, the damaged area shall be cut out and two portions of the remaining geonet shall be joined in accordance with above subsection 3.3. C. Care shall be taken to remove any soil or other material which may have penetrated to geonet. 6
Provide sediment tubes for ditch check and Type A inlet structure filter applications that meet the minimum performance requirements of Table 1.
Supplemental Technical Specification for SEDIMENT TUBES SCDOT Designation: SC-M-815-1 (03/08) 1.0 Sediment Tubes This Supplemental Specification replaces sections 815.1.1.2, 815.2.3, 815.4.5, 815.5, and
More informationGuide Specifications Section
Guide Specifications Section 08 87 23 SAFETY-AND-SECURITY FILMS LLumar Safety-and-Security Series Note: Click on Show/Hide button to reveal "Specifier Notes" throughout section. Delete this text when editing
More informationStone Outlet Sediment Trap
3.12 Sediment Control Description: A stone outlet sediment trap is a small detention area formed by placing a stone embankment with an integral stone filter outlet across a drainage swale for the purpose
More informationMaterials. Use materials meeting the following.
208.01 Section 208. SOIL EROSION AND SEDIMENTATION CONTROL 208.01 Description. Install and maintain erosion and sedimentation controls to minimize soil erosion and to control sedimentation from affecting
More informationGEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE
GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE Prof. J. N. Mandal Department of civil engineering, IIT Bombay, Powai, Mumbai 400076, India. Tel.022-25767328 email: cejnm@civil.iitb.ac.in Module - 4
More informationSECTION AGGREGATE OR GRANULAR SUBBASE
SECTION 02230 AGGREGATE OR GRANULAR SUBBASE PART 1 GENERAL 1.01 SECTION INCLUDES A. Aggregate or granular subbase as shown on the drawings. 1.02 RELATED SECTIONS A. Section 01400 Quality Requirements.
More informationMay 1, Sincerely, Jeffrey M. Loewe Principal NiSource Environmental. 801 E. 86th Avenue, Merrillville, IN
May 1, 2018 Ms. Alicia Brown Indiana Department of Environmental Mgmt OLQ, Solid Waste Permits Branch 100 N Senate Avenue MC 65-45 IGCN 1101 Indianapolis, IN 46204-2251 RE: Follow up to Request for Additional
More informationIntroduction to Geohazard Standard Specification for Simple Drapery
Introduction to Geohazard Standard Specification for Simple Drapery Up to now, there is no standard specification for geohazard solutions in North America. Often projects specifications are referring to
More informationU-Shaped Sediment Traps
U-Shaped Sediment Traps SEDIMENT CONTROL TECHNIQUE Type 1 System Sheet Flow Sandy Soils Type 2 System Concentrated Flow Clayey Soils [1] Type 3 System Supplementary Trap Dispersive Soils [1] Generally
More informationCoarse Sediment Traps
Coarse Sediment Traps SEDIMENT CONTROL TECHNIQUE Type 1 System Sheet Flow Sandy Soils Type 2 System [1] Concentrated Flow Clayey Soils [2] Type 3 System Supplementary Trap Dispersive Soils [1] Though primarily
More informationAvery Dennison LW Series Retroreflective Window Sticker Film Issued: July 2013
LW series window stickers are designed to be variable printed for use inside or outside the vehicle. Reflective permit stickers provide easy verification for authenticity. Performance: L-S-300C Table IV
More informationFOR PROJECTS INITIATED AFTER NOVEMBER 1, 2008 ITEM 716 EMBANKMENT EARTH OUTLET SEDIMENT TRAP
AFTER NOVEMBER 1, 2008 ITEM 716 EMBANKMENT EARTH OUTLET SEDIMENT TRAP 716.1 Description. This work shall consist of furnishing, installing, maintaining, and removing temporary erosion protection and sediment
More informationWIESON TECHNOLOGIES CO., LTD.
TABLE OF CONTENT 1. Scope.... 2 2. Reference Documents. 2 3. Material and Components.... 2 4. Design and Construction.... 2 5. Rating.. 2 6. Performance and Test Descriptions. 2 7. Test Requirements and
More informationGEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE
GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE Prof. J. N. Mandal Department of civil engineering, IIT Bombay, Powai, Mumbai 400076, India. Tel.022-25767328 email: cejnm@civil.iitb.ac.in Module - 4
More informationSLOPE STABILITY EVALUATION AND ACCEPTANCE STANDARDS
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 98.0508 Effective: 1-26-84 DOCUMENT NO. P/BC 2002-049 Revised: 11-1-02 Previously Issued As: RGA #1-84 SLOPE STABILITY EVALUATION AND ACCEPTANCE
More informationEFFECT OF SOIL PRESENCE ON FLOW CAPACITY OF DRAINAGE GEOCOMPOSITES UNDER HIGH NORMAL LOADS. Aigen Zhao, Tenax Corporation, Baltimore, Maryland, U.S.A.
EFFECT OF SOIL PRESENCE ON FLOW CAPACITY OF DRAINAGE GEOCOMPOSITES UNDER HIGH NORMAL LOADS Aigen Zhao, Tenax Corporation, Baltimore, Maryland, U.S.A. Filippo Montanelli, Tenax SpA, Vigano, Italy ABSTRACT:
More informationAvery Dennison LV-0700 Series Retroreflective Validation Decal Film Issued: July 2013
LV-0700 Series Reflective film is a quality, enclosed lens retorreflective material. LV- 0700 is ideal for vehicle tag and sticker requirements where low temperature application is desired such as for
More informationproduct manual H-4204 Proving Ring Penetrometer
05.09 product manual H-4204 Proving Ring Penetrometer nnmm Handle Proving Ring Extension Rod Coupler Penetration Rod Cone Figure #1 General Information The Proving Ring Penetrometer is a cone type of penetrometer
More informationProtective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153.
Technical Services: Tel: (66) 500-76 / Fax: (01) 71-7317 www.grinnell.com Grinnell Mechanical Products Grooved Fittings, Ductile Iron & Fabricated Steel General Description Grooved fittings provide an
More information[1] Performance of the sediment trap depends on the type of outlet structure and the settling pond surface area.
Sediment Trench SEDIMENT CONTROL TECHNIQUE Type 1 System Sheet Flow Sandy Soils Type 2 System [1] Concentrated Flow Clayey Soils Type 3 System [1] Supplementary Trap Dispersive Soils [1] Performance of
More informationAM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No
AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS October, 1999 IM No. 597 1112 EQUIPMENT LOST OR DAMAGED IN TRANSIT. When delivering the equipment to you, the truck driver or carrier s agent
More informationGB/T / ISO 527-1:1993
Translated English of Chinese Standard: GB/T1040.1-2006 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 83.080.01 G 31 GB/T 1040.1-2006 / ISO
More informationSTATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION. Price: $5.00. Revised March 31, 1997
STATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION Revised March 31, 1997 Price: $5.00 a. an arrangement where the water pipe to be injected with chlorine enters
More informationOperating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2
Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2 P/N VALTOL-KT2 Revision 2.0 October 7, 2014 Prepared by: Quality Lab Accessories, LLC 100 Emlen Way, Suite 108 Telford,
More informationAvery Dennison L-3050 Series Retroreflective License Plate Film September 2013 Revision 2
Avery Dennison L-3050 Series Retroreflective sheeting is a premium quality enclosed lens retroreflective material designed and engineered for the production of high quality embossed license plates. It
More informationMATERIAL AND EQUIPMENT STANDARD FOR. INHIBITOR FOR HYDROCHLORIC ACID AND HCl+HF DESCALING AND PICKLING SOLUTION FOR OIL AND GAS WELLS ORIGINAL EDITION
IPS-M-TP- 676 MATERIAL AND EQUIPMENT STANDARD FOR INHIBITOR FOR HYDROCHLORIC ACID AND HCl+HF AS DESCALING AND PICKLING SOLUTION FOR OIL AND GAS WELLS ORIGINAL EDITION DEC. 1997 This standard specification
More informationALUMINUM STRUCTURAL PLATE HEADWALLS AASHTO LRFD BASIS OF DESIGN
ALUMINUM STRUCTURAL PLATE EADWALLS AASTO LRFD BASIS OF DESIGN LANE ENTERPRISES, INC. www.lane-enterprises.com Required Backfill and Load Cases: ALUMINUM STRUCTURAL PLATE EADWALLS BASIS OF DESIGN Backfill
More informationIntroduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
More informationHazard Communication
Hazard Communication For Company: Address: LC-1009 Rev. 06/16 Page 1 Hazard Communication Program Ref: OSHA 1910.1200 Approved by: Title: Ranking Official's Signature Date: Hazard Communication Coordinator
More informationREVISIONS SYMBOL DESCRIPTION DATE APPROVAL
REVISIONS SYMBOL DESCRIPTION DATE APPROVAL - A Initial Release Revised per RN A-159 03/11/2008 07/17/2009 JS SHEET REVISION STATUS SH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 REV A A A A A A
More informationASTM upvc Schedule 80
ASTM upvc PRESSURE PIPING SYSTEM SPECIFICATION Pipes Standards & Quality Sch. 80 pipe is manufactured to comply with NSF Standard 61, CSA B 137.3 and ASTM D1785, consistently meeting the Quality Assurance
More informationLUDLUM MODEL 42-5 NEUTRON BALL CART. August 2015 Serial Number PR and Succeeding Serial Numbers
LUDLUM MODEL 42-5 NEUTRON BALL CART August 2015 Serial Number PR149512 and Succeeding Serial Numbers LUDLUM MODEL 42-5 NEUTRON BALL CART August 2015 Serial Number PR149512 and Succeeding Serial Numbers
More informationSediment Trap. A temporary runoff containment area, which promotes sedimentation prior to discharge of the runoff through a stabilized spillway.
Sediment Trap SC-15 Source: Caltrans Construction Site Best Management Practices Manual, 2003. Description A temporary runoff containment area, which promotes sedimentation prior to discharge of the runoff
More informationOwner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL
Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL 1 1. CONTENTS 2. Nomenclature page 3 3. Care and Maintenance page 4 4. Using your Instrument 4.1 Setting up your Instrument page 5 4.2 Stadia
More informationDIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: PNEUTEK, INC.
ICC ES Report ICC ES () 7 () www.icc es.org Most Widely Accepted and Trusted ESR 1 Reissued /1 This report is subject to renewal /. DIVISION: METALS SECTION: METAL FASTENINGS SECTION: 1 STEEL ING REPORT
More informationNORTH DAKOTA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TEMPORARY EROSION AND SEDIMENT BEST MANAGEMENT PRACTICES
Page 1 of 5 NORTH DAKOTA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TEMPORARY EROSION AND SEDIMENT BEST MANAGEMENT PRACTICES 1. GENERAL Install, maintain and remove appropriate Temporary Best Management
More informationRoHS. Specification CUD8DF1A. Drawn Approval Approval. 서식 Rev: 00
Specification RoHS CUD8DF1A SVC Customer Drawn Approval Approval 1 [ Contents ] 1. Description 2. Outline dimensions 3. Characteristics of CUD8DF1A 4. Characteristic diagrams 5. Binning & Labeling 6. Reel
More informationSLOPE STABILITY EVALUATION AND ACCEPTANCE STANDARDS
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC 7006.3, 7014.1 Effective: 01-01-2017 DOCUMENT NO.: P/BC 2017-049 Revised: 12-21-2016 Previously Issued As: P/BC 2014-049 SLOPE STABILITY
More informationTESTING of AGGREGATES for CONCRETE
TESTING of AGGREGATES for CONCRETE The properties of the aggregates affect both the fresh and hardened properties of concrete. It is crucial to know the properties of the aggregates to be used in the making
More informationEOSMS Guidelines Date: 01/16/2014 Page 1 of 5
EOSMS Guidelines Date: 01/16/2014 Page 1 of 5 Introduction The Department of Environmental Health, Safety has developed generic standard operating procedures relevant to safety and health considerations
More informationOrica Australia Pty Ltd Ammonium Nitrate Facility Upgrade
Orica Australia Pty Ltd Ammonium Nitrate Facility Upgrade January 2010 Revision 0 Contents 1. Introduction 1 1.1 Purpose 1 1.2 Objectives 1 1.3 Relevant Environmental Legislation, Guidelines and Policies
More informationB805 TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES - OPSS 805
B805 MEASURES - OPSS 805 805.1 GENERAL Construction activities frequently remove protective cover and expose soil to accelerated rates of erosion. Sediments generated thereby can be conveyed via runoff
More informationM I N I S T R Y O F C O M M U N I C A T I O N S T E L E C O M M U N I C A T I O N S S E C T O R T E C H N I C A L S T A N D A R D F O R
M I N I S T R Y O F C O M M U N I C A T I O N S T E L E C O M M U N I C A T I O N S S E C T O R T E C H N I C A L S T A N D A R D F O R M A T E R I A L S N O. G 2 0 : 1 0 : 0 0 1 : 1 8 J U M P E R W I
More informationPVC - WHITE PRESSURE FITTINGS PRODUCTS PRICE LIST INCLUDES: PVC SCHEDULE 40, CLASS 125, POOL/SPA, LASCOTITE, ULTRAFIX REPAIR COUPLINGS PRICE GROUP
PRICE GROUP DESCRIPTION 01 SCH 40 PVC through 8 91 SCH 40 PVC 10" AND LARGER 96 CLASS 125 10 & 12 09 POOL AND SPA 14 LASCOTITE 15 ULTRAFIX REPAIR COUPLING DISCOUNT MULTIPLIER PRODUCTS PVC - WHITE PRESSURE
More informationProduct Data Sheet PD-0053-A
Product Data Sheet PD-0053-A 3M Mini D Ribbon (MDR) Connector MDR Surface Mount 102XX-1210 XE 102XX-1S10 XE Page: 1 of 11 Table of Contents 1.0 SCOPE...2 2.0 PRODUCT TESTED...2 3.0 GENERAL CONDITIONS...2
More informationLow Gradient Velocity Control Short Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1]
Rock Linings DRAINAGE CONTROL TECHNIQUE Low Gradient Velocity Control Short Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1] [1] The design of permanent installations
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 21307 Second edition 2011-05-15 Plastics pipes and fittings Butt fusion jointing procedures for polyethylene (PE) pipes and fittings used in the construction of gas and water
More informationSpecification for Embedded Passive Device Capacitor Materials for Rigid and Multilayer Printed Boards
IPC-4821 ASSOCIATION CONNECTING ELECTRONICS INDUSTRIES Specification for Embedded Passive Device Capacitor Materials for Rigid and Multilayer Printed Boards Developed by the Embedded Component Materials
More informationRetroreflective Prismatic License Plate Film
Avery Dennison L-6050 Series Issued: April 2011 Avery Dennison L-6050 Series Retroreflective sheeting is a premium quality prismatic retroreflective material designed and engineered for the production
More informationProduct Series Specification Document
Product Series 3.96mm pitch board-to-board connectors - Socket SCOPE This document covers 3.96mm socket connectors. The connector will perform to the specifications outlined. All tests have been performed
More informationGRI Guide GS12 * Lifetime Prediction of Geosynthetics Using Time-Temperature-Superposition (TTS) and Arrhenius Modeling
Geosynthetic Institute 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GEI GRI GSI GAI GCI GII Original: December 10, 2012 GRI Guide GS12 * Standard Guide for Lifetime
More informationStandard Classification System for Rubber Products in Automotive Applications 1
Designation: D 2000 0 Approved by Society of Automotive Engineers SAE Recommended Practice J200 Standard Classification System for Rubber Products in Automotive Applications 1 This standard is issued under
More informationEVALUATING SEDIMENT BARRIERS
EVALUATING SEDIMENT BARRIERS Presented at IECA 2014, Nashville, TN C. Joel Sprague, P.E. TRI/Environmental, Inc. PO Box 9192, Greenville, SC 29604 Phone: 864/242-2220; Fax: 864/242-3107; jsprague@tri-env.com
More informationInside Wall Temperature Measurements of DSTs Using an Infrared Temperature Sensor
TEST PLAN Inside Wall Temperature Measurements of DSTs Using an Infrared Temperature Sensor Date submitted: December 18, 2015 Prepared by: Aparna Aravelli, Ph.D. Florida International University Collaborators:
More informationArmy Air Forces Specification 7 December 1945 EQUIPMENT: GENERAL SPECIFICATION FOR ENVIRONMENTAL TEST OF
Army Air Forces 41065 Specification 7 December 1945 EQUIPMENT: GENERAL SPECIFICATION FOR ENVIRONMENTAL TEST OF A. APPLICABLE SPECIFICATIONS A-1. The current issue of the following specifications, in effect
More informationConstruction Exits Rock pads
Construction Exits Rock pads SEDIMENT CONTROL TECHNIQUE Type 1 System Sheet Flow Sandy Soils Type 2 System Concentrated Flow [1] Clayey Soils Type 3 System Supplementary Trap Dispersive Soils [1] Minor
More information2018 North Carolina Residential Code Prescriptive Tables for Selection of Support Elements for Beams, Girders, and Headers: Example Problems
2018 North Carolina Residential Code Prescriptive Tables for Selection of Support Elements for Beams, Girders, and Structural Building Components Association (SBCA) August 10, 2018 SBCA is an APPROVED
More informationSediment Control Log (SCL)
Description A sediment control log is a linear roll made of natural materials such as straw, coconut fiber, or other fibrous material trenched into the ground and held with a wooden stake. Sediment control
More informationCommonwealth of Pennsylvania PA Test Method No. 729 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for
Commonwealth of Pennsylvania PA Test Method No. 729 Department of Transportation 14 Pages LABORATORY TESTING SECTION Method of Test for SAMPLING ROADWAY BITUMINOUS CONCRETE 1. SCOPE 1.1 This method covers
More informationHEAVY DUTY SWING-OUT VALVE
ISO 900 REGISTERED COMPANY Akron Brass Company. 20 All rights reserved. No portion of this can be reproduced without the express written consent of Akron Brass Company. We will not be responsible for:
More information1 /square Intermittent temperature range -250 C to 150 C (-420 F to 300 F) Continuous temperature range -250 C to 120 C (-420 F to 250 F)
PRODUCT BULLETIN Aluminum Coated (Two Sides) PET Aluminum PET Aluminum MLI MATERIALS Sheldahl Brand Materials of Polyethylene Terephthalate (PET or polyester) films that are aluminized on both sides can
More informationSediment Weirs (Instream)
Sediment Weirs (Instream) INSTREAM PRACTICES Flow Control No Channel Flow Dry Channels Erosion Control Low Channel Flows Shallow Water Sediment Control High Channel Flows [1] Deep Water [1] Sediment weirs
More informationQualification Test Report. Modular Plugs, Unshielded and Shielded
Qualification Test Report 501-131013 26 JAN 16 Rev. A Modular Plugs, Unshielded and Shielded 1. INTRODUCTION 1.1. Purpose Testing was performed on modular plugs to determine their conformance to the requirements
More informationHEAVY DUTY SWING-OUT VALVE
ISO 900 REGISTERED COMPANY HEAVY DUTY SWING-OUT VALVE 52 53 23 5 2 2 3 28 39 NOT USED WITH SZ HANDLE 2 NOT USED WITH SZ HANDLE 5 2 3 7 9 9 Premier Farnell Corporation. 20 All rights reserved. No portion
More informationNOTES ON SUBBASE AGGREGATE SPECIFICATION TNZ M/3. These notes must not be included in the Contract Documents.
TNZ M/3 Notes : 1986 NOTES ON SUBBASE AGGREGATE SPECIFICATION TNZ M/3 These notes must not be included in the Contract Documents. 1. INTRODUCTION There is no standard TNZ M/3 Specification for subbase
More informationPVC - WHITE PRESSURE FITTINGS L40P EFFECTIVE OCTOBER 1, 2018 REVISED PRODUCTS PRICE LIST
PRICE GROUP DESCRIPTION 01 SCH 40 PVC through 8 91 SCH 40 PVC 10" AND LARGER 96 CLASS 125 10 & 12 09 POOL AND SPA 14 LASCOTITE 15 ULTRAFIX REPAIR COUPLING DISCOUNT MULTIPLIER PRODUCTS PVC - WHITE PRESSURE
More informationReference Only Spec. No. JEFL243B 0003F-01 P 1/ 6
Spec. No. JEFL243B 0003F-01 P 1/ 6 DC Common Mode Choke Coil PLT09HN2003R0P1B Reference Specification 1. Scope This reference specification applies to DC Common Mode Choke Coil (PLT09H Series). 2. Part
More informationDISTRIBUTION CONDUCTOR STRINGING EQUIPMENT & TECHNIQUES
DISTRIBUTION CONDUCTOR STRINGING EQUIPMENT & TECHNIQUES FOR THE 21 ST CENTURY PRESENTED AT: SOUTHWEST TRAINING EXPO FEBRUARY, 2000 PRESENTED BY: JOHN R. WHITT SR. VICE PRESIDENT 1 When the decision is
More informationSpecifications Whitcomb Elementary School Demolition January 15, 2016
SECTION 31 2500 - EROSION CONTROL PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The provisions of the Contract Documents apply to the work of this Section. B. The Virginia Erosion and Sediment Control Handbook,
More informationAPPENDIX C STANTEC STANDARD OPERATING PROCEDURES
Site Investigation, Soil Management, and Capping Plan PAH Impacted Areas, St. Ann Center for Intergenerational Care, 2450 West North Avenue, Milwaukee, Wisconsin, DNR BRRTS Activity #02-41-56425, DNR FID
More informationNon-destructive testing of steel forgings- Part 1: Magnetic particle inspection (BS EN :1999)
Non-destructive testing of steel forgings- Part 1: Magnetic particle inspection (BS EN 10228-1:1999) 1 Scope This part of EN 10228 describes the method and acceptance criteria to be used for the magnetic
More informationCL-L102-C7D. 1. Scope of Application. These specifications apply to LED package, model CL-L102-C7D. 2. Part code
Specification sheet 1/10 1. Scope of Application These specifications apply to LED package, model. 2. Part code Series L102 : High power LED for general lighting Watt Class C7 : 7 watt class package Lighting
More informationConstruction Exits Vibration grids
Construction Exits Vibration grids SEDIMENT CONTROL TECHNIQUE Type 1 System Sheet Flow Sandy Soils Type 2 System Concentrated Flow Clayey Soils [1] Type 3 System Supplementary Trap Dispersive Soils [1]
More informationDesignation: NWI DIF Horizontal Hail impact Standard
Designation: NWI DIF Horizontal Hail impact Standard 2.1.2015 Standard Test Method for Materials attached to Vertical or Near Vertical Surfaces and Their Resistance to Horizontally Propelled Freezer Ice
More informationCulvert and Pipe Phasing
Culvert and Pipe Phasing Barney Blackburn, PE, CPESC, CPSWQ NCDOT Roadside Environmental Unit Soil & Water Engineering Section Supervisor NCDOT Culvert Phasing Process Hydraulics Unit: Culvert Survey Report
More informationSTANDARD: SPECIFICATION FOR PROTECTIVE ENCLOSURE AND CARRIER SYSTEMS USED TO TRANSPORT AND STORE ( INCH EUV RETICLES
Entegris Edit -SEMI Draft Document (10-11-2006 Revision) NEW STANDARD: SPECIFICATION FOR PROTECTIVE ENCLOSURE AND CARRIER SYSTEMS USED TO TRANSPORT AND STORE 6 INCH EUV RETICLES This specification draft
More informationTemperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company
Temperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company NEETRAC Project Number: 07-113 June 2007 A Research Center of the Georgia Institute of Technology Requested by: Dr. Colin McCullough
More informationA Fundamental Approach for an Investigation of Behavior Characteristics of the Vegetation Structures Using Seeded Sandbags
A Fundamental Approach for an Investigation of Behavior Characteristics of the Vegetation Structures Using Seeded Sandbags H. T. Kim & S. D. Yoo Dept. of Civil Engineering, Hongik University, Seoul, Korea.
More informationWACEL AGGREGATE LABORATORY TESTING TECHNICIAN
STUDY GUIDE WACEL AGGREGATE LABORATORY TESTING TECHNICIAN August 2016 Study Guide Aggregate Laboratory Testing General: An aggregate laboratory technician shall have sufficient training, education, and
More information5-25x56 PMII PSR With Double Turn
Page 1 of 20 5-25x56 PMII PSR 5-25x56 PMII PSR With Double Turn Page 3 of 20 1. Scope description... 5 1.1 Introduction... 5 1.2 Safety instructions... 5 2. Technical data... 6 2.1 General data... 6 2.2
More informationACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES
ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES (RPB-01) Approved by: Date: SECTION PAGE # 1.0 Scope 2.0 Definitions 3.0 References 4.0 Inspection
More informationStandard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate 1
Designation: D479 0 Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate This standard is issued under the fixed designation D479; the number
More informationNorthwest Hydro Tech Session_2017
STEP POTENTIAL FROM AN OPERATORS VIEW Presented by Fred WAC 296-45-005 ELECTRICAL WORKERS SAFETY RULES-FOREWORD. This chapter is not intended to be a complete job description nor is it expected that the
More informationRock & Aggregate Drop Inlet Protection
Rock & Aggregate Drop Inlet Protection SEDIMENT CONTROL TECHNIQUE Type 1 System Sheet Flow Sandy Soils Type 2 System [1] Concentrated Flow Clayey Soils Type 3 System Supplementary Trap Dispersive Soils
More informationS E C T I O N 1 2 P R O D U C T S E L E C T I O N G U I D E - H E L I C A L S C R E W P I L E F O U N D A T I O N S
1. P R O D U C T S E L E C T I O N G U I D E - H E L I C A L S C R E W P I L E F O U N D A T I O N S Helical foundation pile includes a lead and extension(s). The lead section is made of a central steel
More informationISSUED FOR CONSTRUCTION
PAGE No. DESCRIPTION 1 Cover Page 2 Overview Map 3 Western Road Plan View 4 Eastern Road Plan View West Road Profiles & Cross Sections 6-7 East Road Profiles 8- East Road Cross Sections 11-14 Campsite
More informationUSA Mexico
1.800.231.6074 USA 001.800.426.1447 Mexico 1.800.231.6074 USA 001.800.426.1447 Mexico 1.800.231.6074 USA 001.800.426.1447 Mexico 1.800.231.6074 USA 001.800.426.1447 Mexico 1.800.231.6074 USA 001.800.426.1447
More informationType 1 System Sheet Flow Sandy Soils Type 2 System Concentrated Flow Clayey Soils Type 3 System [1] Supplementary Trap Dispersive Soils
Sediment Weirs SEDIMENT CONTROL TECHNIQUE Type 1 System Sheet Flow Sandy Soils Type 2 System Concentrated Flow Clayey Soils Type 3 System [1] Supplementary Trap Dispersive Soils [1] Type 3 classification
More informationFIELD GUIDE FOR HORUS SCOPES
www.horusvision.com TM FIELD GUIDE FOR HORUS SCOPES Your Horus scope combines fine-quality optics, combat-proven hardware and the patented Horus reticle to deliver speed and accuracy for all shooters.
More informationSTATE OF NORTH CAROLINA D DEPARTMENT OF ADMINISTRATION February 1, 2013 PURCHASE AND CONTRACT DIVISION C March 8, 1995
STATE OF NORTH CAROLINA 6810-1D DEPARTMENT OF ADMINISTRATION February 1, 2013 PURCHASE AND CONTRACT DIVISION SUPERSEDING 6810-1C March 8, 1995 SPECIFICATION FOR CHEMICALS (This specification is released
More informationproduct manual H-3220A Benkelman Beam
05.12 product manual H-3220A Benkelman Beam General The H-3220A Benkelman Beam Apparatus is a convenient and accurate device used for measuring the deflection of flexible pavements under moving wheel
More informationConversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs
ISO 900 REGISTERED COMPANY HEAVY DUTY SWING-OUT VALVE 52 53 23 5 2 2 3 28 39 NOT USED WITH SZ HANDLE 2 NOT USED WITH SZ HANDLE 5 2 3 7 9 9 Premier Farnell Corporation. 20 All rights reserved. No portion
More informationRoHS. Specification CUD8AF1C. 서식 Rev: 00
Specification RoHS CUD8AF1C 1 [ Contents ] 1. Description 2. Outline dimensions 3. Characteristics of CUD8AF1C 4. Characteristic diagrams 5. Binning & Labeling 6. Reel packing 7. Recommended solder pad
More informationLaboratory Evaluation Report for: Dielectric Pipe Unions
American Society of Sanitary Engineering Seal (Certification) Program Laboratory Evaluation Report for: Dielectric Pipe Unions Tested under ASSE Standard 1079 Issued: September, 2005 Laboratory File Number
More informationSK Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS
SK Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS SAFETY... 2 INTRODUCTIONS... 5 TIPS ON PLOWING SNOW... 6 BOX PLOW ASSEMBLY PROCEDURE... 7 BOX PLOW BLADE ASSEMBLY DRAWING AND PARTS LIST...
More informationSTANDARD PROCEDURE: NWSP R2 (15) Polyacrylate Superabsorbent Powders Determination of the Particle Size Distribution by Sieve Fractionation
1. Scope STANDARD PROCEDURE: Polyacrylate Superabsorbent Powders Determination of the Particle Size Distribution by Sieve Fractionation This test method specifies a method for measuring particle size distributions
More information/2" Heavy Duty Swing-Out
Premier Farnell Corporation. 0 All rights reserved. No portion of this can be reproduced without the express written consent of Premier Farnell Corporation. ISO 900 REGISTERED COMPANY We will not be responsible
More informationChutes Part 5: Rock linings
Chutes Part 5: Rock linings DRAINAGE CONTROL TECHNIQUE Low Gradient Velocity Control Short-Term Steep Gradient Channel Lining Medium-Long Term Outlet Control [1] Soil Treatment Permanent [2] [1] Chutes
More informationWe Provide a Variety of Product Ranges Catering for an array of Usage Requirements.
We Provide a Variety of Product Ranges Catering for an array of Usage Requirements. Adhesive/FIXing Function ADSORBENT ADHESIVE SURFACE FUNCTION FUJICOPIAN's Functional Film About FIXFILM is a collective
More informationReference Only. Spec. No. JENF243G 0004G-01 P 1 / 12. Ferrite Bead Inductor BL02/BL03 Series
Spec. No. JENF243G 0004G-01 P 1 / 12 1. Scope Ferrite Bead Inductor B02/B03 Series Reference Specification This reference specification applies Ferrite Bead Inductor (Radial Type). 2. Part Numbering (Ex.)
More information